Sie sind auf Seite 1von 8

March 2018 Series 1000 and 2000 Transmitters

Software 2

Code Software options 2 for Model 2500


Z No software options 2
C Smart Meter Verification

Not available with Mounting Option B; Smart Meter Verification is not available with all sensors.
W Weights and measures custody transfer (requires user-provided external sealing for approval)
D Weights and measures custody transfer & Smart Meter Verification (requires user-provided external sealing)

Not available with Mounting Option B; Smart Meter Verification is not available with all sensors.
X ETO software option 2

Requires factory code X

Factory

Code Factory options for Model 2500


Z Standard product
X ETO product

Add on Options

Code Add on options for Model 2500


Country specific approval (select one from the following if approval code G is selected):
R4 EAC Safe Area Only with IS Sensor Outputs - Hazardous Area Approval
B4 INMETRO Safe Area Only with IS Sensor Outputs - Hazardous Area Approval

Model 2700
Base model

Model Product description


2700 Micro Motion Coriolis MVD Model 2700 multivariable flow and density transmitter

www.emerson.com 41
Series 1000 and 2000 Transmitters March 2018

Mounting

Code Mounting options for Model 2700


R 4-wire remote mount transmitter (polyurethane-painted aluminum housing) includes 10 ft. [3m] 4 wire shielded
PVC cable
I Integral mount transmitter (polyurethane-painted aluminum housing)
E 4-wire remote mount transmitter with 9-wire remote enhanced core processor; includes 10 ft. (3 m) each of 4-wire
shielded PVC cable and 9-wire shielded FEP cable;

Mounting code B, E not available with conduit connection code C or D; Available with approval options M, C, A, F, Z,
P or I only; Not available with approval option codes S or T or with Conduit Connections L or M.
B 4-wire remote mount transmitter with 9-wire remote core processor (polyurethane-painted aluminum housing)
includes 10 ft. [3m] each 9 wire shielded FEP and 4 wire shielded PVC cable

Mounting code B, E not available with conduit connection code C or D


C 9-wire remote transmitter with integral core processor (polyurethane-painted aluminum housing) includes 10 ft.
[3m] CFEPS cable

Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G with country-specific appro-
val codes R1 and B1;
M 4-wire remote mount transmitter with stainless steel housing; includes 10 ft. (3 m) 4-wire shielded PVC cable;

Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G, with country-specific appro-
val R1or B1; Mounting codes M and P are not available with Output codes 2 and 3 because the SS housing is not
Zone 1 increased safety (Ex e) approved.
P 9-wire remote mount transmitter with stainless steel housing and integral core processor; includes 10 ft. (3m)
CFEPS cable

Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G, with country-specific appro-
val R1or B1; Mounting codes M and P are not available with Output codes 2 and 3 because the SS housing is not
Zone 1 increased safety (Ex e) approved.
H 4-wire remote mount transmitter (polyurethane-painted aluminum housing) for connecting to CDM/FDM/FVM
meters [power and communications] includes 10ft (3m) 4 wire shielded PVC cable

Not available with approval codes J, T or S

Power

Code Power options for Model 2700


1 18 to 100 VDC or 85 to 265 VAC; self switching

Display

Code Display options for Model 2700


1 Dual line display for CSA, UL, and IIB + H2 ATEX, IECEx and NEPSI ratings;

Not available with mounting codes M, P; or H


2 Backlit dual line display for CSA, UL, and IIB + H2 ATEX, IECEx and NEPSI ratings
3 No display

Not available with approval codes J, T, or S


5 Backlit dual line display for IIC ATEX, IECEx, and NEPSI rating

Only available with approval codes Z, F, P, K, I, E, L, or 3

42 www.emerson.com
March 2018 Series 1000 and 2000 Transmitters

Code Display options for Model 2700


7 Backlit dual line display for process variables and totalizer reset, non-glass lens
Only available with approval code M; not available with mounting codes M, H, or P
8 Display optimized for Chinese-language support; China only

Only available with mounting code R, I, C, or B, output code A, conduit connection code B, C, D, E, F or G, and
approval code M, Z, F, P, K, I, or G code with country specific approval R1, R2, B1, B2

Output

Code Output options for Model 2700


A Analog outputs: one mA; one frequency; RS-485

Not available with mounting code H


B One mA; two configurable IO channels - default configuration of 2 mA, 1 FO

Not available with mounting code H


C One mA; two configurable IO channels - custom configuration

Not available with mounting code H


D Intrinsically safe analog outputs: two mA, one frequency;

Not available with mounting code H; Output code D and E are not available with approval codes T, S, and J.
E Foundation fieldbus intrinsically safe H1 with standard function blocks (4 x AI, 1 x AO, 1 x integrator, 1 x DI, 1 x DO)

Output code D and E are not available with approval codes T, S, and J; Output code E is not available with approval
code U, 2, L, 3 or G with country specific approval codes R3 or B3
G PROFIBUS-PA; not available with approval codes U, 2, L and 3

