Optimize Your
Flow Processes
GO THINK
GREEN… BLUE
®
Think Magnetrol .
TABLE OF CONTENTS
Make Success With Centrifugal Blowers a Breeze 7
Consider a variety of factors to achieve efficient and reliable operation
Additional Resources 22
PRODUCT FOCUS
The bronze ball valves are full port and designed for po-
table water applications. The ball valves are available in
1/2 - and 3/4-in. press sizes and 3/4-in. hose sizes. Other fea-
tures include a lockable metal handle, stainless steel ball
and EPDM sealing element.
°F
fact
°Brix
t/h
lb/h
AD INDEX
Magnetrol • www.magnetrol.com������������������������������������������������������������������������������������������������������������� 2
Krohne • http://us.krohne.com������������������������������������������������������������������������������������������������������������������4
Flexim • www.flexim.com����������������������������������������������������������������������������������������������������������������������������6
PRODUCT FOCUS
The ISO 5211 mounting pads are designed for direct mounting
of Triac rack and pinion pneumatic and electric actuation sys-
tems. Substantial inventories and capable, technical distributors
throughout North America can help meet the tough, demanding
requirements of chemical facilities, says the company.
PIOX S ®
www.piox-s.com
www.flexim.com
Contact us for a free trial measurement!
www.chemicalprocessing.com
D
iverse applications rely on blow- variation are both important features of a
ers to supply gas at relatively low centrifugal blower. Speed variation usu-
pressure. Process plants usually ally serves as the fundamental means of
opt for centrifugal blowers; they use rotat- capacity and head control. In many cases, a
ing impellers to increase the speed of gas system of variable inlet guide vanes (VIGVs)
streams. These blowers most often have a also is installed as another way to regulate
single sophisticated three-dimensional im- the blower operation to give the required
peller — but special blowers sometimes use operational flexibility. Using both methods,
two or three impellers. a blower can provide a minimum flow as
low as 20–30% of the normal flow rate.
Centrifugal blowers often have variable
frequency drives (VFDs) to optimize effi- DESIGN AND OPERATION
ciency as operating conditions change, pro- Overhung designs are popular for centrifu-
vide overcurrent protection, reduce power gal blowers. In some designs that use a
consumption, and facilitate soft startup and gear unit, the impeller is mounted on the
shutdown. The most important aspect of gear unit flange. An overhung design of-
VFDs is preventing surge over a wide oper- fers many benefits such as simplicity and
ating range. easy access for servicing the diffusor vane
assembly or other parts while the casing is
Capacity turndown and delivered head off. For safety reasons, a vent valve allows
CENTRIFUGAL BLOWERS
the volute to be purged with inert gas prior installed as a standby rather than kept in a
to startup. warehouse. Sometimes, installing a redun-
dant blower is wise (Figure 1). Standby units
The impeller usually is three-dimensional require regular monitoring to ensure they
semi-open (unshrouded) design. Its vanes will work when needed.
typically are machined out of a solid forg-
ing. Material options include aluminum Balancing and spin testing are important for
alloys, stainless steel and alloy steels — and impeller assemblies of high-speed blowers.
even titanium alloys for some special appli- Each element of the rotating assembly, i.e.,
cations. The impeller is fixed to the shaft by impeller, shaft, high-speed gear, etc., should
different methods — a popular one is a cy- be dynamically balanced to close toleranc-
lindrical polygon fit, with its unique torque es. The complete rotating assembly once
transmission capability. A key-less option assembled then should undergo dynamic
generally is preferred. balancing before installation. Finally, during
the mechanical test of the complete unit in
Spare parts and redundancy are important the shop, vibration probes should verify lack
for critical components such as lubrication of vibrations due to unbalance.
oil pumps, oil filters, oil coolers, etc. Stor-
ing individual parts of a component in a For many high-speed blowers (say, above
warehouse is fine but an entire unit, such 9,000 rpm), balancing the whole high-
as a spare lubrication oil pump, should be speed rotor assembly to ISO 1940 Grade G1
is a buffered labyrinth seal; it often is used vapor to large storage facilities while they
for air or non-process blower applications. are being unloaded. The gas or vapor fills
A common option for process blowers is a the void being created by the leaving liquid,
buffered carbon-ring seal (most often with thereby preventing tank collapse or the
nitrogen as the buffer gas). Depending on introduction of air/oxygen into the system.
application, a backup seal (usually an addi- These services require a customized blower
tional labyrinth seal) may be provided. that can handle a wide variety of operating
conditions at relatively low pressure ratios
A combined carbon-ring and labyrinth seal (say, pressure ratios around or below 2).
