news
Hydro Issue 12
November 2007
www.vatech-hydro.com
ILISU 6/7
Aschach 8/9/10
Lower St. Anthony Falls 16
Modernization StrafloMatrixTM
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 2
Content
Introduction 3
Imprint
Publisher
VA TECH HYDRO GmbH
A-1141 Vienna
Highlights 22/23/24 Penzinger Strasse 76, Austria
Phone +43/1 89100 2659
Editorial team
Pierre Duflon, Jens Päutz,
Events/Fairs 25 Frost & Sullivan Africa - Peter Stettner, Georg Wöber,
Kurt Wolfartsberger
Customer Service Leadership
26/27 HYDRO AUTOMATION DAY Copyright © VA TECH HYDRO GmbH 2007
All rights reserved
2007
Graphic design
Idea: Gudrun Schaffer
Layout/Production: A3 Werbeservice
Edition: 19,500
2 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 3
Introduction
Hydro business
Radial Turbine
Modernization
4 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 5
Pressure
(Contour 1)
Hydro business
Electricidad (CFE) for the refurbishment CFD was utilized for the hydraulic opti- efficiency of 91.5 % and 82 MW of
of two units at the La Villita power mization of the modified and new com- power (only 85 % regulating ring
plant. In addition to vibration and ponents. The shape of the new stay opening) being achieved. Other benefits
cavitation problems, poor efficiency was vane profile was perfected together included a reduction in vibration levels
the main reason for this undertaking. with the spiral and guide vanes by of more than 30 % and reduced
Although the four Francis turbines means of 3D flow simulations at differ- downstream water turbulence as
dating from 1973 were designed for ent operating points to ensure precise compared to that experienced with
maximum power output of 76 MW, interaction between the components. In the old turbines.
they never achieved this value and were order to accommodate the variation in
operated at between 50 and 70 MW. the stay vane profiles over the circum- The refurbishment works on unit 3,
Moreover, originally the turbines were ference, the full geometry over 360° which included the repair of compo-
intended for an operating frequency of was modelled. Runner design was opti- nents such as guide vanes, upper and
both 50 Hz and 60 Hz and thus the mized by means of steady state flow lower turbine covers, turbine shaft, etc.
hydraulic design was a compromise. simulations with the aim of achieving were completed during 2007.
However, due to changes in the minimized losses and safe cavitation The units have been in commercial
Mexican grid, today turbines are only behaviour. The interaction with the adja- operation since July 2006 and August
operated at 60 Hz. During operation, cent components was carefully harmo- 2007 respectively to the complete
severe cavitation damage occurred at nized and viscous flow analysis was uti- satisfaction of the customer.
the leading edge of the runners. lized to minimize the losses in each
The units were also suffering from component. Parallel to hydraulic opti- La Villita
Prototype Efficiency Curves From Site Tests
serious vibration problems, which may mization, the mechanical properties Head H = 44 m
1.10
Normalized efficiency [-]
have been caused by the hydraulic were checked closely with the aim of
1.05
design compromise. As a conse- ensuring safe operation and long unit
1.00
quence, cracking had occurred at service life. In order to ascertain the
0.95
several stay vanes. One of the stay hydraulic behavior of the prototype,
0.90
vanes was even fully detached from semi-homologous model testing was Old Runner - U4
0.85 New Runner - U2
the stay ring. Cracks were also evident employed to complete the hydraulic 0.80
on the runner blades between the blade design. The quality of the runner design 20 30 40 50 60 70 80 90
Power [ MW ]
and hub close to the trailing edge. was proven without major changes.
In order to solve these multiple prob- ASTM A743 grade CA6NM was utilised
lems, it was decided to provide two for the welded 53 t runners and there-
units with new runners incorporating an
improved hydraulic design. The profile
fore these had to undergo thorough
heat treatment after welding to alleviate
What’s next?
of the stay vanes was to be modified residual stresses. In the next issue of HYDRO NEWS
and optimized with respect to efficiency During the second half of 2006, we will be discussing in detail possible
and mechanical behaviour, while the VA TECH ESCHER WYSS S. A. DE measures for the restoration of the
draft tube was to remain unchanged C. V. concluded the installation of the reliability and safety of shut-off valves.
