Sie sind auf Seite 1von 15

2011 R+D Products

Ram Rajan

Property of Elma Electronic Inc.


Liquid Cooled 1 ATR (CAP003919)

 Electron Beam welded version with OVPX BP


 First round of Temp testing completed
.

www.elma.com Property of Elma Electronic Inc.


CAP003876 (Composite ½ ATR) R+D

Size: 270mm x 124mm x 320.5mm


Weight: 7.15 lbs
# slots / BP: 6-slots / 3U VPX
Input Voltage: 28VDC
Output Power 250W
I/O Cabling: Ethernet, USB

www.elma.com Property of Elma Electronic Inc. 3


Elma SFF VPX chassis (CAP003975)

APPROXIMATE WEIGHT OF ENCLOSURE IS 7.5 LBS


DOES NOT INCLUDE PSU, BACKPLANE, HDD, I/O CONNECTORS

Size: 130mm x 175mm x 235mm


Weight: 7.5 lbs
# slots / BP: 3-slots / 3U oVPX
Input Voltage: 18-48VDC
Output Voltages: 5V, 3.3V, 12V
I/O Cabling: USB, VGA, SATA, Serial
COM, DVI, Ethernet

Back Panel I/O

2.5” Hard Disk Drive

Front

Power Supply

Captive Hardware
on Front Panel Only
www.elma.com Property of Elma Electronic Inc. 4
Exploded View (CAP003975)

Top Cover

Back Panel
Cold Plate Left Side

2.5” Drive Tray


Backplane

Power Supply
Cold Plate Right Side

Front Panel

Bottom Cover
www.elma.com Property of Elma Electronic Inc. 5
Elma SFF VPX chassis (CAP004007)

APPROXIMATE WEIGHT OF ENCLOSURE IS 8.8 LBS


DOES NOT INCLUDE PSU, BACKPLANE, HDD, I/O CONNECTORS

Size: 130mm x 175mm x 310mm


Weight: 8.8 lbs
# slots / BP: 3-slots / 3U oVPX
Input Voltage: 18-48VDC
Output Voltages: 5V, 3.3V, 12V
I/O Cabling: USB, VGA, SATA, Serial
COM, DVI, Ethernet

Back

3 Slot VPX Backplane

2.5” Hard Disk Drive

Front

Captive Hardware
on Front Panel Only
www.elma.com Property of Elma Electronic Inc. 6
Exploded View (CAP004007)

Top Cover

Cold Plate Left Side Back Panel

Backplane

2.5” Drive Tray

Power Supply
Cold Plate Right Side

Front Panel

Bottom Cover

www.elma.com Property of Elma Electronic Inc. 7


Elma SFF VPX chassis (CAP003994)

TYPE SFF (Small Form Factor


(133H x 180W x 250DP)

www.elma.com Property of Elma Electronic Inc. 8


III Gen ATCA 40G Platform

 Base Chassis part no CAP003796


 Thermal simulation report available
on request
 Airflow and thermal testing report
available
 SI analysis report available on
request
 SI test report available on request
 40G compliance successfully
demonstrated at AIW held at Schroff
 User manual in process

www.elma.com Property of Elma Electronic Inc. 9


Radial IPMB Shelf Manager – ATCA

Key Features:
 For bused or radial ATCA chassis
 5W max power
 32-bit RISC processor @ 400MHz
 32Kbyte FRAM for log messages
 Quad 10/100 Ethernet ports
 RS-232 Debug port
 Linux release 2.6.21
 Field upgradable with dual boot flash
 IPMI 2.0 compliant
 Telco alarms
 Isolated DC/DC converter
 Active/standby redundancy when utilizing two
Shelf Managers in system
 Rich set of Management software (refer to the
VT002 specification for all software
components) such as HPI, RMCP, SNMP, CLI,
HTTP, etc.
 Can run as an IPMI protocol analyzer to
monitor all the 40+ I2C busses

www.elma.com Property of Elma Electronic Inc.


Full featured Voltage Monitor – CAE030738

The new voltage monitor (VM) Replaces current std voltage monitor CAE001354

 32-bit, ARM (embedded variant of processor used in Iphone), Cortex M3 based


hardware platform has various features which are software programmable

 Option to use as full featured or more basic depending upon the design requirements

 Software can be modified to implement any logic

 Hardware and software features listed separately to give an idea of VM feature scope

 Picture shown below is a fully populated VM circuit assembly

www.elma.com Property of Elma Electronic Inc.


Elma DVT LAB

www.elma.com Property of Elma Electronic Inc.


Elma DVT LAB capabilities

 Airflow Testing
 Thermal Testing
 Temperature Testing
 Humidity Testing
 Sound testing
 Radiated Emissions
Testing
 Shock/Vibration Testing

www.elma.com Property of Elma Electronic Inc. 13


Environmental chamber testing

Test Standards:

 MIL-STD-810 Method 501.4 High Temperature


(Storage and Operating). Method 502.4 Low
Temperature (Storage and Operating). Method
507.4 Humidity.

 RTCA/DO-160D Ground Survival Low Temperature


and Operating Low Temperature Test. Ground
Survival High Temperature and Short Time
Operating High Temperature Test. Operating High
Temperature Test.

 GR-63-CORE (NEBS) Low Temperature Exposure,


High Temperature Exposure, High Relative
Humidity Exposure.

www.elma.com Property of Elma Electronic Inc. 14


New environmental chamber – Elma PA

Thermotron Model SE-600-6-6


Environmental Test Chamber

 8800 LCD PC Controller


 Temperature Range -70ºC to +180ºC
 Up to 15ºC/Minute Thermal Ramp
Heating and Cooling
 Humidity 10% to 98%
 Internal Dimensions 49”W x 26”D x 34”H

www.elma.com Property of Elma Electronic Inc.