Beruflich Dokumente
Kultur Dokumente
Series 05
Model 05-QC
Model 05-C
Model 05H-M1
Features
May be installed in concealed locations without access panels. They are factory air charged and are not rechargeable. May be installed in new or existing plumbing systems vertically, horizontally or at any angle.
Model 05-C-T Model 05-CXT Model 05-PEX-T
Pressure Temperature
Operating Pressure Designed especially for use in light commercial or residential applications on lines up to 150psi (10.6 bar) working pressure. Temperature Range 33F to 180F (0.5C - 82C) Air Preload 60psi (4.2 bar)
Models
05 For NPT threaded applications. 05-QC Arrestor offered with Quick-Connect Tee. 05-C For installation on 12" CTS for new or retrofit applications. 05H-M1 For in-line use with washing machines. 05-C-T For either 14" icemaker or 38" lav supply tube installation. 05-CXT For installation directly on supply stop either between stub out and stop or between stop and supply tube. 05-PEX-T For either 38" or 12" in-line PEX installation.
See reverse side for complete list of models.
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Standards
Meets requirements of ASSE Standard 1010 and listed by IAPMO.
Fig. 1
Watts 05
1010
Fig. 2
Watts 05
Installations
Watts Series 05 water hammer arrestors should always be installed as close to the source of shock as possible - one unit on each hot and cold water line. Although they function in any orientation, Figure 1, 2 and 3 show the proper installation where the shock would be absorbed most effectively.
shock source
shock source
Watts 05
Dimensions - Weight
Straight Models
Model Size (DN) in Connection Type A mm in mm in dimension B mm lbs kgs Weight
12 12 34 34 12 34 58
38
10 15 15 20 20 15 20 16
32 32 29 50 81 25 25 32
Tee Models
Model Size (DN) in Connection Type A mm in mm in dimension weight B mm lbs kgs
38 58 38 12
14 38
8 10 10 16 10 15
OD Comp. OD Comp. OD Comp. x Reverse Comp. Nut OD Comp. x Reverse Comp. Nut PEX PEX
70 77 72 78 58 58
Quick-Connect
Model Size (DN) in
12 34
Connection Type A in
dimension B mm in mm
mm
05-QC 05-QC
15 20
Quick-Connect Quick-Connect
3 3332
58
93 104
7 934
38
187 247
.4 .57
.18 .26
A
USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca
ES-05 1012
2010 Watts