Installation/Operating Instructions

Targa Electric Projection Screen by Draper


Operation
Caution Before operating screen remove tape securing fabric and dowel to roller. If viewing
➀ Read instructions through completely before proceeding. surface hangs out of case 8"-9", tape has probably been broken by rough handling in
➁ Follow instructions carefully. Installation contrary to instructions invalidates warranty. shipment, allowing surface to “unwrap” one turn about the roller. Manually wrap fabric
➂ Screen should be accessible for complete removal should fabric become damaged back around the roller without turning the roller itself.
or should other service be required. 110-120V Single Station Control — 3-position up-off-down switch permits operation to
➃ Screen should be installed level (using a carpenter’s level). be stopped at any point. Factory adjusted limit switches automatically stop screen when
➄ Nothing should be fastened to screen dowel or viewing surface. fully down or fully up.
➅ Operating switch(es) packed separately in screen carton. Do not discard with pack- 110-120V Multiple Station Control—Switches are similar in appearance to 110-120V
ing material. Single Station Control. Screen stops when switch is released and may be restarted in
➆ Screen operates on 110-120V, 60 hz. current. either direction. Factory adjusted limit switches stop screen automatically when fully up
NOTE: Screen has been thoroughly inspected and tested at factory and found to be or fully down.
operating properly prior to shipment. 24V Control — Three-button up-stop-down switches stop at any point desired, operate
These instructions are meant as a guide only. They do not imply any responsibility on the in any sequence. Factory adjusted limit switches automatically stop screen when fully up
part of Draper, Inc. for improper installation or faulty workmanship at the jobsite. or fully down.
Hanging Screen Key Operated Switching — Two kinds of key-operated switches are optionally available
General: with this unit. ➀ The key-operated power supply switch controls power to the screen and
When locating viewing surface and checking clearance for screen’s operation, remember switches. When it is “off ”, the switches will not operate screen. Key may be removed from
surface is centered in case. Handle case carefully to protect its finish. the switch in either “on” or “off” position. ➁ A three-position key switch permits the screen
Regardless of mounting method, screen should be positively and securely supported so to be operated directly by key. In this case, the screen’s operator must always have a key.
that vibration or even abusive pulling on the viewing surface will not cause case to work RS232/Ethernet—Serial communication and network communication optionally available
loose or fall. Installer must insure that fasteners used are of adequate strength and suit- with wall switches, RF or IR remote.
able for the mounting surface chosen. Limit Adjustments—Standard and Quiet Motor
Suspended Installation: Screen has been factory set and should not normally require further adjustment. How-
Suspend screens from holes in endcaps as shown. “S” hooks, chains (or cable) and ever, if you desire to change the “up” and “down” stopping positions, proceed as follows:
turnbuckles should be provided by installer. “S” hooks should go through the front holes CAUTION: Be sure all switches are in “off ” position before adjusting limit switches.
on the endcaps (see drawing on page 2), and both ends of the “S” hooks should be Always be prepared to shut screen off manually when new adjust-ment is being tested.
crimped for additional safety. Chains should be attached to beams or other structural Screen may be severely damaged if viewing surface is allowed to run too far up or too far
members. Turnbuckles should be adjusted so screen hangs level. down.
Wall Installation: Adjusting “fully up” position — “Up” stopping position may be adjusted by turning the
Mount screen through holes in back of endcaps as shown. Installer should furnish yellow limit switch adjustment socket. The yellow socket is located on left end of screen
screws, toggle bolts, molly bolts, nylon or lead anchors as required. roller and is accessible to a screwdriver/Allen wrench (4mm or 5/32"). Turning the socket
Wall Installation with 6" Extension Brackets: counterclockwise will allow the viewing surface to retract farther into the case. Turning it
Mount the brackets (not included with screen—see diagram below right) using hardware clockwise will cause the surface to stop farther out of the case. One full revolution of the
recommended for “Wall Installation” (above). Then, suspend the screen from the front socket will alter the stopping position of the viewing surface by approximately 1½".
holes with “S” hooks (as in “Suspended”). For added safety, crimp both ends of the “S”
Adjusting “fully down” position — “Down” stopping position may be adjusted by turn-
hooks so the screen cannot come off. For a more rigid installation, mount the screen from
ing the white limit switch adjustment socket. The white socket is located on the left end
the back holes to the front of the bracket by using the screws and nuts provided with the
of screen roller and is accessible to a screwdriver/Allen wrench (4mm or 5/32"). Turning
brackets.
the socket counterclockwise will allow the viewing surface to run farther down. Turning it
Recessed Installation:
clockwise will shorten the viewing surface, causing it to stop in a less extended position.
Recess should permit access for removal of screen if necessary. Screen may be
At no time should viewing surface be unrolled enough to expose any part of screen roller.
mounted as in suspended or wall installation. Optional Ceiling Opening Trim Kit available;
see diagrams below and on page 2, and separate instruction sheet (included with Ceiling Limit Adjustments (Built-in Low Voltage Motors)
Opening Trim Kit). ➀ Connect the ILT switch to the motor using four conductor modular cable. The cable
connectors MUST NOT be crimped in reverse, as with standard telephone cable.
Electrical Connections ➁ Set the dip switch with 1 ON and 2 OFF. Press and hold the DOWN arrow on the
Screen operates on 110-120v, 60 hz. current. switch to move the viewing surface to the desired lower limit. If the treatment moves
Junction box is located inside left endcap and cover plate is secured to endcap with in the opposite direction, release the DOWN button and depress the STOP button.
two screws. Junction box contains red, black and white pigtail leads and green internal This will reverse the operation of the UP and DOWN switches.
ground wire, per wiring diagram on reverse. ➂ Move the motor to the desired lower limit and return both dip switches to OFF to
Screen is shipped with internal wiring complete and control switch(es) fully boxed. Wire record position.
connecting screen to switch(es) and switch(es) to power supply should be furnished by ➃ Set the dip switch with 1 OFF and 2 ON. Move the viewing surface to the desired
installer. Connections should be made in accordance with attached wiring diagram, and upper limit by pressing and holding the UP arrow on the wall switch. Return both dip
wiring should comply with National and local electrical codes. switches to OFF to record position and return to normal operation.
All operating switches should be “off” before power is connected. ➄ To set the viewing surface to an alternate format position, move the viewing surface
to the desired position and press the STOP button. Press and hold the STOP button
for at least three seconds to record the position.
Screen Case Please Note: Pressing and releasing the UP arrow on the
switch will move the viewing surface to its upper limit. Press- U D G +
p o r 5V
ing and releasing the DOWN arrow will move the viewing w
n
o
u
n
surface to its lower limit. While the motor is in motion, pressing d

