Bag Filters

Cyclone cum Bag Filters

For

Flue Gas Particulate Pollution Control


De dusting systems
Product recovery in Dryers/Coolers

ECOKLEEN POLLUTION CONTROL PVT. LTD.


Pushpa Heights, 1 st Floor, Bibwewadi Corner, Pune – 411 037.India
Tel: +91-20-64005334, 65240946 ,24212390 Fax: +91 -20-24210128
E-mail: mktg@ecokleen.com Web: www.ecokleen.com
About Transparent Group of Companies:

The Group has been promoted in 1986 and has been active in the
area of engineering and technology, the head offices being in
Pune, India. The group has grown by leaps and bounds with several
innovative and path breaking technological solutions in India as
well as countries like Germany, Saudi Arabia, Indonesia, Malaysia,
China, Egypt etc.

The Group focuses on several key engineering sectors, undertaking


contracts from concept to commissioning of various equipment for
Waste Heat Recovery, AARP, Boilers and Heaters, Flash Dryers,
Spray Dryers, Multi Stage Evaporation Plants, Heat Exchangers, Hot
Air Generators, Emission and Pollution Control and Flue Gas
Desulphurization Plants. Sound Abatement and Noise Pollution
control systems.

The Transparent Group of Companies has the following companies


with in the GROUP.

1. Transparent Energy Systems Pvt Ltd www.tespl.com


2. Transparent Technologies Pvt Ltd www.ttplpune.com
3. Ecokleen Pollution Control Pvt Ltd www.ecokleen.com
4. Decimin Control Systems Pvt Ltd www.decimin.com

The group employs skilled and experienced engineering staff and


has more than 200 Engineers in various disciplines. The group has
three manufacturing locations, well equipped with plant and
machinery to supply equipment of high sophistication and
performance.

Group Companies have technology tie ups for some of the prod ucts
with the best names in the relevant products such as Mattes
Engineering GmbH of Germany for Ammonia Absorption
Refrigeration Plants and IAC BOET STOPSON of France for Acoustic
Canopies for DG Sets, Compressors, Machinery, Noise Silencers for
Engines, Blowers, Compressors, Valve exhaust, Acoustic Louvers &
Baffles and with Lamont – Kassel GmbH and Co KG of Germany for
High pressure Steam Boilers , Hot Water Boilers and Thermic Fluid
Heaters in India and globally.
Conventional (Counter current) Vs Ecokleen (Co
current) Bag Filters

Recovery of particulate matter from exhaust gas is vital for any


industry and in many instances a bag filter is deployed to
separate fine particles from air/gas .to recover, finished product
and /or to limit the particulate pollution of flue gases emitting
from the plant.

A conventional bag filter in most of the cases employ the Counter


Current principle for filtration.

In a Counter current principle of filtration, as conventionally


carried out, due to the bottom entry of the dirty flue gas, the
already filtered particles which are dropping down due to the
pulsing action, again partly get entrained in the incoming flue gas,
there by increasing the dust loads for filtration and limit the
efficiency of filtration due to the limiting ‘ Can velocity’

As a result of this several problems are encountered leading to


unstable operation and
Unplanned shutdowns as a result of the following causes.

F Frequent bag chocking - hence high plant shut down time.

F Higher pressure drops across bag filter – hence higher


blower electrical power.

F Bag chocking, resulting in reduced flow & therefore


reduction in plant capacity.
Counter Current (Conventional) Vs Co current
(Ecokleen) Filtration

Conventiona l - Counter current Ecokleen – Co current

The above illustration furnishes the comparison between the two


principles of filtration and It can be well imagined that, for any
given filtration area provided, the Counter current filter is bound
to suffer for more dust loads due to the entrainment of the
already filtered particles, hence leading to the re entrainment and
chocking problems.
Ecokleen have overcome these short falls by unique design of
gas/powder co current flow pattern and using advanced modelling
procedure for design of bag filter

» Ecokleen bag filters are co-current gas flow (Indian patent


awarded). Here in the air/gas and dust to be separated flows in
downward direction in bag house chamber as depicted in the
illustration above

» The co-current flow avoids entrainment of dust in air/gas


avoiding bag chocking, higher-pressure drops leading to
reduced plant capacity, unstable operation and shutdowns.
It has been thus proved that due to this COCURRENT filtration
principle Ecokleen Bag filters works with lower pressure drops
leading to a stable operation. It has been observed from several
field operations that the pressure drop never exceeds 100 mm WC.
Ecokleen Cyclone cum Bag Filter

» Conventionally cyclone is installed as primary separating device


followed by bag filter as the final separation devise.

