Beruflich Dokumente
Kultur Dokumente
Product Description
www.huawei.com
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page1
References
BSC6000 Hardware Description
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page2
Objectives
Upon completion of this course, you will be able to:
Understand BSC6000 function and features
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page3
Contents
1. System Description
2. Hardware Structure
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page4
Location of the BSC6000
The HUAWEI BSC6000 is a new generation GSM BSC
MS: mobile system, celular
Abis PDN
Um
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page5
BSC6000 Version Evolution
V9R8C01
V9R3C001
V9R1C03
V9R1C01
R1 R3 R8
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page6
Large capacity High integration
Supporting 2048TRX at the full rate; supporting 2048TRX
at the half rate and 15360 speech channels.
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page7
Large capacity High integration
GTCS.- GSM Transcoder subrack
BM/TC combined,1 cabinet support 2048TRX
2048TRX
BM+TC
+ 2048TRX
BM TC
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page8
Built-in PCU, Advanced PS Performance
14 15 16 17 18 19 20 21 22 23 24 25 26 27
PCU6000 G G G G G G G G G G
O O O O E E E E E E BSC6000
I I I I P P GOMU GOMU I I I I
U U U U U U U U U U
A A A A G G B B B B
G G G G G G G G
G G G G G G
X X X X D D D D
T T S S G G
P P P P P P P P
N N C C C C
U U U U U U U U
U U U U U U
M M T T P X X X
GOIUA: GSM Optic interface for A 0 1 2 3 4 5 6 7 8 9 10 11 12 13
One GDPUP (GSM Data Processing Unit for PS) supply 1024 MCS-9
active PDCH processing,BSC6000 support 8192 MCS-9 active
PDCH at most, Support 512M Gb throughput at most
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page9
Support BSS Over IP
G
IP route transmitting F Support 6144 voice circuits;
F protocol function G
G Support A interface over IP
8FE ports or 2GE ports U
2 Support IP over A (Fast ethernet and Gigabit
a FE/GE/IWF A Interface ethernet )
G
O Support 6144 voice circuits
Over IP G
Support A interface over IP
U
G A (Optic Gigabit ethernet)
IP route transmitting
O protocol function
U
Supply 2 optical ports G
a 384TRX,100% Half Rate
Support IP over GE F
G Supply Abis interface by
U
Abis FE/GE (Fast ethernet and
B
GFGUB: GSM Fast ethernet Gigabit ethernet )
and Gigabit ethernet Unit for Interface G 384TRX,100% Half Rate
O
aBis G Supply Abis interface by
Over IP
GOGUB: GSM OpticalUnit for U GE (Optic Gigabit
B
aBis ethernet)
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page10
Support Abis over HDLC
HDLC High-Level Data Link Control
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page11
Flexible configuration
Multiple networking modes
Based on E1/T1 or STM-1 networking, the BSC6000 and the BTSs
can use the star, chain, and tree networking modes
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page12
Features of the BSC6000 System
Strong performance, advanced design
Supporting 2M signaling link
MML function
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page13
Contents
2. Hardware Structure
2.1 Rack
2.2 Subrack
2.3 Board
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page14
Structure of Rack
Model: Huawei N68-22 cabinet
Dimension: 600mm (width) x800mm (depth)
x 2200mm (height)
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page15
GBCR
The GBAM and GOMU are the operation Power
distribution box
and maintenance entities of the BSC.
