NOTES

1. EXPANSION JOINTS SHALL BE LOCATED AS SHOWN ON THE PLANS.


2. CONSTRUCTION JOINTS SHALL BE LOCATED AS REQUIRED WITH A
MAXIMUM SPACING OF 40 FEET.
3. NO CONSTRUCTION JOINT SHALL BE LOCATED CLOSER THAN 40 FEET
TO AN EXPANSION JOINT.
4. JOINTS FOR PEDESTRIAN TUNNELS SHALL INCLUDE WATERSTOPS.
5. CONTRACTION JOINTS MAY BE SUBSTITUTED FOR CONSTRUCTION
! EXPANSION JOINT JOINTS IN THE WALLS.

FIRST SECTION TO BE CAST

1" CLR. 1’-6"


MINIMUM LAP SPLICE
2" CLR. " PREFORMED
2" MINIMUM CLR.
(TYP.) JOINT FILLER

VARIES
"T"
T/2
CONSTRUCTION JOINT
PAPER TUBE SLEEVE 3’-0" DOWEL - LOCATE @ 1’-0" MAX. LAP SPLICE
FROM CORNERS AND 2’-0" MAX. LENGTH + 2"
" CHAMFER SPACES IN TOP SLAB AND WALLS PAST ! JOINT
(TYP.)
TYPICAL CONSTRUCTION JOINT
SECTION THRU WALLS & TOP SLAB (TYPICAL @ SLABS AND WALLS)
1"=1’-0"

! EXPANSION JOINT

FIRST SECTION TO BE CAST LAP SPLICE

"
"

LAP SPLICE "


LENGTH + 2" "

PAST ! JOINT

CONTRACTION JOINT
SECTION THRU BOTTOM SLAB (TYP. FOR BOTH SIDES
OF CULVERT WALLS)
EXPANSION JONT DETAILS NTS

1"=1’-0"

DESIGNED ORIGINAL
R E V I S I O N S SCALES SHOWN

NO. DATE BY DESCRIPTION


DESIGN CHECKED
ARE FOR 34" X 22"
SIGNED BY:
IDAHO D
IAHO
English CULVERT JOINT DETAILS BRIDGE PLANS
PRINTS ONLY

TRANSPORTATION BRIDGE LRFD MANUAL,


TRANSP

NT

CADD FILE NO. PROJECT NO.


ME

DETAILED PAGE B12.1


RT
OR

\prj00000\bridge\
DEPARTMENT T
A

AT P COUNTY KEY NO.


ION DE
DWG. CHECKED
b12_1.dgn

DRAWING DATE: DATE SIGNED:DATE BRIDGE DRAWING NO. SHEET


CORRECTIONS

JUNE 2006 DATE:


ORIGINAL STORED AT ITD BRIDGE SECTION OF