RRU5507

Hardware Description

Issue 01
Date 2017-09-30

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2017. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://www.huawei.com
Email: support@huawei.com

Issue 01 (2017-09-30) Huawei Proprietary and Confidential i


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description About This Document

About This Document

Purpose
This document provides reference for planning and deploying a DC blade RRU5507 (referred
to as RRU in this document). RRU is short for remote radio unit. It presents the exterior and
describes the ports, functions, cable types, connector specifications, and cable connections of
the RRU.

Product Versions
The following table lists the product versions related to the RRU.
Product Name Solution Version Product Version

RRU5507 l SRAN10.1 and later V100R010C10 and later


versions versions
l GBSS17.1 and later For details about the software
versions versions of RF modules, see
l RAN17.1 and later Software and Hardware
versions Compatibility Description.
l eRAN10.1 and later
versions

Intended Audience
This document is intended for:
l Base station installation engineers
l System engineers
l Site maintenance engineers

Organization
1 Changes in RRU5507 Hardware Description

Issue 01 (2017-09-30) Huawei Proprietary and Confidential ii


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description About This Document

This section describes the changes in RRU5507 Hardware Description.

2 RRU Introduction

This chapter describes the exterior and function of the RRU as well as the ports and indicators
on the RRU.

3 RRU Cables

This chapter describes RRU cables.

4 RF Cable Connections for the RRU5507

RF cable connections for the RRU vary depending on the configurations of the RRU and
antenna.

5 RRU Auxiliary Devices

This chapter describes RRU auxiliary devices.

Conventions
Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol Description

Indicates an imminently hazardous situation which, if not


avoided, will result in death or serious injury.

Indicates a potentially hazardous situation which, if not


avoided, could result in death or serious injury.

Indicates a potentially hazardous situation which, if not


avoided, may result in minor or moderate injury.

Indicates a potentially hazardous situation which, if not


avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.
NOTICE is used to address practices not related to personal
injury.

Calls attention to important information, best practices and


tips.
NOTE is used to address information not related to
personal injury, equipment damage, and environment
deterioration.

General Conventions

The general conventions that may be found in this document are defined as follows.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential iii


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description About This Document

Convention Description

Times New Roman Normal paragraphs are in Times New Roman.

Boldface Names of files, directories, folders, and users are in


boldface. For example, log in as user root.

Italic Book titles are in italics.


Courier New Examples of information displayed on the screen are in
Courier New.

Command Conventions
The command conventions that may be found in this document are defined as follows.

Convention Description

Boldface The keywords of a command line are in boldface.

Italic Command arguments are in italics.

[] Items (keywords or arguments) in brackets [ ] are optional.

{ x | y | ... } Optional items are grouped in braces and separated by


vertical bars. One item is selected.

[ x | y | ... ] Optional items are grouped in brackets and separated by


vertical bars. One item is selected or no item is selected.

{ x | y | ... }* Optional items are grouped in braces and separated by


vertical bars. A minimum of one item or a maximum of all
items can be selected.

[ x | y | ... ]* Optional items are grouped in brackets and separated by


vertical bars. Several items or no item can be selected.

GUI Conventions
The GUI conventions that may be found in this document are defined as follows.

Convention Description

Boldface Buttons, menus, parameters, tabs, window, and dialog titles


are in boldface. For example, click OK.

> Multi-level menus are in boldface and separated by the ">"


signs. For example, choose File > Create > Folder.

Keyboard Operations
The keyboard operations that may be found in this document are defined as follows.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential iv


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description About This Document

Format Description

Key Press the key. For example, press Enter and press Tab.

Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl
+Alt+A means the three keys should be pressed
concurrently.

Key 1, Key 2 Press the keys in turn. For example, pressing Alt, A means
the two keys should be pressed in turn.

Mouse Operations
The mouse operations that may be found in this document are defined as follows.

Action Description

Click Select and release the primary mouse button without


moving the pointer.

Double-click Press the primary mouse button twice continuously and


quickly without moving the pointer.

Drag Press and hold the primary mouse button and move the
pointer to a certain position.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential v


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description Contents

Contents

About This Document.....................................................................................................................ii


1 Changes in RRU5507 Hardware Description........................................................................... 1
2 RRU Introduction.......................................................................................................................... 2
2.1 RRU Exterior.................................................................................................................................................................. 2
2.2 RRU Functions............................................................................................................................................................... 4
2.3 RRU Technical Specifications........................................................................................................................................5
2.4 RRU Ports.......................................................................................................................................................................6
2.5 RRU Indicators............................................................................................................................................................... 7
2.6 Optical Modules............................................................................................................................................................. 9

3 RRU Cables...................................................................................................................................15
3.1 RRU Cable List............................................................................................................................................................ 16
3.2 RRU PGND Cable........................................................................................................................................................17
3.3 RRU Power Cable........................................................................................................................................................ 18
3.4 CPRI Fiber Optic Cable................................................................................................................................................19
3.5 RRU RF Jumper........................................................................................................................................................... 25
3.6 RRU AISG Multi-Wire Cable...................................................................................................................................... 26
3.7 RRU AISG Extension Cable........................................................................................................................................ 27

4 RF Cable Connections for the RRU5507................................................................................. 29


5 RRU Auxiliary Devices.............................................................................................................. 31

Issue 01 (2017-09-30) Huawei Proprietary and Confidential vi


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 1 Changes in RRU5507 Hardware Description

1 Changes in RRU5507 Hardware


Description

This section describes the changes in RRU5507 Hardware Description.

01 (2017-09-30)
This is the first official release.
Compared with Draft A (2017-06-30), this issue does not include any new information.
Compared with Draft A (2017-06-30), this issue includes the following changes.
Topic Change Description

About This Document Updated the required product versions and


added support of the RRU by the DBS5900.

Compared with Draft A (2017-06-30), no information is deleted from this issue.

Draft A (2017-06-30)
This is a draft.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 1


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

2 RRU Introduction

About This Chapter

This chapter describes the exterior and function of the RRU as well as the ports and indicators
on the RRU.

