Problems in Domestic WWTP Operations and Corrective Action

No Types of Problems Cause Corrective Action


1 In Tubs Wastewater equalization Wastewater pump in the Check pump electricity,
overflows pump tub is not running or or check automatic pump
the pump filter clogged float position,
clean the filter pump from
impurities
2 Flow of wastewater into the reactor Wastewate pump in the Check the wastewater
is slow equalization tubs is not pump, checking the water
smooth or the meter is meter screen is clogged or
clogged with dirt not. If the clog has to be
cleaned.
3 Air blowers in the aerobic tub works air duct pipe are leak Remove the pipe and then
but does not blow out air connect again with
paralon glue
4 Air blowers in the aerobic tub not Electricity does not flow Check the electrical
work installation to blower
5 Floating Occurs in the aerobic tub Less air Check flow of air
distributors from blowers
6 Quality of processed wastewater  Process of  Setting wastewater
does not meet environmental quality decomposing waste is discharge on average
standards reduced because according to capacity
microbial activity is  Check Blower and air
weakening discharge pipe. In the
 Blowing air in the event of a leak
aerobic unit is lacking. immediately repaired.
 Discharge of
wastewater exceeds the
capacity of WWTP
7 Processed water that comes out still Less air supply, Check blower is working
smells wastewater discharge properly or not.
exceeds the capacity of Addition of decomposer
WWTP, microbes is bacteria.
reduced.