Beruflich Dokumente
Kultur Dokumente
Safety Notices
Product Damage
II
instrument in the presence of flammable gases or
fumes.
III
Symbols
Dangerous voltage.
Protective ground.
IV
warranty period, Deviser Instruments Inc will, at its
option, either repair or replace products which prove to
be defective.
V
execute its programming instructions when properly
installed on that instrument. Deviser Instruments Inc
does not warrant that the operation of the instrument,
or software, or firmware will be uninterrupted or
error-free but strives to insure the best operating
condition as per specifications and datasheets.
LIMITATION OF WARRANTY
VI
NO OTHER WARRANTY IS EXPRESSED OR IMPLIED.
DEVISER INSTRUMENTS INC SPECIFICALLY DISCLAIMS
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.
VII
Catalog
1 Maintenance and Safety Considerations .......1
2 Terminology ...................................................6
3 General Introduction......................................9
4 Introduction .................................................15
VIII
4.1 Appearance ...........................................15
4.2 Keypad ..................................................18
4.2.1 Soft keys.........................................19
4.2.2 Shortcut keys .................................19
4.2.3 Alphabet/Number Input ................20
4.3 Display Description ...............................21
6 Setup ............................................................86
9 Specification ...............................................124
10 Standard Accessories..............................128
XII
DS2460T-ISDB Operation Manual
2
DS2460T-ISDB Operation Manual
3
DS2460T-ISDB Operation Manual
5
DS2460T-ISDB Operation Manual
2 Terminology
BER Bit Error Rate
CBER Channel Bit Error Rate
COFDM Coded Orthogonal Frequency Division
Multiplexing
C/N Carrier-to-Noise Ratio
CW Continuous Wave
DHCP Dynamic Host Configuration Protocol
DQPSK Differential Quadrature Reference Phase
Shift Keying
DVB-C Digital Video Broadcasting – Cable
DVB-T Digital Video Broadcasting – Terrestrial
DVB-T/H Digital Video Broadcasting-Terrestrial /
Handheld
DVB-S Digital Video Broadcasting – Satellite
DVB Digital Video Broadcasting
FSK Frequency-Shift Keying
FM Frequency Modulation
HFC Hybrid Fiber-Coaxial
6
DS2460T-ISDB Operation Manual
7
DS2460T-ISDB Operation Manual
8
DS2460T-ISDB Operation Manual
3 General Introduction
DS2460T-ISDB is new model with color screen and
high performance, which is developed for ISDB-T TV
signal analysis by Deviser. This model can measure
and display most indexes of ISDB-T (Channel Power,
MER, BER, Constellation Diagram); Analog TV
(Single-frequency Level, Carrier Level of Full Channels
Spectrum, HUM). Also DS2460T-ISDB can measure
Trunk Voltage, Battery Voltage, Spectrum Analysis and
channel Scanning.
9
DS2460T-ISDB Operation Manual
Features:
* Constellation Test
* Level Test
* Channel Scanning
* Spectrum Analysis
* Tilt
* Voltage Measurement
* Multiple User Channel Plan Setup
* File Management
* Intelligent Power Management
* Character /Numeral Input
* Multi languages
10
DS2460T-ISDB Operation Manual
11
DS2460T-ISDB Operation Manual
12
DS2460T-ISDB Operation Manual
13
DS2460T-ISDB Operation Manual
14
DS2460T-ISDB Operation Manual
4 Introduction
4.1 Appearance
RF Input Port
15
DS2460T-ISDB Operation Manual
2.8”
320x240
TFT LCD
Multi-
Function
Key
Home and Enter Button
ESC/Cancel
Key
Alpha-Numeric
Keyboard
16
DS2460T-ISDB Operation Manual
DC
LAN
Adapter
Micro USB
17
DS2460T-ISDB Operation Manual
4.2 Keypad
18
DS2460T-ISDB Operation Manual
19
DS2460T-ISDB Operation Manual
20
DS2460T-ISDB Operation Manual
Frequency
or Channel
Power or
Level
Major
Area
MER and
BER
F1 F2 F3
21
DS2460T-ISDB Operation Manual
Figure 5-1
Figure 5-2
22
DS2460T-ISDB Operation Manual
Figure 5-3
The Figure 5-1, Figure 5-2andFigure 5-3Display the
Main Menu which include all of the function icons.
