Actuator-Sensor-Interface

I/O Modules for Operation in the Field (IP 65/67)


Pneumatic I/O modules IP 65/67 – K60
Actuator-Sensor-Interface

■ Overview
A glance at a wide range of ap- decentralisation also seems at- cylinder in the form of sensor • K60 pneumatic compact
plications reveals that valve tractive here: Just as the load signals are now combined in modules (4 digital inputs / 2
units are being increasingly feeder (for motor starters) is lo- one I/O module. pneumatic outputs designed
connected to the fieldbus. This cated directly alongside the as 2 x 4/2-way monostable or
In the Siemens product spec-
is always an advantage when a motor, the valve can also be di- bistable valves)
trum, two pneumatic series are
large number of pneumatic rectly mounted on the cylinder
offered with integral 3/2-way • Pneumatic application mod-
loads are implemented in a in the form of an AS-i pneumatic
and 4/2-way valves: ules (up to 4 digital inputs / 2
central configuration. module, i. e. the valve as a
pneumatic outputs designed
pneumatic output and the posi-
When the cylinders are lying in- as 2 x 3/2-way monostable
tion feedback from the
dividually, for example, on a valves)
conveyor belt, the idea of

Monostable compact modules


The monostable, pneumatic with a common pressurised air if pressures between 90 % vac- 100 %. An internal control loop
compact modules are Series supply and separately guided uum and 2 bar are to be con- in the slave electronics causes
K60 modules. They have four exhaust air. nected in the main control sec- the holding power of both pilot
digital inputs for connecting the tion. This separate pilot supply valves to be reduced to such a
For pressures under 3 bar, all
position feedback signals (e. g. can only be connected by level that the conditions of
variants of the pneumatic com-
cylinder switches) and two switching from internal supply Class T6 are met even at maxi-
pact module feature the "active
pneumatic outputs. to external supply by plugging mum switching frequency at an
by push" function as standard:
in the hose. ambient temperature of +55 °C.
The two pneumatic outputs are Via a separate 4 mm plug-in
The pneumatic module can be
implemented using two precon- valve, the pilot valves can be Both pneumatic outputs can al-
implemented in Ex Zones
trolled 4/2-way valves (90 % supplied separately with com- so be operated manually via
11 and 2.
vacuum up to 8 bar, 550 Nl/min) pressed air of at least 3 bar separate slides. The On time is

Monostable 4/2-way valve Circuit diagram

Outputs not switched L+In2 L- In1 L+n.c L- In2 L+In2 L- In1 L+n.c L- In2 Outputs switched
Manual Actuator-
control connection +IN1- +IN2- +IN3- +IN4-
B 2 4
+
AS-Inter-
P R S7.F
NSA00062a 1 3
face
Magnet -
coil
Air intake 3 Vent OUT1 OUT2

D0 = 0 D0 = 0 NSA00063b D0 = 1 D0 = 1

Notes on the monostable Example: Operating a double- • If bit D0 is set to 0 again, the Note: the valve can also be
4/2-way valve: action cylinder via the D0 out- valve switches back again switched using emergency
put of a pneumatic compact and the piston rod retracts. manual. The valve must, how-
• The monostable 4/2-way
module with monostable ever, be in the standard posi-
valve is mainly used to con- • In the event of power failure,
4/2-way valves: tion because the precontrol
trol double-action pneumatic the monostable valve is reset
valve and manual operation
loads (e. g. double-action • If bit D0 for output 1 is set to to the initial position (D0 = 0)
are implemented in parallel to
cylinders). The force in the ef- 0, the left cylinder chamber is due to the spring reset.
allow fault-free operation at all
fective direction and the re- deaerated and the right cylin-
• Both integrated 4/2-way times.
turn stroke take place pneu- der chamber is aerated. The
valves can be switched inde-
matically. piston rod is retracted.
pendently of each other.
• Important: 4/2-way and 5/2- • If bit D0 is set to 1, the inte-
way valves perform the same grated valve changes over.
function. They are inter- The left cylinder chamber is
changeable. aerated and the right cylinder
chamber is deaerated. The
piston rod travels outwards.

