TENDER NOTICE NO. : DGVCL/Civil/2016/RSO Navsari/52

TENDER DOCUMENT FOR

“Providing Compound wall, Shed, toilet facility , Borewell & RCC


Road @ RSO Navsari.”

TECHNICAL BID – PART - 2

INDEX

Sr.No. Description Page No.

TECHNICAL BID
1 Tender Notice 4-5
2 General Instructions to Tenderer 6-12
3 Special note for post-qualification. 13-14
4 Forms for Post qualification 15-28
5 Checklist for submission of bid 29-30
6 Scope of work 31-33
7 Special Conditions of the work 34-40
8 Labour laws 41-43
9 Tender& Contract for works 44-63
10 General Conditions of Contract 64-75
11 Formats 76-82
12 Technical Specifications for Civil Works / Electrical Works 83-305
13 List of Mandatory Test 306-315

14 List of Approved Makes – Civil-Plumbing-Electrical 316-356

15 List of Indian Standards Codes 357-370


16 Quality Assurance Plan 371-387
17 Drawing 388-391

Signature of Contractor 83
Sr.No. Description Page No.

PRICE BID 392

18 Schedule A 401-449
19 Schedule B 450-498

TECHNICAL SPECIFICATIONS FOR CIVIL WORKS / ELECTRICAL WORKS

GENERAL TECHNICAL SPECIFICATIONS FOR BUILDING WORKS GENERAL:

1. In the specifications "as directed" / "approved" shall be taken to mean "as directed" /
"approved by the Engineer-in-Charge".

2. Wherever a reference to any Indian Standard appears in the specifications, it shall be taken
to mean as a reference to the latest edition of the same in force on the date of agreement.

3. In "Mode of Measurement" in the specifications wherever a dispute arises in the absence of


specific mention of a particular point of aspect the provisions on these particular points, or
aspects in the relevant Indian Standards shall be referred to

4. All measurements and computations, unless otherwise specified, shall be carried out nearest
to the following limits:

(i) Length, width and depth (height) 0.01 meter


(ii) Areas 0.01 Sq.Mt.
(iii) Cubic Contents 0.01 Cu.Mt.

In recording dimensions of work the sequence of length, width and height (depth) or thickness
shall be followed.

5. The distance which constitutes lead shall be determined along the shortest practical route
and note necessarily the route actually taken The decision of the Engineer-in-charge in this
regard shall betaken as final.

6. Where no lead is specific, it shall mean "all leads"

7. Lift shall be measured from plinth level.

8. Up to "floor two level" means actual height of floor (Maxi 4 M) up to 3 Mt. above plinth level.

9. Definite particulars covered in the items of work, though not mentioned or elucidated in it
specifications shall be deemed to be included therein.

10. Reference to specifications of materials as made in the detailed specification of the items of
works is in the form of a designation containing them Number of the specification of the
material and prefix 'M‟ e.g. 'M-5',

Signature of Contractor 84
11. Approval to the samples of various materials given by the Engineer-in-charge shall not
absolve the contractor from the responsibility of replacing defective material brought on site or
materials used in the work found defective at a later date. The contractor shall have no claim to
any payment or compensation whatsoever on account of any such materials being rejected by
the Engineer-in-charge.

12. The contract rate of the item of work shall be for the work completed in all aspects.

13. No collection of materials shall be made before it is got approved from the Engineer-in-
charge.

14. Collection of approved materials shall be done at site of work in a systematic manner.
Materials shall be stored in such a manner as to prevent damage, deterioration or intrusion of
foreign matter and to ensure the preservation of their quality and fitness for the work

15. Materials, if and when rejected by the Engineer-in-charge, shall be immediately removed
from the site of work.

16. No materials shall be stored prior to, during and after execution of a structure in such a way
as to cause or lead to damage or overloading of the various components of the structure.

17. All works shall be carried out in a workmanlike manner as per the best techniques for the
particular item.

18. All tools, templates, machinery and equipment for correct execution of the work as well as
for checking lines, levels, alignment of the works during execution shall kept in sufficient
numbers and in good working condition on the site of the work.

19. The mode, procedure and manner of execution shall be such that it does not cause damage
or over-loading of the various components of the structure during execution or after completion
of the structure.

20. Special modes of construction not adopted in general Engineering practice if proposed to be
adopted by the Contractor, shall be considered only if the contractor provides satisfactory
evidence that such special mode 6 Of construction is safe, sound and helps in speedy
construction and Completion of work to the required strength and quality. Acceptance of the
same by the Engineer-in-Charge shall not, however absolve the contractor of the responsibility
of any adverse effects and consequences of adopting the same in the course of execution of
completion of the work.

21. All installations pertaining to water supply and fixtures there of as well as drainage lines and
sanitary fittings shall be deemed to be completed only after giving satisfactory tests by the
contractor.

22. The contractor shall be responsible for observing the rules and regulations imposed under
the "Minor Minerals Act", and such of the laws and rules prescribed by Government form to
time.

Signature of Contractor 85
23. All necessary safety measures and precautions {including those laid down in the various
relevant Indian Standards) shall be taken to ensure to ensure the safety of men. Materials and
machinery on the works as also of the work itself.

24. The testing charges of all materials shall be borne by the Contractor.

25. Approval to any of the executed items for the work does not in any relieve the contractor of
his responsibility for the correctness, soundness and strength of the structure as per the
drawings and specifications

SPECIFICATIONS OF MATERIALS
M-1. Water:

Water shall not be salty or brackish and shall be clean, reasonably clear and free from
objectionable quantities of silt and traces of oil and injurious alkalis, salts, organic matter and
other deleterious material which will either weaken the mortar or concrete or cause
efflorescence or attack the steel in R.C.C Container for transport, storage and handling of water
shall be clean. Water shall conform to the standards specified I.S 456-1978.

If required by Engineer-in-charge it shall be tested by comparison with distilled water.


Comparison shall be made by means of standard cement tests for soundness, time of setting
and mortar strength as specified in I.S.269-1976. Any indication of unsoundness, change in
time of setting by 30 minutes or more or decrease of more than 10 per cent in strength of
mortar prepared with water sample when compared with the results obtained with mortar
prepared with distilled water shall be sufficient cause for rejection of water under test.

Water for curing mortar, concrete or masonry should not be too acidic or too alkaline. It shall
be free of elements which significantly affect the hydration reaction or otherwise interfere with
the hardening of concrete during curing or those which produce objectionable stains or other
unsightly deposits on concrete or mortar surfaces.

Hard and bitter water shall not be used for curing.

Potable water will be generally found suitable for curing mortar or concrete.

M-2. Lime :
Lime shall be hydraulic lime as per I.S. 712-1973. Necessary test shall be carried out as per I.S.
6932(Parts I to X), 1973.

The following field tests for limes are to be carried out :

A very rough idea can be formed about the type of lime by its visual examination i.e. fat lime
bears pure white color, lime in form of porous lumps of dirty while color indicates quick lime,
and solid lumps are the unburnt lime stone.

Acid tests for determining the carbonate content in lime. Excessive amount of impurities and
rough determination of class of lime.

Signature of Contractor 86
Storage shall comply with I.S. 712-1973. The slaked lime, if stored, shall be kept in a weather
proof and damp-proof shed with impervious floor and sides to protect it against rain, moisture,
weather and extraneous materials mixing with it. All lime that has been damaged in any way
shall be rejected and all rejected and all rejected materials shall be removed from site of work.
Field testing shall be done according to I.S. 1624-1974 to show the acceptability of materials.

M-3. Cement:

Cement shall be ordinary Portland slag cement as per I.S. 269-1976 or Portland slag cement as
per I.S. 455-1976.

M-4. White Cement :

4.1 The white cement shall conform to I.S. 80412-E 1978.

M-5. Colored Cement :

5.1 Colored cement shall be with white or gray Portland cement as specified in the item of
the work.

5.2 The pigments used for colored cement shall be of approved quality and shall not exceed
10% of cement used in the Mix. The mixture of pigment shall be properly grounded to have a
uniform color and shade. The pigments shall have such properties to provide for durability
under exposure to sunlight and weather.

5.3 The pigment shall have the property such that it is neither affected by the cement nor
detrimental to it.

M-6 Sand :

Sand shall be natural sand, clean, well graded, hard strong durable and gritty particle free from
injurious amounts of dust clay, kankar nodules, soft or flaky particles shale, alkali, salts organic
matter, loam, mica or other deleterious substance and shall be got approved from the Engineer-
in-charge. The sand shall not contain more that 8 percent of silt as determined by field test. If
necessary the sand shall be washed to make it clean.

Coarse Sand : The fineness modulus of coarse sand shall not be less than 2.5 and shall not
exceed 3.0.

The sieve analysis or coarse shall be as under :

I.S. Sieve Percentage by I.S. Sieve Percentage by


Designation weight Designation weight
Passing sieve Passing sieve

4.75 mm. 100 600 Micron 30-100


2.36 mm. 90 to 100 300 Micron 5-70
1.18 mm. 70-100 150 Micron 0-50

Signature of Contractor 87
6.3 Fine Sand : The fineness modulus shall not exceed 1.0. The sieve analysis of fine sand
shall be as under :

I.S. Sieve Percentage by I.S. Sieve Percentage by


Designation weight Designation weight
Passing through Passing through

4.75 mm. 100 600 Micron 40-85


2.36 mm. 100 300 Micron 5-50
1.18 mm. 70-100 150 Micron 0-10

M-7 Stone Dust :

7.1 This shall be obtained from crushing hard black trap or equivalent. It shall not contain
more than 8% of silt as determined by field test with measuring cylinder. The method of
determining silt contents by field test is given as under :
7.2 A sample of stone dust to be tested shall be placed without drying in 200 mm.
measuring cylinder. The quantity of the sample shall be such that it fills the cylinder up to 100
mm. The clean water shall be added up to 150 mm. mark. The mixture shall be stirred
vigorously and the content allowed to settle for 3 hours.

7.3 The height of silt visible as settled layer above the stone dust shall be expressed as
percentage of the height of the stone dust below. The stone dust containing more that 8% silt
shall be washed so as to bring the silt content within the allowable limit.

7.4 The fineness modulus of stone dust shall not be less than 1.80.

M-8 Stone Grit :

Grit shall consist of crushed or broken stone and be hard strong, dense, durable, clean, of
proper gradation and free from skin or coating likely to prevent adhesion of mortar Grit shall
generally be cubical in shape and as far as possible flaky clongated pieces shall be avoided. It
shall generally comply with the provisions of I.S. 383-1970. Unless special stone of particular
quarries is mentioned, grit shall be obtained from the best black trap or equivalent hard stone
as approved by the Engineer-in-charge. The grit shall have no deleterious reaction with cement.

The grit shall conform to the following gradation as per sieve analysis :

I.S. Sieve Percentage I.S. Sieve Percentage


Designation Passing Designation Passing
through sieve through sieve

12.50 mm. 100 % 4.75 mm. 0-20%


10.00 mm. 85-100% 2.36 mm. 0-25%
The crushing strength of grit will be such as to allow the concrete in which it is used to built up
the specified strength of concrete.

Signature of Contractor 88
The necessary tests for grit shall carried out as per the requirements of I.S.2386 (Parts I to VII)
1963, as per instructions of the Engineer-in-charge. The necessity of test will be decided by the
Engineer-in-charge.

M-9 Cinder :

Cinder is well burnt furnace residue which has been fused or sintered into lumps of varying
sizes.
Cinder aggregates shall be well burnt furnace residue obtained from furnace using coal fuel
only. It shall be sound clean free from clay, dirt, ash or other deleterious matter.

The average grading for cinder aggregates shall be as mentioned below :

I.S. Sieve Percentage I.S. Sieve Percentage


Designation Passing Designation Passing

20 mm. 100 4.75 mm. 70


10 mm. 86 2.36 mm. 52

M-10 Lime Mortar :

Lime shall conform to specification M-2. Water shall conform to specification M-1.

Sand : Sand shall conform to specification M-6.

Proportion of Mix: 10.2.1. Mortar shall consist of such proportions of slaked lime and sand
as may be specified in the item. The slaked lime and sand be measured by volume.

Preparation of Mortar: 10.3.1. Lime mortar shall be prepared by wet process as per I.S.
1625-1971. Power driven mill shall be used for preparation of lime mortar. The slaked lime shall
be placed in the mill in an even layer and ground for the 180 revolutions with a sufficient water.
Water shall be added as required during grinding (care being taken not to add more water) that
will bring the mixed material to a consistency of stiff paste. Thoroughly wetted sand shall then
be added evenly and the mixture ground for another 180 revolutions.

Storage : 10.4.1 Mortar shall always be kept damp, protected from sun and rain till used up,
covering it by tarpaulin or open sheds.

Use : 10.5.1 All mortar shall be used as soon as possible after grinding. It should be used on
the day on which it is prepared. But in no case mortar made earlier than 36 hours shall be
permitted for use.

M-11. Cement Mortar :

Water shall conform to specification M-1. Cement : Cement shall conform to specification M-3.
Sand : Sand shall conform to M-6.

Proportion of Mix : 11.2.1 Cement and sand shall be mixed to specified proportion, sand
being measured by measuring boxes. The proportion of cement will be by volume on the basis

Signature of Contractor 89
of 50 Kg./Bag of cement being equal to 0.0342 Cu. m. The mortar may be hand mixed or
machine mixed as directed.
Preparation of Mortar: 11.3.1 In hand mixed mortar cement and sand in the specified
proportions shall be thoroughly mixed dry on a clean impervious platform by turning over at
least 3 times or more till a homogenous mixture of uniform color is obtained. Mixing platform
shall be so arranged that no deleterious extraneous material shall get mixed with mortar or
mortar shall flow out. While mixing, the water shall be gradually added and thoroughly mixed to
form a stiff plastic mass of uniform color so that each particle of sand shall be completely
covered with a film of wet cement. The water cement ratio shall be adopted as directed.

11.3.1 The mortar so prepared shall be used within 30 minutes of adding water. Only such
quantity of mortar shall be prepared as can be used within 30 minutes.

M-12 Stone Coarse Aggregate for Nominal Mix Concrete:

Coarse aggregate shall be machine crushed stone of black trap or equivalent and be hard,
strong, dense, durable, clean and free from skin and coating likely to prevent proper adhesion
of mortar.

The aggregate shall generally be cubical in shape. Unless special stones of particular quarries
are mentioned aggregates shall be machine crushed from the best black trap or equivalent hard
stone as approved. Aggregate shall have no deleterious reaction with cement. The size of the
coarse aggregate for plain cement concrete and ordinary reinforced cement concrete shall
generally be as per the table given below, However in case of reinforced cement concrete the
maximum limit may be restricted to 6 mm. less than the minimum lateral clear distance
between bars or 6 mm. less than the cover, whichever is smaller.

TABLE

I.S. Sieve Percentage passing for I.S. Sieve Percentage passing for
Designation single sized aggregates Designation single sized
of nominal size aggregates of Nominal
size
40 20 16 40 20 16
mm. mm. mm. mm. mm. mm.
80 mm. -- -- -- 12.5 mm. -- -- --
63 mm. 100 -- -- 10 mm. 0.5 0.02 0.30
40 mm. 85-100 100 -- 4.75 mm. -- 0.5 0.5
20 mm. 0-20 85-100 100 2.35 mm. -- --
mm.
16 mm. -- -- 85-100

Note : This percentage may be varied some what by Engineer-in-charge when considered
necessary for obtaining better density and strength of concrete.

The grading test shall be taken in the beginning and at the change of source of materials. The
necessary test indicated in I. S. 383-1970 and I.S. 456-1978 shall have to be carried out to be
carried out to ensure the acceptability. The aggregates shall be stored separately and handled
in such a manner as to prevent the intermixing of different aggregates. If the aggregates are
covered with dust, they shall be washed with water to make them clean.

Signature of Contractor 90
M-13 Black Trap or Equivalent Hard Stone Coarse :

Aggregate for Design mix Concrete: Coarse aggregate shall be of machine crushed stone of
black trap or equivalent hard stone and be hard strong dense, durable clean and free from skin
and coating likely to prevent proper adhesion of mortar.

The aggregates shall generally be cubical in shape. Unless special stones of particular quarries
are mentioned, aggregates shall be machine crushed from the best, black trap or equivalent
hard stones as approved. Aggregate shall have no deleterious reaction with cement.

The necessary tests indicated in I.S. 383-1970 and I.S. 456-1978 shall have to be carried out to
ensure the acceptability of the material.

If aggregate is covered with dust it shall be washed with water to make it clean.

M-14 Brick Bats Aggregate :

14.1 Brickbat aggregate shall be broken from well burnt or slightly over burnt and dense
brick. It shall be homogeneous in texture roughly cubical in shape, clean and free from dirt of
any other foreign material. The brickbats shall be of 40 mm. to 50 mm. size unless otherwise
specified in the item. The under burnt of over burnt brick bats shall not be allowed.

14.2 The brickbats shall be measured by volume by suitable boxes or as directed.


M-15 Bricks :

15.1 The bricks shall be hand or machine molded and made from suitable soils and klin-
burnt. They shall be free from crack and nodules of free lime. They shall have smooth
rectangular faces with sharp corners and shall be of uniform color.
The bricks shall be molded with a frog of 100 mm. x 40 mm. and 10 mm. to 20 mm. deep on
one of its flat sides. The bricks shall not break when thrown on the ground from a height of 600
mm

15.2 The size of modular bricks shall be 190 mm. x 90 mm. x 90 mm.

15.3 The size of the conventional bricks shall be as under :

(9” x 4 ⅜ “ x 2 ¾ “) 225 x 110 x 75 mm.

15.4 Only bricks of one standard size shall be used on one work. The following tolerances
shall be permitted in the conventional size adopted in a particular work.
Length : 1.8(3.0 mm.) Width : 1/6” (1.51 mm.) Height : 1/6” (1.50 mm.)

15.5 The crushing strength of the bricks shall not be less than 35 Kg./Sq. Cm. The average
water absorption shall not be more than 20 percent by weight. Necessary tests for crushing
strength and water absorption etc. shall be carried out as per I. S. 3495 (Part-I to IV) 1976.

M-16 Stone :

Signature of Contractor 91
The stone shall be of the specified variety such as Granite/Trap Stone/Quartzite or any other
type of good hard stones. The Stones shall be obtained only from the approved quarry and shall
be hard, sound, durable and free from defects like cavities, cracks, sand holes, flaws, injurious
veins, patches of loose or soft materials etc. and weathered portions and other structural
defects or imperfections tending to affect their soundness and strength. The stone with round
surface shall not be used. The percentage of water absorption shall not be more than 5% of dry
weight, when tested in accordance with I.S. 1134-1974. The minimum crushing strength of the
stone shall be 200 Kb/Sq. Cm. unless otherwise specified.

The samples of the stone to be used shall be got approved before the work is started.

The Khanki facing stone shall be dressed by chisel as specified in the item for khanki facing in
required shape and size. The face of stone shall be so dressed that the bushing on the exposed
face shall not project by more than 40 mm. from the general wall surface and on face to be
plastered it shall not projected it shall not project by more than 19 mm. nor shall it have
depressions more than 10 mm. from the average wall surface.

M-17 Laterite Stone :

17.1 Laterite stone shall be obtained from the approved quarry. It shall be compacted in
texture, sound, durable and free from soft patches. It shall have a minimum crushing strength
of 100 Kg./Sq. Cm. In its dry condition. It shall not absorb water more than 20% of its own
weight, when immersed for 24 hours in water. After quarrying the stone shall be allowed to
weather for some time before using in work.

17.2 The stone shall be dressed into regular rectangular blocks so that all faces are free
waviness and unevenness, edges true and square.
17.3 Those types of stone in which white clay occure, should not be used.

17.4 Special corner stones shall be provided where so directed.

M-18 Mild Steel Bars :

Mild steel bars reinforcement for R.C.C. work shall conform to I.S. 432 (Part-II) 1966 and shall
be of tested quality. It shall also comply with relevant part of I.S. 456-1978.

All the reinforcement shall be clean and free from dirt, paint, grease, mill scale or loose or thick
rust at the time of placing.
For the purpose of payment, the bar shall be measured correct up to 100 mm. length and
weight payable worked out at the rate specified below :

1. 6 mm. x 0.22 Kg./Rmt. 8. 20 mm. 2.47


Kg./Rmt.
2. 8 mm. x 0.39 Kg./Rmt. 9. 22 mm. 2.98
Kg./Rmt.
3. 10 mm. x 0.62 Kg./Rmt. 10. 25 mm. 3.85
Kg./Rmt.
4. 12 mm. x 0.89 Kg./Rmt. 11. 28 mm. 4.83
Kg./Rmt.
5. 14 mm. x 1.21 Kg./Rmt. 12. 32 mm. 6.31
Signature of Contractor 92
Kg./Rmt.
6. 16 mm. x 1.58 Kg./Rmt. 13. 36 mm. 7.99
Kg./Rmt.
7. 18 mm. x 3.00 Kg./Rmt. 14. 40 mm. 9.86
Kg./Rmt.

M-19A High Yield Strength Steel Deformed Bars :

High yield strength steel deformed bars be either cold twisted or hot rolled, shall conform to I.
S. 1739-1966 and I. S. 1139-1966 respectively.

Other provision and requirements shall conform to specification No. M-18 for mild steel bars.

M-19B TMT BARS:

19.1 TMT BARS shall confirm to I.S. 1786-1985 OF Fe-415 Grade or above form Approved
quality.

19.2 Other provision and requirements shall conform to specification No. M-18 for mild steel
bars.

M-20 High Tensile Steel Wire :

The high tensile wires for the use in pre-stressed concrete work shall conform to I. S. 2090-
1962.

The tensile strength of the high tensile steel bars shall be as specified in the item. In absence of
the given strength, the minimum strength shall be taken as per para 6.1 of I.S. 1785-1962.
Testing shall be done as per I.S. requirements.
The high tensile steel shall be free from loose mill scale, rust oil, grease, or any other harmful
matter. Cleaning of steel bars may be carried our by immersion in solvent solution, wire
brushing or passing through a pressure box containing carborundum.

The high tensile wire shall be obtained from manufactures in coil having diameter not less than
350 times the diameter of wire itself so that wire springs back straight on being uncoiled.

M-21 Mild Steel Binding Wire :

The mild steel wire shall be of 1.63 mm. or 1.22 mm. (16 or 18 gauge) diameter and shall
conform to I. S. 280-1972.

The use of black wire will be permitted for binding reinforcement bars. It shall be free from
rust, oil paint, grease, loose mill scale or any other undesirable coating which may prevent
adhesion of cement mortar.

M-22 Structural Steel :

All structural steel shall conform to I. S. 226-1965. The steel shall be free from the defects
mentioned in I. S. 226-1975 and shall have a smooth finish. The materials shall be free from

Signature of Contractor 93
loose mill scale, rust pits or other defects affecting the strength and durability. Rivet bars shall
conform to I. S. 1148-1973.

When the steel is supplied by the Contractor test certificates of the manufactures shall be
obtained according to I. S. 226-1975 and other relevant Indian Standards.

M-23 Galvanized Iron Sheets :

The galvanized iron sheets shall be plain or corrugated sheets of specified in item. The G. I.
Sheets shall conform to I. S. 277-1977. The sheets shall be undamaged in carriage and
handling either by rubbing off of zinc coating or otherwise they shall have clean and bright
surface and shall be free from dents, holes, rust or white powdery deposit.
The length and width of G. I. Sheet shall be as directed as per site condition.

M-23-A G. I. Valleys gutter ridges :

23.A.1. The G. I. Ridges and hips shall be of plain galvanized sheets class-3 of the thickness as
specified in item. These shall be 600 mm. in width and properly bent up to shape without
damage to the sheets in process of bending.

23.A.2. Valleys gutters and flashings shall also be galvanized sheets of thickness as specified in
item. Valleys shall be 900 mm. wide overall and finishing shall be 380 mm. wide overall. They
shall be bent to the required shape without damage to the sheet in the process of bending.

M-24 Asbestos Cement Sheets :

24.1 Asbestos cement sheets plain, corrugated or semi corrugated shall conform to I. S. 459-
1970.

24.2 Ridges & Hips :

24.2.1 Ridges and hips shall be of same thickness at that of A. C. sheets. The types of ridges
suitable for the type of sheets and locations.

24.2.2 Other accessories to be used in roof such as flashing pieces, caves filler pieces, valley
gutters, north light and ventilator curves, barge boards etc. shall be standard manufacture and
shall be suitable for the type of sheets and location.

M-25 Mangalore Pattern Roof Tiles :

The Mangalore pattern tiles shall conform to I. S. 654-1972 for Class „A‟ type as specified in
item. Samples of the tiles to be provided shall be got approved from the Engineer-in-charge.
Necessary tests shall be carried out as directed.

M-26 Shuttering :

26.1 The shuttering shall be either of wooden planking of 30 mm. minimum thickness with
or without steel lining or of steel plates stiffened by steel angles. The shuttering shall be
supported on battens and beams and props of vertical bellies properly cross braced together so

Signature of Contractor 94
as to make the centering rigid. In places of bullie props, brick pillar of adequate section built in
mud mortar may be used.

26.2 The form work shall be sufficiently strong and shall have camber, so that it assumes
correct shape after deposition of the concrete and shall be able to resist forces caused by
vibration of live load of men working over it and other incidental loads associated with it. The
shuttering shall have smooth and even surface and its joints shall not permit leakage of cement
grout.

26.3 If at any stage of work during or after placing concrete in the structure, the form work
sags or bulges out beyond the required shape of the structure, the concrete shall be removed
and work redone with fresh concrete and adequately rigid form work. The complete form work
shall be got inspected by and got approved from the Engineer-in-charge, before the
reinforcement bars are placed in position.

26.4 The props shall consist of bullies having 100 mm. minimum diameters measured at mix
length and 80 mm. at thin end and shall be placed as per design requirement. These shall rest
squarely on wooden sole plates 40 mm. thick and minimum bearing area if 0-10 sq. m. laid on
sufficiently hard base.

26.5 Double wedges shall further be provided between the sole plate and the wooden props
so as to facilitate tightening and easing of shuttering without jerking the concrete. The timber
used in shuttering shall not be so dry as to absorb water from concrete and swell or bulge nor
so green or wet as to shrink after erection. The timber shall be properly sawn and planed on
the sides and surface coming in contact with concrete. Wooden form work with metal sheet
lining or steel plates stiffened by steel angles shall be permitted.

26.6 As far as practicable, clamps shall be used to hold the forms together and use of nails
and spikes avoided.

26.7 The surface of timber shuttering that would come in contact with concrete shall be well
wetted and coated with soap solution before the concreting is done. Alternatively coat of raw
linseed oil or oil of approved manufacturer may be applied in place of soap solution. In case of
steel shuttering either soap solution or raw linseed oil shall be applied after thoroughly cleaning
the surface. Under no circumstances black or burnt oil shall be permitted.
26.8 The shuttering for beams and slabs shall have camber of 4 mm. per meter (1 in 250) or
as directed by the Engineer-in-charge so as to offset the subsequent deflection. For cantilevers,
the camber at free end shall be 1/50 of the projected length or as directed by the Engineer-in-
charge.

M-27 Expansion joints Premolded filter :

The item provides for expansion joints in R.C.C. frame structures for internal joints, as well as
exposed joints, with the use of premoulded bituminous joints filler.Premoulded bituminous
joints filler, i.e. performed strip of expansion joint filler shall not get deformed or broken by
twisting, bending or other handling when exposed to atmospheric condition. Pieces of joint filler
that have been damaged shall be rejected. Thickness of the pre-moulded joint filler shall be 25
mm. unless otherwise specified. Premoulded bituminous joint filler shall conform to I.S. 1838-
1961.

Signature of Contractor 95
M-28 Expansion joints-Copper strips & hold fasts :

The item provide for expansion joints in R.C.C. frame structure for internal joints as well as for
exposed joints with the use of necessary copper strip and holdfasts. Copper sheet shall be of
1.25 mm. thick and of 1.25 mm. width the „U‟ shape in the middle. Copper strip shall have hold
fast 3 mm. diameter copper rod fixed to the plate soldered on strip at intervals of about 30 cm.
or as shown in the drawing or as directed. The width of each flange (horizontal side) of the
copper plate to be embedded in the concrete work shall be 25 mm. Depth of „U‟ to be provide in
the expansion joint, in the copper plate shall be of 25 mm.

M-29 Teak Wood :

The teak wood shall be of good quality as required for the item to be executed. When the kind
of wood is not specifically mentioned, good Indian teak wood as approved shall be used.

Teak wood shall generally be free from large, loose, dead or cluster knots, flaws, shakes,
warps, twists bends, or any other defects. It shall generally be uniform in substance and of
stright fibres as far as possible. If shall be free from rot, decay, harmful fungi and other defects
if harmful nature which will affect the strength durability of its usefulness for the purpose for
which it is required. The color shall be uniform as far as possible. Any effort like painting, using
any adhesive or resins materials made to hide the defects shall render the pieces liable to
rejection by the Engineer-in-charge.

All scantlings, planks etc. shall be sawn in straight lines and planes in the direction of grains and
of uniform thickness.
The tolerances in the dimensions shall be allowed at the rate of 1.5 mm. per face to be planed.

First class teak wood : 29.5.1 First class teak wood shall have no individual hard and sound
knots, more than 6 sq. cm. size and the aggregate area of such knots shall not be more than
1% of area of piece. The timber shall be closed grained.

Second Class Teak Wood : 29.6.1 No individual hard and sound knots shall be more than 15
sq. cms. in size and aggregate area of such knots shall not exceed 2% of the area of piece.

M-29 A. Non-teak Wood :

The non teak-wood shall be chemically treated, seasoned as per IS Specifications and of good
quality. The type of wood shall be got approved before collecting the same on site. Fabrication
of wooden members shall be started only after approval.
For this purpose wood of Bio, Kalali, Siras, Behda, Jamun, Sisoo will be used for door frames
where as only Kalali, Siras, Halda, Kalam etc. will be permitted for shutters after proper
seasoning and chemical treatment.The non-teak wood shall be free from large, loose, dead of
cluster knots, flows, shakes, warps, bends or any other defect. It shall be uniform in substance
and of straight fibers as far as possible. If shall be free from rots, decay harmful fungi and other
defects of nature which effect the strength, durability or its usefulness for the purpose for which
it is required. The color of wood shall be uniform as far as possible. The scantlings planks wetc.
shall be sawn in straight lines and planes in the direction of grain and uniform thickness. The
department will use the Agency to produce certificate from Forest Department in event of
Dispute and the decision of the Department shall be final and binding to the contractor. The
tolerance in the dimension shall be allowed as 1.5 mm. per face to be planed.
Signature of Contractor 96
M-30 Wooden flush door shutters (solid core) :

The solid core type flush door shutters shall be decorative or non-decorative type as specified in
the drawing. The size and thickness of the shutter shall be as specified in drawings or as
directed. The timber species for core shall be used as per I.S. 2202 – (Part-I) 1980. The timber
shall be free from decay and insect attack. Knots and knot holes less than half the width of
cross-section of the members in which they occur may be permitted. Pitch pockets, pitch
streaks and harmless pin holes shall be permissible except in the exposed edges of the core
members. The commercial plywood, cross-bands shall conform to I.S. 303-1275.

The face panel of the shutters shall be formed by gluing by the hot press process on both faces
of the core with either plywood or cross-bands and face veneers. The hopping rebating
opening, venetion etc. shall be provided if specified in the drawing.All edges of the door
shutters shall be square. The shutters shall be free from twist or warp in its plane. Both faces of
the shutters shall be sand papered to smooth even texture.The shutters shall be tested for

End immersion test : The test shall be carried out as per I.S. 2202 (part-I) 1980. There shall
be no delamination at the end of the test.

Knife Test : The face panel when tested in accordance with I.S. 1659-1979 shall pass the test.

Glue adhesion test : The flush door shall be tested for glue adhesive test in accordance with
I. S. 2202 (Part-I) 1980. The shutters shall be considered to have passed the test if no
delamination occurs in the glue lines in the plywood and if no single delamination more than 80
mm. in length and more than 3 mm. in depth has occurred in the assembly glue lines between
the plywood face and the style and rail. Delamination at the corner shall be measured
continuously around the corner. Delamination at the knots, knot holes and other permissible
wood defects shall not be considered in assessing the sample.
The tolerance in size of solid core type flush door shall be as under :
In Normal thickness + 1.2 mm. In Normal height + 3 mm.

The thick of the shutters shall be uniform throughout with a permissible variation of not more
than 0.8 mm. when measured at any two points.

M-31 Aluminum doors, windows, ventilators

Aluminum alloy used in the manufacture of extruded window section shall conform to I.S.
designation HEA-WP of I.S. : 733-1975 and also to I.S. Designation WVG-WP of I.S. 1285-1975.
The Section shall be as specified in the drawing and design. The fabrication shall be done as
directed.The hinges shall be cast or extruded aluminum hinge of same type as in window but of
large size.The hinges shall normally be of 50 mm. projecting type. Non-projecting type of
hinges may also be used if directed.The handles of door shall be of specified design. A suitable
lock for the door operatable either from outside or inside shall be provided. In double shutter
door, the first closing shutter shall have concealed aluminum alloy bolt at top and bottom.

31.4 The PVC GASKET OF White of approved quality and Conceal lock of approved quality is to
be utilized.

M-32 Rolling Shutters :

Signature of Contractor 97
32.1 The rolling shutters shall conform to I.S. 6248-1979. Rolling shutters shall be supplied of
specification type with accessories. The size of the rolling shutters shall be specified in the
drawings. The shutters shall be constructed with interlocking lath section formed from cold
rolled steel strips not less than 0.9 mm. thick and 80 mm. wide for shutters up to 3.5 mm.,
width not less than 1.25 mm. thick and 80 mm. wide for shutters 3.5 mm in width and above
unless otherwise specified.

32.2 Guide channels shall be of mild steel deep channel section and of rolled pressed or
built up (fabricated) joint less construction. The thickness of sheet used shall not be less than
3.15 mm.
32.3 Hood covers shall be made of M.S. Sheets not less than 0.92 mm. thickness. For
shutters having width 3.5 Meter and above, the thickness of M.S. Sheet for the hood cover shall
be not less than 1.25 mm.

32.4 The spring shall be of best quality and shall be manufactured from tested high tensile
spring steel wire or strip of adequate strength to balance the shutters in all position. The spring
pipe shaft etc. shall be supported on strong M. S. or malleable C. I. brackets. The brackets shall
be fixed on or fixed on or under the lintel as specified with raw plugs and screws bolts etc.

32.5 The rolling shutters shall be of self rolling type up to 8 Sq. m. clear area without ball
veering and up to 12 Sq. m. clear area with ball bearing. If the rolling shutters are larger, then
gear operated type shutters shall be used.

32.6 The locking arrangement shall be provided at the bottom of shutter at both ends. The
shutters shall be opened from outside.

32.7 The shutters shall be completed with door sustention shafts, locking arrangements,
pulling hooks, handles and other accessories.

M-33 Collapsible Steel Gate :

33.1 The collapsible steel gate shall be in one or two leaves and size as per approved
drawings or as specified. The gate shall be fabricated from best quality mild steel channels, flats
etc. Either steel pulleys or ball bearings shall be provided in every double channel. Unless
otherwise specified the particulars of collapsible gate shall be as under :
(a) Pickets : These shall be of 20 mm. M. S. Channels of heavy sections unless otherwise
shown on drawings. The distance center to center of pickets shall be 12 cms. with an opening
of 10 cms.

(b) Pivoted M. S. Flats shall be 20 mm x 6 mm.

(c) Top and bottom guides shall be from tee or flat iron of approved size.

(d) The fittings like stoppers, fixing hold fasts, locking cleats, brass handles and cast iron
rollers shall be of approved design and size.

M-34 Welded Steel Wire Fabric :


Signature of Contractor 98
34.1 Welded steel wire fabric for general purpose shall be manufactured from cold drawn
steel wire “as drawn” or galvanized steel conforming to I. S. 226-1975 with longitudinal and
transverse wire securely connected at every intersection by a process of electrical resistance
welding and conforming to I.S. 4948-1974. It shall be fabricated and finished in workmanlike
manner and shall be free from injurious defects and shall be rust proof. The type of mesh shall
be oblong or square as directed. The mesh sizes and size of wire for square as well as oblong
welded steel wire fabric shall be as directed. The steel wire fabric in panels shall be in one
whole piece in each panel as far as stock size permit.

M-35 Expanded Metal Sheets :

The expanded metal sheets shall be free from flaws, joints, broken strands, laminations and
other harmful surface. Expanded metal steel sheet shall conform to I. S. 412-1975, except that
blank sheets need not be with guaranteed mechanical properties. The size of the diamond mesh
of expended metal and dimensions of strands (width and thickness) shall be as specified. The
tolerance in nominal weight of expanded metal sheets shall be of + 10 percent.Expanded metal
in panels shall be in one whole piece panel each as far as stock size permit. The expanded
metal sheets shall be coated with suitable protective coating to prevent corrosion.

M-36 Mild Steel Wire (Wire Gauze Jali) : 36.1 Mild steel wire may be galvanized, as
indicated. All finished steel wire shall be well cleanly drawn to the dimensions and size of wire
as specified in item. The wire shall be sound, free from splits, surface flaws, rough jagfied and
imperfect edges and other harmful surface defects and shall conform to I. S. 280-1978.

M-37 Plywood :

37.1 The plywood for general purpose shall conform I. S. 303-1975. Plywood is made by
cementing together thin boards or sheets of wood into panels. There are always an odd number
of layers 3,5,7,9 ply etc. The plies are placed so that grain of each layer is right angle to the
grain in the adjacent layer.

37.2 The advantages of plywood over a single board of the same thickness is the more
uniform strength of the plywood, along the length and width of the plywood and greater
resistance to cracking and splitting with change in moisture content.

37.3 Usually synthetic resins are used for gluing, pherolic resins are usually cured in a hot
press which compresses and simuftacously hers the phes between hot plates which maintain a
temperature of 90 degree. C. to 140 degree C. and a pressure of 11 to 14 Kg. Sq. Cm. on the
wood. The times of heating may be anything from 2 to 60 minutes depending up to
thickness.When water glue are used, the wood absorbs so much water that the finished
plywood must be dried carefully. When synthetic resins are used as adhesive finished plywood
must be exposed to an atmosphere of controlled humidity until the proper amount of moisture
has been absorbed.

37.4 According to I. S. 303-1975 the plywood for general purpose shall be of three grades
namely BWR, WWR and CWR depending upon the adhesives used for bonding and veneers,
and it will be further classified into six types namely AA, AB, AC, BB, BC and CC based on the
quality of the two faces, each face being of three kinds namely, A,B and C. After pressing the

Signature of Contractor 99
finished plywood should be reconditioned to a moisture content not less than 8 percent and not
more than 16 percent.

37.5 Thickness of plywood Boards :

Board Thickness Board Thickness Board Thickness Board Thickness


3 ply 3 mm. 5 ply. 5 mm. 7 ply. 9 mm. 9 ply. 16 mm.
4 mm. 6 mm. 13 mm. 19 mm.
5 mm. 8 mm. 16 mm. 11 ply. 19 mm.
6 mm. 9 mm. 9 ply. 13 mm. 22 mm.
25 mm.

M-38 Glass :

38.1 All glass shall be of the best quality, free from specks, bubbles, smokes, veins, air
holes blisters and other defects. The kind of glass to be used shall be mentioned in the item or
specification or in the special provisions or as shown in detailed drawings. Thickness of glass
panes shall be uniform. The specifications or different kinds of glass shall be as under :

38.2 Sheet Glass :

38.2.1 In absence of any specified thickness or weight in the item or detailed specifications of
the item of work sheet glass shall be weighing 7.5 Kg/Sq. m. for panes up to 600 mm x 600
mm.

38.2.2 For panes larger than 600 mm. x 600 mm. and up to 800 mm. x 800 mm. the glass
weighing not less than 8.75 Kg./Sq. m. shall be used. For bigger panes up to 900 mm. x 900
mm. glass weighing not less than 11.25 Kg./Sq. m. shall be used.

38.2.3 Sheet glass shall be patent flattened glass of best quality and for glazing and framing
purposes shall conform to I. S. : 1761- 1960. Sheet glass of the specified colors shall be used,
if so shown on detailed drawings or so specified. For important building and for panes with any
dimension over 900 mm. plate glass of specified thickness shall be used.

38.3 Plate Glass 38.3.1 When plate glass is specified, it shall be „Polished patent plate
glass‟ of best quality. It shall have both the surface ground flat and parallel and polished to
obtain clear undisturbed vision and reflection. The plate glass shall be of the thickness
mentioned in the item or as shown in the detailed drawing or as specified. In absence of any
specified thickness, the thickness of plate glass to be supplied shall be 6 mm. and a tolerance of
0.20 mm. shall be admissible.

38.4 Obscured Glass : 38.4.1 This type of glass transmits light so that vision is partially or
almost completely obscured. Glass shall be plain rolled, figured, ribbed or fluted or frosted glass
as may be specified as required. The thickness and type of glass shall be as per details on
drawings or as specified or as directed.

38.5 Wired Glass : 38.5.1 Glass shall be with wire netting embedded in a sheet of plate
glass electrically welded 13 mm. Georgian square mesh may be used. Thickness of glass shall
not be less than 6 mm. Wired glass shall be of type and thickness as specified.

