MECHANICAL REVIEWER
A stream of high-velocity temperature-controlled air which is directed downward, across an
1 opening Air Curtain
A package assembly of air conditioning components which provides for the treatment of air
2 it is distributed to an air conditioned space. AHU (Air Handling Unit)
A device designed to stop an elevator car or counterweight from descending beyond its
3 normal limit of travel Bumper
The portion of the hoist way extending from the threshold level of the lowest landing door to
4 the floor at the bottom of the hoist way. Elevator Landing
When the elevator car rest on its fully compressed buffer, there shall be a vertical clearance
5 of not less than between the pit floor and the lowest structural or mechanical part. 610 mm.
There shall be installed in the pit of each elevator where the pit extend more than ___
6 below the sill of the pit access door 660 mm
Consist of a platform or car traveling in vertical guides in a shaft or hoist way, with related
9 elevator
hoisting and lowering mechanisms.
10 Device for heating water or generating steam above atmospheric pressure. boiler
11 A system for transporting materials from one site to another, especially in a factory conveyor
Machine that decreases the volume and increases the pressure of a quantity of air by
12 compressor
mechanical means.
A device that maintains, control of the indoor environment—its desirable temperature,
13 humidity, air circulation, and purity for the occupants of that space or for the industrial air-conditioning
materials that are handled or stored there.
14 Device that convert electrical energy into mechanical energy, by electromagnetic means. alternator
15 A machine that converts mechanical energy into electrical energy called generator
Device for reducing the temperature of a liquid, usually water, by bringing it into contact with
16 an airstreams where a small portion of the liquid is evaporated and the major portion is cooling tower
cooled.
A machine often provides the most convenient and economical means of transporting
17 dumbwaiters
relatively small articles between levels.
19 Are vertical tracks that guide the car and counterweight? guide rails
Are rectangular blocks of cast-iron stacked in a frame, which is supported at the opposite
20 counterweight
ends of the cables to car is fastened.
22 Are fastened to car frame and counterweight at top and bottom. governor
1/12
PREPARED BY:
ALEXANDER SAN ANDRES
MECHANICAL REVIEWER
23 Is a device to absorb the impact of car or counterweight at the lower limit of travel? buffer
24 A device use for moistening the air at the desired degree? humidifier
An air-conditioning system in which the air is treated by equipment at one or more central
25 locations outside the spaces served and conveyed to and from these spaces by means of centralized air con
fans and pumps through duct and pipes.
26 Its function is to dispose the heat carried away from the condenser compressor
27 Type of elevator that is raised or lowered quite simply by means of movable rod or plunger? hydraulic elevator
45 A material which stops the transfer of heat is also known as? insulation
2/12
PREPARED BY:
ALEXANDER SAN ANDRES
MECHANICAL REVIEWER
56 pipe fitting with outside threads use for connecting pipes Closed nipple
3/12
PREPARED BY:
ALEXANDER SAN ANDRES
MECHANICAL REVIEWER
A graph used in air-conditioning and showing the
78 Psychrometric Chart
properties of air-system mixtures.
79 Heat that raises air temperature. Sensible Heat
The transmission of heat energy from one place to another
80 Convection
by circulatory movement of a mass of fluid.
What is the rating index of an airconditioning/
refrigeration system which rates the unit for the Energy Efficiency
81
number of BTU's of heat removed per watt of electrical input Rating
energy? (EER)
What mechanical equipment, coupled with a central airconditioning
82 system, is used to to dehumidify and cool the air Fan Coil Unit
stream injected to a conditioned space.
In elevator, it detects the obstacles during the door closing,
83 and reopens the door if there is something. Photocell can be Safety Shoe
used together with this.
It prevents passengers from falling into the hoistway when
84 they try to get out of the car which is stopped between the Fascia Plate
floors.
In elevator, it makes the buzzer alarm when the car is
85 overloaded and the door remains open until overloading is Weighing Device
eliminated.