is a good choice for blowers. It consists As rough indication, typical volumetric flow
of a dual carbon-ring seal for normal use rates could be 1,000–40,000 m3/h, and
together with backup labyrinth seals; this pressure deltas around 0.5–1.5 bar. Many
limits the consumption of seal gas (usually designs use gear units. However, some
nitrogen) in case of damaged or worn-out modern blowers feature high-speed motors
carbon rings. This novel technology com- that eliminate the need for a gearbox and
bines lowest possible seal-gas consump- maximize efficiency and reliability.
tion with good reliability due to the backup
characteristic. The seal gas is injected into ANTI-SURGE VALVES
an intermediate chamber between the two The surge phenomenon in blowers (and
carbon rings and flows both ways from the compressors) can be understood as a com-
injection point. A slight process gas stream plete breakdown and reversal of the flow
leaks from impeller tip through the rear through the machinery. Every centrifugal
impeller labyrinth into the first chamber blower (or compressor) has its own operat-
behind the impeller where it mixes with one ing characteristic map and surge limits.
portion of the injected seal gas. This cham-
ber is vented to the blower suction, and as A centrifugal blower should have a fully en-
such, relieves the area behind the impeller gineered anti-surge system to prevent the
to near suction pressure. Due to the very machine from going into surge at startup,
small clearance between the carbon-ring shutdown and during low-flow operation.
seal and the shaft sleeve, the amount of seal This, as a minimum, should comprise a
gas is about 5 to 6 times smaller than that blower discharge-to-suction bypass loop in-
with a conventional labyrinth seal. corporating an anti-surge-valve actuated by
a suitable control system. Review anti-surge
RETURN GAS BLOWERS system details with great care.
One well-known application for blowers
is to return boil-off gas, generated gas or Anti-surge-valve sizing and system design
should follow modern engineering practices important. After all, eliminating the poten-
and well-established rules. For example, tial for surge and damaging vibration in the
some commonly used guidelines suggest blower system normally is a bigger concern.
keeping the anti-surge-valve flow coeffi- Properly addressing this requires attention
cient, Cv, within the range of around 1.8–2 to other parameters — noise, trim details,
times the required Cv based on the blower actuation system specifics, and many more.
surge flow on the highest blower speed
curve (on the blower map). For some spe- Coupling the latest technologies in anti-
cific cases, though, the anti-surge-valve Cv surge-valve and actuator designs with
might be as low as 1.75 times the required smart positioner technology and good ac-
Cv; don’t go lower than this. Also, ensure the cessory selection usually is key to achieving
anti-surge piping line is as close as possible optimal performance from an anti-surge
to the blower, and minimize pressure loss in system.
the anti-surge loop.
AN EXAMPLE
Having an appropriate Cv and meeting Let’s consider the selection of a centrifugal
valve-size and stroking-speed requirements blower for a critical process service with a
is only the first part of anti-surge-valve maximum flow rate of around 28,000 m3/h.
selection. Ensuring the anti-surge valve can Five operating cases with different flow
perform well in closed-loop control also is rates and pressures have been identified
RELATED CONTENT ON
CHEMICALPROCESSING.COM
“Take Advantage of Liquid-Ring Compressors,” http://goo.gl/XYWSxX
“Consider Gas Engines,” http://goo.gl/6OFuI5
“Pick the Proper Valve,” http://goo.gl/VmiYGT
“Master Metering Pumps,” http://goo.gl/bWJCqV
“Get Up to Speed on Gear Pumps,” http://goo.gl/ccL4tk
“Mind Piping System Mechanics,” http://goo.gl/Ni3pmw
“Count on Steam Turbines,” http://goo.gl/3pG7Nl
“Make the Most of Centrifugal Pumps,” http://goo.gl/izrF4B
“Investigate Integrally Geared Compressors,” http://goo.gl/VOk5F0
“Get Up to Speed on Axial Compressors,” http://goo.gl/jYQbrP
“How Much Will Your Compressor Installation Cost?,” http://goo.gl/KKTSKp
“Head Off Hassles During Startup,” http://goo.gl/6haqKk
“Apply Wet Screw Compressors Wisely,” http://goo.gl/X2rf4R
“Select the Right Centrifugal Compressor,” http://goo.gl/cmpIim
“Take Advantage of Gas Turbines,” http://goo.gl/a4ViHp
“Keep Out of Hot Water,” http://goo.gl/lxJKWy
“Choose the Correct Turbo-Compressor,” http://goo.gl/2iv63s
“Put the Right Spin on Rotating Equipment Revamps,” http://goo.gl/X9RGi5
for this blower. As an indication, the mini- The main lubrication oil pump is a 3,000-
mum suction pressure is 1.02 bara and the rpm screw pump that is coupled to the gear
maximum discharge pressure is 1.51 bara. unit. In addition, an auxiliary lubrication oil
Maximum pressure delta is 0.49 bar. After a pump — an electric-motor-driven pump
thorough optimization, the selected blower (again, a 3,000-rpm direct-driven unit) — is
speed is 9,100 rpm and the motor power is provided; it also is used for startup. Each
570 kW. This is a high-speed blower using pump will supply oil at 9.9 m3/h with 6 barg
a 3,000-rpm induction electric motor and a discharge pressure; each pump has a power
gear unit with gear ratio slightly more than rating of around 5 kW (around 1% of the
