Sie sind auf Seite 1von 10

o P E R AT I N G A F O O D E S TA B L I S H M E N T I N nyc

佡 determining the extent of nec-


PART 2, essary hand contact by food
preparation workers during
Suggested Guide to Food the preparation and serving
stages;
Establishment Design 佡 ensuring that all food items
are maintained at proper time
and temperatures throughout
these processes until service.

INTRODUCTION
Keeping these specific needs in
mind as you read the various
sections of this guide will allow

T
he following guide to food establishment design is
you to design an equipment lay-
provided to assist you in selecting the proper equip- out that will meet your needs, as
ment to meet the needs of your business. An excellent well as the requirements of
applicable regulations.
way to begin a self-assessment of your needs is to first determine
the menu you plan to provide your customers, and then to uti- Food must be obtained from
approved sources that comply
lize this menu to list the specific steps in the food preparation
with all laws relating to food and
process for each menu item. food labeling. The use of food
This process generally includes: are to be stored prior to prepa- prepared in any place that is not
ration; operated under the jurisdiction
佡 defining whether specific food of an appropriate regulatory
items are potentially hazardous; 佡 reviewing how foods are to be
agency and that does not have a
prepared (e.g., cooked to order,
佡 determining how food items current permit or license to
as opposed to prepared in advance
are received into your facility; operate from that agency, if
of order), including an assess-
required, is prohibited.
佡 deciding the storage method ment of necessary cooking,
and length of time food items cooling, and holding methods;

16 NEW YORK CITY DEPAR TMENT OF HEALTH & MENTAL HYGIENE


o P E R AT I N G A F O O D E S TA B L I S H M E N T I N nyc
佡 Sealed to the floor around the
FOOD SERVICE EQUIPMENT entire perimeter of the equip-
ment (the sealing compound
quipment that complies with Between uses, food dispensing should be pliable but not
E the design and construction
standards of the National
utensils should be stored in the
food with the handle extended
gummy or sticky, non-shrink-
ing, retain elasticity and pro-
Sanitation Foundation (NSF) is out of the food, or clean and vide a water and vermin-tight
acceptable. The NSF Manual on dry, or in a dipper well with seal); or
Sanitation Aspects of Installation running water at an adequate 佡 Elevated on legs to provide at
of Food Service Equipment is an velocity and volume to cleanse least a 6 inch clearance
excellent reference. them during intervals between between the floor and equip-
intermittent use. ment; or
Adequate facilities must be
provided to promote good Equipment, including food 佡 Installed on a smooth, non-
hygienic practices, sanitary food preparation tables, ice makers absorbent, masonry base.
handling and to minimize the and ice storage equipment should Masonry bases and curbs may
potential of cross contamination not be located under exposed or be coved at the junction of the
between finished and raw prod- unprotected sewer lines, open platform and the floor to facil-
ucts. Provision of separate areas stairwells or other sources of itate easy cleaning and prevent
designed to segregate food han- contamination. insect harborage. Spaces
dling operations involving raw between the masonry base and
The following outlines some
and ready-to-eat products greatly the equipment should be
of the equipment installation
reduces the possibility of cross sealed.
requirements and recommen-
contamination. A separate food
dations to insure proper spac-
preparation sink, for washing Spacing between and behind
ing and sealing to allow for
raw fruits and vegetables, if these equipment should be sufficient
adequate and easy cleaning:
items are served, is suggested. to permit cleaning. The following
Where the use of portable chop- Whenever possible, equipment separations may prove adequate:
ping boards is planned, they may should be mounted on castors or
wheels to facilitate easy moving, 佡 When the distance to be
be colored, coded or labeled for
cleaning and provide a flexibility cleaned is less than 2 feet in
specific use.
of operation. Wheeled equipment depth, the width of the clear
All food on display, during unobstructed space should not
requiring utility services may be
service or while being held, be less than 6 inches;
provided with easily accessible
should be adequately protected
quick-disconnects or the utility 佡 When the distance to be
from contamination by the use
service lines may be flexible and cleaned is greater than 2 feet
of packaging, serving line, stor-
of sufficient length to permit but less than 4 feet in depth,
age or salad bar protector
movement of the equipment for the width of the clear unob-
devices, sneeze guards and dis-
cleaning. Local fire safety and structed space should be at
play cases, or by other effective
building codes should be checked least 8 inches;
and acceptable means.
to ensure that such installations
佡 When the distance to be
Where frozen desserts are do not present a conflict.
cleaned is greater than 4 feet
being portioned and dispensed,
but less than 6 feet in depth,
running water dipping wells Floor-Mounted Equipment
the width of the clear unob-
should be provided for the in- Floor-mounted equipment not
structed space should be at
use storage of dispensing uten- mounted on wheels or castors
least 12 inches;
sils, e.g. ice cream scoops. should be:

