Sie sind auf Seite 1von 2

Cyclone

Name B1
Property method IDEAL
Henry's component list ID
Electrolyte chemistry ID
Use true species approach for electrolytes YES
Free-water phase properties method STEAM-TA
Water solubility method 3
Model CYCLONE
Mode SIMULATION
Calculation method LEITH-LICHT
Type USER
Fraction of solids to solid outlet
Fraction of vapor to vapor outlet
Vapor load of solid outlet stream
Solid load of vapor outlet stream
Characteristic of separation VELOCITY
Separation sharpness 0
Offset of fines 0
Vane constant 16
Wall friction coefficient 0.0075
Constant D 3
Constant Kg 0.025
Consider secondary flow NO
Design pressure drop [bar]
Number of cyclones 1
Separation efficiency 0.895
Maximum pressure drop [in-water-60F] 10
Maximum number of cyclones 1
Length of cylinder [in] 40
Length of cone section [in] 15
Length of overflow [in] 5
Diameter of overflow [in] 5
Diameter of underflow [in] 3.75
Number of gas turns 5.5
Inlet configuration
Height of inlet [in] 5
Width of inlet [in] 2
Diameter of inlet [meter]
Angle of inlet
Blade type STRAIGHT
Angle of blade
Length of cylinder for user-spec ratios
Diameter of overflow for user-spec ratios
Length of cone section for user-spec ratios
Diameter of underflow for user-spec ratios
Length of overflow for user-spec ratios
Height of inlet for user-spec ratios
Width of inlet for user-spec ratios
Diameter of inlet for user-spec ratios
Number of gas turns for user-spec ratios 5.5
Maximum diameter for user-spec ratios [meter] 5
Critical solids loading [gm/l] 0.001
Pre-exponent for correcting pressure drop
Exponent for correcting pressure drop
Exponent for correcting efficiency
Calculated fraction of solids to solid outlet
Calculated fraction of vapor to vapor outlet
Calculated solid load of vapor outlet
Calculated vapor load of solid outlet
Calculated D50 of separation curve
Type of cyclone 2
Calculated number of cyclones 1
Calculated pressure drop [bar] 0.0007638912
Calculated diameter of cylinder [meter] 0.254
Calculated efficiency 0.903511327
Calculated length of vortex [meter] 0.62930989
Calculated length of cylinder [meter] 1.016
Calculated length of cone [meter] 0.381
Calculated diameter of gas outlet [meter] 0.127
Calculated diameter of gas inlet
Calculated length of gas outlet [meter] 0.127
Calculated width of gas inlet [meter] 0.0508
Calculated height of gas inlet [meter] 0.127
Calculated diameter of solids outlet [meter] 0.09525
Calculated number of gas turns 5.5
Calculated inlet/saltation velocity ratio 1.54108032
Total feed stream CO2e flow [kg/hr] 2676.50066
Total product stream CO2e flow [kg/hr] 2676.50066
Net stream CO2e production [kg/hr] 0