LAMPIRAN III

SPESIFIKASI ALAT
1. CHILLER-01 (C-01)
Fungsi : menurunkan temperatur aliran keluaran yang berasal Reaktor-01
Jenis : Shell and Tube Heat Exchanger
Jumlah : 1 unit
Bahan : Carbon Steel SA-285 Grade C

Fluida Panas : Crude Nitro


Flow rate, W1 = 156.045,3356 kg/hr = 344.020,6677 lb/hr
T1 = 135 oC = 275 oF
T2 = 50 oC = 122 oF

Fluida Dingin : Amoniak


Flow rate, W2 = 16.227,0477 kg/hr= 35.774,4739 lb/hr
t1 = -33 oC = -27 oF
t2 = -33oC = -27 oF

Perhitungan design sesuai dengan literatur pada Kern Hal 102-123.


a. Panas yang dipertukarkan (Q)
Q = 22.208.499,7256 kJ/jam = 21.049.504,7504 Btu/hr
b. Menentukan Mean Temperature Difference (∆t m)

205
206

(T1  t 2 )  (T2  t1 )
LMTD  (Coulson, p-529)
ln (T1  t 2 ) /(T2  t1 ) 
LMTD = 216,9833 oF
Tc = ½ (275 + 122) 0F = 198,5 oF
tc = ½ (-27 + -27) 0F = -27 oF
Ft = 1 (Fig.12.19,Coulson)
∆t= Ft x LMTD = 0,85 x 216,9833 oF = 216,9833 oF

c. Menentukan nilai Overall Coefficient (U)


Dari Donald Q. Kern (1965 : 840) Tabel 8 Approximate Overall Design
Coefficient, didapatkan U = 50 – 125
Asumsi U = 70 Btu/hr.ft2.F

d. Menentukan nilai Heat transfer area (A)


Q
A
U  t m

21.049.504,7504 Btu/hr
A
(70 Btu / hr. ft 2 .o F )  (216,9833 o F )
A = 1385,8541 ft2
Karena surface area A > 200 ft2, maka direncanakan menggunakan Shell and
Tube Heat Exchanger dengan spesifikasi : (Tabel 10,
Kern)
 Panjang tube = 18 ft
 Outside Diameter = 1 inchi
 BWG = 18
 Pass =2
 PT, pitch = 1 1⁄4 in triangular pitch
 a” = 0,2618 ft

e. Menghitung Jumlah tube, Nt


207

A
Nt =
L.a"

1385,8541 ft 2
=
18 ft x 0,2618 ft
= 294,0867
Ambil Nt pada tabel 9 Kern (hal. 842) yang mendekati, sesuai dengan ukuran
tube yang telah dipilih, Nt = 334

f. Koreksi design overall coefficient of heat transfer, UD


A = Nt.L.a”
= 334 x 18 ft x 0,2618 ft
= 1573,9416 ft2
Q
UD=
A.T
21.049.504,7504 Btu/jam
=
1573,9416 ft 2 x 216,9833 o F
= 61,6349 Btu/jam ft2 oF

Karena UD mendekati asumsi, maka dari tabel 9 Kern diperoleh data sebagai
berikut :
• Shell Side :
ID = 31 in
PT =1 1⁄4 in triangular pitch
C” = (PT – OD tube)
= 1,25 in – 1 in = 0,25 in
Baffle space = 1⁄2 x 31 in = 15,5 in
Pass =1
• Tube Side :
OD = 1 in
ID = 0,902 in
BWG = 18
208

Panjang = 18 ft
PT, pitch = 1 1⁄4in triangular pitch
Pass =2
Tube Side : Fluida panas, asam sulfat recycle
1.) Menghitung flow area fluida panas yang mengalir pada tube side, at
ao = 0,639 in2 (flow area per tube)
N t .a o
at = (Pers. 7.48,
144 in 2 / ft 2 .n
Kern)
42,8876 x (0,639 in 2 )
=
(144 in 2 / ft 2 )( 2)
= 0,0951 ft2

2.) Menghitung laju alir massa fluida panas pada tube side, Gt
W
Gt = (Pers. 7.1,
at
Kern)
35.774,4739 lb/jam
=
0,0951 ft 2
= 376.177,4332 lb/ft2 jam

3.) Menghitung bilangan reynold fluida pada tube side, Ret


Pada temperatur rata-rata, tc = 103 oF diperoleh data sebagai berikut :
µ = 0,1961 cP = 0,4746 lb/ft hr
De = ID = 0,902 in = 0,0752 ft
Cp = 1,100 Btu/lb oF
k = 0,3465 Btu/hr ft oF
G t x De
Ret =

376.177,4332 lb/hr ft 2 x 0,0752 ft


=
0,4746 lb/ft hr
209

= 59.505,0210
Dengan menghitung reynold number maka diperoleh :
Heat transfer factor, JH = 180 (Fig. 24, Kern)

4.) Menghitung koefisien perpindahan panas inside fluida, hio


0 ,14
 k    Cp    
1/3

hi = J H . .  . (Pers. 6.15a,


 D   k    w 
Kern)
0 ,14
  
  1
 w 
1/3
 0,3465 Btu/hr.ft. o F   (0,4746lb / hr. ft ) x(1,100 Btu / lb.o F ) 
= 180 .  .1
 0,0752ft  0,3465 Btu/hr.ft. o F 
hi = 950,8081 Btu/ft2 jam oF