NEW YORK CITY DEPAR TMENT OF HEALTH & MENTAL HYGIENE 17


o P E R AT I N G A F O O D E S TA B L I S H M E N T I N nyc
佡 When the distance to be Table Mounted Equipment 140°F to 41°F within 4 hours is
cleaned is greater than 6 feet Table mounted equipment recommended.
in depth, the width of clear may be:
The capacity of the rapid cool-
un- obstructed space should
佡 Sealed to the table or counter; ing units should be sufficient to
be at least 18 inches.
or accommodate the volume of food
If the equipment butts against required to be cooled to 41°F
佡 Elevated on legs to provide at
a wall it should be joined to the within 4 hours.
least a 4 inch clearance
wall and sealed in a manner to
between the table or counter Point-of-use refrigerators
prevent liquid waste, dust and
and equipment, and installed should be provided at work sta-
debris from collecting between
to facilitate cleaning; or tions for operations requiring
the wall and the equipment.
preparation and handling of
佡 Easily movable.
When equipment is butted potentially hazardous foods which
together or spreader plates are used, would otherwise be kept unre-
the resultant joint should be effected Hot-Holding and Reheating frigerated for 2 or more hours.
in a manner to prevent the accu- Equipment Refrigeration units, unless designed
mulation of spillage and debris Hot holding equipment must for such use, should not be located
therein and to facilitate cleaning. be capable of maintaining the directly adjacent to cooking
internal temperature of potential- equipment or other high heat
Unobstructed aisles and work- ly hazardous foods at 140°F or producing equipment which may
ing spaces should be provided of above during service, display or tax the cooling system’s operation.
sufficient width to permit holding periods.
employees to perform their duties
readily without contamination Reheating equipment must be Additional Recommendations
of food or food-contact surfaces capable of raising the internal for Refrigerated Storage Units
by clothing or personal contact. temperature of potentially haz- All walk-in units may be con-
ardous foods to at least 165°F structed and installed in accordance
All utility and service lines and within 2 hours. with NSF standards, the NSF
openings through the floor
Metal stem-type, numerically Manual on Sanitation Aspects of
should be sealed adequately.
scaled, indicating thermometers Installation of Food Service
Exposed vertical and horizontal
accurate to + or –2°F are required Equipment and the NSF refer-
pipes and lines are best kept to a
to monitor temperatures. ence guide, entitled “Sanitation
minimum. The installation of
Aspects of Food Service facility
exposed horizontal utility lines
Plan Preparation and Review.”
and pipes on the floor is not rec- Refrigeration Equipment, Sizing
ommended. Any insulation and Design 佡 Shelving for walk-ins that are
materials used on utility pipes or Refrigeration facilities should approved by NSF for use
lines in the food preparation or be adequate to provide for the under standard #7 (for refrig-
dishwashing areas must be proper storage, transportation, eration use) is acceptable. In
smooth, non-absorbent and easy display, service and rapid cooling units used to rapidly cool
to clean. Switch boxes, electrical of potentially hazardous foods. potentially hazardous foods, the
control panels, wall mounted Specific refrigeration needs should recommended vertical space
cabinets, etc., when installed in be based upon the menu, num- between shelves is a minimum
areas subject to splash from nec- ber of meals, frequency of deliv- of 6 inches.
essary cleaning operations, food ery, and time of preparation in 佡 Interior finishes approved by
preparation, or utensil or equip- advance of service, a rapid cool- NSF for use in walk-in and
ment washing, should be water- ing device capable of cooling reach-in refrigeration units
tight and washable. potentially hazardous foods from would be acceptable except for