1/74 Siemens NS K · 2002


Actuator-Sensor-Interface
I/O Modules for Operation in the Field (IP 65/67)
Pneumatic I/O modules IP 65/67 – K60
Actuator-Sensor-Interface

■ Overview
Bistable compact modules
For applications in which it is In the bistable compact mod- Two output signals are neces- In the event of the compressed
necessary for a valve to retain ule, a single bistable pilot valve sary for activating a bistable pi- air supply failing in addition to
its current position in the event (precontrol valve) is used. In lot valve (OUT1 and OUT2 or the electrical supply, no holding
of power supply failure, a bista- contrast to other bistable solu- OUT3 and OUT4), e.g. OUT1 is power can be applied.
ble valve must be used. tions in which a bistable func- used to set the valve and OUT2
Installations must therefore
tion is implemented using a pi- is used to reset the valve.
The pneumatic compact mod- always be designed to en-
lot valve with two systems of
ule with a bistable function was A prerequisite for implementing sure that plant safety is al-
magnets, the compact module
developed to ensure that this a bistable valve is therefore that ways assured, i.e. that a pres-
only requires a bistable precon-
function was also available in a in the event of power failure, the sure drop, pressure failure or
trol valve with one system of
pneumatic AS-i module. The previously achieved position is loss of a vacuum will not
magnets.
electrical and pneumatic speci- maintained, i.e. that the proba- cause any danger to persons
fications of this module largely Changeover between the two bility of pressure failure is less or the environment.
correspond to the monostable possible stable states of a bist- than the probability of power
version already described. The able valve is performed by re- failure.
only differences lie in the pneu- versing the polarity of the mag-
matic function and in the electri- nets, i.e. the valve is held in the
cal control: respective position with just one
system of magnets.

Bistable 4/2-way valve Circuit diagram

Outputs not switched L+In2 L- In1 L+n.c L- In2 L+In2 L- In1 L+ n.c L- In2 Outputs switched
Manual Aktuator
control connection +IN1- +IN2- +IN3- +IN4-
2 4
+
AS-Inter-
S7.F
NSA00064b 1 3 face
Magnet -
coil
Air
Vent OUT1/OUT2 OUT3/OUT4
bistable intake
precontrol
valve

D0 = 0 D2 = 0 NSA00065 D0 = 1 (pulse) D2 = 1 (pulse)


D1 = 1 (pulse) D3 = 1 (pulse) D1 = 0 D2 = 1

Notes on the bistable Example: Operating a double- The output bits only need to be Both integrated 4/2-way valves
4/2-way valve: action cylinder via the D0 and set for a short period (5 ms) can be switched independent-
D1 output of a pneumatic com- and the valve switches to a ly of each other.
The bistable 4/2-way valve is
pact module with bistable safe position. The valve is reset
mainly used to control double- Note: the valve can also be
4/2-way valves: by setting the opposite output
action pneumatic loads (e. g. switched using emergency
bits.
double-action linear and swivel • If bit D0 is set to 1, the inte- manual. The valve must, how-
cylinders). The bistable func- grated valve changes over. Under no circumstances must ever, be in the standard posi-
tion is necessary when the The left cylinder chamber is the two outputs D0 and D1 be tion because the precontrol
valve is required to maintain its aerated and the right cylinder switched at the same time, as valve and manual operation
current position following a chamber is deaerated. The with any bistable valve, other- are implemented in parallel to
power failure. piston rod travels outwards. wise an undefinable position allow fault-free operation at all
will be achieved. times.
• If bit D1 is set to 1, the valve
switches back again, the left In the event of power failure,
cylinder chamber is deaerat- the bistable valve remains in
ed and the right cylinder the previously achieved posi-
chamber is aerated. The pis- tion.
ton rod is retracted.