3. It has a sophisticated three-dimensional main electric-motor-driver power rating).
semi-open impeller with a diameter exceed-
ing 500 mm and a tip speed of around 225 The volume of the lubrication-oil stain-
m/s. The trip speed is set at 9,900 rpm. less-steel tank is around 850 liters (giv-
This blower has an estimated overall ef- ing around 5-min. oil-retention time). Two
ficiency of 73%. For operational flexibility, aluminum-alloy air-coolers (one operat-
it is equipped with pneumatically actuated ing and one standby) are provided for the
VIGVs as well as a VFD that can adjust lubrication oil system; duplex oil filters are
speed from 50–103% of nominal. Using both fabricated from stainless steel. The speci-
VIGVs and VFD, the minimum flow achiev- fied lubrication oil is ISO VG 46.
able is around 8,500 m /h.
3
Designing and installing mechanical systems with strict standards and short installation
schedules can be complicated. Viega MegaPress provides innovative solutions for hydronic
and fire protection systems. Viega MegaPressG provides innovative solutions for gas and
compressed air systems. Approved for more applications than any other black iron pipe press
system, Viega MegaPress is the solution to meeting tomorrow’s engineering standards today.
• Suitable for ASTM Schedule 5 to Schedule 40 black iron pipe and NFPA 13, 13D and
13R fire sprinkler systems
• Secure press connections made in seconds
• Equipped with the Smart Connect® feature for easy identification of unpressed fittings
• No need for messy and toxic threading or cutting oils
Prevent Paired-Pump
Problems
Operating centrifugal pumps in series demands care
T
he centrifugal booster pump was At startup, Unit 1, Unit 2 and Unit 100 were
vibrating and running hot. The pump available. However, the booster pump
took liquid from two sources and P100 experienced vibration and other
pumped it to a third unit. Figure 1 shows problems.
the original pump installation — as well as
equipment added later and a better option, Without a control device, a centrifugal
as we’ll discuss. pump will operate along its head curve. In
the original configuration shown in Figure
The original plant concept called for initially 1, the upstream level controllers define the
installing two matching modular units, Unit supply rate to P100 while the differential
1 and Unit 2, with a third identical unit, Unit pressure between the suction and dis-
3, to be put in later. Each unit would handle charge conditions sets its discharge rate.
the same specific product, with the streams Unless there’s an amazing coincidence,
then combined and sent to a downstream these rates never will match.
unit, Unit 100, for further processing. Be-
cause the product streams didn’t have How the pump operates in such a situation
sufficient pressure to get into Unit 100, the depends upon the relation between the
design included a common booster pump, supply and discharge rates. In this case,
P100, with a fixed-speed electric driver to P100 was over-sized for both the startup
provide the necessary head. and even the future expanded operation.
and eventually Unit 3, costs more. How- should prompt a reassessment of work
ever, it offers the advantages of smaller processes. How did this configuration get
plot space requirements and lower liquid past hazard-assessment, operability and
inventory. other reviews? What changes in workflow
and responsibilities are necessary to
Having two centrifugal pumps in series prevent such a blunder in the future?
with no flow control in this service is Everyone makes mistakes. Effective orga-
simply a mistake. There is no excuse for nizations learn from their mistakes and
the original configuration. Such an error improve.
PRODUCT FOCUS
The analyzer is said to be ideal for materials and processes that demand the highest levels
of safety and reliability, e.g. in the case of corrosive media like strong acids or alkalis or even
toxic compounds.
at their best
when things
HEAT up!
• Thru-Shaft design
• Live loaded packing
• Temperatures to 900ºF
(1100º with Inconel Seat)
• 150#/300# ANSI/ASME in stock
2”-36”, with 48” available
(513) 247-5465
FAX (513) 247-5462
sales@atcontrols.com
www.a-tcontrols.com
www.chemicalprocessing.com
Increase Process
Availability
Coriolis mass flow meters can provide reliable indication of gas entrainment
E
ntrained gas can disturb the sensitivity THE CHALLENGE OF GAS
of mass flow measurement of liquids, ENTRAINMENT
decreasing accuracy or even stopping Gas entrainment refers to the presence of
measurement completely. New Coriolis mass gas bubbles in a process. It can occur for
flow meter technology has come on the mar- many reasons and particularly in terms of
ket that ensures both stable and uninterrupted sensitive dosing processes, it causes ag-
measurements with high gas content. The new gravation and headaches for users. Gas
meters offer reliable indication of gas bubbles bubbles can form, for example, due to
in the process by using a combination of degassing, leaks upstream of, or in, a nega-
various measurements to detect a two-phase tive pressure area, excessive cavitation and
flow. With values between 0 and 100% gas levels falling below the minimum in supply
or air content in the line, it maintains continu- containers, as well as agitators in tanks or
ous mass density measurement and provides long drop distances for media into tanks.
measured values at all times. At the same time, However, they can also occur due to status
it can report the two-phase status and output transitions in process control, such as when
a preconfigured alarm, in accordance with starting or shutting down the system, or
NAMUR NE 107 requirements. cleaning it.
