Beruflich Dokumente
Kultur Dokumente
+ +
EN 60601-1 Bauar t gepruft
IEC 60601-1 Sicherheit
egel ma ge
od o s
be wac g
www. tuv.com
8 ID 2000000000
■ Features ■ Applications
Medical (2x MOPP) ITE safety approvals Medical equipment
Suitable for BF application with appropriate system Diagnostic or biological facilities
consideration (Touch current < 100uA/264VAC) MRI, CT and PET scanners
1U low profile Test or measurement systems
Universal AC input / Full range Telecommunication equipment
Output voltage and current programmable Factory automation and aging equipment
Built-in parallel function / output programmable / global Laser equipment
enable / remote local ON-OFF / auxiliary DC output /
over temperature alarm / DC OK
Cooling by thermostatically controlled fan with fan alarm
function
Protections: Short circuit / Overload / Over voltage /
Over temperature for all output modules
5 years warranty
■ Description
NMP family is a 1U low profile modular and configurable type power supply from MEAN WELL. This family
comprises two power wattage for the line-up, 650W and 1200W, and the output modules deliver up to 240W
with adjustable options for the major working voltages used in the industries 5V, 12V, 24V, 48V. NMP family
complies with safety approval, the medical (2x MOPP between primary to secondary) and ITE standards.
Offering the best flexibility for various types of applications.
BLOCK DIAGRAM
NMP1K2 & NMP650 PFC fosc : 85KHz(NMP1K2)
70KHz(NMP650)
PWM fosc : 100KHz
ALARM
CONTROL T-ALARM
RECTIFIERS REMOTE
CONTROL ON/OFF ON/OFF
FAN
NMS-240
PWM fosc : 175KHz
+S
POWER RECTIFIERS POWER +V
SWITCHING & FILTER SWITCHING -V
-S
O.L.P
DETECTION DC OK & LED
O.V.P PV
CIRCUIT
PC
PWM
O.C.P
CONTROL
O.T.P
RECTIFIERS REMOTE
CONTROL
ON/OFF ON/OFF
CURRENT
SHARE CS
RECTIFIERS
& AUX POWER
FILTER (5V/10mA)
100
100 230VAC
90
CONTUINUOUS
80 80
115VAC 70
60
LOAD (%)
50
LOAD (%)
60
40
50
20 40
MECHANICAL SPECIFICATION
※ NMP1K2 Case No.260 Unit:mm
250
14 max. 219.1 6.1 10 max.
+V
11 8.6
20.5
41
4-M4(Both Sides) L=4 -V
2 2
122 92
CN32
14.8
6 2
23.5
5 1
20
4-M4 L=4
1 1
20
Air flow
direction
127
80
20
20
1
9.5
20
2 TB1
3
12.2
8
1 1
Mounting Screw
※AC Input Terminal Pin No. Assignment
L
Pin No. Assignment Diagram Maximum mounting torque
1 FG
2 AC/N 12Kgf-cm
3 AC/L
MECHANICAL SPECIFICATION
※ NMP650 Case No.259 Unit:mm
250
14 max. 219.1 6.1 10 max.
+V
11 8.6
20.5
41
4-M4(Both Sides) L=4 -V
2 2
122 92
CN32
16.8
6 2
23.5
5 1
20
Air flow 4-M4 L=4
direction
1 1
89
42
20
1
9.5
20
2 TB1
3
8
12.2
1 1
Chassis of NMP
(thickness 1.6mm)
※ Mounting Instruction Mounting Surface
Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque
1 M4 4mm 7~10Kgf-cm
2 M4 4mm 7~10Kgf-cm
Mounting Screw
L
MECHANICAL SPECIFICATION
※ NMS-240 Output Module
20 118.5
LED
CN81
1 3 5 7 9
4.8
10.5
2 4 6 8 10
17.5
VR60
37.9
-V
11
+V
※ Blank slot
Blank slot should be assembled with BLANK-NMS240, Please contact MEAN WELL for details.