Signature of Contractor 100


M-39 Acrylic Sheets :

39.1 Acrylic sheet shall be of thickness as specified in the item and of an specified shape
and size as the case may be. Panels may be flat or curved. It should be light in weight. It shall
be colorless or colored or opaque as specified in the item. Colorless sheet shall be as
transparent as the finest optical glass. Its light transmission rate shall be about 95%,
Transparency shall not be affected for the sheets of larger thickness. It shall be extremely
resistant to sunlight, weather and low temperatures. It shall not show any significant yellowing
or change in physical properties or loss of light transmission over a longer period of use. The
sheet shall be impact resistant also. Sheets should be available in complete range of standard
transparent, translucent and opaque colors. Sheets shall be of such quality that they can be cut,
bent and jointed as desired. Solution for the joints shall be used as per the requirement of
manufacturer.

M-40 Particle board : 40.1 The particle boards used for face panels shall be of best quality
free from any defects. The particle boards shall be made with phenolmaldehyde adhesive. The
particle boards shall conform to I. S. : 3087-1965. “Specification for wood particle board for
general purpose”. The size and the thickness shall be as indicated.

M-41. Expanded polystyrene of framed sty roper slabs : 41.1 The expanded polystyrene
ceiling boards and tiles shall be of approved make and shall be size, thickness, finish and color
as indicated. It shall be of high density and suitable for use as insulating material. The
insulating materials shall be like slab of Thermo Cole etc.

M-42 Resin bonded fiber glass :

42.1 The resin bonded fiber glass tiles, or rolls shall be of approved make and shall be of
sizes, thickness and finish as indicated.

42.2 For test of Mineral wool thermal insulation Blanket I. S. : 3144/1965 shall be followed.

42.3 Insulation wool blanket shall be with following coverings on one or both sides as
indicated.

(1) Bituminised hessain Kraft paper suitable for use in position where moisture has to be
excluded.
(2) Hessian cloth or Kraft paper for keeping out dust.
(3) G. I. wire netting, suitable for surfaces to be plastered over.

M-43 Fixtures and fastenings :

43.1 General :

43.1.1 The fixtures and fastenings, that is butt, hinges, tee and strap hinges, sliding door bolts,
tower bolts, door latch, bath room latch, handles, door stoppers, casement window fasteners,
casement stays and ventilators catch shall be made of the metal as specified in the item or its
specifications.

43.1.2 They shall be of iron, brass, aluminum, chromium plated iron, chromium plated brass,
copper oxidized iron, copper oxidized brass or anodized aluminum as specified.

Signature of Contractor 101


43.1.3 The fixtures shall be heavy, medium or light type. The fixtures and fastenings shall be
smooth finished and shall be such as will ensure case of operation.

43.1.4 The samples of fixtures and fastenings shall be got approved as regards quality and
shape before providing them in position.

43.1.5 Brass and anodized aluminum fixtures and fastenings shall be bright finished

43.2 Holdfasts : 43.2.1 Holdfasts shall be made from mild steel flat 30 cm. length and one
of the hold fasts shall be bent at right angle and two nos. of 6 mm. diameter holes shall be
made in it for fixing it to the frame with screws. At the other end, the holdfast shall be forked
and bent at right angles in opposite directions.

43.3 Butt hinges :

43.3.1 Railway standard heavy type but hinges shall be used when so specified.

43.3.2 Tee and strap hinges shall be manufactured from M. S. Sheet.

43.4Siding door bolts (Aldrops) : 43.4.1 The aldrops as specified in the item shall be used
and shall be got approved.

43.5Tower bolts (Barrel Type) : 43.5.1 Tower bolts as specified in the item shall be used
and shall be got approved.

43.6 Door latch : 43.6.1 The size of door latch shall be taken as the length of latch.

43.7 Bathroom Latch : 43.7.1 Bathroom latch shall be similar to tower bolt.

43.8 Handle : The size of the handles shall be determinded by the inside grip length of the
handles. Handles shall have a base plate of length 50 mm. more than the size of the handle.

43.9 Door Stoppers : 43.9.1 Door stoppers shall be either floor door stopper type or door
catch type. Floor stopper shall be of overall size as specified and shall have a rubber cushion.

43.10 Door Catch : 43.10.1 Door catch shall be fixed at a height of about 900 mm. from the
floor level so that one part of the catch is fitted on the inside of the shutter and the other part
is fixed in the wall with necessary wooden plug arrangements for appropriate fixity. The catch
shall be fixed 20 mm. inside the face of the door for easy operation of catch.

43.11 Wooden Door Stop with hinges : 43.11.1 Wooden door stop of size 100 mm x 60
mm x 40 mm shall be fixed on the door frame with a hinge of 75 mm size and at a height of
900 mm. from the floor level. The wooden door stop shall be provided with 3 coasts of
approved oil paints.

43.12 Casement window Fastener : Casement window fastener for single leaf window
shutter shall be left or right handled as directed.

Signature of Contractor 102


43.13 Casement stays (Straight Peg Stay) : 43.13.1 The stays shall be made from a
channel section having three holes at appropriate position so that the window can be opened
either fully or practically as directed. Size of the stay shall be 250 mm. to 300 mm. as directed.

43.14 Ventilator Catch : 43.14.1 The pattern and shape of the catch shall be as
approved.

43.15 Pivot : 43.15.1 The base and socket plate shall be made from minimum 3 mm. thick
plate and projected pivot shall not be less than 12 mm. diameter and 12 mm. length and shall
be firmly riveted to the base plate in case of iron pivot and in single piece base plate in the case
of brass pivot.

M-44 Paints :

44.1 (A) Oil Paints :

44.1.1 Oil paints shall be of the specified color and shade, and as approved. The ready mixed
paints shall only be used. However, if ready mixed paint or specific shade or tint is not
available, white ready mixed paint with approved strainer will be allowed. In such a case, the
contractor shall ensure that the shade of the paint so allowed shall be uniform.

44.1.2 All the paints shall meet with following general requirements :

all not show excessive setting in a freshly opened full can and shall easily be redispressed with
a paddle to a smooth homogeneous state. The paint shall show no curdling, livering, caking or
color separation and shall be free from lumps and skins.
(ii) The paint as received shall brush easily, posses good leveling properties and show no
running or sagging tendencies.

(iii) The paint shall not skin within 48 hours in a three quarters filled closed container.

(iv) The paint shall dry to a smooth uniform finish free from roughness, grit, unevenness and
other imperfections.

44.1.3 Ready mixed paint shall be used exactly as received from the manufactures and
generally according to their instructions and without any admixtures whatsoever.

44.2 (B) Enamel Paints :

44.2.1 The enamel paint shall satisfy in general requirements as mentioned in specification of
oil paints.
Enamel paint shall conform to I. S. 2933-1975.

M-45 French polish :

45.1 The French polish of required tint and shape shall be prepared with the below mentioned
ingredients and other necessary materials :
(i) Denatured sprit of approved quality (ii) Chandras (iii) Shellac (iv) Pigment.

45.2 The French polish so prepared shall conform to I. S. : 348-1968.

Signature of Contractor 103


M-46 Marble chips for marble mosaic terrazzo :

46.1 The marble chips shall be of approved quality and shades. It shall be hard, sound,
dense and homogeneous in texture with crystalline and coarse grains. It shall be uniform in
color and free from stains, cracks decay and weathering.

46.2 The size of various colors of marble chips ranging from the smallest up to 20 mm.
shall be used where the thickness of top wearing layer is 6 mm. size. The marble chips of
approved quality and colors only as per grading as decided by the Engineer-in-charge shall be
used for marble mosic tiles or works

46.3 The marble chips shall be machine crushed. They shall be free from foreign matter,
dust etc. Except as above, the cips shall conform to I. S. : 2114-1962.

M-47 Flooring Tiles :

47.1 (A) Plain Cement Tiles :

47.1.1 The plain cement tiles shall be general purpose type. These are the tiles in the
manufacturer of which no pigments are used. Cement used in the manufacture of tiles shall be
as per Indian Standards.

47.1.2 The tiles shall be manufactured from a mixture of cement and natural aggregates by
pressure process. During manufacture, the tiles shall be subjected to a pressure of not less than
140 Kg/Sq. Cm. The proportion of cement to aggregate in the backing of the tiles shall be not
less than 1:3 by weight. The wearing face though the tiles are of plain cement, shall be
provided with stone chips of 1 to 2 mm. size. The proportions of cement to the marble chips
aggregate in the wearing layer of the tiles shall be three parts of cement to one part chips by
weight.

The minimum thickness of wearing layer shall be 3 mm. The color and texture of wearing layer
shall be uniform throughout its face and thickness. On removal from mould, the tiles shall be
kept in moist conditions continuously at least for seven days and subsequently, if necessary, for
such long period as would ensure their conformity to requirements of I. S. : 1237-1980
regarding strength resistance to wear and water absorption.

47.1.3 The wearing face of the tiles shall be plain, free from projections, depressions and
cracks and shall be reasonably parallel to the back face of the tile. All angles shall be right and
all edges shall be right and all edges shall be sharp and true.

47.1.4 The size of tiles shall generally be square shape 24.85 Cm. x 24.85 Cm. or 25 Cm. x 25
Cm. The thickness of tiles shall be 20 mm.

47.1.5 Tolerance of length and breadth shall be plus or minus one millimeter. Tolerance on
thickness shall be plus 5 mm.

47.1.6 The tiles shall satisfy the tests as regards transverse strength, resistance to wear and
water absorption as per I. S. : 1237-1980.

Signature of Contractor 104


47.2 (B) Plain Colored Tiles :

47.2.1 These tiles shall have the same specification as per plain cement tiles as per (A) above
except that they shall have a plain wearing surface wherein pigments are use. They shall
conform to I. S. 1237-1980.

47.2.2 The pigment used for coloring cement shall not exceed 10 percent by weight of cement
used in the mix. The pigments, synthetic or otherwise, used for coloring tiles shall have
permanent color and shall not contain materials detrimental to concrete.

47.2.3 The color of the tiles shall be specified in the item or as directed.

47.3 (C) Marble mosaic tiles :

47.3.1 These tiles have the same specifications as per plain cement tiles except the
requirements as stated below :

47.3.2 The marble mosaic tiles shall conform to I. S. 1237-1980. The wearing face of the tiles
shall be mechanically ground and filled. The wearing face of tiles shall be free projections,
depressions and cracks and shall be reasonably parallel to the back face of the tiles. All angles
shall be right angles and all edges shall be sharp and true.

47.3.3 Chips used in the tiles be from smallest up to 20 mm. size. The minimum thickness of
wearing layer of tiles shall of 6 mm. For pattern of chips to be used on the wearing face, a few
samples with or without their full size photographs as directed shall be presented to the
Engineer-in-charge for approval.

47.3.4 Any particular samples, if found suitable shall be approved by the Engineer-in-charge or
he may ask for a few more samples to be prepared indicating roughly the particular sized chips
to be more or less in the samples presented. The samples have to be made but the contractor
till a suitable sample is finally approved for use in the work.

The contractor shall ensure that the tiles supplied for the work shall be in conformity with the
approved sample only, in terms of its dimensions, thickness of backing layer and wearing
surface, materials, ingredients, color shade, Chips, distribution etc. required.

47.3.5 The tiles shall be prepared from cement conforming to Indian Standards or colored
Portland cement generally depending upon the color of tiles to be sued or as directed.

47.4 (D) Chequered Tiles :


47.4.1 Chequered tiles shall be plain cement tiles or marble mosaic tiles. The former shall have
the same specification as per (A) above and the latter as per marble mosaic tiles as per (C)
except as mentioned below :

47.4.2 The tiles shall be of nominal size of 250 mm. x 250 mm. or as specified. The center to
center distance of chequer shall not be less than 25 mm. and not more than 50 mm. The
overall thickness of the tile shall be 22 mm.
Signature of Contractor 105
47.4.3 The grooves in the chequers shall be uniform and straight. The depth of the grooves
shall not be less than 3 mm. The chequered shall be plain, colored or mosaic as specified. The
thickness of the upper layer measured from the top of the chequers shall not be less than 6
mm. The tiles shall be given the first grinding with machine before delivery to site.
47.4.4 Tiles shall conform to relevant I. S. 1237-1980.

47.5 (E) Chequered Tiles for Stair cases :


47.5.1 The requirements of these tiles shall be the same as chequered as per (D) above except
in following respects;
(1) The length of a tile including nose shall be 330 mm.
(2) The minimum thickness shall be 28 mm.
(3) The nosing shall have also the same wearing layer as at the top.
(4) The nosing edge shall be rounded.
(5) The front portion of the tile for a minimum length of 75 mm. from and including the nosing
shall have grooves running parallel to nosing and at center not exceeding 25 mm. Beyond that
the tiles shall have normal chequer pattern.

M-48 Rough Kotah Stone :

48.1 The kotah stones shall be hard, even, sound, and regular in shape and generally uniform
in color. The color of the stone shall generally be green. Brown color stones shall not be
allowed for use. They shall be without any soft veins, cracks or flows.

48.2 The size of the stones to be used for flooring shall be of size 600 mm x 600 mm and / or
size 600 mm x 450 mm as directed. However smaller sizes will be allowed to be used to the
extent of maintaining required pattern. Thickness shall be as specified.

48.3 Tolerance of minus 30 mm. on account of chisel dressing of edges shall be permitted for
length as well as breadth. Tolerance in thickness shall be + 3 mm.

48.4 The edges of stones shall be truly chiseled and table rubbed with coarse sand before
paving. All angles and edges of the stone shall be true, square and free from chipping and the
surface shall be true and plain.

48.5 When machine cut edges are specified, the exposed edges and the edges at joints shall be
machine cut. The thickness of the exposed machine cut edges shall be uniform.

M-49 Polished Kotah Stones

49.1 Polished kotah stone shall have the same specifications as per rough kotah stone except
as mentioned below :

49.2 The stones shall have machine polished smooth surface. When brought on site, the
stones shall be single polished or double polished depending upon its use. The stones for
Signature of Contractor 106
paving shall generally be single polished. The stones to be used for dedo, skirting, platforms,
sink, veneering, sills, etc. where machine polishing after the stones are fixed in site is not
possible, shall be double polished.

M-50 Dholpur Stone Slab :

50.1 Dholpur stone slab shall be of best quality as approved by the Engineer-in-charge. The
stone slab shall be even, sound and durable, regular in shape and of uniform color.

50.2 The size of the stone shall be specified in the item or detailed drawings or as approved
by the Engineer-in-charge. The thickness of the stone shall be as specified in the item of work
with the permissible tolerance of plus or minus 2 mm. The provisions in respect of polishing as
for polished Kotah stone shall apply to polished Dholpur stone also. All angles and edges of the
face of the stone slab shall be fine chiseled or polished as specified in the item of work and all
the four edges shall be machine cut.
All angle and edges of the stone slab shall be true and plane.

50.3 The sample of stone shall be got approved from the Engineer-in-charge for shade and
tint for a particular work. It shall be ensured that the stones to be used in a particular work
shall not differ much in shade or tint from the approved sample.

M-51 Marble Slab :

51.1 Marble slab shall be white or of other color and of best quality as approved by the
Engineer-in-charge.

51.2 Slabs shall be hard, uniform and homogeneous in texture. They shall have even
crystalline grain and free from defects and cracks. The surface shall be machine polished to an
even and perfectly plant surface and edges machine cut true and square. The rear face shall be
rough to provide key for the mortar.

51.3 Marble slabs with natural veins, if selected shall have to be laid as per the pattern given
by the Engineer-in-charge. Size of the slab shall be minimum 450 mm x 450 mm. and
preferable 600 mm x 600 mm. However, smaller sizes will be allowed to be used to the extent
of maintaining required pattern.

51.4 The slab shall not be thinner than the specified thickness at its thinnest part. A few
specimen of finished slab to be used shall be deposited by the Contractor in the office for
reference.

51.5 Except as above the marble slabs shall conform to I. S. 1130-1969.

M-52 Granite Stone Slab :

52.1 Granite shall be of approved color and quality. The stone shall be hard, even, sound
regular in shape and generally uniform in color. It shall be without any soft veins, cracks of
flows.

52.2 The thickness of the stone shall be as specified in the items

Signature of Contractor 107


52.3 All exposed face shall be double polished to tender truly smooth and the even
reflecting surface. The exposed edges and corners shall be rounded off as directed. The
exposed edges shall be machine cut and shall have uniform thickness.

M-53 P.V.C. Flooring :

53.1 P.V.C. Sheets for P.V.C. floor covering shall be of homogeneous flexible type,
conforming to I. S. 3452-1966. The P.V.C. covering shall neither develop any toxic effect while
put to use nor shall give off any disagreeable odour.

53.2 Thickness of flexible type covering tiles shall be as specified in the description of the
item.

53.3 The flexible type shall be backed with hessain or other woven fabric. The following
tolerances shall be applicable on the nominal dimension of the sheet rolls or tiles :

Thickness + 0.15 mm.


Length or Width :

1. 300 mm. + 0.20 mm. 3. 9.00 mm. square + 0.30 mm.


square tiles tiles
2. 600 mm. “ + 0.40 mm. 4. Sheets and rolls + 0.10 percent

53.4 Adhesive :

53.4.1 The adhesive for PVC flooring shall be of the type and make recommended by the
manufacturers of PVC sheets/tiles.

M-54 Facing tiles :

54.1 The facing tiles (burnt clay facing bricks) shall be free from craks, flaws and nodules of
free lime. They shall be thoroughly burnt and shall have plane rectangular faces with parallel
sides and sharp straight right edgled faces. The texture of the finished surface that will be
exposed when in place, shall conform to an approved sample consisting not less than four
stretcher bricks each representing the texture desired. The facing tiles tiles shall have a
pleasing appearance, sufficient resistance to penetration by rain and greater durability than
common bricks. The tiles shall conform to I. S. 2691-1972.

54.2 The standard size of facing brick tiles shall be 19x9x4 cms. The facing bricks tiles shall
be provided with frog which shall conform to I. S. 1077-1976.

54.3 The permissible tolerance in dimensions specified above shall be as follows :

Size Tolerance for

1st class Brick 2nd class Brick


19 cm. + 6 mm. + 10 mm.
9 cm. + 3 mm. + 7 mm.
Signature of Contractor 108
4 cm. + 1.5 mm. + 3 mm.

54.4 The tolerance for distortion or warp age of face or edges of individual brick from a
plane surface and from a straight line respectively shall be as follows :

Facing dimensions Permissible Tolerance


Max. below 19 cms. Max.2.5mm.
-do- above 19cm. Max. 3.0 mm.

54.5 The average compressive strength obtained as a sample of five tiles when tested in
accordance with the procedure laid as per I.S. 1077-1976 shall be not less than 175 Kg/Sq. Cm.
The average compressive strength of any individual bricks shall be not less than 160 Kg./Sq.
Cm.

54.6 The average water absorption for five bricks tiles shall not exceed 12 percent of
average weight of brick before testing. The absorption for each individual bricks shall not
exceed 25 percent.

54.7 The bricks tiles when tested in accordance with I.S. 1077-1976, the rate of
efflorescence shall not be more than Slightly effloresced.

M-55 A White glazed tiles :

55.1 The tiles shall be of best quality as approved by the Engineer-in-charge. They shall be
flat and true to shape. They shall be free from cracks, crazing, spots, chipped edges and
corners. The glazing shall be of uniform shade.

55.2 The tiles shall be nominal size of 200 mm. x 300 mm. unless otherwise specified. The
maximum variation from the stated sizes, other than the thickness of tile, shall be plus or minus
1.5 mm. The thickness of tile shall be 6 mm. Except as above the tiles shall conform to I. S.
777-1970.

M-55B Vitrified tiles:-

55.1B The tiles shall be nominal size of 24” Inch x 24” Inch. unless otherwise specified
55.2B The other specification shall be as specified in glaze tile shall be applicable.
55.3B The measurement shall be taken per Sq. Meter of actual work done as per IS.

M-55 C Skirting for tiles

55.1C The other specification shall be as specified in glaze tile as well as vitrified tiles shall be
applicable
55.2C The measurement shall be for item of skirting per Rmt for item of skirting and height of
same shall be 75mm or 100mm as directed.

M-56 Galvanished iron pipes and fittings : 56.1 Galvanised iron pipe shall be of the
medium type and of required diameter and shall comply with I.S. 1239-1979. The specified
diameter of the pipes shall refer to the inside diameter of the bore. Clamps, screw and all
galvanized iron fittings shall be of the standard „R‟ or equivalent make.

Signature of Contractor 109


M-57 Bib cock and stop cock :

57.1 A bib cock is a draw off tap with a horizontal inlet and free outlet. A stop cock is a
valve with a suitable means of connection for insertion in a pipe line for controlling or stopping
the flow.

57.2 They shall be of screw down type and of brass chromium plated and of diameter as
specified in the description of the item. They shall conform to I.S. 781-1977 and they shall be of
best Indian make. They shall be polished bright.\

57.3 The minimum finished weight of bib cock and stop cock shall be as given below :

Diameter Bib cock Stop cock Diameter Bib cock Stop cock

8 mm. 0.25 Kg. 0.25 kg. 15 mm. 0.40 Kg. 0.40 Kg.
10 mm. 0.30 kg. 0.35 kg. 20 mm. 0.75 kg. 0.75 kg.

M-58 Gun metal wheel valve : 58.1 The gun metal wheel valve be of approved quality.
These shall be gun metal fitted with wheel and shall be of gate valve opening full way and of
the size as specified. These shall conform to I. S. 778-1971.

M-59 White glazed porcelain wash basin :

59.1 Washbasin shall be of white porcelain first quality best Indian make and it shall conform
to I. S. 2566 (Part-IV) 1972 and I. S. 771-1979.The size of the washbasin shall be as specified
in the item, Washbasin shall be of one piece construction with continued over-flow
arrangements. All internal angles shall be designed so as to facilities cleaning. Washbasin shall
have single tap hole or two holes as specified. Each basin shall have a circular waste hole which
is either rebated or beveled internally with 65 mm. diameter at top and 10 mm. depth to suit
the waste fitting. The necessary stud slot to receive the bracket on the underside of the basin
shall be provided. Basin shall have an internal soap holder recess which shall fully drain into the
bowl.

59.2 White glazed pedestal of the quality and color as that of the basin shall be provided
where specified in the item. It shall be completely recessed at the back for reception of supply
and wash pipe. It shall be capable of supporting the basin rigidly and adequately and shall be
so designed as to make the height from floor to top of the rim of basin 750 mm. to 800 mm. as
directed.

M-60 European type water closet /with low level flushing :

60.1 The European type water closet shall be white glazed porcelain first quality and shall be
of wash down type conforming to I. S. 2556-1973 and I. S. 771-1979.

60.2 „S‟ trap shall be provided as required with water seal not less than 50 mm. The solid
plastic sent and cover shall be of the best Indian make conforming to I.S. 2548-1980. They
shall be made of moulded synthetic materials which shall be tough and hard with high

Signature of Contractor 110


resistance to solvents and shall be free from blisters and other surface defects and shall have
chromium plated brass hinges and rubber buffer of suitable size.

M-61 Orissa type water closet : 61.1 The specification of Orissa type white glazed water
closet of first quality shall conform to I. S. 2556 (Part-III) 1981 and relevant specification of
Indian type water closet except that pan will be with the integral squatting pan of size 580 mm.
x 440 mm. with raised footrest.

M-62 Indian type water closet :

62.1 The Indian type white glazed water closet of first quality shall be of size as specified in
the item and conforming to I. S.771-1979 and I. S. 2556 (Part-II) 1981. Each pan shall have
integral flushing ring of suitable type with adequate number of holes around as directed to have
satisfactory flushing. It shall also have an inlet at back or front for connecting flush pipe as
directed. The inside of the bottom of the pan shall have sufficient slope from the front towards
the outlet and surface shall be uniform and smooth. Pan shall be provided with 100 mm.
diameter „P‟ or „S‟ trap with approximately 50 mm. water seal and 50 mm. diameter vent horn.

M-62.A Foot Rests : 62-A-1 A pair of white glazed earthen ware rectangular foot rests of
minimum size 250 mm. x 130 mm. 20 mm. shall be provided with water closet.

M-63 Glazed Earthen Ware Sink :

63.1 The glazed earthenware sink shall be specified size, color and quality. The sink shall
conform to I. S. 771 Part-II-1979. The brackets for sinks shall conform to I. S. 775-1970.

63.2 The pipes shall conform to I. S. 1239-Part-I 1973 and I. S 404-1962 for steel and lead
pipes respectively 32 mm. brass waste coupling of standard pattern with brass chain and rubber
plug shall be provided with sink.

M-64 Glazed earthen ware Lipped type flat back urinal/corner type urinal : 64.1 The
lipped type urinal shall be flat back or corner type as specified in the item and shall conform to
I. S. 771-1979. It shall be of Indian make and size as specified and approved by the Engineer-
in-charge. The flat back or corner type urinal must be of 1st quality free from any defects,
cracks, etc.

M-65 Low level enamel flushing tank : 65.1 The low level enamel flushing tank shall be of
15 liters capacity. It shall conform to I. S. 774-1971. The flushing cistern shall be of best quality
and free from any defects. The flushing tank shall have outlet 32 mm. diameter. The outlet
shall be connected with W. C. Pan by lead pipe or P.V.C. pipe as specified. The flushing tank
shall be provided with inlet and outlet for fixing G. I. inlet pipes and over-flow pipes. The
flushing cistern shall be provided with chromium plated handle for flushing. The flushing tank
shall be provided with bracket of cast iron so that it can be fixed on wall at specified height.
The brackets shall conform to I. S. 775-1970.

M-66 Cast iron flushing cistern : 66.1 The cast iron flushing cistern shall be of 15 liters
capacity. It shall conform to I. S. 774-1971. The flushing cistern shall be of best quality free
from any defects. The flushing cistern shall have outlet of 32 mm. diameter. The outlet shall be
connected to lead pipe of 32 mm. diameter. The lead pipe shall conform to I. S. 404 (Part-I)
1962. For fixing G. I. inlet pipes and overflow pipe 20 mm. dia inlet and outlet shall be
Signature of Contractor 111
provided. The flushing cistern shall be provided with galvanized iron chain pull of sufficient
length and shall be got approved from the Engineer-in-charge. The cast iron flushing cistern
shall be painted with one coat of anticorrosive paint and two coats of paint. The flushing cistern
shall be fixed on two C.I. brackets. The C. I. brackets shall conform to I. S. 775-1970.

M-67 Flush cock : 67.1 Half turn flush cask (Heavy weight) shall be of gun metal chromium
plated of diameter as specified in the description of the item. The flush cock shall conform to
relevant Indian Standard.

M-68 Cast iron pipes and fittings :

68.1 All soil, waster, vent and antisyphonage pipes and fittings shall conform to I. S. 1729-
1964. The pipe shall have spigot and socket ends with head on spigot end. The pipes and
fittings shall be true to shape, smooth, cylindrical, their inner and outlet surfaces being as
nearly as practicable concentric. They shall be sound and nicely cast and shall be free from
cracks. Laps, pinholes or other imperfection and shall be neatly dressed and carefully fettled.

68.2 The end of pipes and fittings shall be reasonable square to their axis.

68.3 The sand cast iron pipes shall be of the diameter as specified in the description and
shall be in lengths of 1.5 M, 1.8 M and 2 m. including socket ends of the pipe unless shorter
lengths are either specified or required at junctions etc. The pipes and fittings shall be supplied
without ears unless specified or directed otherwise.

Tolerances :

68.4.1 The Standard weight and thickness of pipes shall be as shown in the following table : A
tolerance up to minus 10 percent may however be allowed against these standard weights.

Sr. No. Nominal Thickness Overall Weight of Pipe


dia. of bore excluding ears
1.5 m long 1.8 m. 2 m. long
Long
1. 75 mm. 5.0 mm. 12.83 Kg. 16.52 Kg. 18.37 Kg.
2. 100 mm. 5.0 mm. 18.14 Kg. 21.67 kg. 24.15 Kg.

68.4.2 A tolerance up to minus 15 percent in thickness and 20 mm. in length will be allowed.
For fittings tolerance in lengths shall be plus 15 mm. and minus 10 mm.

68.4.3 The thickness of fittings and their socket and spigot dimensions shall conform to the
thickness and dimensions specified for the corresponding sizes of straight pipes. The tolerances
in weights and thickness shall be the same as for straight pipes.

M-69 Nahni Trap :

69.1 Nahni trap shall be of cast iron and shall be sound and free from porosity or other
defects which affect serviceability, The thickness of the base metal shall not be less than 6.5
mm. The surface shall be smooth and free from craze, ships and other flaws or any other kind
of defects which affect serviceability. The size of nahni trap shall be as specified and shall be of
self cleansing design.
Signature of Contractor 112
69.2 The nahni trap shall be of quality approved by the Engineer-in-charge and shall
generally conform to the relevant Indian Standards

69.3 The nahni trap provided shall be with deep seal, minimum 500 mm. except at places
where trap with deep seal cannot be accommodated. The cover shall be cast iron. Perforated
cover shall be provided on the trap of appropriate size.
M-70 Gully Trap :

70.1 gully trap shall conform to I. S. 651-1980. It shall be sound, free from defects such as
fire cracks. The glaze of the traps shall be free from crazing. They shall give a shart clear note
when struck with light hammer, There shall be no broken blisters.
70.2 The size of the gully trap shall be as specified in the item

70.3 Each gully trap shall have one C. I. grating of square size corresponding to the
dimensions of inlet of gully trap. It will also have a water tight C. I. cover with frame inside
dimensions 300 mm. x 300 mm. the cover with frame inside dimension, 300 mm. x 300 mm.
the cover weighing not less than 4.53 Kg. and the frame not less than 2.72 Kg. The grating
cover and frame shall be of sound and good casting and shall have truly square machined
seating faces.

M-71 Glaze Stone Ware pipe and fitting :

71.1 The pipes and fittings shall be of best quality as approved by the Engineer-in-charge.
The pipe shall be best quality manufactured from stone-ware of fire clay, salt glazed thoroughly
burnt through the whole thickness of a close even texture, free from air blows, fire blisters,
crack and other imperfections, which effect the serviceability. The inner and outer surfaces shall
be smooth and perfectly glazed. The pipe shall be capable to withstand pressure of 1.5 m. lead
without showing sign of leakage. The thickness of the wall shall not be less than 1/12th of the
internal dia. The depth of socket shall not be less than 38 mm. The socket shall be sufficiently
large to allow a joint of 1 mm. around the pipe.

71.2 The pipes shall generally conform to relevant I. S. 651-1980.

M-72 Wall Peg Rail :

72.1 The aluminum wall peg rail shall have three aluminum pegs of approved quality and
size. It shall be fixed on teakwood plank of size 450 mm. x 75 mm. x 20 mm. The teakwood
shall be French polished or oil painted as specified.

M-73 G. I. Water Spot :

73.1 The G. I. pipes of 40 mm. dia shall be of medium quality and specials shall be of „R‟
brand or equivalent brand of best approved quality.

73.2 The pipe shall have length as required for the thickness of wall in which it is fixed and at
the outside end tee and bend cut at half the length shall be provided and at other end coupling
shall be provided to have better fixing. The water spout shall be provided as per detailed
drawing or as directed.

Signature of Contractor 113


M-74 Asbestos Cement Pipe (A. C. Pipe) :

74.1 The asbestos cement pipe of diameter as specified in the description of the item shall
conform to I. S. 1626-1980. Specials like bends, shoes cowls, etc. shall conform to relevant
Indian Standards. The interior of pipe shall have a smooth finish, regular surface and regular,
internal diameter. The tolerance in all dimensions shall be as per I. S. 1626-Part-I 1980.

M-75 Crydon Ball Valve : 75.1 Ball valve of screwed type including polthylene float and
necessary lever etc. shall be of the size as mentioned in the description of item and shall
conform to I. S. 1703-1977.

M-76 Bitumen Felt For Water Proofing And Damp Proofing : 76.1 Bitumen felt shall be
on the fiber bases and shall be type 2, self finished grade-2 and shall conform to I. S. 1322-
1970.

M-77 Selected Earth :

77.1 The selected earth shall be that obtained from excavated material or shall have to
brought from outside as indicated in the item. If item does not indicate anything, the selected
earth shall have to be brought from outside.

77.2 The selected earth shall be good yellow soil and shall be got approved from the
Engineer-in-charge. In no case black cotton soil or similar expansive and shrinkable soil shall be
used. It shall be clean and free from all rubbish and perishable materials, stones or brick bats.
The clods shall be broken to a size of 50 mm. or less, Contractor shall make his own
arrangement at his own cost for land for borrowing selected earth. The stacking of material
shall be done as directed by the Engineer-in-charge in such a way as not to interfere with any
constructional activities and in proper stacks.

77.3 When excavated materials is to be used, only selected stuff got approved from the
Engineer-in-charge shall be used. It shall be stacked separately and shall comply with all the
requirements of selected earth mentioned above :

M-78 Barbed Wire :

78.1 The barbed wire shall be of galvanized steel and it shall generally conform to I. S. 278-
1978. The barbed wire shall be of type-I whose nominal diameter for line wire shall be 2.5 mm.
and point wire 2.24 mm. The nominal distance between two bars shall be 75 mm. unless
otherwise specified in the item. The barbed wire shall be formed by twisting together two line
wires, one containing the barbs. The size of the line and point wires and barb spacings shall be
as specified above. The permissible deviation from the nominal diameter of the line wire and
point wire shall not exceed + 0.08 mm.

78.2 The barbs shall carry four points shall be formed by twisting two point wires, each two
turns, lightly round one line wire, making altogether four complete turns. The barbs shall be so
finished that the four points are set and locked at right angles to each other. The barbs shall
have a length of not less than 13 mm. and not more than 18 mm. The point shall be sharp and
cut at angle not greater than 35 degree of the axis of the wire forming the barbs.

Signature of Contractor 114


78.3 The line and point wire shall be circular section free from scale and other defects and
shall be uniformly galvanized. The line wire shall be in continuous length and shall not contain
any weld other than those in the rod before it is drawn. The distance between two successive
splices shall not be less than 15 meters.

78.4 The lengths per 100 Kg. of barbed wire I. S. type I shall be as under
Nominal 1000 meter Minimum 834 Meter Maximum 1066 Meter.

DETAILED SPECIFICATIONS

Item No.-1 (For Schedule - B)

Excavation for foundation up to 1.5 m depth including sorting out and stacking of
useful materials and disposing of the excavated stuff up to 50 meter lead.
(A) Loose or soft soil

1.0 General : 1.1 Any soil which generally yields to the application of pickaxes and shovels,
phawaras, rakes or any such ordinary excavating implement or organic soil, gravel, silt, sand
turf loam, clay, peat etc. fall under this category.

2.0 Clearing the site : 2.1 The site on which the structure is to be built shall be cleared and
all obstructions, loose stone, materials and rubbish of all kind, bush, wood and trees shall be
removed as directed. The materials so obtained shall be properly of the Government and be
conveyed and stacked as directed within 50 M. lead. The roots of the trees coming in the sides
shall be cut and coated with a hot asphalt.

2.2 The rate of site clearance is deemed to be included in the rate of earth work for which no
extra will be paid.

3.0 Setting out : After clearing the site, the centerlines will be given by the Engineer-in-
charge. The contractor shall assume full responsibility for alignment, elevation and dimension
of each and all parts of the tractor shall assume full responsibility for alignment levation and
dimension of each and all parts of the work. Contractor shall supply laborers, materials, etc.
required for setting out the reference marks and bench marks and shall maintain them as long
as required and directed.

4.0 Excavation : The excavation in foundation shall be carried out in true line and level and
shall have the width and depth as shown in the drawings or as directed. The contractor shall
do the necessary shoring and shutting or providing necessary slopes to a safe angle, at his own
cost. The payment for such precautionary measures shall be paid separately if not specified.
The bottom of the excavated area shall be 1evelled both longitudinally and transversely as
directed by removing and watering as required. No earth filling will be allowed for bringing
it to level, if by mistake or any other reason excavation is made deeper or wider that shown on
the plan or directed. The extra depth or width shall be made up with concrete of same
proportion as specified for the foundation concrete at the cost of the contractor. The
excavation up to 1.5 m. depth shall be measured under this item.

Signature of Contractor 115


5.0 Disposal of the excavated stud :

5.1 The excavated stuff of the selected type shall be used in filling the trenches and plinth or
leveling the ground in layers including ramming and watering etc.

5.2 The balance of the excavated quantity shall be removed by the contractor from the site of
work to a place as directed with lead up to 50 M. and all lift.
6.0 Mode of measurement and payment :

6.1 The measurement of excavation in trenches for foundation shall be made according to the
sections of trenches shown on the drawing or as per sections given by the Engineer-in-charge.
No payment shall be made for surplus excavation made in excess of above requirements or due
to slopping back as found necessary on account of conditions of soil and requirements of safety.

6.2 The rate shall be for a unit of one cubic meter.

2.0 General :

Grade of concrete Total quantity of dry Proportion of fine Quantity of water


aggregate by volume per 50 aggregate to coarse per 50 Kgs. of
kgs. Of cement to be taken aggregate cement maximum
as the sum of individual of
fine and coarse aggregates,
1 maximum
2 3 4

M-100 (1 : 3 : 6) 300 Liters Generally 1 : 2 for 34 liters


fine aggregate to
coarse aggregate
by volume but
subject to and
upper limit of 1:1
1/2 and lower limit
1:3

M-150 (1 : 2 : 4) 220 “ 32 “
M-200 (1 : 1 1/2 : 160 “ 30 “
3)
M-250 (1 : 1 : 2) 100 “ 27 “

2.1 The concrete mix is not required to be designed by preliminary tests. The proportion of the
concrete mix shall be 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm.
nominal size) by volume. Concrete work shall have exposed concrete surface or as specified in
the item.

2.2 The designation ordinary M-100, M-150, M-200, M-250 specified as per I. S. Corresponding
approximately to 1 : 3 : 6, 1 : 2 : 4, 1 ½ : 3 and 1 : 1 : 2 nominal mix of ordinary concrete by
volume respectively. The mimimum quantity of cement used in cement concrete M-

Signature of Contractor 116


150 shall be 320 Kg per Cum in Plain Cement concrete / Reinforced Cement
Concrete ( Ordinary or Controlled).

2.3 The ingredients required for ordinary concrete containing one beg of cement of 50 Kg. by
weight (0.0342 Cu. M.) for different proportions of mix shall be as under :

2.4 The water cement ratio shall not more than those specified in the above table. The cement
content of the mix specified in the Table shall be increased if the quantity of water in a mix has
to be increased to overcome the difficulties of placement and compaction so that the water-
cement-ratio specified in the Table is not exceeded.
2.5 Workability of the concrete shall be controlled by maintaining a water-cement-ratio that
is bound to give a concrete mix which is just sufficiently wet to be placed and compacted
without difficulty with the means available.

2.6 The maximum size of coarse aggregate shall be as large as possible within the limits
specified but in no case greater than one fourth of the minimum thickness of the member,
provided that the concrete can be placed without difficulty so as to surround all reinforcement
thoroughly and to fill the corners of the form.

2.7 For reinforced concrete work, coarse aggregates having a nominal size of 20 mm. are
generally considered satisfactory.

2.8 For heavily reinforced concrete members as in the case of ribs of main beems, the
nominal maximum size of coarse aggregate should usually be restricted to 5 mm. less than the
minimum clear distance between the main bars, or 5 mm. less than the minimum cover to the
reinforcement whichever is smaller.

2.9 Where the reinforcement is widely spaced as in solid slabs, limitations of size of the
aggregate may not be important and the nominal maximum size may sometimes be as great as
or greater than the minimum cover.

2.10 Admixture may be used in concrete only with approval of Engineer-in-charge upon the
evidence that with the passage of time, neither the compressive strength of concrete is reduced
nor are other requisite qualities of concrete and steel impaired by the use of such admixtures.

3.0 Workmanship :

3.1 Proportioning : proportioning shall be done by volume, except cement which shall be
measured in terms of bags of 50 Kg. weight. The volume of one such bag being taken as
0.0342 Cu. Meter Boxes of suitable sizes shall be used for measuring sand aggregate. The size
of the boxes (internal) shall be 35 cms. x 25 cms. and 40 cms. deep. While measuring the
aggregate and sand, the box shall be filled without shaking ramming or hammering. The
proportioning of sand shall be on the basis of its dry volume and in case of damp sand,
allowances for bulk age shall be made.

3.2 Mixing :

3.2.1 For all work. Concrete shall be mixed in a mechanical mixer which along with other
accessories shall be kept in first class working condition and so maintained throughout the
construction. Measured quantity of aggregate, sand, cement required for each batch shall be

Signature of Contractor 117


poured into the drum of the mechanical mixer while it is continuously running. After about half
a minute of dry mixing, measured quantity of water required for each batch of concrete mix
shall be added gradually and mixing continued for another one and a half minute. Mixing shall
be continued till materials are uniformly distributed and uniform color of the entire mass is
obtained and each individual particle of the coarse aggregate shows complete coating of mortar
containing its proportionate amount of cement. In no case shall
the mixing be done for less than 2 minutes after all ingredients have been put into the mixer.

3.2.2 When hand mixing is permitted by the Engineer-in-charge for small jobs or for certain
other reasons, it shall be done on the smooth watertight platform large enough to allow
efficient turning over the ingredients of concrete before and after adding water. Mixing platform
shall be so arranged that no foreign materials gets mixed with concrete nor does the mixing
water flow out. Cement in required number of bags shall be placed in a uniform layer on top of
the measured quantity of fine and coarse aggregate, which shall also be spread in a layer of
uniform thickness on the mixing platform. Dru coarse and fine aggregate and cement shall then
be mixed thoroughly by turning over to get a mixture to uniform color. Specified quantity of
water shall then be added gradually through a rose-can and the mass turned over till a mix of
required consistency is obtained. In hand mixing, quantity of cement shall be increased by 10
percent above that specified.