Soft Keys:
F1
Open the page 1
F2
Open the page 2
F3
Open the page 3
23
DS2460T-ISDB Operation Manual
24
DS2460T-ISDB Operation Manual
Figure 5-4
2DFE
Then press the or button to select the
CHANNEL PLAN item, as Figure 5-5 show.
Figure 5-5
DS2460T-ISDB has 20 blank channel plans. If you first
time use this meter, you must choose one blank
25
DS2460T-ISDB Operation Manual
26
DS2460T-ISDB Operation Manual
Figure 5-6
Figure 5-7
In this screen, you can press F2
RENAME soft
button, then press the 0FCN
, as the Figure 5-8 show.
27
DS2460T-ISDB Operation Manual
Figure 5-8
Press F1
save the new name and quit rename
operation, F2
is backspace, to correct you input
contents, press F3
, don’t save and quit. After you
quit, continue press F3
(SELECT) to set the current
cursor position channel plan as the default channel
plan, the symbol “√” is marking on this channel plan.
Press the F1
(ENTER) or enter create or
learn channel plan function. The Figure 5-10 and
Figure 5-11 show the LEARN USER PLAN screen.
The channel name use digital or standard name. In
Figure 5-9 show the channel standard name. Press
F1
(STANDARD/DIGITAL) can switch channel name.
28
DS2460T-ISDB Operation Manual
Figure 5-9
After select one blank channel plan, we should start
learn user plan.
3. In Figure 5-7, press the soft button F1
(LEARN) to
enter learn channel plan screen, as the Figure 5-10
show. Press F1
or button to choose the
channel plan standard. DS2460T-ISDB has two default
standard: NTSC, PAL_M. Press F1
(Standard) soft
button to switch standard. If you only choose analog
TV channel, the screen display content show in Figure
5-10; if user also choose the digital TV channel, the
screen display content show in Figure 5-11.
You can define the channel plan as Analog channel
29
DS2460T-ISDB Operation Manual
Figure 5-10
Figure 5-11
30
DS2460T-ISDB Operation Manual
Figure 5-12
NOTE: The analog channels with level higher than
45dBμV and digital channel with power level higher
than 32dBμV will be enabled in standard channel
plan. Only the enabled channels will be displayed in
each measurement interface. After setup your user
channel plan, you can also enable or disable channels.
When the learning the channel plan, please keep the
power on and don’t interrupt the process, otherwise
it will create a wrong channel plan.
31
DS2460T-ISDB Operation Manual
Figure 5-13
Figure 5-14
32
DS2460T-ISDB Operation Manual
Figure 5-15
33
DS2460T-ISDB Operation Manual
Figure 5-16
Press F3
(NEXT PAGE) to look at the next page
parameter.
Figure 5-17
34
DS2460T-ISDB Operation Manual
Figure 5-18
If there is no valid channel to test, the screen will
display as the Figure 5-19 show. Now, if you want to
do any test in this function, you have to create a valid
channel.
35
DS2460T-ISDB Operation Manual
Figure 5-19
The channel list will display as the Figure 5-20 show.
2DFE
Press or to select the channel. Press
1ABC
or 3GHIA
will page up or page down the
channel list. Then press c(EDIT) enter channel
information as the Figure 5-21 show.
2DFE
Press or to select the channel
parameters, if the selected parameter could be
changed, press F1
(MODIFY) or to change.
As the Figure 5-21 show, ensuring the STATUS is
enable, the channel will be enabled. In Figure 5-20,
press button also can modify channel enable
or disable status.
36
DS2460T-ISDB Operation Manual
Figure 5-20
Figure 5-21
37
DS2460T-ISDB Operation Manual
Figure 5-22
CH INFO( F1
): Press this button will display the
channel information of this analog channel as the
Figure 5-23 show. The channel parameters also can be
modified in this screen.
38
DS2460T-ISDB Operation Manual
Figure 5-23
2DFE
The buttons and are used for switch
channels circularly. If the next channel is digital
channel, the screen will be changed. (Refer to next
section.)
FREQ( F2
): Press this button to show single
frequency measurement interface as Figure 5-24,the
user can modify the frequency, press this button again
to return.
SAVE( 4 JKL
): Press this button to save the result of
level test ,refer to Figure 5-56.
39
DS2460T-ISDB Operation Manual
Figure 5-24
40
DS2460T-ISDB Operation Manual
Figure 5-25
CH INFO( F1
): Press this button will display the
channel information of this ISDB-T channel, as the
Figure 5-26 show. The channel parameters also can be
modified in this screen.