18 NEW YORK CITY DEPAR TMENT OF HEALTH & MENTAL HYGIENE


o P E R AT I N G A F O O D E S TA B L I S H M E N T I N nyc
galvanized metal which is not 佡 If the walk-in floors are water- 佡 Walk-in units should contain
recommended because of its flushed for cleaning, or receive candescent vapor-proof lamps
tendency to rust. the discharge of liquid waste or providing a minimum 20 ft.
excessive water from melted ice, candles of light.
佡 All refrigeration units should the floors should be quarry tile
佡 Walk-in units should have
have numerically scaled ther- or its equivalent with silicone
condensate waste draining into
mometers accurate to + or or epoxy impregnated grout,
the sewage system via an air
–2°F with the temperatures have an integrally coved base,
break located outside the unit.
sensing unit located to mea- and be sloped to a suitably
sure air temperature in the trapped floor drain.
warmest part of the unit.

Each hand washing sink compartments should be provid-


HYGIENE should be provided with hot and ed. A two compartment sink
cold running water preferably may find application in the
Hand Washing Facilities tempered by means of a mixing washing and sanitizing of bar
Provide a separate hand wash- valve or a combination faucet. It glassware. In these cases an elec-
ing sink, dispensed hand soap, is recommended that any self- trical brush device should be used
hand drying device or disposable closing or metering faucet should in conjunction with a combination
towels, and waste receptacle for be designed to provide a flow of detergent-sanitizer in the sink
each food preparation area, water for at least 15 seconds without compartment used for washing
utensil washing area and toilet the need to reactivate the faucet. utensils. The sink compartments
room. The use of a common must be large enough to accommo-

;;;;;
sink for food preparation or for Ware Washing date the largest piece of equipment
washing equipment and/or uten- Manual Facilities or utensil to be cleaned and each
sils as well for hand washing is For manual washing and sani- compartment should be supplied
not a recommended practice. tizing of utensils, a stainless steel with adequate hot and cold
sink with no fewer than three potable running water.

PRE-RINSE
Approved Method for Hand-Washing Dishes and Utensils DRAIN

SCRAPE WASH RINSE SANITIZE

Drain and Air Dry. Do


not towel dry. Toweling
re-contaminiates uten-
Scrape and sils. Store utensils,
Pre-Rinse with
Sanitize utensils in third glasses and cups
warm water
from a spray Wash in first com- compartment by use of (inverted) in a clean
type nozzle all partment with warm hot water or a chemical dry place.
dishes and water at 110°–120°F Rinse utensils in second sanitizer. Rinse utensils
utensils using a good wash- compartment by immer- making use of a long-handled wire basket, in
promptly sion in clean, warm clean hot water at a temperature of at least 170°
ing compound, brush
before food water. Washing com- for no less than 1/2 minute. Auxiliary heat is nec-
can dry on them. This step keeps and “elbow grease.”
Washing compound pound is rinsed off. essary. An alternate method is utensil immersion
the wash water free of large food
does not sanitize Change the rinse water for a least one minute in a sanitizing solution
particles; loosens dried-on foods;
reduces stains on dishes; saves utensils. frequently. Do not rinse containing at least 50 ppm available chlorine at a
detergent. dishes in dirty water. temperature of at least 75°