86 In elevator, it protects the equipment from over current. Circuit Breaker
In elevator, these prevent the excessive car travel at the
87 Limit Switches
highest and lowest floor.
In escalators, these stop the escalator if a foreign object Handrail Guard
88
becomes wedged at the guard. Switches
In escalators, this is located at the bottom truss of the escalator and provided with on and
89 off positions to stop or Disconnect Switch
prevents the escalator from starting during maintenance service.
This device, in escalators, is provided at the drive unit Mechanical
90 location to protect against accidental movement of the escalator Maintenance Locking
during inspection of the drives or during general maintenance. Device
This device, in escalators, stops the escalator automatically Current Overload Safety
91
if an abnormal current is supplied to the motor. Switch
This switch cuts off all current supply to the escalator for
92 Knife Switch
inspection, maintenance, or repairs.
The cooling effect obtained when 1 ton of ice at 32 oF (0
93 Ton of Refrigeration
oC) melts to water at the same tmeperature in 24 hrs.
An assembly consisting of a pulley wheel, side plates,
94 Sheave
shaft, and bearings over which a cable or roped is passed.
Consist of a flyball or flyweight device designed to stop
95 Governor
an elevator.
In theater stage house, a weight usually of iron or sand
96 Counterweight
used to balance suspended scenery, or the like.
On elevators, a gear-driven machine having a drum to
97 which the wire ropes that hoist the car are fastened, and on Winding-Drum Machine
which they wind.
Vertical tracks that serves as a guide for the car and the
98 Winding-Drum Machine
counterweight.
In boilers, they function only when it exceeds prescribed Limit Controls and
99
unsafe operating conditions. Interlocks
The following are basic component parts of an escalator
100 governor
except____.
101 Which of the following is not a component of a hydraulic elevator? counterweight
The following are elements of centralized airconditioning system
102 Method of cooling
except _______.
4/12
PREPARED BY:
ALEXANDER SAN ANDRES
MECHANICAL REVIEWER
A mechanical device used to
103 A transformer is ______. step up or step down voltage
in ac
A factor used in calculating cooling load that includes heat
104 Thermal load
transferred from walls, doors, ceilings, etc. is known as _____.
The following are ways in which heat may be transferred
105 Polarization
except____.
The typical truss configuration used in the installation of an
106 3 section truss
escalator.
Which is the following characterizes centrallized airconditioning a. It uses ducts
b. Has cooling tower
107 All of these
c. Provided with air handling unit
d. All of these
The total cooling output of an airconditioner during its annual
Seasonal energy
108 usage, in BTU/hr divided by the energy input during the same period,
efficiency ratio
in watt-hours is known as_____.
Which type of refrigerant is recommended for residential,
109 commercial, and industrial application using split type airconditioning R-22
system?
The term impedance is used in transformers and other devices in Resistance and
110
ac is a combination of _______. reactance
A continuous belt (chain) attached to the handrail and directly
111 Endless belt
connected to the steps is known as _____.
What is the minimum distance between the handrails of
112 558mm
escalators?
What aspect/s of environment or surroundings is/are considered
in air-conditioning system for human comfort?