2.1 RRU Exterior


This section describes the exterior and dimensions of an RRU.
2.2 RRU Functions
This section describes main functions of an RRU.
2.3 RRU Technical Specifications
This section describes technical specifications of an RRU, including supported modes,
frequency bands, RF specifications, engineering specifications, and antenna capabilities.
2.4 RRU Ports
This section describes ports on the RRU panels. An RRU has a bottom panel, cabling cavity
panel, and indicator panel.
2.5 RRU Indicators
This section describes six indicators on an RRU. They indicate the running status of the RRU.
2.6 Optical Modules
An optical module transmits optical signals between an optical port and a fiber optic cable.

2.1 RRU Exterior


This section describes the exterior and dimensions of an RRU.
Figure 2-1 shows the exterior of an RRU.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 2


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

Figure 2-1 RRU exterior

Figure 2-2 shows RRU dimensions.

Figure 2-2 RRU dimensions

You can obtain the RRU name, RRU frequency band and power supply information from the
nameplate on the cover plate. Figure 2-3 shows the positions of the nameplate on the RRU.
NOTE

The actual nameplate may differ from what is shown in the figure.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 3


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

Figure 2-3 Positions of the nameplate

(1) Nameplate (2) Module name (3) Frequency band (4) Power supply type

2.2 RRU Functions


This section describes main functions of an RRU.
The Remote Radio Unit (RRU) consists of the high-speed interface unit, signal processing
unit, power amplifier, duplexer, extension ports, and power module.
Figure 2-4 shows the functional structure of the RRU.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 4


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

Figure 2-4 Functional structure of an RRU

NOTE

For details about the extension ports, see 2.4 RRU Ports.

The RRU performs the following functions:


l Receives downlink baseband data from the BBU and sends uplink baseband data to the
BBU.
l Receives RF signals from the antenna system, down-converts the signals to intermediate
frequency (IF) signals, amplifies the IF signals, performs analog-to-digital conversion,
and up-converts RF signals to the transmit (TX) band.
l Multiplexes receive (RX) and TX signals on the RF channel so that these signals can
share the same antenna channel, and filters the RX and TX signals.
l Provides a built-in Bias Tee (BT). Besides receiving and transmitting RF signals, RRU
RF ports A and B transmit OOK signals to antennas through the built-in BT. The RF
ports A, B, C, and D also supply DC power to the tower mounted amplifier (TMA).
l When an RRU is equipped with an AC/DC power module, the RRU and the power
module together are called an AC RRU. For details about the AC/DC power module, see
OPM15M(Ver.B) User Guide or OPM50M(Ver.B) User Guide.

2.3 RRU Technical Specifications


This section describes technical specifications of an RRU, including supported modes,
frequency bands, RF specifications, engineering specifications, and antenna capabilities.
For details about technical specifications of an RRU, see section Technical Specifications of
RRUs in the Base Station Technical Description.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 5


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

2.4 RRU Ports


This section describes ports on the RRU panels. An RRU has a bottom panel, cabling cavity
panel, and indicator panel.
Figure 2-5 shows the ports on the RRU panels.

Figure 2-5 Ports on the RRU panels

Table 2-1 describes ports and indicators on the RRU panels.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 6


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

Table 2-1 Ports and indicators on the RRU panels


Item Silkscreen Remarks

(1) Ports in the RTN(+) Power supply socket, For details about RRU
cabling cavity power cable appearance and specifications,
NEG(-) see 3.3 RRU Power Cable.

CPRI0 Optical/electrical port 0, connected to the


BBU or an upper-level RRU

CPRI1 Optical/electrical port 1, connected to a


lower-level RRU or the BBU

(2) Bottom ports A T01/R01 TX/RX port A (4.3-10 female connector),


supporting RET signal transmission

B T01/R01 TX/RX port B (4.3-10 female connector),


supporting RET signal transmission

C R01 RX port C (4.3-10 female connector)

D R01 RX port D (4.3-10 female connector)

RET Communication port for the RET antenna,


supporting RET signal transmission

(3) Indicator RUN For details, see 2.5 RRU Indicators.

ALM

ACT

VSWR

CPRI0

CPRI1

NOTE

l The port for transmitting RET signals is determined by the software.


l Connect the CPRI0 port to the BBU by default in the single-mode scenario.

2.5 RRU Indicators


This section describes six indicators on an RRU. They indicate the running status of the RRU.
For detailed positions of RRU indicators, see 2.4 RRU Ports.
Table 2-2 describes RRU indicators.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 7


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

Table 2-2 RRU Indicators


Indicator Color Status Meaning

RUN Green Steady on The power input is available, but the board
is faulty.

Steady off No power input is available, or the board is


faulty.

Blinking (on for The board is running properly.


1s and off for 1s)

Blinking (on for The board software is being loaded, or the


0.125s and off for board is not working.
0.125s)

ALM Red Steady on Alarms are generated, and the module must
be replaced.

Blinking (on for Alarms are generated. The alarms may be


1s and off for 1s) caused by faults on the related board or
ports. Therefore, you need to locate the
fault before deciding whether to replace the
module.

Steady off No alarms are generated.

ACT Green Steady on The board is working properly when TX


channels are enabled or software is being
loaded to a board that is not started.

Blinking (on for The board is running with TX channels


1s and off for 1s) disabled.

VSWR Red Steady off No voltage standing wave ratio (VSWR)


alarm is generated.

Blinking (on for VSWR alarms are generated on the B T/R


1s and off for 1s) port.

Steady on VSWR alarms are generated on the A T/R


port.

Blinking (on for VSWR alarms are generated on the A T/R


0.125s and off for and B T/R ports.
0.125s)

CPRI0 Red and Steady green The CPRI link is running properly.
green
Steady red An optical module fails to receive or
transmit signals possibly because the
optical module is faulty or the optical fiber
is broken.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 8


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

Indicator Color Status Meaning

Blinking red (on The CPRI link is out of lock because of


for 1s and off for faults on the mutual lock of dual-mode
1s) clock sources or mismatched data rates on
CPRI ports.

