Sie sind auf Seite 1von 15

Design of Square Footing

by ENGR. JEROME B. MANSUETO

Parameters Value unit remarks

Column Width 400 mm


Column Length 400 mm
Dead Load 880 kN
Live Load 710 kN
*Soil Pressure
*Allowable Soil Pressure 235 kPa
*Effective Soil Pressure 206.75 kPa
*Depth of Footing 1.5 m
*Unit Weight of Soil 15.6 kN/m3
Unit Weight of Concrete 23.5 kN/m3
Steel Yield Strength 275 MPa
Concrete Compressive Strength 27.5 MPa
Main Bar Diameter 25 mm
Steel Covering 75 mm

Design output Value unit remarks

Length of Footing 2.8 m


Ultimate Soil Bearing Capacity 0.2796 MPa
**Depth of Footing based on
**Wide Beam Shear 343 mm
**Punching Shear 431 mm GOVERNS
Footing Thickness 543.5 mm OK
Ultimate Moment 563.68 kN-m
Minimum Steel Ratio 0.005091 GOVERNS
Actual Steel Ratio 0.004498
Area of Main Reinforcement 6144 mm2
Number of Reinforcement 13 bars BOTHWAYS
Development Length 515 mm
Furnished Ld 1125 mm OK
Dowel Requirement
Actual Bearing Strength 2192 kN
Permissible Bearing Strength 2992 kN
√A2/A1 7 USE 2
Permissible Bearing Strength 5984 kN DOWELS NOT NEEDED
Minimum Area of Dowel Required 800 mm2
Number of Column Bars Extended 2 bars
© 2019

remarks

remarks

GOVERNS
OK

GOVERNS

BOTHWAYS

OK

USE 2
DOWELS NOT NEEDED
Design of Rectangular Footing
by: ENGR JEROME B. MANSUETO

Parameters Value unit remarks

*Soil Pressure
*Allowable Soil Pressure 180 kPa
*Effective Soil Pressure 146.04 kPa
Steel Yield Strength 275 MPa
Concrete Compressive Strength 27.5 MPa
Unit Weight of Soil 15.2 kN/m3
Unit Weight of Concrete 24 kN/m3
Dead Load 1400 kN
Live Load 1850 kN
Dead Load Moment 450 kN-m
Live Load Moment 280 kN-m
Column Width 600 mm
Column Length 600 mm
Depth of Footing 1.8 m
Main Bar Diameter 28 mm
Steel Covering 75 mm
Footing Width 4.5 m
Initial Footing Thickness 750 mm

Design output Value unit remarks

Length of Footing 6.1 m OK


Ultimate Load 4640 kN
Ultimate Moment 988 kN-m
Ultimate Soil Pressure (Max) -204.44 kPa COMPRESSION
Ultimate Soil Pressure (Min) -133.64 kPa COMPRESSION
Investigate d Based on Wide Beam Shear
Effective Depth 633 mm
Soil Pressure at Distance d 179.87 kPa
Vu 1830.57 kPa
Vc 2489.62 kPa
ΦVc 1991.7 kPa OK
Steel Requirements
Maximum Steel Ratio 0.037158
Minimum Steel Ratio 0.005091
Along Long Direction
Minimum Steel Ratio 0.092106
Soil Pressure at Face of Column 172.53 kPa
Ultimate Moment 3786.97 kN-m
Ru 2.34 MPa
Actual Steel Ratio 0.008984
Area of Steel Reinforcement 25591 mm2
Number of Reinforcement 42 bars
Along Short Direction
Fu 2010.74 kN
Mu 1960.48 kN-m
Effective Depth 661 mm
Ru 0.82 MPa
Actual Steel Ratio 0.003037
Area of Steel Reinforcement 20528 mm2
Number of Reinforcement 34 bars
Distribution of Bars
Reinforcement at Center Bands 29 bars
Reinforcement at Outer Bands 3 bars
Other Reinforcement
Development Length 646 mm
Furnished Ld 1875 mm OK
Actual Bearing Strength 4640 kN
Permissible Bearing Strength 6732 kN
√A2/A1 8.74 kN USE 2
Permissible Bearing Strength 13464 kN DOWELS NOT NEEDED
Minimum Area of Dowel Needed 1800 mm2
Dowel Reinforcement 3 bars
ng
© 2019

remarks

remarks

OK

COMPRESSION
COMPRESSION

OK
OK

USE 2
DOWELS NOT NEEDED
Design of Wall Footing
by: ENGR JEROME B. MANSUETO

Parameters Value unit

Wall Thickness 300 mm


Wall Length 6 m
Axial Dead Load 20 kN/m
Axial Live Load 15 kN/m
Horizontal Dead Load 30 kN/m
Horizontal Live Load 20 kN/m