» Such an arrangement i.e. a cyclone followed by bag filter has


following disadvantages

F Pressure drop is more (cyclone plus bag filter) thus fan


power required is more thus, energy bills are more.
F Space required is more – increasing civil and structural cost.
F Two point collection system – needs two separate packaging
areas (more man power), or additional equipments (screw
conveyor) to make it single point collection (more energy
bill).
Realising the above, Ecokleen has developed cyclone cum bag
filter, which uses the patented Co current filtration technology
clubbed with the cyclone design.

Such an arrangement as compared to the two stage particulate


separation, has lower pressure drop, requires less space, and has
single point collection.

Working Principle of Ecokleen Bag Filter and Cyclone


cum Bag Filter

Working principle of Ecokleen co current design Bag filters


And Cyclo ne cum bag filter.

The dust-laden air enters in to the cyclone chamber,

1. The powder separates due to cyclonic action and then enters


into the bag filter chamber.
2. Air is uniformly distributed avoiding channelling while the
powder separated by cyclone slides down from sides.
3. Initially a coat of material forms on the bags. Subsequently,
the coat acts as the filtering medium.
4. The dust accumulated on filter elements while the air passes
through the filter bags from outside to inside.
5. The accumulated powder dislodged from the bags by reverse
pulsejet air intermittently.
6. The dislodged powder falls on bottom cone and it discharges
through powder discharge valves.
7. The dust free air is suck by induced draft fan and is
exhausted to atmosphere.
8. Knockers provided on conical portion especially for
sticky/hygroscopic materials.
Main components of Ecokleen Bag Filter and Cyclone
cum Bag Filter

1. Air entry Cyclone chamber and Bag filter housing:

» All the components of the Bag filter-housing casing are


designed individually considering the application. Ample safety
factors are provided for bursting strength of the casing.
Adequate stiffening is provided for mechanical strength.
» Materials of construction are chosen accordin g to the nature of
the flue gas, temperature and corrosive behaviour.
» The design of the hoppers is carried out with adequate valley
angles depending on the material characteristics.
» Air entry Bustle type construction ensures uniform distribution
of air at the entry there by ensuring no chocking.
» A most important feature for maintenance is the ease for bag
replacement. Bag removal is carried from f top, hence
facilitating maintenance, in dust free atmosphere.
2. Filter bags:
• We carefully select filter bag fabric considering temperature,
particulate size, air-to- cloth ratio, and properties of material to
be separated and the particulate emission guarantees.

• The Felt media bag minimizes pressure fluctuations giving


uniform and high collection efficiency.

• Specially selected Anti-stick coating on bags minimizes bag


chocking.

3. Bag cages:

• The cage forms the most important support member for


ensuring long life of the Bags. Ecokleen Bag filters invariably
have Cages made out of larger diameter bars to make the
assembly rigid an often-overlooked aspect by many other
manufacturers.

• The pitch between bars kept providing adequate support by


cages. This avoids flex line failure between the vertical wires.

• Careful selection of fit between cage and bag avoid premature


bag failure.

• If bag is oversized then bags may have internal abrasion along


vertical lines causing bag failure.
• Sharp edges on Pan are avoided as they cut / damage the bag
where it comes in contact, with the edge of Pan.

4. Cage, Ventury assembly:

• Higher thickness ventury mounting plate – uniform pressure is


applied - seals better.

• Ventury are cast –rigidity in clamping reducing leakages.

