Up/Down Counter

DIN size W72×H72, W144×H72mm 8Digit Up/Down counter


(A)
▣Features Counter

lCounting speed : 1cps, 30cps, 2kcps, 5kcps


lDisplay digit : 8digit(0~99999999) (B)
lEase to select 20 kinds of input operation modes and Timer

18 kinds of output operation modes by internal DIP switch.


lAvailable to set a decimal point
(C)
lWide range of input power supply: Temp.
controlle
100-240VAC 50/60Hz, 12-24VDC(Option)
lMicro computer built-in
(D)
Please read "Caution for your safety" in operation Power
! manual before using. controlle

▣Specifications (E)
Panel
Single preset F8A L8A meter
Model
Indication type F8B L8B
Digit 8(99999999) 8(99999999) (F)
Digit size W6.3×H10mm Tacho/
W4×H8mm
Speed/
Power supply 100-240VAC 50/60Hz, 12-24VDC(Option) Pulse
meter
Allowable voltage range 90 ~ 110% of rated voltage
U Preset : Approx. 5.4VA(240VAC 60Hz), U Preset : Approx. 6.1VA(240VAC 60Hz),
(G)
Approx. 3W(24VDC) Approx. 3.1W(24VDC) Display
Power consumption
U Indication type :Approx. 4.7VA(240VAC 60Hz), U Indication type : Approx. 5.4VA(240VAC 60Hz), unit
Approx. 2.6W(24VDC) Approx. 2.6W(24VDC)
Max.counting speed Selectable 1cps/30cps/2kcps/5kcps by internal DIP switch
(H)
Min. signal
RESET input Approx. 20ms Sensor
width controlle

CP1, CP2 [Voltage input] Input impedance : 5.4kΩ, "H" level voltage : 5-30VDC,
Input "L" level voltage : 0-2VDC
Input type (I)
[No-Voltage input] Impedance at short-circuit : Max. 1kΩ, Residual voltage at Proximit
RESET input short-circuit : Max. 2VDC, Impedance at open-circuit : Max. 100kΩ sensor

Con- Type Single preset : SPDT(1c)


Control tact Capacity 250VAC 3A resistive load (J)
output Solid- Type Single presetType : 1 NPN open collector Photo
electric
state Capacity 30VDC Max. 100mA Max. sensor

Memory retention 10 years(when using non-volatile memory semiconductor)


External sensor power 12VDC±10% 50mA Max. (K)
Ambient temperature -10 ~ +55℃(at non-freezing status) Pressur
sensor
Storage temperature -25 ~ +65℃(at non-freezing status)
Ambient humidity 35 ~ 85%RH
Insulation resistance 100MΩ(at 500VDC) (L)
Rotary
Dielectric strength 2000VAC 50/60Hz for 1 minute encoder
Noise AC power ±2kV the square wave noise(pulse width:1㎲) by the noise simulator
strength DC power ±500V the square wave noise(pulse width:1㎲) by the noise simulator (M)
5-Phase
Mechanical 0.75mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 1 hour stepping
Vibration mot or &
Malfunction 0.5mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 10 minutes Dr iver &
Controlle
Mechanical 300m/s²(Approx. 30G) in X, Y, Z directions 3 times
Shock
Malfunction 100m/s²(Approx. 10G) in X, Y, Z directions 3 times
Relay Mechanical Min. 10,000,000 times
life cycle Electrical Min. 100,000 times(250VAC 3A at resistive load)
AC power F8A : Approx. 287g, F8B : Approx. 253g L8A : Approx. 500g, L8B : Approx. 446g
Weight
DC power F8A : Approx. 283g, F8B : Approx. 253g L8A : Approx. 498g, L8B : Approx.444g

A-58
F/L Series

▣Dimensions
lF Series
126
lPanel cut-out
84
M in.91
72 13 102 11

68.5 +0.5
-0

Min.91
1 2 3 4 5 6 7 8

68.5 +0
-0
.5
RE SE T

TI ME

F8 A
Unit:mm

lL Series
lPanel cut-out
163 122

144 102 Min.170


10 10

OU T 67.5 +0.5
-0

- - -
PRESET

- - - - -
Min.76 +0.5
1 2 3 4 5 6 7 8
TI M E
138 -0
+ + + ++ + + + + R E SE T

L8 A
Unit:mm

▣Connections
lF8A lF8B
SOLID STATE OUT
12VDC 12VDC
CP1 CP2 50mA 0V RESET CP1 CP2 50mA 0V RESET

8 9 10 11 12 13 14 30VDC Max. 8 9 10 11 12 13 14
100mA M ax.

