Sie sind auf Seite 1von 10

Description Lighting distribution 0

Canalis KDP 20 A

Uncoiler kit

Allows easy setting up of the KDP trunking by allowing the cable reel to be rolled. It can also be used with all standard roller type uncoilers.
It clips onto the packing spools and can be removed for re-use.

2 1 Uncoiler kit (8 parts)


2 Packing spools
3 Cable uncoiler (not supplied)

Run components

Carries the current and supplies the lighting units.

2 1

The run components consist of:


1 A flat ribbon cable conforming to standard IEC 60502-1 with 3 or 5 x 2.5 mm2 conductors, including one protective conductor. The copper
conductors are tinned to protect them against corrosion.
Canalis KDP is available in 24 or 192 metre reels. The 192 metre reel contains eight spools, which are clipped together and each contains
24 metres of cable. For easy installation and in order to be able to use the uncoiler kit (see above), it is recommended that KDP be supplied
in multiples of 24 metres.
# As an option (code X), a halogen-free version of KDP is available.

2 Tap-off contact studs, positioned at 1.5 or 3 metre intervals.


These are factory fitted, can receive all tap-off units in the KBA and KBB ranges and ensure electrical connection of the tap-off units.
The degree of protection of the assembly is IP 54.
All the insulating and plastic materials used have increased fire resistance : resistance to incandescent wire test conforming to IEC 695-2-1 :
- 850 °C for parts in contact with live components,
- 650 °C for other parts.
KDP is certified to be non flame-propagating, in accordance with standard IEC 60331-1

The whole system conforms to standard IEC 60439-2

Feed units and end covers

To supply a Canalis KDP run After having stripped the KDP cable, the connection is
made by means of a screw terminal for copper cable
with a maximum c.s.a. of 4 mm 2.
These components are fitted with a PG 16 cable gland.
They are locked in the closed position by a screw. They
can be used to supply the run from the RH or LH side
and for butt-jointing two KDP runs. Each feed unit is
supplied with an end cover for the opposite end of the
run.

Characteristics: Mounting and installation study References: Dimensions:


pages 11157/2 and 11157/3 guide: pages 11156/8 to 11156/11 pages 11158/3 to 11159/3 pages 11160/2 and 11160/3

11156_Ver1.00-EN.fm/2 Schneider Electric


Description Lighting distribution 0

Canalis KDP 20 A

Fixing devices

To fix KDP in accordance with recommended installation methods :

# Fixing to the edge of pre-slotted sheet metal cable racks : KDP-Z10.

1 Fixing to edge of sheet metal


For fixing the ribbon cable and the feed unit.

# Fixing to the edge of welded lattice cable racks : KDP-Z14.

1 Fixing to the wire cable rack


For fixing the ribbon cable and feed unit to wire
diameters between 5 and 8 mm.

# Fixing to metal structural work.

1 Fixing to metal structural work


For fixing the ribbon cable to I beams of the following
thicknesses :
- KDP-Z10 : 0 to 8 mm
- KDP-Z11 : 8 to 12 mm
- KDP-Z12 : 12 to 16 mm
H

- KDP-Z13 : 16 to 20 mm
e

1 Pour H ≥ 120 mm, the KDP may be fixed on top of


the I beam wing.

# Fixing to concrete slabs or wooden structures

1 Fixing clip for concrete or wood


- KDP-Z20 : for fixing the ribbon cable.

2 Concrete fixing
- KDP-Z21 : drill Ø = 8 mm.

1 2

Stripping tool

Enables sheath removal and wire stripping of KDP 3 or 5-conductor ribbon cables..

Characteristics: Mounting and installation study References: Dimensions:


pages 11157/2 and 11157/3 guide: pages 11156/8 to 11156/11 pages 11158/3 to 11159/3 pages 11160/2 and 11160/3

Schneider Electric 11156_Ver1.00-EN.fm/3


Description Lighting distribution 0

Canalis KDP 20 A

Tap-off units - General

For instant connection of lighting devices to the Canalis


KDP run.
# They can be connected when powered up and under
load.
# The live conductor contacts are of the clip type.
# The PE connection is established before the phase
or neutral connection.
# Phase selection system by means of clip-in contact
studs to allow balancing on a 3-phase supply.
# Selection visible through a transparent window.
# A coloured locking device holds them on the tap-off
!

contact stud.
2 1

# All insulating and plastic materials used have


increased fire resistance : resistance to incandescent
wire test conforming to IEC 695-2-1:
- 850°C for parts in contact,
- 650°C for other parts.

2-pole 10 A tap-off units KBC-10//// (with phase selection)

# The two contact studs are mobile and allow both L + N + PE and 2L + PE polarity.
# Supplied complete with cable gland.
10 A tap-off unit KBC-10CB20, 2-pole + PE, to be wired
.
To be wired for connection of luminaires by cable of a
specific type, c.s.a. or length.
Fast connection for 3 cables, 0.75 to 1.5 mm2.