• Special Silicone gasket ensures Leak-proof joint between ventury


and ventury mounting plate.

• Clamps provided to hold the bags on cages and seal for


leakages. Clamps are always made from Stainless Steel to
prevent bag damage.

Robust Positive Clamping Assembly of Venturys ensures no


slippage of the
Assembly and no loosening leading to a stable
performance

Assembly of Cage Ventury Die cast and machined ventury


And Clamp
4. Pulse Jet system, with Isolation Valves:

• Under normal running condition, the process air enters the filter
bags and is exhausted above ventury mounting plate.
• The bag filter cleaned on -line by compressed air pulses given
periodically by a timer circuit. The duration of pulse time and its
frequency can adjust.
• While on-line cleaning of bags, compressed air pulse injected
in to the ventury by solenoid valve.
• The bag inflates and dust accumulated on its outer surface gets
dislodged and removed. One row of bags cleaned at a time.

Pulse Jet system

5 Shop testing and Assembly:

F Airflow rate,
F Pressure drop at no dusting,
F Workmanship

Bag Filter casing under Shop Test


Bag Filter with Bleed air arrangement at site
How Ecokleen Bag Filter and Cyclone cum Bag Filter
pays for itself?

Ecokleen Bag Filter:

» The pressure drop across Ecokleen Bag Filter is 100 mm WC while


that of conventional Bag Filter is 150 mm WC.
» Thus, Ecokleen reduces the load on fan by 50 mm WC.
» Table below gives the power savings for different airflow rates.

Sr. Gas flow Power saved Power saved Savings


3
rate (m /hr) per hour per annum per annum
(kWh) (kWh) (Rs)
1. 1,000 0.21 1,680 6,972/-
2. 5,000 1.05 8,400 34,860/-
3. 10,000 2.10 16,800 69,720/-
4. 15,000 3.15 25,200 1,04,580/-
5. 20,000 4.20 33,600 1,39,440/-
Note:
» Working hours per year considered is 8000
» Electricity tariff rate considered is 4.15 Rs/kWh

Ecokleen Cyclone cum Bag Filter:

» The total pressure drop across Ecokleen cyclone cum bag filter
is typically 125 mm WC.
» The total pressure drop across conventional cyclone is 100 mm
WC and across bag filter is 150 mm WC – totalling to 250 mm WC.
» Thus, Ecokleen reduces the load on fan by 125 mm WC.
» Table below gives the power savings for different airflow rates.

Sr. Gas flow Power saved Power saved Savings


rate per hour per annum per
(m3/hr) (kWh) (kWh) annum
(Rs)
6. 1,000 0.52 4,192 17,398/-
7. 5,000 2.60 20,800 86,320/-
8. 10,000 5.20 41,920 1,73,980/-
9. 15,000 7.80 62,400 2,58,960/-
10. 20,000 10.40 83,840 3,47,936/-
Note:
» Working hours per year considered is 8000
» Electricity tariff rate considered is 4.15 Rs/kWh
Optional Extras:

Air bleeding arrangement

• A temperature monitored automatic “Air bleeding’’ arrangement


avoids exposure of bags to higher temperatures and ensures
longer bag life.
• The temperature of air entering bag house sensed. If the
temperature of air increases above set limit, pneumatically
actuated damper opens and fresh air sucked in and mixes with
process air lowering its temperature. A Manual damper is also
provided when automatic damper is under maintenance

Applications of Bag Filters Installed :

Iron Ore Pellet Plant : dedusting systems , Product collection


from Rotary Dryer
Boiler Flue Gas cleaning
Spray Drier and Flash Dryers for Paints and Pigments
Flash Dryers for Agrochemicals
Metal (Lead) Melting Plants and Pollution control there of.

For Further information contact:

Ecokleen Pollution Control Pvt. Ltd.


’Pushpa Heights’ Ground Floor,
Bibvewadi corner,
Pune – 411037 , INDIA
Tel : +91 20 64005334, 65240946
Fax : 020 24210128
E Mail : mktg@ecokleen.com
Web: www.ecokleen.com