Beruflich Dokumente
Kultur Dokumente
Software 2
Not available with Mounting Option B; Smart Meter Verification is not available with all sensors.
W Weights and measures custody transfer (requires user-provided external sealing for approval)
D Weights and measures custody transfer & Smart Meter Verification (requires user-provided external sealing)
Not available with Mounting Option B; Smart Meter Verification is not available with all sensors.
X ETO software option 2
Factory
Add on Options
Model 2700
Base model
www.emerson.com 41
Series 1000 and 2000 Transmitters March 2018
Mounting
Mounting code B, E not available with conduit connection code C or D; Available with approval options M, C, A, F, Z,
P or I only; Not available with approval option codes S or T or with Conduit Connections L or M.
B 4-wire remote mount transmitter with 9-wire remote core processor (polyurethane-painted aluminum housing)
includes 10 ft. [3m] each 9 wire shielded FEP and 4 wire shielded PVC cable
Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G with country-specific appro-
val codes R1 and B1;
M 4-wire remote mount transmitter with stainless steel housing; includes 10 ft. (3 m) 4-wire shielded PVC cable;
Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G, with country-specific appro-
val R1or B1; Mounting codes M and P are not available with Output codes 2 and 3 because the SS housing is not
Zone 1 increased safety (Ex e) approved.
P 9-wire remote mount transmitter with stainless steel housing and integral core processor; includes 10 ft. (3m)
CFEPS cable
Mounting codes M and P are not available with approval codes U, Z, P, K, T, S, J, E or G, with country-specific appro-
val R1or B1; Mounting codes M and P are not available with Output codes 2 and 3 because the SS housing is not
Zone 1 increased safety (Ex e) approved.
H 4-wire remote mount transmitter (polyurethane-painted aluminum housing) for connecting to CDM/FDM/FVM
meters [power and communications] includes 10ft (3m) 4 wire shielded PVC cable
Power
Display
42 www.emerson.com
March 2018 Series 1000 and 2000 Transmitters
Only available with mounting code R, I, C, or B, output code A, conduit connection code B, C, D, E, F or G, and
approval code M, Z, F, P, K, I, or G code with country specific approval R1, R2, B1, B2
Output
Not available with mounting code H; Output code D and E are not available with approval codes T, S, and J.
E Foundation fieldbus intrinsically safe H1 with standard function blocks (4 x AI, 1 x AO, 1 x integrator, 1 x DI, 1 x DO)
Output code D and E are not available with approval codes T, S, and J; Output code E is not available with approval
code U, 2, L, 3 or G with country specific approval codes R3 or B3
G PROFIBUS-PA; not available with approval codes U, 2, L and 3
Output code G not available with approval codes U, 2, L , 3 or G with country-specific approval option R3, B3; not
available with mounting code H:
N Foundation Fieldbus H1 with standard function blocks (4 x AI, 1 x AO, 1 x integrator, 1 x DI, 1 x DO);
Output code N is not available with approval codes U, C, A, E, 2, L, 3 or G with country-specific approval R3, B3
2 One mA; one frequency; RS485; Wireless HART ready; order 775 with 1/2” NPT mounting option
Not available with mounting code H; output codes 2 and 3 are only available with approval codes M, 2, L, 3, G with
country-specific approval R3, B3.
3 One mA; two configurable IO channels - custom configuration; Wireless HART ready; order 775 with 1/2” NPT
mounting option
Not available with approvals J, T or S; not available with mounting code H; output codes 2 and 3 are only available
with approval codes M, 2, L, 3, G with country-specific approval R3, B3.
4 Intrinsically safe outputs; two mA; one frequency; Wireless HART ready; order 775 with 1/2” NPT mounting option
Not available with mounting code H; output code 4 is only available with approval codes E, Z, A, or G with country-
specific approval R1, B1 when using stopping box
www.emerson.com 43
Series 1000 and 2000 Transmitters March 2018
Conduit connection
Approval
44 www.emerson.com
March 2018 Series 1000 and 2000 Transmitters
Approval code J is only available with Conduit Connections Option E; Available for order only
E IECEx (Zone 1 - Increased safety terminal compartment)
Sensor connections will be intrinsically Safe without additional barrier; Approval code L is only available with output
options 2 and 3.
3 IECEx (Zone 2)
Language
www.emerson.com 45
Series 1000 and 2000 Transmitters March 2018
Software 1
46 www.emerson.com
March 2018 Series 1000 and 2000 Transmitters
Code (1)
Software 2
Code Software options 2 for Model 2700 — available with all mounting codes
Z No software options 2
W Weights & measures custody transfer
Only available with output codes A, B, C, 2 or 3; Not available with Software Options 1 codes C or D
X ETO software option 2; requires factory code X
Code Software options 2 for Model 2700 — available only with mounting codes R, I, B, E, C, or M and P
C Smart Meter Verification
Not available with Mounting Option I, B, C, or P; Smart Meter Verification is not available with all sensors.
D Weights & measures custody transfer and Smart Meter Verification
Not available with Mounting Option I, B, C, or P; Smart Meter Verification is not available with all sensors.
A Regulatory Control Suite: Standard function blocks plus 1 PID block
Available with output codes E and N only; Available with sensor electronic interface codes 2 through 5 only; Not
available with mounting option I, B, E, C, or P
S Safety Certification of 4-20 mA output per IEC 61508
www.emerson.com 47
Series 1000 and 2000 Transmitters March 2018
Code Software options 2 for Model 2700 — available only with mounting codes R, I, B, E, C, or M and P
V Safety Certification per IEC 61508 with Smart Meter Verification
Available with output codes E and N only; Available with sensor electronic interface codes 2 through 5 only; Not
available with mounting option I, B, E, C, or P; Not available with approval options S or T with conduit connections L
or M
Factory
Add on Options
Code Add on options for Model 2700 — Available only for output code 2, 3, or 4
PI Model 775 integrally mounted at the factory, wiring completed in the field
Not available with approvals J, T, or S; Add on option PI is not available with Output code 4 and approval code A.
CSA requires installation with a poured conduit seal or stopping box between the transmitter and the 775 Thum.
NI Model 775 not installed, installation and wiring completed in the field
Add on options for Model 2700 — Country‐specific approval (select one from the following if approval code G
Code is selected)
R1 EAC Zone 2 - Hazardous Area Approval - Increased safety terminal compartment (Exe)
R2 EAC Zone 1 - Hazardous Area Approval - Flameproof terminal compartment
R3 EAC Zone 2 - Hazardous Area Approval - Energy limited device (ExnA )
48 www.emerson.com