NEW YORK CITY DEPAR TMENT OF HEALTH & MENTAL HYGIENE 19


o P E R AT I N G A F O O D E S TA B L I S H M E N T I N nyc
In the case of equipment too A floor drain is recommended Hot water for mechanical
large to be sanitized by immer- in the immediate vicinity of the dishwashers should be
sion, but in which steam can be washing area and any area where 140°F–165°F for washing and
confined, treatment with culi- wet pots, utensils and equipment 180°F for sanitizing.
nary quality steam is acceptable are air drying.
The water temperature for
to achieve sanitization. The
Thermometers and appropri- manual hot water sanitization
swabbing of fixed equipment
ate chemical test kits should be should be at least 170°F.
with a solution of at least twice the
available and used to monitor
concentration required for that Toilet Facilities
water temperatures and chemical
sanitizing solution when used for Toilet facilities should be installed
concentrations.
immersion is also acceptable. according to local plumbing
Drying Facilities ordinances. They should be con-
Mechanical Facilities veniently located and should be
Adequate facilities must be
A commercial dishwashing accessible to employees and/or
provided to air dry washed uten-
machine approved by NSF under patrons at all times.
sils and equipment.
Standard #3 should be provided.
The installation and required Adequately sized drain boards, All food service establishments
appurtenances should be in con- or easily moveable dish tables, with a seating capacity of 20 or
formance with NSF Standard fabricated in conformance with more except those in operation
#34, the NSF Manual on NSF standards and separate for on or before December 5, 1977
Sanitation Aspects of installation soiled and cleaned utensils must provide appropriately iden-
of Food Service Equipment, and should be provided. tified and maintained toilet facil-
applicable code requirements. ities for their patrons. Suitable
The drain boards and dish public notice of any such alter-
Among the specific require- tables should be pitched a mini- nate facility must be conspicu-
ments for installation of machines mum of 1/8 inch per foot and ously posted within the food
that use chemicals to achieve drainage directed into a sink so establishment.
sanitization are the following: as to prevent contamination of
other areas of the dish table or Employee toilet facilities may
佡 The chemical sanitizing feeder be used by patrons only if they
drain board. Drain boards may
should be approved for use with do not pass through a food
generally be at least 36 inches to
the specific make and model preparation or utensil washing
48 inches long and 30 inches wide.
of the machine in question. area to access them and there are
佡 A visual flow indicator is sug- Determining Hot Water Supply separate facilities for each sex.
gested to facilitate monitoring Requirements
Toilet rooms should be com-
of the operation of the sanitiz- The hot water supply should
pletely enclosed and have tight
ing agent feeder. Other indi- be sufficient to satisfy the con-
fitting, self-closing, solid doors.
cating devices such as audible tinuous and peak hot water
They should be vented to the
alarms may also be used. The demands of the establishment.
outside by an operable, screened
flow indicating devices should For purposes of estimating the
window or mechanical device.
be installed so as to be easily hot water generating capability,
Fixtures should be designed to
viewed by the operator. assume a supply temperature
be easily cleanable.
requirement of 115°F to each
General fixture and 180°F to mechanical
Adequate facilities should be dishwashing machines.
provided for pre-flushing or pre-
Hot water for hand washing
scraping equipment and utensils.
should not exceed 115°F.