41
DS2460T-ISDB Operation Manual
Figure 5-26
2DFE
The and are used for switching channels
circularly. If the next channel is analog channel, the
screen will be as the Figure 5-22 show.
42
DS2460T-ISDB Operation Manual
Figure 5-27
When the signal is locked, in Figure 5-27, if the
program not auto update parameters value, we can
press F2
(RENEW) to update signal parameters.
SAVE( 4 JKL
): Press this button to save the result of
level test ,refer to Figure 5-56.
FREQ( F2
): Press this button into frequency
measurement interface as Figure 5-28. In this mode,
the user can easily modify the central frequency, but
the other parameters of digital channel will be the
same as channel mode, press this button again to
return.
43
DS2460T-ISDB Operation Manual
Figure 5-28
LAYER( F3
):ISDB-T supports hierarchical transmission
by introducing hierarchical layers, which means
different services, such as HDTV, multi-channel SDTV,
and data, can be transmitted in one frequency channel.
There are 13 OFDM segments in the ISDB-T
transmission channel. Each layer consists one or more
segments and has its own transmission parameters
(e.g., the inner coding rate, modulation scheme and
time interleaving length). A maximum of 3 layers can be
provided. Press soft button F3
(LAYER) can switch
layer A, B and C. The CBER(A) or VBER (B) display
current layer.
44
DS2460T-ISDB Operation Manual
Figure 5-29
45
DS2460T-ISDB Operation Manual
Figure 5-30
46
DS2460T-ISDB Operation Manual
Figure 5-31
Figure 5-32
Soft Keys Operation:
CH INFO( F1
): Press this button to display the
current channel information, and user can modify all
of the parameters in this menu, as the Figure 5-33
47
DS2460T-ISDB Operation Manual
Figure 5-33
Figure 5-34
48
DS2460T-ISDB Operation Manual
FREQ ( F2
): Press this button to display the current
frequency POWER, MER, BER (CBER and VBER) and
constellation diagram, press this button again to
return.
49
DS2460T-ISDB Operation Manual
2DFE
The and buttons are used for switching
digital channels circularly.
Figure 5-35
50
DS2460T-ISDB Operation Manual
Figure 5-36
In Figure 5-36, press F3
to enter the tilt channels
setup menu, select the channels that you want to do
51
DS2460T-ISDB Operation Manual
2DFE
tilt test as Figure 5-37; press the and
button to change the highlight line, and then press
the to select or unselect the channel.
Here, the 1ABC
and 3GHIA
button have been defined
to page up and page down the channel list.
The "√" means this channel is selected. If you want to
cancel this selection, please press again and "√"
will disappeared. The channel No. of all channels
selected will be saved and displayed at the left blocks
Figure 5-37
After selected,Press F3
to return to Tilt/Level
measurement interface. Now the Tilt measurement
can be continued.
52
DS2460T-ISDB Operation Manual
Figure 5-38
Soft Keys Operation
LIST( F1
): Press LIST soft key to enter level list mode,
as Figure 5-39.
53
DS2460T-ISDB Operation Manual
Figure 5-39
SAVE ( F2
):Press 4JKL
key and enter into Figure
5-56to save the result of tilt test ,refer to5.13.2.
SETUP( F3
):When testing, press SETUP soft key and
enter into Figure 5-37 to re-select tested channels.
54
DS2460T-ISDB Operation Manual
Press F1
to switch the modes between Tilt Graph
and level list. In level list mode, you can easily get
level value of the channels tested, as Figure 5-39.
LIST( F1
): Press GRAPH soft key to enter Tilt mode,
as Figure 5-38.
SAVE ( F2
):Press SAVE soft key and enter into Figure
5-56 to save the result of tilt test ,refer to5.13.2.
SETUP( F3
):When testing, press SETUP soft key and
enter into Figure 5-37to re-select tested channels.
55
DS2460T-ISDB Operation Manual
56
DS2460T-ISDB Operation Manual
Figure 5-40
57
DS2460T-ISDB Operation Manual
58
DS2460T-ISDB Operation Manual
VIEW: Press F3
to find the next page soft button
menu, show as the Figure 5-41, press the F1
(VIEW)
multi times and the zoom times circulation display
between ×1, ×2, ×3, ×4 and ×5.
×1: Max display 30 channels in the screen.
×2: Max display 50 channels in the screen.