Cabling
There are two types of BSC hardware subrack
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page16
GBSR
GBSR (GSM BSC Service
Processing Rack ): It is only
configured with service subracks Subrack
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page17
Fan Box
PFCU (Fan Control Unit)
Monitors the running status of the fans in the fan box
Shows the current status of fan box and alarms through LED
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page18
Power Distribution Box
Checks two channels of - 48 V input voltage
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page19
Subrack
Fan box
The width of subrack is 19
Board
inches
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page20
Subrack Type
The BSC subracks can be classified into the following
types:
GMPS--GSM Main Processing Subrack
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page21
Configuration Modes of Subracks
The BSC subracks support the following configuration
modes:
BM/TC separated-- In BM/TC separated configuration mode, the
BSC consists of the GMPS/GEPS and GTCS. The GTCS can be
configured on the BSC side or on the MSC side based on the OM
path between the GMPS and the GTCS
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page22
Type of PCU
There are two types of PCU: built-in PCU and
external PCU
The external PCU is an independent network element that
provides PS service processing functions. It communicates
with the BSC over the Pb interface, and communicates with
the SGSN over the Gb interface
The built-in PCU is the GDPUP, which provides PS service
processing functions. The GDPUP is configured in the
GMPS/GEPS
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page23
Example
BM TC
Cb
CBC LMT
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page24
Subrack——GMPS
The GMPS processes the basic services and performs the
O&M function. In addition, the GMPS provides clock for
the system
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page25
Subrack——GMPS(BM/TC separated)
When non-IP boards are used on the A interface, the fully
configured GMPS is shown in the below
14 15 16 17 18 19 20 21 22 23 24 25 26 27
G G G G G G G G G G
Rear E E E E E E E E
O O
I I P P M I I I I
M
U U U U U U U U
U U
T T G G B B B B
board
Front G G G G G G G G G G
G G
board X X X X T T S S D D G G
P P P P N N C C P P C C
U Backplane
U U U U U U U U U U U
M M T T P P
00 01 02 03 04 05 06 07 08 09 10 11 12 13
In BM/TC separated (built-in PCU) configuration mode, the GMPS must be configured with
the GTNU, GSCU, GGCU, GXPUM, GDPUP, and GEPUG. The GDPUX, GXPUT,
GEIUB/GOIUB/GEHUB/GFGUB/GOGUB, and GEIUT/GOIUT are optional boards.
When the number of TRXs to be supported is greater than 256, a pair of GXPUTs must be
configured in the GMPS.
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page26
GTCS
The GTCS implements the transcoding, rate adaptation,
and sub-multiplexing functions
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page27
GTCS-E1 Transmission
When the BSC6000 uses E1 transmissions on the A
interface, a GTCS provides a maximum of 3,840 speech
channels
14 15 16 17 18 19 20 21 22 23 24 25 26 27
G G G G G G G G G G
Rear E E E E E E E E E E
board I I I I I I I I I I
U U U U U U U U U U
T T A A A A A A A A
Backplane
G G G G G G G G
T T S S D D D D
Front N N C C P P P P
board U U U U U U U U
X X X X
00 01 02 03 04 05 06 07 08 09 10 11 12 13
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page28
GTCS-Optical Transmission
When the BSC6000 uses STM-1 transmissions on the A
interface, a GTCS provides a maximum of 7,680 speech
channels
14 15 16 17 18 19 20 21 22 23 24 25 26 27
G G G G G G G G G G
Rear O O O O O O O O O O
board I I I I I I I I I I
U U U U U U U U U U
T T A A A A A A A A
Backplane
G G G G G G G G G G G G
D D T T S S D D D D D D
Front P P N N C C P P P P P P
board U U U U U U U U U U U U
X X X X X X X X
00 01 02 03 04 05 06 07 08 09 10 11 12 13
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page29
Subrack——GMPS(BM/TC combined)
+ =
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page30
Subrack——GMPS(BM/TC combined)
When non-IP boards are used on the A interface, the fully
configured GMPS is shown in the below
14 15 16 17 18 19 20 21 22 23 24 25 26 27
G G G G G G G G G G G G
Rear O O O O E E E E E E
O O
board I I I I P P I I I I
M M
U U U U U U U U U U U U
A A A A G G B B B B
Backplane
G G G G G G G G G G G G G G
X X X X T T S S D D D D G G
Front P P P P N N C C P P P P C C
board U U U U U U U U U U U U U U
M M T T P P X X
