AlarmClear
Clears an acknowledged (and off) alarm from the active alarm list. You can clear the alarm
where the cursor is positioned, one or more alarm lists on the active page, a whole
category of alarms, or alarms of a particular priority.
If you set the [Alarm]AckHold parameter to 1, alarms that go off and have been
acknowledged are not removed from the active list until this function is called.

Syntax
AlarmClear(Mode, Value [, ClusterName] )
Mode:

The type of clear:


0 - Clear a single alarm where the cursor is positioned:
Set Value to 0 (zero) - it is not used.
1 - Clear a page of alarms. AN alarm page can contain more than one alarm list:
Set Value to the AN where the alarm list is displayed.
Set Value to 0 to clear the (displayed) alarm list (on the active page) where
the cursor is positioned.
Set Value to -1 to clear every (displayed) alarm list on the active page.
2 - Clear a category of alarms:
Set Value to the alarm category (0 to 16375) of the alarms to clear. Please be
aware that alarm category 0 indicates all categories; alarm category 255
indicates hardware alarms.
Set Value to the group number to clear a group of categories.
3 - Clear alarms of a specific priority.
Set Value to the alarm priority (0-255) of the alarms to be cleared.
Alarm priority 0 indicates all priorities. Hardware alarms are not
affected by priority. Set Value to the group handle to clear a group of
alarms of different priorities.
Value:

Used with Mode 1 or 2 to specify which alarms to clear.

ClusterName:

Used with Mode 2 or 3 to specify the name of the cluster in which the alarms being cleared reside.
This argument is optional if the client is connected to only one cluster containing an Alarm Server or
you are resolving the alarm server via the current cluster context.

This argument is not required where:


the mode is 2 and the value is 255 (hardware alarm category).

This argument is enclosed in quotation marks "".

Return Value
0 (zero) if successful, otherwise an error is returned.

Related Functions
AlarmAck

mk:@MSITStore:C:\Program%20Files\Schneider%20Electric\Vijeo%20Citect%207.2... 3/10/2014
AlarmClear Page 2 of 2

Example

System Keyboard

Key Sequence Clear

Command AlarmClear(0, 0)

Comment Clear the alarm where the cursor is positioned

System Keyboard

Key Sequence ClearAll

Command AlarmClear(1, -1)

Comment Clear a page of alarms

System Keyboard

Key Sequence AlarmClear ### Enter

Command AlarmClear(2, Arg1, "clusterXYZ")

Comment Clear alarms of a specified category in cluster XYZ

System Keyboard

Key Sequence CtrlClear

Command AlarmClear(2, 0, "clusterXYZ")

Comment Clear categories of inactive alarms in cluster XYZ

System Keyboard

Key Sequence ClearPri ########### Enter

Command AlarmClear(3,Arg1, "clusterXYZ")

Comment Clear alarms of a specific priority in cluster XYZ