Steady off The optical module cannot be detected or is


powered off.

CPRI1 Red and Steady green The CPRI link is running properly.
green
Steady red An optical module fails to receive or
transmit signals possibly because the
optical module is faulty or the optical fiber
is broken.

Blinking red (on The CPRI link is out of lock because of


for 1s and off for faults on the mutual lock of dual-mode
1s) clock sources or mismatched data rates on
CPRI ports.

Steady off The optical module cannot be detected or is


powered off.

NOTE

VSWR indicators on RRUs providing one or more than two TX channels have two types of status:
l Steady off: No VSWR alarm is generated.
l Steady on: VSWR alarms are generated on one or more ports.

2.6 Optical Modules


An optical module transmits optical signals between an optical port and a fiber optic cable.

NOTE

l The exteriors of an optical module and the label on an optical module in this section are for
reference only. The actual exteriors may be different.
l Boards or RF modules supporting only the 1.25 Gbit/s CPRI port rate, for example, a GTMU or
RRU3908 V1, cannot use 10 Gbit/s optical modules.
l A fiber optic cable must use the same type of optical modules on its two ends. If different types of
optical modules are used by a fiber optic cable, performance risks may arise, for example, alarms, bit
errors, and interrupted links.
l Only Huawei-certified optical modules meeting the following requirements can be used for Huawei
wireless devices:
l Requirements of devices on which optical modules are to be installed
l Laser safety in the IEC 60825-1 standard
l General safety in the IEC 60950-1 standard
l For SFP or QSFP optical modules certified and provided by Huawei, see Spare Parts Catalog.

The following figures show the exteriors of optical modules.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 9


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

Figure 2-6 Exteriors of optical modules (SFP)

a: Two-fiber bidirectional optical module b: Single-fiber bidirectional optical module

Figure 2-7 Exteriors of optical modules (QSFP)

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 10


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

a: 100G BIDI optical module b: Single-fiber bidirectional optical module

Figure 2-8 Exteriors of optical modules (QSFP)

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 11


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

a: 100G SR4 optical module b: Two-fiber bidirectional optical c: Single-fiber bidirectional optical
module module

a: 100G BIDI optical module b: Single-fiber bidirectional optical module

NOTE

QSFP optical modules are applicable only to BBUs, massive MIMO devices, and radio multiplex units
(RMUs), but not to RRUs. In addition, only QSFP optical modules with a data rate of 40 Gbit/s are
applicable to the RMUs.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 12


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

Label on an Optical Module


There is a label on each optical module, which provides information such as the rate,
wavelength, and transmission mode, as shown in the following figure.

Figure 2-9 Label on an optical module (SFP)

(1) Rate (2) Wavelength (3) Transmission mode

Figure 2-10 Label on an optical module (QSFP)

(1) Rate (2) Wavelength (3) Transmission mode

(1) Rate (2) Wavelength (3) Transmission mode (4) Connected module

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 13


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 2 RRU Introduction

There are different types of optical modules which are configured depending on the actual
application scenarios, see CPRI Fiber Optic Cable in 3900 Series Base Station Cables5900
Series Base Station Cables.

Optical Module Type


Optical modules can be divided into single- and multimode optical modules, which can be
distinguished as follows:
l The puller of a single-mode optical module is blue and the puller of a multimode optical
module is black or gray.
l The transmission mode is displayed as "SM" on the label of a single-mode optical
module and "MM" on the label of a multimode optical module.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 14


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

3 RRU Cables

About This Chapter

This chapter describes RRU cables.

3.1 RRU Cable List


This section describes RRU cable connections.
3.2 RRU PGND Cable
An RRU PGND cable connects an RRU and a ground bar, ensuring the proper grounding of
the RRU. The maximum length of an RRU PGND cable is 8 m (26.25 ft).
3.3 RRU Power Cable
The RRU power cable is a -48 V DC shielded cable. It feeds -48 V DC power to an RRU. The
maximum length of power supply that an RRU power cable supports is 100 m (328.08 ft).
3.4 CPRI Fiber Optic Cable
CPRI fiber optic cables are classified into multimode fiber optic cables and single-mode fiber
optic cables. They transfer CPRI signals.
3.5 RRU RF Jumper
The 1/2" RRU RF jumper transmits and receives RF signals between an RRU and an antenna.
A fixed-length RF jumper used by an RRU is 2 m (6.56 ft), 3 m (9.84 ft), 4 m (13.12 ft), 6 m
(19.68 ft), or 10 m (32.81 ft). A variable-length RF jumper used by an RRU has a maximum
length of 10 m (32.81 ft).
3.6 RRU AISG Multi-Wire Cable
An RRU AISG multi-wire cable connects an RRU and an RCU to transmit control signals
from a base station to an RET antenna. When the RRU is connected to the RET antenna, an
AISG multi-wire cable transmits RS485 signals. The length of the AISG multi-wire cable is 5
m (16.40 ft).
3.7 RRU AISG Extension Cable
When the distance between an RRU and an RCU is longer than 5 m (16.4 ft), an AISG multi-
wire cable is not long enough to connect the RRU and the RCU. In this case, an AISG
extension cable is used to extend the AISG multi-wire cable for transmitting RS485 signals.
The length of the AISG extension cable is 15 m (49.21 ft).

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 15


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

3.1 RRU Cable List


This section describes RRU cable connections.
Table 3-1 lists RRU cables.

Table 3-1 RRU cables


Cable One End The Other End

Connector Installation Connector Installation


Position Position

3.2 RRU OT terminal Ground OT terminal Ground terminal


PGND Cable (M6, 16 mm2 or terminal on (M8, 16 mm2 or on the ground
0.025 in.2) the RRU 0.025 in.2) bar

3.3 RRU Power Female fast NEG(-) and Depending on External power
Cable connector RTN(+) ports the power equipment
(pressfit type) on the RRU supply
equipment

3.4 CPRI Fiber DLC connector CPRI0 port on DLC connector CPRI port on a
Optic Cable the RRU board in the
BBU or CPRI1
port on the
upper-level
RRU

CPRI1 port on CPRI0 port on


the RRU the lower-level
RRU or CPRI
port on a board
in the BBU

3.5 RRU RF 4.3-10 male RF ports on 4.3-10 male Antenna system


Jumper connector the RRU connector
NOTICE
Select cables
based on the
type of the
connector at the
other end of the
cable on live
networks.