although the hydraulic design did not first of two runners, as well as the
correspond with modern criteria. Finally, modifications of the stay vanes and
draft tube fins were to replace the aera- draft tube and other site repairs. The Peter Stettner
tion tripod, in order to ensure smooth performance tests were successfully Phone +43/1 89100 2957
operation behaviour. concluded with mean weighted peter.stettner@vatech-hydro.at
Hydronews 5
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 6
Top story
ILISU
Contracts signed for a
Large Turnkey Power Station
one of Turkey’s largest hydropower engineering consortium, consisting of The power station represents a
projects. The consortium also the Swiss firms Colenco and Maggia pioneering project and a model for
includes the Alstom Hydro and the Turkish companies Dolsar and environmental protection. For the
Switzerland, the Turkish construc- Rast, with the supply of supportive first time in Turkey, the planned envi-
tion companies Nurol and Cengiz, planning and construction supervision. ronmental protection measures will
the German construction company be on the level required by the OECD
Züblin and the engineering firms Once finished, the power station will recommendations and the World Bank
Stucky/Switzerland and have a rated capacity of 1,200 MW, standard. These benchmarks define
Temelsu/Turkey. The contract has which will make it the fourth largest in the minimum requirements in the
been concluded with the Turkish Turkey. Moreover, the increased use of areas of:
Office for Hydraulic Engineering hydropower represents a major contri-
(DSI) and for at least seven years bution by Turkey to climate protection, • Resettlement
will provide employment for as well as bringing a reduction in the • Cultural heritage safeguards
thousands of local people in dependency on imported fuels, as the • Environmental protection (biology,
the poor Tigris province of national reserves of coal are slowly wastewater).
southeastern Turkey. One aspect coming to an end.
of the project is the provision of The additional, special measures
the complete financing with the Other positive effects of the project are related to the project include:
participation of export loan effective flood protection and above all,
agencies in Austria, Germany the sustainable development of one of Resettlement
and Switzerland. Turkey’s most economically backward • Preliminary information and involve-
regions. ment of those affected in basic
decisions relating to resettlement
The scope of delivery of Andritz • The introduction of a “grievance
VA TECH HYDRO includes the model redress mechanism” for the rapid
testing, design, production, transport, handling of claims
installation and start-up of: • The use of at least one additional
harvest by the affected population
• The complete hydraulic steel • The definition of comprehensive
6 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 7
Alexander Schwab
Phone +43/1 89100 2659
alexander.schwab@vatech-hydro.at
Hydronews 7
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 8
Key projects
Aschach
Successful Modernization of Danube
Hydro Power Plant in Austria
8 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 9
turbine lot) was the extremely short existing draft tube. The final shape of were crack tested. During commission-
outage time of only 6 months per unit the runner was obtained by replacing ing, all the planned load points were
and the increase in output. Close coor- the target-velocity profiles with profiles easily reached. Moreover, there was a
dination between the contractors as, derived from sample measurements. tangible improvement in the smooth-
well as extensive manufacturing capa- This procedure provided an ideal pro- ness of unit running within the upper
bilities and engineering capacity in file, which finally fulfilled all require- operating range. The design capacity
Austria, were essential prerequisites in ments. of the generators was increased from
the achievement of the customer’s 85 MVA to 98 MVA and efficiency was
demanding requirements. Disassembly and reassembly repre- enhanced to 98.6% (relative 0.5%).
sented a major challenge for our instal-
In addition to increased regulating lation team. Firstly, the old runner In view of the tightness of the schedule
capabilities and greater efficiency, the chamber had to be cut out with a dia- and the possibility to install four similar
main target was an improvement in mond-tipped, steel wire rope, prior to units, the original plan to simply replace
the cavitation behaviour of the turbine the concreting of the new spherical the stator core and winding was
during full load operation. After full runner chamber. Due to this spherical changed in favour of the replacement
modeling of the existing turbine, the design it was no longer possible to of the complete stator, gliding shoes
CFD (computational fluid dynamics) install the runner in one piece and compensating for the radial expansion
analysis reconfirmed the location of therefore the blades had to be joined of the stator frame. In order to allow
previously identified cavitation. to the hub on the spot. Furthermore, transport, the 13m-diameter stator
the shaft sealing was completely housing was designed in four parts.
Two runner designs were followed up renewed. Maintenance-free bushings The stator housing joints were welded
for optimization purposes and the were installed in the wicket gates and on-site and continuous stacking was
cost-benefit analysis resulted in a the guide vanes were plated with stain- used to avoid any joints in the finished
change of runner diameter to 8,600 less steel. All the main components core.
mm with a hub-to-shroud diameter
ratio of 38%. This decisively increased Winding termination in twelve layers
the flow capability as compared to the
old turbine (hub-to-shroud diameter
ratio 44%). The automatic runner
optimization process was performed
using an evolutionary strategic
algorithm coupled with 3D EULER
and provided an improvement in tur-
bine efficiency and a shift in the cavita-
tion limits to higher discharge values.
Following the CFD analysis, a series of
model tests was completed at ASTRÖ.