Output code G not available with approval codes U, 2, L , 3 or G with country-specific approval option R3, B3; not
available with mounting code H:
N Foundation Fieldbus H1 with standard function blocks (4 x AI, 1 x AO, 1 x integrator, 1 x DI, 1 x DO);

Output code N is not available with approval codes U, C, A, E, 2, L, 3 or G with country-specific approval R3, B3
2 One mA; one frequency; RS485; Wireless HART ready; order 775 with 1/2” NPT mounting option

Not available with mounting code H; output codes 2 and 3 are only available with approval codes M, 2, L, 3, G with
country-specific approval R3, B3.
3 One mA; two configurable IO channels - custom configuration; Wireless HART ready; order 775 with 1/2” NPT
mounting option

Not available with approvals J, T or S; not available with mounting code H; output codes 2 and 3 are only available
with approval codes M, 2, L, 3, G with country-specific approval R3, B3.
4 Intrinsically safe outputs; two mA; one frequency; Wireless HART ready; order 775 with 1/2” NPT mounting option

Not available with mounting code H; output code 4 is only available with approval codes E, Z, A, or G with country-
specific approval R1, B1 when using stopping box

www.emerson.com 43
Series 1000 and 2000 Transmitters March 2018

Conduit connection

Code Conduit connection options for Model 2700


Available with mounting codes: R I B E C M P H
B 1/2-inch NPT – no gland; ● ● ● ● ● ● ● ●

Not available with approval code T, S, or J


Only available with mounting code R, I, B, E, C, M, or P:
C 1/2-inch NPT with brass nickel cable gland (not approved ● ● ●
in Class 1 Division 1 installations)

Not available with approval code T, S, or J; mounting code


B, E not available with Conduit Connection C or D; not
available with mounting code M, or P
D 1/2-inch NPT with stainless steel cable gland (not ap- ● ● ● ● ●
proved in Class 1 Division 1 installations)

Not available with approval codes J, T, or S; mounting co-


des B or E not available with Conduit Connection codes C
or D
E M20 – no gland ● ● ● ● ● ● ●

Not available with approvals T or S


F M20 with brass nickel cable gland (not approved in Class 1 ● ● ● ● ●
Division 1 installations)

Not available with mounting code M or P


G M20 with stainless steel cable gland (not approved in Class ● ● ● ● ● ● ●
1 Division 1 installations)
K JIS B0202 1/2G – no gland ● ● ● ● ●

Only available with approval code M; not available with


mounting code M or P
L Japan - brass nickel cable gland ● ● ● ● ●

Only available with approval codes M, T, or S; not available


with mounting code M or P
M Japan - stainless cable gland ● ● ● ● ●

Only available with approval codes M, T, or S; not available


with mounting code M or P

Approval

Code Approval options for Model 2700


M Micro Motion Standard (no approval, with CE/EAC mark)
U UL

Approval code U is available with conduit codes B or E only.


C CSA (Canada only)
A CSA C-US (US and Canada)
Z ATEX - Equipment Category 2 (Zone 1 - Increased safety terminal compartment)
F ATEX - Equipment Category 2 (Zone 1 - Flameproof terminal compartment)

44 www.emerson.com
March 2018 Series 1000 and 2000 Transmitters

Code Approval options for Model 2700


P NEPSI – Equipment Category 2 (Zone 1– Flameproof terminal compartment);
Available with Chinese (M) language option only
K NEPSI – Equipment Category 2 (Zone 1 – Increased safety terminal compartment)

Available with Chinese (M) language option only


I IECEx Equipment Category 2 (Zone 1 – Flameproof terminal compartment)
T TIIS - IIC sensor (not available for quotes outside of Japan)

Available for quote only


S TIIS - IIB sensor (not available for quotes outside of Japan)

Available for quote only


J Hardware ready for TIIS approval (EPM Japan only)

Approval code J is only available with Conduit Connections Option E; Available for order only
E IECEx (Zone 1 - Increased safety terminal compartment)

Only available with output code 4


2 CSA Class 1 Div. 2 (US and Canada)

Sensor connections will be intrinsically Safe without additional barrier


L ATEX - Equipment Category 3 (Zone 2)

Sensor connections will be intrinsically Safe without additional barrier; Approval code L is only available with output
options 2 and 3.
3 IECEx (Zone 2)

Sensor connections will be intrinsically Safe without additional barrier


G Country Specific Approval - Requires a selection from the Approvals section of the Add on Options

Language

Code Language options for Model 2700


A Danish CE requirements document; English installation and configuration manuals
D Dutch CE requirements document; English installation and configuration manuals
E English installation manual; English configuration manual
F French installation manual; French configuration manual
G German installation manual; German configuration manual
H Finnish CE requirements document; English installation and configuration manuals
I Italian installation manual; English configuration manual
J Japanese installation manual; Japanese configuration manual
M Chinese installation manual; Chinese configuration manual
N Norwegian CE requirements document; English installation and configuration manuals
O Polish installation manual; English configuration manual
P Portuguese installation manual; English configuration manual
S Spanish installation manual; Spanish configuration manual
W Swedish CE requirements document; English installation and configuration manuals

www.emerson.com 45
Series 1000 and 2000 Transmitters March 2018

Code Language options for Model 2700


C Czech CE requirements document; English installation and configuration manuals
B Hungarian CE requirements document; English installation and configuration manuals
K Slovak CE requirements document; English installation and configuration manuals
T Estonian CE requirements document; English installation and configuration manuals
U Greek CE requirements document; English installation and configuration manuals
L Latvian CE requirements document; English installation and configuration manuals
V Lithuanian CE requirements document; English installation and configuration manuals
Y Slovenian CE requirements document; English installation and configuration manuals

Software 1

Code Software options 1 — only available with mounting codes R, I, B, E, C, M, and P


Z Flow and density variables (standard)
G Concentration measurement
A Petroleum measurement
J Production Volume Reconciliation

Approval code J is only available with conduit connections option E.