3.6 RRU AISG DB9 waterproof RET port on Standard AISG Standard AISG
Multi-Wire male connector the RRU female male connector
Cable connector on the RCU or
on the AISG
extension cable

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 16


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

Cable One End The Other End

Connector Installation Connector Installation


Position Position

3.7 RRU AISG Standard AISG Standard Standard AISG Standard AISG
Extension male connector AISG female female male connector
Cable connector on connector on the RCU
the AISG
multi-wire
cable

3.2 RRU PGND Cable


An RRU PGND cable connects an RRU and a ground bar, ensuring the proper grounding of
the RRU. The maximum length of an RRU PGND cable is 8 m (26.25 ft).

Exterior
A PGND cable is green or green and yellow with a cross-sectional area of 16 mm2 (0.025 in.
2). An OT terminal is installed at each end of the cable. Figure 3-1 shows a PGND cable.

Figure 3-1 PGND cable

(1) OT terminal (M6, 16 mm2 or 0.025 in.2) (2) OT terminal (M8, 16 mm2 or 0.025 in.2)

NOTE

l If the customer prepares the PGND cable, a copper-core cable with a cross-sectional area of 16 mm2
(0.025 in.2) or larger is recommended.
l One OT terminal must be added to each end of the PGND cable onsite.
l You can determine the color of the cable and whether to use corresponding two-hole OT terminals
based on local regulations.

Figure 3-2 shows a two-hole OT terminal.

Figure 3-2 Two-hole OT terminal

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 17


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

3.3 RRU Power Cable


The RRU power cable is a -48 V DC shielded cable. It feeds -48 V DC power to an RRU. The
maximum length of power supply that an RRU power cable supports is 100 m (328.08 ft).

NOTE

If a power device provided by the customer is used, the recommended specification of the circuit breaker
on this power device is 25 A to 30 A.

Exterior
A female fast connector (pressfit type) needs to be added to one end of the RRU power cable
and a corresponding terminal needs to be added to the other end based on the requirements of
the connector on the external power device, as shown in Figure 3-3.

Figure 3-3 RRU power cable

(1) -48 V DC power cable (2) Shield layer (3) Female fast connector (pressfit
type)

The outer diameter of RRU power cables ranges from 9.9 mm to 14.4 mm, and Table 3-2 lists
the specifications of an RRU power cable.

Table 3-2 Specifications of an RRU power cable

RRU Type National Remote Cross- OCB


Standard Distance Sectional Quantity
Area of the
Cable

RRU5507 European 0 m to 70 m 6 mm2 0


standard
71 m to 100 m 10 mm2 2

American 0 m to 70 m 5.3 mm2 0


standard
71 m to 100 m 8.2 mm2 0

Table 3-3 lists the wire colors of an RRU power cable.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 18


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

Table 3-3 Wire Colors of an RRU power cable


Cable Wire Wire Color in Most Wire Color in Other
Regions Regions

North European UK China


American Standard
Standard

RRU RTN(+) Black Brown Blue Red


power
cable NEG(-) Blue Blue Gray Blue

3.4 CPRI Fiber Optic Cable


CPRI fiber optic cables are classified into multimode fiber optic cables and single-mode fiber
optic cables. They transfer CPRI signals.
A multimode fiber optic cable connects a BBU to an RRU or connect two RRUs. The
maximum length of a multimode fiber optic cable connecting a BBU and an RRU is 150 m
(492.12 ft). The default length of a multimode fiber optic cable connecting two RRUs is 10 m
(32.81 ft). If the distance between two RRUs exceeds 10 m (32.81 ft), contact Huawei
engineers.
The single-mode fiber optic cable can be divided into two types: single-mode fiber optic cable
directly connecting a BBU to an RRU or connects two RRUs (shortened to directly connected
single-mode fiber optic cable) and single-mode fiber optic cable connecting an ODF to a BBU
or RRU (shortened to single-mode pigtail). The length of each single-mode fiber optic cable
between the BBU and RRU or between RRUs cannot exceed the maximum allowed remote
distance between the BBU and RRUs. The maximum length of the single-mode pigtail
between an ODF and a BBU is 20 m (65.62 ft). The maximum length of the single-mode
pigtail between an ODF and an RRU is 70 m (229.66 ft).

NOTE

l The ODF is an outdoor transfer box for fiber optic cables, which interconnects the single-mode
pigtail and trunk single-mode fiber optic cable.
l The ODF and trunk single-mode fiber optic cable are provided by the customer and must comply
with the ITU G.652 standard.
l A multimode fiber optic cable is used together with a multimode optical module, and a single-mode
pigtail is used together with a single-mode optical module.

Selection Principle
The following table describes the principles for selecting CPRI fiber optic cables.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 19


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

Table 3-4 Principles for selecting CPRI fiber optic cables


Remot CPRI Selection Principle Connects...to... Remarks
e Data
Distan Rate of
cea the
Optical
Module
(Gbit/s)

≤ 100 2.5 or 4.9 Multimode fiber optic Connects a BBU to When multiple
m cable an RRU or connect RRUs are
(328.08 two RRUs. cascaded,
ft) 9.8 Directly connected multimode fiber
single-mode fiber optic optic cables and
cable single-mode fiber
optic cables can
be used together.

100 m All Recommended: single- Connects a BBU to The single-mode


(328.08 mode fiber optic cable an RRU. pigtail at the
ft) < (single-mode pigtail and RRU or BBU
Remote trunk single-mode fiber side is connected
distanc optic cable) to the trunk
e ≤ 150 single-mode fiber
m optic cable by
(492.12 using an ODF.
ft)
2.5 or 4.9 Multimode fiber optic Connects a BBU to When multiple
cable an RRU or connect RRUs are
two RRUs. cascaded,
9.8 Directly connected multimode fiber
single-mode fiber optic optic cables and
cable single-mode fiber
optic cables can
be used together.