20 NEW YORK CITY DEPAR TMENT OF HEALTH & MENTAL HYGIENE


o P E R AT I N G A F O O D E S TA B L I S H M E N T I N nyc
wall and floor covering and ing Instal-lation of Walk-in
SURFACE FINISHES provide at least 1/4 inch radius. Refrigerators and Storage
Freezers.”
佡 Properly installed, trapped
Finish Schedule
floor drains should be provided
Walls
The table on the following page in floors that are water flushed
佡 The walls—including non-sup-
provides some acceptable finishes for cleaning or that receive dis-
port partitions, wall coverings
for floors, walls and ceiling, by area. charges of water or other fluid
and ceilings of walk-in refriger-
waste from equipment or in areas
Floors ating units, food preparation
where pressure spray methods
areas, equipment washing and
佡 All floor coverings in food for cleaning equipment are used.
utensil-washing areas, toilet
preparation, food storage, Floors should be sloped to
rooms and vestibules—should
utensil-washing areas and drain at least 1/8 inch per foot.
be light-colored, smooth, non-
walk-in refrigeration units,
佡 Grouting should be non- absorbent and easily cleanable.
dressing rooms, toilet rooms
absorbent and may be impreg- Studs, joists and rafters should
and vestibules must be smooth,
nated with epoxy, silicone or not be exposed in walk-in
non-absorbent, easily cleanable
polyurethane. refrigerating units, food prepa-
and durable. Approved anti-
ration areas, equipment-wash-
slip floor covering may be used 佡 All walk-in refrigeration units,
ing areas, toilet rooms and
in high traffic areas only. both with prefabricated floors
vestibules. Where permitted
and without, should be
佡 Coving at base junctures they must be finished to pro-
installed according to the NSF
should be compatible to both vide an easily cleanable surface.
“Special Consideration regard-

Acceptable Finishes
AREA FLOOR WALL CEILING
Kitchen Quarry tile; poured Stainless steel, Fiberboard plastic coated,
seamless concrete aluminum, FRP Board, metal clad, drywall with epoxy
tile with approved grout surface, plastic laminated panels

Food Prep and Same as above, plus Same as above Same as above
Ware-washing approved wall panels,
drywall taped epoxy,
blocked filled and epoxy paint
glazed surface

Dry storage Same as above, plus Same as above Same as above


sealed concrete,
commercial grade
vinyl tiles

Serving Same as above Same as above Same as above

Toilet Room Quarry tile, poured Same as above Same as above


seamless concrete

Janitor Closet Quarry tile, poured Same as above Same as above


seamless concrete

Walk-ins Quarry tile, Aluminum, Aluminum,


aluminum, stainless steel, tile stainless steel
stainless steel with approved grout

NEW YORK CITY DEPAR TMENT OF HEALTH & MENTAL HYGIENE 21


o P E R AT I N G A F O O D E S TA B L I S H M E N T I N nyc
佡 Glazed surfaces could be of approved block filler followed Ceilings
glazed block, brick or ceramic by the application of an epoxy- 佡 Finishes should be light-col-
tile. If these surfaces are to be type covering. All mortar joints ored, smooth, non-absorbent
used, they should be applied should be only slightly tooled and easily cleanable. Acoustical
with epoxy, silicone or a poly- and suitably finished to render material free of porous perfo-
urethane grouting. Concrete them easily cleanable. rations, smooth and durable
block, if used, should be ren- enough to be washed with a
佡 Plastic laminated panels may
dered non-porous and smooth cloth or sponge may be used,
find applications. Joint finishes
by the application of an provided ventilation is ade-
should be compatible with the
approved block, if used, should quate to minimize soiling.
wall structure. Voids should be
be rendered non-porous and
eliminated at joints.
smooth by the application of an

