Kultur Dokumente
• Cooling 100 lbmol of Methanol from 150°F to 100°F using 1000 lbmol of Water at 50°F in a heat exchanger.
• Draw the simulation and review results
1
3
methanol
1
2
water
FLOWSHEET SUMMARY
ID Type Label Stream Numbers
1 HTXR 2 3 -1 -4
Stream Connections
Stream Equipment
From To
1 1
2 1
3 1
4 1
Calculation mode : Sequential
Flash algorithm : Normal
Equipment Calculation Sequence
1
No recycle loops in the flowsheet.
Overall Mass Balance lbmol/h lb/h
Input Output Input Output
Methanol 100.000 100.000 3204.200 3204.200
Water 1000.000 1000.000 18015.000 18015.000
Total 1100.000 1100.000 21219.199 21219.199
Overall Energy Balance MMBtu/h
Input Output
Feed Streams -131.923
Product Streams -131.923
Total Heating 0
Total Cooling 0
Power Added 0
Power Generated 0
Total -131.923 -131.923
COMPONENTS
ID # Name Formula
1 117 Methanol CH4O
2 62 Water H2O
THERMODYNAMICS
K-value model : NRTL
No correction for vapor fugacity
Enthalpy model : Latent Heat
Liquid density : Library