COLUMN STAAD CALCULATIONS

COLUMN 1:

ACI 318-11 COLUMN NO. 16 DESIGN RESULTS

===============================================

FY - 413.7 FC - 27.6 MPA, SQRE SIZE - 650.0 X 650.0 MMS, TIED

AREA OF STEEL REQUIRED = 5129.1 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

----------------------------------------------------------

28 - 16 MM 1.332 1002 STA 0.650

(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

TIE BAR NUMBER 12 SPACING 192.00 MM

COLUMN 2:

ACI 318-11 COLUMN NO. 17 DESIGN RESULTS

===============================================

FY - 413.7 FC - 27.6 MPA, SQRE SIZE - 650.0 X 650.0 MMS, TIED

AREA OF STEEL REQUIRED = 6447.4 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

----------------------------------------------------------

36 - 16 MM 1.713 1001 STA 0.650

(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

TIE BAR NUMBER 12 SPACING 256.00 MM


COLUMN 3:

ACI 318-11 COLUMN NO. 22 DESIGN RESULTS

===============================================

FY - 413.7 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED

AREA OF STEEL REQUIRED = 2840.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

----------------------------------------------------------

28 - 12 MM 1.267 18 END 0.650

(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

TIE BAR NUMBER 12 SPACING 192.00 MM

COLUMN 4:

ACI 318-11 COLUMN NO. 55 DESIGN RESULTS

===============================================

FY - 413.7 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED

AREA OF STEEL REQUIRED = 4595.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

----------------------------------------------------------

24 - 16 MM 1.930 1003 END 0.650

(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

TIE BAR NUMBER 12 SPACING 192.00 MM


COLUMN 5:

ACI 318-11 COLUMN NO. 56 DESIGN RESULTS

===============================================

FY - 413.7 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED

AREA OF STEEL REQUIRED = 4985.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

----------------------------------------------------------

4 - 40 MM 2.011 1003 END 0.650

(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

TIE BAR NUMBER 12 SPACING 256.00 MM

COLUMN 6:

ACI 318-11 COLUMN NO. 28 DESIGN RESULTS

===============================================

FY - 413.7 FC - 27.6 MPA, SQRE SIZE - 450.0 X 450.0 MMS, TIED

AREA OF STEEL REQUIRED = 3406.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

----------------------------------------------------------

12 - 20 MM 1.862 18 END 0.650

(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

TIE BAR NUMBER 12 SPACING 192.00 MM


COLUMN 7:

ACI 318-11 COLUMN NO. 61 DESIGN RESULTS

===============================================

FY - 413.7 FC - 27.6 MPA, SQRE SIZE - 450.0 X 450.0 MMS, TIED

AREA OF STEEL REQUIRED = 3879.9 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

----------------------------------------------------------

8 - 25 MM 1.939 19 END 0.650

(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

TIE BAR NUMBER 12 SPACING 192.00 MM

COLUMN 8

ACI 318-11 COLUMN NO. 29 DESIGN RESULTS

===============================================

FY - 413.7 FC - 27.6 MPA, SQRE SIZE - 450.0 X 450.0 MMS, TIED

AREA OF STEEL REQUIRED = 3090.1 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

----------------------------------------------------------

28 - 12 MM 1.564 1001 END 0.650

(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

TIE BAR NUMBER 12 SPACING 192.00 MM


COLUMN 9:

ACI 318-11 COLUMN NO. 62 DESIGN RESULTS

===============================================

STAAD SPACE -- PAGE NO. 1677

FY - 413.7 FC - 27.6 MPA, SQRE SIZE - 450.0 X 450.0 MMS, TIED

AREA OF STEEL REQUIRED = 3564.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

----------------------------------------------------------

12 - 20 MM 1.862 1001 END 0.650

(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

TIE BAR NUMBER 12 SPACING 320.00 MM