×3: Max display 75 channels in the screen.
×4: Max display 150 channels in the screen.
×5: Max display 255 channels in the screen.
SCALE: In Figure 5-41, press F2
(SCALE) multi times ,
and the scale circulation display between 1dB, 2dB,
59
DS2460T-ISDB Operation Manual
Figure 5-41
SAVE: Press 4JKL
button and enter into Figure 5-56
to save the result of tilt test ,refer to 5.13.2.
STOP( F1
): Press STOP soft key, the scanning will
stop, and you can continue the scanning by pressing it
again.
60
DS2460T-ISDB Operation Manual
Figure 5-42
The DS2460T-ISDB has two types spectrum analysis
modes: normal spectrum analysis and fast spectrum
analysis. The fast spectrum analysis mode allow
technician viewing 5~1220MHz, the normal spectrum
analysis mode sweep speed lower than fast spectrum
analysis mode, but it has better amplitude accurate.
61
DS2460T-ISDB Operation Manual
62
DS2460T-ISDB Operation Manual
Figure 5-43
The DS2460T-ISDB has two types spectrum analysis
modes: normal spectrum analysis and fast spectrum
analysis. The fast spectrum analysis mode allow
technician viewing 5~1220MHz, the normal spectrum
analysis mode sweep speed lower than fast spectrum
analysis mode, but it has better amplitude accurate.
63
DS2460T-ISDB Operation Manual
64
DS2460T-ISDB Operation Manual
Figure 5-44
65
DS2460T-ISDB Operation Manual
50Hz/60Hz( F1
):After pressing 50Hzor 60Hzsoft key,
the DS2460T-ISDB will select the frequency of system
power as Figure 5-45.
Figure 5-45
2DFE
The buttons and are used to switch
analog channels circularly. Also you can input the
channel number using the character/digit keys (need use
0FCN
button).
66
DS2460T-ISDB Operation Manual
Figure 5-46
67
DS2460T-ISDB Operation Manual
Figure 5-47
Press F1
(GRAPH)to graph display test results
screen, as show in Figure 5-48.
68
DS2460T-ISDB Operation Manual
Figure 5-48
Press F1
(LIST) again to view the test result LIST as
Figure 5-49.Press F3
(RETEST) can do limit test once
again. Section 6.4.4 describe limit setup and edit
detailed information.
Figure 5-49
69
DS2460T-ISDB Operation Manual
Figure 5-50
To measure C/N Ratio with your DS2460, you must
set-up the video carrier frequency and noise
bandwidth correction correctly. Noise bandwidth is
different depending on the channel bandwidth, which
depends on your location. (NA, or EU). NTSC-M
system uses 4MHz noise bandwidth correction. PAL-D
70
DS2460T-ISDB Operation Manual
Press F2
(BW) and 0FCN
can edit and input new
bandwidth value. As show in the Figure 5-51.
Figure 5-51
71
DS2460T-ISDB Operation Manual
72
DS2460T-ISDB Operation Manual
Figure 5-52
If user want to start PING test, user must setup the
DS2460T-ISDB network address. As show in the Figure
5-53. If you want to directly PING web site domain
name, you must configure the DNS server IP address.
If you don’t configure the DNS server IP address, you
only can PING IP address.
73
DS2460T-ISDB Operation Manual
Figure 5-53
The PING function parameters introduction.
HOST ADDRESS: Input the network address or the
desired IP address to be tested in the host address
box at the top (for example: www.google.com).
PACKET COUNT: the number of data packets sent by
the assigned PING order.
UNLIMITED: if this box is checked, the PING function
will be continuous until the test is interrupted by
pressing the stop button.
PACKET LENGHT: the package length: of the PING
request
INTERVAL: time interval delay between ping packets,
74
DS2460T-ISDB Operation Manual
in ms.
Figure 5-54
Figure 5-55
75
DS2460T-ISDB Operation Manual
76
DS2460T-ISDB Operation Manual
Figure 5-56
77
DS2460T-ISDB Operation Manual
Figure 5-57
78
DS2460T-ISDB Operation Manual
Figure 5-58
Figure 5-59
79
DS2460T-ISDB Operation Manual
Figure 5-60
Normally, the data items can be opened using LIST
2DFE
mode( F1
), press or to select the data
item or press F2
(PRE PAGE)/ F3
(NEXT PAGE)to
select data item in LIST mode as show in Figure 5-61,
80
DS2460T-ISDB Operation Manual
Figure 5-61
Figure 5-62
81
DS2460T-ISDB Operation Manual
Figure 5-63
Figure 5-64
82
DS2460T-ISDB Operation Manual
Figure 5-65
83
DS2460T-ISDB Operation Manual
Figure 5-66
Press (ENTER) F1
in Figure 5-66, the file will be
deleted as Figure 5-67.