113 Both a and b
a. Temperature of the surrounding air
b. Motion of air
114 What is the refrigerant name of R-12? Dichlorodifluormethane
BUGLARS AND
118 They were deter to the intrusion alarm system in residential signal system
PROWLERS
119 An air passage usually formed in sheet metal with insulation for ventilating on a building AIR DUCT
A hoisting and lowering mechanism with a building equipped with relatively small car
123 DUMBWAITER
excusively for carrying materials
124 The device for maintaining desirable humidity conditons in the air supplied HUMIDIFIER
5/12
PREPARED BY:
ALEXANDER SAN ANDRES
MECHANICAL REVIEWER
ACOUSTICAL LAY IN
128 The acoustical ceiling board design to be laid in an exposed grid suspension system
PANEL
Fire tube boliers shall be provide with sufficient room for removal or replacement of tube
131 REAR OR TOP
either from these places
132 The process of dissipating sound energy by converting it to heat SOUND ABSORPTION
The system of deadening sound materials to wall, ceiling, floors to prevent sound from
133 SOUND INSULATION
passing through the members into adjoining room
The illuminance produce by luminous flux of the one lumen distributed uniformly over a one
134 LUX
square meter surface
Package assembly of air conditioning components which provides for the treatment of the
136 AIR HANDLING UNIT
air before it is distributed to an air conditioned space
137 This is the criteria in selection of an elevator other than interval and average waiting time TRAVEL TIME
140 The criteria in the selection of an elevator other than interval and average waiting time TRAVEL TIME
141 Type of conveyor that transport packages equipment crates FREIGHT ELEVATOR
Important element of an elevator below the first level floor line that absorbs and minimize
142 BUFFER
building shocks to the car
That portion of the hoistway in the elevator extending from the threshold level of the lowest
143 PIT
landing floor of the hoistway
144 A geared drive machine in which the suspension ropes are fastened to and wind on a drum WINDING DRUM MACHINE
145 Vertical tracks that serves as a guide for the car and the counterweight GUIDE RAILS
146 Car pit clearance depth from the bottom of the car 600mm
When machine room or penthouse is provided at the top of the hoistway, it shall have a FOR REPAIR AND
147
sufficient room for this INSPECTION
148 When 4 or more elevator serve all or the same portion of the bulding 2 HOISTWAYS
151 Minimum number of hoisting ropes for drum type elevators 2 HOISTWAYS
6/12
PREPARED BY:
ALEXANDER SAN ANDRES
MECHANICAL REVIEWER
Activate by preventing the door to open during elevator car run, the door elevator will open
160 DOOR LOCK SWITCH
only when the car stops at the floor
Activate if the car travel faster than its travel speed, the power will turn off, and grasp the
161 MAGNETIC BREAK
rope to operate the safety gear
Safety device of a passenger elevator which activates if the car travels faster than its rated
163 GOVERNOR
speed by grasping the guide rail to stop the car safely
A European brand of
164 OTIS-U.S.
elevator
A safety device of a passenger elevator which reduces the collision shock of a car
165 or counterweight due to over travel beyond the lowest stop. It stops the car or BUFFER
counterweight safely
A passenger elevator safety device which protects the motor and electrical parts
167 CIRCUIT BREAKER
from over current
The elevator door components that detect the obstacle during the door closing and
169 SAFETY SHOE
re opens the door
170 Dividing the travel length by the rated speed WAIT INTERVAL
Activate by preventing the door to open during elevator car run, the door elevator
171 DOOR LOCK SWITCH
will open only when the car stops at the floor
Activate if the car travel faster than its travel speed, the power will turn off,and
172 MAGNETIC BREAK
grasp the rope to operate the safety gear
Device that open and closes the electric current in an elevator when it has reached
174 LIMIT SWITCH
the designated end of travel course
175 Minimum angle of inclination of an escalator 35 degrees
7/12
PREPARED BY:
ALEXANDER SAN ANDRES
MECHANICAL REVIEWER
180 Maximum rated speed measured along the angle of inclination 38 mpm
R.C CONCRETE OR
181 Provision for boiler rooms inside the building
MASONRY
183 No part of the boiler shall be closer to this from the wall 1 meter
184 Distance of the smokestacks above the building within 50 mts. radius 5.00 mts
185 Provision between any feed pump and the boiler in addition to the regular shut-off valve 2 CHECK VALVES
188 Provision for boilers having generating capacity exceeding 907 kg/hr TWO SAFETY VALVE
190 Temperature and humidity of the air to be used for comfortable cooling 68deg-74deg F
