PATROL-101 combined FEATURES DETECTOR INSTALLATION 3.

Run the installation wire


™ detector designed for use MANUAL through detector back cover.
PATROL - 101 in open, outdoor areas and · DUAL TECHOLOGY
PIR & MW 1. Run the installation wire 4. Mount back cover of the
low-temperature environments detector to the bracket using
WEATHERPROOF through the bracket wiring
to -55°С. · QUAD ELEMENT four screws.
CURTAIN PIR & MW PYRO SENSOR
hole.
DETECTOR FOR 2. Mount bracket onto the wall 5. Insert the PCB and connect
PATROL-101 creates a · BUILT-IN HEATER wires according to the
OUTDOOR USE and affix with screws, using
narrow protective curtain schematic.
· SHOCK SENSOR the knockouts.
allowing free movement within 6. Close front cover and affix
the protected area without · ANTI-MASK PROTECTION Corner installation Wall installation with screw.
triggering the alarm.
· DOPPLER PULSE-COUNT
SELECTION (1-7)
PATROL-101 with anti-mask
technology, to detect all types · INDIVIDUAL PIR / MW/
of masking attempts. ANTI-MASK SENSITIVITY
ADJUSTMENT

PATROL-101 provides pet · IMMUNE TO PETS UP TO 30KG


immune detection up to 30kg. · AUTOMATIC TEMPERATURE
COMPENSATION
· VISIBLE LIGHT DISTURBANCE
PROTECTION

· DOUBLE RFI/EMI PROTECTION


· WEATHERPROOF HOUSING

1 2 3 4 5

TERMINAL BLOCK PATROL-101 MOUNTING


CONNECTION OPTIONS
Detector can be installed
vertically or horizontally
(see illustration).
Recommended installation
Terminals “+12V-“ – for height is 2.5m. Maximum
connection to the power installation height is 5m.
supply of the control unit. * For installation over 3.5m, 15
Terminals “Tamper” – mount the detector at an angle ME
TE
R
for connection to a 24-hour of 20 degrees. S

normally closed protective NOTE! Avoid installing detector


zone in the control unit. where direct sunlight can enter DETECTION AREA
Terminals “Relay 1” – the pyro sensor.
PIR detector relay output.
Terminals “Relay 2”–
anti-mask relay output.
Terminals +12V- (H) – heater
power connects to external
12-16V/1A power unit.
IMPORTANT!
When connecting the heater,
take into consideration voltage
drop and power loss in cables.
6 7 8 9 10
SHOCK SENSOR 1. POWER SUPPLY CONNECTION PIR ADJUSTMENT MW ADJUSTMENT
PATROL-101 includes a shock 2. JUMPER TO SELECT NC/NO 1. Remove the front cover. 1. Remove the front cover.
sensor that detects external 3. MW SENSITIVITY ADJUSTMENT
attack. Any physical impact or 2. Connect the power and 2. Set Jumper W1 to the
attempt to separate the detector 4. SHOCK SENSOR wait for LED to stop flashing "MW TEST" position,
from the wall will trigger an 5. ON/OFF SHOCK SENSOR (warm-up time 50 sec). RELAY 1 is open.
alarm signal to the control JUMPER 3. Replace the cover.
panel through the terminal 3. Set Jumper W1 to the
6. ANIMAL WEIGHT JUMPER
«TAMPER». "PIR TEST" position, RELAY 1 4. Use the "MW SENSITIVITY"
7. ON/OFF LED JUMPER is open.
Jumper W5 enables/disables potentiometer to adjust the MW
the shock sensor. 8. PIR SENSITIVITY ADJUSTMENT sensitivity, moving within the
4. Replace the cover. protected area.
· Jumper W5 On - Shock 9. OPERATING MODE SETTING
The blue LED should flash
Sensor activated. 10. ANTI-MASK SENSITIVITY 5. Use the "PIR SENSITIVITY"
with each step.
· Jumper W5 OFF - Shock ADJUSTMENT potentiometer to adjust the
Sensor disabled. PIR sensitivity, moving within
11. PULSE PROGRAMMING
JUMPER
the protected area. The red
LED should flash with each
12. MW ANTENNA step.
13. HEATER POWER SUPPLY
CONNECTION
14. ANTI MASK RELAY OUTPUT
(RELAY 2)
15. PIR DETECTOR RELAY
OUTPUT (RELAY 1)

11 12 13 14 15

OPERATION MODE CHANGING RELAY TECHNICAL Anti-mask Relay output:………….. WARRANTY:


SWITCH CONNECTIONS SPECIFICATIONS ………..NC/NO; 60В; 100mА; 16Ω
1. Set Jumper W1 to "WORK" GSN Electronic Company Ltd.
Anti-mask alarm activation
position. 1. Disconnect the power. Input voltage……………….9 – 16V
delay:…………………......40-60sec warrants the product to be free
Current consumption: from defects in materials and
2. Set Jumper W6 according 2. Set Jumper W4 to "ON" Alarm period:…......................3sec
In standby mode: …………...80mA workmanship under condition
to animal weight. position.
In alarm mode:……………..120mА Reset time:………………..5 ± 1sec of observance of service
3. Replace the cover – LED 3. Restore power. Heater input voltage….....12 – 14V Pulse counting:……...............1 – 7 regulations and to be repaired
will blink. At the same time, or replaced under absence of
Heater current Installation height:………..2.5 – 5m mechanical damages for a
keep the detector field-of-view PULSE-COUNTING METHOD consumption:……………….700mA
clear, until the LED stops Light immunity:……………………... limited period of five years
blinking – the anti-mask Selectable pulse count 1, 2, 3, 4, Microwave frequency:...10.525GHz …………….no less than 30000 lux from the date of sale.
function will then be activated 5, 6 or 7 provides users with the
Anti-mask startup (boot) Operating temperature range:
correctly. option of optimizing detector period:……………..…… 50 ± 5sec without heater ………–30°C +60°C
Use the “ANTIMASK sensitivity to suit the with heater ………....– 55°C +60°C
environment, thus retaining Adjustable mask
SENSITIVITY” potentiometer detection:……………….0.2 –20cm Storage temperature
to adjust anti-mask sensitivity. reliable performance at all times.
range:....................– 60°C – +80°C
To adjust pulse count for Warm up period:…..……50 ± 5sec
4. Affix the cover with screw. specific operating environments: Detection range:…...……15meters Protection rating………………IP65

1. Remove Jumper W3. RFI immunity: 30V/м


Detection speed
at a frequency range 30MHz-2GHz
The blue LED blinks indicating range:………………..0.2 – 4 m/sec
that pulse counting has begun. EMI immunity……………..50,000V
Relay output:……………………….
………...NC/NO; 60V; 100mA; 16Ω Dimensions:………………………...
2. Replace Jumper W3 during
…………..55mm x 49mm x 153mm
pause between LED blinking. Tamper output:…...........................
……………..NC; 60V; 100mА; 16Ω Weight:…………….…………270gr.
P/N: USMEPAT101REV.A

16 17 18 19 20