Siemens NS K · 2002 1/75


Actuator-Sensor-Interface
I/O Modules for Operation in the Field (IP 65/67)
Pneumatic I/O modules IP 65/67 – K60

■ Selection and ordering data


Design Short code DT Order No. Price PG Pack

Unit Unit
3RK1 408-0MT00-0CA0 4 PNP inputs
2 outputs, pneumatic 1)
monostable
Y-II assignment
• Exhaust air via sintered filter 4I/2OP-MS } 3RK1 408-0MT00-0CA0 131 1
• Exhaust air via plug-in 4I/2OP-MG A 3RK1 408-0MT01-0CA0 131 1
connector
• Exhaust air via sintered filter 4I/2OP-MSE A 3RK1 408-1MT00-0CA0 131 1
Valve supply via U aux
• Exhaust air via plug-in connector 4I/2OP-MGE B 3RK1 408-1MT01-0CA0 131 1
nsa0244b Valve supply via U aux
4 PNP inputs
3RK1 408-0CT00-0CA0 2 outputs, pneumatic 1)
bistable
Y-II assignment
• Exhaust air via sintered filter 4I/2OP-BS A 3RK1 408-0CT00-0CA0 131 1
• Exhaust air via plug-in 4I/2OP-BG B 3RK1 408-0CT01-0CA0 131 1
connector
• Exhaust air via sintered filter 4I/2OP-BSE A 3RK1 408-1CT00-0CA0 131 1
Valve supply via U aux
• Exhaust air via sintered filter 4I/2OP-BGE B 3RK1 408-1CT01-0CA0 131 1
Valve supply via U aux
nsa0245b

■ Dimension drawings
Compact module, pneumatic

60 55
152

NSA00182a

Side view with


NSA00181

mounting plate
3RK1 901-0CA00

1) Modules supplied without mounting plate.

1/76 Siemens NS K · 2002


Actuator-Sensor-Interface
I/O Modules for Operation in the Field (IP 65/67)
Pneumatic I/O modules IP 65/67 – K60

■ Technical data
Exhaust air via sintered Exhaust air via plug-in Exhaust air via sin- Exhaust air via plug-in
filter connector tered filter connector
4 PNP inputs 4 PNP inputs 4 PNP inputs 4 PNP inputs
2 pneumatic outputs 2 pneumatic outputs 2 pneumatic outputs 2 pneumatic outputs
monostable monostable monostable monostable
Valve supply via Uaux Valve supply via Uaux

Y-II assignment Y-II assignment Y-II assignment Y-II assignment

3RK1 408-0MT00-0CA0 3RK1 408-0MT01-0CA0 3RK1 408-1MT00-0CA0 3RK1 408-1MT01-0CA0


Slave type Standard slaves
Operational voltage in accordance with AS- 29.5 ... 31.6
Interface specification in V
Total current input in mA <200
Input connection PNP
Inputs
• Sensor supply via AS-Interface Short-circuit-proof
• Sensors 2- and 3-wire
• Voltage range in V 20 ... 30
• Load rating in mA 100 200
for all inputs
• Socket assignment PIN 1 = Sensor supply L+
(Y-II assignment of input sockets: PIN 3 = Sensor supply L-
See Section Compact modules/ PIN 4 = Data input I
Terminal assignment) PIN 2 = Data input II
PIN 5 = Earth connection
Outputs (pneumatic)
• Number of 4/2-way valves (monostable) 2
• Nominal diameter of seat valves in mm 5
Hose plug-in connector Legris 3000 / 8 mm
Operating pressure range in bar 8 ... 3
Extended operating pressure range on appli- 90 % vacuum up to 8 bar
cation of control air (min. 3 bar)
Flow rate at 6/5 bar in Nl/min 550
Compressed-air consistency filtered (40 µm); oiled or not oiled
Watchdog yes
AS-Interface profile 7.F
I/O configuration 7
ID code F
Assignment of data bits
• Socket 1 PIN4 = IN1(D0) / PIN2 = IN2(D1)
• Socket 2 PIN4 = IN2 (D1)
• Socket 3 PIN4 = IN3(D2) / PIN2 = IN4(D3)
• Socket 4 PIN4 = IN4 (D3)
• Valve 1 OUT1 (D0)
• Valve 2 OUT2 (D1)
AS-Interface certificate yes
Approvals UL, CSA
Protection IP 65 IP 67 IP 65 IP 67
Ambient temperature in °C 0 ... +55
Storage temperature in °C –5 ... +70
Number of input sockets 4
Status indications
• Switching status yellow LED
• AS-Interface green LED
• FAULT red LED
• AUX PWR – green LED
Connection Via contact pin and 3RK1 901-0CA00 mounting plate (mounting plate must be ordered separately)
Configuration note Two output bits (D0 and D1) are required for controlling the two integrated monostable valves.