Function Manual
1. “Global ON/FF Control” function is not used
※ The power supply unit will have no output if the shorting connector ( accessory comes along with the PSU ) is not assembled . It contains one shorting
wire : it is from RC1 (CN32 - PIN6) to GND-P (CN32 - PIN3)
CN32
CN32 NMP1K2 CN32 NMP650
+5V +5V
2 1
2 -AUX-P -AUX-P 1 2 1
GND-P
TB1 (CN32 - PIN3) TB1
6 5 GND-P GND-P 6 5
RC1 T-Alarm
N L 6 5 N L
RC1
(CN32 - PIN6) (Shorting connector)
CN32
CN32 NMP1K2 CN32 NMP650
+5V +5V
2 -AUX-P -AUX-P 1
2 1 GND-P 2 1
TB1 (CN32 - PIN3) TB1
6 5 GND-P GND-P 6 5
RC1 T-Alarm
N L 6 5 N L
RC1
(CN32 - PIN6) SW
◎ Local ON/OFF
The NMS-240 can be turned ON/OFF by using the ‘‘local ON/OFF’’ function.
Between RC2 (CN81-PIN3) and GND (CN81-PIN1 or 2) Output Modules Status (NMS-240)
SW OFF (open) ON
SW ON (short) OFF
NMS-240
CN81 CN81
LED 13579
1 9 2 4 6 810
LOAD
GND SW RC2
+V
+
( PIN1 or 2) ( PIN3)
3.Remote Sense
※ The Remote Sense compensates voltage drop on the load wiring up to 0.5V.
CN81
13579
CN81 LED 2 4 6 810
GND VCC2 CS PV -S - -S
-V ( PIN10)
2 10
LOAD
+V +S
+
( PIN9)
Vout
NMS-240
120
OUTPUT VOLTAGE (%)
CN81
CN81 LED 100
13579
2 4 6 8 10
1 9 80 Non-Linear
GND RC2 DC_OK PC +S VR60 60
50
GND VCC2 CS PV -S 40
-
-V 12V only
2 10 20 (E code)
PV LOAD
GND EXTERNAL ( PIN8) PV (Referenced to GND)
( PIN1 or 2) VOLTAGE (DC) +V 1 2 2.5 3 4 5 6
+
NMS-240 Iout
20
LOAD
GND PC
EXTERNAL ( PIN7) +V PC (Referenced to GND)
( PIN1 or 2)
+
6.Auxiliary Power
※ +5V-Aux_P: Aux. power is 5V/2A (NMP1K2).
Aux. power is 5V/1.5A (NMP650).
+5V-AUX-P
(CN32 - PIN1 & 2) CN32
RC1
(CN32 - PIN6)
NMS-240
CN81
CN81 LED 13579
2 4 6 8 10
1 9
7. DC OK Signal
“DC OK” signal is a TTL level signal. It indicates the output status of the output modules. “High” when module turns on.
The maximum sourcing current is 10mA (4.5~5.5V).
NMS-240
CN81 CN81
LED 13579
1 9 2 4 6 8 10
GND LOAD
DC_OK
( PIN1 or 2)
( PIN5) +V
+
8. T-Alarm Signal
TTL signal output for over temperature alarm. The maximum sourcing current is 10mA.
Between T-Alarm (CN32 PIN 5) and GND-P (CN32 PIN 3 or 4) Internal temperature (U702) Output Status
0~0.5V The internal temperature is normal. ON
4.5~5.5V Exceeds the limit of temperature alarm. ON
4.5~5.5V Exceeds the “safe limit” of temperature alarm. OFF
CN32
RC1 T-Alarm
N L 6 5 N L
RC1 T-Alarm
(CN32 - PIN6) (CN32 - PIN5)
NMS - 240 NMS - 240 NMS - 240 NMS - 240 NMS - 240 NMS - 240
-V +V -V +V -V +V -V +V -V +V -V +V
GND (PIN1 or 2)
CS (PIN6)
GND (PIN1 or 2)
CS (PIN6)
9 +S -S 10 9 +S -S 10 9 +S -S 10 9 +S -S 10 9 +S -S 10 9 +S -S 10
PC PV PC PV PC PV PC PV PC PV PC PV
RC2 VCC2 RC2 VCC2 RC2 VCC2 RC2 VCC2 RC2 VCC2 RC2 VCC2
GND GND GND GND GND GND GND GND GND GND GND GND
1 2 1 2 1 2 1 2 1 2 1 2