Hydronews 9
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 10
Key projects
A further design and installation chal- rotor and stator, were all completed in coordination of the project team, this
lenge concerning limited space condi- Weiz. The Aschach rehabilitation is part proved of great advantage during the
tions was the request for accessibility of a superordinated Verbund AHP proj- extremely short time available for the
of all parallel stator winding paths. ect. In future, all nine Danube power modifications to the first unit, enabling
The winding termination is done in 12 plants will be operated and monitored the combined turbine, generator,
layers where each phase is extended from the Danube control room at the excitation, control and protection
to an outside termination box. The Freudenau power station and to this equipment commissioning within only
stars have external neutral ties. end, the unit and plant automation at 3 weeks. Through 2-shift and partly
The 88 pole windings were reinsulated all the power stations is to be renewed. 3-shift working, the complete outage of
in the workshop in Weiz, the asbestos In this connection and independent of 6 months was only exceeded by a few
insulation having been professionally the unit rehabilitation project, the days and AHP suffered no production
removed and disposed of. The rotor automation unit of Andritz VA TECH losses. All of AHP’s requirements were
was tested for cracks in the power- HYDRO (former VA TECH SAT) was met to its complete satisfaction.
house in teamwork with the Institute awarded an order for the renewal of Disassembly of the second unit started
for Testing and Reseach in Material the unit control, water management, at the beginning of September 2007
Technology (TVFA) and in addition, the excitation equipment and parts of the and the final two units will follow in
brush holders and exciter leads were electrical auxiliaries. Due to the easier 2008 and 2009.
renewed. Evidence regarding the
impact of an increase in output repre-
sented a vital element and a govern- Hydro Service – Austria
mental precondition for the reuse of Hydro Service - Austria (SR-Austria)
existing components. For this purpose is not only completing the large
the recalculation of the rotor shaft Aschach project, as Austria’s
dynamics (critical bending moment, power plants continually require
critical speed, torsion frequencies, a diversity of small and medium
max. shaft and coupling torque), as rehabilitation, repair and mainte-
well as mechanical calculations for the nance work. With its SR-Austria
organization, Andritz VA TECH
HYDRO alone has a market share
Shaft removal amounting to over 600 orders
annually. The scope of services
includes spare parts and compo-
nent supply, installation services,
inspection and assessment, short-
term repairs and modifications,
Mechanical (& Lead)
large audits and overhauls, which
Franz Grundner (middle)
extend to complete automation,
modernization and output increases Phone +43/316 6902 2984
as previously described. Our franz.grundner@andritz.com
strengths in this regard consist of Electrical
extensive manufacturing capacities Gerhard Hofstätter (left)
in Austria, an experienced installa- Phone +43/3172 606 2282
tion pool and complete engineering gerhard.hofstaetter@vatech-hydro.at
and development competence. Automation
The authors of this article are also Michael Hager (right)
the contact persons for Hydro Phone +43/1 81195 6724
Service projects in Austria. michael.hager@vatech-hydro.at
10 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 11
Key projects
Vanessa L. Ames
Phone +1/704 943 4343
vames.@vatechhydro.com
Hydronews 11
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 12
Key projects
Giancarlo Di Zazzo
Phone +39/044 56 78 263
giancarlo.dizazzo@vatew.it
12 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 13
Key projects
Hydronews 13
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 14
Key projects
Modernization in Turkey
Ferdinand Schedl
Phone +43/1 89100 2085
ferdinand.schedl@vatech-hydro.at
14 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 15
Key projects
Hydronews 15
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 16
Key projects
Alexander Bihlmayer
Phone +43/732 74261
alexander.bihlmayer@vatech-hydro.at
16 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 17
Site report
Hydronews 17
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 18
Site report
Donau Chemie’s ambitious target was which had to be handled and dumped
to reopen the plant and start operation in compliance with strict health and
in May 2006. This was a great chal- safety requirements. On March 27,
lenge and all the involved parties were 2006 the first rehabilitated components
required to reduce the lead-time to a were delivered to the site and reassem-
minimum. After the first visual inspec- bly commenced. Commissioning took
tion, the initial plan was to replace the place on May 12, 2006, and on May
stator winding, renew the instrumenta- 19, 2006, generator 8 was released for
Generator 8 covered with mud and debris tion, clean and dry the rotor, rotor poles commercial operation. In line with the
and the remaining parts and carry out generator rehabilitation, the rotating
repairs where necessary. However, exciters of all units were modified to
I n August 2005, flooding in western
Austria caused damage amounting
to millions of Euros. The Wiesberg
during disassembly of the stator wind-
ing, it was discovered that the stator
form modern static excitation systems.