15 17 15 17

16 18 16 18
NO NC

COM

1 2 3 4 5 6 7 1 2 3 4 5 6 7
CONTACT OUT : ! !
250VAC 3A ~ ~
RESISTIVE LOAD - + - +
SOURCE SOURCE

lL8A lL8B

CONTACT OUT :
12VDC 250VAC 3A 12VDC
CP1 CP2 50mA 0V RESET RESISTIVE LOAD CP1 CP2 50mA 0V RESET
13 14 15 16 17 18 19 20 21 22 23 24 13 14 15 16 17 18 19 20 21 22 23 24
C OM

NC NO

1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12
S OLID STATE OUT ~ ! ~ !

30VDC Max. - + - +
100mA Max. SOURCE SOURCE

A-59
Up/Down Counter
▣Input logic selection
lF Series lL Series (A)
Counter
Input logic is changeable by input logic selection Input logic is changeable by input logic selection
switch located at the one-side of case. switch located at the terminal block.
U No voltage input(NPN) U Voltage input(PNP)
NPN NP N PNP
U No voltageinput(NPN) (B)
P NP
Timer
F S

U Voltage input(PNP)
F S (C)
Temp.
controlle

※Please be sure to turn OFF the power before changing input logic.

(D)

▣Input connections Power


controlle

◎Input logic : No-voltage input(NPN)


lSolid-state input(Standard input sensor : NPN output type sensor) lContact input (E)
Sensor Count/Timer S ensor Count/Timer Count/Timer Panel
meter
Brown Brown
+12V +12V +12V
RL
10kΩ 5.4kΩ 5.4kΩ 5.4kΩ
Black ※ Black ※ ※ (F)
Inner Inner Inner Tacho/
circuit circuit circuit Speed/
Blue Blue
0V 0V 0V Pulse
meter
(NP N output ) (NPN open Counting speed :
collector output) 1 or 30cps setting
※ CP1, CP2(INHIBIT), RESET input
(G)
Display
◎Input logic : voltage input(PNP) unit

lSolid-state input(Standard input sensor : PNP output type sensor) lContact input

Sensor Count/Timer S ensor Count/Timer Count/Timer


(H)
Brown Brown
+12V +12V +12V Sensor
controlle
Black ※ Inner Black ※ Inner ※ Inner
circuit circuit circuit
RL
10kΩ 5.4kΩ 5.4kΩ 5.4kΩ
Blue Blue
(I)
0V 0V 0V
Proximit
(PNP out put) (PNP open Counting speed : sensor
collector output) 1 or 30cps setting
※CP1, CP2(INHIBIT), RESE T input

(J)
▣Input & output connections Photo
electri c
sensor
◎In case of operating the load by power supply ◎In case of operating the load by external power supply
of the sensor (-) Ratesvoltage
(+) circuit
(K)
※ Load1 Pressur
Load1 sensor
Black Brown Blue
PR18-8DP 8 9 10 11 12 13 14
8 9 10 11 12 13 14 CP1 CP2 +12V 0V
CP1 CP2 +12V 0V
(L)
Rotary
encoder

(M)
5-Phase
stepping
1 2 3 4 5 6 7 motor &
1 2 3 4 5 6 7 - +
Driver &
(Power supply Controlle
- +
(Power supply ~
for t he load) Load2
for the load) Load2 ~ SOURCE
SOURCE
lThe capacity of the load must not be exceed Max. 30VDC,
Max. 100mA of the switching capacity of the transister.
lPlease select proper capacity of load, because total lPlease do not supply the reverse polarity voltage.
value of load capacity and current consumption ※In case of using the inductive load(Relay, etc.), please
should not be exceed current capacity(Max. 50mA). connector the surge absorber(Diode)at both terminals
of the load, in case of using the inductive load.