3.2.3 Mixers which have been out of use for more than 30 minutes shall be throughly cleaned
before putting in a new batch. Unless otherwise agreed to by the Engineer-in-charge the first
batch of concrete from the mixture shall contain only two thirds of normal quantity of coarse
aggregate. Mixing plant shall be thoroughly cleaned before changing from one type of cement
to another.

3.3 Consistency : 3.3.1 The degree of consistency which shall depend upon the nature of
the work and methods of vibration of concrete, shall be determined by regular slumps tests in
accordance with I. S. 1199-1959. The slumps of 10 mm. to 25 mm. shall be adopted when
vibrators are used and 80 mm. when vibrators are not used.

3.4 Inspection :

3.4.1 Contractor shall give the Engineer-in-charge due notice before placing any concrete in
the forms to permit him to inspect and accept the false work and forms as to their strength,
alignment, and general fitness but such inspection shall not relive the contractor of his
responsibility for the safety of men, machinery, materials and for results obtained. Immediately
before concreting, all forms shall be thoroughly cleaned.

3.4.2 Centering design and its erection shall be got approved from the Engineer-in-charge.
One carpenter with helper shall invariably be kept present throughout the period of concreting.
Movement of labor and other persons shall be totally prohibited for reinforcement laid in
position. For access to different parts, suitable mobile platforms shall be provided so that steel
reinforcement in position is not disturbed for ensuring proper cover, mortar blocks of suitable
size shall be cast and tied to the reinforcement. Timber, kapachi or metal pieces shall not be
used for this purpose.

3.5 Transporting and laying :

Signature of Contractor 118


3.5.1 The method of transporting and placing concrete shall be as approved. Concrete shall be
so transported and placed that no contamination, segregation or loss of its constituent material
takes place.
All formwork shall be cleaned and made free from standing water, dust show or ice immediately
before placing of concrete.
No concrete shall be placed in any part of the structure until the approval of the Engineer-in-
charge has been obtained.

3.5.2 Concerting shall proceed continuously over the area between construction joints. Fresh
concrete shall not be placed against concrete which has been in position for more than 30
minutes unless a proper construction joints is formed. Concrete shall be compacted in its final
position within 30 minutes of its discharge from the mixer. Except where otherwise agreed to
by the Engineer-in-charge concrete shall be deposited shall be deposited in horizontal layers to
a compacted depth of not more than 0.45 meter when internal vibrators are used and not
exceeding 0.30 meter in all other cases.

3.5.3 Unless otherwise agreed to by the Engineer-in-charge, concrete shall not be dropped
into place from a height exceeding 2 meters. When trunking or chutes are used they shall be
kept close and used in such a way as to avoid segregation. When concreting has to be resumed
on a surface which has hardened, it shall be roughened, swept clean, thoroughly wetted and
covered with a 13 mm. thick layer of mortar composed of cement and sand in the same ratio as
in the concrete mix itself. This 13 mm. layer of mortar shall be freshly mixed and placed
immediately before placing of new concrete. Where concrete has not fully hardened, all laitance
shall be removed by scrubbing the wet surface with wire or bristle brushes, care being taken to
avoid dislodgement of any particles of coarse aggregate. The surface shall then be thoroughly
wetted all free water removed and then coated with neat cement grout. The first layer of
concrete to be placed on his surface shall not exceed 150 mm. in thickness and shall be well
rammed against old work, particular attention being given to corners and close spots.

3.5.4 All concrete shall be compacted to produce a dense homogeneous mass with the
assistance of vibrators, unless otherwise permitted by the Engineer-in-charge for exceptional
cases, such as concreting under water, where vibrators cannot be used. Sufficient vibrators in
serviceable condition shall be kept at site so that spare equipment is always available in the
event of breakdowns.
Concrete shall be judged to be compacted when the mortar fills the spaces between the coarse
aggregate and begins to cream up to form an even surface. Compaction shall be completed
before the initial setting starts i.e. within 30 minutes of addition of water to dry mixture. During
compaction, it shall be observed that needle vibrators are not applied on reinforcement which is
likely to destroy the bond between concrete and reinforcement.

3.6 Curing : Immediately after compaction, concrete shall be protected from weather,
including rain, running water, shocks, vibration, traffic, rapid temperature changes, frost and
drying out process. It shall be covered with wet sacking, hassain or other similar absorbent
material approved soon after the initial set and shall be kept continuously wet for a period of
not less than 14 days from the date of placement. Masonary work over foundation concrete
may be started after 48 hours of its laying but curing of concrete shall be continued for a
minimum period of 14 days.

3.7 Sampling and Testing of concrete :

Signature of Contractor 119


3.7.1 Samples from fresh concrete shall be taken as per I. S. 1199-1959 and cubes shall be
made, cured and tested at 7 days or 28 days as per requirements in accordance with I. S. 516-
1959. A random sampling procedure shall be adopted to ensure that each concrete batch shall
have a reasonable chance of being tested i.e. the sampling should be spread over the entire
period of concreting and cover all mixing units. The minimum frequency of sampling of concrete
of each grade shall be in accordance with following :

Quantity of concrete No. of samples Quantity of concrete No. of samples


in the work in the works
1-5 Cmt. 1 16-30 Cmt. 3
6-15 Cmt. 2 31-50 4

51 and above + one additional for each additional 50 M. or part thereof.


NOTE : At least one sample shall be taken from each shift. Ten test specimens shall be made
from each sample, five for testing at 7 days and the remaining five at 28 days. The samples of
concrete shall be taken on each day of the concreting as per above frequency. The number of
specimens may be suitably increased as deemed necessary by the Engineer-in-charge when
procedure of tests given above revels a poor quality of concrete and in other special cases.

3.7.2 The average strength of the group of cubes case for each day shall not be less than the
specified cube strength of 150 kg/Cm2 at 28 days. 20% of the cubes cast for each day may
have value less than the specified strength provided the lowest value is not less than 85% of
the specified strength. If the concrete made in accordance with the proportions given for a
particular grade, does not yield the specified strength, such concrete shall be classified as
belonging to the appropriate lower grade. Concrete made in accordance with the proportions
given for a particular grade shall not however, be placed in a higher grade on the ground that
the test strength are higher than the minimum specified.

3.8 Stripping :

3.8.1 The Engineer-in-charge shall be informed in advanced by the contractor of his intention
to strike the form work. While fixing the time for removal of form work due consideration shall
be given to local conditions, character of the structure the weather and other condition that
influence the setting of concrete and of the materials used in the mix in normal circumstances
(generally where temperatures are above 20ºC) and where ordinary concrete is used forms
may be struck after expiry of periods specified in item No. 9.1 (A) for respective item of form
work.

3.8.2 All formwork shall be removed without causing any shock or vibration as would damage
the concrete. Before the soffit and struts are removed the concrete surface shall be exposed
where necessary in order to ascertain that the concrete has sufficiently hardened. Centering
shall be gradually and uniformly lowered in such manner as to permit the concrete to take
stresses due to its own weight uniformly and gradually. Where internal metal ties are permitted
they or their removable parts shall be extracted without causing any damage to the concrete
and remaining holes filled with mortar. No permanently embedded metal part shall have less
than 25 mm. cover to the finished concrete surface. Where it is intended to re-use the
formwork, it shall be cleaned and made good to the satisfaction of the Engineer-in-charge. After
removable of form work and shuttering the Executive Engineer shall inspect the work and
satisfy by random checks that concrete produced is of good quality.

Signature of Contractor 120


3.8.3 Immediately after the removal of forms all exposed bolts etc., passing through the
cement concrete member and use for shuttering or any other purpose shall be cut inside the
cement concrete members to a depth of at least 25 mm. below the surface of the concrete and
the resulting holes be filled by cement mortar. All fine caused by form joints, all cavities
produced by the removal of forms ties and all other holes and depressions honeycomb spots
broken edges or corners and other defects shall be thoroughly cleaned, saturated with water
and carefully pointed and rendered true with mortar of cement and fine aggregate mixed in the
proportion used in the grade of concrete that is being finished and of as dry consistency as is
possible to use. Considerable pressure shall be applied in filling and pointing to ensure through
filling in all voids. Surfaces which are pointed shall be kept moist for a period of 24 hours.
If rock pockets honeycombs in the opinion of the Engineer-in-charge are of such an extent or
character as to effect the strength of the structure materially or to endanger the life of the steel
reinforcement he may declare the concrete defective and require the removal and replacement
of the portions of the structure affected.

4.0 Mode of measurement and payment :

4.1 The consolidated cubical contents of concrete work as specified in item shall be
measured the concrete laid in excess of section shown on drawings or as directed shall not be
measured. No deduction shall be made for
(a) Ends of dis-similar materials such as joints, beams, posts, girders, rafters, purling
trusses, corbels and steps etc. up to 500 Sq. Cm. in section.

(b) opening upto 0.1 Sq. m.

4.2 The rate includes cost of all materials, labor, tools and plant required for mixing, placing
in position, vibrating and compacting, finishing as directed curing and all other incidental
expenses for producing concrete of specified strength. The rate excludes the cost of form work.

4.3 The rate shall be for a unit of one cubic meter.

TMT FE - 415 bar reinforcement for R.C.C. work including bending binding and
placing in position complete up to floor two level.

1.0 Materials : 1.1 Cold twisted steel bars (high yield strength steel deformed bars) shall
conform to M-19 mild steel binding wires shall conform to M-21. The TMT Steel bars shall be
used instead of Mild & High yield deformed bars.

2.0 Workmanship :
2.1 The work shall consist of furnishing and placing reinforcement to the shape and
dimensions shown as on the drawings or as directed.

2.2 Steel shall be clean and free from rust and loose mill scale at the time of fixing in
position and subsequent concreting.

2.3 Reinforcing steel shall conform accurately to the dimensions given in the bar bending
schedules shown on relevant drawings. Bars shall be bent cold to specified shape and
dimensions or as directed using a proper bar bender, operated by hand or power to attain
proper radius of bends. Bars shall not be bent or straightened in a manner that will injure the
material. Bars bent during transport or handling shall be straightened before being used on the
Signature of Contractor 121
work. They shall not be heated to facilitate bending. Unless otherwise specified a „U‟ type hook
at the end of each bar shall invariably be provided to main reinforcement. The radius of the
bend shall not be less than twice the diameter of the round bar and the length of straight part
of the bar beyond the end of the curve shall be at least four times the diameter of the round
bar. In case of bars which are not round and in case of deformed bars, the diameter shall be
taken as the diameter of circle having an equivalent effective area. The hooks shall be suitably
encased to prevent any splitting of the concrete.

2.4 All the reinforcement bars shall be accurately placed in exact position shown on the
drawings and shall be securely held in position during placing of concrete by annealed binding
wire not less than 1 mm. in size and by using stay blocks or metal chair spacers, metal hangers,
supporting wires or other approved devices at sufficiently close intervals. Bars shall not be
allowed to sag between supports nor displaced during concreting or any other operations of the
work. All devices used for positioning shall be of non-corrodible material. Wooden and metal
supports shall no extend to the surface of concrete, except where shown on drawings. Placing
bars on layers of freshly laid concrete as the work progress for adjusting bar spacing shall not
allowed. Pieces of broken stone or brick and wooden blocks shall not be used. Layers of bars
shall be separated by spacebars, precast mortar blocks or other approved devices.
Reinforcement after being placed in position shall be maintained in a clean condition until
completely embedded in concrete. Special care shall be exercised to prevent any displacement
of reinforcement in concrete already placed. To prevent reinforcement from corrosion, concrete
cover shall be provided as indicated on drawings. All the bars producing from concrete and to
which other bars are to be spliced and which are likely to be exposed for a period exceeding 10
days shall be protected by a thick coast of neat cement grout.

2.5 Bars crossing each other where required shall be secured by binding wires (annealed) of
size not less than 1 mm. in such manner that they do not slip over each other at the time of
fixing and concreting.

2.6 As far as possible bars of full length shall be used. In case this is not possible,
overlapping of bars shall be done as directed. When practicable, overlapping bars shall not
touch each other but be kept apart by 25 mm. or 1.25 times the maximum size of the coarse
aggregate whichever is greater by concrete between them. Where not feasible overlapping bars
shall be bound with annealed wires not less than 1 mm. thick twisted tight. The overlaps shall
be staggered for different bears and located at points along the span where neither movement
is maximum.

2.7 Whenever indicated on the drawings or desired by the Engineer-in-charge bars shall be
jointed by couplings which shall have a cross section sufficient to transit the full stresses of
bars. The ends of the bars that are joined by coupling shall be upset for sufficient length so that
the effective cross section at the base of threads is not less than normal cross-section of the
bar. Threads shall be standard threads. Steel for coupling shall conform to I. S. 226. When
permitted or specified on the drawings joints of reinforcement bars shall be butt-welded so as
to transmit their full stresses. Welded joints shall preferably be located at points when steel will
not be subject to more than 75 per cent of the maximum permissible stresses and welds so
staggered that at any one section not more than 20 percent of the rods are welded. Only
electric are welding using a process which excludes air from the molten metal and conforms to
any or all other special provisions for the work shall be accepted. Suitable means shall be
provided for holding bars securely in position during welding. It shall be ensured that no voids
are left in welding and when welding is done in two or three stages previous surface shall be

Signature of Contractor 122


cleaned properly. Ends of the bars shall be cleaned of all loose scale, rust, grease, paint and
other foreign matter before welding. Only competent welders shall be employed on the work.
The M. S. electrodes used for welding shall conform to I. S. 814. Welded pieces of
reinforcement shall be tested. Specimen shall be taken from the actual site and their number
and frequency of test shall be as directed.

3.0 Mode of measurement and payment :


3.1 For the purpose of calculating consumption, wastage shall not be permitted beyond 5
percent. Excess consumption over 5% will be charged at penal rate.

3.2 Reinforcement shall be measured in length including overlaps, separately for different
diameters as actually used in the work. Where welding or coupling is resorted to in place of lap
joints such joints shall be measured for payment as equivalent length of overlap as per design
requirement. From the length so measured the weight if reinforcement shall be calculated in
tones on the same basis of as per M-18 even though steel is supplied to the contractor by the
department on actual weight. Length shall include hooks at the ends. Wastage and annealed
steel wire for binding shall not be measured and the cost of these items shall be deemed to be
included in the rate for reinforcement.

3.3 The rate for reinforcement includes cost of steel binding wires its carting from
Department a store to work site, cutting, bending, placing, binding and fixing in position as
shown on the drawings and as directed. It shall also include all devices for keeping
reinforcement in approved position cost of joining as per approved method and all wastage and
spacer bars.

For all Item

1.0. Materials

1.1. Water shall conform to M-1. Cement shall conform to M-3. Sand shall conform to M-6.
Grit shall conform to M-8 Course aggregate shall conform M-12.

2.0. General

2.1. The relevant specification of item No. 5.4.1. ordinary concrete of Building
specification book shall be followed except that the concrete mix shall be designed from
preliminary tests. The proportioning of cement and aggregates shall be done by weight and
necessary precautions shall be taken in the production to ensure that the required work cube
strength is attained and maintained. The controlled concrete shall be in grades of M-100, M-
150, M-200, M-250, M-300, M-350 & M-400 with prefix controlled added to it. The letter M
refers to mix and the numbers specify 28 days works cube compressive strength of 150 mm.
cubes of the mix expressed in Kg./Crnt.

2.2. The proportion of cement, sand and coarse aggregate shall be determined of
weight. The weight batch machine shall be used for maintaining proper control over the
proportion of aggregates as per mix design. The strength requirements of different grades of
concrete shall be as under:

Signature of Contractor 123


Grade Compressive strength of 15 cms. cubes in Kg./Cmt. At
Work test Min.
Concrete 28 days, conducted in accordance with I.S. 516-1959.
Preliminary test Min.

M-1 50 200 150


M-200 260 200
M-250 320 250
M-300 380 300
M-350 440 350
M-400 500 400

In all cases, the 28 days compressive strength specified in above be the crite ria for
acceptance or rejection of the concrete.
Where the strength of a concrete mix as indicated by tests, lies in between the strength of
any two grades specified in the above table, such concrete shall be classified in for purpose
as concrete belonging to the lower of the grades between which its strength lies.

3.0. Workmanship
3.1. The proportions for ingredients chosen shall be such that concrete has adequate
workability for conditions prevailing on the work question and can be property compacted with
means available except where ft can be shown to the satisfaction of the Engineer-in-charge,
that supply of properly graded aggregate of uniform quality can be maintained till the
completion of work, grading of aggregate shall be controlled by obtaining the coarse
aggregates in different sizes and bending them in the right proportions as required.
Aggregates of different sizes shall be stocked in separate stock piles. The required
quantity of material shall be stock piled several hours, preferably a day before use. The
grading of coarse and fine aggregate shall be checked as frequently as possible, the
frequency for a given job being determined by Engineer-in-charge to ensure that the suppliers
are maintaining the uniform grading as approved for samples used in the preliminary tests..

3.2. In proportioning concrete, the quantity of both cement and aggregate shall be
determined by weight. Where the weight of cement is determined by accepting the maker's
weight per bag, a reasonable number of bags shall be weighted separately to check the net
weight. Where cement is weighted form bulk stocks at site and not by bags, it shall be
weighed separately from the aggregate. Water, shall either be measured by volume in
calibrated tanks or weighed. All measuring equipment shall be maintained in clean, and
serviceable condition. Their accuracy shall be periodically checked.

3.3. It is most important to keep the specified water cement ratio constant and at its
correct value. To this end, moisture content in both fine and coarse aggregates shall be
determined by the Engineer-in-charge according to the weather conditions. The amount of
mixing water shall then be adjusted to compensate for variations in the moisture content.
For the determination of moisture content in the aggregates. I.S. 2386 (Part-Ill) shall be
referred to. Suitable adjustments shah also be made in the weights of aggregates due to
variation in their moisture content.
The minimum quantity of cement used in cement concrete M-25 shall be 360 Kg per
Cum. The maximum quantity of cement shall not be more than 450 kg /Cum.
Signature of Contractor 124
+

Providing formwork of ordinary timber planking so as to give a rough finish including centering ,
shuttering , strutting and propping etc. height of propping and centering below supporting floor
to ceiling not exceeding 4m and removal of the same for cast in situ reinforced concrete and
plain concrete work

1.0. Materials

1.1. The shuttering to be provided shall be of ordinary timber plank and shall conform to M-
26.

1.2. The dimensions of scantlings and battens shall conform to the design. The strength of
the wood shall not be less than that assumed in the design.

2.0. Workmanship

2.1. The form work shall conform to the shape lines and dimensions as shown on the plans
and be constructed as to remain sufficiently rigid during the placing and compacting of the
concrete. Adequate arrangements shall be made by the contractor toe safe-guard against any
settlement of the form-work during the course of concreting and after concreting. The form
work of shuttering, centering, scaffolding, bracing etc. shall be as per design.

2.2. Clearing and Treatment of forms:

2.2.1. All rubbish, particularly chipping shaving and saw dust shall be removed from
the interior of the form before the concrete work is placed and the-form in contact
with concrete shall be cleaned and thoroughly wetted or treated. The surface shall be
then coated with soap solution applied before concreting is done. Soap solution for
the purpose shaft prepared by dissolving yellow soap in water to get
consistency of paint. Alternatively a coat of raw linseed oil shall be applied after
thoroughly cleaning the surface. Care shall be taken that the coating does not get on
construction joint surface and reinforced bars.

2.3. Stripping time:

2.3.1. In normal circumstances and where ordinary cement is used forms may be struck after
expire of following periods.
(a) Sides of walls columns and vertical faces of beams………………………………………24 to 48
hours.
(b) Beam soffits, (props, left under)………………………………………………………………… 7 days.
(c) Removal of props slabs:
(i) Slabs spanning up to 4.5. m…………………………………………………………………………7 days.
(ii) Spanning over 4.5 m ………………………………………………………………………………..14 days.
(d) Removal of props t beams and Arches:
(i) Spanning up to 6 m…………………………………………………………………………………..14 days.
(ii) Spanning over 6 m…………………………………………………………………… …………….21 days.

2.4. Procedure when removing the form work:

Signature of Contractor 125


2.4.1. All form work shall be removed without such shock or vibrations as would damage the
reinforced concrete surface. Before the soffits form work and struts are removed, the soffits
and the concrete surface shall be exposed where necessary in order to ascertain that the
concrete has sufficiently hardened
2.5. Centering:

2.5.1. The centering to be provided shall be got approved. It shall be sufficiently strong to
ensure absolute safety of the form work and concrete work before, during and after pouring
concrete. Watch should be kept to see that behavior or centering and form work is satisfactory
during concreting. Erection should also he such that it would allow removal of forms in proper
sequence without damaging either the concrete or the forms to be removed.

2.5.2. The props of centering shall be provided on firm foundation or base of sufficient
strength to carry the loads without any settlement.
2.5.3. The centering and form work shall, be inspected and approved by the Engineer-in-
charge before concreting.

But this will not relieve the contractor of his responsibility for strength,-adequacy and
safety of form work and centering. If there is a failure of form work or centering, contractor
shall be responsible for the damages to property.

2.6. Scaffolding:

2.6.1. All scaffolding, hoisting arrangements and ladders etc., required for the
facilitating of conceding shall be provided and removed on completion of work by contractor
at his own expense. The scaffolding, hoisting arrangements and ladders etc. shall be strong
enough to with sand all live, dead and impact loads expected to act and shall be subject to
the approval of the Engineer-in-charge. However contractor shall be solely responsible
for the safety of the scaffolding, hoisting arrangement, ladders, work and workman etc.
2.6.2. The scaffolding, hoisting arrangements and ladder shall allow easy approach to the
work spot and afford easy inspection.

2.6.3. The rate is applicable to all condition of working and height up to 4 mts. The rate shall
include the cost of materials and labour for various operations involved such as:

(a) Splayed edges, notching, allowance for overlaps and passing at angles, battens
centering, shuttering propping, bolting, wedging easing, striking and removal.

(b) Filleting to form stop chamfered edges or splayed external angles not exceeding 20
mm: width to beams, columns and the like.

(c) Temporary openings in the forms for pouring concrete, if required removing rubbish etc.

(d) Dressing with oil to prevent adhesion of concrete with shuttering and.

(e) Raking or circular cutting.

2.7. Re-Use:

Signature of Contractor 126


2.7.1. Before re-use, all from shall be inspected by Engineer-in-charge and their suitability
ascertained. The forms shall be scarred, cleaned and joints are gone over, repaired
where required. Inside surface shall be retreated to prevent adhesion of concrete.

Mode of measurement & payment

The consolidated cubical contents of concrete work as specified in item shall be measured.
No deduction shall be made for

(a) Ends of dissimilar materials such as joints, beams, posts, girders, falters, purling trusses,
corbels and steps etc.,up to 500 Sq, Cm. in section.

The rate includes cost of all materials labour, tools and plant required for mixing, placing in
position, vibrating and compacting, finishing, as directed, curing and all other incidental
expenses for producing centre of specified strength.

The controlled concrete R.C.C. work as specified in item shall be measured under this item. The
rate includes cost of concrete & form work. The rate shall be for a unit of one cubic meter.

Brick work using FLYASH bricks having crushing strength not less than 70
kg./sq.cm. in
foundation and plinth in cement mortar 1: 6 (1 cement : 6 fine sand)
Plinth Masonry
(B) Conventional

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials

Water shall conform to M-1. Cement shall conform to M-3. Sand shall conform to M-6. Brick
shall conform to M-15. Cement mortar shall conform to M-11.

2.0. Workmanship

2.1. Proportion:

2.1.1. The proportion of the cement mortar shall be 1:6 (1 cement: 6 fine sand) by volume.

2.2. Wetting of bricks:

2.2.1. The bricks required for masonry shall be thoroughly wetted with clean water for about
two hours before use or as directed. The cessation of bubbles, when the bricks are wetted
with water is as indication of through wetting of bricks.

2.3. Laying:

Signature of Contractor 127


2.3.1. Bricks shall be laid in English bond unless directed otherwise. Half or cut bricks
shall not be used except when necessary to complete to bond; closures in such case shall be
cut to required size and used near the ends of walls.

2.3.2. A layer of mortar shall be spread on full width for suitable length of the lower course.
Each brick shall first be property bedded and set home by gently tapping with handle of
trowel or wooden mallet. Its inside face shall be flushed with mortar before the next brick is
laid and pressed against it. On completion of course, the vertical joints shall be fully filled from
the top with mortar.

2.3.3. The walls shall be taken up truly in plumb. All courses shall be laid truly horizontal and
all vertical joint shall be truly vertical. Vertical joints in alternate course shall generally be
directly one over the other. The thickness of brickcourse shall be kept uniform.

2.3.4. The brick shall be laid with frog up wards. A set of tools comprising of wooden straight
edges, man son's spirit level, square half meter rub, and pins, string and plumb shall be kept on
the site of work for frequent checking during the progress of work.

2.3.5. Both the faces of walls of thickness greater than 23 cms. shall be kept in proper place.
All the connected brick work shall be kept not more than one meter over the rest of the work.
Where this is not possible, the work shall be raked back according to bond (and not left
toothed) at an angle not steeper than 45 degrees.

2.3.6. All futures, pipes, outlets of water, hold fasts of doors and windows etc. which are
required to be built in wall shall be embedded in cement mortar

2.4. Joints:

2.4.1. Bricks shall be so laid that all joints are quite flush with mortar. Thickness of joints shall
not exposed 12 mm.

The face joints shall be raked out as directed by raking tools daily during the progress of work,
when the mortar is still green so as to provide key for plaster or pointing to done.

2.4.2. The face of brick shall be cleaned the very day on which the work is laid and all mortar
dropping removed.

2.5. Curing:

2.5.1. Green work shall be protected from rain suitably. Masonry work shall be kept moist
on all the faces for a period of seven days. The top of masonry work shall be kept well wetted
at the close of the day.

2.6. Preparation of foundation bed:

2.6.1. If the foundation is to be laid directly on the excavated bed, the shall be leveled, cleared
of all loose materials, cleaned and wetted before stating masonry, If masonry is to be laid on
concrete footing, the top of concrete shall be cleaned and moistened. The contractor shall
obtain the engineer's approval for the foundation bed before foundation masonry is started.

Signature of Contractor 128


When pucca flooring is to be provided flush with the top to plinth, the inside plinth offset shall
be kept lower than the outside plinth top by the thickness of the flooring.

3.0. Mode measurements & payment

3.1. The measurements of this item shall be taken for the brick masonry fully completed in
foundation up to plinth.The limiting dimensions not exceeding those shown on the plinths or as
directed shall be final. Battered tapered and curved portions shall be measured net.

3.2. No deduction shall be made from the quantity of brick work, for any extra payment
made for embedding in masonry or making holes in respect of following items:

(1) Ends of joists, beams, posts, girders, purlins, trusses, corbel, steps etc. where cross
sectional area does not exceed 500 Sq.Cm.

(2) Openings not exceeding 1000 Sq.Cm.

(3) Wall plates and bed plates, bearing of slabs, chajjas and the like whose thickness does
not exceed 10 Cms. and the bearing does not extend to the full thickness of wall.

(4) Drainage holes, and recesses for cement concrete blocks to embed hold fasts for doors,
windows etc.

(5) Iron fixtures, pipes up to 300 mm. dia hold fasts, and doors and windows built into
masonry and pipes etc. for concealed wiring.
(6) Forming chases of section not exceeding 350 -Sq. Cm. in masonry.

3.3. Apertures for fire places shall not be deducted nor shall be paid for separately.

3.4. The rate shall be for a unit of one cubic meter.

Flush door shutter


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

FRAME :

1.0. Materials

Wood in frames shall be approved quality teak wood onfirming to M-29.

2.0. Workmanship

2.1. The item covers the requirement of frames for doors, windows, clerestory windows,
their supply and fixing.

2.2. Frames:

Signature of Contractor 129


2.2.1. All members of frames shall be exactly at right angles. The right angle shall be checked
from inside surfaces of the-frames of the respective members.

2.2.2. All members of frames shall be straight without any warp of bow and shall have
smooth surfaces well planed on the three sides exposed at right angles to each other. The
surfaces touching the wall may not be planed unless it is required in order to straighten up the
member or to obtain the overall sizes within the tolerances as specified.

2.2.3. Frame shall have dovetail joins. When clerestory windows in included, it shall be
provided by having full length one piece post for door or windows and clerestory window
extending the frame on top at the head to the required extent. Horns shall not be provided
in the head of the frame. When no sills are provided, the vertical posts of the frame in the
ground floor shall be embedded in the sill masonry for 10 cm. on upper floors, the vertical posts
shall be fixed in the floor or masonry by forming notches 10 mm. deep. Slight adjustment of
spacing as necessary shall be done to have the hold fasts in the joints of masonry; course. The
frame shall be erected in position and held plumb with strong support form north sides and
built in masonry as it is being built. The transom shall be through tenoned into the mortises of
the jamb pot to the full width of the jamb post and the thickness of the tenon shall be not less
than
15 mm.

2.3. Tolerance:
Unless specially mentioned otherwise tolerance of + 1.5. mm shall be allowed for each wrought
face.

2.4. The tenons shall be closely fitting into the mortises and suitably pinned with wood
dowels not less than 10 mm. dia. meter. The depth of rebates for housing the shutter shall be
as shown in the detailed drawing or as directed.

2.5. The concrete surface of tenon and mortise shall be treated before putting
together with an adhesive of approved make.

2.6. Minimum number of three hold-fasts shall be fixed on each side of door and
windows frames, one at the center point and the other two at 30 mm. from the top and
bottom of the frames. In case of windows and ventilators frames. The size c. each hold-fast
shall be 300 x 25 x 6 mm. and of mild-steel with split end. The hold fasts shall be fixed with
screws to frames.

2.7. Mild steel hold fasts shall be protected with a coating of coal asphalt tar. The surface
of frame abutting the masonry or concrete faces shall be properly treated by applying a coat of
approved coating.

SHUTTERS :

Material :

Flush door shall confirm to M-30 on page-16, paints shall confirm to M-44 on page -21 of
Specification book.

Signature of Contractor 130


Flush door shutters shall have a solid core and may be of the decorative or non-decorative
(Paintable type as per IS 2202 (Part I). Nominal thickness of shutters may be 25, 30, 35 or
40mm. Thickness and type of shutters shall be as specified.

Width and height of the shutters shall be as shown in drawings or as indicated by the Engineer-
in-Charge. All four edges of the shutters shall be square. The shutter shall be free from twist or
warp in its plane. The moisture content in timbers used in the manufacture of flush door
shutters shall be not more than 12 per cent when tested according to IS 1708.

Core :

The core of the flush door shutters shall be a block board having wooden strips held in a frame
constructed of stiles and rails. Each stile and rail shall be a single piece without any joint. The
width of the stiles and rails including lipping, where provided shall not be less than 45 mm and
not more than 75 mm. the width of each wooden strip shall not exceed 30 mm. stiles, rails and
wooden strips forming the core of a shutter shall be of equal and uniform thickness. Wooden
strips shall be parallel to the stiles.

End joints of the pieces of wooden strips of small lengths shall be staggered. In a shutter, stiles
and rails shall be of one species of timber. Wooden strips shall also be of one species only but it
may or may not be of the same species as that of the stiles and rails. Any species of timber
may be used for core of flush door. However, any non-coniferous (Hard wood) timber shall be
used for stiles, rails and lipping.

Face Panel :

The face panel shall be formed by gluing, by the hot-press process on both faces of the core,
either plywood or cross-bands and face veneers. The thickness of the cross bands as such or in
the plywood shall be between 1.0 mm and 3.0 mm. The thickness of the face veneers as such
or in the plywood shall be between 0.5 mm and 1.5 mm for commercial veneers and between
0.4 mm and 1.0 mm for decorative veneers, provided that the combined thickness of both is
not less than 2.2 mm. the direction of the veneers adjacent to the core shall be at right angles
to the direction of the wooden strips. Finished faces shall be sanded to smooth even texture.
Commercial face veneers shall conform to marine grade plywood and decorative face veneers
shall conform to type I decorative plywood in IS 1328.

Lipping :

Lipping, where specified, shall be provided internally on all edges of the shutters. Lipping shall
be done with battens of first class hardwood or as specified of depth not less than 25 mm. for
double leaved shutters, depth of the lipping at meeting or stiles shall be not less than 35 mm.
joints shall not be permitted in the lipping.

Rebating :

In the case of double leaves shutters the meeting of stiles shall be rebated by 8 mm to 10 mm.
the rebating shall be either splayed or square type as shown in drawing where lipping is
provided. The depth of lipping at the meeting of stiles shall not be less than 30 mm.

Opening for Glazing :

Signature of Contractor 131


When required by the purchaser opening for glazing shall be provided and unless otherwise
specified the opening for glazing shall be 250 mm in height and 150 mm or 200 mm in width
unless directed otherwise. The bottom of the opening shall be at a height of 1.4 m from the
bottom of the shutter. Opening for glazing shall be lipped internally with wooden batten of
width not less than 25 mm. opening for glazing shall be provided where specified or shown in
the drawing.

Venetian Opening :

Where specified the height of the Venetian opening shall be 350 mm from the bottom of the
shutter. The width of the opening shall be as directed but shall provide for a clear space of 75
mm between the edge of the door and venetian opening but in no case the opening shall
extend beyond the stiles of the shutter. The top edge of the opening shall be lipped internally
with wooden battens of width not less than 25 mm. Venetian opening shall be provided where
specified or shown in the drawing.

Tolerance :

Tolerance on width and height shall be + 3 mm and tolerance on nominal thickness shall be +
1.2 mm. the thickness of the door shutter shall be uniform throughout with a permissible
variation of not more than 0.8 mm when measured at any two points.

Adhesive :

Adhesive used for bonding various components of flush door shutters namely, core, core frame,
lipping, cross – bands, face veneers, plywood etc. and for bonding plywood shall conform to
BWP type, phenol formaldehyde synthetic resin adhesive conforming to IS 848.

Tests :

Samples of flush door shutters shall be subjected to the following tests :

(a) End Immersion Test


(b) Knife Test
(c) Glue Adhesion Test

One end of each sample shutter shall be tested for End Immersion Test. Two specimens of 150
x 150 mm size shall be cut from the two corners at the other end of each sample shutter for
carrying out Glue Adhesion Test. Knife Test shall be done on the remaining portion of each
sample shutter.

Sample Size :

Shutters of decorative and non-decorative type from each manufacturer, irrespective of their
thickness shall be grouped separately and each group shall constitute a lot. The number of
shutters (Sample size) to be selected at random from each lot for testing shall be as specified in
Table. If the total number of shutters of each type in a work (and not the lot) is less than
twenty five testing may be done at the discretion of the Engineer-in-Charge and in such cases

Signature of Contractor 132


extra payment shall be made for the sample shutter provided the sample does not fall in any of
the test specified as above.
For knife test, glue adhesive test, slamming test, the end immersion test, the number of
shutters shall be as per Col. 4 of below Table.

Sample Size and Criteria for Conformity

Lot Size Sample Size Permissible no. of Sub. Sample size


defective
Upto 26 to 50 8 0 1
51 – 100 13 1 2
101 – 150 20 1 2
151 – 300 32 1 3
301 – 500 50 2 4
501 and above 80 2 5

Criteria for Conformity :

All the sample shutters when tested shall satisfy the requirements of the tests laid down in
Appendix F of Chapter 9 of CPWD specifications. The lot shall be declared as conforming to the
requirements when numbers of defective samples does not exceed the permissible number
given in col. 3 of above table. If the number of sample shutters found unsatisfactory for a test
is one, twice the number of samples initially tested shall be selected and tested for the test. All
sample shutters so tested shall satisfy the requirement of the test. If the number of samples
found unsatisfactory for a test is two or more, the entire lot shall be considered unsatisfactory.

Fixing :

For side hung shutters of height upto 1.2m, each leaf shall be hung on two hinges at quarter
points and for shutter of height more than 1.2 m, each leaf shall be hung on three hinges one
at the centre and the other two at 200 mm from the top and bottom of the shutters. Top hung
and bottom hung shutters shall be hung on two hinges fixed at quarter points of top rail or
bottom rail. Centre hung shutter shall be suspended on a suitable pivot in the centre of the
frame. Size and type of hinges and pivots shall be as specified. Flap of hinges shall be neatly
counter sunk into the recesses cut to the exact dimensions of flap. Screws for fixing the hinges
shall be screwed in with screw driver and not hammered in. Unless otherwise specified, shutters
of height more than 1.2 mm shall be hung on butt hinges of size 100 mm and for all other
shutters of lesser height butt hinges of size 75 mm shall be used. For shutter of more than 40
mm thickness butt hinges of size 125 x 90 x 4 mm shall be used. Continuous (piano) hinges
shall be used for fixing cup-board shutters where specified. The shutters shall be provided with
Stainless steel fixtures and fastening and SS handle unless otherwise specified including
painting with priming coat of approved quality primer and two coats of oil painting of approved
make & shade etc complete as per drawing.
+
PAINTING

1.0. Materials

1.1. The ready mixed paint, brushing, wood primer pink shall conform to I.S. 3536-1966

Signature of Contractor 133


2.0. Workmanship

2.1. Preparation of Surfaces :

2.2.1. All wood work shall be dry and free from any foreign matter incidental to building
operations. Nails shall be punched well below the surface to provide a film key for stopping.
Moldings shall be carefully smoothened with abrasive paper and projecting fibers shall be
removed. Flat portions shall be smoothened off with abrasive paper used across the grain prior
to painting prior to painting and with the grain prior to staining or if the wood is to be left in its
natural colour, wood work which is to be stained may be smoothened by scraping instead of by
glass papering if so required.

2.2.2. Any knots, resinous, streaks or bluefish sap wood that are not large enough to justify
cutting out shall be treated with two coats of pure shellac knotting applied thinly and extended
about 25 mm. beyond the actual area requiring treatment.

2.2. Application of primer :

2.2.1. After the preparation of the surface, the priming coat shall be applied immediately.
The brushing operations are to be adjusted to the spreading capacity advised by the
manufacturer of the particular primer. The paint shall be applied evenly and smoothly by
means of crossing and laying off. The crossing and laying off consists of covering the area
over with paint, brushing alternately in opposite directions, two or three times and then
finally brushing lightly in a direction at right angles to the same. In this process, no brush
marks shall be left after the laying off is finished. The full process of crossing and laying off
wall constitute one coat.

2.2.2. During painting, every time, after the priming coat has been worked out of the
brush bristles or after the brush has been unloaded, the bristles of the brush shall be
opened up by striking the brush against portion of the unpainted surface with the end of
the bristles, held at right angles to the surface, so that bristles thereafter will collect the
correct amount of paint when dipped again in to a paint container The prima/y coat shall be
allowed to dry completely before painting is started.

2.2.3. No hair marks from the brush or clogging at pain puddles in the corner of panels
angles of moulding etc.shall be left on the work

2.2.4. The container when not in use shall be kept close and free from air so that paint does
not thickness and also shall be kept guarded from dust.

+
1.0. Materials

1.1. Synthetic enamel paint shall conform to I.S. 1932-1964.

2.0. Workmanship

2.1. General : The materials required for work of painting work shall be obtained
directly from approved manufactures or approved dealer and brought to the site in maker's
drums; kegs. etc. with seal unbroken.

Signature of Contractor 134


2.1.2. All materials not in actual use shall be kept properly protected, lids of containers shall
be kept closed and surface of paint in open or partially open containers covered with a thin
layer of turpentine to prevent formation of skin. The materials which have become state or flat
due to improper and long storage shall not be used. The paint shall be stirred thoroughly in its
container before pouring into small containers. While applying also, the paint shall be
continuously stirred in smaller container. No left over paint shall be put back into stock tins.
When not in use the containers shall be kept properly closed.

2.1.3. If for any reasons, things is necessary, the brand of thinner recommended by the
manufacturer shall be used.

2.1.4. The surface to be painted shall be thoroughly cleaned and dusted. All rust, dirt
and grease shall be thoroughly removed before painting is started. No painting on exterior or
other exposed part o the work shall be carried out in wet, damp or otherwise unfavorable
weather and all the surfaces shall be thoroughly dry before painting work is started.

2.2. Application of paint:

2.2.1. Brushing operations are to be adjusted to the spreading capacity advised by the
manufacture of particular paint. The paint shall be applied evenly and smoothly by means of
crossing and laying off. The crossing and laying off consists of covering the area over with paint,
brushing the surface hard for the first time over and then brushing alternately in opposite
directions two or three times and then finally brushing lightly in a direction at right angles to
the same. In this process, no brush marks shall be left after the -laying off is finished. The full
process of crossing and laying off will constitute one coat.

2.2.2. Each coat shall be allowed to dry completely and lightly rubbed with very fine grade
of sand-paper and loose particles brushed off before next coat is applied. Each coat shall
vary slightly in shade and shall be got approved from Engineer-in-charge before next coat is
started.

2.2.3. Each coat the last shall be lightly rubbed down with sand paper of fine pumice stone
and cleaned of dust before the next coat is applied. No hair marks from the brush of clogging
of paint puddles in the corners of panels, angles of moldings etc. shall be left on the work.

2.2.4. Approved best quality brushes shall be used.

The synthetic enamel paint shall be used for painting on new wood/wood based surfaces. In
painting doors and windows, the putty, round the glass panes also be painted but care shall be
taken to see that no paint, stain etc. are left on the glass. Top of shutters and surfaces in similar
hidden locations shall not be left out in painting.

Measurements :

Length and width of the shutters shall be measured to the nearest cm in closed position
covering the rebates of the frames but excluding the gap between the shutter and the frame.
Overlap of two shutters shall not be measured.

Signature of Contractor 135


All work shall be measured net as fixed and area calculated in square metres to nearest two
places of decimal. No deduction shall be made for providing venetian opening and opening for
glazing.