84
DS2460T-ISDB Operation Manual
Figure 5-67
85
DS2460T-ISDB Operation Manual
6 Setup
Figure 6-1
86
DS2460T-ISDB Operation Manual
87
DS2460T-ISDB Operation Manual
6.2 Information
Figure 6-2
88
DS2460T-ISDB Operation Manual
6.3 General
Figure 6-3
89
DS2460T-ISDB Operation Manual
Figure 6-4
Note:Contact Deviser for more languages.
90
DS2460T-ISDB Operation Manual
Figure 6-5
91
DS2460T-ISDB Operation Manual
Figure 6-6
92
DS2460T-ISDB Operation Manual
Figure 6-7
If user want to open one option, he must ensure the
related hardware also install in DS2460T-ISDB. If the
related option’s hardware has installed in the
DS2460T-ISDB, the user only need contact with the
sales, get the option’s password, then open the Figure
6-7 interface, press the F1
(SETUP) to open the
93
DS2460T-ISDB Operation Manual
Figure 6-8
Figure 6-9
94
DS2460T-ISDB Operation Manual
6.3.6 Network
Figure 6-10
95
DS2460T-ISDB Operation Manual
Figure 6-11
The Figure 6-12 show the PING measurement
snapshot.
Figure 6-12
96
DS2460T-ISDB Operation Manual
Figure 6-13
97
DS2460T-ISDB Operation Manual
6.4.2 TP Compensation
Figure 6-14
The typical optical receiver test point loss is 20dB, if
so, the user can input the required TEST POINT
compensation. (20dB in this example) Some probes
along with specific length of cables may account for
1.5dB loss (in this example), the user can input that
98
DS2460T-ISDB Operation Manual
99
DS2460T-ISDB Operation Manual
Figure 6-15
100
DS2460T-ISDB Operation Manual
Figure 6-16
101
DS2460T-ISDB Operation Manual
Figure 6-17
Figure 6-18
102
DS2460T-ISDB Operation Manual
Table 6-1
Item Limit
Minimum Video level 60dBμV
Maximum Video level 100dBμV
Minimum △ V/A 10dB
Maximum △ V/A 20dB
Maximum VID 10 dB
Maximum VID DEV 3 dB
Table 6-2
Item Limit
Minimum Video level 30~99dBμV
Maximum Video level 31~120dBμV
Minimum △ V/A 0~19dB
Maximum △ V/A 1~30dB
Maximum VID 1~30 dB
Maximum VID DEV 1~20 dB
103
DS2460T-ISDB Operation Manual
Table 6-3
Item Limit
Minimum Power level 50dBμV
Maximum Power level 90dBμV
Minimum MER 32dB
Maximum PRE-BER 1.0E-9
Maximum POST-BER 1.0E-9
Table 6-4
Item Limit
Minimum Power level 25~89dBμV
Maximum Power level 26~110dBμV
Minimum MER 20~40dB
CBER 1.0E-3~1.0E-9
VBER 1.0E-3~1.0E-9
104
DS2460T-ISDB Operation Manual
Table 6-5
Item Limit
Minimum Tilt Delta 10dB
Maximum Noise 30dBμV
Table 6-6
Item Limit
Minimum Tilt Delta 0~30dB
Maximum Noise -10~30dBμV
To set the test limit, you can press the 1ABC
and 3GHIA
105
DS2460T-ISDB Operation Manual
106
DS2460T-ISDB Operation Manual
Figure 6-19
107
DS2460T-ISDB Operation Manual
Figure 6-20
108
DS2460T-ISDB Operation Manual
Trunk Voltage
This meter will automatically judge whether it is AC or
DC in the trunk, and display the trunk voltage on the
screen as Figure 6-21 show.
Figure 6-21
109
DS2460T-ISDB Operation Manual
Temperature Inside
DS2460T-ISDB can monitor inside temperature itself,
and display Celsius or Fahrenheit at the same time,
refer to Figure 6-22.
