Technical Specification
CEFO G2 T1 CEFO G2 T2
Table of Contents
1 – Introduction .................................................................................................................................................................... 03
2 – Description ..................................................................................................................................................................... 04
3 – Settings .......................................................................................................................................................................... 05
4 – Sizes .............................................................................................................................................................................. 06
5 – Characteristics ............................................................................................................................................................... 07
5.1 – General Characteristics ........................................................................................................................................ 07
5.2 – Mechanical Characteristics .................................................................................................................................... 08
5.2.1 – Air-tightness ........................................................................................................................................................ 08
5.2.2 – Bending .............................................................................................................................................................. 08
5.2.3 – Twist ................................................................................................................................................................ 09
5.2.4 – Pull .................................................................................................................................................................... 09
5.2.5 – Vibration .............................................................................................................................................................. 10
5.2.6 – Impact ................................................................................................................................................................. 10
5.2.7 – Compression ..................................................................................................................................................... 10
5.2.8 – Water Immersion .............................................................................................................................................. 11
5.2.8 – Attenuation Variation after housing the fiber in the case ................................................................................... 11
5.3 – Mechanical Characteristics .................................................................................................................................. 12
5.3.1 – Saline Mist ...................................................................................................................................................... 12
5.3.2 – Water Protection ............................................................................................................................................... 12
5.3.3 – Temperature Variation ....................................................................................................................................... 13
5.3.4 – Accelerated Weathering ................................................................................................................................... 14
5.3.5 – Resistance to Chemical Attack .......................................................................................................................... 14
6 – Purchase Unit ............................................................................................................................................................... 15
7 – Packaging and Transport ............................................................................................................................................. 15
8 – Quality Assurance ......................................................................................................................................................... 15
9 – Notes .............................................................................................................................................................................. 15
1 - Introduction This specification is intended to define the manufacturing and use for the
Set of Optical Splicing Box (CEFO G2).
For this purpose, items describing information about the purpose and
operation of the product, main sizes of the components and settings.
2 - Description The set of optical splicing box CEFO G2 has been developed to house
and protect splices of optical fiber cables in aerial and ground networks.
CEFO G2 is a compact easy-to-use product that has high resistance
against deterioration and weather.
1. Dome: Responsible for protection of the splice set. The plastic raw-
material used is polypropylene. It has characteristics that provides the
product with high resistance against deterioration when exposed to long
periods in the environment; including the action of ultraviolet (UV).
3. Cover and Tray: Responsible for housing splices. The plastic raw-
material used in both is the high impact polystyrene gives these
resistance against deterioration.
4. Metal parts: The metal parts of the splices, screws, washers, fasteners
are composed of stainless steel and aluminum.
3 – Settings CEFO G2 has different settings that vary according to the number of fibers
per tray, amounts of trays, tray type, dome size and fastening (aerial or
underground).
Number of
Model Number of fibers Number Customers who accept Customers who accept
trays Model
of trays 12 fibers per tray 24 fibers per tray
CEFO G2 T2 01B2 1 Up to 24 fibers
CEFO G2 T1 01B3 1 Up to 12 fibers Up to 24 fibers
CEFO G2 T2 02B2 2 From 24 to 48 fibers
CEFO G2 T1 02B3 2 From 12 to 24 fibers From 24 to 48 fibers
CEFO G2 T2 03B2 3 From 24 to 72 fibers
CEFO G2 T1 03B3 3 From 12 to 36 fibers From 24 to 72 fibers
CEFO G2 T2 04B2 4 From 24 to 96 fibers
CEFO G2 T2 05B2 5 From 24 to 120 fibers CEFO G2 T1 04B3 4 From 12 to 48 fibers From 24 to 96 fibers
CEFO G2 T2 06B2 6 From 24 to 144 fibers CEFO G2 T1 05B3 5 From 12 to 60 fibers From 24 to 120 fibers
CEFO G2 T2 07B2 7 From 24 to 168 fibers CEFO G2 T1 06B3 6 From 12 to 72 fibers From 24 to 144 fibers
CEFO G2 T2 08B2 8 From 24 to 192 fibers CEFO G2 T2 01B3 1 Up to 12 fibers Up to 24 fibers
CEFO G2 T2 09B2 9 From 24 to 216 fibers CEFO G2 T2 02B3 2 From 12 to 24 fibers From 24 to 48 fibers
CEFO G2 T2 10B2 10 From 24 to 240 fibers CEFO G2 T2 03B3 3 From 12 to 36 fibers From 24 to 72 fibers
CEFO G2 T2 11B2 11 From 24 to 264 fibers CEFO G2 T2 04B3 4 From 12 to 48 fibers From 24 to 96 fibers
CEFO G2 T2 12B2 12 From 24 to 288 fibers
CEFO G2 T2 05B3 5 From 12 to 60 fibers From 24 to 120 fibers
CEFO G2 T2 06B3 6 From 12 to 72 fibers From 24 to 144 fibers
C D
A B (width supported by (width supported by
ropes) ropes)
CEFO G2 T1 553 285 292 311
CEFO G2 T2 650 285 292 311
5 – Characteristics
5.2 – Mechanical
Characteristics
Requirements:
5.2.1 – Air-tightness: When subject to the test for second characteristic numeral 7, according to
ABNT NBR IEC 60529, optical terminal box must not show the entry of
water.
