Beruflich Dokumente
Kultur Dokumente
Continuous development and innovation will allow the user to expand their
clinical indications for use and applications in the future. In the modern OR,
intraoperative imaging is an integral tool for the surgical team striving for the
best patient outcomes.
The O-arm System has brought intraoperative imaging to a new level, with
superior image quality and large eld-of-view in both 2D & 3D image sets,
providing surgeons with the information they need most, precisely when they
need it. This allows the surgeon to plan, implement and con rm success of the
surgical procedure before the patient leaves the OR.
The completely motorized system supports quick and easy handling and a
smooth work ow, allowing the surgeon to work in a better-controlled
environment and therefore to focus entirely on the patient. Image quality,
patient safety, sterility and ease of use in the OR are essential design criteria
for the O-arm system. The system optimally supports the surgical work ow
and creates a controlled surgical environment by minimizing manipulations
needed during the procedure. With the unique and patented breakable gantry
the O-arm provides vital lateral patient access, which is essential for optimal
patient positioning and surgical work ow. Compatibility with standard
radiolucent operating tables allows an easy adaptation to any standard OR.
Through robotic positioning the O-arm System remembers your best views.
Programmable memory stores the exact position of the gantry and detector as
Source: Medtronic
well as any X-ray technique, in up to four imaging positions. The user can
recall the exact image position at the touch of a button any time during
surgery, eliminating time-consuming repositioning and additional X-ray
exposure for scouting.
When not needed for imaging, the gantry moves to the user-de ned park
position within seconds, allowing surgeon’s patient access while maintaining
the integrity of the sterile eld as the O-arm can remain in the surgical eld.
As the O-arm is fully mobile, it can be removed from the OR at any time of the
surgery and be used in a parallel intervention.
Automatic Data Transfer of the patient’s 3D data set, as well as of the AP and
lateral images, and automatic anatomical registration on the Stealth Station
Navigation System eliminating the need for lengthy patient registration,
allowing the surgeon to navigate within seconds after image acquisition,
thereby increasing procedural ef ciency.
The experience gained over the years is passed on to new users by supervisors
in training centers and by on-site Medtronic staff. The annual users’ meetings
and international special events offer the perfect platforms for sharing and
exchanging experiences. The Medtronic experts are also happy to assist you as
needed–during clinical application in the operating theatre.
The O-arm in numbers:
• 700+ O-arm global installations
• 150+ O-arm installations in Europe
• 250,000+ Patients bene ted from O-arm use
• 1,500+ Surgeon user worldwide use.
Source: Medtronic
With the depth and breadth of our expertise and technologies, we offer
integrated procedural solutions that can help support your goals of:
Advancing patient care.
Performing faster, more precise procedures.
Reducing patient complications and improving clinical outcomes.
Achieving better economic value.
Enabling more minimally invasive and complex procedures.
03.03.2015
Advanced technology
#3D #company #manufacturers #medical technology #MRT #Radbook #radiology #scanner #work ow
R/F Digital
Volume CT
#3D #4D #CT #detection #medical technology #Radbook #radiation protection #radiology #scanner
Related products
ACCESSORIES / COMPLEMENTARY SYSTEMS Interventional Systems - Surgical Flat Panel C-Arm
Specialties Specialties
General
LabBook
RadBook
Manufacturer-Index
Media Kits
Newsletter
Contact
Facebook
Twitter
YouTube
RSS-Feed
Disclaimer
Imprint