These were supplied and commis-
hydropower plant in Landeck, core also required renewal. Accordingly, sioned by Andritz VA TECH HYDRO’s
Tyrol, was also largely destroyed the original schedule could only be automation unit. The Wiesberg power
by mud and boulders. The plant, maintained though a non-bureaucratic plant, along with the renewal of the
owned by Donau Chemie AG, manufacturing process at our plant intake, flood protection of the power-
provided 2/3 of the power supply involving day and night working. Part of house and remaining civil works, was
for a local calcium carbide plant the success of the project can also be finally completed in May 2007. On
and therefore production was attributed to the German company, September 24, 2007, the official
seriously affected. Partzsch, which as the stator coil and reopening ceremony took place in the
laser-cut stator core sheets supplier, presence of the Governor of Tyrol and
As part of the overall rehabilitation, the was also able to meet the very short all those involved in the project.
Andritz VA TECH HYDRO Service delivery deadlines. The rehabilitation of
Center in Weiz, was awarded the reha- the rotor poles created further chal- Manfred Raith
bilitation of generator 8 and the supply lenges. The rotor winding insulation was Phone +43/3172 606 2235
of a new static excitation system. contaminated with asbestos materials, manfred.raith@vatech-hydro.at
18 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 19
Site report
Josef Brunner
Phone +41/41 329 5312
josef.brunner@vatech-hydro.ch
Hydronews 19
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 20
Markets
Hydropower
A fundamental Element in Spanish
Electricity Generation
ince the end of the 19th to be continuously developed and this possibility has created a
S century, when the first “light
factories” were installed, hydraulic
throughout the entire 20 th century.
This was because until the emergence
renaissance for this type of project in
the short- and medium-term in Spain
power has played an important of other renewable energies in the last and Portugal.
role in the generation of electricity years of the past century, hydropower
in Spain and, as a consequence, was the only energy source to be As a consequence of this reactivation,
independent of external supplies. Iberdrola is in the last phase of
in its industrial development.
awarding the works and equipment
The ease with which hydropower supply for Phase II of the La Muela
The erection of the first hydropower
plants can obtain load is a key feature hydropower plant, with a total output
plant in 1886 for the supply of electrical
that has allowed them to become a of 840 MW, and EDP is in the same
power to the public lighting system in
very important factor in the electrical situation with respect to the 189 MW,
the city of Gerona, represented the
system, covering peak demands and Picote II hydropower plant.
beginning of a hydraulic policy that was
the quick disconnections of thermal The rest of the big electrical utilities on
power plants from the grid. the Iberian Peninsula also have the con-
struction of large pumped storage
This ability to quickly connect and dis- power plants on their agenda for the
connect from the grid has been used near future.
by the hydropower sector in its capacity
as an “electrical power storage battery”, The Andritz VA TECH HYDRO
as it absorbs the excess power gener- Group is well integrated into the
ated by thermal and nuclear plants Spanish hydropower scene
when there is insufficient demand, and
produces electricity when the system Escher Wyss, and later Sulzer, which
so requires. provided the historical background
for today’s Andritz VA TECH HYDRO,
This function of accumulating energy collaborated in the development of
has become of paramount importance hydropower in Spain from the very
due to: beginning at the end of the 19th
century and this support has been
• The necessity to synchronize power maintained over the years by means
generation with electrical demand in of a technological evolution, which
real time has permitted the coverage of the
• The significant development of wind changes that have taken place with
power generation in Spain. regard to hydropower demands.
20 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 21
Markets
Hydronews 21
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 22
Highlights
22 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 23
Highlights
Hydronews 23
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 24
Highlights
24 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 25
Events
Peter Stettner
Phone +43/1 89100 2957
peter.stettner@vatech-hydro.at
Hydronews 25
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 26
Events
HYDRO AUTOMATION
DAY 2007
from SAT to HYDRO AUTOMATION
26 Hydronews
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 27
Hydronews 27
ENGLISCH_HN12_9.Nov. 09.11.2007 14:42 Uhr Seite 28
Hydro Power
focus on
performance
Penzinger Strasse 76
up-to-date technological inventions. A-1141 Vienna, Austria
Phone: +43/1 89100-2659
Utility companies from all over the world value our know-how and commitment
Fax: +43/1 8946046
and trust in the safety and reliability of our tailor-made energy generation
solutions: from equipment for new, turnkey hydropower plants to refurbishment and
overhaul of existing installations and comprehensive automation solutions.
We will continue to set up milestones in harnessing water power jointly with our contact@vatech-hydro.com
customers. We focus on the best solution – from water to wire. www.vatech-hydro.com