Procedure:
- Immerse the test specimen in a tank with water with enough height to cover
it with at least 0.15 m of water, leaving the ends of the cables outwards of the
water.
- The water to be used must be dyed with fluorescein sodium, and the
concentration of the mixture is in the range of 0.01% to 0.1%.
- After 30 minutes, the sealed air optical terminal box must be removed and
thoroughly dried.
- Being externally dry, the aerial optical terminal box must be opened and
examined internally with ultraviolet light source, and checked for possible
contamination fluorescent, which will reveal the water penetration.
Procedure:
When it is run 2 cycles of bending in each cable, with angle ranging from -30°
to +30° related to its normal position, in each of the two mutually
perpendicular axes.
Procedure:
- Loads for application in cables: As table 1 of IEC 61300-2-5.
- Twist distance: 400 mm of the cable entry in the terminal box.
- Cycle Duration: 10 min, with a permanence time of 5 min at -90° and +90°.
Procedure:
- Loads to be applied to the cables:
Main cable: 440 N.
Drop cables: 100 N.
- Load application time: 2 hours in each cable.
Procedure:
- Frequency: 10 Hz to 55 Hz.
- Cycle Duration: 10 Hz to 55 Hz returning to 10 Hz in approximately 1
minute.
- Amplitude: 0.76 mm (1.52 mm peak-to-peak).
Number of Cycles: 360.
- Time: 2 hours in each of the mutually perpendicular plans.
- During the test, the attenuation must be measured with maximum intervals
of 20 s.
Procedure:
Submit the box to an impact of a steel ball of 1 kg at a height of 1 m.
Procedure:
When applied a load of 1,000 N to an area not less than 25 cm2 of the main
face during 10 minutes.
Procedure:
- The underground optical terminal box must undergo a hydrostatic pressure
of 0.6 m of the water column for 7 hours.
- The water to be used must be dyed with fluorescein sodium, and the
concentration of the mixture is in the range of 0.01% to 0.1%.
After 7 days, the underground terminal box has to be removed and carefully
wiped.
- Being dry, the underground optical terminal box must be opened and
examined internally with ultraviolet light source, and be checked for possible
contamination fluorescent, which will reveal the water penetration.
Procedure:
- Mount the optical fibers inside the case, using its maximum capacity, with
the procedures defined by the manufacturer in the product documentation.
5.3 – Mechanical
Characteristics
Procedure:
The optical terminal box must be subject to 360 hours of exposure to saline
mist.
Procedure:
When undergoing artificial rain test with a precipitation rate of 1.0 mm/min to
2.0 mm/min for each component (vertical and horizontal). It is allowed to
measure the vertical component of the rain, provided that it is ensured at a
precipitation angle of approximately 45 degrees. Keep the artificial rain on
the aerial optical terminal box for 15 minutes. Evidence of water penetration
inside the aerial terminal box must be a failure.
Note: For checking the water penetration inside the terminal box, some
techniques may be used such as:
- Placement of special paper, at strategic points, for the water detection (eg.
WATESMO paper), or spread talcum powder inside the terminal box.
Procedure:
When subject to 28 temperature cycles of 6 hours each, with a re-entry every
7 cycles (where applicable).
- Conditioning:
High Temperature = +75°C;
Low temperature = -25°C.
- Recovery: 2 hours at 25°C.
- Attenuation must be measured at least every 10 minutes.
Note: After cycles # 7, 14 and 21, the terminal box must remain for 2 hours at
25° C and then the re-entry operation must be performed.
Procedure:
The polymeric material of optical terminal box must be subject to 10
continuous periods of 8 days with 1 day interval between periods in
weathering chamber.
Procedure:
The terminal box must be exposed for 168 hours at isoctane/toluene attack
(70/30).
6 - Purchase Unit The purchase unit of the Set of Optical Splicing Box (CEFO) is the product
unit.
8 - Quality Assurance Corning is SGI certified according to ISO 9001:2000 ABNT NBR, ABNT
NBR ISO14001: 2004 and OHSAS 18001:1999
Address: Estrada do Camorim, 633 CEP 22708 070 Rio de Janeiro RJ Brasil
July - 2014
Phone: 55 (21) 3416 5150 Fax. 55 (21) 24412037
Page 15 of 15