A-60
F/L Series
▣Selection by DIP switches
lW72×H72 DIP switch position lW144×H72 DIP switch position lSelecting memory retention
SW2 Function
3
ON Non memory
OFF
3
ON Memory
OFF

lSelecting max. counting speed



Output operation mode SW2 Max. counting speed
Input operation mode 1 2
ON 1cps
Memory retention selection OFF
Max. counting speed 1 2
ON 30cps
OFF
1 2
6 5 4 3 2 1 3 2 1
※Indication type has no 4, 5, 6 ON 2kcps
ON OFF
OFF mode of SW1.
1 2
ON 5kcps
SW1 SW2 OFF

▣Counting function(Indication type-F8B, L8B)


lUp mode lDown mode
RESET RESET
+Max.display value +Max.display value

0
0
-Max.display value

l Up / Down-A, B, C input mode lUp / Down-D, E, F mode

RESET RESET
+Max.display value +Max.display value

0 0

-Max.display value -Max.display value

▣Decimal point setting


Dispaly the decimal point.

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
R ESET RE SET RE SET RE SET

0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3
+ + + + TIME
+ + + + TIM E
+ + + + TIM E
+ + + + TIM E

FX4S FX4S FX4S FX4S

RUN mode Return to RUN mode


※It returns to decimal point ※When "dp" is flickering, ※If pressing one of digital ※It returns to RUN mode
setting status if pressing one touch the Reset switchbuttons( + , - ) in if pressing RESET button
RESET button for over button. decimal point setting mode, for over 3sec. in decimal
3sec. in RUN mode. decimal point will be moved point setting status.
to Up(+) direction.
lChanging the decimal point
※It returns to RUN mode if no RES ET button or
+ + + + digital switch is applied for 60sec. in decimal
point settingstetus.
- - - - ※The decimal point setting is existed in indication
(Factory def ault)
type.

A-61
Up/Down Counter
▣Input operation mode(Counter)
(A)
Input mode(SW1) No-voltage input type(NPN) Voltage input type(PNP) Counter

H H
cp1 cp1
Up/Down-A L A A L A A
2 3
ON H
Command cp2 L cp2 H (B)
L 3 3 Timer
input 3 3
OFF Counting 2 2 2 Counting 2 2 2
1 1 1 1
value 0 value 0

H H
cp1 cp1 L
Up/Down-B L (C)
2 3 H Temp.
Individual ON cp2 H cp2 L controlle
L 3 3
3 3
input Counting 2 2 2 Counting 2 2 2
OFF 1 1 1 1 1 1
value 0 value 0

H H (D)
Up/Down-C cp1 cp1 Power
L L B B B B
2 3 B B B B
controlle
Up Phase ON
cp2
H cp2 H
difference L L
mode 3 3 3 3
OFF 2 2 2 Counting 2 2 2
input Counting 1 1 1 1
value 0 value 0 (E)
Panel
H H meter
cp1 L cp1
A A L A A
H H
cp2 L cp2
L No counting
(F)
No counting
5 5 Tacho/
Counting 4 Counting 4
2 3 3 3 Speed/
value 2 value 2
ON 1 1 Pulse
Up 0 0 meter
Up input OFF No counting
cp1 H No counting cp1
H
L L A A (G)
A A
H H Display
cp2 L cp2 L unit
5 5
4 4
Counting 3 Counting 3
1 2 1 2
value 0 value 0
(H)
H
cp1 H cp1
L
Sensor
L A A A A controlle
Up/Down-D 2 3
ON H H
Command cp2 L cp2
L
n n-1 n n-1
OFF n-1 Counting n -1
input Counting n-2 n-2 n-2 n-2 n-2 n-2
n-3 n-3 value n-3 n-3 (I)
value
0 0 Proximit
sensor
H H
cp1 L cp1 L
Up/Down-E 2 3 H
ON cp2 L cp2 H
Individual L (J)
n n Photo
input OFF Counting n-1 n-2 n-2 n-1 n-1 n-2 Counting n-1 n-2 n-2 n-1 n-1 n-2
n-3 n-3 n-3 n-3 electric
value value
0 sensor
0

cp1 H cp1
H
Up/Down-F L
B B B B
L B B B B
2 3 (K)
Phase ON H cp2
H Pressur
Down cp2
L L
difference sensor
OFF
n Counting n n-1 n-1
mode input Counting n-1
n-2 n-3 n-2
n-1
n-2 n-2
n-3 n-2 n-2
value n-3 value n-3
0 0
H (L)
cp1 cp1 H Rotary
L A A L A A
encoder
H
cp2 L cp2 H
n No counting L No counting
n-1 n n-1
Counting n-2 Counting n-2 (M)
n-3 n-3
value n-4 n-5 value n-4 n-5 5-Phase
Down 2 3 stepping
ON 0 0 mot or &
Down input Dr iver &
No counting
OFF cp1 H No counting
cp1
H Controlle
L L
A A A A
H H
cp2 cp2 L
L
n n-1 n n-1
Counting n-2 Counting n-2
n-3 n-3 n-4
n-4 n-5 value n-5
value
0 0

※ A : Over Min. signal width, B : Over 1/2 of Min. signal width.