K Transient Mist Remediation

Approval code J is only available with conduit connections option E.


L Transient Bubble Remediation

Approval code J is only available with conduit connections option E.


M Fuel consumption

Approval code J is only available with conduit connections option E.


Q Transient Bubble Remediation and petroleum measurement

Approval code J is only available with conduit connections option E.


R Piece-wise linearization for gas

Approval code J is only available with conduit connections option E.


X ETO software option 1

Requires factory code X

46 www.emerson.com
March 2018 Series 1000 and 2000 Transmitters

Software options 1 — only available with mounting code H

Code (1)

B CDM density meter connection - IIC ATEX & IECEx rating

Not available with display code 2


C FDM density meter connection - IIC ATEX & IECEx rating

Not available with display code 2


D FVM viscosity meter connection - IIC ATEX & IECEx rating

Not available with display code 2


E CDM density meter connection - CSA C1D1 & C1D2 and Zone 2 or 3 ATEX, IECEx ratings

Not available with display code 5


F FDM density meter connection - CSA C1D1 & C1D2 and Zone 2 or 3 ATEX, IECEx ratings

Not available with display code 5


H FVM viscosity meter connection - CSA C1D1 & C1D2 and Zone 2 or 3 ATEX, IECEx ratings

Not available with display code 5


(1) All concentration measurement or petroleum measurement options are automatically programmed by the CDM / FDM.

Software 2

Code Software options 2 for Model 2700 — available with all mounting codes
Z No software options 2
W Weights & measures custody transfer

Only available with output codes A, B, C, 2 or 3; Not available with Software Options 1 codes C or D
X ETO software option 2; requires factory code X

Code Software options 2 for Model 2700 — available only with mounting codes R, I, B, E, C, or M and P
C Smart Meter Verification

Not available with Mounting Option I, B, C, or P; Smart Meter Verification is not available with all sensors.
D Weights & measures custody transfer and Smart Meter Verification

Not available with Mounting Option I, B, C, or P; Smart Meter Verification is not available with all sensors.
A Regulatory Control Suite: Standard function blocks plus 1 PID block

Available with output codes E and N only


F Regulatory Control Suite: Standard function blocks plus 1 PID block & Smart Meter Verification

Available with output codes E and N only; Available with sensor electronic interface codes 2 through 5 only; Not
available with mounting option I, B, E, C, or P
S Safety Certification of 4-20 mA output per IEC 61508

Available with Output codes A, B, C, and D only

www.emerson.com 47
Series 1000 and 2000 Transmitters March 2018

Code Software options 2 for Model 2700 — available only with mounting codes R, I, B, E, C, or M and P
V Safety Certification per IEC 61508 with Smart Meter Verification

Available with output codes E and N only; Available with sensor electronic interface codes 2 through 5 only; Not
available with mounting option I, B, E, C, or P; Not available with approval options S or T with conduit connections L
or M

Factory

Code Factory options for Model 2700


Z Standard product
X ETO product

Add on Options

Code Add on options for Model 2700 — Available only for output code 2, 3, or 4
PI Model 775 integrally mounted at the factory, wiring completed in the field

Not available with approvals J, T, or S; Add on option PI is not available with Output code 4 and approval code A.
CSA requires installation with a poured conduit seal or stopping box between the transmitter and the 775 Thum.
NI Model 775 not installed, installation and wiring completed in the field

Not available with approvals J, T, or S

Code Add on options for Model 2700 — for mounting code R, B, E, H, M, P, or C


PK 2-inch pipe mount U-bolt kit for electronics

Add on options for Model 2700 — Country‐specific approval (select one from the following if approval code G
Code is selected)
R1 EAC Zone 2 - Hazardous Area Approval - Increased safety terminal compartment (Exe)
R2 EAC Zone 1 - Hazardous Area Approval - Flameproof terminal compartment
R3 EAC Zone 2 - Hazardous Area Approval - Energy limited device (ExnA )

Sensor connections will be intrinsically safe without additional barrier


B1 INMETRO Zone 1 - Hazardous Area Approval - Increased safety terminal compartment N/C
B2 INMETRO Zone 1 - Hazardous Area Approval - Flameproof terminal compartment
B3 INMETRO Zone 2 - Hazardous Area Approval

Sensor connections will be intrinsically safe without additional barrier

48 www.emerson.com

Das könnte Ihnen auch gefallen