Figure 1. Advances in technology allow some flow meters to provide accurate measurement
even when gas bubbles are present.
Other examples include production pro- On the other hand, some in the indus-
cesses in which gas bubbles are introduced try caution against making this a bigger
deliberately and the gas flow is measured problem than necessary, arguing that gas
upstream of the sprayer. This can happen, entrainment actually occurs in signifi-
for example, in the production of shower cantly fewer processes than measurement
gels, or processes in which the bubbles are devices might suggest. “Gas bubbles in
used for control purposes. chemical processes are one of the most
frequent reasons that system operators
The effect of gas entrainment should not to call service employees to test a supposed-
be underestimated, because it affects pro- ly faulty device,” explains Frank Grunert,
cess control measurements and thus results global product group manager for Coriolis
in unreliable product quality. Because of mass flow meters at Krohne. “The user is
this, NAMUR recommendation NE 107, “Self- often astonished to find that the meter
monitoring and diagnosis of field devices” for is measuring according to specifications
smart flow measurement processes classi- and the unexpected gas content can be
fies the presence of entrained gas as an error discovered based on the saved density
condition in the highest category, Category 1. changes.”
that amplifies the measured resonant fre- nance. The device remains in continuous
quency of the measuring tube and returns it measuring operation, even if there is gas
to the measuring tube as an impulse signal. content or air pockets of 0 to 100% by vol-
ume in the medium.
In the case of gas bubbles, the vibration
signal is disturbed due to the transients in Different indicators for gas bubbles are set in
the damping and the density of the me- the signal converter, which use cross-sensitiv-
dium. With the analog drive system distur- ities to combine two or more indicators for a
bance recorded and amplified, the impulse reliable diagnosis. According to NAMUR NE
signal is disturbed as well. This means a 107, the most important requirement is that
loss in output because the excitation only the results of the diagnosis be reliable, so that
occurs in the resonance of the measuring the user can take the correct actions.
tube, which is not efficient, and also leads
to a fault in the frequency measurement. For many users, a crucial criterion for select-
Both end up increasing deterioration of the ing a measuring device is the accuracy with
measurement of the tube oscillation and, as which it measures the occurrence of gas
a result, the mass flow measurement. They bubbles. Despite the advances in technol-
also risk losing control of the driver system, ogy, practice demonstrates that even with
which requires a restart of the meter before these devices, gas bubbles cause changes in
measurement can be restored. the processes. This results in variations of
accuracy with mass flow measurement,
The new technology used in the Optimass depending on the process conditions and
6400 has a synthetic driver oscillation and the system operation of interest to the
high resolution digital signal processing: the customer. In addition, gas bubbles can vary
oscillation is produced using a digitally gen- widely in size and frequency of occurrence.
erated — and therefore known — impulse Likewise, there are changes in temperature,
frequency. The measuring tube oscillation pressure or viscosity that need to be consid-
occurs due to this impulse, so the frequency ered. Therefore, users still have to be cau-
of the measuring tube is known precisely. tious regarding accuracy of the various
This connection doesn’t change, even with available measurements in indicating the
gas bubble disturbance. The control loop occurrence of gas bubbles and changing
remains “clean” and is not disturbed by in- process conditions.
terspersed and amplified frequencies. In this
way, the flowmeter can accurately measure STEFFEN BAECKER is flow product man-
amplitudes and phases, even in disturbed ager at Krohne. He can be reached at
conditions, and regulate them in the reso- s.baecker@krohne.com.
Upcoming and
On Demand Webinars TO PCESSING
CAL P O
R
COMI
Tap into expert knowledge. Chemical Processing editors and industry ex-
perts delve into hot topics challenging the chemical processing industry
today while providing insights and practical guidance. Each of these
free webinars feature a live Q&A session and lasts 60 minutes.
White Papers
Check out our library of white papers covering myriad topics and offer-
ing valuable insight into products and solutions important to chemical
processing professionals. From automation to fluid handling, separa-
tions technologies and utilities, this white paper library has it all.
Minute Clinic
Chemical Processing’s Minute Clinic podcast series is designed to tackle
one critical issue at a time — giving you hard-hitting information in
just minutes.