Sie sind auf Seite 1von 44
Chloropicrin No.233 =< CG fe FE oo DS Scale range (0.}40p0m Measuring range (0.045-22ppm Colour ehange White Yetow Sheltie year 1,2-Dichloroethane No.232 < Got [oe eS Scale range TASpom Measuring range 38pm Colour change | __ White Pale purple i Tyear Snel Ife (Retrigerated storage) PREPARATION A.NOTE When the handle is unlocked, be sure to guide it back gradually by applying a little resistance. Otherwise, the handle will spring back due to the vacuum in the pump cylinder and possibly damage internal parts. Detector Tube Single tube (Example: No.1HH Carbon Monoxide) Inspecting the pump model GV-100 before measurement (air leak check) (1) Confirm that the intet clamping nut is fimly tightened (2) After confirming that the pump handle is fully in (therefore, the guide line on the pump shaft is not seen) insert a fresh unbroken detector tube into the (8) Align the guide mark (recline) on the back plate and the ‘guide mark (4.100) on the handle, (4) Pull out the handle fully along the red guide line on the ump shaft tothe lock position, and wait 1 minute. (6) Unlock the handle by turning it more than 1/4 turns and guide it back gradually (6) Confirm the handle returns to the intial position and the guide line on the pumo shaft is not seen. ANOTE The above air leak check feature in accordance with EN1231,4.2. Twin tube (Example: No.1631 Ethylene Oxide) totem — EF] coPrpacenve Se (1 Fresh be cewtatve ETT evan umber connecter (2) Prepares be = OPERATION \d Simple and accurate measurements with the Gastec standard detector tube system a) Insert the detector tub end straight into the tube tip leaker of the Pump, bb) Rotate the detector tube so that the diamond cutter of the tube tip breaker scratches the surface of the tube end, ©) Hold the detector tube firmly near the tube tip breaker and bend the tube toward you to break the tube tip. ) Confirm the pump handle is fuly pushed in therefore, the guide ling on the pump shatt is not seen). Then insert the detector tube into the rubber inlet of the Pump with the arrow ( p) onthe tube pointing toward the pump. ©) Align the guide mark (red line) on the back plate and the guide mark (4100 or 450 depending on the detector tube) on the hundle. {). Direct the tube end to the point of measurement and pull out the handle fully (for 100mL sampling) or halfway (for SOmL sampling) along the guid tine to the lock position. 9) Wait until the sampling time has elapsed. The completion of the sampling of 100mL or S0mL can be confirmed by the following two options i) Use the builtin tlow finish indicator il) Use handle play function For details, see the instruction manual provided with the pump. How to read the detector tube (a) The end of the colour change layer flat: Read the value at the end of the layer. In this example, the reading should be 5%. (b)The end of the colour change layer slanted: Read the value in the midi of the slant. In this exaggerated example, the reading should be 5%. (¢) The demarcation of the colour change layer pale: Read the value in the middle between the dark layer end and the pale layer end. In this exaggerated example, the reading should be 5% A NOTE Read instructions for your Gastec detector tube and model GV- 1008 carefully

Das könnte Ihnen auch gefallen