2.30 meters ABOVE THE
191 Minimum for refrigerant piping crossing a passageway in any building
FLOOR
192 Provision of installation for refrigerant system containing more than 9 kgs. STOP VALVES
193 Minimum for window type AC installed on ground floors 2.13 meters
Mechanical equipment coupled with a central air conditioning system used to dehumidify
194 FAN COIL UNIT
and cool the airstream injected to the conditioned space
1.5 TIMES MORE THAN
195 Spacing provided for elevator with single bank in a non residential building THE ELEVATOR CAR
DEPTH
Recording calls even when car is in use. It answer calls starting from the highest and so on DOWN COLLECTIVE
196
while descending CONTROL
Recording calls even when car is in use. It answer calls starting from the lowest and so on UP COLLECTIVE
197
while ascending CONTROL
199 main drive chain, step chain, handrail, drive chain, bottom sprocket ESCALATOR'S PART
When planning a multiple system of elevator layout where four or more elevator are ONE IN FRONT OF THE
200
arrange in banks OTHER
201 Nominal size of an escalator; escalator's width like those in Japanese brand 1120;980;800;760
202 Nominal size of an escalator; escalator's step like those in Japanese brand 1150;1100;1000;900
Type of dampers installed at supply ducts, which are electro-mechanically activated by ADJUSTABLE LOCKING
203
building automation system to close in case of fire within the area DAMPERS
AT THE ESCALATOR
204 Location of Control System or computer brain of the escalator
MACHINE ROOM
8/12
PREPARED BY:
ALEXANDER SAN ANDRES
MECHANICAL REVIEWER
This is a guide for the initial estimate per Ton of Refrigeration per sq.mts. of a standard 12 to 14 SQ.MT PER TON
205
room of normal condition without external solar heat gain and excessive internal heat gain OF REFRIGERATION
STANDARD
INSTALLATION OF
THE TOP CHORD OF THE TRUSS IS WITH A STEEL ANGLE SUPERIMPOSED ON THE
207 ESCALATOR NOT
BUILDING'S STRUCTURAL BEAM EXCEEDING 4.50 MTS./
TRUSS
208 Safety device caused by insufficient water flow on heater when brown out PRESSURE RELIEF VALVE
EXPANDED
209 Vital part of Solar Water heater to keep the heat in and cold out POLYTHELYNE FOAM
INSULATION
KNOCKDOWN BY MAJOR
210 Packaging and assembly of elevator as it arrives on the site
COMPONENT PART
211 Cool the condenser unit in a central conditioning system COOLING TOWER
Rating index of an air conditioning system which rate the number for the unit of BTU heat SEASONAL ENERGY
212
moved per watt of electrical input energy EFFICIENCY
213 Standard unit rating to describe the capacity of the cooling tower TONS OF REFRIGERATION
A device installed on electric water heater used to detect the working temperature to to
214 THERMOSTAT
activate a switch
A safety device of a passenger elevator which reduces the collision shock of a car or
215 counterweight due to over travel beyond the lowest stop. It It stops the car or counterweight BUFFER
safely
Rating index of an air conditioning system which rates the unit for the number for BTU of
heat moved per watt of electrical input energy Internal electronic safety features of an MONITORING CONTACTS
216
escalator. They function as a safety switches or detectors which monitors internal ON STEP CHAIN
mechanical or electrical abnormalities and shuts down the system in any eventuality
A passenger elevator safety device which protects the motor and its electrical parts from
217 CIRCUIT BREAKER
over current
The elevator door components that detect the obstacle during the door closing and re
218 SAFETY SHOE
opens the door
219 Mechanical equipment install on top of the main doors used to retain cold in the interiors AIR CURTAIN
220 Dividing the travel length by the rated speed WAIT INTERVAL
Major physical restriction does a split type air conditioner system have which restricts its EVAPORATORS CANNOT
221
efficiency and performance BE LOCATED AT CEILING
Activate by preventing the door to open during elevator car run, the door elevator will open
222 DOOR LOCK SWITCH
only when the car stops at the floor
223 Opening of door for passenger in case of power failure in the elevator OUTSIDE DOOR LATCH
Activate if the car travel faster than its travel speed, the power will turn off, and grasp the
224 MAGNETIC BREAK
rope to operate the safety gear
226 Device that open and closes the electric current in an elevator when it has reached the LIMIT SWITCH
9/12
PREPARED BY:
ALEXANDER SAN ANDRES
MECHANICAL REVIEWER
Coupled with central air conditioning system, used to dehumidify and cool the air stream
228 FAN COIL UNIT
injected into the conditioned space
The amount of heat which is absorbed or evolved in changing the state of a substance
229 Latent Heat
without changing its temperature.
