Sie sind auf Seite 1von 2

Signify Classified Internal

Signify Innovations India Limited


S Igflhi 0-47 Sector-57, Noida
U.P. -201301, India

Report No.: DQITTCI2OI9/09 Date: 08-Mar-2019

TYPE TEST CERTIFICATE

This is to certify the following product(s) (Type Name/i 2NC):


• RC37OB LED36S-6500 G5 L60W60 PSU OD /9195 158 13164
• RC37OB LED36S-4000 G5 L60W60 PSU OD / 9195 158 13165

Description:
Philips R0370B luminaire is a 2x2 full glow solution with diffuser, which provides
completely diffused light with no dark patches and shadows. It ensures energy savings as compared
to conventional recess lights.

Features and Benefits:


• Energy efficient with built-in driver unit
• 1P20
• Easy to install and maintain

Applications:
• Office lighting.
• General room lighting — reception, cabins, corridors & conference
rooms.

Installation:
• Recess mounting as per instruction manual.

The Luminaire has been tested as per Standard Specification IEC 60598-2-2 / IS: 10322(Part5ISec2),
the results of 1 (one) sample(s) each tested being shown in the enclosed sheet(s). The report has
established conformity of the product(s) to the requirements of the Standard/Specification.

‘ish Mukherjee
Director Technical
-

1 I 2 Page of DQJTTC/2019/09
Signify Classified - Internal
Signify Innovations India Limited
S ignia 0-47, Sector-57,
U.P. -201301, India

Report No.: DQITTCI2O 19109 Date: 08-Mar-20 19

TYPE TEST REPORT

Standard Referred: IEC 60598-2-2

Sample Tested: One

Test Results:

S. Clause
Test Requirements Result Obtained
No. No.

a) - Visual Examination - Satisfactory

Luminaire shall not


b) 2.13 Endurance test became unsafe after the Complied with the requirements
test
Thermal test (Normal Temperature in C at an Limiting temperature (°C)
operating condition) ambient of 45°C

Drivertc 80°C 65.5°C

Resistance to dust &


c) 2.14 lP2O Complied with the requirements
moisture

d) 2.15 Insulation Resistance test 2MQ > 200M0

Withstood satisfactorily 1 480Vrms for


No flashover or breakdown
e) 2.15 Electric Strength test 1mm between live parts & accessible
shall occur during the test
parts specified.
f) 2.16 Resistance to heat, fire & - Complied
tracking

g) - Photometry - Refer LM79 report

Debasi Mukherjee
Director Technical
-

2 I 2 Page of DOJTTC/2019/09

Das könnte Ihnen auch gefallen