Note – To supply the output circuit, an external supplemen-


tary supply (AUX POWER) of
DC 20 to 30 V is necessary. The supplementary sup-
ply must comply with VDE 0106 (PELV), safety
class III.

Siemens NS K · 2002 1/77


Actuator-Sensor-Interface
I/O Modules for Operation in the Field (IP 65/67)
Pneumatic I/O modules IP 65/67 – K60

■ Technical data
Exhaust air via sintered Exhaust air via plug-in Exhaust air via sin- Exhaust air via plug-in
filter connector tered filter connector
4 PNP inputs 4 PNP inputs 4 PNP inputs 4 PNP inputs
2 pneumatic outputs 2 pneumatic outputs 2 pneumatic outputs 2 pneumatic outputs
bistable bistable bistable bistable
Valve supply via U aux Valve supply via Uaux

Y-II assignment Y-II assignment Y-II assignment Y-II assignment

3RK1 408-0CT00-0CA0 3RK1 408-0CT01-0CA0 3RK1 408-1CT00-0CA0 3RK1 408-1CT01-0CA0


Slave type Standard slaves
Operational voltage in accordance with AS- 29.5 ... 31.6
Interface specification in V
Total current input in mA <200
Input connection PNP
Inputs
• Sensor supply via AS-Interface Short-circuit-proof
• Sensors 2- and 3-wire
• Voltage range in V 20 ... 30
• Load rating for inputs in mA 100 200
• Socket assignment PIN 1 = Sensor supply L+
(Y-II assignment of input sockets: PIN 3 = Sensor supply L-
See Section Compact modules/ PIN 4 = Data input I
Terminal assignment) PIN 2 = Data input II
PIN 5 = Earth connection
Outputs (pneumatic)
• Number of 4/2-way valves (bistable) 2
• Nominal diameter of seat valves in mm 5
Hose plug-in connector Legris 3000 / 8 mm
Operating pressure range in bar 8 ... 3
Extended operating pressure range on appli- 90 % vacuum up to 8 bar
cation of control air (min. 3 bar)
Flow rate at 6/5 bar in Nl/min 550
Compressed-air consistency filtered (40 µm); oiled or not oiled
Watchdog yes
AS-Interface profile 7.F
I/O configuration 7
ID code F
Assignment of data bits
• Socket 1 PIN4 = IN1(D0) / PIN2 = IN2(D1)
• Socket 2 PIN4 = IN2 (D1)
• Socket 3 PIN4 = IN3(D2) / PIN2 = IN4(D3)
• Socket 4 PIN4 = IN4 (D3)
• Valve 1 OUT1 (D0) / OUT2 (D1)
• Valve 2 OUT3 (D2) / OUT4 (D3)
AS-Interface certificate yes
Approvals UL, CSA
Protection IP 65 IP 67 IP 65 IP 67
Ambient temperature in °C 0 ... +55
Storage temperature in °C –5 ... +70
Number of input sockets 4
Status indications
• Switching status yellow LED
• AS-Interface green LED
• FAULT red LED
• AUX PWR – green LED
Connection Via contact pin and 3RK1 901-0CA00 mounting plate (mounting plate must be ordered separately)
Configuration note Four output bits (D0, D1, D2, D3) are required for controlling the two integrated bistable valves.

Note – To supply the output circuit, an external supplemen-


tary supply (AUX POWER) of
DC 20 to 30 V is necessary. The supplementary sup-
ply must comply with VDE 0106 (PELV), safety
class III.

1/78 Siemens NS K · 2002