Sie sind auf Seite 1von 23

Cathodic Protection Systems

About Us

✔ 25 years of cathodic protection experience


✔ production base:

“Anod” Oil and Gas Equipment Plant;

“Raduga” Electronic Corporation;

"Eurasia-Story” Building Department;
✔ our own engineering center
✔ well-developed logistics structure in 11 countries and 85 regions
of Russia
✔ all types of active cathodic protection
✔ “turn-key" projects:

research and design,

full production cycle and delivery,

installation and service.
About Us

Production area -
12000 sq. m.

Modern machine park

Highly qualified staff

Modern labor
organization
built on "Kaizen"
principles
Application Fields

✔ oil and gas facilities;


✔ marine infrastructure objects;
✔ atomic industry;
✔ Housing and Utilities sector;
✔ railways.
Produced equipment
(more than 200 items)

AZP-RA AZP-RA-U

IPKZ-MS-RA IPKZ-E-RA
PM-U
(48/96)

ENES-4M
ENES-1
IPKZ-M-RA-TC IPKZ-RA UDP-300 KIP-PSS
Pulse Transformers


Rated output power, kW — from 0.3 to 5

Rated output current, A — from 6.3 to 100

Rated output voltage, V — 48/96

Supply voltage, V — 220 22
IPKZ-M-RA

Output voltage ripple, %, max — 1

Regulation range of output current and voltage,% — from 0 to 100

Measuring range of polarization and total potentials, V — from -4.5 to +4.5

The range of setting the total potential, V — from -3.5 to -0.5

Energy conversion efficiency in rated mode,%, min – 90

Power factor, min – 0,95

Service life, years, min – 15

A possibility of 100% backup of power modules

Ingress protection rating IEC 60529 – IP34

Climatic Design - medium low temperature version
IPKZ-E-RA
Test Points

Parameter KIP.PSS-1 KIP.PSS-2 KIP.PSS-3


Height, cm 240-270 240-270 240-270
Profile section, mm
Δ 120 Δ 180 ◊ 205
Section of conductors, m2, max
— power 35 35 35
— measuring 6 6 6
Rate of penetration into the 700 700 700
ground,
mm
Ingress Protection Rating IEC IP 44 IP 44 IP 44
60529
Service life, years, min
30 30 30

Test point can be equipped with additional cathodic protection. KIP.PSS


Reference Electrodes

Показатели
Parameter ЭНЕС-1
ENES-1 ЭНЕС-4М
ENES-4M ЭНЕС-5М
ENES-5M
Внутреннее
Internal электрическое
electrical resistance 0,1 - 2,5 1,0 0,5
сопротивление,
kOhm(kΩ), max), max кОм, не ENES-1
более
Переходноеelectrical
Transitional электрическое 15,0 10,0 10,0
сопротивление,
resistance, kOhmкОм
Потенциал
Potential withпоrespect
отношению
to theк 120 100 120
хлорсеребряному
silver chloride electrode, mV
электроду, мВ
Количество
The электролита,
electrolyte filling amount 120 800 260
заливаемого
into в корпус,
the casing, ml мл
Маркаof
Model кабель-выводов
output cable ПВ З*1,5 КГВЭВнг 2х4 ПВ 3*1,5
Установленный
Service срокmin
life, years, 15 25 3 ENES-4M
службы, лет, не менее

When implementing ENES — 4М the housing can be in any position.


The best is the position of the membrane upwards, which increases
the service life.
ENES-5M
Polymeric Anodes

Parameter AZP- AZP- AZP- AZP-


RA RA-U RA-GU RA-GS
Removable current load, A up to 5,0

Rated current load, A 2,0 - 3,0

Anodic dissolution rate, kg / 0,01…0,06


A * year

Overall electrode dimensions 1500х50 1810х205 Maximum Maximum


(Lхd), mmхd), mm amount of amount of
AZP-RA – 16 AZP-RA – 32

Electrode weight, kg, max 5,0 60 - -


Model of cable output KGN-HL EHZ 1х10 (1х6)
Model of backbone cable KGN-HL EHZ 1х35
Operating temperature, degree from 0 to +60
AZP-RA AZP-RA-U
C

Service life, years, min 35


Climatic Design О5
Comparative table of Polymeric and High Silicon
Iron Anodes

Ргр 10 Ohm 60 Ohm 150 Ohm

Distinctive feature Polymeric 14 80 83


of AZP-RA
- Maximum effect when High Silicon Iron 12 126 157
working in soils with a
specific electrical
resistance of more than 30 High Silicon Iron
Ohm

- Works perfectly in high-


resistance soils — 300 –
500 Ohm Polymeric
Flexible Power Cable for Cathodic Protection (KGN EHZ)

Main advantages of KGN EHZ:

● Service life, years, min - 35 years;


● 5th class of flexibility of the core;
● Insulation material — heat-resistant alkyndium elastomer;
● Shell material — oil and petrol resistant thermoplastic
elastomer;
● Operating conditions — from -30 to +50 °C;
● Increased endurance;
● Increased oil and petrol resistance;
● Versatility: can be used with all ECP devices.

Nominal section of main cable cores – 0,75 ...... 400 sq.


mm.
Vessel Cathodic Protection Complex

ESHS-S-RA

the work of the operator with the


data of the station IPKZ-MC_RA  IPKZ-MC_RA 

IPKZ-MC_RA 

Sacrificial anode Reference electrode


anode of
vessel hulls
protection
Cathodic Protection of Seaports Pile Foundation

IPKZ-M-RA-TC

Zinc reference electrode


Titanium anode
Cathodic Protection of Seaports Pile Foundation

PAKM-40

P-BTTC
Galvanic Anodes Protection

We produce the whole range of Al, Mg, Zn galvanic anodes according to GOST,
specifications

Interflange galvanic
anodes P-KLA-15 P-KOM-3a UPBA

Vessel galvanic P-ROM-0,8 P-NOA-5 P-ROM-7


anodes
Practical tests of ЭХЗ (Taman)Taman)
Results of the practical tests of cathodic protection (Taman)Taman)

Potential value Schedule of changes in the protection


potential of supports

Support potential value


Row 2 Row 3
natural potential relative to the electrode

natural potential relative to the electrode

natural potential relative to the electrode

natural potential relative to the electrode


Equipment Sertification
Remote control cathodic protection system in
real-time


potential (total, polarization);

output current;

output voltage;

system voltage;

stabilization mode;

installation by stabilization parameter;

readings of metering devices;

working time;

protection time of the constructure;

deactivating/activating of the device;

local/remote mode;

backup/primary station;

unauthorized access;

connection with the control unit;

emergency situation (door condition, output cable break, ES cable break, short circuit,
network overvoltage).
The Effect of the Complex Usage of Cathodic
Crotection Systems

Increased safety

Visualization and
Reduced maintenance automation of
costs operating cathodic
protection system
Decreasing of the time processes
loses

The effect of the introduction was more than 6 million rubles


(Taman)100 000 USD)
Maintenance costs decreased by 3 times
Patents
More than 60 patents registered
Our Clients
Thank you for your
attention!

pss.global