Distance of Horizontal Loads to Column Base 1.04 m

*Soil Pressure
*Allowable Soil Pressure 200 kPa
*Effective Soil Pressure 178.915 kPa
Depth of Footing 1.2 m
Unit Weight of Soil 16 kN/m3
Unit Weight of Concrete 23.54 kN/m3
Concrete Compressive Strength 27.6 MPa
Main Bar Diameter 25 mm
Main Bar Yield Strength 275 MPa
Temperature Bar Diameter 10 mm
Temperature Bar Yield Strength 230 MPa
Steel Covering 75 mm
Initial Footing Thickness 250 mm

Design output Value unit

Length of Footing 1.5 m


Ultimate Moment 424.32 kN-m
Ultimate Soil Pressure (Max) 220.59 kPa
Ultimate Soil Pressure (Min) -156.59 kPa
Check Adequacy of d for Wide Beam Shear
Effective Depth 175 mm
Vu 426.25 kN
Vc 919.38 kN
ΦVc 735.51 kN
Steel Requirements
Critical Moment 156.77 kN-m
Ru 0.95 MPa
Minimum Steel Ratio 0.005091
Maximum Steel Ratio 0.037293
Actual Steel Ratio 0.003528
Area of Main Reinforcement 5346 mm2
Number of Main Reinforcement 11 bars
Spacing of Main Reinforcement 550 mm
Area of Temperature Reinforcement 750 mm2
Number of Temperature Reinforcement 10 bars
Spacing of Temperature Reinforcement 141 mm
Development Length 430 mm
Furnished Ld 525 mm
Actual Bearing Strength 288 kN
Permissible Bearing Strength 33782.4 kN
√A2/A1 2.24 kN
Permissible Bearing Strength 67564.8 kN
Minimum Area of Dowel Needed 9000 mm2
Dowel Reinforcement 19 bars
© 2019

remarks

remarks

ar

OK
OK

USE 2
DOWELS NOT NEEDED
Design of Combined Footing (on edge)
by: ENGR JEROME B. MANSUETO

Parameters Value unit remarks

Column 1
Length 400 mm
Width 400 mm
Dead Load 650 kN
Live Load 940 kN
Column 2
Length 500 mm
Width 500 mm
Dead Load 1120 kN
Live Load 1430 kN
Distance Between Columns 4 m
Depth of Footing 2 m
Unit Weight of Soil 17.2 kN/m3
Unit Weight of Concrete 23.5 kN/m3
Concrete Compressive Strength 27.5 MPa
Main Bar Diameter 25 mm
Main Bar Yield Strength 345 MPa
Temperature Bar Diameter 16 mm
Temperature Bar Yield Strength 275 MPa
Steel Covering 75 mm
Allowable Soil Pressure 290 kPa
Trial Effective Depth 680 mm

Design output Value unit remarks

Length of Footing 5.33 m


Thickness of Footing 768 mm
Effective Soil Pressure 250.77 kN/m3
Width of Footing 3.1 m
Ultimate Load 5916 kN
Ultimate Soil Pressure 358.05 kN
Check d for Punching Shear
Column 1
bo 2560 mm
Vu 1997.85 kN
Vc 3042.95 kN
ΦVc 2434.36 kN OK
Column 2
bo 4720 mm
Vu 3133.46 kN
Vc 5610.43 kN
ΦVc 4488.35 kN OK
Check d for Wide Beam Shear
Acol1 3.35 mm2
Vcol1 2366.4 kN
Acol2 6.39 mm2
Vcol2 1344.07 kN
Vumax 1345.5 kN
Vc 1842.41 kN
ΦVc 1473.93 kN OK
Reinforcements in Long Direction
Maximum Steel Ratio 0.036566
Minimum Steel Ratio 0.004058
Point 1: At Face of Column 1
Moment -368.01 kN-m
Ru 0.285258 MPa
Actual Steel Ratio 0.000832
Area of Main Reinforcement 8555 mm2
Number of Main Reinforcement 18 bars
Location TOP
Point 2: At Point of Maximum Moment
Moment -1893.38 kN-m
Ru 1.467628 MPa
Actual Steel Ratio 0.004397
Area of Main Reinforcement 9269 mm2
Number of Main Reinforcement 19 bars
Location TOP
Point 3: At Left Face of Column 2
Moment 93.53 kN-m
Ru 0.072499 MPa
Actual Steel Ratio 0.000211
Area of Main Reinforcement 8555 mm2
Number of Main Reinforcement 18 bars
Location BOTTOM
edge)
© 2019

remarks

remarks

OK
OK

OK
P1 1590
P2 2550
x1 0.2
x2 4.2
P 4140
hsoilabovef 1.232
Pu1 2284
Pu2 3632
Vu1 -1085.249
Vu2 1345.493
w1 5710 0.4
w2 7264 0.5
w3 1109.955 3.55
SD1 -1840.018
SD3 2100.322
SD4 -976.7003
SDx 1.658
M1 -368.0036
M2 -1893.379
M3 93.52633
M4
pc1 0.012279 0.004058
pc2 0.064892 0.004397
pc3 0.003106 0.004058
pc4