10 A tap-off unit KBC-10CC211, 2-pole + PE, pre-wired


.
Pre-cabled with H05VVF 3 X 1.5 mm2 cable, 1m long,
with sheath pre-stripped at the luminaire end.

16 A tap-off unit with terminal connections KBC-16//// (with phase selection)

For connection of luminaires by cable of a specific type, c.s.a. or length.


# 2-pole : L + N + PE (1 mobile contact stud, fixed neutral) or 2L + PE (2 mobile contact studs).
# Installation is facilitated by side guides.
# Supplied complete with end grommet
# Terminal connections for 3 cables, 0.75 to 2.5 mm2
Tap-off units with terminal connections KBC-16CB //, direct (without protection)
.
For direct connection (without protection) of luminaires
by specific cable.

Fused tap-off units KBC-16CF//

For individual protection of each luminaire and


selectivity on a fault.
# Sub-base for fuse on the phase
(1 or 2 sub-bases, depending on the model).
# For NF 8.5 X 31.5 cylindrical fuse, 16 A gG max. (not
included), breaking capacity 20 kA.

Characteristics: Mounting and installation study References: Dimensions:


pages 11157/2 and 11157/3 guide: pages 11156/8 to 11156/11 pages 11158/3 to 11159/3 pages 11160/2 and 11160/3

11156_Ver1.00-EN.fm/4 Schneider Electric


Description Lighting distribution 0

Canalis KDP 20 A

Tap-off units KBC-16CB/CF//6 (L + N + PE preselected)

For tap-off and individual protection of luminaires


assigned to 2 independent circuits in a KDP 4-conductor
run.

# Identical design to the tap-off units on the page


!

3
2 1
opposite, but polarity is pre-selected at the factory.

Other accessories

1 Interlocking devices
for all 10 and 16 A tap-off units

A set of 3 different coloured devices allows


mechanical interlocking of the tap-off units between
2 or 3 networks of different types (application,
voltage, frequency, etc...).
2
# The unit consists of a handle and interlocking device
at each end. It can equip an outlet and its corresponding
1 tap-off unit

! # Self-adhesive legends can be stuck onto the tap-off


2 1
3
units and trunking to allow identification from a
distance.

2 Tap-off outlet blanking plate

A spare part designed to re-establish IP 54 degree


of protection to the tap-off outlet after permanent
removal of the tap-off unit (if the original blanking
plate has been lost

Characteristics: Mounting and installation study References: Dimensions:


pages 11157/2 and 11157/3 guide: pages 11156/8 to 11156/11 pages 11158/3 to 11159/3 pages 11160/2 and 11160/3

Schneider Electric 11156_Ver1.00-EN.fm/5


Description Lighting distribution 0

Canalis KDP 20 A

Prefabricated leads

To supply several luminaires from the same KBC tap-off unit, for distribution in false ceilings.

KBZ-31FM020 : 2 m
KBZ-31FM030 : 3 m
KBZ-31FM040 : 4 m
KBZ-31FM050 : 5 m
KBZ-31FM070 : 7 m
KBZ-31FM090 : 9 m

KBZ-31MC010 : 1 m KBZ-31FC010 : 1 m
KBZ-31FC030 : 3 m
KBZ-31FC050 : 5 m

2 3

KBZ-32PMR2 KBZ-32PFR2 KBZ-32BA12 KBZ-32BA15 KBZ-30VP01

4 5 6 7 8

1 KBZ31-FM///: male-female extension cable.


Cable type H05VVF 3 X 1.5 mm2, available in 2, 3, 4, 5, 7 and 9 metre lengths.
2 KBZ31-MC/// : for connection of luminaires. Connection cable with one male end and one end stripped for connection to a luminaire which
is not pre-equipped.
Cable type H05VVF 3 X 1.5 mm2, available in 1 metre length.
3 KBZ31-FC///: for connection to a KBC unwired tap-off unit. Connecting cable with one female end and one stripped end.
Cable type H05VVF 3 X 1.5 mm2, available in 1, 3 and 5 metre lengths.
4 KBZ32-PMR2 : Male connector. Spring connection for 2 rigid cables 3 x 1.5 to 2.5 mm2 or 2 stranded cables 3 x 1.5 to 2.5 mm2 fitted with
cable ends.
5 KBZ32-PFR2 : female connector. Spring connection for 2 rigid cables 3 x 1.5 to 2.5 mm2 or 2 stranded cables 3 x 1.5 to 2.5 mm2 fitted with
cable ends.
6 KBZ32-BA12 T connector. One male entry and two female outlets for connection of a pre-wired luminaire.
7 KBZ32-BA15 : splitter block. One male entry, five female outlets.
8 KBZ30-VP01 : lock for extension leads. Can withstand pulling forces greater than 20 N on the leads.