Counting miss by one(±1) is occured if the signal width of A or B is less than min. signal width.

A-62
F/L Series
▣Output operation mode
One-shot output(0.05 ~ 5sec) Self-holding output

4 4
Output mode ON ON
Up mode Down mode Operation after count up
(SW1) OFF OFF

F
RESET RESET The display value continues until
Setting Setting reset signal is applied and the
4 5 6 output will be held.
ON 0 0 U Self-holding output is held
OFF Output Output until reset signal is applied.

N
RESET RESET
The display value and self-
4 5 6 Setting Setting
ON holding output are held until
0 0 reset signal is applied.
OFF
Output Output

C
RESET RESET
The display value returns to reset
4 5 6 Setting Setting start status when display value is
ON reached to preset value.
0 0
OFF
Output Output
R
RESET RESET
Setting The display value is held until
4 5 6 Setting
ON output is OFF then returns to
0 0 reset start status.
OFF Output Output

K
RESET RESET
4 5 6 Setting Setting The display value continues
ON until reset signal is applied.
0 0
OFF
Output Output

P
RESET RESET The display value is held during
4 5 6 Setting Setting one-shot output time, counting
ON process is returned to reset start
0 0
OFF status when output is ON.
Output Output
Q
RESET RESET
4 5 6 Setting Setting The display value continues
ON during one-shot output time.
0 0
OFF
Output Output

S Up Down

RESET RESET
U Up, UP/Down-A, B, C input
Setting Setting mode
0 0 -Output is ON when
(Display value) ≥ (Preset value)
4 5 6 Output Output
ON U Down, UP/Down-D, E, F input
OFF mode
RESET RESET -Output is ON when
Setting Setting (Display value) ≤ (Zero)
0 0
Output Output

A-63
Up/Down Counter
▣Proper usage ◎Error display
Error signal Error description Returning method (A)
◎Reset function Counter

lReset Change the se value


Zero set state
to non zero state
In case of changing the input mode after supplying
the power, please take a external reset or manual ※When Error is displayed, the output continues OFF state.
(B)
※There is no Error function in the indication type. Timer
reset. If reset is not executed, the counter will
be working as previous mode.
lReset signal width (C)
It is reset perfectly when the reset signal is applied Temp.
_ _ _ _ controlle
during max. 20ms regardless of the contact input RESET
0 0 0 0
& solid-state input. + + + +
TIM E

* FX4S (D)
Power
controlle
Reset input ◎Power
** The inner circuit voltage starts to rise up for the
(E)
first 100ms after power on, the input may not work Panel
*In case of a contact reset, it is reset perfectly if meter
at this time. And also the inner circuit voltage drops
the ON time of reset signal is applied during max.
down for the last 500ms after power off, the input
20ms even though a chattering is occurred. (F)
may not work at this time. Tacho/
**It can be input the signal of CP1 & CP2 after max. Speed/
ON Pulse
50ms from closing time of reset signal. Power meter
OFF
100ms 500ms
◎Min.signal width of CP1, CP2 input The unstable time
against the input signal. (G)
*T Display
1 1 unit

(H)
** ** Sensor
controlle

*Please make duty ratio(ON/OFF) 1:1.


** Min. signal width 1cps : Max. 500ms (I)
30cps : Max. 16.7ms Proximit
2kcps : Max. 0.25ms sensor

5kcps : Max. 0.1ms

◎Max. counting speed (J)


Photo
This is respond speed per 1 sec. when the duty electric
sensor
ratio (ON/OFF) of input signal is 1:1. If duty ratio
is not 1:1, the respond speed will be getting slow
(K)
against input signal and also the width between ON Pressur
sensor
and OFF should be over min. signal width and also
one of ON width and OFF width is under min. signal
width, this product may not response. (L)
Rotary
encoder
Ta Tb Width of Ta(ON) and Tb(OFF)
must be larger than Min. signal
width. (M)
5-Phase
stepping
Max.counting speed is 1/2 value mot or &
3× Ta of catalog spec. when duty rate Dr iver &
Controlle
is 1:3.

It can not respond because Max.


signal width(1a) is little.