Back the STOP button for less than PO


P OTTSS
two seconds will stop the viewing SW1 SW2 FUNCTION
Ceiling Tile surface at its present position. ON OFF Set LOWER limit
(By others) Once the motor is stopped, Set UPPER limit
OFF ON
pressing the STOP button will Record Position/
1 2
To
OFF OFF Motor
move the viewing surface to its Normal Operation OFF

alternate format position. Press- Back View


ing and holding the STOP button, when the motor is at rest or
in motion, for at least three seconds will record a new alternate format position.
6"

6" Extension
Bracket

If you encounter any difficulties installing or servicing your Targa screen, call your
Copyright © 2007 Draper Inc. Form Targa_Inst07 Printed in U.S.A. dealer or Draper Inc., Spiceland, Indiana, (765) 987-7999 or fax (765) 987-7142.
Targa by Draper Page 2 of 2
Case Dimensions
Types of Installation 5 1/4"
2 5/16" Fabric width + 7"
Wall Mounted Suspended
Appropriate hardware
provided by installer.
5 7/8"

Appropriate hardware
provided by installer. 7/8" dia.
Viewing
electrical 31/2" surface
connection
hole

Wiring Diagrams—110-120V Motor and Quiet Motor


Methods of Installation
Fasteners for Single Station Control Multiple Station Control
wall mounting
by others. Internal Screen Wiring Internal Screen Wiring
S Hooks for White (Common) White (Common)
suspended Black (Down) Black (Down)
installation
by others. Red (Up) Red (Up)
Green (Ground) Green (Ground)
7/8"hole for
electrical Cap off with wire
Dashed wiring
connection. nut and tape
by electrician

Control Single gang box by others Red Blue


switch Min. 4" x 2 1/8" x 1 7/8" deep
Blue
Red Black Dashed wiring
Black
by electrician

Red Blue

Location of key
operated on-off Black
switch if furnished
Optional Ceiling Opening Trim Kit Red Blue
(Dims-Side View) To 110-120V Line Single gang box by others
Black
Min. 4" x 2 1/8" x 1 7/8" deep.
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished

To 110-120V Line

8" Wiring Diagrams—110-120V Motor and Quiet Motor


with Built-in Low Voltage Controller
Single Low Voltage Control Multiple Low Voltage Controls
Internal Screen Wiring Internal Screen Wiring
21/16" White (Neutral) White (Neutral)
Black Black
Green (Ground) Green (Ground)
11/16"
21/8"
4"
Dashed wiring
63/4" Dashed wiring Data Cable by electrician
by electrician
Data
Cables

Wall Switch,
RF or IR
Receiver, Wall Switches,
or integrated RF or IR
control system Receivers,
or integrated
To 110-120V Line control systems
To 110-120V Line

www.draperinc.com (765) 987-7999