Rate :

The rate includes the cost of material and labour involved in all the operations described above.
Extra rate shall be payable for providing rebates in double leaved shutters. Glazing when
provided shall be measured and paid for separately as, for paneling of each type or for glazed
panel length and width of opening for panels inserts or glazed panels shall be measured correct
to a cm before fixing the beading and the area shall be calculated to the nearest 0.01 sq.m. The
portions of panel inserts or glazed panel inside the grooves or rebates shall not be measured for
payment.

Item No.-40: (For Schedule B)

Providing and fixing 35 mm thick Decorative type flush door shutters, solid core
construction with frame of first class hard-wood with cross band and face veneer or
ply-wood face panels,1.5 mm thick laminate on both sides including Stainless steel
fixtures and fastening and SS handle including primer coat of approved quality and
two coats of oil painting etc complete.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

The relevant specification as described in item-39 shall be followed. The work shall be
carried out for 35 mm thick Decorative type flush door shutters only.

The rate shall be for a unit of one sq. meter.

Item No.-41: (For Schedule B)

Providing and fixing anodised aluminium work for WINDOWS AND VENTILATORS
with Anodised aluminium ( anodised transparent or dyed to required shade
according to IS: 1868, Minimum anodic coating of grade AC 15 ) heavy duty
extruded built up standard tubular sections/appropriate Z sections and other
sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl
plugs and screws or with fixing clips, or with expansion hold fasts including
necessary filling up of gaps at junctions, at top, bottom and sides with required
PVC/neoprene felt or sealent of wecker 789 or Dow corning 789 grade so as to
make all joints waterproof etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically wherever required including cleat angle,
auminium snap beading for glazing / panelling, stainless steel screws as per
architectural drawings and the directions of Engineer-in-charge and incl. providing
and fixing glazing in aluminium WINDOW AND VENTILATOR shutters etc. with
EDPM gasket etc. complete as per the architectural drawings and the directions of
engineer-in-charge with 6.0 mm thick plain float glass panel of approved shade and

Signature of Contractor 136


approved make and fixed to the frames and frames fixed to the walls. The framed
ends shall have required brushings for proper sealing.

The Window shall be three Track with sliding shutters and the frame section of size
101.6 x 44.45 x 2.01 of weighing 1.605 Kg./Rmt., window frame with bottom
member of size 61.85 x 31.75 x 1.5 weighing 0.909 Kg./Rmt. top and sides member
of size 61.85 x 31.75 x 1.5 weighting 0.784 Kg./Rmt. With shutter frame of top
member of size 40 x 18 x 1.55 weighing 0.547 kg / Rmt and bottom member of size
52 x 18 x 1.55 weighing 0.651 kg / Rmt,interlock member of size 40 x 18 x 1.45
weighing .607 kg / Rmt ,and handle member of size 40 x 18 x 1.55 weighing 0.547
kg / Rmt of extruded alluminium colour anodized section and frames with
necessary aluminium handles and locking arrangement etc. complete including
necessary cutting and making good etc. complete.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

General :

Aluminium Sections :

Aluminium sections used for fixed / openable windows, ventilators, partitions, frame work &
doors etc., shall be suitable for use to meet architectural designs to relevant works and shall be
subject to approval of the Engineer-in-Charge for technical, structural, functional and visual
considerations. The aluminium extruded sections shall conform to IS 733 and IS 1285 for
chemical composition and mechanical properties. The stainless steel screws shall be of grade
AISI 304.

The permissible dimensional tolerance of the extruded sections shall be as per IS 6477 and shall
be such as not to impair the proper and smooth functioning / operation and appearance of door
and windows.
Aluminium glazed doors, windows etc. shall be of sizes, sections and details as shown in the
drawings. The details shown in the drawings may be varied slightly to suit the standards
adopted by the manufacturers of the aluminium work, with the approval of Engineer-in-Charge.
Before proceeding with any fabrication work, the contractor shall prepare and submit, complete
fabrication and installation drawings for each type of glazing doors, windows, ventilators and
partition etc. for the approval of the Engineer-in-Charge. If the sections are varied, the
contractor shall obtain prior approval of Engineer-in-Charge and nothing extra shall be paid on
this account.

Anodising:

Standard aluminium extrusion sections are manufactured in various sizes and shapes in wide
range of solid and hollow profiles with different functional shapes for architectural, structural
glazing, curtain walls, doors, window and ventilators and various other purposes. The anodizing
of these products is required to be done before the fabrication work by anodizing/electro
coating plants which ensures uniform coating in uniform colour and shades. The extrusions are
anodized up to 30 micron in different colours. The anodized extrusions are tested regularly
under strict quality control adhering to Indian standard.

Signature of Contractor 137


EPDM GASKETS :

The EPDM Gaskets shall be of size and profile as shown in drawings and as called for to render
the glazing, doors, windows, ventilators etc., air and water tight. Samples of gaskets shall be
submitted for approval and the EPDM gasket approved by Engineer-in-Charge shall only be
used. The contractor shall submit documentary proof of using the above material in the work to
the entire satisfaction of Engineer-in-Charge.

The EPDM gasket shall meet the requirements given in Table below :

Sr. Description Standard Follow Specification


No.
1 Tensile strength kg. f/cm2 ASTM-D 412 70 Min.
2 Elongation at break % ASTM-D 412 250 Min.
3 Modulus 100% kg. f/cm2 ASTM-D 412 22 Min.
4 Compression set % at 00 CC 22 ASTM-D 395 50 Max.
Hrs.
5 Ozone resistance ASTM-D 1149 No visible cracks

SEALANT :

The sealants of approved grade and colour shall only be used. The silicon for perimeter joints
(between aluminium section and RCC/Stone masonry) shall be of make as approved by
Engineer-in-Charge.

Method of Application :

Surface Preparation : Clean all joints and glazing pockets by removing all foreign matter and
contaminants such as grease, oil, dust, water, frost, surface dirt, old sealants or glazing
compounds and protective coatings.
Masking :

Areas adjacent to joint shall be masked to ensure neat sealant lines. Masking tape shall not be
allowed to touch clean surfaces to which the silicone sealant is to adhere. Tooling shall be
completed in one continuous stroke immediately after sealant application and before a skin
forms and masking shall be removed immediately after tooling.

Application :

Install backer rod of appropriate size and apply silicone sealant in a continuous operation using
a positive pressure adequate to properly fill and seal the joint. The silicone sealant shall be
tooled with light pressure to spread the sealant against backing material and the joint. Soap or
water shall not be used as a tooling aid. Remove masking tape as soon as silicone joint is
tooled.

Tolerance : A tolerance of + 3 mm shall be allowed in the width of silicone joints. The depth of
the joints at throat shall not be less than 6 mm.
Signature of Contractor 138
DOOR, WINDOW, VENTILATOR AND PARTITION FRAMES

Frame work :

First of all shop drawings for each type of doors/windows/ventilators etc. shall be prepared by
using suitable sections based on architectural drawings, adequate to meet the
requirement/specification and by taking into consideration varying profiles of aluminium
sections being extruded by approved manufacturers. The shop drawings shall show full size
sections of glazed doors, windows, ventilators etc. The shop drawings shall also show the
details of fittings and joints. Before start of the work, all the shop drawings shall be got
approved from the Engineer-in-Charge.

Actual measurement of openings left at site for different type of door/window etc. shall be
taken. The fabrication of the individual door/widows/ ventilators etc. shall be done as per the
actual sizes of the opening left at site. The frames shall be truly rectangular and flat with
regular shape corners fabricated to true right angles. The frames shall be fabricated out of
section which have been cut to length, mitered and joined mechanically using appropriate
machines. Mitered joints shall be corner shall be corner crimped or fixed with self tapping
stainless steel screws using extruded aluminium cleats of required length and profile. All
aluminium work shall provide for replacing damaged/broken glass panes without having to
remove or damage any member of exterior finishing material.

Fixing of Frames :

The holes in concrete/masonry/wood/any other members for fixing anchor


bolts/fasteners/screws shall be drilled with an appropriate electric drill.
Windows/doors/ventilators etc. shall be placed in correct final position in the opening and fixed
to Sal wood backing using stainless steel screws of star headed, counter sunk and matching
size groove of required size at spacing not more than 250 mm c/c or dash fastener. All joints
shall be sealed with approved silicone sealants.
In the case of composite windows and doors, the different units are to be assembled first. The
assembled composite units shall be checked for line, level and plumb before final fixing is done.
Engineer-in-Charge in his sole discretion may allow the units to be assembled in their final
location if the situation so warrants. Snap beadings and EPDM gasket shall be fixed as per the
detail shown in the shop drawings.

Where aluminium comes into contact with stone masonry, brick work, concrete, plaster or
dissimilar metal, it shall be coated with an approved insulation lacquer, paint or plastic tape to
ensure that electrochemical corrosion is avoided. Insulation material shall be trimmed off to a
clean flush line on completion.

The contractor shall be responsible for the doors, windows etc. being set straight, plumb, level
and for their satisfactory operation after fixing is complete.

DOOR, WINDOWS AND VENTILATOR SHUTTERS:

Material, fabrication and dimensions of aluminium doors, windows and ventilators manufactured
from extruded aluminium alloy sections of standard sizes and designs complete with fittings,
ready for being fixed into the buildings shall be as per IS 1948.

Signature of Contractor 139


Standard Sizes, Tolerances and Designations :

The types and the overall sizes of aluminium doors, windows and ventilators shall be as given
as per drawings. Their sizes shall be derived after allowing 1.25mm clearances on all the four
sides for the purpose of fitting the doors, windows and ventilators into modular openings.

Tolerances :

The sizes for doors, windows and ventilators frames shall not vary by more than + 1.5mm.

Material :

Aluminium alloy extruded sections used in the manufacture of extruded window sections shall
conform to IS 733. Hollows aluminium alloy senctions used shall conform to IS 1285.
Dimensions and weight per metre run of the extruded sections shall be as given as per design /
drawings.

Fabrication :

Frame : Frames shall be square and flat, the corners of the frame being fabricated to a true
right angle. Both the fixed and opening frames shall be constructed of sections which have
been cut to length, metered and welded at the corners. Where hollow sections are used with
welded joints, argon-arc welding or flash butt welding shall be employed gas welding or brazing
not to be done). Subdividing bars of units shall be tenoned and riveted into the frame.

Doors :

The outer fixed frame shall be of section A1-FX8. The shutter frame shall be of either hollow
sections A1-HFX5 and A1-HFX6.

The kick panels if specified shall be of 1.25 mm aluminium alloy sheet conforming to IS
Designation NS3-1/2H of IS 737 specification for Wrought Aluminium and Aluminium Alloys,
Sheet and strip and shall be screwed to the frame and the glazing bar.

Hinges :

Cast of extruded aluminium alloy hinges for door shall be of the same type as in the windows
but of larger size. The hinges shall normally be of the 50 mm projecting type. Non-projecting
type of hinges may also be used.

A suitable lock for the door operable either from inside or outside shall be provided.

Note: From the point of view of security, the lock which is operable from only one side is better
and in the case of such locks, a bolt shall be provided to make them inoperable from the other
side.

In double shutter doors the first closing shutter shall have a concealed aluminium alloy bolt at
top and bottom. It shall be so constructed as not to work loose or drop by its own weight.

Signature of Contractor 140


Single and double shutter doors may be provided with a three-way bolting device. Where this is
provided in the case of double shutter door, concealed aluminium bolts may not be provided.

Composite Units :

The doors shall be coupled to windows or side-lights by extruded aluminium sections made
from aluminium alloy conform to IS Designation HE9-WP of IS 733.

Weather Bar :

Where a coupling member is fitted over an external opening shutter, the coupling member
should incorporate an integrally extruded weather bar.

Position of Bolts, Fixing Screws and Lugs :

Outer frames shall be provided with fixing holes centrally in the web of the sections in the
position. Moreover, any steel lugs coming in contact with aluminium should be either galvanized
or given one coat of bituminous plaint.

The fixing screws and lugs shall be as given in table :

Sr. Place of Fixing Size of Screw or Lug


No.

(i) To wooden frames rebated on the 30mm x No. 10 galvanized wood-screws.


outside
(ii) To plugs in concrete, stone or brick -Do -
work rebated on the outside

(iii) To plugs in concrete, stone or brick 45mm x No. galvanized wood-screws


work not rebated on the outside (that
is plain or square jambs)

(iv) Direct to brick work or masonry (that is Slotted steel adjustable lugs (natural
plain or square jambs) finish) not less than 100 x 16 x 3mm
countersunk galvanized machine screws
and nuts 19.0 x 6.3 mm.

(v) To steel work Standard clip and 8 mm galvanized bolts


with hexagonal nuts.

Finish :

Aluminium doors, windows and ventilators may be supplied in either matt, scratch-brush or
polished finish. They may, additionally, also be anodized, if specified. If colour anodizing is to
be done then only approved light-fast shades should be used.

A thick layer of clear transparent lacquer based on methacrylates or cellulose butyrate, shall be
applied on aluminium doors, windows and ventilators by the supplier to protect the surface

Signature of Contractor 141


from wet cement during installation. This lacquer coating shall be removed after installation is
completed.

Glazing :

Glazing shall be provided on the outside of the frames.

If required, glazing clips may be provided as extra fittings. Four / Six glazing clips may be
provided per glass pane as specified. In case of doors, windows and ventilators without
horizontal glazing bars the glazing clips shall be spaced according to the slots in the vertical
members, otherwise the spacing shall be 30 cm.
Note : Glazing clips are not usually provided for normal size glass panes. Where large size glass
panes are required to be used or where the door or the window is located in heavily exposed
situation, holes for glazing clips have to be drilled prior to fabrication and cannot be done at any
later stage. Use of glazing clips, where necessary, shall be specified while placing the order.

Stainless Steel Friction Stay :


The stainless tell friction stays of make approved by the Engineer-in-Charge shall be used. The
SS friction stays shall be of grade AISI-304 and of sizes specified in nomenclature of item.

Lockable Handles :

The lockable handles shall be of make approved by the Engineer-in-Charge and of required
colour to match the colour of powder coated / anodized aluminium window sections.

Hydraulic Floor Spring :

The hydraulic floor spring shall be heavy duty double action floor spring of make approved by
the Engineer-in-Charge suitable for door leaf of weight minimum 100 kg. The top cover plate
shall be of stainless steel, flushing with floor finish level. The contractor shall cut the floor
properly with stone cutting machine to exact size & shape. The spindle of suitable length to
accommodate the floor finish shall be used. The contractor shall give the guarantee duly
supported by the company for proper functioning of floor spring at least for 10 years.

Tubular Handle :

The tubular handle bar shall be aluminium polyester powder coated minimum 50 micron to
required colour or anodized AC 15 or as specified. Outer dia of tube thickness 3.0 mm and
centre to centre length 2115 mm + 5 mm.

Measurements :

Length and width of the shutters incl. all aluminium section frames incl. snap beadings shall be
measured to the nearest cm in closed position Overlap of two shutters shall not be measured.

All work shall be measured net as fixed and area calculated in square metres to nearest two
places of decimal. No deduction shall be made for providing venetian opening and opening for
glazing.

Rate :

Signature of Contractor 142


The rate includes the cost of material and labour involved in all the operations described above.
Glazing shall be measured and shall be included in the area. The area shall be calculated to the
nearest 0.01 sq.m.

The rate shall include the cost of all the materials, labour involved in all the operations as
described in nomenclature of item and particular specification.

LOUVERS :

Aluminium extruded sections (anodized or powder coated) are used for providing Louvers in
aluminium door, window & partition for ventilation.

Fabrication :

First of all shop drawings for each type of doors/windows/ventilators etc. shall be prepared by
using suitable sections based on architectural drawings, adequate to meet the
requirement/specification and by taking into consideration varying profiles of aluminium
sections being extruded by approved manufacturers. The shop drawings shall show full size
sections of glazed doors, windows, ventilators etc. The shop drawings shall also show the
details of fittings and joints. Before start of the work, all the shop drawings shall be got
approved from the Engineer-in-Charge.

Actual measurement of openings left at site for different type of door/window etc. shall be
taken. The fabrication of the individual door/widows/ ventilators etc. shall be done as per the
actual sizes of the opening left at site. The frames shall be truly rectangular and flat with
regular shape corners fabricated to true right angles. The frames shall be fabricated out of
section which have been cut to length, mitered and joined mechanically using appropriate
machines. Mitered joints shall be corner shall be corner crimped or fixed with self tapping
stainless steel screws using extruded aluminium cleats of required length and profile. All
aluminium work shall provide for replacing damaged/broken glass panes without having to
remove or damage any member of exterior finishing material.

GLAZING :

Glass in doors, windows, glazing and ventilators shall be 5 mm thick or as specified float glass,
clearer ,tinted or reflective as mentioned in the item, and shall be approved quality stains,
scratches, bubbles and flaws of any kind and shall be properly cut to fit framed and mullions. All
windows and ventilators shall be glazed from outside with snap fit anodized aluminium heading
and EDPM/ gasket lining complete. The buildings, shall be snap fit and shall be fitted without
use of screws. No screws other than those on some of the hardware shall be visible.

Measurements :

Length and width of the shutters incl. all aluminium section frames incl. snap beadings shall be
measured to the nearest cm in closed position Overlap of two shutters shall not be measured.

All work shall be measured net as fixed and area calculated in square metres to nearest two
places of decimal. No deduction shall be made for providing venetian opening and opening for
glazing.

Signature of Contractor 143


Rate :

The rate includes the cost of material and labour involved in all the operations described above.
Glazing shall be measured and shall be included in the area. The area shall be calculated to the
nearest 0.01 sq.m.

The rate shall include the cost of all the materials, labour involved in all the operations as
described

M.S. Grill

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials

The structural steel shall conform to M-22

2.0. Workmanship

2.1. The M.S. Grill shall be prepared as per the drawing or as directed for fixing to wooden
frames or marble Frame of windows / balcony etc.

2.2. The grill shall be fabricated to the designs and patterns shown in the drawings and
the weight shall be as directed, and the joints shall be reverted or welded as shown in the
plan or as directed. The grill so formed shall be fixed into the frames of the windows etc.
before they are erected in position. The outside strip frame of the grill shall be housed to its
full thickness into the recess cut into the frame of the windows etc. The grill shall be fixed to
the frame with number of bolts and nuts or screws viz. bolt nut/screw per 30 cm. of the
length of outer strip subject to minimum of 2 Nos. on each side of the frame or as indicated in
the drawing or as directed.

2.3. The bolts and nuts or screws shall be counter sunk and shall be fixed with the top of
their heads flush with the face of the frame strips.

PAINTING :

1.0. Materials

1.1. The ready mixed primer, brushing red shall conform to I.S. 102-1962.

1.2. The thinner (linseed oil) shall conform to I.S. 75-1973. If for any reason, thinning is
necessary m case of
ready mix paint the brand of thinner recommended by manufacture shall be used.

2.0. Workmanship

Signature of Contractor 144


2.1. Preparation of surfaces : The surfaces painting shall be cleaned of all rust, scale,
dirt and other foreign matter sticking to it with wire brushes, steel wool, scrapers, sand paper
etc. This surface shall then be wiped finally with mineral turpentine which shall also remove
grease and perspiration of hand marks. The surface shall then be allowed to dry.

2.2. Application of primer :

2.2.1. After the preparation of the surface, the priming coat shall be applied immediately.
The brushing operations are to be adjusted to the spreading capacity advised by the
manufacturer of the particular primer. The paint shall be applied evenly and smoothly by
means of crossing and laying off. The crossing and laying off consists of covering the area
over with paint, brushing alternately in opposite directions, two or three times and then
finally brushing lightly in a direction at right angles to the same. In this process, no brush
marks shall be left after the laying off is finished. The full process of crossing and laying off
wall constitute one coat.

2.2.2. During painting, every time, after the priming coat has been worked out of the
brush bristles or after the brush has been unloaded, the bristles of the brush shall be
opened up by striking the brush against portion of the unpainted surface with the end of
the bristles, held at right angles to the surface, so that bristles thereafter will collect the
correct amount of paint when dipped again in to a paint container The prima/y coat shall be
allowed to dry completely before painting is started.

2.2.3. No hair marks from the brush or clogging at pain puddles in the corner of panels
angles of molding etc. shall be left on the work

2.2.4. Special care shall be taken while painting over bolts, nuts, rivets, overlaps etc.

2.2.5. The container when not in use shall be kept close and free from air so that paint does
not thickness and also shall be kept guarded from dust.

1.0. Materials

Synthetic enamel paint shall conform to I.S. 1932-1964.

2.0. Workmanship

2.1. General : The materials required for work of painting work shall be obtained
directly from approved manufactures or approved dealer and brought to the site in maker's
drums; kegs. etc. with seal unbroken.

2.1.2. All materials not in actual use shall be kept properly protected, lids of containers shall
be kept closed and surface of paint in open or partially open containers covered with a thin
layer of turpentine to prevent formation of skin. The materials which have become state or flat
due to improper and long storage shall not be used. The paint shall be stirred thoroughly in its
container before pouring into small containers. While applying also, the paint shall
be continuously stirred in smaller container. No left over paint shall be put back into stock tins.
When not in use the containers shall be kept properly closed.
Signature of Contractor 145
2.1.3. If for any reasons, things is necessary, the brand of thinner recommended by the
manufacturer shall be used.

2.1.4. The surface to be painted shall be thoroughly cleaned and dusted. All rust, dirt
and grease shall be thoroughly removed before painting is started. No painting on exterior or
other exposed part o the work shall be carried out in wet, damp or otherwise unfavorable
weather and all the surfaces shall be thoroughly dry before painting work is started.

2.2. Application of paint:

2.2.1. Brushing operations are to be adjusted to the spreading capacity advised by the
manufacture of particular paint. The paint shall be applied evenly and smoothly by means of
crossing and laying off. The crossing and laying
off consists of covering the area over with paint, brushing the surface hard for the first time
over and then brushing alternately in opposite directions two or three times and then finally
brushing lightly in a direction at right angles to the same. In this process, no brush marks shall
be left after the -laying off is finished. The full process of crossing and laying off will constitute
one coat.

2.2.2. Each coat shall be allowed to dry completely and lightly rubbed with very fine grade
of sand-paper and loose particles brushed off before next coat is applied. Each coat shall
vary slightly in shade and shall be got
approved from Engineer-in-charge before next coat is started.

2.2.3. Each coat the last shall be lightly rubbed down with sand paper of fine pumice stone
and cleaned of dust before the next coat is applied. No hair marks from the brush of clogging
of paint puddles in the corners of panels, angles of moldings etc. shall be left on the work.

2.2.4. Special care shall be taken while painting over bolts, nuts, rivets, overlaps etc.
Approved best quality brushes shall be used.

3.0. Mode of measurements & payment

3.1. No payment shall be made for weight of screws, bolts nuts etc. only weight of grill shall
be paid.

3.2. The rate shall be for a unit of one kg.

TEAKWOOD ARCHITERIVES
In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

Material :
Wood in architraves shall confirm to M-29 on page-15, paints shall confirm to M-44.

Workmanship :

Signature of Contractor 146


The teak wood ARCHITREAVES of size 10 mm thick x 40 mm wide shall be made as per
architectural drawing and instruction complete for all heights and all floor, priming coat shall
confirm to

1.0. Materials
1.1. The ready mixed paint, brushing, wood primer pink shall conform to I.S. 3536-1966

2.1. Preparation of Surfaces :


2.2.1. All wood work shall be dry and free from any foreign matter incidental to building
operations. Nails shall be punched well below the surface to provide a film key for stopping.
Mouldings shall be carefully smoothened with abrasive paper and projecting fibers shall be
removed. Flat portions shall be smoothened off with abrasive paper used across the grain prior
to painting prior to painting and with the grain prior to staining or if the wood is to be left in its
natural colour, wood work which is to be stained may be smoothened by scraping instead of by
glass papering if so required.

2.2.2. Any knots, resinous, streaks or bluefish sap wood that are not large enough to justify
cutting out shall be treated with two coats of pure shellac knotting applied thinly and extended
about 25 mm. beyond the actual area requiring treatment.

2.2. Application of primer :

2.2.1. The relevant specifications of item No. 19.12(A) of specification of building work booklet,
shall be followed for application of primer. The ready mixed paint brushing priming for enamel
shall be used instead of ready mixed paint brushing wood primer pink.

+
1.0. Materials

1.1. Synthetic enamel paint shall conform to I.S. 1932-1964.

2.0. Workmanship

2.1. The relevant specifications of 19.7 specification of building work booklet shall be
followed for general and application of paint, except that the enamel paint shall be used for
painting on new wood/wood based surfaces.

2.2. In painting doors and windows, the putty, round the glass panes also be painted but
care shall be taken to see that no paint, stain etc. are left on the glass. Top of shutters and
surfaces in similar hidden locations shall not be left out in painting.

Fixtures & Fastenings :

The rate shall include fixing with iron screws at regular interval of about 150 mm.

Mode of measurement and payment :

The rate includes cost of all materials, tools, plants and labour involved in satisfactory
completion of work including cost of primers & painting etc. The paint shall be synthetic enamel
paint of approved quality & shade.

Signature of Contractor 147


The rate shall be for unit of One Rmt as per actual work done.

The work shall be carried out as per detailed drawings and as directed by Engineer in charge.

S.S. Pipe Railing

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

The Stainless steel pipe railing shall be made using round S.S. pipe of various diameter of
approved quality with S.S. No. 304 consisting 8 % nickel having pipe of 16 gauge including
Horizontal and vertical pipe as per detailed drawing. The Vertical pipe ( posts ) shall be firmly
embedded in flooring with concrete to give a proper and tough support. The pipes should be
inter connected by stainless steel gas welding. All joints having a smooth finish including
required fixtures and fastening of approved quality. The fabrication should be done as per
detailed drawing and as per instructions given by E.I.C. including all material and labour
required etc. complete.

Mode of measurement and payment :

The rate includes cost of all materials, tools, plants and labour involved in satisfactory
completion of work

The rate shall be for unit of One Rmt as per actual work done.

M.S. Fan Clamp

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials
1.1. M.S. Bar shall conform to M-18.

2.0. Workmanship
2.1. The shape and size of fan clamp shall be as directed. The M.S. fan clamp shall be
placed in position as per the drawing on sand bedding of size 150 mm x 150 mm
x 50 mm while casting the R .C.C. slab. The two arms of the ends of the clamp shall be
passed through the space over reinforcement bar from the bottom of the slab. Then the two
arms shall be bent down about 15 mm. by means of crow bar. The clamp shall be made
open after the R.C.C. Slab got strength after 28 days. Th e sand beddind shall be
removed & the clamp shall be held in position and the chase in ceiling shall be filled with
cement concrete of approved grade.The ceiling shall be then finished to match the existing
surface and properly cured.

3.0. Mode of measurements and payment

Signature of Contractor 148


3.1. The rate includes cost of all materials and lobour required for satisfactory completion of
this item as described above.

3.2. The rate shall be for a unit of One number.

Cement plaster

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials
1.1. Water shall conform to M-1. The cement mortar of proportion 1:4 shall conform to M-
13.

2.0. Workmanship

2.1. Scaffolding:

Wooden bullies, bamboos, planks, trestles and other scaffolding shall be sound. These shall
be properly examined before erection and use. Stage scaffolding shall be provided for ceiling
plaster which shall be independent of the walls.

2.2. Preparation of back-ground :

2.2.1. The surface shall be cleaned of all dust, loose mortar droppings, traces of algae,
efflorescence and other foreign matter by water or by brushing. Smooth surface shall be
toughened by wire brushing if it is not hard and by hacking if it is hard. In case of concrete
surface, if a chemical retarded has been applied to the form work, the surface shall be
roughened by wire brushing and all the resulting dust and loose particles cleaned off and
care shall be taken that none of the readers if left on the surface. Trimming of projections
on brick/concrete surfaces where necessary shall be carried out to get an even surface.

2.2.2. Raking of joints in case of masonry where necessary shall be allowed to dry out for
sufficient period before carrying out the plaster work.

2.2.3. The work shall not be soaked but only damped evenly before applying the plaster. If
the surface becomes dry, such area shall be moistened again.

2.2.4. For external plaster, the pestering operation shall be started from top floor and
carried downwards. For internal plaster, the plastering operations may be-started wherever the
building frame and cladding work are ready and the temporary supports of the ceiling resting
on the wall of the floor have been removed. Ceiling plaster shall be completed before starting
plaster to walls.

2:3. Application of plaster :

2.3.1. The plaster about 15 x15 cms. shall be first applied horizontally and vertically at not
more than 2 meters intervals over the entire surface to serve as gauge. The surfaces of
these gauges shall be truly in plane of the finished plastered surface. The mortar shall then

Signature of Contractor 149


be applied in uniform surface slightly more than the specified thickness, then brought to a
true surface by working a wooden straight edge reaching across the gauges with small upward
and sideways movements at a time. Finally, the surface shall be finished off true with a trowel
or wooden float according as a smooth or a smooth or a sandy granular texture is required
Excessive troweling or overworking the float shall be avoided. All corners, arises, angles and
junctions shall be truly vertical or horizontal as the case may be and shall be carefully finished.
Hounding or chamfering, corners, arises junctions etc. shall be carried out with proper
templates to be size required.

2.3.2. Cement plaster shall be used within half an hour after addition of water. And mortar
or plaster which is partially set shall be rejected and removed forthwith from the site.

2.3.3. In suspending the work at the end of the day, the plaster shall be left out clean to the
line both horizontally and vertically, when recommencing the plaster, the edges of the old work
shall be scraped clean and wetted with cement putty before plaster is applied to the adjacent
areas to enable the two to properly join together. Plastering work shall be closed at the end of
the day on the body of the wall and nearer than 15 cm. to any corners or arises.
It shall not be closed on the body of features such as plaster bands and cornices not at
the corners or arises.
Horizontal joints in plaster work shall not also occur on parapet tops and copings as
these invariably lead to leakage. No portion of the surface shall be left out initially to be packed
up later on.

2.3.4. Each coat shall be kept damp continuously till the next coat is applied or for a
minimum period of 7 days. Moistening shall commence as soon as plaster is hardened
sufficiently. Soaking of walls shall be avoided and only as much water as can be readily
absorbed shall be used, excessive evaporation on the sunny or windward side of building in hot
air or dry weather shall be prevented by hanging matting or gunny bags oh the outside of the
plaster and keeping them wet.

3.0. Mode of measurements & payment

3.1. The rate shall include the cost of all materials, labour and scaffolding etc. involved
in the operations described under workmanship.
3.2. All plastering shall be measured in square meters unless otherwise specified. Length
breadth or height shall be measured correct to a centimeter.
3.3. Thickness of the plaster shall be exclusive of t he thickness of the key i.e. grooves or
open joints in brick work, stone work etc. or space between laths. Thickness of plaster shall
be average thickness with minimum 15 mm. at any point on this surface.
3.4. This item includes plastering up to floor two level.
3.5. The measurement of wall plastering shall be taken between the walls or partition
(dimensions before plastering being taken) for length and from the top of floor or skirting to
ceiling for height. Depth of cover of cornices if any shall be deducted.
3.6. Soffits of stairs shall be measured as plastering on ceilings, following soffits shall be
measured separately.
3.7. For jambs, soffits, sills etc. for openings not exceeding 0.5 sq. met each in area for
ends of joints beams,posts, girders, steps etc. not exceeding 0.5 sq. mt each in area and for
openings exceeding 0.5. sq. mt and not exceeding 3.00 sq. mt. in each area deductions and
additions shall be made in the following manners.

Signature of Contractor 150


(a) No deductions shall be made for ends of joints, beams, posts etc. and openings not
exceeding 0.5 sq. mt each and no addition shall be made for reveals, jambs, soffits, sils
etc. of these openings, for finish to plaster around ends of joints, beams posts etc.

(b) Deduction for openings exceeding 0.5 sq. mt but not exceeding 3 sq.mt. each shall be
made as follows and no addition shall be made for ravels, jambs, soffits, sills etc. of these
openings, (i) When both faces of all wall are plastered with same plaster, deduction shall be
made for one face only, (ii) When two faces of wall are plastered with different types of
plasters or if one face is plastered and the other pointed, deductions shall be made from the
plaster or pointing on the side of frame for door, window etc. on which width of reveals is less
than that on the other side but no deductions shall be made on the other side. Where width
of reveals on both faces of all are equal, deductions of 50% of area of opening on each face
shall be made from areas of plaster and / or pointing as the case may be.

3.8. For openings having door frames equal to or projecting beyond the thickness of
wall, full deduction for opening shall be made from each plastered face of the wall.

3.9. In case of openings of area above 3 sq. mt. each, deduction shall be made for
openings but jambs, soffits sand sills shall be measured.

3.10. The rate shall be for a unit of One sq. meter.


Item No.-50: (For Schedule B)

Providing & applying 10 mm thick cement plaster in single coat on fair side of
Ceiling
surface/ Sloping Roof etc. for Ground Floor upto floor two levels finished even and
smooth in C.M. 1:4 (1 cement : 4 Sand ) including necessary curing, scaffolding, in
true
line and level etc. complete as directed by Engineer in Charge.
Ground Floor

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

The relevant item-48 shall be followed except that this work is for ceiling, soffits of stairs
up lo two floor. The 10 mm thick cement plaster shall be applied on ceiling, sloping roof, soffit of
staircase in C.M 1:4 (1 cement : 4 Sand )

Cement Vata ( 10 cm x 10 cm size ) quarter In general the work shall be carried out as
per the standard specifications of P.W.D. / C.P.W.D./ GWSSB relevant drawings and as per the
instructions of Engineer in Charge. Work shall be carried out as per item description.

1.0. Materials
1.1. Water shall conform to M-1 .Cement mortar shall conform to M-11.

2.0. Workmanship
2.1. The work of cement vata of 10 cms x 10 cms. size shall be carried out at junctions
of parapets and terraces as directed. The vata shall he finished in quarter round shape. The
work shall be carried out in the best workman like manner. The inter portion of rain water

Signature of Contractor 151


pipe shall be rounded off properly during constructing the vata. The work shall be cured for 7
days.

3.0. Mode of measurements and payment


3.1. The work shall be measured for finished item in running meter
3.2. The rate shall be for a One running meter.

Wall painting ( Three Coats ) with plastic emulsion paint


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials

Water shall be conform M-1. The plastic emulsion shall conform to I.S.: 5411-1969 (part-l).

2.0. Workmanship

2.1. Scaffolding :

Wherever scaffolding is necessary it shall be erected in such a way that as far as possible on
part of scaffolding shall rest against the surface to be painted. A properly secured strong
and well tied suspended platform (Zoola) may be used for white washing. Where ladders are
used pieces of old gunny bags shall be tied at top and bottom to prevent scratches to the floors
and walls. For plastic paint on ceilings, proper stage scaffolding shall be erected where
necessary.

2.2. Preparation of surface :

2.2.1. The undecorated surface to be plastic painted shall be thoroughly brushed from
dust, dirt, grease, mortar dropping and other foreign matter and sand papered smooth. New
plaster surface shall be allowed to dry for at least 2 months before applications of plastic paint.

2.2.2. All unnecessary nails shall be removed. Pitting in plaster shall be made good with plaster
again with a fine grade sand paper and made smooth. A coat of plastic paint shall be applied
over the patches. The surface shall be allowed to dry thoroughly before the regular coat of
plastic paint is allowed. The surface affected by moulds, moss, fungi, algae lichens,
efflorescence etc. shall be treated in accordance with I.S; 2395 (Part 01) 1966. Before applying
plastic paint, any unevenness shall be made good by applying putty made of plaster of pairs
mixed with water on entire surface including filling up the undulation and then sand papering
the same after it is dry.

2.3. Preparation of Mix :

This shall be done as per manufacture's instructions. The thinning of emulsion is to be done
with water and not with turpentine. The quantity of thinner to be added shall be as per
manufacturer instructions.

2.4. Application :

Signature of Contractor 152


2.4.1. Before pouring into small containers for use, the paint shall be stirred thoroughly in item
container. When applying also, the paint shall be continuously stirred in the smaller container,
so that its consistency is kept uniform.

2.4.2. The paint shall be laid on evenly and smoothly by means of crossing and
laying off the crossing and consist of covering the area over with paint, brushing the surface
hard for the first time over and then, brushing alternately in opposite direction two or three
times and then finally brushing lightly in direction at right angles to the same. In this process,
no brush Marks shall be left after the laying off is finished. No hair marks from the brush or
clogging of paint puddles in the corners of panels, angles of moldings, etc. shall be
left on the work. The full process of crossing and laying off will constitute one coat.

2.4.3. The paint shall be applied with brush or rollers. For undecorated surfaces, the surface
shall be treated with minimum two coats of cement water proofing paint. The
second or subsequent coat shall not be started until the proceeding coat as become
sufficiently hard to resist marking by brushing being used.

2.4.4. The surface on finishing shall present a flat velvety smooth finish. It shall be even and
uniform in shade without patches, brush marks, paint drops etc.
2.5. Precautions :

(a) Old brushes if they are to be used with emulsion paints, shall be completely dried of
turpentine or oil paint by washing in warm soap water. Brushes shall be quickly washed
in water immediately after use and kept immersed in water fusing break periods to prevent
the paint from hardening on the brush.

(b) In the preparation of wall for plastic emulsion painting, no oil base petals shall be sued
in filling cracks, holes etc.

(c) Splashes on floors etc. shall be cleaned out without delay as they will be
difficult to remove after hardening.

(d) Washing or surfaces treated with emulsion paint shall not be done within 3 to 4 weeks
of application

3.0. Mode of measurements and payment

3.1. All the work shall be measured in the decimal system as under:
(a) Dimensions shall be measured to the nearest 0.01 m.
(b) Area in individual item shall be worked out to the nearest 0.01 sq.m.

All the work shall be measured in sq. mt. Deductions for jambs, soffits, sills etc. for openings
not exceeding 0.5 sq.mt. each in area, for ends of joists, posts, beams, girders, steps etc. not
exceeding 0.5 sq mt. each in area and for openings exceeding 0.5 sq. mt. and not exceeding
3.0. sq. mt. each in area, deductions and additions shall be made as under.

3.2. No deductions shall be made for ends of joists, beams, posts, etc. and openings not
exceeding 0.5 sq mt. each. No addition shall be made for reveals, jambs, soffits, sills etc. of
these openings not for finish around ends of joints, beams, posts etc.

Signature of Contractor 153


3.3. No deductions for openings exceeding 0.5 sq.mt. but not exceeding 3 sq. mt.
each shall be made as follows and no addition will be made for reveals, jambs, soffits etc. of
these openings :

(a) When both the faces of walls are provided with finish, deduction shall be made for one
face only.
(b) When each face of wall is provided with different finish, deduction shall be made for that
side of frame for door, windows, etc. on which width of reveals is less than that of the other
side. Where width of reveals on both faces of wall are equal, deduction of .50% of area of
opening on each face shall be made from total area of finish.
(c) When only one face of wall is treated and the other face is not treated, full deduction
shall be made if the
width of reveal on the treated side is less than that on the untreated side, but if the width of
the reveal is equal or more than on the untreated side neither deductions nor additions to be
made for reveals, jambs, soffits, sills etc.

3..4 In case of area of openings exceeding 3 sq. mt. each, deductions shall be made for
openings but jambs, soffits, sills shall be measured.

3.5. No deductions shall be made for attachment such as casing, conducts, pipe, electric
wiring and the like.

3.6. Corrugated surfaces shall be measured flat as fixed and not girth. The quantities so
measured shall be increased by the following percentage and the resultant shall be included
with the general areas:

(a) Corrugated steel sheets……………………………………… 14%


(b) Corrugated A.C. sheets………………………………………. 20%
(c) Semi corrugated A.C. Sheets……………………………….. 10%
(d) Nainital pattern roof (Plain sheeting sheets)………………..10%
(e) Naintial pattern roof (with corrugated sheets)………………25%

3.7. Cornices and other wall features, when they are not picked out in a different
finish/colour shall be girthed and included in the general area.

3.8. The rate shall include the cost of ail materials, labour, scaffolding, protective measures
etc. involved in all the operations described above.

3.9. The rate shall be for a unit of One sq. meter.

Granite slab 18mm thick in flooring treads


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials

Water shall conform to M-1. Lime mortar shall conform to M-10. Cement mortar shall conform
to M-1). Granite stone slab 18 mm. thick shall conform to M-52 or as specified in the schedule.

Signature of Contractor 154


2.1. Dressing of slabs :
Every stone shall be cut to required size and fine chisel dressed to give a smooth and even
surface on all sides to full depth. A straight edge laid along the sides of the stone shall be fully
in contact with it Chisel dressing shall also be done on top surface to remove any waviness. The
sides and top surface of Granite slabs shall be machine rubbed or table rubbed with coarse
sand before using. All angles and edges or slabs shall be true, square and free from chipping.

2.2 The thickness of stone shall be 18 to20 mm or as specified in the schedule. The
allowable tolerance shall be 2 mm. allowable. The 'tolerance shall + 5 mm. in length and
breadth.

2.3. Bedding:

Bedding of granite slabs shall either be time mortar 1:1.5 (1 lime putty : 1.5 coarse sand) or
cement mortar 1:6 (1cement : 6 coarse sand) of average thickness 20 mm. thick as given in
description of item. Minimum thickness at any place shall not be less than 10 mm.