Nilai hi yang diperoleh digunakan untuk menghitung heat transfer coefficient


outside diameter, hio
hio = hi x (ID/OD)
= 950,8081 Btu/ ft2 hr oF x (0,902/1)
= 857,6289 Btu/ft2 hr oF

Shell Side :Fluida dingin, saturated amoniak


1.) Menghitung flow area fluida dingin yang mengalir pada shell side, as
ID x C" x B
as = (Pers. 7.1, Kern)
144 x PT

31x 0,25x 15,5


=
144 x 1,25
= 0,6674 ft2

2.) Menghitung laju alir massa fluida dingin pada shell side, Gs
210

W
Gs =
as

35.774,4739 lb/jam
=
0,6674 ft 2
= 53.602,7478 lb/jam ft2

3.) Menghitung bilangan reynold fluida pada shell side, Res


Pada temperatur rata-rata, Tc = 198,5 oF diperoleh data sebagai berikut :
µ = 0,700 cP = 1,6940 lb/ft jam
De = 0,72 in = 0,06 ft
Cp = 1,100 Btu/lb oF
k = 0,372 Btu/hr ft oF
G s x De
Res=

53.602,7478 lb/jam ft 2 x 0,06 ft


=
1,6940 lb/ft jam
= 1898,5624

Dengan menghitung reynold number maka diperoleh :


Heat transfer factor, JH = 28 (Fig. 28, Kern)

4.) Menghitung koefisien perpindahan panas, ho


0 ,14
 k    c    
1/3

ho = J H . .  . , (Pers. 6.15b,


 D   k    w 
Kern)
0 ,14
  
  1
 w 
1/ 3
 0,372 Btu/lb. o F   (1,6940lb / hr. ft ) x (1,1) 
= 28. . o
 .1
 0 ,06 ft   ( 0,372 Btu / lb . F ) 
ho = 297,0296 Btu/ft2 jam oF
211

5.) Menghitung clean overall coefficient, U


h io x h o
Uc = (Pers. 6.7, Kern)
h io  h o

(857,6289 Btu/ft 2 hr o F).(297,0296 Btu/ft 2 hr o F)


=
(857,6289 Btu/ft 2 hr o F)  (297,0296 Btu/ft 2 hr o F)
= 220,6203 Btu/ft2 jam oF

6.) Menghitung dirt factor, Rd


UC  UD
Rd =
UC x U D

(220,6203 Btu/ft 2 hr o F) - (61,6349 Btu/ft 2 hr o F)


=
(220,6203 Btu/ft 2 hr o F) x (61,6349 Btu/ft 2 hr o F)
= 0,0117 jam ft2 oF/Btu

PRESSURE DROP
TUBE SIDE : Fluida panas
1.) Friction factor, f
Ret = 59.505,0210
f = 0,00035 (Fig. 26, Kern)
s = 1,84

2.) Pressure drop


2
f x Gt x L x n
ΔPt = (Pers. 7.47, Kern)
5,22x10 10 x D e x s x  t

(0,00035) x ( 376.177,4332 lb/ft hr) 2 x (18) x (2)


=
5,22x1010 x (0,0752) x (0,826) x 1
= 0,5499 psi

3.) Persamaan velocity head :


Gt = 376.177,4332 lb/ft2 jam
212

Dari fig.27 Kern (hal. 837) dengan Gt = 376.177,4332 lb/ft2 jam, maka
V2/2g = 0,018 lb/ft2 jam
Perubahan arah adanya penambahan pressure drop (ΔPt) disebut return loss
dan dihitung untuk 4 velocity head per pass, maka return loss untuk beberapa
fluida menjadi :

4.n v 2 4(2)
ΔPr = x  x 0,018  0,0782 psi
s 2g 1,84
Total tube side pressure drop (ΔPT) menjadi :
ΔPT = ΔPt + ΔPr
= (0,5499 +0,0782) psi
= 0,6281 psi

SHELL SIDE : Fluida dingin


Pressure drop yang terjadi pada shell sebanding dengan jumlah fluida yang
melewati sekat (bundle) di antara baffle.
1.) Friction factor, f
Res= 1898,5624
f = 0,0013 (Fig. 29, Kern)
s = 0,826

2.) Jumlah lintasan


Jumlah sekat (bundle) yang dilalui (N+1), dimana N yaitu jumlah baffle dan
L yaitu panjang tube
12.L 12 x 216 in
Nt + 1 =   167,23
B 15,5 int
ID 31 ft
Ds =   2,5833 ft
12 12

3.) Persamaan isotermal untuk pressure drop fluida yang dipanaskan atau
didinginkan dan termasuk yang diserap atau hilang yaitu :
213

f x G s x D s x (N t  1)
2

ΔPs = (Pers. 7.44, Kern)


5,22x10 10 x D e x s x s

(0,0013)x ( 53.602,7478 lb/hr.ft 2 ) 2 x (2,5833 ft) x (167,23)


=
5,22x1010 x (0,06 ft)x 1 x 1
= 0,5152 psi

SUMARRY
ho = 297,0296 h outside hio = 857,6289
Clean overall coefficient, Uc = 220,6203
Design overall coefficient, Ud = 61,6349
Dirt factor calculated , Rd = 0,0117
0,5152 Calculated P, Psi 0,6281
10,0 Allowable P, Psi 10,0