> 150 - Single-mode fiber optic Connects a BBU to The single-mode


m cable (single-mode an RRU. pigtail at the
(492.12 pigtail and trunk single- RRU or BBU
ft) mode fiber optic cable) side is connected
to the trunk
single-mode fiber
optic cable by
using an ODF.

≤ 70 m 40 or 100 OM3 multimode fiber Connects a BBU to Short-distance


(229.66 optic cable an AAU. connection
ft) between the BBU
and RRU

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 20


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

Remot CPRI Selection Principle Connects...to... Remarks


e Data
Distan Rate of
cea the
Optical
Module
(Gbit/s)

70 m 40 or 100 OM4 multimode fiber


(229.66 optic cable
ft) <
Remote
distanc
e ≤ 100
m
(328.08
ft)

100 m 40 or 100 Directly connected Connects a BBU to -


to 1000 single-mode fiber optic an RRU.
m cable
(328.08
ft to 40 or 100 Single-mode fiber optic Connects a BBU to The single-mode
3280.8 cable (single-mode an RRU. pigtail at the
ft) pigtail and trunk single- RRU or BBU
mode fiber optic cable) side is connected
to the trunk
single-mode fiber
optic cable by
using an ODF.

a: The remote distance between the BBU and RRUs refers to the total length of the cables
between the BBU and the RRU that is farthest way from the BBU.

Exterior
Multimode fiber optic cable or directly connected single-mode fiber optic cable: The
cable has a DLC connector at each end, as shown in the following figure.

Figure 3-4 Multimode fiber optic cable or directly connected single-mode fiber optic cable

(1) DLC connector (2) Breakout cable (3) Label on the breakout cable

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 21


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

NOTE

l When a fiber optic cable connects a BBU3900/BBU3910/BBU5900 to an RRU, the breakout cable
on the BBU side is 0.34 m (1.12 ft) and the breakout cable on the RRU side is 0.03 m (0.098 ft).
l When a fiber optic cable connects a BBU3910A/BBU3910C to an RRU, the breakout cables on the
BBU side and the RRU side are both 0.03 m (0.098 ft).

The following figure shows the connection of the multimode fiber optic cable or directly
connected single-mode fiber optic cable between a BBU and an RRU as an example.

Figure 3-5 Connection of the multimode fiber optic cable or directly connected single-mode
fiber optic cable between a BBU and an RRU

(1) Multimode fiber optic cable or directly connected single-mode fiber optic cable between a BBU and an
RRU

Trunk fiber optic cable for an OFD06: The trunk fiber optic cable for an OFD06 connects a
BBU to an OFD06 and has 12 LC connectors at each end, as shown in the following figure.

Figure 3-6 OFD06 trunk fiber optic cable

(1) LC connector (2) Breakout cable (3) Label on the breakout cable

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 22


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

Single-mode pigtail: The single-mode pigtail has a DLC connector at one end and an FC,
LC, or SC connector at the other end, as shown in the following figure.

Figure 3-7 Exterior of a single-mode pigtail

(1) DLC (2) Breakout (3) Label on the (4) FC (5) LC (6) SC
connector cable breakout cable connector connector connector

NOTE

l When a single-mode pigtail connects a BBU to an ODF, the breakout cables on the BBU side and
ODF side are 0.34 m (1.12 ft) and 0.8 m (2.62 ft), respectively.
l When a single-mode pigtail connects an RRU to an ODF, the breakout cables on the RRU side and
ODF side are 0.03 m (0.098 ft) and 0.8 m (2.62 ft), respectively.

The following figure shows the connection of the single-mode pigtail.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 23


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

Figure 3-8 Connection of the single-mode pigtail

(1) Single-mode pigtail between a BBU and an ODF (2) Single-mode pigtail between an RRU and an ODF

The OM3 and OM4 multimode fiber optic cables have the same exterior, in which each end
has an MPO connector. The MPO connector with a strap connects to the BBU and the MPO
connector without a strap connects to the RRU, as shown in the following figure.

Figure 3-9 OM3/OM4 multimode fiber optic cable

(1) MPO connector (2) Strap (3) MPO connector

Pin Assignment
The following table describes the labels on the breakout cables of a CPRI fiber optic cable
and recommended cable connections.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 24


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

Table 3-5 Labels on the breakout cables of a CPRI fiber optic cable and recommended cable
connections
Label on the Installation Position
Breakout Cable
Connection Connection Connection
Between a BBU Between RRUs Between a BBU or
and an RRU or RRU and an ODF
Between an
OFD06 and an
RRU

1A CPRI RX port on the CPRI RX port on RX port on the BBU or


RRU RRU 1 CPRI RX port on the
RRU

1B CPRI TX port on the CPRI TX port on TX port on the BBU or


RRU RRU 1 CPRI TX port on the
RRU

2A OFD06 or TX port CPRI TX port on ODF


on the BBU RRU 0

2B OFD06 or RX port CPRI RX port on ODF


on the BBU RRU 0

3.5 RRU RF Jumper


The 1/2" RRU RF jumper transmits and receives RF signals between an RRU and an antenna.
A fixed-length RF jumper used by an RRU is 2 m (6.56 ft), 3 m (9.84 ft), 4 m (13.12 ft), 6 m
(19.68 ft), or 10 m (32.81 ft). A variable-length RF jumper used by an RRU has a maximum
length of 10 m (32.81 ft).

NOTE

l When the distance between an RRU and an antenna is less than 10 m (32.81 ft), one end of the RF jumper
is connected to an RF port at the bottom of the RRU, and the other end is connected to the antenna.
l When the distance between an RRU and an antenna is greater than 10 m (32.81 ft), it is recommended
that one end of the RF jumper be connected to an RF port at the bottom of the RRU, the other end be
connected to one end of the feeder, and the other end of the feeder be connected to the antenna.
l If the customer prepares the RF jumper, the length of the RF jumper should be as short as possible and
not exceed 2 m (6.56 ft.).