2.4. Laying

The surface of sub-grade shall be cleared, wetted and mopped. Mortar of specified mix and
thickness shall then be spread on an area sufficient to receive one granite slab. The slab shall
be washed clean before laying. It tie laid on top pressed and tapped gently to bring it in level
with other slabs. It shall then be lifted and a side. The top surface of the mortar shall then be
corrected by adding fresh mortar at hollows, or depressions. The mortar shall then be
allowed to harden it over this surface cement slurry or honey like consistency at 4.4 Kg. of
cement per sq. meter. The edges of slabs already paved shall be buttered with gray
cement. The slab shall then be gently placed in position and tapped with wooden mallet till
it is properly bedded in level with and close to the adjoining slab. The joints shall be as fine as
possible. Surplus cement on the surface of the slab shall be removed. The slab fixed in the floor
adjoining the walls shall enter not less than 10 mm. under the plaster skirting or dado. The
junction between the walls and floors shall be finished neatly. The finished surface shall be true
to level and slopes as directed.

2.5. Curing : The floor shall be cured for a minimum period of seven days.

2.6. Polishing and finishing:

Unevenness at the meeting edges of slab shall be removed by fine chiseling. Finishing etc.
shall be done as per relevant specifications of item No. 14.21 (A) of specification booklet of
R & B or terrazzo tiles flooring except that cement slurry with/or without pigments shall
not be applied on the surface before each polishing.

3.0. Mode of measurements and payment

3.1. Granite stone flooring shall be measured in sq. meter. The length and breadth shall be
measured between-the finished face of skirting or dado or wall plaster No deduction shall be
made nor extra shall be paid for opening in the floor or area up to 0.05 sq. mt. Nothing extra
shall be paid for laying stone at different levels in the same room. Treads and steps of stairs
paved with granite stone slabs shall be also be

Signature of Contractor 155


measured under flooring.
3.2. The rate shall be for a unit of one sq. meter.

Item No.-67: (For Schedule B)


Granite slab 18mm thick in skirting, riser of steps and landing laid
In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

The item shall be carried out as per specifications as described above but the work shall be
carried out in skirting, riser of steps laid on a bed of 10mm thick base of CM 1:4 ( 1 Cement : 4
Coarse sand ) finishes with flush pointing in white or colour cement.

The rate shall be for a unit of one sq. meter.

Material and Workmanship :

The Granite stone / Marble stone / Kotah stone shall be provided and laid as per item no. 14.44
of specification booklet of R & B. This particular item includes rounding edges of Granite stone /
Marble stone /Kotah stone in desired and approved shape. The rounding shall be carried out
with proper cutting and grinding tools and the rounded surface shall be finished smooth and
polished. The edges shall also be maintained straight.

Mode of Measurement & payment :


The rate shall be for RMT of the edges rounded along the edge of the stone.

600 mm x 600 mm Anti skid / Glossy Tiles


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

Vitrified Anti skid / Glossy polished porcelain floor tiles shall be of 1st quality. The vitrified tiles
are classified under group B1a of the International Standard for ceramic tiles ISO: 13006. Tiles
shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than
0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. Vitrified
polished porcelain floor tiles shall be provided of sizes, colour, shades, texture and designs as
indicated and if size not indicated it shall be 24" x 24" ( 600mm x 600mm / 605 x 605 mm).
The thickness shall be as specified by the manufacturer but not less than 10mm.

Heavy duty vitrified unpolished porcelain floor tiles for exterior use shall be of 1st quality Heavy
duty vitrified tiles shall be acid and alkali resistant, weather proof, anti skid and abrasion
resistant as per International Standard for ceramic tiles ISO: 13006 and EN 176 requirements.
Theses tiles shall comply with the following requirements:-

(a) Water absorption<2%


(b) Flexural Strength>35 N/Sqmm
(c) Moh‟s Hardness>6
(d) Abrasion resistance<204mm.

Signature of Contractor 156


Heavy duty vitrified tiles shall be of sizes, colour, texture and designs as indicated but size if not
indicated it shall be of 300mm x 300mm. the thickness shall be as specified by the
manufacturer,

Bedding:

The screed bed for laying Vitrified Porcelain Tiles shall be of cement and sand mortar 1:6.
Bedding over which the tiles shall be laid shall not be less than 10mm at any place.

Laying :

Base concrete or RCC slab shall be cleaned and wetted. The bedding shall then be laid evenly
over the surface, tamped and corrected to desired levels and allowed to harden enough to offer
a rigid cushion to tiles. Before laying the tiles, tiles shall be washed and then applied fine
cement slurry on the back of the tile to ensure full and proper bedding. Tiles shall then be
placed on bedding, each tile being gently tapped with rubber hammer in its position till it is
properly bedded and in level and line with adjoining tiles. Use of spacers is recommended for
uniformity in joints and better finish. Remove the residual cement or jointing material
immediately by a wet sponge. After 24 hours when the tiles are properly set and cured, fill the
joint gaps with joint filler as per recommendation of manufacturer. The joint gap shall be filled
by spreading joint filler paste in th spaces between the tiles with the help of rubber trowel.
Clean the tiles surface immediately with the help of wet sponge.

Vitrified Porcelain Tiles can be laid in flooring over Base concrete or RCC slab directly by using
suitable chemical adhesive as per manufacturers instructions if so indicated.

Mode of Measurement : The work shall be measured in sqm.

KOTAH STONE SHELVES


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

Material :

Water shall conform to M-1 Cement mortar shall conform to M-11, Polished Kotah stone shall
conform to M-49 of approved brand & quality. The Kotah or Polished Kotah Stones shall be
of approved quality, free from defects and dressed in the fashion stated under specification.
The thickness shall be as stated in the schedule with 3 mm tolerance. The stones shall of
uniform green in colour with straight edges. The sides of machine cut and machine polished
stones shall have perfect right angles and surface on earth. The stone shall be polished on both
sides.

Workmanship :

When a single piece of polished kotah stone slab is to be fixed as in divider wall etc. the slab
shall be fixed as described below :
The stone is fixed making grooves of required size in wall. The mortar pads of 1:3 C.M. of
uniform width shall be struck on to the wall at close intervals and the kotah stone slabs shall be

Signature of Contractor 157


pressed on to them firmly. The remaining cavities if any, shall then be filled with thin grout of
cement mortar of the same proportion. The sound coming on gently tapping of the slab will
indicate if there are hollows. When the hollow cannot be filled with grout and the finished slab
continues to give a hollow cannot be filled with grout and the finished slab continues to give a
hollow sound on tapping, the slab shall be removed and reset.
The stone shall be fixed truly in plumb and in perfect line as shown on the plans. The surface
shall be protected from sun and rain and cured for ten days and shall be finally polished.

Mode of Measurement and Payment :

The rate includes cost of all materials, tools, plants and labour involved in satisfactory
completion of work etc.

The rate shall be for unit of One Sq.mt as per actual work done.

The work shall be carried out as per detailed drawings and as directed by Engineer in charge.
Measurements shall be in sq.mt. of the actual area.

Decorative Parking Tiles :

The Mosaic decorative tiles of approved make, type and size shall be provides

Preparation of Surface and Laying :

Base concrete or the RCC slab on which the tiles are to be laid shall be cleaned, wetted and
mopped. The bedding for the tile shall be with cement mortar 1:6 (1 cement : 6 coarse sand) or
as specified. The average thickness of the bedding shall be 20 mm or as specified while the
thickness under any portion of the tiles shall not be less than 10 mm.

Mortar shall be spread, tamped and corrected to proper levels and allowed to harden
sufficiently to offer a fairly rigid cushion for the tiles to be set and to enable the mason to place
wooden plank across and squat on it.

Over this mortar bedding neat grey cement slurry of honey like consistency shall be spread at
the rate of 3.3 kg of cement per square metre over an area upto one square metre. Tiles shall
be soaked in water washed clean and shall be fixed in this grout one after another, each tile
gently being tapped with a wooden mallet till it is properly bedded and in level with the
adjoining tiles. The joints shall be kept as thin as possible and in straight lines or to suit the
required pattern.

The surface of the flooring during laying shall be frequently checked with a straight edge about
2 m long, so as to obtain a true surface with the required slope. In bath, toilet W.C., kitchen
and balcony/verandah flooring, suitable tile drop or as shown in drawing will be given in
addition to required slope to avoid spread of water. Further tile drop will also be provided near
floor trap.

Signature of Contractor 158


Where full size tiles cannot be fixed these shall be fixed these shall be cut (sawn) to the
required size, and their edge rubbed smooth to ensure straight and true joints.

Tiles which are fixed in the floor adjoining the wall shall enter not less than 10 mm under the
plaster, skirting or dado.

After tiles have been laid surplus cement slurry shall be cleaned off.

Pointing and Finishing :

The joints shall be cleaned off the grey cement slurry with wire/coir brush or trowel to a depth
of 2 mm to 3 mm and all dust and loose mortar removed. Joints shall then be flush pointed with
white cement added with pigment if required to match the colour of tiles. Where spacer lug tiles
are provided, the half the depth of joint shall be filled with polyshulphide or as specified on top
with under filling with cement grout without the lugs remaining exposed. The floor shall then be
kept wet for 7 days. After curing, the surface shall be washed and finished clean. The finished
floor shall not sound hollow when tapped with a wooden mallet.

Measurement :

Length and breadth shall be measured correct to a cm before laying skirting, dado or wall
plaster and the area calculated in square metre correct to two places of decimal. Where coves
are used at the junctions, the length and breadth shall be measured between the lower edges
of the coves.

No deduction shall be made nor extra paid for voids not exceeding 0.20 square metre.
Deductions for ends of dissimilar materials or other articles embedded shall not be made for
area not exceeding 0.10 square metre.

Areas, where glazed tiles or different types of decorative tiles are used will be measured
separately.

Operations as described above shall be followed except the tiles shall conform to Table 12 of IS
15622 (Tiles with water absorption E < 0.08 percent Group B I a) and the joint thickness in
flooring shall not be more than 1mm.

Rate :

The rate for flooring shall include the cost of all materials and labour involved in all the
operations described above. Nothing extra shall be paid for the use of cut (sawn) tiles in the
work.

China mosaic type water proofing treatment on terrace including


Material :

The cement shall confirm to M-3 (3.1 ), water shall confirm to M-1 (1.1 to 1.5), sand shall
confirm to m-6 (6.1 to 6.3 ), water proofing compound shall confirm to manufacturer‟s
specification, brick bats shall confirm to M-14 (14.1 to 14.2 ) and cement mortar shall confirm

Signature of Contractor 159


to M-11 (11.1 to 11.3.2 ). White glazed tiles used for items shall be broken to proper size and
shape. Material shall be got approved by Engineer in charge.

Preparing the Surface :

It would be advantageous to roughen the surface by scrapping the surface when the slab is
being cast, however the surface need not be hacked. In case the slab is already cast and
surface fairly finished, the same shall be cleaned neatly of all mortar droppings, loose materials
etc.

Blending Cement/Water with water proofing compound :

I. Whenever the water proofing compound is to be used, it is advantageous to blend the


same with cement if the water proofing compound is in powder from and if the same is
in liquid form the required quantity of water blended with water proofing compound
alone should be used for preparing slurry / mortar.

II. The water proofing compound to be used shall conform to IS : 2645 and be of reputed
brand with a clear ISI marked on the container which should be in the form of sealed
tins or closed packets.

III. The correct quantity of water proofing compound to be used per 50 kg grey cement
shall be as prescribed by the manufacturer on the tins/ packets literature. However, not
more than 3% of water proofing compound shall be used per 50 kg of grey cement.

IV. Blended cement with water proofing compound or water mixed with liquid water
proofing compound shall be used to prepare slurry/mortar.

Preparing of Slurry :

I. The quantity of water required to prepare the slurry with 2.75 kg of cement to painted
over an area of 1 sqm shall be calculated exactly. Consider this quantity of water as x
liter per sqm.

II. Depending upon the area of surface that has to be covered, the required quantity of
slurry should be prepared using 2.75 kg blended cement + x litres of water per sqm
area to be covered, taking particular care to see that only that much quantity of slurry
shall be prepared which can be used within ½ and hour of preparation.

Application of Slurry under Base coat :

I. The slurry prepared as explained above shall be applied over the dempened surface with
brushes very carefully, including the joints between the floor slab and the parapet wall,
holes on the surfaces and joints of pipes in masonry / concrete.

II. The application of the slurry should continue up to a height of 300 mm over the parapet
wall and also to the groove. The slurry should also be applied up to a height of 150 mm
over pipe projection etc.

Laying Base coat 20 mm thick :


Signature of Contractor 160
Immediately after the application of slurry and when the application is still green, 20 mm thick
cement plaster as base coat with cement mortar 1:4 (1 blended cement : 4 coarse sand) shall
be evenly applied over the concrete surface taking particular care to see that all corners and
joints are properly packed and the application of the base coat shall be continued up to a height
of 300 mm over the parapet wall.

Preparing Brick-Bat Concrete Mix :

I. Brick bat of size 25mm to 100mm out of cover burnt bricks shall be used for the purpose
of brick bat coba.

II. Depending upon the area of concrete surface to be covered the calculated quantity of
brick bats to cover the area shall be heaped for mixing. Cement mortar 1:5 (1 blended
cement : 5 coarse sand) shall be prepared separately of half the quantity of brick bats,
collected by volume.

III. The bricks bats shall be properly dampened for six hours before the cement mortar is
added. The materials shall be thoroughly mixed by adding some water if needed and
the homogenous mix thus prepared should only be used. Under no circumstances dry
brick bats should be mixed with the mortar.

Laying Brick bat coba :

I. When the base coat takes initial set or preferably on the subsequent day the brick bat
coba after mixing as specified above shall be laid to required slope / gradient. To ensure
fixing up of proper level/gradient correct level points should be fixed with brick bat coba
mix only and the brick bat coba shall be laid to the top of level points. The surface of
brick bat coba shall be finished neatly to proper slope.

II. The haunches / gola at the junction of parapet wall and the roof shall be formed only
with brick bat coba.

III. In case the brick bat coba is laid on the base coat immediately on initial set there will be
no necessary of applying cement slurry over the base coat before laying the brick-bat
coba. However, if the brick bat coba is to be laid on the subsequent day, cement slurry
prepared as described above shall be applied over the top surface of the base coat, then
only the brick bat coba shall be laid.

Application of Slurry Over Brick-bat Coba :

Immediately on laying brick-bat coba i.e. when the initial set takes place, or at least on the
subsequent day cement slurry prepared as described above it shall be applied on the surface of
brick-bat coba. The application of slurry shall be the same as described which should cover the
haunches / gola, and the remaining small portion of parapet wall and also inside the groove.

Laying Finishing Layer (Protective Coat) of China Mosaic :

I. Immediately on applying the cement slurry over the surface of the brick bat coba and
when the slurry applied is still green, a 20 mm thick layer of cement plaster, without

Signature of Contractor 161


leaving any joints shall be applied with cement mortar 1:4 (1 blended grey cement : 4
coarse sand) over the entire surface including the haunches/gola and the small portion
on the parapet wall. The groove in the parapet wall over the haunches shall also be
filled neatly packing the mortar firmly in the groove.

II. Combination of white and coloured broken pieces of ceramic / glazed tiles of even
thickness shall be laid on the layer of cement mortar immediately. The broken tile
pieces shall be laid and pressed uniformly and entire surface shall be pressed by wooden
template, so that the pieces gets pressed in uniform layer and do note protrude above
the surface. The surface shall then be filled and finished with white cement slurry. The
China mosaic layer shall be done in pattern and design given in the drawings. The
treatment shall also be continued along inner side of parapet up to the height of 30cm
in the shape of round vata. Care shall be taken to see that the surface remain smooth
and it is neatly cleaned and finished of all slurries, dirt after laying.

Curing and Testing the Treatment :

The entire surface thus treated shall be flooded with water by making kiaries with weak cement
mortar, water shall be made to remain on the roof slab for a minimum period of two weeks
during which it can be observed if there are any leakage or not.

Brick bat coba shall be provided as specified, however recommended average thickness is
120mm and minimum at Khurra as 65 mm.

Mode of measurement and payment :

 The rate incl. all the material and labour involved in the satisfactory completion of work.
 The item with all respect, the payment shall be made on square meter basis and
measurement shall be taken as per the clear inside length and breadth from parapet
wall and average over finishing floor as breadth.

 A guarantee bond of ten years guarantee requisite stamp paper shall be given by the
contractor to the department. Any defect will be observed later on, shall be rectified by
the contractor at his own risk and cost. Contractor shall be bound to carry out all such
rectification work without claiming any extra. The rate shall be unit for a one square
meter.

Composite water proofing treatment to floor and walls of water tank, w.c.bath
area.

Materials : Water shall conform to M-1, Cement shall conform to M-3, Sand shall conform to
M-6, Cement mortar shall conform to M – 11, Waterproofing compound/ admixture shall
conform to approved make & specifications.

CRYSTALINE WATER PROOFING SYSTEM :

MATERIAL:

Signature of Contractor 162


Water proofing chemicals shall be cementitious based of dry crystaline power capable to
creating crystals to seal the pores, intecises and micro cracks in the concrete. The crystaline
powder shall be of krypton or equivalent make and shall match the product specification of
krypton T2 powder of krypton or equivalent make. This system when applied should become
integral part of concrete and should not get affected by surface wear and abrasion. This will be
applied on wet saturated new or old concrete surfaces. It should be non toxic and suitable for
application in drinking water tanks. It will be able to withstand high hydrostatic pressure, stop
moisture coming up through concrete to debond any overlay system. It should eliminate the
need for surface applied membranes. It should not contain any sterates, sodium or silicate and
should not be of hydrophobic type. It should be able to grow crystals year after year and should
seal micro cracks (not live / moving cracks) that may occur from subsequent damage to
structure.

PROCEDURE :

Surface preparation and application :

1. Concrete surfaces will be cleaned and made free of contaminants and laitance.
2. Concrete must be sound.
3. Concrete will be cleaned to have an open pore surface to allow penetration of Krystol. This
may require mechanical preparation such as grinding, waterblasting, sandblasting or
hacking.
4. Surfaces to be treated will be pro-soaked with clean water to a saturated surface dry (SSD)
condition. Do not leave any standing water.
5. Mix Krystol T2 to a slurry consistency (5 parts power to 2 part clean water) or as
recommended by manufacturer. Mix only enough material that can be placed in 15 minutes
to 20 minutes.
6. Apply slurry to the concrete surface with a brush in circular, scrubbing motion so as to
achieve maximum adhesion and penetration. Apply the slurry to the entire concrete slab.
7. Apply Krystol T2 with a spread rate of 1 kg/m2 or as recommended by manufacturer.
8. Protect the area from rapidly drying out due to heat, damage by rain, excessive wind and
freezing temperatures for 48 hours.
9. Testing with pounding to be done after 7 days.

For construction joints treatment a U – shaped groove will be made of 10mm wide and 15-
20mm deep. This will be filled up with Krystol T2 putty consistency 5:1 (5 parts of T2 to 1 part
of water) and Krystol Baricote in 3.5:1 (3.5 part of Baricote to 1 part of water) or as
recommended by manufacturer.

After testing with ponding after 7 days, a layer of plaster with waterproofing compound/
admixture about 25 mm thick in the floor / depression and about 18 mm on the sidewalls /
depression upto the floor level shall be provided over the surface treated with crystalline
powder. The waterproof plaster about 18 mm thick to be continued on the walls above the floor
level for full height with surface suitable to receive further finishing treatment all complete as
per companies specifications and instructions and as directed for all heights and floors. The
round vata shall be included in this in sq.mt. and shall be taken upto top of round on wall.

Mode of Measurement and payment :

Signature of Contractor 163


The rates includes all materials, labour, tools and plants in satisfactory completion of work as
specified above.

The round vata shall be included in this in sq.m and shall be taken upto top of round on wall.

The rates shall be for unit of one Sq.mt. for actual work done.

Item No.-80: (For Schedule B)

Item No.-81: (For Schedule B)

Providing, laying & jointing to level and slope rigid ISI make of approved make
P.V.C. pipes of working pressure 6 Kg/sq.cm for Horizontal drainage line below
ground level including necessary fittings such as bends, tees, rubber packing ring
etc. testing of pipeline, jointing with adhesive solvent cement including cost of
excavation,lowering and laying pipes, refilling the trenches, jointing materials and
all other necessary fixtures fitted, air and water tight testing of the line etc.
complete as directed.
160mm dia PVC pipes

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials

1.1. The low density polythene pipe of specified diameter with 6 Kg/Sq. Cm, working
pressure shall conform to I.S. 3076-1968. The specials and fittings required shall be of best
quality.

2.0. Workmanship

2.1. The P.V.C. pipes of specified diameter shall be fixed as directed. Due to thermal
expansion of rigid ' P.V.D. pipes, due allowance shall be made particularly in over ground pipe
lines for any change in length of pipe line which may occur during installation or when pipe line
which may occur during installation or when pipe line is in service.

2.2. Above ground installation of rigid P.V.C. pipe should be under taken after preparations
are observed for their protection against direct sun rays and mechanical damage.

2.3. The rigid P.V.C. pipe lines should not be kept exposed above ground when it passes
through public places, railway lines, road side and foot paths.

2.4. P.V.C. pipes shall be supported at the following intervals :


-20 mm. dia 500 mm. -25 mm. dia 750.mm. -32 mm. dia.900 mm.

2.5. Closer support spacing shall be provided if recommended by the manufacture.

Signature of Contractor 164


2.6. The guide lines indicated by the manufacturer regarding handling, transportation,
storing, laying and jointing pf pipes shall be kept in view during execution.

2.7. Jointing the pipes :

2.7.1. The pipes and sockets shall be accurately cut. The ends of the pipes and fittings should
be absolutely free from dirt and dust. The outside surface of the pipes and the inside of the
fittings shall then be roughened with emery paper, and then solvent cement joint. Since
solvent cement is aggressive to P V.C. care must be taken to avoid applying excessive
cement to the inside of pipe sockets as any surplus cement cannot be wiped of after
jointing. Empty solvent cement tins, brushes, rags, or paper impregnated with cement should
not be buried in the trenches. They should be gathered not left scattered about, as-they can
prove to be a hazard to animals, which may chew them.

2.7.2. If any manufacturer recommends its own methods of jointing the same shall be
adopted after necessary approval from the Engineer-in-charge.

2.8 Laying pipes in Trenches :

2.8.1. The pipes shall be laid over uniform relatively soft fine trained soil found to be free of
presence of hard object such as large flints, rocky projections, large tree roots etc. The width of
the trenches shall be minimum width required for working.

2.8.2. The pipes laid underground shall not be less than one meter from the ground
level. The pipe shall be positioned in the trenches so as to avoid any induced stressed
due to deflection. Any deviation required shall be obtained by using proper type of rubber
ring joints.

2.9 Mode of measurements & payment

2.9.1 The relevant specifications of item 23.2. (A) of specification for Building work booklet
shall be followed except that the P.V.C. pipes of specified dia. shall be paid under this item.

2.9.2 The unit rate shall be for a unit of One running meter.

Colored Wash down water closet European type WC pan


1.0. Materials
Wash down water closet (European type W.C. Pan) shall conform to M-60. Cement mortar shah
conform to M-11.

2.0. Workmanship
2.1. The closet shall be fixed to the floor by means of 75 mm. long 6.5 mm. diameter
counter sunk bolts and nuts embedded in the floor concrete using rubber or before washers
so as not to allow any lateral displacement The joint between the trap of W.C. and soil pipe
shall ho made with C M. 1:1 (1 cement : 1 fine sand).

3.0. Mode of measurements and payment


3.1. The rate shall includes the cost of all materials and labour involved in all the
operations described under workmanship.

Signature of Contractor 165


3.2. The rate includes cost of all labour for fixing pans and sent and cover, inlet,
connections etc. complete including testing the same. The payment of seat and cover shall be
made separately.

3.3. The rate shall be for a unit of One number.

P.V.C. low level flushing cistern


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

The flushing cisterns shall be automatic of manually operated high level or low level as
specified, for water closets and urinals. A high level cistern is intended to operate with minimum
height of 125 cm and a low level cistern with a maximum height of 30 cm between the top of
the pan and under side of the cistern.

Cisterns shall be of following type (i) Vitreous China (IS 774) for Flushing type (ii) Automatic
Flushing Cistern (IS 2326) and (iii) Plastic cisterns (IS 7231).

PVC Cisterns :

Plastic flushing cisterns for WC and Urinals shall be as per IS 7231.

The thickness of the body including cover at any point shall not be less than 2 mm for GRP and
not less than 3 mm for other plastic materials. The cistern shall be free from manufacturing
faults and other defects affecting its utility. All working parts shall be designed so as to operate
smoothly and efficiently. The cistern shall be mosquito-proof. It shall be deemed to be mosquito
proof only when there is no clearance anywhere in it which would permit a 1.6 mm diameter
wire to pass through. The outlet of each siphon or stand pipe or flush valve shall be securely
connected to the cistern by means of a lock nut. In the case of plastic siphon, it shall be
provided with suitable means of ensuring and maintaining watertight and airtight joint to the
cistern.

Flush Pipe Connection to Cistern :

The flush pipe shall be securely connected to cistern outlet and made airtight by means of a
coupling nut. The nuts made of injection-molded HDPE/Polyacetal may be used only if the end
pipe is also made of plastic. The nominal internal diameter of the cistern outset shall be not less
than 32 mm and 38 mm for high-level and low-level cistern respectively.

Inlet and Overflow Holes :

The cistern shall be provided with inlet and overflow holes, situated one at each end, which
shall be capable of accommodating overflow pipe of not less than 20 mm nominal bore and a
15 mm size float valve. The holes shall be cleanly moulded or drilled and the adjacent surfaces
shall be smooth.

Float Valves :

Signature of Contractor 166


The float valves shall be 15 mm nominal size and shall conform to IS 1703 or IS 12234 or IS
13049.

Operating Mechanism Lever :

The operating mechanism/lever shall not project beyond the side of the cistern for a distance
greater than 350 mm measured from the center of the cistern to the end of the lever arm. The
lever arm shall be provided with a suitable hole near the end through which a split ring or S-
hook can be inserted. A string (chain) shall be attached to the ring or hook. When S-hook is
employed, it shall be effectively closed after assembly to prevent accidental disconnection.

In the case of low-level cisterns, where the mechanism is handle operated, the handle, whether
situated of the front or at the end of the cistern, shall be within the projection limit. Particular
attention shall be given to the case of operation of the handle.

Finish :

The surface of cistern including cover shall be free from blisters and delamination, and
reasonably free from flow lines, streaking or colour variations. The cistern and cover shall be
opaque to light.

Operational and Performance Requirements :

Flushing Arrangement :

The cistern under working conditions and with the float valve in closed position shall operate on
a single operation of the operating mechanism/lever without calling for a sudden jerk in pulling.
If a valve is used instead of siphon for flushing purposes, the valve shall be completely leak
proof.

Working Water Level :


The working water level shall be a minimum of 6.5 cm below the effective top edge of the
cistern and shall be legibly and permanently marked on the inside of the cistern. Effective top
edge shall be taken on edge after top of the body without considering bead.

Freedom from Self Siphonage :

The siphonic system shall be capable of being rapidly brought into action when the water is at
the working water level, but shall not self siphon or leak into the flush pipe when the water is
up to 1 cm above the invert of the overflow pipe.

Reduced Water Level :

The discharge shall operate satisfactorily when the cistern is filled to a level up to 1 cm below
the working water level.

Discharge Capacity :

When tested in accordance with IS 7231, cistern of 5 litres and 10 litres capacities, when
required to give a full flush, shall respectively discharge 5 litres and 10 litres with variation of

Signature of Contractor 167


+ 0.5 litres. Dual flush cistern of 6/3 litres capacity shall discharge 6 + 0.5 litres and
alternatively a half flush of 3 + 0.5 litres.

Discharge Rate :

When tested in accordance with IS 7231, the discharge rate shall be 10 + 0.5 litres within 6
seconds and 5 + 0.5 litres within 3 seconds for cistern of capacities 10 litres and 5 litres and 6
+ 0.5 litres within 6 second and 3 + 0.5 litres within 3 second for cistern of 6/3 litres capacity
respectively. The cistern shall be so designed that there is no appreciable variation in the force
of the flush during the discharge of the required quantity of water. For coupled cisterns, this
test shall not be applicable.

Mode of measurement and payment :

The rate shall include all materials, tools , plants and labours involved in satisfactory completion
of work as prescribed above. The rate shall be paid per one No. basis

Item No.-92: (For Schedule B)

Providing and fixing 15mm dia. brass screw down stop tap of approved quality
including fixing in pipeline etc. complete as directed by Engineer In charge.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials : The brass screw down stop cock of specified dia shall conform to IS. :
781 -1977 The stop cock shall be of tested quality.

2.0 Workmanship

The stop cock shall be fixed in position by means of Jam nut and socket. The stop cock shall be
fixed near the inlet of the water meter or as directed. The joints shall be done with white zinc
and spun yarn. The joint shall be tested for leak proofing.
3.0. Mode of measurements and payment

3.1. The rate includes cost of all labours, materials, tools and plant etc. required for
satisfactory completion of this item.

3.2. The rate shall be for a unit of One number.

Item No.-93: (For Schedule B)

Providing and fixing 15mm dia. brass polished bright screw down bib taps in
pipeline of approved quality etc. complete as directed by Engineer In charge.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

Signature of Contractor 168


1.0. Materials : 15 mm. dia. brass screw down with bright polished finished shall conform
to I.S. 781-1977. The bib cock shall be best Indian make and of approved quality.

2.0. Workmanship

2.1. The screw down bib cock 15 mm. as specified above shall be fixed as directed. The
threaded portion shall be smeared with white or red lead and around with a few turns of fine
spun yarn round the screwed end of the pipe. The bib cock shall be then screwed and fixed to
water tight position.

3.0. Mode of measurements and payment

3.1. The rate includes cost of all labour, materials, tools and plant etc. required for
satisfactory completion of this item.

3.2. The rate shall be for a unit of One Number.

Item No.-94: (For Schedule B)

Providing and fixing 50mm dia. gun metal check or non return full way wheel valve
in pipeline of approved quality etc. complete as directed by Engineer In charge.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials : The gun metal check or not return full way wheel valve or specified dia,
shall conform to I.S. :778-1964. The non-return valve shall be of tested quality.

2.0. Workmanship

2.1. The gun metal check or non return valve shall be fully cleared of all foreign matter
before fixing. The fixing of shall be done by means of bolts nuts and 3 mm. rubber insertions
with flags of spigot and socketed tail pieces, drilled to the same specifications as in case of
socket and spigot flanges in case of flanged pipes. The joining shall be done leak proof.

3.0. Mode of measurements and payment

3.1. The rate includes all labours, materials, tools and plant etc. required for satisfactory
completion of this item.
3.2. The rate shall be for a unit of One number.

Item No.-95: (For Schedule B)

Providing and fixing 40mm dia. gun metal check or non return full way wheel valve
in pipeline of approved quality etc. complete as directed by Engineer In charge.

Signature of Contractor 169


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials : The gun metal check or not return full way wheel valve or specified dia,
shall conform to I.S. :778-1964. The non-return valve shall be of tested quality.

2.0. Workmanship

2.1. The gun metal check or non return valve shall be fully cleared of all foreign matter
before fixing. The fixing of shall be done by means of bolts nuts and 3 mm. rubber insertions
with flags of spigot and socketed tail pieces, drilled to the same specifications as in case of
socket and spigot flanges in case of flanged pipes. The joining shall be done leak proof.

3.0. Mode of measurements and payment

3.1. The rate includes all labours, materials, tools and plant etc. required for satisfactory
completion of this item.

3.2. The rate shall be for a unit of One number.

Item No.-96: (For Schedule B)

Providing and fixing 25mm dia. gun metal check or non return full way wheel valve
in pipeline of approved quality etc. complete as directed by Engineer In charge.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials : The gun metal check or not return full way wheel valve or specified dia,
shall conform to I.S. :778-1964. The non-return valve shall be of tested quality.

2.0. Workmanship

2.1. The gun metal check or non return valve shall be fully cleared of all foreign matter
before fixing. The fixing of shall be done by means of bolts nuts and 3 mm. rubber insertions
with flags of spigot and socketed tail pieces, drilled to the same specifications as in case of
socket and spigot flanges in case of flanged pipes. The joining shall be done leak proof.

3.0. Mode of measurements and payment

3.1. The rate includes all labours, materials, tools and plant etc. required for satisfactory
completion of this item.

3.2. The rate shall be for a unit of One number.

Item No.-97: (For Schedule B)

Signature of Contractor 170


Providing & fixing 75 mm dia. PVC " Cowl Vent" of ISI make of working pressure 4
Kg/sq.cm. with adhesive solvent cement etc. in true line and level etc. complete as
directed by Engineer In charge.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

Materials:

The cowl vent and necessary fittings shall be of rigid P.V.C. and of approved brand and quality
having required thickness uniform internal diameter of 75 mm without any defect having
capacity of 4 kg/sq.cm. internal pressure. The jointing materials for pipe i.e. adhesive solvent
cement shall be of approved quality and it shall be such that by applying / using it 100% water
proof joints can be obtained.

Workmanship :

The cowl vent shall be fitted to pipe line with help of white lead or required material, the joint
shall be leakproof and no water seepage shall be allowed.

Mode of measurement and payment :

The rate shall include all materials, tools, plants and labour involved in satisfactory completion
of work as prescribed above. The rate shall be paid per one No. basis

Item No.-98: (For Schedule B)

Providing & fixing 110 mm dia. PVC " Cowl Vent" of ISI make of working pressure
4 Kg/sq.cm. with adhesive solvent cement etc. in true line and level etc. complete as
directed by Engineer In charge.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

Materials:

The cowl vent and necessary fittings shall be of rigid P.V.C. and of approved brand and quality
having required thickness uniform internal diameter of 110 mm without any defect having
capacity of 4 kg/sq.cm. internal pressure. The jointing materials for pipe i.e. adhesive solvent
cement shall be of approved quality and it shall be such that by applying / using it 100% water
proof joints can be obtained.

Workmanship :

The cowl vent shall be fitted to pipe line with help of white lead or required material, the joint
shall be leakproof and no water seepage shall be allowed.

Signature of Contractor 171


Mode of measurement and payment :
The rate shall include all materials, tools, plants and labour involved in satisfactory completion
of work as prescribed above. The rate shall be paid per one No. basis

U.P.V.C. Pipes

Pipes shall conform to IS 13592 : 1992 (Type A). The internal and external surfaces of the pipes
shall be smooth and clean and free from grooving and other defects. The end shall be clearly
cut and shall be square with the axis of the pipe. The end may be chamfered on the plain sides.
Slight shallow longitudinal grooves or irregularities in the wall thickness shall be permissible
provided the wall thickness remain within the permissible limit.

Colour of Pipe :

Surface colour of the pipes shall be as specified.

Marking :

Each pipe shall be clearly and indelibly marked with the following information at intervals not
more than 3 metre.

(a) Manufacturer‟s name or trade mark.


(b) Nominal outside dia of pipe.
(c) Type „A‟
(d) Batch number.
The pipe may also be marked with standard mark.

Dimensions :

UPVC water pipes shall be of the dia, as specified and shall be in nominal lengths of 2,3,4 or 6
metres either plain or with sliding / grooved socket, unless shorter lengths are required at
junctions with fittings. The sizes, weights, sockets and tolerances of pipes shall be as shown in
Table 1,2,3 & 4. Tolerance on specified length shall be + 0.10mm.

TABLE -1
DIMENSIONS OF PIPES
(All dimensions in mm)
Outside Diameter at any Wall Thickness
Nominal Outside Mean Outside Diameter
Point S Type A
Diameter
Min Max Min Max Min Max
75 75.0 75.3 74.1 75.9 1.8 2.2
100 110.0 110.4 108.6 111.4 2.2 2.7

TABLE -2
MINIMUM WALL THICKNESS OF SOCKETS ON PIPES
(All dimensions in mm)

Nominal Outside Diameter S 2 Min Type A S 3 Min Type A


75 1.6 1.0
Signature of Contractor 172
110 2.0 1.2

TABLE -3
DIMENSIONS FOR SLIDING SOCKETS
(All dimensions in mm)
Nominal Outside Socket Dept, C Mean Inside Diameter of Socket at Midpoint, DI
Diameter Min Max
75 40.0 75.1 75.3
110 48.0 110.1 110.4

TABLE -4
DIMENSIONS OF GROOVED SOCKET
(All dimensions in mm)
Nominal Inside Diameter of Inside Diameter of Length of Neck of Length
Outside Socket, D1 Beading, D2 Beading Socket beyond
Diameter and Neck beading
A B C
Min Max Min Max Min Max Min
75 75.3 76.2 84.5 85.5 20 5 35
110 110.4 111.3 120.3 121.3 26 6 32

Fixing and Jointing

Pipes shall be either fixed on face of wall or embedded in masonry as specified.


Plain pipes shall be secured to the walls at all joints with PVC pipe clips by means of 50 x 50x
50 mm hard wood plugs, screwed with MS Screws of required length including cutting brick
work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand). The clips shall be kept about
25mm clear off finished face of wall, so as to facilitate cleaning of pipes.

Pipes shall be fixed perfectly vertical or to the lines as directed. The pipes shall be fitted to
fittings with seal ring conforming to IS : 5382 allowing 10mm gap for thermal expansion.

Installation in Wall/Concrete:

The walls/concrete slots should allow for a stress free installation. Pipes and fittings to be
inserted into the slots without a cement base, have to be applied first with a thin coat of PVC
solvent cement followed by sprinkling of dry sand (medium size) and then allowed to dry. The
process gives a sound base for cement fixation. This process is repeated while joining PVC
material to CI/AC materials.

Fittings :

Fittings used shall be of the same make as that of the PVC pipes and shall have a minimum wall
thickness of 3.2mm. The fittings shall be supplied with proved socketted ends with square
groves and provided with Rubber Gasket conforming to IS : 5382. The plain ends of the fittings
should be chamfered. The fittings shall be joined with the help of Rubber lubricant.

Note : These pipes shall be used only in shaft or unexposed location to avoid damage to these
pipes due to willful act.
Signature of Contractor 173
Method of Measurement And Payment

The measurement shall be recorded in running meter of pipe length laid along the centerline of
axis of pipeline including tees, enlarges, reducers and bends, correct up to 0.01 m length. No
payment shall be made for overlaps etc. The payment shall be made after completion of whole
made item as mentioned in price bid on Running Meter basis and 15% shall be withheld for
satisfactory hydraulic testing.

The rate includes cost of all materials, tools, plants and labour involved in satisfactory
completion of work as specified above.

The rate shall be for a unit of one Rmt of actual work done.

CONCELAED UPVC pipes,

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

The item shall be carried out & paid as per specification -99 described as above. The diameter
of pipe shall be 15 mm.

50mm dia & 30cm length G.I. rainwater spout

1.0. Materials : G.I.M.S. type of 50 mm. dia. shall conform to M-56.

2.0. Workmanship

2.1. The G.I. pipe of 30 cms. fixed as rain water pipe as directed. The pipe shall be fixed
about 1/4 dia. below the floor level so as to make approach of water easy. The inlet of pipe
shall be rounded off for easy entry of rain water pipe. The pipe shall be fixed in C.M. 1:1.

3.0. Mode of measurements & payment

3.1. The rate includes of all labour and materials required for satisfactory completion of this
item.

3.2. The rate shall be for a unit of One number.

Item No.-103: (For Schedule B)

P.V.C. " Nahni trap"


.

Materials :
The Nahni trap and necessary fittings shall be of rigid PVC and of approved brand and quality
having required thickness uniform internal diameter without any defect having capacity of 4

Signature of Contractor 174


Kg/Sq.cm. internal pressure. the jointing materials for pipe i.e adhesive solvent cement shall be
of approved quality and it shall be such that by applying / using it 100 % water proof joints can
be obtained.

Workmanship :
The Nahni trap shall be fitted in pipe line with help of white lead or required material, the joint
shall be leak proof and no water seepage shall be allowed.

Mode of measurement and payment :


The rate includes cost of all materials, tools, plants and labour involved in satisfactory
completion of work as specified above.
The rate shall be paid per one No. basis.

Flat back long pattern urinal


1.0. Materials: The white earthenware flat back long pattern type urinal of size 635 mm.
x 395 mm. x 420 mm. shall conform to M-64.

2.0. Workmanship

2.1. The urinals shall be fixed in position by using wooden plugs and screws and shall be at
a height 65 cms. From the floor level to the top of the lip of urinal, unless otherwise directed
including urinal flush valve 15 mm size control cock with 300 mm long connecting CP
pipe and nuts and PVC waste coupling and concealed waste pipe. The wooden plugs shall
be of 50 mm. x 50 mm.at base tapering to 38 mm. x 38 mm. at top 50 mm. in length shall
be fixed in wall in steel waste pipe which shall discharge in the channel or floor a tap. The
connection between the urinal and flush or waste pipe shall be made by means of putty or
white lead mixed with chopped hemp.

3.0. Mode of measurements and payment

3.1. The rate shall includes cost all labours, materials, tools and plants etc. required for
satisfactory completion of this item.

3.2. The rate shall be for a unit of One number.

Vitreous China "Wash basin" of size 550 mm X 400 mm

1.0. Materials

1.1. The white glazed earthenware wash basin shall be 550 mm. x 400mm. of 1st quality and
make as approved by the Engineer-in-charge. The wash basin shall-conform to M-59. The C.P.
brass trap and unions shall be of 32 mm. dia. and of best quality and make as approved by
the Engineer-in-charge The rubber plug for sink or wash hand, basin shall be best quality and
make as approved by the Engineer-in-charge.

2.0. Workmanship

2.1. The washbasin shall be fixed on the wall as and where directed. The wash basin shall be
supported on a pair of M.S. or C.I. brackets fixed in C.M. 1:3 (1 cement : 3 sand). The bracket
shall conform to I.S. : 775-1962. The wall plaster on the rear shall be cut to rest the top edge

Signature of Contractor 175


of the washbasin. After fixing the basing, plaster shall be made good and surface finished to
match the existing one.