230 Two types of passenger elevator. Electric and Hydraulic
Minimum elevator width of single slide door elevator for small commercial or residential
231 0.60 mtr.
building.
232 Another name for passenger elevator. Lift
233 The minimum face to face distance between elevators in three and four car grouping. 2 mts.
241 A stop valve placed in the service pipe close to the connection at the water main. Corporation Stop
An Instrument which responds to changes in temperature, and directly or indirectly controls
242 Thermostat
temperature.
243 Thin sheets that are used for controlling heat in drywall construction. Rigid Board Insulation
A machine that converts mechanical energy into electrical energy, a generator of
244 Alternator
alternating current.
245 Freon in air-con must be compressed and liquefied in order to absorb ___. Heat
A device installed on an electric water heater used to detect the working temperature to
246 Thermostat
activate a switch.
During elevator emergency, to rescue passengers, this part of the elevator is used to open
247 Outside Door Latch
the doors from the outside.
A device which extends across at least 1/2 the width of each door leaf which will open if
248 Panic Bar
subjected to pressure.
249 Heat rating for a fixed temperature heat detector. 135-197˚F
An automatic device used for converting high, fluctuating inlet water pressure to a lower Pressure Regulating
250
constant pressure. Valve
251 An air-operated device used to open or close a damper or valve. Air Motor
In theater stage house, a weight usually of iron or sand used to balance suspended
252 Counterweight
scenery, or the like.
On elevators, a gear-driven machine having a drum to which the wire ropes that hoist the
253 Winding-Drum Machine
car are fastened, and on which they wind.
254 Vertical tracks that serves as a guide for the car and the counterweight. Guiderails
Under NBC, the clearance between the underside of the car and the bottom of the pit shall
255 600 mm
not be less than ___.
256 Under NBC, the minimum diameter of hoisting and counterweight rope. 30 mm
10/12
PREPARED BY:
ALEXANDER SAN ANDRES
MECHANICAL REVIEWER
257 Under NBC, the minimum width between balusters in an escalator. 558 mm
258 Under NBC, the maximum rated speed of an escalator along the angle of travel. 38 Meters/Min
262 A graph used in air-conditioning and showing the properties of air-system mixtures. Psychrometric Chart
In elevator, it detects the obstacles during the door closing, and reopens the door if there is
267 Safety Shoe
something. Photocell can be used together with this.
It prevents passengers from falling into the hoistway when they try to get out of the car
268 Fascia Plate
which is stopped between the floors.
In elevator, it makes the buzzer alarm when the car is overloaded and the door remains
269 Weighing Device
open until overloading is eliminated.
270 In elevator, it protects the equipment from over current. Circuit Breaker
271 In elevator, these prevent the excessive car travel at the highest and lowest floor. Limit Switches
Handrail Guard
272 In escalators, these stop the escalator if a foreign object becomes wedged at the guard.
Switches
In escalators, this is located at the bottom truss of the escalator and provided with on and
273 Disconnect Switch
off positions to stop or prevents the escalator from starting during maintenance service.
This device, in escalators, is provided at the drive unit location to protect against accidental
274 Mechanical
movement of the escalator during inspection of the drives or during general maintenance.
This device, in escalators, stops the escalator automatically if an abnormal current is Current Overload Safety
275
supplied to the motor. Switch
This switch cuts off all current supply to the escalator for inspection, maintenance, or
276 Knife Switch
repairs.
The cooling effect obtained when 1 ton of ice at 32 oF (0 oC) melts to water at the same
277 Ton of Refrigeration
tmeperature in 24 hrs. (equivalent to 12,000 Btu/hr)
278
279
280
281
282
11/12