Sie sind auf Seite 1von 6

S V S P R O T E C T 1. 1 1 A N D 1 .

3 1

THE HIGH-PERFORMANCE ONLINE


UPS SYSTEM FOR THE IT/EDP SECTOR

Plug
and
Save ➜ ➜ ➜
S V S P R O T E C T 1. 1 1 A N D 1 . 3 1

R O B U S T A N D S I M P LY S A F E

The SVS Protect 1. provides the IT/EDP sector with a high- Key feature
performance, robust and easy to use online UPS unit which ➜ It can take a lot
also demonstrates convincing economic arguments. Compared to the UPS market stan-
dard as laid down in the UPS prod-
uct standard EN 50091, the SVS
Additional protection level against Protect 1. is 2 to 3 times more robust
EMC influences for SVS Protect 1. ESD
against interference such as high-
Electrostatic
discharge
energy surges on power lines, high-
speed overvoltages on power and
HF fields
signal lines (burst) and electrostatic
Surge
Surge Emitted
voltages resistance

tandrd
Product-sn0d9a -2
uc t
N-s50 1
ta
Prod E
EN 50
091-2 el
S- Lev 2
EG SV 81 -
00
Additional Andard EN 5
to generic sta
Burst
High-speed
transients

➜ It can take a lot

A significant factor for process secu- the IT sector, these can lead to lost
rity in the IT sector is an uninterrupti- data, system crashes as well as per-
ble power supply. Although the avai- manent hardware and software
lability of the European grid is exem- damage. Generally speaking, such
plary at 99.98 %, it is still possible losses and damage entail considera-
that there are about 150 intermittent ble financial costs and are bad for
power outages detectable per annum the image of the company concer-
in a local power system. Furthermore, ned. discharges (ESD). This UPS is also
there can be high voltage peak sur- 3 times more resistant against HF
ges, voltage and frequency fluctu- The SVS Protect 1. with its power- field emissions than standard units.
ations, distorted voltage waveforms level from 4.5 to 10 kVA protects
and even complete power cuts. In your networks against all faults The SVS Protect 1. operates accord-
in the electrical power supply, ing to the double converter principle
offering a reliable safeguard, and is designed for use in surge
whether in the office or in harsh protection zone 3 as standard.
industrial conditions. However, it can be upgraded with
specially adapted safety modules to
offer proven service in surge protec-
tion zones 1 and 2.

Foto: IBM
Key feature Total Network Security Economic advantages
➜ Plug and save The SVS Protect 1. is capable of con- The SVS Protect 1. is inexpensive to
The SVS Protect 1. is a Plug - trolling a TCP/IP network fully auto- purchase and offers pleasingly low
and - Save - Unit for rapid and matically in conjunction with the operating costs thanks to its excellent
easy connection. "CompuWatch" network software efficiency levels of up to 98 %.
These low-noise units are fitted with developed by AEG SVS. It can also
rollers so they can be accommoda- do this for heterogeneous networks – This permits up to DM 400 to be
ted in any office without difficulty. a unique feature setting it apart from saved year in, year out in every day
The display has a functional layout others in its class. online use.*
and shows current data at a glance.
The connected network can be Its careful battery management func-
shut down and rebooted according tion produces additional benefits with
to calendar entries or whenever regard to economy. SVS Protect 1.
required. Naturally, individual work- always knows the exact charge level
stations can be controlled in this of its batteries and only ever supplies
way as well. the amount of charging
current which is actually required.
With SVS Protect 1. and Compu- Such an operating method means
Watch, you get a complete security the batteries can last two or three
solution for networks and individual years longer before replacement
workplaces (total network security than with standard systems. This re-
solution) from one company. sults in additional benefits.

Total Network Security Solution


All functions can be controlled using
only a few keys. The keys themselves
can be electronically locked in order
to prevent any inadvertent change
of operating mode.
SVS Protect 1.

Sun Solaris
Win NT
SCO Unix

HP- UX IBM AIX Novell Netware Sinix

* Assuming an electricity price of DM 0.20/kWh and 80 % load of the SVS Protect 1.


with 10 kVA rated power
Y O U R A D VA N TA G E S

➜ Suitable for offices and harsh


industrial environments

➜ More robust than the UPS standard


by a factor of 2 to 3

➜ Can be upgraded for surge


voltage protection zones 1 and 2

➜ Protected against overload

➜ Plug and Save

➜ Ergonomic display for ease


of operation

➜ Maximum efficiency

➜ Inexpensive to purchase and


operate

➜ Economy mode can be selected

➜ Total service offers for retention


of value

➜ Communications - capable
via SNMP

➜ Reliable shutdown and reboot


using AEG SVS network software
CompuWatch

➜ Compact in size, modern design

➜ 40 years’ experience with


UPS units

➜ - compliant
Service Perfect
Taking the important decision in
favour of the SVS Protect 1. UPS
system provides you with the univer-
sal solution for your network security.
To make sure things stay that way,
we offer equally high quality service
support after you have bought this
online UPS system. Assistance is
available round the clock.