00 01 02 03 04 05 06 07 08 09 10 11 12 13
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page31
Subrack——GEPS
The GEPS processes services for the BSC. The BSC6000 is
configured with 0–2 GEPSs in the GBCR or the GBSR
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page32
Subrack——GEPS(BM/TC separated)
14 15 16 17 18 19 20 21 22 23 24 25 26 27
G G
E
G G G G G G
Rear E
I I E E E E E E
board
U U I I I I I I
T T U U U U U U
B B B B B B
Backplane
G G G G G G G G G G G
X X X X T T S S D D D
Front P P P
P P P P N N C C
board U U U
U U U U U U U U
M M T T P P P
00 01 02 03 04 05 06 07 08 09 10 11 12 13
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page33
Subrack——GEPS(BM/TC combined)
When non-IP boards are used on the A interface, full
GEPS configuration is shown in the below
14 15 16 17 18 19 20 21 22 23 24 25 26 27
G G G G G G G G G G G G G G
Rear O O O O O O E E E E E E D D
board I I I I I I I I I I I I P P
U U U U U U U U U U U U U U
A A A A A A B B B B B B X X
Backplane
G G G G G G G G G G G G G G
X X X X T T S S D D D D D D
Front P P P P P
P P P P N N C C P
board U U U U U U U U U U U
U U U
M M T T P P P X X X
00 01 02 03 04 05 06 07 08 09 10 11 12 13
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page34
Abbreviation
Abbreviation Full Name
GGCU GSM General Clock Unit
GSCU GSM Switching and Control Unit
GTNU GSM TDM switching Network Unit
GXPUM GSM eXtensible Processing Unit for Main service
GXPUT GSM eXtensible Processing Unit for Transmission
GEIUB GSM E1/T1 Interface Unit for Abis
GEIUP GSM E1/T1 Interface Unit for Pb
GEIUT GSM E1/T1 Interface Unit for aTer
GEIUA GSM E1/T1 Interface Unit for A
GOIUB GSM Optic Interface Unit for Abis
GOIUP GSM Optic Interface Unit for Pb
GOIUT GSM Optic Interface Unit for aTer
GOIUA GSM Optic Interface Unit for A
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page35
Abbreviation
Abbreviation Full Name
GOMU GSM Operation & Maintenance Unit
GDPUC GSM Data Processing Unit for CS service
GDPUP GSM Data Processing Unit for PS service
GDPUX GSM Data Processing Unit for eXtensible service
GFGUA GSM Fast ethernet and Gigabit ethernet Unit for A
GFGUB GSM Fast ethernet and Gigabit ethernet Unit for Abis
GFGUG GSM Fast ethernet and Gigabit ethernet Unit for Gb
GOGUA GSM Optic Gigabit ethernet Unit for A
GOGUB GSM Optic Gigabit ethernet Unit for Abis
GEHUB GSM E1/T1 High level Data Link Control Unit for Abis
GEPUG GSM E1/T1 Packet Unit for Gb
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page36
Board- GGCU
Configured in slots 12 and 13 in the GMPS (active/standby
mode)
provides synchronous timing signals for the system
Matching
Port Function
Connector
CLKOUT 0-9 Output 8 kHz clock signals to the GSCU RJ45
COM 0-1 Reserved RJ45
TESTOUT Reserved
TESTIN Reserved
CLKIN 0-1 Synchronization clock signal input port, SMB male
used to input one route of external connector
2.048 MHz signal and 2.048 Mbit/s code
stream signals
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page37
Board- GTNU
Configured in slots 4 and slot 5 of the GMPS/GEPS/GTCS
(active/standby mode)
Matching
Port Function
connector
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page38
Board- GSCU
Configured slots 6 and 7 of the GMPS/GEPS/GTCS (active/standby
mode)
Performs maintenance management
Provides a GE platform for the subrack
Provides clock information for the other boards in the same subrack
except the GGCU in the GMPS
Matching
Port Function
Connector
10/100/1000 10/100/1000 Mbit/s Ethernet ports, used to connect
BASE-T 0–9 subracks
10/100/1000 Mbit/s Ethernet ports, used to connect RJ45
10/100/1000
GBAM/GOMU (Only the main subrack is connected with
BASE-T 10–11
the GBAM/GOMU)
COM Debugging port
Clock source port, used to receive the 8 kHz clock
CLKIN
signals from the panel of the GGCU
TESTOUT Clock test signal port, used to output clock test signals SMB male
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page39
Board- GXPUM
Configured in slots 0 and 1 of the Paging control
GMPS/GEPS Voice call control
(active/standby mode). Packet service control
System information management Handover
Channel assignment Power control
BTS common service management
Performs the short message cell broadcast
Matching
Port Function
connector
10/100/1000
GE/FE Ethernet port, reserved RJ45
BASEs- T0-3
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page40
Board- GXPUT
The GXPUT is the transmission processing unit in the
BSC6000. The active GXPUT and standby GXPUT are
inserted in slots 2 and slot 3 in the GMPS or GEPS.