Exterior
For an RF jumper, one end is connected to a 4.3-10 male connector, and the other end is
connected to a connector based on onsite requirements, which is a 4.3-10 male connector or
DIN male connector.
Figure 3-10 shows an RF jumper with two ends connected to 4.3-10 male connectors.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 25


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

Figure 3-10 RF jumper

(1) 4.3-10 male connector

3.6 RRU AISG Multi-Wire Cable


An RRU AISG multi-wire cable connects an RRU and an RCU to transmit control signals
from a base station to an RET antenna. When the RRU is connected to the RET antenna, an
AISG multi-wire cable transmits RS485 signals. The length of the AISG multi-wire cable is 5
m (16.40 ft).

NOTE

An RCU is a driving motor used for the phase shifter in the RET antenna. It receives control commands from
a base station and runs the commands to drive the stepper motor. Using a gear, the stepper motor drives the
adjustable phase shifter in the antenna and changes the downtilt angle.

Exterior
An AISG multi-wire cable has a waterproof DB9 male connector at one end and a standard
AISG female connector at the other end, as shown in Figure 3-11.

Figure 3-11 AISG multi-wire cable

(1) Waterproofed DB9 male connector (2) Standard AISG female connector

Pin Assignment
Table 3-6 describes the pin assignment for the wires of an AISG multi-wire cable.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 26


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

Table 3-6 Pin assignment for the wires of an AISG multi-wire cable

X1 End (Pin of X2 End (Pin of the Color Type Description


the Standard AISG
Waterproofed Female Connector)
DB9 Male
Connector)

White and
blue Twisted
X1.1 X2.1 +12 V
pair
Blue

X1.3 X2.3 White and RS485 B


orange Twisted
pair
X1.5 X2.5 Orange RS485 A

X1.4 X2.4 White and - GND


green

X1.9 and X1.4 are - - - GND


interconnected.

- X2.1 and X2.6 are - - +12 V


interconnected.

- X2.4 and X2.7 are - - GND


interconnected.

3.7 RRU AISG Extension Cable


When the distance between an RRU and an RCU is longer than 5 m (16.4 ft), an AISG multi-
wire cable is not long enough to connect the RRU and the RCU. In this case, an AISG
extension cable is used to extend the AISG multi-wire cable for transmitting RS485 signals.
The length of the AISG extension cable is 15 m (49.21 ft).

Exterior
An AISG multi-wire cable has a standard AISG male connector at one end and a standard
AISG female connector at the other end, as shown in Figure 3-12.

Figure 3-12 AISG extension cable

(1) Standard AISG male connector (2) Standard AISG female connector

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 27


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 3 RRU Cables

Pin Assignment
Table 3-7 describes the pin assignment for the wires of an AISG extension cable.

Table 3-7 Pin assignment for the wires of an AISG extension cable
X1 End (Pin X2 End (Pin Color Type Description
of the of the
Standard Standard
AISG Male AISG
Connector) Female
Connector)

X1.1 X2.1 White and blue Twisted pair +12 V

Blue

X1.7 X2.7 White and Twisted pair DC Return


orange

Orange

X1.3 X2.3 White and green Twisted pair RS485 B

X1.5 X2.5 Green RS485 A

X1.6 X2.6 White and brown Twisted pair +24 V

Brown

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 28


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 4 RF Cable Connections for the RRU5507

4 RF Cable Connections for the RRU5507

RF cable connections for the RRU vary depending on the configurations of the RRU and
antenna.

Description of RF Cable Connections


This section describes the RF cable connections for the RRU serving a single sector. The
following tables list the RF cable connections for the RRU.

Table 4-1 RF cable connections for the RRU


RRU Model Specifications of Scenario Illustration of Cable
a Single RRU Connections

RRU5507 For details, see the 2T2R See illustration 1 in Figure


typical power 4-1.
configuration of
the corresponding 1T2R+1T2R See illustration 2 in Figure
RRU in "Technical 4-1.
Specifications of 2T4R See illustration 3 in Figure
RRUs" of Base 4-1.
Station Technical
Description.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 29


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 4 RF Cable Connections for the RRU5507

Illustration of Cable Connections

Figure 4-1 RF cable connections for the RRU

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 30


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 5 RRU Auxiliary Devices

5 RRU Auxiliary Devices

This chapter describes RRU auxiliary devices.

Indoor Floor installation Support


An Indoor Floor installation Support (IFS06) is used for installing indoor RRUs.

For details about the exterior, specifications, and installation of an IFS06, see the Base Station
Hardware Description and DBS3900 (ICR) Installation Guide.

Outdoor Pole Support


OFP06, short for Outdoor Flexible Pole For 6, is an outdoor pole support and provides a
solution for extended installation of Huawei products on towers or building tops.

For details about the exterior and installation of an OFP06, see the OFP06 Installation Guide.

OCB
An Outdoor Cable Conversion Box (OCB) interconnects cables of different core diameters.
Power cables shipped with RRUs cannot support long-distance power supply. Therefore,
when power supply is far from the equipment, cables with large core diameters are used, and
an OCB connects these cables and RRU power cables.

For details about the structure, functions, installation, and maintenance of an OCB, see the
OCB User Guide or OCB–01M User Guide.

Power Module
Power module is used to convert external AC input power into -48 V DC for the DC RRU,
including the following type:

l OPM15M(Ver.B): supported by V100R010C10 and later.


l OPM50M(Ver.B): supported by V100R010C10 and later.

For details about the structure, functions, installation, and maintenance of a Power Module,
see the OPM15M(Ver.B) User Guide or OPM50M(Ver.B) User Guide.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 31


Copyright © Huawei Technologies Co., Ltd.
RRU5507
Hardware Description 5 RRU Auxiliary Devices

Distribution Equipment
The ODM03D is small distribution equipment, which supports RRU capacity expansion,
power cable reuse, and fiber optic cable reuse.
For details about the structure, functions, installation, and maintenance of an ODM03D, see
the ODM03D User Guide.