When you purchase the SVS Protect 1.,


you can decide to choose one of our
service packages which are tailor -
made to meet your requirements:
“Service Perfect“ or
“Service Perfect Plus“.
If required, both service packages
can include the commissioning of
your UPS system by one of our
service engineers who always check
how the unit is linked up to your
installations as well.

Find out which service package suits


you.
Call our service hotline:
+ 49 - (0) 29 02 / 763 -100

Incidentally: When you buy an SVS


Protect 1., we will of course be hap-
py to dispose of any old UPS systems
from our company which you are
taking out of service.

➜➜➜
S V S P R O T E C T 1. 1 1 A N D 1 . 3 1

T E C H N I C A L D ATA

TYPE SVS Protect 1. SVS Protect 1. SVS Protect 1. SVS Protect 1. SVS Protect 1.
045/11 060/11 060/31 075/31 100/31
Type power at cos  = 0.7 lag (kVA) 4.5 6.0 6.0 7.5 10.0
RECTIFIER UNIT
Rated connected voltage 230 V; opt. 220; 240 V +10% – 25% 400 V/230 V +15 % - 25 %
Frequency 50/60 Hz ± 10 % (automatic frequency setting)
Current consumption at full-load (A) 17.0 ( 1ph~) 22.0 ( 1ph~) 10.0 ( 3 ph~) 12.0 ( 3 ph~) 15.0 ( 3 ph~)
System perturbation Load-factor > 0.98 > 0.98 > 0.95 > 0.95 > 0.95
(low system perturbation)
Characteristics I U to DIN 41773
Inrush current ≤ Irated (soft-start)

INVERTER UNIT
Rated DC voltage (DC link) (V) 192 264 264 336 432
Rated AC voltage (single-phase) 230 V ± 2 %
Dynamic response In load cycle 0 -100 % - 0, voltage dip < ± 5 %
Frequency tolerance without mains control 50 Hz ± 0.1 %, optional 60 Hz ± 0.1 %
Frequency tolerance (synchronisation range) 50 Hz ± 4 %, optional 60 Hz ± 4 %
Load-factor range capacitive to inductive over the entire cos  -range
Output current (A) 19.5 26.0 26.0 32.6 43.4
Voltage form sinusoidal
Voltage factor distortion ≤ 3 % over the total load and power factor range
Crest factor for non-linear load 3
Non-linear load up to 100 % of the UPS nominal load
Overload response overload capacity 125 % for 2 minutes, 150 % for 30 s, 200 % for 100 ms

ELECTRONIC SWITCHOVER UNIT


(integrated) Static Bypass Switch(SBS), manual bypass

GENERAL DATA
Efficiency total, economy mode 98 %
Efficiency total, online mode > 92 % > 92 % > 92 % > 92,5 % > 93 %
Noise level in economy mode ≤ 40 dB (A)
Noise level in online mode ≤ 48 dB (A)
EMC emitted interference to EN 50081 - 1
EMC strength to EN 50082 - 2
Operating temperature range 0° C to + 40 ° C (max. cooling air temperature + 35 ° C)
Storage temperature range – 15 ° C to + 50 ° C
Type of cooling Reinforced air natural cooling in online range via variable speed axial fan (load-dependent)
Installation height up to 1000 m above sea level at nominal load
Equipment colour RAL 7044
902/0800 EN Printed in Germany · right to modification reserved · VHMA · Wiesbaden
Protective system IP 21 to DIN 40050
Size w x h x d (mm)
– 10 min. bridging time at nominal load 200 x 700 x 680 200 x 700 x 680 400 x 700 x 680 400 x 700 x 680 400 x 700 x 680
– 25 min. bridging time at nominal load 400 x 700 x 680 400 x 700 x 680 400 x 700 x 680 600 x 700 x 680 600 x 700 x 680
– 50 min. bridging time at nominal load 400 x 700 x 680 400 x 700 x 680 600 x 700 x 680 800 x 700 x 680 800 x 700 x 680
Weight incl. battery system (kg)
– 10 min. bridging time 75 90 120 135 160
– 25 min. bridging time 135 170 180 235 280
– 50 min. bridging time 180 230 260 335 400
Battery integrated, sealed lead-acid battery
1. RS 232 serial interface Subminiature, 9 - pin (e.g. PC connection)
2. Interface potential-free contacts Subminiature, 25 - pin (e.g. remote signalling)
Communications software CompuWatch (optional)

AEG SVS
Power Supply Systems GmbH
A company of Saft S.A.
Emil-Siepmann-Straße 32
D -59581 Warstein - Belecke
Phone +49(0)29 02/7 63 -1 45
Fax +49(0)29 02/7 63 -7 24
http ://www.aegsvs.de

I n t e r n e t : h t t p : // w w w. s a f t . a l c a t e l . c o m

Das könnte Ihnen auch gefallen