The GXPUT perform LAPD links processing function
of the system
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page41
CPU-XPUa
Board CPU Number Function
CPU0,algorithm,resource management,PS signal
CPU0
processing
GXPUM CPU3 CPUP,PCU maintenance、cell data broadcast
CPU1
CPU2
CPUX ,CS service processing
GXPUT CPU0/1/2/3
14 15 16 17 18 19 20 21 22 23 24 25 26 27
G G G G G G
G G
O O E E E E
O O
I I I I I I
M M
U U U U U U
U U
T T B B B B
Backplane
G G G G
G G G G G
X X X X G
T S S G G
P P P P T
N C C C C
U U U U N
U U U U U
M M T T U
00 01 02 03 04 05 06 07 08 09 10 11 12 13
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page42
Board- GDPUC/X
Indicator Color Status Meaning
On for one second and off for
The board is working normally
one second
On for 0.125 second and off
The board is in loading state
for 0.125 second
On for 2 seconds and off for 2
RUN Green The board is testing
seconds
On There is power supply but the
board is faulty
Off There is no power supply or the
board is faulty
Off No alarm
ALM Red
On (or flashing) The board has a fault alarm
On The board is in active state
ACT Green
Off The board is in standby state
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page43
Board- GDPUP
Configured in slot 8 to slot 11 of GMPS, slot
8 to slot 13 of the GEPS (N+1 redundant
backup mode)
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page44
Board——GOMU
LED Color Status Description
RUN Green On for 1s and off for The board is operating
1s
On for 0.125s and off The board is loading software
for 0.125s
On for 2s and off for The board is being tested
2s
Steady on There is power supply but the board is faulty
Steady off There is no power supply or the board is faulty
ALM Red On (or flashing) There is a fault related to the running board
Steady off There is no alarm
ACT Green Steady on The board works in active mode
Steady off The board works in standby mode
OFFLINE Blue On The board can be removed
Off The board cannot be removed
On for 0.125s and off The status of the board is switching
for 0.125s
HD Green Flashing The hard disk is performing read and write
operations
Steady off The hard disk is not performing read and write
operations
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page45
Board- GEIU/ GOIU
GEIU GOIU GEIU/GOIU works in active/standby mode and can be
categorized into the following types :
RUN RUN
ALM ALM
ACT ACT The GEIUB/GOIUB is the Interface Unit for the Abis interface
The GEIUP/GOIUP is the Interface Unit for the Pb interface
TX
RX The GEIUT/GOIUT is the Interface Unit for the Ater interface
E1/T1(24~31)
Matching
E1/T1(16~23)
Interface Function
connector
The E1/ T1 port,0 ~31 of the used to DB44
E1/ T1
transmit and receive E1/ T1 signals on
E1/T1(8~15)
0-31
routes 0-31
E1/T1(0~7)
2.048 MHz clock source output port, used SMB male
TESTOUT2M1 2M0
TESTOUT2M1 2M0
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page46
Board- GEIU/ GOIU
GEIU GOIU The GEIU/GOIU has the following functions:
RUN RUN
Processes the SS7 MTP2 protocols (performed by GEIUT/GOIUT)
ALM ALM
ACT ACT
Processes the Link Access Procedure on the D channel (LAPD)
TX
protocols (performed by GEIUP/GOIUP or GEIUB/GOIUB )
E1/T1(24~31)
RX
Provides maintenance links when GTCS subracks are configured
at the MSC side
LOS
Matching
Interface Function
connector
E1/T1(8~15)
RX Transmitting optical port 155.52 Mbit/s LC
TX Receiving optical port 155.52 Mbit/s connector
E1/T1(0~7)
2.048 MHz clock source output port, used to SMB male
TESTOUT2M1 2M0
TESTOUT2M1 2M0
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page47
Board- GEIU
There are DIP switches on GEIU, the default setting is to support
75Ω DIP Bit Description 75 Ω 120
switc Ω
h
S1 1 0 -7 of the Used to select the impedance on E1/ ON OFF
T1 links 7
2 8 -15 of the Used to select the impedance on E1/ ON OFF
T1 links 15
3 16 -23 of the Used to select the impedance on E1/ ON OFF
T1 links 23
4 24 -31 of the Used to select the impedance on E1/ ON OFF
T1 links 31
5- Unused ON OFF
8
S3 1- 0 -7 of the Used to set the protection grounding ON OFF
8 of the transmitting end of E1/ T1 links 7
S4 1- 8 -15 of the Used to set the protection grounding ON OFF
8 of the transmitting end of E1/ T1 links 15
S5 1- 16 -23 of the Used to set the protection ON OFF
8 grounding of the transmitting end of E1/ T1 links
23
S6 1- 24 -31 of the Used to set the protection ON OFF
8 grounding of the transmitting end of E1/ T1 links
31
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page48
Contents
1. System Description
2. Hardware Structure
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page49
Contents
3. System Logical Structure
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page50
System Logical Structure
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page51
TDM Switching Subsystem
The Time Division Multiplexing (TDM) switching subsystem
provides circuit switched domain (CS) switching for the system
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page52
TDM Access Bearer Unit