RMU
A RMU3900A (Outdoor Distribution Module) is a radio multiplex unit, which converges and
deconverges CPRI data and saves CPRI fiber optic cables between a BBU and RRUs.
RMU3900A: supported by V100R012C00 and later.
For details about the structure, functions, installation, and maintenance of a RMU3900A, see
the RMU3900A User Guide.

MEB
The Monitoring Extension Box (MEB) can convert external RS-485 communication signals
and dry node alarm signals into power return circuit signals, implementing power supply
monitoring.
MEB: supported by V100R010C10 and later.
For details about the structure, functions, installation, and maintenance of a MEB, see the
MEB06D User Guide.

Issue 01 (2017-09-30) Huawei Proprietary and Confidential 32


Copyright © Huawei Technologies Co., Ltd.
RRU
Technical Specifications 3 Technical Specifications of RRUs

Table 3-87 Specifications of CPRI ports on an RRU5508

Type Numbe CPRI CPRI Cascading Maximum Distance


r of Data Topology Level from a BBU (km)
CPRI Rate
Ports (Gbit/s)

RRU55 2 1.25, 2.5, Star, chain, CPRI MUX: LTE FDD/GL/UL/GUL:


08 4.9, or or dual-star l GL/UL: 4 The maximum distance
9.8 from the BBU varies with
l GUL: 4
the types of LTE BBPs
configured.
l When the LBBPc, or
LBBPd1 is configured:
20
l When the LBBPd2,
UBBPd3, UBBPd4,
UBBPd5, UBBPd6, or
UBBPe is configured:
40
l When the LBBPd3 is
configured
– 40 if the cell
number is less than
or equal to 3
– 20 if the cell
number is greater
than or equal to 4

Antenna Capability
The following table lists the antenna capability of an RRU5508.

Table 3-88 Antenna capability of an RRU5508

Type TMA Support Supported RET Antenna

RRU5508 Supported AISG2.0

NOTE

For RF modules supporting RET antennas, the feeding voltage is 12 V and feeding current is 2.3 A.

3.11 RRU5507 Technical Specifications


An RRU5507 is a multimode remote radio unit. Adopting the software-defined radio (SDR)
technology, an RRU5507 supports different RATs through software configurations.

Issue 03 (2018-11-26) Copyright © Huawei Technologies Co., Ltd. 98


RRU
Technical Specifications 3 Technical Specifications of RRUs

Supported RATs and Frequency Bands


The following table lists the RATs and frequency bands supported by an RRU5507.

Table 3-89 RATs and frequency bands supported by an RRU5507


Type Frequency Receive Transmit RAT IBW
Band Frequency Frequency (MHz)
(MHz) Band Band
(MHz) (MHz)

RRU550 1800+2100 1800: 1710 to 1800: 1805 to 1800: LTE FDD, 1800: 40
7 1785 1880 GL, LM, GLM 2100: 40
2100: 1920 to 2100: 2110 to 2100: UMTS, LTE
1980 2170 FDD, UL
1800+2100: LTE
FDD, GL, UL,
GUL, LM, GLM,
ULM

NOTE

An RRU5507 can operate in the 1800 MHz frequency band, 2100 MHz frequency band, or both frequency
bands.

RF Specifications
Table 3-90 lists the RF specifications of an RRU5507.

NOTE

l ATBR in the Transmit and Receive Channels column indicates that this RF module has A transmit
channels and B receive channels.
l CxD W in the Output Power column indicates that this RF module is configured with C transmit
channels and the maximum output power of each transmit channel is D W.
l EF MSR indicates that E and F data is carried on the same transmit channel of an RF module.
l EF non-MSR indicates that E and F data is carried on two different transmit channels of an RF module.
l GSM receiver sensitivity is measured, as recommended in 3GPP TS 51.021, at the antenna connector on
condition that the channel rate reaches 13 kbit/s and the bit error rate (BER) is not higher than 2%.
l UMTS receiver sensitivity is measured, as recommended in 3GPP TS 25.104, at the antenna connector on
condition that the channel rate reaches 12.2 kbit/s and the BER is not higher than 0.001.
l LTE FDD receiver sensitivity is measured, as recommended in 3GPP TS 36.104, under a 5 MHz channel
bandwidth based on the FRC A1-3 in Annex A.1 (QPSK, R = 1/3, 25 RBs) standard.
l NB-IoT receiver sensitivity is measured, as recommended in 3GPP TS 36.104, under a 200 KHz channel
bandwidth and a 15 KHz subcarrier spacing based on the FRC A14-1 in Annex A.14 (π/2 BPSK, R = 1/3,
1 RB) standard.
l The typical power consumption for an RRU module is measured when the RRU load reaches 50% and the
ambient temperature is 25°C.

Issue 03 (2018-11-26) Copyright © Huawei Technologies Co., Ltd. 99


RRU
Technical Specifications 3 Technical Specifications of RRUs

Table 3-90 RF specifications of an RRU5507


Ty Tr Capacit Receiver Sensitivity (dBm) Output Power Power
pe an y Consumpt
s Receive Receive Receive ion for an
mi r r r RRU
t Sensitiv Sensitiv Sensitiv
an ity with ity with ity with
d One Two Four
Re Antenn Antenn Antenn
ce a as as
iv
e
C
ha
nn
el
s

RR 2T UMTS: GSM: – GSM: – GSM: – The RRU5507 1800 MHz


U5 4R l 8 114.0 116.8 119.5 supports the +2100
507 carrie UMTS: UMTS: (theoreti maximum MHz: 450
rs –126.1 –128.9 cal power W
witho value) configuration of
LTE LTE 2x100 W. For
ut FDD: – FDD: – UMTS:
MIM –131.6 typical power
106.9 109.7 configurations,
O LTE
NB-IoT: NB-IoT: see Typical
l 4 -127.3 -130.1 FDD: – Power
carrie 112.4 Configuration
rs NB-IoT: for RRUs
with -132.8 (Excluding NB-
MIM IoT) and NB-
O IoT Typical
LTE Power
FDD: 2 Configurations
carriers, (RRU).
the
bandwidt
h per
carrier is
5, 10, 15,
or 20
MHz.
NB-IoT:
1 carrier

Engineering Specifications
The following table lists the equipment specifications of an RRU5507.