Characteristics: Mounting and installation study References: Dimensions:


pages 11157/2 and 11157/3 guide: pages 11156/8 to 11156/11 pages 11158/3 to 11159/3 pages 11160/2 and 11160/3

11156_Ver1.00-EN.fm/6 Schneider Electric


Description Lighting distribution 0

Canalis KDP 20 A

Option X : halogen-free version

Insulating materials and electrical cable and conductor sheaths which contain halogens
(chlorine, bromide...) give off opaque, toxic and corrosive fumes on combustion, in the
event of a fire.
These fumes can cause panic, hamper rescue operations and cause poisoning and
serious damage to electronic and computer equipment.
The halogen-free version of KDP eliminates these risks.

Applications

“Halogen-free” KDP is for customers and drawing offices who wish to specify this
characteristic for increased protection of personnel and objects :

- In buildings used by the public and tall buildings.


- In industrial buildings with large amounts of electronic and/or computer equipment.

Characteristics and certifications

Halogen-free KDP is certified as follows :

- non-propagation of flames or fire conforming to 60 332-1 and IEC 60 332-3.


- opacity of fumes conforming to 61 034-1 and IEC 61 034-2.
- toxicity and corrosiveness of fumes conforming to IEC 60 754-1 and IEC 60 754-2.

Special equipment

Run components
All 2 and 4-pole ranges, with tap-offs at 1.5 or 3 metre intervals, in 24 or 192 metre
lengths, are available in “halogen-free” version.

Accessories
All insulating materials and plastic parts used for accessories (feed unit, fixings,
etc...) have no components which contain halogens in their standard version.

Tap-offs
Tap-offs must be made by means of terminal connectors (with or without fuses) fitted,
by the system builder, with an LSOH cable to be connected to tap-off unit KBC-
10CB20 or KBC-16////.
Pre-wired tap-off units KBC-10CC211 cannot be used.

Prefabricated leads
With splitter blocks KBZ-32BA12/15, leads based on an LSOH cable and spring
connectors KBZ-32PFR2 and KBZ-32PMR2, will be made up by the system builder.

Characteristics: Mounting and installation study References: Dimensions:


pages 11157/2 and 11157/3 guide: pages 11156/8 to 11156/11 pages 11158/3 to 11159/3 pages 11160/2 and 11160/3

Schneider Electric 11156_Ver1.00-EN.fm/7


Mounting Lighting distribution 0

Canalis KDP 20 A

Mounting instructions describing the various assembly phases, are contained in the packs.
However, the main operations, outlined below, show how simple and fast it is to install KDP trunking.

Assembly of the uncoiler kit (2 x 4 parts)

Clic !
2

Assembly of the run component and feed unit

2
5
1
4
3

6 7
8

45
8 50

10
9

11

Characteristics: Description: References: Dimensions:


pages 11157/2 and 11157/3 pages 11156/2 to 11156/7 pages 11158/3 to 11159/3 pages 11160/2 and 11160/3

11156_Ver1.00-EN.fm/8 Schneider Electric


Mounting Lighting distribution 0

Canalis KDP 20 A

Installation of the KDP run on a welded lattice cable rack

KDP-Z14

mm
700
mm
200

mm
700

mm
200

Installation of the KDP run on a cable rack

KDP-Z10

mm
700

mm
200

mm
700

mm
200

Characteristics: Description: References: Dimensions:


pages 11157/2 and 11157/3 pages 11156/2 to 11156/7 pages 11158/3 to 11159/3 pages 11160/2 and 11160/3

Schneider Electric 11156_Ver1.00-EN.fm/9


Mounting Lighting distribution 0

Canalis KDP 20 A

Installation of a KDP run on metal structural work

mm
700
mm
200

mm
700

mm
200

Installation of a KDP run on concrete slabs or a wooden structure

KDP-Z21

KDP-Z20

mm
700

mm
200

mm
700

mm
200

Installation methods which differ from those recommended in the mounting instructions must conform to current wiring regulations.
Please refer to wiring regulations relating to cables with PER insulation and PVC sheathing, average mechanical environment AG2.

Installation of the end cover

m
25 m
20...

Characteristics: Description: References: Dimensions:


pages 11157/2 and 11157/3 pages 11156/2 to 11156/7 pages 11158/3 to 11159/3 pages 11160/2 and 11160/3

11156_Ver1.00-EN.fm/10 Schneider Electric


Mounting Lighting distribution 0

Canalis KDP 20 A

Assembly of prefabricated lead for supply to luminaires by bridge connection

KBC-10CB20

KBZ-32BA12
(1)

KBZ-31FC0 0 (2)

KBZ-31FM0 0

KBZ-30VP01
KBZ-31FM 0 (1) (1) For luminaires fitted with lead GST1813.
KBZ-31MC010 (2) (2) For luminaires not equipped with lead, with terminal block.

Assembly of prefabricated lead for supply to luminaires by star connection

KBC-10CB20

KBZ-31FM010

KBZ-32BA15 (1)

(1) Splitter block for one male entry (tap-off unit)


KBZ-31FC0 0 and five female outlets (luminaires).

Characteristics: Description: References: Dimensions:


pages 11157/2 and 11157/3 pages 11156/2 to 11156/7 pages 11158/3 to 11159/3 pages 11160/2 and 11160/3

Schneider Electric 11156_Ver1.00-EN.fm/11