22 NEW YORK CITY DEPAR TMENT OF HEALTH & MENTAL HYGIENE


water supply inlet and the fixture’s Fixtures and equipment
PLUMBING CONNECTIONS flood-level rim. requiring indirect waste connec-
Fixtures and equipment tions include:
requiring back siphonage protec-
Plumbing and Cross Connections Food preparation and
Plumbing must be sized and tion include:
ware-washing sinks;
installed according to applicable Dipper wells Hose connections Refrigerators and freezers;
codes. There should be no cross Sinks Dishwashers Ice makers and storage bins;
connection between the potable Steam tables Ice machines
water supply and any non- Water closets Urinals Steam tables and kettles;
potable or questionable water Potato peelers Garbage grinders Dipper wells.
supply. Where non-potable
water systems are permitted for Drains–Indirect Waste
purposes such as air condition- There should be no direct
ing and fire protection, the non- connection between the sewage Flood Level Rim
potable water must not contact system and any drains originat-
food, potable water or equip- ing from equipment in which
ment that contacts food or uten- food or food utensils are placed.
sils directly or indirectly. The An unobstructed vertical air
piping of any non-potable water space between the lowest open- Air Gap
system should be clearly identi- ing of the fixture drain and the
fied so that it is readily distin- flood-level rim of the receiving
guishable from piping that car- receptacle or drain opening must
ries potable water. be provided. The air break for
the indirect waste shall be pro- A grease interceptor should be
Submerged Inlet Protection vided by terminating the open installed in the waste line lead-
The potable water system end of the pipe at least 1 inch ing from pot sinks, floor drains
must be installed to preclude the above the flood rim level of the receiving waste from soup or
possibility of back-flow. Devices receiving fixture or receptacle. stock kettles, food scrap sinks,
should be installed and main- Unidirectional check valves or scullery sinks and the scraper
tained to protect against back- equivalent devices are not accept- section of commercial dishwash-
flow and back siphonage at all able for this purpose. ers to prevent grease from enter-
fixtures and equipment unless an ing the drainage system.
Indirect sewer connections
air gap is provided.
should be located within 2 feet Interceptors should remove an
The air gap, when used, must of the equipment which it is average of at least 90% of the
be at least twice the diameter of intended to protect and on the grease or other extractable mat-
the water supply inlet, but not less inlet side of the grease intercep- ter in the waste water and
than 1 inch, and exist between the tor and “p” trap. should conform to the require-
ments of the New York City
Department of Environmental
Protection, Industrial Waste
Control Section.

Indirect Waste Connections Open Waste

NEW YORK CITY DEPAR TMENT OF HEALTH & MENTAL HYGIENE 23


o P E R AT I N G A F O O D E S TA B L I S H M E N T I N nyc
20 foot candles at 30 inches be designed, constructed and
OTHER CONSIDERATIONS from the floor. installed in conformance with the
Shielding such as plastic National Fire Protection
shields, plastic sleeves with end Association Bulletin #96.
caps, shatterproof bulbs and/or
Insect and Rodent Control  NOTE: The installation and
other approved devices should be
Openings to the outside operation of ventilation sys-
provided for all artificial lighting
should be effectively protected tems is regulated by the
fixtures located over, by, or within
against the entrance of rodents. NYC Department of
food storage, preparation, service
Outside openings should be pro- Buildings, the NYC Fire
and display facilities. Sheilding
tected against the entrance of Department and the NYC
should also be provided where
insects by the installation of tight- Department of Environmental
utensils and equipment are cleaned
fitting self-closing doors, win- Protection. For additional
and stored, particularly where
dows, self-closing serving win- information regarding these
they may be exposed to extremes
dows at drive-throughs, screen- installations and other require-
in temperature variation.
ing, controlled air currents, ments, including ventilation
vestibules or by other means. Heat lamps, where used, should hoods, ducts and fire sup-
be protected against breakage by pression systems (ANSUL),
Screen doors should be self-
a shield surrounding and extending you should contact these
closing and screens for windows,
beyond the bulb, leaving only agencies.
doors, sky-lights, transoms,
the face of the bulb exposed.
intake and exhaust air ducts and
Cooking equipment ventila-
other openings to the outside
tion hoods and devices should be
should be tight-fitting and free Ventilation
designed and installed to prevent
of breaks. Screening material All establishments shall be
grease or condensation from col-
should not be less than sixteen adequately ventilated to prevent
lecting on walls, ceilings, and
mesh to the inch. excessive heat, steam, condensa-
fire suppression supply piping,
tion, vapors, odors, smoke and
Loading docks and delivery and from dripping onto food or
fumes. Ventilation to the outside
doors should be provided with food contact surfaces.
air must comply with applicable
effective air curtains or vestibules
law and regulation and must not Make-up air intakes should be
with self-closing doors to pre-
create a nuisance or unlawful screened (bird screen) and fil-
clude the entrance of insects.
emission. Intake and exhaust ducts tered to prevent the entrance of
Any opening between the floor must be constructed and main- dust, dirt, insects and other con-
and bottom of outer doors tained to prevent dust, dirt or taminating material. Where the
should be protected with rodent- other contaminants from enter- introduction of make-up air will
proof material. ing the establishment. Mechanical cause condensation, drafting or
ventilation must be installed in interfere with the exhaust or
Lighting rooms where odors, vapors or vapor capture efficiency of the
Permanently fixed artificial fumes originate. Ventilation hoods hood, the make-up air should be
light sources should be installed and devices must be constructed tempered. A tempered make-up
to provide at least 30 foot can- and installed to prevent grease or air system may be required if the
dles of light on all food prepara- condensation from collecting on exhaust is greater than 1,500 cfm.
tion surfaces and at equipment walls or ceilings and from drip-
The installation of fire sup-
or utensil-washing work levels. ping into food or onto food-
pression system supply piping in
All other areas, including dining contact surfaces.
the unfiltered air space in
areas during cleaning operations,
All hoods should meet NSF exhaust hoods should be limited
should be provided with at least
Standard #2 requirements and to vertical runs to minimize