Figure 6-22
110
DS2460T-ISDB Operation Manual
Figure 6-23
111
DS2460T-ISDB Operation Manual
Figure 6-24
112
DS2460T-ISDB Operation Manual
Figure 6-25
113
DS2460T-ISDB Operation Manual
Figure 6-26
114
DS2460T-ISDB Operation Manual
Figure 6-27
115
DS2460T-ISDB Operation Manual
116
DS2460T-ISDB Operation Manual
Figure 6-28
EDIT USER PLAN will show the channels list on the
screen as Figure 6-28, you can only exit this function
2DFE
by press the (HOME) key, press or
to highlight one channel, and press F3
(EDIT)to edit
channel parameters as Figure 6-29.
Figure 6-29
117
DS2460T-ISDB Operation Manual
Figure 6-30
118
DS2460T-ISDB Operation Manual
Figure 6-31
119
DS2460T-ISDB Operation Manual
7 Power Supply
7.1 Battery
NOTE:
120
DS2460T-ISDB Operation Manual
7.2 Charging
NOTE:
The instrument can’t be charged in the temperature
beyond 10℃~35℃, otherwise the battery life will be
shorten.
121
DS2460T-ISDB Operation Manual
8 Port
The instrument can communicate with a PC through
the Micro USB communication port. Refer to Figure
8-1 and Figure 8-2.
123
DS2460T-ISDB Operation Manual
9 Specification
Normal Spectrum Analysis
Frequency 45MHz~1052MHz
Range
Span 2.5MHz, 6.25MHz, 12.5MHz, 25MHz,
62.5MHz, Full Span
Fast Spectrum Analysis
Frequency 5MHz~1220MHz
Range
Span 12.5MHz, 25MHz, 62.5MHz, Full
Span
Channel Scan
Number of 160 channels max
Channels
Scale 1,2,5,10dB/div
Zoom 1X,2X,3X,4X,5X five levels
Analog TV
Support PAL, NTSC and FM Radio (Single
Standard Frequency)
124
DS2460T-ISDB Operation Manual
125
DS2460T-ISDB Operation Manual
Power Level
Accuracy ±2.0dB(C/N>20dB)
MER
Measurement > 40dB
MER Accuracy ±2.0dB
CBER 1E-1~1E-5
VBER 1E-1~1E-7
Constellation √
Line Voltage Measurement
Range 0V to 100V (AC/DC) with accuracy
±2V
Others
RF Input 75Ω
USB USB Micro B 2.0
Ethernet 10/100M
Display 2.8” 320x240 TFT LCD
AC/DC AC 100V to 240V 50-60Hz ,DC
Adapter 15V/0.9A
Battery 7.4V 2.5Ah Lithium Battery
126
DS2460T-ISDB Operation Manual
127
DS2460T-ISDB Operation Manual
10 Standard Accessories
Standard Accessories Quantity
DS2460T-ISDB 1
AC-DC power adapter/charger 1
Carrying bag 1
F connect 2
Manual and Toolbox software CD 1
128
DS2460T-ISDB Operation Manual
129
DS2460T-ISDB Operation Manual
22 521.143
F 23 527.143
24 533.143
25 539.143
26 545.143
27 551.143
28 557.143
29 563.143
30 569.143
31 575.143
32 581.143
33 587.143
34 593.143
35 599.143
36 605.143
37 611.143
38 617.143
39 623.143
40 629.143
130
DS2460T-ISDB Operation Manual
41 635.143
U 42 641.143
43 647.143
44 653.143
H 45 659.143
46 665.143
47 671.143
F 48 677.143
49 683.143
50 689.143
51 695.143
52 701.143
53 707.143
54 713.143
55 719.143
56 725.143
U
57 731.143
58 737.143
59 743.143
131
DS2460T-ISDB Operation Manual
H 60 749.143
61 755.143
62 761.143
F 63 767.143
64 773.143
65 779.143
66 785.143
67 791.143
68 797.143
69 803.143
132
DS2460T-ISDB Operation Manual
Deviser(US)
Address:780 Montague Expressway,
Suite 701, San Jose, CA 95131, USA
Tel:+1 408 955 0938
http://www.deviserinstruments.com
E-mail:info@deviserinstruments.com
Deviser (China)
Address: No.8,Haitai Chuangxin 3rd Road,
Hi-tech Industrial Development Area,
Tianjin, China, 300392
Tel: +86 22 2764 5003 ext.803
http://www.deviserinstruments.com
E-mail: overseasbiz@deviser.com.cn
133