2.2. The brackets shall be painted white with ready-mixed paint.

2.3. The C.I. brass trap and union shall be connected to 32 mm. dia. waste pipe
which shall be suitably bent towards the wall and which shall discharge into an open drain
leading to a gully trap or direct in to gully-trap on the ground floor and shall be connected to a
waste pipe through a floor trap on the upper floors. C.P. brass trap and union may not be
provided where the surface drain or a floor trap is placed directly under the basin
and the waste is discharged in to vertically.

C.P. brass waste trap and union shall be connected to 40 mm dia waste pipe which shall be
suitably bent towards the wail which shall discharge into drain through a floor trap The C.P
brass waste trap shall be provided for wash basin or sink as the case may be. The rubber plug
with plain shall be fixed in wash basin or sink as directed.

2.4. The height of the front edge to the wash basin from the floor level shall be 80 cms.

2.5. The necessary inlet, outlet connections and fittings such as pillar cocks, CP dress waste
trap waste pipe, stop cock, chain wish rubber plug etc. shall be fixed.

2.6. The payment of fittings shall be made separately under separate items.

3.0. Mode of measurements & payment

3.1. The rate includes cost of all labour, materials, tool and plant etc. required for
satisfactory completion of this item as specified in workmanship.

3.2. The rate shall be for a unit of One number.

pillar taps, capstan head screw down high screws, shanks & back nuts.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials : The capstan head pillar tap of specified dia. of C.R over brass shall be
best quality and shall conform to I.S. : 1975 - 1961. The pillar taps shall be tested quality.

2.0. Workmanship

2.1. The capstan head pillar tap of specified dia. shall be fixed as directed with
required washers of selected leather or rubber asbestos composition or of plastic as directed.
The cock shall fixed with pipe line white Zink end spun yarn, to make joint water tight. The
work shall be carried out in best workman like manner.

3.0. Mode of measurements and payment

Signature of Contractor 176


3.1. The rate shall be for a unit of one number.

beveled edge mirror of superior glass mounted


1.0. Materials

1.1. The 600 mm. x 450 mm. size mirror shall be of superior glass with edge rounded offer
beveled as specified. It shall be free from flaws specks, or bubbles and its thickness shall riot be
less than 6 mm. The glass for the mirror shall be uniformly silver plated at the back and shall be
free from silvering defects Silvering shall have a protective uniform covering of red load paint.
The 6 mm thick ply wood shall conform to M-37. The 6 mm. thick A.C. sheets shall conform to
M-24.

2.0 Workmanship :

2.1. The mirror of 600 mm. x 450 mm. size mounted on A.C. Sheet or plywood 6 mm thick
with C.P. brass clips shall be fixed as directed, by fixing wooden plugs in wall and C.P
brass screws and washers. The work shall be carried out in best workman like manner.

3.0. Mode of measurements & payment

3.1. The rate includes cost of all labour and materials, tools and plant etc. required for
satisfactory completion of this item. The rate shall be for a .unit of One number.

Item No.-108: (For Schedule B)

Providing and fixing 600 mm X 200 mm size C.P. brass towel rail complete with C.P.
brass brackets fixed to wooden plugs with C.P. brass screws etc. complete as
directed by Engineer In charge.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1.0. Materials

1.1. The C.P. brass towel rail shall be 600 x 20 mm. of best quality as approved by the
Engineer-in-charge The brackets shall be of C.P. brass. The rail shall conform to I.S. 1068-1958.

2.0. Workmanship

2.1. The brackets of the towel rail shall be fixed by means of C.P. brass screws to wooden
firmly embedded in the wall with C.M. 1:3 (1 cement : 3 coarse sand). The towel rail shall be
fixed as and where directed.

3.0. Mode of measurements and payment

3.1. The rate includes cost of all labour and materials, tools and plant etc. required for
satisfactory completion of this item.

Signature of Contractor 177


3.2. The rate shall be for a unit of One number.

Item No.-109: (For Schedule B)

Kitchen sink with drain board 510 x 1040 mm bowl depth 225mm

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
/GWSSB, relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

The stainless steel kitchen sink for domestic purpose shall be provided as per IS : 13883-1984
or latest code. Sinks may be supplied with a bright or dull finish, as desired by the owner.

Types of sinks :

The sink shall be one of the following types :

Type A1 or A2 : Single bowl without drainer


Type B1 or B2 : Double bowl without drainer
Type C : Single bowl single drainer, right or left hand
Type D : Single bowl single drainer
Type E1, E2 or E3 : Double bowl single drainer, right or left hand
Type F : Double bowl double drainer

Note : Hand of sink refers to position of drainer when viewed from the front.

Dimensions and Tolerances


Thickness of Sheet / Strip

Nominal thickness of stainless steel sheet / strip used in the construction of sink shall be not
less than 1.00 mm before forming. Thickness at any point of sink, after forming shall not be
less than 0.75 mm.

Depth of Bowls
The depth of the sink bowl shall be 150 mm minimum, when measured from the top edge of
the bowl to the base of the sink.

Internal Dimensions of Bowls

The minimum internal dimensions, when measured on the bowl centre lines across the top of
the bowl, shall be 380 mm x 340 mm for rectangular bowls and 360 mm for round bowls.

Notes :

(1) There is no restriction on bowl shape provided the minimum dimensions given in this
clause are complied with.

(2) Internal width of smaller bowl shown in Fig. 1 for Type E2 and E3 may be reduced as
per the manufacturer‟s design.

Signature of Contractor 178


Sit on Sink

A sink which when installed fits on top of the lines up with a base unit of suitable dimensions,
such that the aprons of the sink form a continuation of the sides of the base unit.
Inset Sink

A sink which is constructed to fit into an aperture in a work top so that when installed, it only
projects above the working surface by an amount equal to the edge formed thickness.

Bowl Locating Limits

The distance between the edge of the sink bowl and the end of the sink shall be 15 mm
minimum for sit-on type sinks and 30 mm minimum for inset type sinks. Depth of the collar
provided for inset sinks shall be 10 + 2 mm.

For sinks designed for use with a 600 mm wide worktop, the distance between the edge of the
sink bowl and the front of the sink shall be 50 mm minimum and in the case of sinks designed
for use with 500 mm wide worktop, the distance shall be 45 mm minimum.

Both single and double bowl sink shall be set a minimum of 10 mm from gridline.

Workmanship of Sink :

Sinks shall be constructed of the lowest practical numbers of sections compatible with the
manufacturing practice to ensure a smooth surface. The surface shall be free from any sharp
edges. Sink bowl shall have rounded corners to facilitate cleaning. Folded corners may be
drawn or welded. All welded surfaces shall be adequately cleaned off inside and outside the
sink.

The edges of any holes in the sink shall not show evidence of undulation, chips, cracks or any
other defect which would impair its appearance or performance.

When examined by an unaided eye of an experienced observer, from a distance of 600 + 100
mm from exposed surfaces, the sink shall be free from visible defects.

The visual examination shall be carried out with uniform illumination at the surface of the sink
of 300 lux and with the sink positioned so that it is between the light source and the observer.
Drainers shall be fluted or grooved and shall be inclined towards the sink bowl.

Waste Outlet

Sink bowls shall be deigned / constructed with a fall to the waste outlet. The waste outlet fitting
shall be recessed type.

Tap Holes

Sinks shall be provided, in one of the following conditions :

(a) Without tap holes;

Signature of Contractor 179


(b) With two tap holes of 30 + 2 mm diameter with a distance of 180 + 2 mm between
centres, or 300 + 2 mm between centres for round bowled sinks only, for nominal size 1/2
outlet pillar or high level combination taps;
(c) With single tap hole of 35 + 2 mm min. diameter for high outlet mixer tap.

The centres of tap holes shall be more than 60 mm from the nearest back edge of the bowl and
not less than 50 mm to the front face of the upstand.

Overflows

Sinks shall be provided in either of the following conditions :

(a) Without an overflow hole;


(b) With an overflow hole having a horizontal dimension not greater than 64 mm, and a
vertical height not less than 15 mm giving an area of not less than 640 mm2, and located
completely below the spillover level of the sink.

Workmanship :

The readymade Stainless steel Kitchen sink of approved make and design as per IS : 13983
shall be fixed on C.I Brackets with screws in perfect line, level. The brackets shall be painted
with a coat of primer and two coats of oil paint. The work shall be carried out as directed by
Engineer in charge.

Mode of measurement and payment :

The rate including cost of all materials, tools, plants and labour involved in satisfactory
completion of work at above specified levels.

The rate shall be for unit of number as per actual work done.

The work shall be carried out as per detailed drawings and as directed by EIC.
Measurement shall be in number of actual work done.

S.W. gully trap with C.I. grating brick masonary chamber

1.0. Materials : (t) Water shall conform to M-1. (2) Cement mortar of proportion 1:5
shall conform to M-11. (3) Burnt brick shall conform to M-15. (4} The S.W. Galley trap of 150
mm. x 100 mm. size shall confirm to .M-70.

2.0. Workmanship

2.1. Excavation for gulley trap shall be done true to dimensions and levels as indicated on
plans or as directed. The excavation work shall generally be done as per relevant specifications
of item 4.0.0.of earth work.

2.2. Fixing:

Signature of Contractor 180


2.2.1. The gully trap shall be fixed over cement concrete 1:5:10 (I cement : 5 sand : 10
graded brick bats aggregate 40 mm nominal size) foundation. 650 square and 100 mm. thick
The depth of top of concrete below the ground level shall be 675 mm. The jointing of gulley
outlet to the branch drain shall be done similar to jointing of S.W. pipe a s described in item
No. 24.1 (A).

2.3. Brick masonry chamber : After fixing and testing gulley and branch
drain, a brick masonry 300 x 330 mm. inside with bricks in CM 1:5 (1 cement : 5
sand) shall be built with a 100 mm. brick work round OH; gulley trap from the top of
bed concrete up to ground level. The space between the chamber walls and the trap shall be
filled with cement concrete 1:5:10. The upper portion of the chamber i.e. above the top level
of the trap shall be plastered inside with cement mortar 1:3 (1 cement: 3 sand) finished with
floating coat of neat cement. The corners and bottom of the chamber shall be rounded of so as
to slope towards the grating.

2.4. C.I. cover with frame 300 mm, x 300 mm. (inside) size shall then be fixed on the top of
the brick masonry with C.C. 1:2:4 ( 1 cement : 2 coarse sand : 4 graded aggregate 20 mm.
nominal size) 40 mm. thick and rendered smooth. The finished top of the cover shall be left
about 40 mm. above the adjoining ground level so as to exclude the surface water from
entering the gulley trap.

3.0. Mode of measurements & payment

3.1. The rate includes cost of all labour, materials, tools and plant etc. required for
satisfactory completion of this item as described above.

3.2. The rate shall be for a unit of one number basis.

H.D.P.E ( SINTEX ) single wall construction

Material :
Polythylene used for manufacture of tanks and manhole lids may be high density (HDPE), low
density (LDPE) of linear low density (LLDPE) and shall confirm to IS 10146. Polyethylene shall
be compounded with carbon black so as to make the tank resistant to ultra violet rays from the
sun. The percentage of carbon black content in

Polythylene shall be 2.5 + 0.5 percent and it shall be uniformly distributed. The materials used
for the manufacture of tank, manhole lid and fittings shall be such that they neither
contaminate the water nor impart any taste, colour, odour or toxity to water.

Manufacture and Finish :


The tanks shall be manufactured by rotational moulding process. Each tank and the manhole lid
shall be single piece having arrangement for fixing and locking the manhole lid with tanks.
Excess material at the mould parting line and near the top rim shall be neatly cut and finished.
The internal and external surface of the tanks shall be smooth, clean, and free from hidden
internal defects like air bubble, pit and metalic or other foreign material inclusion. Capacity of
the tank, minimum weight of the empty tank ( without manhole lid ) and the manufacture
brand name shall be embossed on the top surface of the tank near manhole.

Signature of Contractor 181


Shape, Size and Capacity :
The tank shall be cylindrical vertical with closed top having a manhole. The diameter and height
of the tank of various capacities shall be as per manufacturer's specifications and a clearance
of + 3 percent shall be permitted on these dimensions. Capacity of the or upto the bottom of
the inlet location which ever is less. Capacity of the tank shall be specified. Extra capacity if any,
shall be ignored.

Weight and Wall Thickness :


Minimum weight of the empty tank ( exclusive of manhole lid fittings ) and the minimum wall
thickness of top, bottom and sides shall be specified. Wall thickness shall be checked beyond
150 mm of the edge where the direction the plane of tank surface changes.

Installation and fittings :

The flat base of the tank shall be fully supported over its whole bottom area on a durable rigid
flat and level platform sufficiently strong to stand without deflection the weight of the tank
when fully filled with water. Depending upon the capacity and location tanks may be suitably
anchored as per the directions of the Engineer in charge. For inlet, outlet and other connections
fully threaded GI HDPE or PVC connections with hexagonal checknuts and washers on either
side of the tank wall shall be provided. Holes for threaded connections shall be drilled and not
punched. Pipes entering of leaving the tank shall be provided with union and suitably supported
on a firm base to avoid damage to the tank walls.

Manhole lid :

The lid shall rest evenly and fit over the rim of the manhole so as to prevent the ingress of any
foreign matter in to the tank. The lid shall be provided with suitable arrangement for looking it
with the tank.

Rate :

The rate shall include the cost of tank, manhole lid, carriage and delivery at the place specified.
Hoisting, installation, fittings, platform and anchoring shall be payable separately.
The rate shall be paid per one Litre basis
Item No.-114: (For Schedule B)

SEPTIC TANK OF 3m x 0.9m x 1.5m depth


Material :

Different materials used in the items shall confirm to as describe below:

Water : M-1 (1.1 to 1.5 /), Cement : M-3 (3.1 /), Sand : M-6 (6.1 to 6.3 /), Cement mortar : M-
11 (11.1 to 11.3.2 /), Brick aggregate : M-14 (14.1 to 14.2 ), Brick : M-15 (15.1 to 15.5 ), Mild
steel : M-18 (18.1 to 18.3), Tor steel : M-19 (19.1 to 19.2), C.I. pipe : M-68 (68.1 to 68.4.3).
C.I. cover of 60cm x 45cm size and C.I. cowl vent of 75mm dia shall be approved quality.

Workmanship :

Signature of Contractor 182


Different items covered in the above work shall confirm to as specified in a detailed
specification as specified below. Excavation up to 1.5m depth in loose or soft soil: Item no.
4.0.0 (A) (1.0 to 5.2 /), Excavation from 1.5m to 3.0m depth in soft rock: Item no. 4.001 (D)
(1.0 /), Brick masonary in C.M. 1:6 : Item no. 6.13 (B) (2.0 to 2.1), B.B.C.C. 1:5:10 : Item no.
5.3.8 (A) (2.0 to 2.1), R.C.C. 1:2:4 slab : Item no. 5.003 (III) (1.0 to 1.1), Half brick masonary
in C.M. 1:4 : Item no. 6.30.1 (B) (1.0 to 1.1), Mild steel reinforcement : Item no. 5.4.10 (2.0 to
2.8), Tor steel reinforcement : Item no. 5.4.11 (2.0 to 2.1 /), 15mm th. Smooth plaster in C.M.
1:4 : Item no. 17.58 (II) (1.0 to 1.1 /) (Read 15mm th. Smooth plaster instead of 10mm th.
Smooth plaster), 40mm th. I.P.S. (1:2:4) flooring : Item no. 14.71 (A) (2.0 to 2.3 / P.88 / V.1),
Cement vata in C.M. 1:1 Item no. 17.0.0.1 (2.0 to 2.1), 75mm Dia, C.I. pipe: Item no. 23.79
(B) (2.0 to 2.7), 60cm x 45cm size C.I. cover : Item no. 23.00.6 (2.0 to 2.1) and 75mm dia C.I.
cowl: Spec. no. 18) (Read 75mm dia C.I. cowl instead of 75mm PVC cowl).

Mode of measurement and payment :

The rate shall include excavation & all materials, tools, plants, formwork and labour involved in
satisfactory completion of work as prescribed as above.

The rate shall be paid per one number basis as per actual work done.
Measurement shall be in number of actual work done.

SOAK WELL OF 2.5M internal dia


Material :

Different materials used in the items shall confirm to as describe below:

Water : M-1 (1.1 to 1.5), Cement : M-3 (3.1 /), Sand : M-6 (6.1 to 6.3 /), Cement mortar : M-11
(11.1 to 11.3.2 /), Brick aggregate : M-14 (14.1 to 14.2 /), Stone coarse aggregate : M-12 12.1
to 12.3), Brick : M-15 (15.1 to 15.5), Mild steel : M-18 (18.1 to 18.3), Tor steel : M-19 (19.1 to
19.2), C.I. pipe : M-68 (68.1 to 68.4.3). C.I. cover of 60cm x 45cm size and C.I. cowl vent of
75mm dia shall be approved quality.

Workmanship :

Different items covered in the above work shall confirm to as specified in a detailed
specification as specified below. Excavation up to 1.5m depth in loose or soft soil: Item no.
4.0.0 (A) (1.0 to 5.2 /), Excavation from 1.5m to 3.0m depth in soft rock: Item no. 4.001 (D)
(1.0 ), Excavation from 3.0m to 5.0m depth in soft rock : Item no. 4.002 (D) (1.0 to 1.1), Brick
masonary solid & honey comb : Item no. 6.13 (B) (2.0 to 2.1), R.C.C. 1:2:4 slab : Item no.
5.003 (III) (1.0 to 1.1), Mild steel reinforcement : Item no. 5.4.10 (2.0 to 2.8), Tor steel
reinforcement : Item no. 5.4.11 (2.0 to 2.1), 75mm Dia, C.I. pipe: Item no. 23.79 (B) (2.0 to
2.7), 60cm x 45cm size C.I. cover : Item no. 23.00.6 (2.0 to 2.1) and 75mm dia C.I. cowl: Spec.
no. 18 / V.2) (Read 75mm dia C.I. cowl instead of 75mm PVC cowl). Brick aggregate of 40mm
nominal size shall be filled up to the pit upto 1.50 m depth / height as directed by Engineer in
charge.

Mode of measurement and payment :

The rate shall include excavation and all materials, tools, plants, formwork and labour involved
in satisfactory completion of work as prescribed as above.

Signature of Contractor 183


The rate shall be paid per one number basis as per actual work done.
Measurement shall be in number of actual work done.

Carrying out plinth treatment to post construction

1.0. Materials : The chemicals used for the soil treatment shall be only one of the
following with concentration shown against each in aqueous emulsion.

Chemicals Concentration
1. Aldrin 0.50% (by weight)
2. Heptachlor 0.50% (by weight)
3. Chlordane 1.00% (by weight)

2.0. Workmanship

2.1. The chemicals barrier shall be complete and continuous under whole of the structure to
be protected.

2.2. The bottom and the sides of foundations up to a height of 30 cms. from
the bottom of excavation made for masonry foundation and for basement column pits
shall be treated with the chemical emulsion at the rate 5 liters/ sq. meter of the surface
area. .
2.3. The chemical treatment shall be-carried out when the surfaces is quite dry. Chemical
treatment shall not be carried out when it is raining or when the soil wet with rain or sub soil
water.

2.4. Once formed, treated soil berries shall be not disturbed. If by chance, treated soil
barriers are disturbed, immediate steps shall be taken to restore the continuiting and
compactness of the barrier system

2.5. The treatment against termite infection shall remain fully effective for a period not
less than 10 years from date of issue of the final certificate to completion of work. If at any
time during this period, any defects in treatment are revealed or any evidence of infection in
any part of the building or structure is noticed, the contractor shall be rectify the concerned
defects within 14 days on receipt of notice from Engineer-in-charge. On contractor's failure to
do so, the Engineer-in-charge may get the same rectified through any other agency at
contractor's risk and cost, and decision of Engineer-in-charge as to the cost payable by
contractor for the same shall be final and binding to the contractor.

2.6. A guarantee bond on appropriately stamped paper shall be given by the contractor to
the department in the manner and form prescribed below:

The a b o ve specifications shall be followed e x c e pt that the top surface of the consolidated
earth
within the walls, shall be treated with the chemical emulsion at the rate of 5 liters/sq. metre
of the surface before the sand bed or sub-grade is laid. If the filled earth has been well
rammed and the surface does not allow the emulsion to seep through, holes up to 50 to 75
mm. deep at 150 mm. centers both ways may be made with 12 mm. dia. M.S. rod on the
surface to facilitate absorption of the emulsion.
Signature of Contractor 184
FORM OF GUARANTEE BOND

I/We………………………………………………………………………………. ( Contractor) hereby guarantee


that work will remain unaffected and will not be any way damaged by termite or any other
germs of similar types, for a period for 10 years after completion of the work of anti-termite as
per the terms and conditions of the contract and or damage that might be caused on account
of termite and or other similar type of germs and hereby Guarantees to make good any loss of
damages suffered by the Government of Gujarat and further guarantee to redo effective
work without claiming any extra cost.

2.7. This guarantee shall remain in force for the period of 10 years from the completion
of the work under the contract and it shall remain binding to the contractor for period of 10
years.

2.8. The deposit at the rate of 50% of the cost of this item from the running and final bills
shall be recovered and retained for the first one year after completion of the work and 10%
shall be retained for the balance of guarantee period and shall be refunded only after the
completion of the guarantee period.

3.0. Mode of measurements & payment

3.1. The length and breadth shall be measured correct to a cm. as per the dimensions of
sanctioned plans. No deduction shall be made nor extra paid for any opening for pipes etc. up
to 0.1.sq. mt. The rate shall include the cost of all labour, tools, plants and materials required
for the operation involved for satisfactory completion of this item.

3.2. The rate shall be for a unit of One sq. meter.

Item No.-118: (For Schedule B)

Boring holes 200 mm diameter by machine in ordinary soil, soft or hard murrum and
getting out the
Mode of measurement and payment :

The rate shall include cost of materials, tools, plants, and labour involved in satisfactory
completion of work as specified above.

The rate shall be for unit of one Rmt of actual work done.

Precoated galvalume sheet of trapezoidal profile


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D./
GWSSB relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

Galvalume Sheet roofing :

Galvalume sheet shall be 0.55 mm thick (total coated thickness), 550 MPa minimum, yield
strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and

Signature of Contractor 185


finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having
overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling
and self tapping screws neoprene and EPDM washers, Penetrations and laps in sheet shall be
sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close
voids between sheets, sheet & fasteners etc.

Fixing system shall be as per manufacturers‟ instructions and shall be safe against effects of
wind velocity.

Galvalume Sheet Wall Cladding :

Galvalume sheet for wall cladding shall be same as for roof and shall be fixed with 8mm and
30mm deep trapezoidal profile sheeting fixed with self trapping fasteners.

Roofing Accessories :
Roofing accessories i.e. corner piece apron, eaves/valley gutters, hoppers, ridges, sheet floor
connectors etc. shall be of galvalume sheet and of size shape as specified.

Roof Covering

Roof will be covered fully with 0.55 mm COLOURED Galvalume Sheets

Sheeting Accessories

The roof shall be provided with sheeting accessories like standard fasteners, filler strip, rope
seal and flashings including Eave Gutter and Down Spouts till ground level as per Mfg‟s
specifications and standards.

Standard Accessories and Building Additions

 Anchor Bolts : As required by Design

 Rod Bracings : Rod bracing shall be provided on the roof


for specified number of bays as required by design.

C. STANDARD SUPPLIED MATERIAL :

The following material shall also be supplied with.

1. CLOSURE STRIPS :

Closure matching the profile of the panel shall be supplied along the eave and rake.

2. SEALING TAPE :

All laps of roof panels shall be sealed with a continuous ribbon of tape sealer.

3. ROD BRACING :

Signature of Contractor 186


Diagonal rod bracing shall be supplied in the roof to brace the building against wind loads,
Rods bracing is essential for the stability of the building.

4. CONNECTION BOLTS :

High Strength Bolts shall be furnished at all primary connections, Machine bolts shall be
furnished at all secondary connections.

5. SHEETING FASTENERS :

Self tapping sheet metal screws with metal and neoprene washers shall be furnished to
fasten the sheeting to secondary members. All screws shall have hex heads, be colour
coated to match roof and wall panels, and shall be zinc plated steel.

E. ROOF SHEETING :

Roof panels shall be 0.55 mm coloured galvalume sheeting. Each panel shall
provide one meter coverage and can be shipped in any length upto 10 m.
The exterior face is pre-painted with 1 mill thick factory applied polyester paint
for white panels and siliconized polyester paint. Color of exterior face shall be as
per approval. Colour of interior face shall be white.

F. SHEETING FASTNERS :

Standard fasteners shall be self tapping sheet metal screws with metal and
neoprene washers. All screws shall have hexagonal heads, be coated to match
roof and wall sheeting and made of zinc plated steel.

G. SEALER :

This is to be applied at all side laps and end laps of roof panels and around self
flashing windows. Sealer shall be 6 mm wide x 5 mm thick, asbestos fibre filled,
pressure sensitive Butyl

Tape : The sealer shall be non asphaltic, non shrinking, non drying and non
toxic and shall have superior adhesion to metals, plastics and painted surfaces
at temperatures from –51O C to + 104O C.

I. CLOSURES :

Solid or closed cell E.T.P [Ethylene Polypropylene Terpolymer] closures matching


the profile of the panel shall be installed along the eaves, rake and other
locations specified on Mfg‟s Drawings.

J. RIDGE CAPS :

A formal panel matching the material colour, slope and profile of adjoining rib
roof panels.

K. FLASHING AND TRIM :

Signature of Contractor 187


Flashing and/or trim shall be furnished at the rake, corners, eaves, framed
openings and wherever necessary to provide weather tightness and finished
appearance. Colour for rake and eave flashings and colour of wall for corner
flashings shall be as per approval. Materials shall be 0.55 mm thick conforming
to the physical specifications of adopted country code.

WORKMANSHIP

Roofing Generally :

Particular care shall be taken in providing good workmanship in the construction of roofs,
specially the vulnerable points mentioned below to ensure that the finished roof is water-tight
without any leakage, under all weather conditions.

(a) Filling of side joints of flat terrace tiles, bricks, stone slabs etc. with mortar.
(b) Joints between roof and parapets, chimney stacks etc.
(c) Rain water outlets
(d) Waterproofing treatment
(e) Drillings of holes in corrugated and semi-corrugated sheets
(f) Avoiding cracks in fragile articles such as asbestos cement sheets, tiles etc., due to
careless handling and fixing.
(g) Sealing joints of gutters, hip and ridge coverings etc.

Sloping roofs shall be secured with suitable wind tiles where indicated. These shall be fixed with
the same hook bolt which secure the sheets to the purlin. To allow for expansion and
contraction, holes in wind ties shall as slotted, if so directed.

The slope of the finished top of flat roofs shall be as specified or indicated in the drawings.

Pre coated sheets Sheeting

Spacing of Purlins :

The spacing of purlins shall be as indicated but shall not exceed the following :

Thickness of steel sheet Maximum spacing of purlins


C/C
1.00 mm 2.00 m
0.80 mm 1.80 m
0.63 mm 1.60 m
0.55 mm 1.50 m

Laps :

The sheets shall be laid with minimum end lap of 150 mm and side lap of two corrugation as
indicated or as specified by mfg. The side and end laps may be increased to avoid cutting of
sheets, if the GE agrees thereto. Te above minimum end lap of 150 mm shall apply to slopes of
1 vertical to 2 horizontal and sleeper slopes. For flatter slopes the minimum permissible end
laps shall be 200 mm.
Signature of Contractor 188
Laying and Fixing of Sheets :

The sheets shall be laid on the purlins or other structural members as indicated, to a true plane.
With the lines of corrugations truly parallel or normal to the area to be covered, unless
otherwise required as in special shaped roofs.

Sheet shall be fixed to the purlins or other structural members with self tapping sheet metal
screws.

Where slopes of roofs are less than 1:2 ½ (1 vertical to 2-1/2 horizontal) or where indicated
sheets shall be joined together at the side laps by galvanized iron bolts and nuts 25x6 mm size,
each bolt with a bitumen and a GI limpet washer or a GI limpet washer filled with white lead.
The spacing of these seam bolts shall not exceed 20 cm.
Sheeting on steel bearers, where indicated, shall be riveted together with 6mm dia galvanized
wrought iron rivets and galvanized plain round washers (two or each rivet), at intervals not
exceeding 20 cm for the side laps and on every corrugation (staggered) fort the end laps. The
sheets may be riveted in sets of 9 to 12 on the ground and then hoisted in position. Care shall
be taken in riveting that the sheet is well supported underneath and no indentation is made on
the upper surface. Rivets shall be tightened and drawn closely and the heads spread evenly and
equally.

All holes for bolts, rivets, drive screws etc., shall be made in the crown of corrugations and shall
be drilled (and not punched). The holes in the washers shall be of the exact diameter of the
hook bolt or the seam bolt. The nuts shall be tightened from above to give a leak proof roof.

Ridges and Hips:

Ridges and hips shall be covered with ridge and hip fixtures with a minimum 150 mm lap on
either side cover the roofing sheets, and shall be properly bent to shape and fixed. The end
laps of the ridges and hips and between ridges and hips shall also be not less than 150 mm.

Valley and flashings :

Valley and flashings of plain sheeting shall be of width and thickness as specified and bent to
shape and fixed. They shall lap with the corrugated sheets not less than 150 mm width on
either side. The end laps of valleys and flashing shall also be not less than 150 mm and painted
with red lead.

Valley sheets shall be fixed to the roof members below, with the same 8 mm dia GI hook bolts
and nuts and bitumen and GI limpet washers which fix the sheets to those roof members. At
least one of the fixing bolts shall pass through the end laps of the valley pieces, on either side.
If this is not possible extra hook bolts shall be provided. The edges of valleys and flashing shall
be straight from end to end. The surfaces shall be true and without bulges and depressions.

Flashing shall be well and properly tucked into joints of brickwork of masonry, secured with
hardwood wedges and the joints finished neatly to match the adjoining work.

Gutters :

Signature of Contractor 189


Gutters shall be laid with a minimum fall of 1 in 150, which should be increased where possible.
The gutters shall be true to line and slope. Gutters shall be laid with the requisite accessories
such as drop ends stop ends, nozzle angles and union clips as directed. The size of the outlet of
drop ends and nozzles shall, be the same as the size of rainwater pipes into which they
discharge.

Joins in the gutters shall be made watertight.

Unless otherwise indicated, gutters shall be supported with a brackets close to the socket and
another in the centre of the gutter. Plain ended gutter shall be supported with bracket on either
side of each joint. For gutters of large size, one extra supporting bracket in the centre of the
gutter shall be fixed.

Brackets shall be fabricated from mild steel flats of the size as indicated. Where the brackets
are fixed to the side of rafters they shall be fixed with 40x3 mm flats bent to shape and fixed
rigidly to the sides of rafters with 3 nos. 10 mm dia bolts, nuts and washers. The bracket shall
overlap the rafter not less than 30 cm and connecting bolts shall be 115 mm centres.
Where the brackets are to be fixed to the purlins, these shall consist of 50x3 mm MS flats bent
to shape with one end turned at a right angle and fixed to the purlins face with a 10 mm dia
bolt, nut and washer. The perpendicular over-hang portion of 50x3 mm bracket shall be
stiffened by another 50x3 flat bent to right angle shape with its longer leg connected to the
bracket with 2 numbers 6 mm dia MS bolt, nuts and washers and its shorter legs fixed to the
face of purlins with one number 10 mm dia bolt, nut and washer. The over-hang of the vertical
portion of the flat iron bracket from the face of the purlins shall not exceed 225 mm.
The requisite slope in the gutters shall be given in the line of bracket. The brackets shall be
placed at not more than 90 cm centres for AC gutters and 75 cm for sheet metal gutters.

Jointing and Fixing of Steel Gutters :

Use of stays :

Unless otherwise indicated, steel sheet gutters upto 1.25 mm thick shall be stiffened with stays
at spacing not exceeding 40 cm. Stays of tubular pattern shall be soldered in position in the
gutter.

Jointing :

Al joints shall be lapped and soldered for at least 40 mm, in the direction of low; the jointing
faces shall be primed with solder to ensure running of the jointing metal. Soldering of the
resulting joint through the full girth of the gutter and to the full extent in the lap shall be
ensured. Jointing may be done by press folding (welting) of the jointing faces.

Fixing :

Gutters upto 100 mm size shall be fixed by screws inserted through alternate stays and those
above 100 mm size shall be fixed by screws inserted through every stay. The screws shall not
be less than 2.6 mm dia and not shorter than the nominal thickness of the gutter plus 25 mm.
screws shall not be hammered into place. Fixing of gutters by this method shall not be done
when facial board is less than 25 mm in thickness.

Signature of Contractor 190


Item No.-143: (For Schedule B)

Steel work welded in built up sections


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
, relevant drawings and as per the item description & as per instructions of Engineer in Charge.

The item shall be carried out as per item 117.

Item No.-144: (For Schedule B)

Interlocking Road paver block of M40 Grade


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D.
, relevant drawings and as per the item description & as per instructions of Engineer in Charge.

Materials and Workmanship :


The Paver blocks of approved make only shall be used.

The paver block shall be manufactured on the latest Hi-tech plant. Paver block shall be of
approved shape, size and colour or combination of them to attain desired aesthetics and
environment. The Paver block shall have ruborous top reflective surface & shall be highly
durable and shall not require CEMENT for fixing (laying) and shall be easy for laying and it can
reusable. The compressive Strength of paver blocks shall be 400 kg/cm2 and above.

The surface of the paver blocks shall be slightly rough textured and the edges shall be tapered
so as to give good skid resisting properties.

The minimum thickness of the paver block shall be 80 mm .

Installation :

Installation of paving blocks shall be so simple that it can be removed and relaid at a later date
if repair is necessary or to accommodate service lines without the usual ugly scar as is now
common with concrete or asphalt monolithic surfacing.

Preparing Base :

Special care shall be taken in preparing the base to assure a permanent installation. The depth
of the base will be determined by the load factor and the condition of soil.

Base :

The base should be a sharp sand or stone dust.

The base of sand shall be total 25 mm thick and shall be well compacted with a vibrating type
compactor. This should consist of a good Grade Sand. This should then be covered with 50 mm
of sharp sand or stone dust screeded level but not compacted.

Levelling the Base :

Signature of Contractor 191


This is an important step in installation to achieve a good level job when finished. Make sure
the base is levelled properly. Generally the most popular method of levelling is with a screed
which is usually a long 2” x 6” board. It is very important that the board is straight, not warped
or twisted. Although for larger commercial jobs screeding bars or pipes may be used. A frame is
required to maintain the base. The levelling of this frame will indicate the level of the area.

Placing Paving Blocks :

Blocks should be placed in the desired pattern close together. The spaces between blocks
should not exceed ¼ “ (3 mm). The spacing should be consistent. This will help maintain a
uniform pattern. When laying each row the installer should stand on the previously laid stones.
Cutting of stones where necessary can be done with a splitter chisel or masonry saw as
required.

Completing the Job :

The paver blocks should then be tamped down and leveled with a vibrating plate compactor.
This will bring them to their true grade as well as level the blocks. Sand will be forced into
spaces to make blocks firm and free of movement. Finish the job by sweeping dry fine sand into
the joints. The edges /ends of the pavement shall be finished with 1:2:4 concrete. The rate
shall be inclusive of concrete.

Mode of Measurement and Payment :

The rate includes all materials, labour, tools, plants in satisfactory completion of work as
specified above.

The rate shall be for unit of one sq.mt. for actual work done.

Supplying planting of shrubs of approved veriety in pits


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D/
GWSSB. , relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.
General Specification for landscaping and horticultural work

1. All the plants must be healthy, well established in either poly bag or earthen pots and
of proper size as mentioned in specification or in schedule.
2. Contractor shall have to supply the plants variety wise with true name of
varieties.
3. All tall plants must be staked properly to keep the plants straight and erect even
after the plantation is carried out.
4. Plants having exposed root system shall be rejected(except lawn grass)
5. All the plants including ground covers must be well established in poly bag of about
10-15cm dia.
6. Contractor shall have to replace the plants of same variety and size if there is any
casualty or damage without any extra payment.
7. Mostly, all the plantation is to be carried out after providing and filling the new

Signature of Contractor 192


fertile agriculture soil (70%) and manure (30%) after necessary excavation as
mentioned in specification or as in Schedule.
8. Contractor shall have to make his own arrangement of watering and electric
power supply for irrigating the plantation in the whole campus at his own cost upto
the contract period + maintenance period.
9. The excavated material shall be collected at desired site and spread in required
contour by contractor.
10. Watering shall be carried out immediately after plantation is done.
11. Pre-planting watering should be carried out after refilling pits with soils and
manure.
12. Antitermite treatment with Chloropyrophos insecticide should be carried out at the
rate of 10 ml/1 lit. of water/smt of approved ISI Mark.
13. The contractor shall have to substitute any plant and shall execute planting method
on site as directed by EIC.
14. Minimum two trained gardener and eight workers shall be employed during the
maintenance job or otherwise as per the tender conditions.
15. The height of all the plants shall be measured form the top rim of the
container(plastic bag or earthen pot)

Development of trees

Rates to be quoted for development of trees for planting done outside the Lawn areas.
a. Excavation where required of pits size to be 600mm deep as per locations marked
on the drawings/as per instructions given at the site by the EIC.
The size of the pit shall be checked with standard wooden box of the same size.
b. Spreading the excavated soil on the ground around the pits. Filling the good quality,
ordering the garden soil and good quality well rotten soil farm yard manure 1/3
quantity of pit volume. Soil and F.Y. M is to be supplied by the contractor.
c. F.Y.M to be mixed well in the top 450mm of the soil layer only.
d. Soil, manure filling in pits to the well watered, in order to settle the soil and soil and
remove the air pockets. Levels of the pits shall be made up by adding red / fertile soil and
F.Y. mixture.
e. Treating each pits against white ants with approved insecticide. Insecticide to be
supplied by the Contractor.
f. Planting of Plant-materials, such as trees, Shrub, creepers, etc.
g. Development period for trees/shrubs/creepers shall be a period of six months, or till
satisfactory development of sapling (whichever is later) from the date of planting.
This shall include timely watering, pruning, stalking, wedding, mulching and
spraying of weedicides, fungicides, applying of fertilizers as and when required. If the
plant does not survive, the same to be repeated immediately, free of all charges
with the plant of same species and approximately of the same height by the
Landscape Contractor. Fertilizer pesticides/ fungicides shall be provided by the
Client.
h. Measurement & rate shall be paid on number basis.

Providing Retro reflactive board with metal sheet & angle supports at frame with
lettering of approved size incl. fixing / hanging the same at site shown by E.I.C.
rate incl. all charges.

Signature of Contractor 193


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D/
GWSSB. , relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

The scope of work shall include providing Retro reflactive board with metal sheet & angle
supports at frame with lettering of approved size incl. fixing / hanging the same at site shown
by E.I.C. rate incl. all charges.

Mode of measurement and payment :

The rate shall include all materials, tools, plants, labour involved in satisfactory completion of
work as prescribed as above.

The rate shall be paid sqm basis as per actual work done.

Measurement shall be in sqm of actual work done.

Providing Light board with G.I. sheet back & front of flax banner
In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D/
GWSSB. , relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.
The scope of work shall include providing Light board with G.I. sheet back & front of flax
banner with lettering & light arrangement inside banner box incl. fixing / hanging the same at
site shown by E.I.C.rate incl. all charges.

Mode of measurement and payment :

The rate shall include all materials, tools, plants, labour involved in satisfactory completion of
work as prescribed as above.

The rate shall be paid sqm basis as per actual work done.

Measurement shall be in sqm of actual work done.

P.V.C door with P.V.C frame

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D/
GWSSB. , relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

The scope of work shall include providing and fixing P.V.C door with P.V.C frame, the frame
should have made from 310 section (3" X 1") and the shutter frame manufactured from 310 no.
sintex section (3" X 1"). The pannel of the door should be made from 101 no. sintex section
(20mm X 250m)

Mode of measurement and payment :

Signature of Contractor 194


The rate shall include all materials, tools, plants, labour involved in satisfactory completion of
work as prescribed as above.

The rate shall be paid sqm basis as per actual work done.

Measurement shall be in sqm of actual work done.

Rrubbles including hand packing In general the work shall be carried out as per the
standard specifications of P.W.D. / C.P.W.D/ GWSSB. , relevant drawings and as per the
instructions of Engineer in Charge. Work shall be carried out as per item description.

1. The rubble stones shall be black in colour, shall be hard. tough, sound durable and of dose
texture, free from cracks and it shall be obtained from the approved quarries.

2. The rubble obtained from the top surface of the quarry is soft one and hence such soft
variety shall not be accepted. All unsound weathered or disintegrated stones obtained from the
upper portion of the quarry shall be rejected.

3. The quarry shall be well protected shall be dug by removing all the katcha and weathered
stuff till approved quality of materials is available.

4. The length and breadth shall not exceed 1/f (1.2) times the thickness of the stones.

5. The rubble stacks shall be made on a fairly level ground and stacks shall be so made that
rubble stones are stacked as close as possible so as to leave no excessive voids and no hollows
are left out.

6. The tendency to prepare the stacks by keeping excessive voids or keeping hollow places shall
not be tolerated.

7. The stacks shall be uniform in length and breadth and top portion shall be in level so that
height at any point is uniform. .

8. All the stacks shall be of standard dimensions which shall be prescribed by the Executive
Engineer deduction for voids shall not be made.

9. The rubble shall be got approved by the Executive Engineer prior to collector on site or
otherwise it is liable to rejection for which no claim shall be entertained.