The TDM access bearer unit provides TDM bearers for the services on
the A, Abis and Ater interface. Each board has the same hardware
structure that contains backplane and sub board. By loading software,
the functions of A, Abis, Ater, and Pb interface can be enabled
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page53
TDM Switching Unit
Intra-Subrack TDM Switching
Board Board
Board
………
Connection between a board and the active GTNU through
a backplane TDM path
Connection between a board and the standby GTNU
through a backplane TDM path
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page54
TDM Switching Unit
Inter-Subrack TDM switching
Inter-subrack TDM switching is carried out through mesh
interconnections
Subrack 1 Subrack 4
Subrack 2 Subrack 3
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page55
GTNU Crossover Ethernet Cable
1 2 3
Pin14 Pin1
A B
W1 W3
Pin1 X1 X3 Pin14
A W2 W4 B
X2 X4
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page56
Inter-Subrack Interconnections
The right figure GMPS 0# GEPS 3#
GTNU GTNU GTNU GTNU
shows the
interconnections
of GTNU crossover
cables when four
service subracks GEPS 1# GEPS 2#
GTNU GTNU GTNU GTNU
are configured
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page57
GE Switching Subsystem
The Gigabit Ethernet (GE) switching subsystem performs GE switching
of signaling and O&M interface, packet message switching
The GSCU performs operation and maintenance of its subrack and
provides GE switching for the other boards in the same subrack
Board Board
Board
………
Intra-Subrack Connection
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page58
GE Switching Unit
Inter-subrack GE switching: star interconnection through
crossover networks
GEPS GTCS
GEPS GTCS
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page59
GE Switching Interconnection
GMPS/GSCU
GE 0
GE TRUNK1
GE 1 GSCU0 GSCU1
GE 0 1#GEPS
GE 2
GE TRUNK2
GE 3
GE 1 Cross LAN cables
GE 0
GE 4
GE TRUNK3 GE 1 2#GEPS GSCU0 GSCU1
GE 5
GE 0
GE 6 3#GEPS
GE TRUNK4
GE 1
GE 7
GE 8 GE 0
GE TRUNK4 GTCS Centre
GE 1
GE 9
GBAM/
GE TRUNK5 GE 10
GOMU LMT
GE TRUNK6 GE 11
M2000
CPU FE FE
LanSwitch
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page60
Service Processing Subsystem
The hardware entity of the service
processing subsystem is the
GDPUX board and GDPUP board
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page61
CS Service Processing Subsystem
The GDPUX processes CS services. In different
configuration modes of the BSC subracks, the GDPUX
performs different functions:
In BM/TC separated configuration mode, the GDPUX configured in
the GMPS/GEPS performs IP packet-TRAU conversion and
forwarding; the GDPUX configured in the GTCS performs voice
coding/decoding and rate matching
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page62
CS Service Processing Subsystem
The following takes the transmission of CS traffic signals
from the BSC to the MGW as an example. When IP
transmission is used on both the Abis interface and the A
interface, the CS DSP module processes traffic signals as
follows:
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page63
PS Service Processing Subsystem
The GDPUP processes PS services
When the HDLC transmission or IP transmission is
used on the Abis interface, the external PCU cannot
be used. In other words, the BSC must be configured
with the GDPUP to process PS services
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page64
PS Service Processing Subsystem
The following takes the transmission of PS signals from
the BSC to the SGSN as an example. When IP
transmission is used on the Abis interface and on the Gb
interface, the service processing procedure of the PS DSP
module is as follows:
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page65
Service Control Subsystem
The components of the BSC service control subsystem are
as follows:
GXPUM and GXPUT configured in the GMPS/GEPS
GBAM/GOMU
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page66
Interface Processing Subsystem
Physically the BSC interface processing subsystem consists of the
interface boards and the GXPUM.
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page67
Interface Processing Subsystem
Traffic Processing
GEIUB/GOIUB supports 256 TRXs
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page68
Clock Subsystem
The BSC clock subsystem consists of the GGCU and the
clock processing units in each subrack.
Each clock source either has one backup source or does not
have any backup
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page69
BSC Clock Synchronization (TC)
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page70
BSC Clock Synchronization
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page71
Clock Synchronization Interconnection
GMPS GEPS
GSCU GSCU
GGCU GGCU Y-shaped
cable
……
……
CLKIN CLKIN
GEPS
GSCU GSCU
CLKIN CLKIN
1
2 1
8
W2 1
8 X2
1 W1
X1 8
W3 1
X3
Copyright © 2008 Huawei Technologies Co., Ltd. All rights reserved. Page72
Thank you
www.huawei.com