24 NEW YORK CITY DEPAR TMENT OF HEALTH & MENTAL HYGIENE


o P E R AT I N G A F O O D E S TA B L I S H M E N T I N nyc
grease collection. Exposed piping Shelving may be constructed Insecticides and rodenticides
must be cleanable. of suitably finished wood but should be kept in their original
Hot water sanitizing dishwash- preferably of non-corrosive containers.
ing machines should be provided metal or plastic. Approved food
with adequate ventilation that is containers with tight fitting cov- Dressing Room and Lockers
sized according to the manufac- ers and scoops should be used Rooms or areas separate from
turer’s specifications. for storing and dispensing bulk food preparation, storage or ser-
items or broken lots. Food con- vice areas, and separate from
tainers should not be stored under utensil washing or storage areas,
Utility Facility exposed or unprotected sewer should be provided if employees
At least one utility sink or lines. Items should be spaced routinely change clothes within
curbed cleaning facility with a from walls sufficiently and raised the establishment.
floor drain should be provided at least 6 inches above the floor to
Lockers or other suitable stor-
for cleaning mops and for the allow for adequate maintenance
age facilities should be located in
disposal of mop water or similar and inspection of the facility.
dressing areas for employees to
liquid wastes.
Storage facilities should be store their personal belongings.
provided to store cleaned and
sanitized utensils and equipment Garbage Storage
Storage
at adequate heights above the Garbage and waste grease
The dry storage space required
floor protected from splash, should be placed in durable, eas-
depends upon the menu, number
dust, overhead plumbing or ily cleanable, watertight, nonab-
of meals, quantities purchased
other contamination, on fixed sorbent, rodent- and insect-
and frequency of delivery. Store-
shelves or in enclosed cabinets. proof containers with tight fit-
rooms should be located adja-
ting lids. An area for storage of
cent to food preparation areas Poisonous and toxic materials
these containers and facilities for
and convenient to receiving. should be stored in areas desig-
their cleaning should also be pro-
Ideally, the storeroom should be nated for such use and for no
vided.
free of un-insulated steam and water other purpose, or in a storage
pipes, water heaters, transformers, area outside the food, equipment
refrigeration condensing units, and utensil storage area.
steam generators or other heat Bactericides and cleaning com-
producing equipment. The area pounds should never be stored
should be well ventilated and with insecticides, rodenticides,
maintained at 50°F to 70°F. or other poisonous materials.

NEW YORK CITY DEPAR TMENT OF HEALTH & MENTAL HYGIENE 25