10. The contractor shall maintain alt stacks in regular and proper sizes till the whole material is
collected. Measured and finally accepted by the department. 15 percent spauts will be allowed
for filling in interstices.

11. The rubble shall be stacked in quantities as per hectometre wise requirement as directed by
the Executive Engineer or his agent.

12. Measurement shall be given only when the full quantity of a half kilometer is stacked
measurements shall be recorded and paid only ones in a hectometre and no piecemeal
measurements shall be recorded and paid.

Signature of Contractor 195


13; Stacks shall be made as per actual requirements and any material in excess shall have to be
transported by the contractor at the places directed by the Executive Engineer at the risk and
cost of the contractor.

Stone shall be hard, sound, free from cracks, decay and weathering and shall be freshly
quarried from an approved quarry. Stone with round surface shall not be used. The length of
stone shall not exceed three times its height and the breadth on base shall not be greater than
three fourth of the thickness of wall nor less than 15 cm. The rubble shall be stacked in chatters
manner on fairly leveled ground as and where directed as per the instruction of the Engineer-in-
charge. 16% for voids shall be .deducted from gross measured quantity.

The rate includes all labours, materials, tools and equipments, dumping the rubble and
spreading in required thickness as per drawing and as directed by EIC. and all other incidental
expenses occurred. The payment shall be made on cmt. Basis.

Supplying & spreading of crushed stone aggregates.


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D/
GWSSB. , relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1. The stone metal shall be obtained from quarries approved by the Executive Engineer
prior to collections. The metal shall be of approved quality with all leads and lift. The
metal shall be obtained from hard tough, sound durable, stone of close texture as is
locally available and reasonably free from decay and weathering. Pieces of the stone
shall be angular and roughly cubical in shape and round, elongated or flaky materials
shall be allowed. The size of metal shall be 40 mm to 63 mm and shall be hand
broken. All unsound weathered or disintegrated stone obtained from the upper
surface layer of the quarry or other layers of boulders shall be rejected.

2. The samples of metal collected from approved quarries shall be got tested at
Government recognized laboratory as may be directed to the contractor at his own
cost. The test result shall conform to the standard requirements laid down for metal
to be used for W.B.M. work.

3. The physical requirement for standard size metal shall conform to the test results
indicated in the Table below :

Type of Const. Test Test Method Requirement

Base (a) Los Angeles IS 2386 Part IV 50% (Maximum)

Abrasion value

Aggregate Impact IS 2386 Part IV 40% (Maximum)


value

(b) Flakiness Index IS 5640 15% (Maximum)

IS 2386 Part-I

Signature of Contractor 196


Frequency of test shall be as per Ministry of Surface Transport specifications.

4. The grading requirements of the metal to be used for W.B.M. shall be as under :-

Sr. No Size range Sieve Designation Percentage by weight


passing through the sieve

4
1 2 3

1. 40 mm to 75 mm 100-100
63 mm
63 mm 90-100

50 mm 60-80

40 mm 0-15

25 mm 0-5

5. Wherever any doubt exists as to whether the above requirements are satisfied,
in whole or any part of the collection, metal shall be got screened by the
contractor at his own cost, if so ordered by Engineer-in-charge.

6. Stacking shall be filling in the standard steel boxes of 2 m x 1.5 m x 0.5 m size
which shall be supplied by the Department if available on rent. Otherwise
contractor shall make his own arrangements. No deduction for voids shall be
made from the gross measurements. Where any doubt exists as to whether the
quantity of stacks of metal in any hectometer is not confirming with the cubical
content of the standard pharas (2m x 1.5m x 0.5m) shall be got corrected by the
contractor if so ordered by the Engineer-in-charge for which no extra payment
shall be claimed by the contractor. If the quantity of metal in any stack in a
particular Hectometer shall be paid on the basis of the quantity so found.
Regular stacks shall be done by the contractor on a fairly level ground. Stacking
of the metal shall be done in a manner as directed by the Engineer-in-charge.
Collection of metal shall be completed in two hectometer wise as per the final
requirement and measurement shall be recorded two hectometer-wise. Until the
quantity of metal as per final requirement is not collected in any two consecutive
HM and std. boxes are not filled in completely in two hectometers,
measurements shall not be recorded and payments shall not be done.

7. For road work complete staking of metal as per requirement shall be carried out
in 2 km length before spreading. The metal stacks shall be measured and
recorded and got cross checked by other Deputy Executive Engineer as per rules
before spreading. The collection shall always, commence at one end of the km
and be carried continuously towards the other end unless the Engineer-in-charge
shall direct otherwise.

8. The payment shall be on cubic meter basis without deduction for voids. The
contractor shall maintain all stacks in regular and proper size till the whole
materials shall not measured and finally accepted by the Department. The

Signature of Contractor 197


spreading of materials shall not be allowed till the materials are fully stacked and
completed kilometer wise.
The rate includes cost of collection, conveyance to the site with all lead and lift and filling the
boxes including all labour, tools, equipment and other incidental expenses. The rates quoted
are inclusive of all such tools, duties, fees, royalties, taxes etc.

The size of metal for W.B.M. shall be 40mm. to 63mm. wherein tolerance limit for oversize
shall be 10 percent and that for lower size should be upto 15 percent and below 25 mm it
shall be upto 5 percent.

10. Standard for acceptance at reduced rate and rejection shall be as under :-
(a) Retained on 63 mm. square mesh sieve:
Not more than 30%
(b) Retained on 75 mm. square mesh sieve :

Nothing will be retained & 100% metal shall be pass through the sieve. For the oversize
metal, payment at reduced under :

(A) 90% of accepted tender rates for the metal retained between 10% and 20% square
mesh sieve of 63
mm. gauge.

(B) 75% of accepted tender rates for the metal retained more than 20% and upto 30% on
square mesh sieve of 63 gauge.

If more than 30% of metal is retained on specified sieve, (i.e. 63 mm. square sieve) the
stack shall be rejected. Also if any stone aggregate retained on 75 mm. sieve the stack
shall be rejected.
The quality for which reduced rate will be applicable is the quantity retained on the
above mentioned square mesh sieve and not the whole quantity. For example in a stack
of 1.5 cum. Metal if 18% is retained on square mesh sieve of the prescribed size (i.e.
63mm) the reduced rate of 90% will be applicable to 0.27 cu.m. only and the balance
quantity size shall be paid for the accepted rates for standard size metal.

Before any secured advance for metal is paid to the contractor, the metal shall have to be
tested for its quality in the laboratory. Contractor‟s request for such secured advance will be
considered only after test results of metals are received and results are satisfactory.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D/
GWSSB. , relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1. Metal shall not be spread without permission of the Engineer- in –charge. Metal should
be spread under careful supervision by trained coolies. Contractor shall see that uniform
spreading as per collection of metal is done. The contractor shall spread the metal fully
from the stacks without keeping any balance unless directed by the Engineer- in –
charge to keep some stack in balance for making good unevenness or depressions
during rolling works. To ensure that the material is spread to the required thickness, the

Signature of Contractor 198


road surface shall be marked out in to length over which the contents of heaps are to be
spread. The bounds of earth murrum (one on either side) shall be laid with a distance
between them equal to the width of road to be metaled and shall be enough to prevent
the loose metal from spreading during consolidation as well as retain water used for
consolidation . Payment for bunds will be made in the respective item.
2. The metal (including old metal) shall be screened and rubbish, dust, grass shall
be removed and spread evenly on the prepared surface in grade and camber by
using camber board etc. So as to ensure that the surface is true to camber and
grade. At least two camber by using camber boards shall be an use at site./ The surface
shall be checked at every 50 ft. by means of complete while the correctness of the
camber in between shall be tested by string and corrected as required. Between straight
lengths and the curves in camber of roads to super elevation shall be made very
gradually as may be directed by the Engineer- in – charge.

3. The spreading of metal shall proceed only 200 mt. (max) advance of the rolling
operations. The collection and spreading of the metal shall not be carried out in one and
the same kilometer.

4. At the time of rolling all surface irregularities, hollows, depressions, humps etc. shall be
straight. The spreading of metal in required layer shall be done by the contractor. The
rate for this item shall be paid on cmt. Basis and includes all the above operations with
all lead and lift except consolidation.

Supplying & spreading of murrum for WBM road in required gradiant including
rolling with power roller.

In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D/
GWSSB. , relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

1. Material for the purpose shall be of approved quality. Any material which is found
inferior shall be rejected and the contractor shall remove such rejected material from
the site at his own cost. The material shall be collected from quarries approved by the
Engineer. The material shall be granular and gritty.

2. The material shall be got approved by the Engineer prior to collection on site. It shall be
free from all rubbish, dust and any organic materials as well as clods of black cotton
soils. Materials shall not be allowed to be collected from within the road boundary.
Material to be used as crust and for side shoulders shall be as per C.B.R. report and that
to be used bindage in W.B.M. road construction shall have P.I. value of less than 6 as
determined in accordance with IS 2720 (Part – v). The material to be used should be
got tested prior to its use in road construction. Testing charges shall be borne by the
contractor.

3. River or nala or seasand required for the work shall be clear, sound, properly, graded,
free from organic materials, silt ,clay etc. and shall be got approved by the Engineer - in
– charge The sand shall be obtained and brought from the source approved by the
Engineer- in- charge. The sand shall be well graded.

Signature of Contractor 199


4. Stacking shall be done by filling in the standard steel boxes of 2 m * 1.5 m * 0.5 m size
which shall be supplied by the Department if available on rent. Otherwise contractor
shall make his own arrangement. No deduction for voids shall be made from the grade
measurements. Where any doubt exists as to whether the quantity of stacks of murrum
in an hectometre is not confirming with the cubic content of the standard pharas (2 *
1.5 * 0.5 M) the same shall be got corrected by the contractor if so ordered by the
Engineer – in – charge for which no extra payment shall be Claimed by the contractor. If
the quantity of murrum in any stack in a particular hectometre is found to be less than
the standard measurements viz., 1.5 cmt. The entire collection in the hectometre shall
be paid on the basis of the quantity so found. Regular stacks shall be done by the
contractor on a fairly level ground. Stacking of the murrum shall be done in a manner as
directed by the Engineer – in – charge

5. For road work complete stacking of murrum as per requirement shall be carried out in 2
K. M. length before spreading. The collection shall always, be commenced at one end of
the K.M. and be carried continuously toward the other end unless the Engineer – in –
charge shall direct otherwise.

6. The payment shall be made on cubic metre basis without deduction for voids. The
contractor shall maintain all stacks in regular and proper size till the whole materials are
collected, measured and finally accepted by the department. The spreading of materials
shall not be allowed till the materials are fully stacked and completed kilometer wise.

7. The rate includes cost of collection, conveyance to the site with all lead and lift and
filling the boxes includes all labour, tools, equipment and other incidental expenses.
8. The rate quoted are inclusive of all shall such tools, duties, fees, royalties, taxes etc.

Spreading of material shall be stared after the full supply in a particular K.M. is collected,
measured and recorded in the measurement books. Permission of the Engineer- in – charge
shall be obtained before spreading. It shall be seen that the formation is dressed to the
required camber and grade. If the murrum is to be spread over the metaled surface then the
spreading shall be uniform and as its has to act as binding surface, it shall be used for filling the
interstices of metal and forming a smooth running surface as far as possible. Murrum blindage
shall be specified as blindage shall be spread evenly with a twisting motion of the baskets. No
more Murrum shall be used then specified as blindage. The rate is for gross measurements and
no deduction of voids shall be made. I, the murrum is to be spread over earthen embankment
as a sub- base or for side shoulders or as blindage, it shall be spread in a manner as directed
by the Engineer- in- charge and as per required width and thickness. The contractor shall make
good all unevenness, depression, projection etc. during consolidation work. Rate of this item
includes all these operation except consolidation. The payment shall be made on cum. basis.

Water bound macadam (Except laterite and kankar)


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D/
GWSSB. , relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.
1. Immediately following the spreading of the coarse aggregates rolling shall be with three
wheeled power rollers of 8 to 10 tonne capacity or tandem roller or equivalent vibratory roller.
The weight of the roller shall depend upon the type of the aggregate and be indicated by
Engineer – in – charge.

Signature of Contractor 200


2. Except on super elevated portions where the rolling shall proceed from inner edge to
outer, roling shall begin from the edges gradually progressing towards the centre. First the
edge/ edges shall be compacted with roller running forward and backward. The roller shall then
move inwards parallel to center line of the road in successive passes uniformly lapping
preceding tracks by at least one half the width.
3. Rolling shall continue uoroughly keyed and the creeping of the aggregate ahead of the
roller is no longer visible. During rolling slight sprinkling of water may be done, if necessary.
Rolling shall not be done when the sub-grade is soft or yielding or when it causes a wave like
motion in the sub- grade or sub- base course.
4. The rolled surface shall be checked transversely and longitudinal and any irregularities
corrected by loosening the surface, adding or removing necessary amounts of aggregate and
rerolling until, the entire surface conforms to desired camber and grade. In no case use of
screening be permitted to make up depression.

5. The blindage material where it is required to be used shall be applied successively in two
or more thin layers at a slow and uniform rate. After each application, the surface shall be
copiously sprinkled with water, the resulting slurry swept in with hand brooms or mechanical
brooms to fill the voids properly and rolled, during which water shall be applied to the wheels of
the rollers if necessary to wash down the binding material sticking to them. These operations
shall continue until the resulting slurry after filling of voids, forms a wave ahead of the moving
roller.
6. After the final compaction of water bound macadam course the road shall be allowed to
dry overnight. Next morning hungry spots shall be filled with screenings of binding materials as
directed, lightly sprinkled with water if necessary and rolled. No traffic shall be allowed on the
road until the macadam has set. The Engineer –in – charge shall have the discretion to stop
hauling traffic from using the complete water bound macadam course if in his opinion if would
cause damage to the surface.
7. Payment will be made on Smt. basis of the finished work and shall include cost of
watering, rent of machinery cost fuel, wages of drivers and cleaners and murrum bund etc.

Multipurpose storage cabinet with 4 shelves making 5 compartment.


In general the work shall be carried out as per the standard specifications of P.W.D. / C.P.W.D/
GWSSB. , relevant drawings and as per the instructions of Engineer in Charge. Work shall be
carried out as per item description.

The scope of work shall include providing & supplying Multipurpose storage cabinet with 4
shelves making 5 compartment. All steel parts of the cabinet will be (20/22 swg.) CRCA IS 513
„D‟ grade 10 tanks antirust treated Standard Powder Coating in plant. Having locking
arrangement with approved colour of size 915 x 485 x 1980 mm

Mode of measurement and payment :

The rate shall include all materials, tools, plants, labour involved in satisfactory completion of
work as prescribed as above.

The rate shall be paid sqm basis as per actual work done.

Measurement shall be in sqm of actual work done.

Signature of Contractor 201


SPECIFICATIONS FOR ELECTRICAL WORKS IN GOVERNMENT BUILDING SUBJECT
TO THE GENERAL CONDITION OF CONTRACT IN FORCE

GENERAL

1. Wiring Rules:
The installation generally shall be carried out. in conformity with relevant
Indian Standard Specifications and code of practices prevalent, Indian Electricity
Rules 1956 and Indian Electricity Act, 1910 as amended from time to time.

2. Definition:

The definition of terms shall be in accordance with Indian Standard code of Practice
for Electrical wiring Installation IS-732-1982 except for the definition of point
in case of Internal Electrical Installation. For definition of point wiring and
measurement of Electrical works IS-5908-1970 shall be referred to.

3. Voltage and Frequency of Supply:

All current consuming devices shall be suitable for frequency of 50 C/s and system
of voltage meant for unless otherwise specified.

4. Layout of wiring and its description:

(i) The wiring shall be carried out as per Schedule "power" wiring must be in
screwed conduit and shall be kept separate and distinct from lighting wiring.
All wiring must be done on the distribution system with main and branch
distribution boards at convenient centers and without isolated fuses. All
conductors shall be run as far as possible along the walls and ceiling as to be
easily accessible and capable of being thoroughly inspected. The balancing of
circuits will be arranged before hand by the Ex. Engineer Electrical Division.

(ii) With in one month of the taking over the installation, the contractor shall
supply to the Ex. Engineer, Elect. Division a complete set of wiring diagrams
of the same on drawings to be supplied when available by the Executive
Engineer, Electrical Division, and to the satisfaction of the Ex. Engineer,
Elect. Dn, and these wiring plans shall be "Drawings" within the meaning of
the term as used in the General Conditions of contract.

5. Conductors:

All conductors unless otherwise specified shall not be less than 1.5 Sq. mm for
point wiring and 2.5 Sq. mm for mains. Conductors for power and lighting
circuits shall be of adequate size to carry the designed circuit load without
Signature of Contractor 202
exceeding the permissible thermal limits for the installation, and such sizes
will be stipulated in specifications and or drawings.

6. Cables:

6.1 All cables shall conform to relevant Indian Standards

6.2 Conductors of all cables except the flexible cable shall be of aluminium. The
smallest aluminimum conductors for the final circuit shall have nominal cross sectional
area of not less than 1.5 Sq. mm. The minimum size of the aluminium conductors for
power wiring shall be 4 Sq. mm

6.3.1 Conductors of flexible cables shall be of copper. The minimum cross


sectional area of such a cables shall be lf.0193 mm. The flexible cable shall have
uniform and adequate insulation.

6.3.2 Unless the flexible cables and conductors are protected by armour or
tough rubber or PVC Sheath, these shall not be used in workshops and other places
where they are liable to mechanical damage.

6.3.3 Core flexible, cables shall be used for connecting single phase
Appliances for phase, neutral & earth- connections.
7. Fall of Potential:

The cross sectional area of all conductors inside buildings shall be so proportioned to
their lengths that the drop
in voltage between main fuses and the farthest point or any lamp shall not exceed
three percent of the voltage of the consumer's with all the consuming devices in use.

7.1 If the CABLE SIZE is increased to avoid the voltage drop in circuit current rating of
the cable shall be more than that for which the circuit is designed. In each circuit or
sub circuit every cable shall have a current rating not less than that of the fuse
which protects the circuit or sub circuit respectively for current higher than the
full load current.

8. Ratings of lamps and fans socket out lets: Points and exhaust fans:

8.1 Incandescent lamps installed in residential and non- residential buildings shall be
rated at 60 watts & 100 watts respectively.

8.2 Table fans and ceiling fans shall be rated at 60 watts, exhaust fan shall be rated
according to their capacity.

Signature of Contractor 203


8.3 5 Amp. socket outlet points and 15 Amp. sockets outlet points shall be
rated at 100 watts and 1000 watts respectively for the purpose of load assessment
unless actual values of the load are known or specified.

9. Tests:

9.1 Before the installation is commissioned following tests shall be carried out.

(1) Insulation Resistance test.

(2) Polarity Tests of Switches

(3) Earth continuity tests

(4) Earth electrodes Resistance test.

9.2.1.1 The insulation resistance shall be measured between earth and the whole
system of conductors or any section- there of with all fuses in place and all
switches closed, and except in earthed concentric wiring all lamps in position or
both poles of the installation otherwise electrically connected together- a direct
current pressure of not less than twice the working pressure provided that it
need not exceed. 500 volts for medium voltage circuits where the supply is
derived from the three wire D.C. or a poly phase A.C. System, the neutral pole of
which is connected to earth either direct or through added resistance, the working
pressure shall be deemed to be that which is maintained between the phase
conductor and the neutral.

9.2.1.2 The insulation resistance shall also be measured between all conductors to one
pole or phase conductor of the supply and all the conductors connected to the neutral or
to the order pole or phase conductors of the supply with
all lamps in position and switches in 'OFF' position and its value shall be not less than in
that specified in Sub- Clause 9.2.1.3.

9.2.1.3 The insulation resistance in Megohms measured as above shall not be less
than 50 Megohms divided by the number of outlets or when PVC insulated cables are
used for wiring 12.5 megohms divided by number of outlets.

9.2.1.4 Where a whole installation is being tested, a lower value than that given by the
formula, subject to a minimum of 1 megohm is acceptable.

9.2.1.5 A preliminary and similar test may be made before lamps, etc. are
installed and in this event the insulation resistance to earth should be not less
than 100 megohms divided by the number of outlets or when PVC insulated
cables are used for wiring 25 megohms divided by number of outlets.
Signature of Contractor 204
9.2.1.6 The term "Outlet" includes every switch except that a switch combined with a
socket outlet, appliance or lighting fitting is regarded as one outlet.

9.2.1.7 Control rheostat heating and power appliance and electric sign may, if
required, be disconnected from the circuit during the test, but in that event the
insulation resistance between the case or frame work, and all live parts of each
rheostat, appliance and sign, shall be not less than that specified in the
relevant Indian Standard Specification or where there is no such specification shall
be not less than half a megohm

9.2.2 Polarity Test:

9.2.2.1 In a two wire installation a test shall be made to verify that all switches in every
circuit have been fitted in the same conductor through out & such conductor shall be
labeled or marked for connection to the phase conductor
or to the non-earthed conductor of the supply.

9.2.2.2 In a three wire or a four wire installation a test shall be made to verify that
every non-linked single pole switch is fitted in a conductor which is labeled or marked for
connection to one of the phase conductor of the supply.

9.2.2.3 The installation shall be connected to the supply for testing. The terminals of all
switches shall be tested by a test lamp one lead of which is connected to the earth.
Glowing of test lamp to its full brilliance, when the switch is in 'on' position irrespective
of appliance in position or not shall indicate that the switch is connected to the
right polarity.

9.2.3 Earth Continuity Test:

The earth continuity conductor including metal conduits and metallic envelops
of cables in all cases shall be tested for electric continuity and the electrical
resistance of the same along with the earthing lead but excluding any added
resistance or earth leakage circuit breaker measured from the connection with the
earth electrode to any point in the earth continuity conductor in the completed
installation shall not exceed one ohm.

9.2.3.1 Earth Electrode Resistance Test:

Earth electrode Resistance test may be carried out by Megger Earth Testers
containing a direct reading ohm- meter, a hand driven generator and auxiliary
electrodes.

9.3 On completion of an electric installation (addition and alteration) a certificate


shall be furnished by the contractor countersigned by the certified Supervisor under
whose direction supervision the installation was carried out. This certificate shall be in
the prescribed form as given in Appendix-'B' in addition to the test certificate required
by Local Electrical Supply Authorities.

Signature of Contractor 205


10. Joint and looping back:

Unless with the sanction of Ex. Engineer Electrical Divisions all joints in conductor
shall be means of approved mechanical connectors in suitable and approved junction
boxes but looping back system shall be preferable. IN wiring unless otherwise
specified Phase and live conduct shall be looped at the switch box where an
neutral conductor can be looped from light, fan or socket. In non-residential
buildings, neutral and earth continuity wire shall be brought to each of the switch
boards and terminated therein with suitable connectors in Switch boards should be of
adequate size to accommodate at least one number of 5 Amps, socket outlet and
control switch in future.

11. Switches:

Main Switchgears, Switch Board and their location:


11.1 All main switches (other than those of iron clad pattern) carrying current of 10
Amp. and above shall be fitted for back connections and shall be suitably protected.

11.2 All switches and circuit breakers shall be constructed in accordance


with the I.S. 4237-1967. General requirement for switchgear and control gear for
voltage not exceeding 1000 Volts and other relevant I.S. provided also that spring
shall be either of phosphor bronze or if steel shall be copper or Nickel plated and
that handle shall be so fastened that they do not tend to unscrew or become loose.

11.3 All main switches shall be either of metal clad enclosed pattern or of any insulated
enclosed pattern which shall be fixed at close proximity to the point of entry of supply.

11.4 Switch boards shall not be erected above gas, stoves, or sinks or within 2.5 m of
any washing unit in the washing rooms of laundries or in the bath rooms, lavatories,
toilets or kitchens.

11.5 Switch boards, if unavoidably fixed in places likely to be exposed to


weather, to drip, or to abnormal moist temperature the outlet casing shall be
weather proof and shall be provided with glands or bushing of adopted to receive
screwed conduit according to the manner in which cables are run. PVC and double
flanged bushes shall be fitted in the holes of the switches for entry and exit of wires.

11.6 A switch board shall not be installed so that its bottom is within 1.25 m above
the floor unless the front of the switch board is completely enclosed by a door
or the switch board is located in a position to which only authorized persons
have access.

11.7 Switch boards shall be recessed in the wall if so specified in the schedule of
work or in the special specification. The front shall be fitted with hinged panel of other
suitable material such as bakelite in wood frame with locking arrangement, the outer
surface of door being flush with the walls. Ample room shall be provided at the back
for connections and at the front between the switchgear mountings and the door.

Signature of Contractor 206


11.8 Equipments which are on the front of a switch board shall be so arranged that
inadvertently personal contact with live parts is unlikely during the manipulation of
switchgears, changing of fuses or like operations.

11.9 No holes other than the holes by means of which the panel is fixed shall be drilled
closer than 1.3 cms. from any edge of the panel.

11.10 The various live parts, unless they are effectively screened by substantial
barriers of non-hydroscopic, non- inflammable insulating material, shall be so
spaced that space shall not be maintained between such parts and earth.

11.11 The arrangement of gear shall be such that they shall be readily
accessible and their connections to all instruments and apparatus shall also be
traceable.

11.12 In every case in which switches and fuses are fitted on the same pole, these fuses
shall be so arranged that the fuses are not alive when their respective switches are in
the off position.

11.13 No fuses other than fuses in instrument circuit shall be fixed on the back of or
behind a switch board panel or frame.

11.14 All the metal switchgears and switch boards shall be painted, prior to erection
with one coat of antirust primer. After erection they shall be painted with two coats
of approved enamel or aluminium paint as required on all sides wherever accessible.

11.15 All switch boards connected to medium voltage and above shall be
provided with 'Danger Notice Plate' conforming to relevant Indian Standards.

12. Control at Point of Commencement of Supply:

12.1 There shall be a linked main switchgear with fuse on each live
conductor of the supply mains at the point of entry. The wiring through out the
installation shall be such that there is no break in the neutral wire except in the form
of a linked switchgear. The neutral shall also be distinctly marked. In this
connection Rule 32(2) of the Indian Electricity Rules 1966 (See Appendix 'A') shall
also be referred.

12.2 The main switchgear shall be situated as near as practicable to be termination of


service line and shall be easily accessible without the use of any external aid.

12.3 On the main switchgear, where the conductor of a two wire system or an
earthel neutral conductor of a multi-wire system or a conductor which is to be
connected thereto, an indication of a permanent nature shall be provided to identify
the earther neutral conductor. In this connection Rule 32(1) of Indian
Electricity Rules 1956 (see appendix 'A') shall be referred.

13.0 Switch Board & Distribution Boards:

Signature of Contractor 207


Metal clad switch gear shall preferably be mounted on any of the following types of
Board.

13.1 Hinged type Metal Boards:

These shall consist of a box made of sheet metal not less than 2 mm thick and shall
be provided with a hinged cover to enable the board to swing open for examination of
the wiring at the back. The joints shall be welded. A teak wood board, thoroughly
protected both inside and outside with good insulating varnish conforming to IS :
347-1952 specification for varnish shellac, for General purpose, and of not less than
6.5 mm thickness, shall be provided at the back for attachment of incoming and
outgoing cables. There shall be a clear distance of not less than 2.9 cm between the
teak wood board and the cover, the distance being increased for larger boards in
order that on closing of the cover, the insulation of the cables is not subjected to
damage and no short length of cables
is subjected to excessive twisting or bending in any case. The board shall be securely
fixed to the wall by means
of rag bolts, plugs or wooden Gutties and shall be provided with a locking
arrangement and an earthing stud. All wires passing through the metal board shall be
bunched. Alternatively, hinged type metal boards shall be made of sheet covering
mounted on channel or angle iron frame.

Note : Such type of boards are particularly suitable for small switch-boards
for mounting metal-clad switchgear connected to supply at low voltages.

13.2 Fixed type Metal Boards:

These shall consist of an angle or channel of iron frame fixed on the wall or on floor
and supported on the wall at the top if necessary. There shall be a clear
distance of one meter in front of the switch board. If there are attachments
of base connections at the back of the switch board Rules 51(1) (c) of Indian
Electricity Rules', 1956 shall apply.

Note : Such type of boards are particularly suitable for large switchboard for
mounting large number or switchgears or higher capacity metal clad switchgears or
both.

13.3 Teakwood Boards:

For small installations connected to a Single phase 230 volts supply teak wood boards
may be caused as main boards or sub-board. These shall be of seasoned teak or
other durable wood with solid back impregnated with varnish of approved quality with
all joints dovetailed.

13.4 In large size medium voltage installations, before proceeding with the actual
construction of the boards, a proper drawing showing the detailed dimensions and
design including the disposition of the mountings, which shall be symmetrically and
neatly arranged for arriving at the overall dimensions, shall be prepared and '
approved by the engineer-in-charge.

Signature of Contractor 208


13.5 Recessing of Boards:

Where so specified, the switch boards shall be recessed in the wall. The front shall be
fitted with a hinged panel
of teak wood or other suitable material, such as bakelite, or with unbreakable glass
doors in teak -wood frame with locking arrangement, the other surface off the
doors being flush with the walls. Ample room shall be provided at the back for
connection and at the front between the switchgear mountings.
13.6 Arrangement of Apparatus:
a) Equipment which is on the front of a switch board shall be so arranged that
inadvertently personal contact with live parts is unlikely during the manipulation of
switches, changing of fuses or like operation.

b) No apparatus shall project beyond any edge of panel. No fuse body shall be
mounted within 2.5 cm. of any edge of the panel and no hole other than holes by
means of which the panel is fixed shall be drilled closer than 1.3 cms from any edge
of the panel.

c) The various live parts, unless they are effectively screened by substantial
barriers of non-hydroscopic, non- inflammable insulating material, shall be so
spaced that an arc cannot maintain between such parts and earth.

d) The arrangement of the gear shall be such that they shall be readily
accessible and their connections to all instruments and apparatus shall also be
easily traceable.

e) In every case in which switches and fuses are fitted on the: same pole, these
fuses shall be so arranged that the fuses are not alive when their respective switches
are in the 'OFF' position.

f) NO fuses other than fuses instrument circuit shall be fixed on the back of or
behind a switchboard panel or frame.

13.7 Marking of Apparatus:

a) Where a board is connected to voltage higher than 250 volts, all the apparatus
mounted on it shall be marked in the following colours to indicate the different poles or
phases to which the apparatus or its different terminals may have been connected.

Alternating Current Direct Current

Three-phase-red Three wire system-2


outer wires Yellow,& blue Postive red & negative blue.
Netural-black Neutral-black

Where fuse-wire three phase wiring is done, the neutral shall be in one colour
and the other three wires in
another colour.

Signature of Contractor 209


b) Where a board has more than one switch each such switch shall be marked to
indicate which section of the installation it controls.

c) All markings required under the rule shall be clear and permanent.

13.8 Main & Branch Distribution Board:

13.8.1 Main and branch distribution boards shall be of any type mentioned in
13.1

13.8.2 Main distribution board shall be provided with a switch or air circuit
breaker on each pole of each circuit, a fuse on the phase or live conductor and a link
on the neutral or earthed conductor of each circuit. The switches shall always be
linked.

13.8.3 Branch Distribution Board:

13.8.3.1 Branch distribution boards shall be provided with a fuse or a


miniature circuit breaker or both the adequate rating- setting chosen on the live
conductor of each circuit and the earthed neutral conductor shall be connected to a
common link and be capable of being disconnected individually for testing
purposes. At least one spare circuit of the same capacity shall be provided on each
branch distribution board.

13.8.3.2 In residential installations, lights and fans may be wired on a common


circuit such sub circuit shall not have more than total of ten points of lights, fans
and socket outlets. The load of such circuit shall be restricted to 800 watts. If a
separate fan circuit is provided, the number of fans in the circuit shall not exceed
ten. Power sub- circuits shall be designed according to the load but in no case shall
there be more than two outlets on each sub- circuits.

13.8.3.3 In Industrial and other similar installations requiring the use of group control
of switching operation, circuits, for socket outlets may be kept separate from fans and
lights. Normally fans and lights may be wired on a common circuit, however, if need is
felt separate circuits may be provided for the two. The road on any low voltage sub-
circuit shall not exceed 3000 Watts. In case of new installation, all circuits and sub-
circuits shall be designed by making provision of 20 per cent increase in load due to
any future modification. Power sub- circuits shall be designed according to the load
but in no case shall there be more than four outlets in each sub-circuits.

13.9 Installation of Distribution Boards:

13.9.1 The distribution fuse-boards shall be located as near as possible to the


centre of the load they are intended to control.

13.9.2 These shall be fixed on suitable stanchion or wall and shall be accessible
for replacement of fuses.
13.9.3 These shall be of either metal-clad type, or all insulated type. But, if
exposed to weather or damp situations, they shall be of the weather proof type and, if

Signature of Contractor 210


installed where exposed to explosive dust, vapor or gas, they shall be of flame proof
type.

13.9.4 Where two or more distribution fuse boards feed low voltage these
distribution boards shall be:

(1) Fixed not less than 2 m apart or,

(2) Arranged so that it is not possible to open two at a time, namely, they are
interlocked and the metal case is marked 'Danger 415 Volts', or

(3) Installed in a room or enclosure accessible to only authorized persons.

13.9.5 All distribution boards shall be marked 'Lighting', 'Power', as the case may
be, and also marked with the voltage and number of phases of the supply. Each shall
be provided with a circuit list giving details of each circuit which it controls and the
current rating of the circuit and size of fuse-element.

13.9.6 Triple pole distribution boards shall not be generally used for final circuit
distribution unless specific approval of Engineer in charge is obtained. In special cases
where use of Triple pole distribution boards are inevitable they shall be of H.R.C. fuse
type only.

13.10 Wiring and Distribution Board:

13.10.1 In wiring a branch board, total load of the consuming devices shall
be divided, as far as possible, evenly between the number of ways of the board
leaving the spare circuit for future extension.

13.10.2 All connections between pieces of apparatus or between apparatus and


terminals on a board shall be neatly arranged in a definite sequence following the
arrangement of the apparatus mounted thereon, avoiding unnecessary crossing.

13.10.3 Cables shall be connected to a terminal only by soldered or welded or


crimped lugs using suitable sleeve, lugs or ferrules unless the terminal is of such a
form that it is possible to securely clamp them without the cutting away of cable
strands.

13.10.4 All bare conductor shall be rigidly fixed in such a manner that a clearance
of at least 2.5 cms. is maintained between conductor of opposite polarity or
phase and between the conductors and any material other than insulating
material.

13.10.5 If required, a pilot lamp shall be fixed and connected through on independent
single-pole switch and fuse to the bus- bars of the board
13.10.6 In a hinged type board, the incoming and outgoing cables shall be fixed at
one or more points according to the number of cables on the back of the board
leaving suitable space in between cables, and shall also, if possible, be fixed at the
corresponding points on the switch board panel. The cables between these
points shall be arranged to form a 'U' or 'S' shaped loop which shall be of

Signature of Contractor 211


such length as to allow the switchboard panel to swing through an angle of not less
than 90°.

14.0 Capacity of Circuits:

14.1 Lights and fans may be issued on a common circuits and such a circuit shall not
have more than a total of ten points of lights, fan, and socket outlets, or a load of
800 watts whichever is less. The power circuits shall be designed with a maximum
of two outlets per circuits generally when load is not known or specified. In
non- residential buildings at important District centers however one outlet per
.circuit may be preferred. The circuit shall be designed based on the loading of the
circuit where not specified the load shall be taken as 1 KW per outlet. Where the load
is more than 1 KW it should be controlled by a isolator switch or miniature circuit
breaker.

15.0 Passing Through Walls and Floors:

15.1 Where conductors pass through walls one of the following methods shall be
employed. Care shall be taken to see that wires pass very freely through protective
pipe or box and that the wires pass through in a straight line without any twist or
cross in wires, on other ends of such holes.

(a) A teak wood box extending through the whole thickness of the wall shall be
buried in the wall and casings or conductors shall be carried so as to allow 1.3 cms air
space on three sides, of the casing conductor.

(b) The conductor shall be carried either in a rigid steel conduit conforming to *IS :
1653-1964 specification for Rigid Steel conduits of Electrical wiring (Revised) or a rigid
non-metallic conduit conforming to *IS : 2509-1963 specification for Rigid Non-Metallic
conduits for Electrical Installations, or in a porcelain tube of such size which permits
easy drawing in. The end of conduit shall be neatly bushed with porcelain, wood or
other approved material.

(c) Insulated conductors while passing through floors shall be protected from
mechanical injury by means of rigid steel conduit (See *IS : 1653-1964) to a
height not less than 1.5m above the floors and flush with the ceiling below.
This steel conduit shall be earthed and securely bushed.

15.2 Where a wall tube passes outside a building so as to be exposed to


weather, the outer end shall be belt mounted and turned down-wards,
and properly bused on the open end.

16.0 Fixing to Walls and Ceilings:

Plugs for ordinary walls or ceilings shall he of well seasoned teak or other approved
hardwood not less than 5 cm long and 2.5 cm. square on the inner end arid 2 cm.
square on the outer end. They shall be cemented into walls to within 7.5 mm ef the
surface, the remaining being finished according to the nature of the surface with
plaster or lime punning.

Signature of Contractor 212


16.1 Where owing to irregular crossing or other reasons the plugging of the walls or
ceiling with wood plugs presents difficulties, the wood casing, wood batten, metal
conduit, or cleat (as the case may be) shall be attached to the wall or ceiling in an
approved manner. IN the case of new building, wherever possible, teak wood plugs
shall be fixed in the walls before they are plastered.

16.2 To achieve neatness, plugging of walls or ceiling may be done by an approved


type of asbestos, metallic or a fiber fixing plug.

17.0 Branch Switches:

Where the supply is derived from a three-wire or four-wire source, and


distribution is done on the two wire system, all branch switches shall be placed in
the outer or live conductor of the circuit and no single-phase switch or fuse shall be
inserted in the middle wire, earth or earthed neutral conductor of the circuit. Single-
pole switches (Other than for multiple control) Carrying not more than 15 amperes may
be of tumbler type which shall be 'ON' when the handle known is down.

18.0 Fittings:

Where conductors are required to be threaded through tubes or channels formed


in the metal work of fittings these must be free from sharp angles or projecting
edges and such size that will enable them to be wired with the conductors used for
the final sub Circuits without removing the boarding, taping or outer covering.
As far as possible, all tubes and channels should be of sufficient size to permit
'Looping back; of wires cables and flexible cords other than those designed for
high temperature shall not be used for wiring fittings except for portable
fittings. All fittings must have not less than a half inch male nipple. Fittings and lamp
holders for gas filled lamps shall be adequately ventilated.

18.1 Where light fitting is supported by one or more flexible cords, the
maximum weight to which the twin flexible cords may be subjected shall be as
follows:

Nominal cross No. & Dia in mm Max. Permissible


sectional Area of wires weight
cord mm2 Kg.

0.5 16/0.2 1.7


0.75 24/0.2 2.6
1.0 32/0.2 3.5
2.5 48/0.2 5.3
3.5 80/0.2 8.8
4 128/0.2 14.0

18.2 NO inflammable shade shall form a part of light fitting unless such shade is well
protected against all risks o1 fire. Celluloid shade or light fitting shall not be used under
any circumstances.

18.3 Fitting of Wire:

Signature of Contractor 213


The use of fitting wire shall be restricted to the internal wiring and the lighting fittings.
Where fitting wire is used for wiring, for the sub-circuit loads shall be terminated in a
ceiling zone or connector from which they shall be carried into the fittings.

19.0 Lamp Holders:

Lamp holders for use on brackets and the like shall be in accordance with
*IS: 1258-1967, specification for Bayonet lamp holders and all those for use flexible
pendants shall be provided with cord grips. All lamp holders shall be provided with
shade carriers. Where centre contact Edison screw lamp holders are used, the outer
or screw contacts shall be connected to the middle wire, the neutral, and the earthed
conductor of the circuit.

20.0 Outdoor Lamps:

External and road lamps shall have weather proof fittings of approved design so
as to effectively prevent the admission of moisture. An insulating distance piece of
moisture proof materials shall be inserted in the fittings. Flexible cord and cord grip
lamp holders shall not be used where exposed to whether. In verandahs and similar
exposed situations where pendants are used, they shall be of fixed rod type.

21.0 Lamps:

All incandescent lamps, unless otherwise required and suitably protected, shall be
hung at a height of not less than 2.5 m above the floor level. They shall be in
accordance with IS : 418 : 1957 specification for Tongster Filament General
Service electric lamp:

22.0 Fans, Regulators and Clamps:

22.1.0 Ceiling fans:

Ceiling fans including their suspension shall conform to *IS 374- 1960 specification for
electric ceiling fans and regulators (Revised) & to the following requirements:
(a) All ceiling fans shall be wired to ceiling roses or to special connector boxes, to
which fans rod wires shall be connected and suspended from hooks or shackles
with insulators between hooks and suspension rods. There shall be no joint in the
suspension rod, but if joints be avoidable then such joints shall be screwed to special
couplers of 5 cm minimum length and both ends of pipes shall touch together within
couplers, and shall in addition be secured by means of split pins; alternatively,
the two pipes may be welded.

(b) Fans clamps shall be of suitable design according to the nature of construction
of ceiling on which these clamps are fitted. In all cases fan clamps shall be
fabricated from tested new metal of suitable sizes and they shall be as close
fitting as possible. Fan clamps for reinforced concrete roots shall be buried
with the casting and due care shall be taken that they shall serve the purpose.
Fan clamps for wood beams shall

Signature of Contractor 214


be of suitable flat iron fixed on two sides of the beam and according to the
size and section of the beam one or two mild steel bolts passing through the
beam shall hold both flat irons together. Fan clamps for steel joint shall be
fabricated from tested flat iron to fit in rigidly to the bottom flange of the
beam. Care shall be taken during fabrication that the metal does not
crack while hammering to shape. Other fan clamps shall be made to suit
the position, but in all cases care shall be taken to see that they are rigid and
safe.

