PATROL-101 combined FEATURES DETECTOR INSTALLATION 3.
Run the installation wire
™ detector designed for use MANUAL through detector back cover. PATROL - 101 in open, outdoor areas and · DUAL TECHOLOGY PIR & MW 1. Run the installation wire 4. Mount back cover of the low-temperature environments detector to the bracket using WEATHERPROOF through the bracket wiring to -55°С. · QUAD ELEMENT four screws. CURTAIN PIR & MW PYRO SENSOR hole. DETECTOR FOR 2. Mount bracket onto the wall 5. Insert the PCB and connect PATROL-101 creates a · BUILT-IN HEATER wires according to the OUTDOOR USE and affix with screws, using narrow protective curtain schematic. · SHOCK SENSOR the knockouts. allowing free movement within 6. Close front cover and affix the protected area without · ANTI-MASK PROTECTION Corner installation Wall installation with screw. triggering the alarm. · DOPPLER PULSE-COUNT SELECTION (1-7) PATROL-101 with anti-mask technology, to detect all types · INDIVIDUAL PIR / MW/ of masking attempts. ANTI-MASK SENSITIVITY ADJUSTMENT
PATROL-101 provides pet · IMMUNE TO PETS UP TO 30KG
immune detection up to 30kg. · AUTOMATIC TEMPERATURE COMPENSATION · VISIBLE LIGHT DISTURBANCE PROTECTION
· DOUBLE RFI/EMI PROTECTION
· WEATHERPROOF HOUSING
1 2 3 4 5
TERMINAL BLOCK PATROL-101 MOUNTING
CONNECTION OPTIONS Detector can be installed vertically or horizontally (see illustration). Recommended installation Terminals “+12V-“ – for height is 2.5m. Maximum connection to the power installation height is 5m. supply of the control unit. * For installation over 3.5m, 15 Terminals “Tamper” – mount the detector at an angle ME TE R for connection to a 24-hour of 20 degrees. S
zone in the control unit. where direct sunlight can enter DETECTION AREA Terminals “Relay 1” – the pyro sensor. PIR detector relay output. Terminals “Relay 2”– anti-mask relay output. Terminals +12V- (H) – heater power connects to external 12-16V/1A power unit. IMPORTANT! When connecting the heater, take into consideration voltage drop and power loss in cables. 6 7 8 9 10 SHOCK SENSOR 1. POWER SUPPLY CONNECTION PIR ADJUSTMENT MW ADJUSTMENT PATROL-101 includes a shock 2. JUMPER TO SELECT NC/NO 1. Remove the front cover. 1. Remove the front cover. sensor that detects external 3. MW SENSITIVITY ADJUSTMENT attack. Any physical impact or 2. Connect the power and 2. Set Jumper W1 to the attempt to separate the detector 4. SHOCK SENSOR wait for LED to stop flashing "MW TEST" position, from the wall will trigger an 5. ON/OFF SHOCK SENSOR (warm-up time 50 sec). RELAY 1 is open. alarm signal to the control JUMPER 3. Replace the cover. panel through the terminal 3. Set Jumper W1 to the 6. ANIMAL WEIGHT JUMPER «TAMPER». "PIR TEST" position, RELAY 1 4. Use the "MW SENSITIVITY" 7. ON/OFF LED JUMPER is open. Jumper W5 enables/disables potentiometer to adjust the MW the shock sensor. 8. PIR SENSITIVITY ADJUSTMENT sensitivity, moving within the 4. Replace the cover. protected area. · Jumper W5 On - Shock 9. OPERATING MODE SETTING The blue LED should flash Sensor activated. 10. ANTI-MASK SENSITIVITY 5. Use the "PIR SENSITIVITY" with each step. · Jumper W5 OFF - Shock ADJUSTMENT potentiometer to adjust the Sensor disabled. PIR sensitivity, moving within 11. PULSE PROGRAMMING JUMPER the protected area. The red LED should flash with each 12. MW ANTENNA step. 13. HEATER POWER SUPPLY CONNECTION 14. ANTI MASK RELAY OUTPUT (RELAY 2) 15. PIR DETECTOR RELAY OUTPUT (RELAY 1)
SWITCH CONNECTIONS SPECIFICATIONS ………..NC/NO; 60В; 100mА; 16Ω 1. Set Jumper W1 to "WORK" GSN Electronic Company Ltd. Anti-mask alarm activation position. 1. Disconnect the power. Input voltage……………….9 – 16V delay:…………………......40-60sec warrants the product to be free Current consumption: from defects in materials and 2. Set Jumper W6 according 2. Set Jumper W4 to "ON" Alarm period:…......................3sec In standby mode: …………...80mA workmanship under condition to animal weight. position. In alarm mode:……………..120mА Reset time:………………..5 ± 1sec of observance of service 3. Replace the cover – LED 3. Restore power. Heater input voltage….....12 – 14V Pulse counting:……...............1 – 7 regulations and to be repaired will blink. At the same time, or replaced under absence of Heater current Installation height:………..2.5 – 5m mechanical damages for a keep the detector field-of-view PULSE-COUNTING METHOD consumption:……………….700mA clear, until the LED stops Light immunity:……………………... limited period of five years blinking – the anti-mask Selectable pulse count 1, 2, 3, 4, Microwave frequency:...10.525GHz …………….no less than 30000 lux from the date of sale. function will then be activated 5, 6 or 7 provides users with the Anti-mask startup (boot) Operating temperature range: correctly. option of optimizing detector period:……………..…… 50 ± 5sec without heater ………–30°C +60°C Use the “ANTIMASK sensitivity to suit the with heater ………....– 55°C +60°C environment, thus retaining Adjustable mask SENSITIVITY” potentiometer detection:……………….0.2 –20cm Storage temperature to adjust anti-mask sensitivity. reliable performance at all times. range:....................– 60°C – +80°C To adjust pulse count for Warm up period:…..……50 ± 5sec 4. Affix the cover with screw. specific operating environments: Detection range:…...……15meters Protection rating………………IP65
1. Remove Jumper W3. RFI immunity: 30V/м
Detection speed at a frequency range 30MHz-2GHz The blue LED blinks indicating range:………………..0.2 – 4 m/sec that pulse counting has begun. EMI immunity……………..50,000V Relay output:………………………. ………...NC/NO; 60V; 100mA; 16Ω Dimensions:………………………... 2. Replace Jumper W3 during …………..55mm x 49mm x 153mm pause between LED blinking. Tamper output:…........................... ……………..NC; 60V; 100mА; 16Ω Weight:…………….…………270gr. P/N: USMEPAT101REV.A