Sie sind auf Seite 1von 6

320 GC Excavator KTN00001-UP (MACHINE) POWERED BY C4.4 Engine(M008523...

Page 1 of 6

Shutdown SIS

Previous Screen

Product: EXCAVATOR
Model: 320 GC EXCAVATOR KTN
Configuration: 320 GC Excavator KTN00001-UP (MACHINE) POWERED BY C4.4 Engine

Systems Operation
Next Generation Hydraulic Excavator Monitoring System
Media Number -M0081165-01 Publication Date -01/08/2015 Date Updated -13/03/2018

i07105794

Warning Operation
SMCS - 7490

Event Indicator Area toward the top of the Monitoring System Display

Illustration 1 g06226416
(1) Pop-up Event Message

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 7/13/2019
320 GC Excavator KTN00001-UP (MACHINE) POWERED BY C4.4 Engine(M008523... Page 2 of 6

Illustration 2 g06226443
(2) Event Icon List

The Monitor will activate, display, and log events for machine conditions that are not within normal
operating parameters. The Monitor will detect some of the events that are not within normal operating
parameters. However, many of these events are detected by the other control modules on the machine.

The Monitor receives this event data from the other control modules via the Cat® Data Link. The level
of the warning response will be determined depending on the severity of the problem. The event
warnings are classified into three warning levels. The warning level determines which response is
required by the operator. Warning Level 1 represents the least severe problem and Warning Level 3
represents the most severe problem. The warning levels, monitor response, and the required operator
actions are given below.

Warning Level 1 - Graphic Display - requires operator awareness.

Warning Level 2 - Graphic Display and Action Lamp - requires a change in the operation of the
machine or a change in the maintenance of the machine to correct the condition.

Warning Level 3 - Graphic Display, Action Lamp, and Action Alarm - requires immediate shutdown
of the machine to prevent damage to the machine or personnel.

When multiple warnings are present in the system, the highest warning level is shown first. Press the
arrow keys to view all the logged warnings. If no keys are pressed within 5 seconds, the display will
return to the highest level warning.

Note: All the warnings that are listed may not be applicable to all machine models.

Table 1
Warning Messages

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 7/13/2019
320 GC Excavator KTN00001-UP (MACHINE) POWERED BY C4.4 Engine(M008523... Page 3 of 6

Security System Active


Security System Active (HESS)
Operator Override Hot Shutdown
Active Regen
Key Off Regen
Engine Cooldown Active
Service Required
Engine Fault Shutdown Safely
Inlet Air Temp Power Derate
Engine Oil Pressure Power Derate
Fuel Filter Plugged Power Derate
Coolant Temp High
Hydraulic Oil Temp High
DPF Level High Shutdown Safely
Starter Over Heat
ECM Error
Counterweight Removal
Quick Coupler Unlock
100% Load
Cancel Auto Stop
Lift Overload Warning
E-Fence System Backup Switch On
Limited Mobility Mode
Engine Shutdown Pending
Engine Shutdown Idle Time Exceeded
Regen Disabled
Engine Fault Check Engine
Tool Control Malfunction
Travel with Lift Out of Work Area

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 7/13/2019
320 GC Excavator KTN00001-UP (MACHINE) POWERED BY C4.4 Engine(M008523... Page 4 of 6

DPF Level High Regen Required


Engine Oil Pressure Low
Battery Voltage Irregular
Coolant Temp Power Derate
Hydraulic Oil Temp Power Derate
Hydraulic Return Filter Plugged
Water Separator Full
Attachment Filter Plugged
Hydraulic Oil Temp High (Tool)
Lever Is Not Neutral
Cycle the Lock Lever
E-Fence System Interfering
Reverse Fan Error
90% Load
Boom Out of Work Area
Stick Out of Work Area
Hook Interfering
Fuel Level Low
Bucket Cylinder Stroke End
Engine Over Speed Warning
Fuel Pressure High
Fuel Filter Plugged
Intake Air Filter Plugged
Coolant Level Low
Engine Oil Level Low
Hydraulic Oil Level Low
Check Filter/Fluid Information
Fasten Seat Belt
Regen Condition Not Met

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 7/13/2019
320 GC Excavator KTN00001-UP (MACHINE) POWERED BY C4.4 Engine(M008523... Page 5 of 6

Regen Condition Engine Temp Low


Regen System Fault
Glow Active
Low Battery Elevated Idle
Warm-Up Mode Power Derate
Intelligent Hammer Active
Reverse Fan Starting
Quick Coupler Locking
Verify Tool Locking
Bucket In
Crane System Off
Deceleration Area
Retract Sliding Stick

Event Icon List

Illustration 3 g06223816

The Event Icon List display all active events. The list orders the higher-level warnings first, with the
red furthest left, and grey furthest right. The current selected icon will be highlighted with yellow bow
surrounding the icon. Turn the jog dial left and right to change the highlighted icon and press down on
the jog dial to navigate to the highlighted icon pop-up message.

Arrows will appear at either side of the icon list if there are too many icons to display on a single bar.
The arrow will navigate to the next set of icons instantly rather than the next icon from the bold one.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 7/13/2019
320 GC Excavator KTN00001-UP (MACHINE) POWERED BY C4.4 Engine(M008523... Page 6 of 6

Copyright 1993 - 2019 Caterpillar Inc. Sat Jul 13 23:52:49 UTC+0700 2019
All Rights Reserved.
Private Network For SIS Licensees.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 7/13/2019

Das könnte Ihnen auch gefallen