Issue 03 (2018-11-26) Copyright © Huawei Technologies Co., Ltd. 100


RRU
Technical Specifications 3 Technical Specifications of RRUs

Table 3-91 Equipment specifications of an RRU5507


Type Input Power Dimensions (H x W x Weight (kg)
D)

RRU5507 –48 V DC; voltage 400 mm x 300 mm x 21 (without the


range: –36 V DC to – 150 mm (without the housing)
57 V DC housing)

NOTE
The RRU5507 supports AC power supply when connected to an external AC/DC power module or an
OPM15M. For details, see AC/DC Power Module User Guide and OPM15M User Guide.

The following table lists the environmental specifications of an RRU5507.

Table 3-92 Environmental specifications of an RRU5507


Type Operating Relative Absolute Atmospheric
Temperature Humidity Humidity Pressure

RRU55 l Without solar 5% RH to 100% 1 g/m3 to 30 g/m3 70 kPa to 106 kPa


07 radiation: – RH
40°C to +55°C
l With solar
radiation: –
40°C to +50°C

NOTE

According to the installation scenario, traffic load, and carrier configuration, the output power of some RRUs
may temporarily decrease when they work within the range of 10°C higher than the allowed highest
temperature.

The following table lists the compliance standards for an RRU5507.

Table 3-93 Compliance standards for an RRU5507


Item Standard

RF l 3GPP TS 45.005
l 3GPP TS 25.141
l 3GPP TS 36.141
l 3GPP TS 37.141

Operating environment ETSI EN 300019-1-4 V2.1.2 (2003-04) Class 4.1: "Non-


weatherprotected locations"

Issue 03 (2018-11-26) Copyright © Huawei Technologies Co., Ltd. 101


RRU
Technical Specifications 3 Technical Specifications of RRUs

Item Standard

Storage environment ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weather


protected, not temperature-controlled storage locations"
NOTE
l The validity period is one year.
l The product can function properly within the validity period if
the storage environment meets the preceding standards.

Shockproof protection NEBS GR63 zone4

Ingress Protection Rating IP65

Surge protection l IEC 62305-1 Protection against lightning - Part 1:


General principles
l IEC 62305-3 Protection against lightning - Part 3:
Physical damage to structures and life hazard
l IEC 62305-4 Protection against lightning - Part 4:
Electrical and electronic systems within structures
l ITU-T K.35 Bonding configurations and earthing at
remote electronic sites
l ITU-T K.56 Protection of radio base stations against
lightning discharges
l ITU-T K.97 Lightning protection of distributed base
stations
l ETSI EN 300 253 Environmental Engineering(EE):
Earthing and bonding configuration inside
telecommunications centers
l YD/T 2324-2011 Lightning protection requirements and
test methods for Radio Base Stations (RBSs)
l GB 50689-2011 Code for design of lightning protection
and earthing engineering for telecommunication bureaus
(stations)

Table 3-94 lists the surge protection specifications of ports on an RRU5507.

NOTE

l Unless otherwise specified, the surge protection specifications depend on the surge waveform of 8/20 μs.
l All the surge current items, unless otherwise specified as Maximum discharge current, refer to
Nominal discharge current.

Table 3-94 Surge protection specifications of ports on an RRU5507

Port Surge Protection Surge Protection Specifications


Mode

Power supply port Surge current 20 kA

Issue 03 (2018-11-26) Copyright © Huawei Technologies Co., Ltd. 102


RRU
Technical Specifications 3 Technical Specifications of RRUs

Specifications of CPRI Ports


The following table lists the specifications of CPRI ports on an RRU5507.

Issue 03 (2018-11-26) Copyright © Huawei Technologies Co., Ltd. 103


RRU
Technical Specifications 3 Technical Specifications of RRUs

Table 3-95 Specifications of CPRI ports on an RRU5507


Type Number of CPRI Data CPRI Cascading Maximum
CPRI Ports Rate Topology Level Distance
(Gbit/s) from a
BBU (km)

RRU5507 2 1.25, 2.5, Star, chain, CPRI MUX: GL/UL:


4.9, or 9.8 or dual-star l GL/UL: The
4 maximum
l GUL: 4 distance
from the
l LM: 4 BBU varies
l GLM/ with the
ULM: 4 types of LTE
BBPs
configured.
l When the
LBBPc,
or
LBBPd1
is
configure
d: 20
l When the
LBBPd2,
UBBPd3,
UBBPd4,
UBBPd5,
UBBPd6,
or
UBBPe
is
configure
d: 40
l When the
LBBPd3
is
configure
d
– 40 if
the
cell
numb
er is
less
than
or
equal
to 3

Issue 03 (2018-11-26) Copyright © Huawei Technologies Co., Ltd. 104


RRU
Technical Specifications 3 Technical Specifications of RRUs

Type Number of CPRI Data CPRI Cascading Maximum


CPRI Ports Rate Topology Level Distance
(Gbit/s) from a
BBU (km)

– 20 if
the
cell
numb
er is
greate
r than
or
equal
to 4
LM: 20
GLM/ULM:
20

Antenna Capability
The following table lists the antenna capability of an RRU5507.

Table 3-96 Antenna capability of an RRU5507


Type TMA Support Supported RET Antenna

RRU5507 Supported AISG2.0

NOTE

For RF modules supporting RET antennas, the feeding voltage is 12 V and feeding current is 2.3 A.

3.12 RRU5502w Technical Specifications


An RRU5502w is a multimode remote radio unit. Adopting the software-defined radio (SDR)
technology, an RRU5502w can work in different modes through software configurations.

Supported RATs and Frequency Bands


The following table lists the RATs and frequency bands supported by an RRU5502w.