Section 1700
iii) Excessive entrainment of large air bubbles,
iv) Unusually rapid stiffening of concrete,
v) Rapid loss of slump
vi) Excessive segregation and bleeding.
1705.2 Mineral Admixtures
For use of mineral admixtures, refer Clauses 1714.1 and 1715.2.
1706 SIZE OF COARSE AGGREGATES
The size (maximum nominal) of coarse aggregates for concrete to be used in various,
components shall be as given in Table 1700-7.
Table 1700-7 : Maximum Nominal Size of Coarse Aggregates
Structural Concrete
Components
Maximum Nominal Size
of Coarse Aggregate
(rm)
1) RCC well curb 20
ii) _RCC/PCC well steining 40
ii) _ Well cap or Pile Cap Solid type piers and abutments 40
iv) RCC work in girder, slabs wearing coat, kerb, approach 20
slab, hollow piers and abutments, pier/abutment caps,
piles
lv) _PSC Work 20
vi) Any other item
[As specified by the
Engineer
Maximum nominal size of aggregates shall also be restricted t
values :
a) 10 mmiess than the minimum lateral clear distance between individual
reinforcements
b) 10 mm less than the minimum clear cover
c) One quarter of minimum thickness of member
The proportions of the various individual sizes of aggregates
grading produces the densest mix and the grading curve corresponds to the m
nominal size adopted for the concrete mix.
(0 the smaller of the
to the reinforcement
shall be so a
following. =
.djusted that the
vaximut