Note : All fan clamps shall be .so fabricated that fans revolve steadily.

(c) Canopies on top and bottom of suspension rod shall effectively hide suspensions
and connections to fan motors, respectively.

(d) The lead-in-wire shall be of nominal cross-sectional area not less than 1.0
mm2 with copper and 1.5 mm2 with aluminium and shall be protected from abrasion.

(e) Unless otherwise specified, the clear distance between the ceiling fan and the
floor shall not be less than 2.75 m.

22.2.0 Exhaust Fans:

For fixing of an exhaust fan, a circular hole shall be provided in the wall to suit the size
of the frame which shall be fixed by means of rag-bolts embedded in the wall. The hole
shall be neatly plastered with cement and brought to the original finish of the wall. The
exhaust fan shall be connected to exhaust fan point which shall be wired as near to the
hole as possible by means of a flexible, cord, care being taken that the blades rotate in
the proper direction.

23.0 Attachment of fittings and accessories:

23.1 In other than conduit wiring, all ceiling crosses, brackets, pendants and
accessories attached to walls or ceilings shall be mounted on substantial teak wood
blocks twice varnished after all fixing holes are made in them. Blocks shall be not less
than 4 cms. deep, Brass screws only shall be used for attaching fittings and
accessories to their base blocks.

24.0 Interchangeability:

Similar part of all switches, lamp holders, distribution fuse- boards ceiling roses,
brackets, pendants, fans and all other fittings of the same type shall be inter-chargeable
in each installation.

25.0 Conduit Wiring System:

25.1.1 Type and size of conduit - All conduit pipes shall be conforming to *IS : 1653-
1964, furnished with galvanised or stove enamelled surface. All conduit accessories shall
be of threaded type and under no circumstances pin grip type or clamp type
accessories be used. No steel conduit less than. 16 mm in diameter shall be

Signature of Contractor 215


used. The number of insulated conductors that can be drawn into rigid steel conduit are
given in Table II.

25.1.2. Bunching of cables - Unless otherwise specified, insulated conductors of


AC supply and DC supply shall be bunched in separate conduits.
25.1.3 Conduit-joints-Conduit pipes shall be joined by means of screwed couplers and
screwed accessories only (*IS : 2667-1964).

Specification for Fittings for Rigid Steel Conduits for Electrical Wiring) In long distance
strance straight runs of conduit, inspection type couplers at reasonable intervals shall
be provided or running threads with couplers and jam-puts (in the latter case the bare
threaded portion shall be treated with anti-corrosive preservative) shall be provided.
Thread on conduit pipes in all cases shall be between 11 mm to 27 mm long sufficient
to accommodate pipes to full threaded portion of coulers or accessories. Cut ends of
conduit pipes shall have no sharp edges nor any buries left to avoid damage to the
insulation of conductors while puling them through such pipes;

TABLE-II MAXIMUM PPERMISSIBLE NUMBER OF 250-V GRADE SINGLE CORE CABLES


THAT CAN BE DRAWN INTO RIGID STEEL CONDUIT

Size of cable Size of conduit (mm)


Nominal Number 16 : 20 : 25 : 32 : 40 : 50 : 63 :
Crossect and
ional Diameter in
area mm of
wires
(No. of cable Max)
S B S B S B S B S B S B S B
1.0 1/1.12 5 4 7 5 13 1 2 14 - - - - - -
0 0
1.5 1/1.40 4 3 7 5 12 1 2 14 - - - - - -
0 0
2.5 1/1.80 3 2 6 5 10 8 1 12 - - - - - -
8
4 1/1.24 3 2 4 3 7 6 1 10 - - - - - -
2
(3/1.06*
)
(7/0.85)
6 1/2.80 2 - 3 2 6 5 1 8
0
7/1.06*)
10 1/3.55+ - - 2 - 5 4 8 7 - - - - - -
7/1.40* - - 2 - 4 3 6 5 8 6 - - - -
16 7/1.70 - - - - 2 - 4 3 7 6 - - - -
25 7/2.24 - - - - - - 2 - 4 3 7 6 9 7
35 7/2.50 - - - - - - - - 2 - 5 4 6 5
50 7/3.00+ - - - - - - - - 2 - 5 4 6

Signature of Contractor 216


* For Cu. Conductors only.

+For Al. Conductors only.

Note : 1 The cable shows the maximum capacity of conduits for the simultaneous
drawing-in of cables. The table applies to 250 volts grade cable. The columns
headed 'S' apply-to runs of conduit which have distance not exceeding 4.25 M
between d/aw in boxes, and which do not deflect from the straight by angle of more than
15°. The co lumns headed 'B' apply to runs of conduit which deflect from the straight by
an angle of more than 15°.
Note : 2 In case of inspection type draw-in box has been provided and if the cables is
first drawn through one straight conduit, then through the drawn box, and then
through the second straight conduit, such systems may be considered as that of a
straight conduit even if the conduit deflects through the straight by more than 15°.

25.1.4 Protection against dampness – In order to minimize condensation or seating


inside the tube, all outlets of conduit system shall be properly drained and
ventilated, but in such a manner as to prevent the entry of insects as far as
possible.
25.1.5 Protection of conduit against rust – The outer surface of the conduit pipes,
including all bends, unions, tees junction boxes, etc., forming part of the conduit
system shall be adequately protected against rust particularly when such system
is exposed to weather. In all cases, no bare threaded portion of conduit
pipe shall be allowed unless such bare threaded portion is treated with anti-
corrosive preservative or covered with approved plastic compound.

25.1.6 Fixing of conduit – Conduit pipes shall be fixed by heavy gauge saddles, secured
to suitable wood plugs or any other approved plug with screws in an approved
manner at an interval of not more than one meter but on either side of couplers or
bends or similar fittings, saddles shall be fixed at a distance of 30 cm. from the
centre of such fittings.

25.1.7 Bends in conduit – All necessary bends in the system including diversion shall
be done by bending pipes, or by insuring suitable solid or inspection type
normal bends, elbows or similar fittings; or by fixing cast iron inspection
boxes whichever is more suitable. Conduit fitting shall be avoided as far as
possible. On conduit system exposed to weather, where necessary, solid type fitting
shall be used. Radius of such bends in conduit pipes shall be not less than 7.5 cm.
No length of conduit shall have more than the equivalent of four quarter bends from
outlet, the bends at the outlets not being counted.

25.1.8 Outlets – All outlets for fitting switches etc. shall be boxes, of suitable
metal or any other approved outlet boxes for other surface mounting or flush
mounting system.

Signature of Contractor 217


25.1.9 Conductors – All conductors used in conduits wirings shall preferably be
stranded. No single - core cable or nominal Cross-sectional area greater than 130
mm2 shall be enclosed in a conduit and used for alternating current.

25.1.10 Erection and earthing of conduit – The conduit of each circuit or section
shall be completed before conductors are drawn in. The entire system of
conduit after erection shall be tested for mechanical and electrtoal continuity
throughout and permanently connected to earth conforming to the requirements
specified under 7 by means of special approved type earthing clamp
efficiently fastened to conduit pipe in a workmanlike manner for a perfect
continuity between each wire and conduit. Gas or water pipes shall not be used as
earth medium. If conduit pipes are liable to mechanical damage, they shall be
adequately protected.

25.2 Recessed Conduit wiring system with Rigid Steel conduits – Recessed conduit wiring
system shall comply with all the requirements for surface conduit wiring
system specified in 6.5.1.1. to 6.5.1.10 and in addition, conform to the
requirements specified in 6.5.2.1. to 6.5.2.4

25.2.1 Making of chase – The chase in the wall shall be neatly made and be
of ample dimensions to permit the conduit to be fixed in the manner desired. In
the case of buildings under construction, chases shall be provided in the wall, ceiling
etc., at the time of their construction and shall be filled up neatly after erection of
conduit and brought to the original finish of the wall.

25.2.2 Fixing of conduit in chase – The conduit pipe shall be fixed by means of staples
or by means of saddles not more than 60 cm. apart. Fixing of standard bends or
elbows shall be avoided as far as practicable and all curves maintained by bending the
conduit pipe itself with a lounge radius which will permit easy drawing-in of conductors.
All threaded joints of rigid steel conduit shall be treated with some approved
preservative compound to secure protection against rust.

25.2.3 Inspection boxes – Suitable inspection boxes shall be provided to permit


periodical inspection and to facilitate removal of wires, if necessary. These shall be
mounted flush with the wall. Suitable ventilating holes shall be provided in the
inspection box covers.

25.2.4 Types of accessories to be used – All outlets such as switches and wall
sockets, may be either of flush mounting type or surface mounting type.
(a) Flush mounting type – All flush mounting outlets shall be of cast iron or mild
steel boxes with a cover
of approved insulating material or shall be a box made of a suitable insulating
material. The switches and
other outlets shall be mounted on such boxes as would be approved. The, metal
box shall be efficiently
earthed with conduit by an approved means of earth attachment.

Signature of Contractor 218


(b) Surface mounting type – If surface mounting type outlet box is specified, it shall
be of any approved insulating material and outlet mounted in an approved
manner.

25.2.5 When crossing through expansion joints in buildings, the conduit sections
across the joint may be through flexible conduits of the same size as the rigid
conduit.

25.3 Conduit Wiring System with Rigid Non-Metallic Conduits:


Rigid Non-Metallic conduits are used for surface, recessed and concealed conduit
wiring.

25.3.1 Type and size – All non-metallic conduits used shall conform to IS : 2509-
1963 The conduit may be either threaded type or plain type as specified in IS :
2509-1913* and shall be used with the corresponding accessories (See IS : 3419-
1965) specification for Fittings for Rigid Non-Metallic Conduits).

25.3.2 Bunching off cables – Conductors of AC supply and DC supply shall be bunched
in separate conduits. The number of insulated cables that may be drawn into the conduits
are given in Table III. IN this table the space factor does not exceed 40 percent.

TABLE-MI MAXIMUM PERMISSIBLE NUMBER OF 250 VOLTS GRADE SINGLE- CORE


CABLE THAT MAY BE DRAWN INTO RIGID NON-METALLIC CONDUITS

Size of cable Size of conduit (mm)


Nominal Number 16 20 25 32 40 50
Crossectiona and
l area mm2 Diameter
in mm of
wires
(No. of cable Max)
1.0 1/1.12* 5 7 13 20 - -
1.5 1/1.40 4 6 10 14 - -
2.5 1/1.80 3 5 10 14 - -
3/1.06*
4 1/1.24 2 3 6 10 14 -
7/0.85*
6 1/2.80 - 2 5 8 11
7/1.06*
10 1/3.55+ - - 4 7 9 -
7/1.40*
16 7/1.70 - - 2 4 5 15
25 7/2.24 - - - 2 2 6
35 7/2.50 - - - - 2 5
50 7/3.00+ - - - - 2 3
19/1.80
Signature of Contractor 219
*For copper conductors only.
+For aluminium conductors only.

25.3.3 Conduit joints - shall be joined by means of screwed or plain couplers depending
on whether the conduits are screwed or plain. Where there are long runs of straight
conduit. Inspection type couplers shall be provided at intervals. For conduit fittings and
accessories reference may be made to IS : 3419-1965.

25.3.4 Fixing of conduits – The provision of 25.1.6 shall apply except that the spacing
between saddles or supports is recommended to be 60 cms for rigid non-metallic
conduits.

25.3.5 Bends in conduit – Wherever necessary, bends or diversions may be achieved by


bending the conduits (See 6.5.3.9) or by employing normal bends, inspection bends,
inspection boxes, elbows or similar fittings.

25.3.6 Conduit fittings shall be avoided, as far as possible on outdoor system.

25.3.7 Outlets – All the outlets for fittings, switches, etc. shall be boxes of substantial
construction. In order to minise condensation or sweting inside the conduit, all
outlets of conduit system shall be properly drained and ventilated, but in such a
manner as to prevent the entry of insects, etc. as far as possible.

25.3.8 For use with recessed conduit wiring system the provisions of 6.5.2.1 to 6.5.2.4
shall apply.

25.3.9 Heat may be used to soften conduit for bending and forming joints in case of
plaint conduits. As the material soften when heated, fitting of conduit in close proximity
to hot surfaces should be avoided. Caution should be exercised in the use of the conduit
in locations where the ambient temperature is 50°C or above. Use o f such conduits in
place where ambient temperature is 60°C or above is prohibited. -PVC INSULATED AND
P.V.C. SHEATHED OR T.R.S. WIRING SYSTEM

26.0 GENERAL

This system of wiring, is suitable for low pressure installation, and shall not be used in
places exposed to sun and rain nor in damp places, provided they are sheathed in the
special approved protective covering and well protected to withstand dampness.

26.1 Attachment to walls and ceiling:

26.1.1 All cables on brick walls, stone or plastered walls and ceiling shall be run on well
seasoned, perfectly straight and well varnished on four sides, teak wood or any
approved hardwood battens not less than 10 mm finished thick, width of which shall be
such as to suit total width of cables laid on the batten, prior to election, these shall be

Signature of Contractor 220


painted with one coat of varnish or approved paint of colour to match with surrounding.
These battens shall be secured to wall and ceilings by flat head wood screws to raws
plug or phill plug at an interval not exceeding 75 cm. Wood plug can be used only
with special approval of the En-gineer-in-charge. The flat head wood screws shall
be counter within wood batten and smoothed down with file.

26.1.2 Where wiring in to be carried out along the face of the rolled steel joints, a
wooden batten of adequate width shall first be laid on the same and dipped to it as
inconspicously as possible. The wiring should then be fixed to this backing in the ordinary
way. Where wiring passes through structural steel work, the holes shall be suitably bushed
to prevent the abrasion of the cables.

26.1.3 Attachment to false ceiling: In no case, the open wiring shall be run above the
false ceiling without the approval of Engineer-in-charge.

26.20 Link dips: Only aluminium alloy clips/joint clips shall be used. The thickness shall
be 0.32 mm (30 SWG) for lengths of 25 mm to 40- mm and 40 mm (28 SWG) for lengths
of 50 mm to 80 mm. The width shall not be less than 8 mm in all these cases. Link
clips/joint clips shall be so arranged that one single clip shall not hold more than two core
or three single core TR3 of PVC insulated and PVC sheathed upto 2.5 sq. mm above while
a single clp shall hold a single twin core or two single core cables. The clips shall be fixed
on varnished wood batten switch iron pins and space at interval of 15 cm both in the
case of horizontal and vertical runs.

26.3.0 Bends in wiring: The wiring shall not in any circumstance? x bent so as to form an
abrupt right angle but must be rounded off at the comers to a radius not less than six
times the overall diameter of the cable.

26.4.0 Protection of wiring from Mechanical Damage:

26.4.1 In cases where there are chances of any damage to wiring, such wiring shall be
drawn complying with all the requirements of conduit wiring system.

26.4.2 Such protective covering shall in all cases be fitted on all down drops within 1.5 m
from the floor, or from floor level upto the switch board whichever is less.

26.5.0 Passing through floors: All cables taken through floor shall be enclosed in
heavy gauge steel conduit extending 1.5 m above the floor or upto the switch board
whichever is less and flush with the ceiling below or
by means of any approved type of metallic covering. The ends of all conduits or pipes shall
be neatly bushed with porcelain wood or other approved material. The conduit pipes, shall
be securely earthed.

26.6.0 Passing through walls: When conductors pass through walls, any one of
the following methods shall be employed. Care should be taken to see that wires pass
very freely through protective pipe or box and that wires pass through in a straight line
without any twist or cross in wires on either ends of such holes.

Signature of Contractor 221


(a) A box of teak wood or approved hard wood extending through the hole
thickness of the wall shall be buried in the wall and casings or conductors
and casing or conductors shall be carried so as to allow 1.3 cm air space on
the three sides of the casing or conductor.

(b) The conductors shall be carried in an approved heavy gauge solid


drawn or lap weld conduit or in a porcelain tube of such a size that it
permits easy drawing in, the ends of conduit shall be neatly bushed with
porcelain, wood or other approved material.

26.6.1 Where a wall tube passes outside a building so as to be exposed to


weather, the outer end shall be bell mouthed and turned downwards and properly
bushed on the open end. The conduit shall be neatly arranged so that the cables enter
them without bending.

26.7.0 Buried cables: The TRS or PVC sheathed cable shall not normally be
buried directly in plaster. Where so specified in the special specification they may be
taken in teak wood channeling of ample capacity or conduit pipe buried in the wall.

26.8.0 Stripping of outer covering. While cutting and stripping of the outer covering of
the cable, care shall be taken that the sharp edge of the cutting instrument does
not touch the inner insulation of the conductors. The protective outer covering
of the cables shall be stripped off near connecting terminal and this protective
covering shall be maintained upto the close proximity of connecting terminals as far as
practicable. Care shall be taken to avoid hammering on link clips with any metal
instrument after the cables are laid. Where junction boxes are provided they shall be
made moisture proof with a plastic compound.

27.0 PAINTING WORK IN GENERAL:

27.1 Paints: Paints, oils, varnishes, etc. of approved make in original to the
satisfaction of the Engineer-in-charge shall, only be used.

27.2 Preparation of surface: The surface shall be thoroughly cleaned and dusted
before painting is started. The proposed surface shall be inspected by Engineer-in-
charge or his authorized agent and shall have received the approval before painting is
commenced.

27.3 Application: Paint s hall be applied with brush. The paint shall be
spread as smooth & even as possible. Particular care shall be paid to rivets, nuts,
bolts and cover lapping. Before drawing cut, it shall be continuously stirred in the
smaller containers with a smooth stick while it is being applied.

Each coat shall be allowed to dry out sufficiently before a subsequent coat is applied.
27.4 Scope: Painting on old surface in indoor situations will not include primer
coat except where specially mentioned in the schedule of work or special specification.
However, where rust has formed on iron and steel surfaces the spots will be painted with
one anti-rust primer coat

Signature of Contractor 222


27.5 Precautions: All furniture fixtures, glazing floors, etc. shall be protected
by covering. All stains, smears, splashing, dropping of every kind shall be
removed. While painting of wiring etc. it shall be ensured that painting of wall
and ceiling etc. is not spoiled in any way.

27.6 Painting of conduit and accessories: After installation, all accessible surface of
conduit pipes, fittings switch and regulator boxes, etc. shall be painted with two
coats of approved enamel paint or aluminium paint as required to match the finish
' surrounding wall, trusser, etc.

28. Link clip:

The clip for batten wiring shall be of Aluminium conforming to I.S. specification No. 2415-
1975

APPENDIX-'A'
Important Clauses of Indian Electricity Rules 1956. Following clauses of Indian Electricity Rules,
1956 shall in particular be taken care of in the execution of
electrical works

Clause No. Subject

3. Authorization:

29.Construction, installation, protection, operation and maintenance of electric supply lines and
apparatus.

31.Cut-out on consumer's premises.

32.Identification of earthed and earthed neutral conductors and position of switches-and


cutouts therein.

33.Earthed terminal on consumer's premises.

36.Handling of electrict supply lines and apparatus.

41.Distinction of circuits of differents voltages.

42.Accidental charge.
Signature of Contractor 223
43.Provisions applicable to protective equipment.

44.Instructions for restoration of persons suffering from electric shock.

45.Precautions to be adopted by consumers, owners, electrical contractors, Electrical workmen


and suppliers.

46.Periodical inspection and testing of consumer's, installation,

48.Precautions against leakage before connection.

50.Supply to consumers.

51.Provisions applicable to medium, high voltage installations.

58.Point of commencement of supply.

59.Precautions against failures of supply; Notice of failures.

61.Connection with earth, (Low and Medium Voltage system).

64.Use of energy at high and extra-high voltage system.

67.Connection with earth. (High & Extra-high voltage systage.)

68.General conditions as to transformation and control of energy. All clauses under Chapter VIII
on Overhead Lines!

137.Mode of entry.

138.Penalty for breaking seal.

139.Penalty for breach of rule 45.

140.Penalty for breach of rule 82.

141.Penalty for breach of rules

Signature of Contractor 224


APPENDIX -'B'
Form of Completion Certificate

I/We certify that the installation detailed below has been installed by me/us and tested and
that to the best of my/our knowledge and belief, it complies with Indian Electricity Rules
1956, as well as the C.P.W.D. General Specification for Electrical Works 1972.

Electrical Installation at Voltage and system of supply

(1) Particulars of works :


(a) Internal Electrical No. Total Load of wiring Type or system
Installation
(i) Light point
(ii) Fan point
(iii) Plug point
(a) 3 pin 5 Amp.
(b) 3 pin 15 Amp.

(b) Others :
Description HP/KW
(a) Motors : (i)
(ii)
@X1= (iii)

Signature of Contractor 225


(c ) Other Plants :

(d) If the work involves installation of over head line / or under ground cable
:
(a) (i) Type & Description of overhead line.
(ii) Total length & No. of spans.
(iii) No. of street light & its description.
(b) (i) Total length if under ground cable & its size.
(ii) No. of joint.
End joint :
Tee joint :
St. through joint :

(2) Earthing :
(i) Description of earthing electrode :
(ii) No. of earth electrodes :
(iii) Size of main earth lead :

(3) Test Result :


(a) Insulation Resistance :
(i) Insulation resistance of the whole system of conductors to earth. Megohms.
(ii) Insulation resistance between the phase conductors and neutral. Megohms.
Between phase R and neutral Megohms.
Between phase Y and neutral Megohms.
Between phase B and neutral Megohms.
(iii) Insulation resistance between the phase conductors in case of
polyphase supply
Between phase R and phase Y Megohms.
Between phase Y and phase B Megohms.
Between phase B and phase R Megohms.

(b) Polarity Test :


Polarity of non linked single pole branch switches.

(c) Earth continuity Test :


Maximum resistance between any point in the earth continuity conductor metal conduits &
main earthing lead.

(d) Earth Electrode Resistance :


Resistance of each electrode.
i) ohms
ii) ohms
iii) ohms
iv) ohms

(e) Lighting protective System :


Resistance of the whole of lighting-protective system to earth before any bonding is
effected with electrode and metal in/on the structure.
ohms

Signature of Contractor 226


Signature of Supervisor Signature of Contractor

Name & Address Name & Address

SPECIFICATIONS

All Specification, standard, publication etc. specified mean the latest standards,
publication etc. pertaining to Electrical Installation and should conform to the following
wherever applicable.

1) Indian Electricity Act 1910 with its amendments.

2) Indian Electricity Rules 1956 and its amendments.

3) Indian Electricity supply Act, 1948.

4) Regulation for Electrical Equipment in building by I.E.F. London.

5) The Factory Act 1948 and its amendments.

6) I.S.-732-1982 Part-l, II & III code of practice for Eletrical wiring and fittings in
buildimgs for low and medium voltages.

7) I.S. 4064-1967 H.D. Air break switches and fuses for Voltages not exceeding 1100
volts.

8) I.S. 3043 – Earthing code of practice for

Signature of Contractor 227


9) I.S. - 1554 Part-l - 1970 PVC insulated (Heavy duty) Electrical Cables for working
voltages upto and including 1100 volts.

10) IS : 694 - 1964 Part-ll - PVC insulated cable with Alluminium conduits (revised) for
voltages upto 1100 volts.

11) IS : 5908-1970 - Electrical installations in buildings, method of measurements of.

12) IS : 4237-1967 - General requirement for switchgear and control gear for voltage not
exceeding 1000 volts.

13) IS : 1653-1964 - Rigid steel conduits for electrical wiring (revised).

14) IS : 2509-1973 - Rigid steel conduits for electrical installation. (First revision).

15) IS : 1258-1967 - Beyonet landholders (First revision)

16) IS : 418-1957 - Tungsten-Filament General service electric lamps (Third revision)

17) IS : 374-1966 - Fans and Regulators, ceiling type, electric (Second revision)

18) IS : 2667-1964 - Fittings for rigid steel conduits for electrical wiring.

19) IS : 3419-1976 - Fittings for rigid non-metallic conduits (First revision)

20) National Electric Code, 1986

ANNEXURE-I
Abstract of the Wiring Rules of the Institution of Electrical Engineers
(referred to in the specification)

Systems:

All electrical system in which all the conductor and apparatus are electrically connected to a
common source of

1) Earthed: Effectually connected to the general mass of the earth. Solidly earthed
means earthed without the Intervention of a fuse, switch, circuit-breaker, resistor, reactor or
solenoid.

2) Uninsulated Conductor: A conductor without provision, by the interposition of a dielectric


or otherwise, for its insulation from earth.

3) Bare: Not covered with insulating material

4) Dielectric: Any material which offers high resistance to the passage of an electric
current.

Signature of Contractor 228


5) Bunch Conductor: When more than one conductor is contained within a single duct or
groove or when they are run enclosed and not spaced apart from each other.

6) Points: In wiring as per IS : 5908-1970-Method of measurements of electrical installation


in Buildings

7) Switch board: An assemblage of switchgear with or without instruments, but the term
does not apply to a group of local switches in a final sub-circuit where each switch has its own
insulating base.

Note : In the electricity (Factories Act) special regulations 1908 and 1944, the term
"Switchboard" includes "Distribution board".

8) Single pole switch: A switch suitable for closing and or opening a circuit on one phase or
pole only.

9) Linked switches: A switch the blades of which are so linked mechanically as to


make or break all poles simultaneously or in a definite sequence.

10) Fuse Switch: A switch the moving part of which carries 'one or more fuses.

11) Three Wire System:


a) Outer Conductor: Those between which there is the greatest difference of potential.
This use of the word outer must not be confused with the use of the work when,
applied to the external conductor of a concentric main.

b) Neutral Conductors: The term includes the natural conductor of a 3 phase 4 wire system,
the conductor of a single phase or d.c. installation which is earthed by the supply
undertaking (or otherwise at the source of the supply) and the middle wire or common
return conductor of a 3 wire d.c. or single phase a.c. system.

12) Semi enclosed machine: One in which the ventilating openings in the frame are covered
with-

a) Grids, expanded metal or wire gauge, with openings of less than 1/4 inch so as
to obstruct free ventilation.

b) Wire gauge, in which the openings are less than 1/4 inch but not less than 3/32 inch
(diameter or width):

c) Screens with smaller openings than the above.

13) Totally – enclosed Machine:

One in which the enclosing case and bearings are dust proof and which does not allow
circulation of air between the inside and outside of the case
14) Pipe Ventilated Machine: An enclosed machine in which the frame is so arranged that the
ventilating air may be conveyed to it through a pipe attached to the frame, the ventilation
opening maintained by the fanning action produced by the machine - itself.
Signature of Contractor 229
15) Forced draught machine: An enclosed machine in which the ventilating air supply is
maintained by an independent fan external to the machine itself.

16) Protected Machine: One having end shield bearings and in which there is free
access to the interior without opening doors or removing covers

SWITCHES AND CIRCUIT BREAKERS

(See clause II of Specifications)

17) Switches and Circuit Breakers:

Switches and circuit breakers (rules 2b. 36 and 37), whether fixed separately or
combined with lamps, holders or fittings, must comply with the following requirements:

(a) Overt heading must not take place at the point of contract or -elsewhere,
when the full current flows continuously.

(b) They must be so constructed or arranged that the contracts cannot accidentally
close when left open.
(c) The basis must be of incombustible, non-conducting and moisture proof
material.

(d) Circuit breakers must be so arranged and placed that no combustible


material is endangered by their action.

(e) Unless placed in an engine room or in a compartment especially arranged for


the purpose, they must have their live parts covered. The covers must be
of incombustible material and must be either non- conducting or of rigid
metal and clear of all internal mechanism. For more than 6 amperes, at
pressures exceeding 125 Volts metal covers must be lined with insulating
material.

(f) In positions where they are liable to injury or come into contact with
goods, they must be further protected by an open fronted box or other
suitable guard.

(g) Handles must be insulated and so arranged that the hand cannot touch live
metal, or be injured through and adjacent fuse blowing.

(h) Switches having a handle projecting through an open slot in the cover, must not
be used.

Signature of contractor/s
Executive Engineer

SECTION F-1A
Signature of Contractor 230
GENERAL REQUIREMENTS

1.1 Scope of Works:

The work covered by electrical specification consists supplying and installing, electrical
wiring system complete in strict accordance with this specification and the applicable
drawing and subject to the terms and conditions of the contract. It includes.

(a) Conduit and wiring system for fans, lighting points, bells, clocks, sockets etc.
including fixing of lighting fixtures and fans etc. and miscellaneous points.

(b) Conduit and wiring system for exhaust fans, power sockets etc.

(c) Panel boards, distribution boards, switch fuse units.

(d) Complete power and lighting cable systems.

(e) Grounding system.


(f) Conduits for Telephone system.
(g) Street lighting system.

(h) Other miscellaneous electrical work.

1.2 Completeness of Contract:

Any work fittings, accessories or apparatus which may not have been specifically
mentioned in the specification but which are necessary in the equipment for efficient
working of the plant should be deemed to be included in the contract and should be
executed and provided by the contractors. All plant and apparatus should be complete
in all the details, where such details, are mentioned in the specifications or not.

Three prints and one permanent negative of each of the finally approved
drawings incorporating all the modifications proposed by the Department should be
submitted. No modifications should be made in a drawing already approved by the
Engineer-in-charge without his prior consent.

Approval of the contractor's drawing will not relieve the contractor of any part of his
obligation to meet all the requirements of the contract.

1.3 Guarantee:

The performance of all the equipments and the installations should be guaranteed at
least for a minimum period
of one year from the date of taking over the installation by the Department. All
equipments must comply with the relevant IS-BS specifications

1.4 Interchangeability:

Signature of Contractor 231


All corresponding parts of similar plant and equipment should be interchangeable in
every way.

1.5 Tools:

All special tools required for dismentling and assembly of the equipment covered
by the contract shall be supplied as obligation under the contract.

A list of items to be supplied by the Contractor should be submitted alongwith the


tender.

SECTION F-2A

Specifications for Electrical Installation in Buildings

i. GENERAL

1.1 These specifications relate to the electrical installations in the buildings of P.W.D.
Electrical. The specifications cover general requirements to be fulfilled. These general
specifications are supplemented by the specifications for the particular buildings separately
attached.

1.2 These specifications are governed by the General conditions of the contract attached
hereto.

1.3 APPLICABLE RULES AND REGULATIONS:

1.3.1 Installation shall be carried out in conformity with the regulations for electrical
equipments of buildings, published by the Institute of Electrical Engineers London (14th
Edition 1966 and as amended upto date) herein after referred to as the I.E.E. wiring
regulations. Where these specifications or the special specifications for the- particular
building attached hereto are at variance with the I.E.E. regulations these specifications
or special specifications as the case may be shall be followed. The installation shall also comply
with the requirements of the Indian Electricity Act, 1910 as amended upto date and rules issued
there under and also the regulations for the Electrical Association of India. Where not
specified otherwise, the installation should generally follow the Indian standard codes of
practice and in their absence the relevant British Standard of practices. All the materials shall
comply with the relevant Indian Standard or British Standard specifications.

1.4 DEFINITIONS:

1.4.1 The definitions of terms in the I.E.E. regulations shall apply in general.

1.5 DRAWINGS:

Signature of Contractor 232


1.5.1 The preliminary drawings only indicate the general scheme of requirement. The
exact position of all points, control switch boxes, runs of wiring and/or conduits joint
boxes, inspection boxes, mains, and sub distribution boards, mains etc. shall be got
approved by the Engineer-in-charge. All circuits shall be clearly numbered in wiring
diagrams and building plans. The detailed design of a switch-board, special fixture or any other
part of the electrical installation as may be called for by the engineer-in-charge shall also be
supplied by the Contractor and should be got approved by the Engineer-in-charge. Three
sets of completion drawings and wiring diagrams showing the installations as executed shall
be supplied by the contractor along with the completion certificate.

1.6 MATERIALS:
All materials shall be new and of the best quality conforming to the relevant I.S.B.S.
specifications. They must be the products of reliable manufacturers of many years or
standings. All like parts of materials shall be interchangeable. In case of equipments
such as circuit breakers, switch fuses etc. a descriptive and illustrated literature shall
accompany the tender. The names of manufacturers of various materials shall be
furnished in Performa in Appendix-l. Samples of materials wherever required should be
approved by the Engineer-in-charge before use in the installation. One set of such approved
samples shall be deposited with the Engineer-in-charge.

All materials shall be rust-proof or rendered rust proof by application of suitable paints.
The Supply of all equipments, switchgears etc. shall be complete with accessories, fittings and
mountings as may be required for their proper performance, and as specified in the relevant IS-
BS Code of Practice and standards

1.7 WORKMANSHIP:
1.7.1 Good workmanship and neat finished appearance are the prerequisites for complying
with the clauses of these specifications. With a view to ensure fine workmanship
the tenderers shall employ licensed wiremen, with an experience of not less that
5 years in the type of work they are engaged. The work should be done under the
supervisions of licensed Electrical Supervisors with good educational qualifications and
considerable experience.

1.7.2 Tenderers, shall furnish the names of Supervisor and their wiremen who will be engaged
in this work with details of their experience.

1.8 CO-OPERATION WITH CIVIL AND OTHER WORKS CONTRACTORS :

1.8.1 The tenderer, after the award of the contract, shall co- operate with the civil and other
contractors and shall co- ordinate his work with the work of other contractors with
.the least amount of dislocation and interference to the other works Tenderers shall
go through the drawing carefully and shall furnish the Engineer-in-charge with all the
details of openings in the walls etc. they may be required for concealing any
of the electrical equipments or accessories. Where the contractor fails to furnish
such information as may be required for the purpose of concealing the
equipments etc. they shall be made at his (Contractor) cost and expense. Any
alteration to parts f the building shall be carried out with prior permission of the

Signature of Contractor 233


competent authority. All chaises of the structural work shall be made good at the
contractor's expense and brought to the original shape finish and colour.

1.9 TESTING:
The electrical contractor shall be completely responsible for the 'testing and
commissioning of those installations covered by these specifications in compliance
with the standard procedure, in obtaining permission of the Government
Electrical Inspector. Any modification which is demanded by Government Electrical
Inspector shall have to be carried out within the scope of the contract. The
contractor shall submit four copies of drawings of installations as per regulations for
shall be provided by the contractor for carrying out the installation work. All tests
shall be carried out in the presence of the Engineer-in-charge or his
authorized representative and his approval obtained for the test results.

1.10 COMPLETION CERTIFICATE AND MAINTENANCE GUARANTEE:

1.10.1 After the completion of the installation and testing, the contractor should furnish a
certificate in the proforma in Appendix-Ill, at the time of taking over the installation by
the Department. The installation shall be guaranteed for period of 12 months from the
date of taking over by the Department. During the period of guarantee all defects in
material or in workmanship shall be rectified or replaced free of cost to the
Department.

1.11 TENDERER'S ABILITY:

1.11.1 In order to enable the Department to asses the ability of the tenderer to
execute the work, the tenderer shall furnish evidence of his experience and capacity to
carry out the work of the magnitude and nature.

1.12 RATES:

1.12.1 The rates of items shall include all taxes, transport, loading and unloading charge and
all such charges that may be required to be incurred for the supply and installation of
the materials at site. The rates shall be firm and variations in the market are not
entertained. Break up figures as required in the schedule of work shall also be furnished. As
far as possible indigenous materials only shall be included for supply. Where it is
unavoidable, imported items may be included and tenderer should clearly indicate
materials, quantity, rate and amount of these items.

1.13 STORAGE SPACE:


No covered storage space will be provided by the Department. The contractor has to
make his own arrangement, However the Department may give an open space near
the place of execution where the contractor can build his own stores for executing the
work.

1.14 DEPARTURE FROM SPECIFICATIONS:

Signature of Contractor 234


The tenderer should clearly indicate departure, if any, from the specifications with
reasons for the same.

1.15 EXTRA ITEMS:


Rates for extra items shall generally be derived from the rates already available in the
schedule. Where it is not possible, the rates shall be mutually agreed upon and the
contractor shall furnish a detailed analysis of the rates claimed by him.

2. TECHNICAL SPECIFICATIONS:

2.1 Supply System:


The wiring installation shall be suitable for 3 phase 4 wire, 400-440 V 50 cycles system
of supply. Colour code of different phase shall be followed as per standard.

2.2 Wiring for Lights and Fans:

2.2.1 Looping system of wiring shall be adopted. No joints shall be made at intermediate runs
of cables and where they are unavoidable, such joints shall be through approved
mechanical connections.

2.2.2 Point wiring:


Point wiring shall consist of the branch wiring from the switch board together with the
controlling switch or push
as far as and including the ceiling rose or any other approved connector or socket,
outlets. In case of more than one light being controlled by one switch, the wiring up to
the ceiling rose of the first light including the switch shall
be considered as a 'Primary point, Loop wiring from light shall be considered as a
'Secondary' point and rates shall be quoted separately, including final connections to
fixtures and plugs.

2.2.3 Conductors:
No conductor for final sub circuit wiring for light and socket outlets shall have across-
section less than that of 2.5
sq.m. (aluminium).

2.2.4 Loading:

No final sub "limit radiating from the fuse board of a sub- distribution board and wires with 25
sq. m. (Al.) cable shall carry more than 10 lights, fans or socket outlets or a connected load of
800 watts whichever is greater. The following wattages may be assumed for estimating the
load on each sub-circuit unless otherwise known or specified.

Incandescent Lamps 100 watts


Ceiling fans 60 watts
5-A Socket Outlets (lighting) 100 watts
Signature of Contractor 235
4 ft. fluorescent tube 50 watt
5 ft. fluorescent tubes 100 watts

In each sub-distribution board at least one way preferably two ways shall be left spare for
future requirement. A wiring diagram giving the details of the exact utilization of the
ways shall be prepared and fixed in the sub- distribution .board itself or any other
family accessible place. The ways of sub-distribution boards shall be accordingly
numbered.
2.2.5 Local Control Switches (General):
Local control switches for circuits carrying not less than 5-A shall be piano type and
shall conform to relevant I.S. Standards. The switch shall .be 'ON' when the knob is
in the down position. All local control switches shall be connected in the phase or
live conductor only and not in the neutral conductor, switches shall be fixed in iron
clad box and shall be so placed that the centre of the switch box is 1.3 mtr.
from the finished floor level unless otherwise stated. All switch boxes shall be
provided with 1/8" thick Perspex cover fixed to the switch box with chromium plated
counter sunk screws (brass).

2.2.5A Switches (Two way):


(a) Two way switches shall be piano type single pole, double throw, 250V, suitable
for flush mounting and of 5A capacity as per the drawings. All switches shall be recessed
in an embedded metal box.
(b) Each box shall have suitable outlet for fixing conduits directly.
(c) Each box shall have Perspex cover painted inside with the wall colour, if
required.
(d) Each switch shall be suitable for the position in a corridor stairway wiring.

2.2.5B Switch Boxes (General):


Electrical circuits shall be written suitably on the cover of all switch boxes, as
approved by the Engineer-in- charge (Elect) whenever different phase are
terminated in a switch box bakelite partition shall be provide. Each case shall be
provided with a G.I. Earth stud nut and washers for earth connectors.

2.2.6 Ceiling Rose:


Ceiling rose shall be used on circuits having a voltage normally exceeding 200V. Only
one flexible cord shall be attached to a ceiling rose. Only 3-pin 5A socket outlet shall
be provided in lighting circuits. All socket outlets shall be provided with a control
switch and they shall be mounted in switch boxes in an approved manner.

2.2.7 Fittings:
These shall be of approved type as specified in the tender schedule. The sub circuits
leads should terminate in
a ceiling rose or conductor in the fitting and internal connection made there from.
Wherever these fitting are suspended they shall be done so through the conduits and
ball and socket joints. All fittings shall be grounded
by a G.I. conductor not less than 16 S.W.G.
Signature of Contractor 236
2.2.8 Flexible wiring:
Flexible cords of not less than 23/0076 size shall be used. The weight of
suspension shall be governed by I.E.E. Regulations.

2.2.9 Ceiling Fans:


All ceilings fans shall be wired to ceiling rose and suspended from a hook shackle or
clamp and insulated from the same. All joints in the suspension road shall be
screwed and secured by means of split pins. The fan clamps supplied by the
Contractor shall be suitable for the ceiling or proof member as the case may be. For
Concrete roofs, fan hooks shall be buried in concrete during contraction in an
approved manner and securely bound to the reinforcement.

2.2.10 Conduits and Earthing:


All conduits feeding lighting and fan circuits shall be provided with earth continuity G.I.
conductor as specified for power wiring. All conduits shall be as specified for power wiring

2.3.1 Point wiring:


Point wiring for power shall be as defined under section. 2.2.2 and shall include the
switches and sockets.

2.3.2 Loading:
All distribution board for power wiring shall be not less than 15A per way. Loading
per way shall not exceed normally 100 watts. The following loads may be assumed if
exact figures are not known.
3-Pin 15A Outlets 1,000 Watts
3-Pin 5A Outlets 100 Watts

2.3.3 Wiring for Motors:

2.3.3.1 Final sub-circuits loop in motors shall be connected to separate ways of the
Distribution board even if the current in the sub-circuit is less then 15A. No looping
is permissible.

2.3.3.2 All wiring shall be carried in H.G. conduit as specified in I.S. specification
for gauge for different sizes of conduits. When the motor is resiliently mounted
flexible conduit with approved adopters shall be used for the last few feet. Where
cables are used sufficient loop shall be left.

2.3.3.3 All switch fuse units controlling circuits feeding motor shall be provided with H.R.C.
fuses or as specified.

2.3.3.4 The frame of every motor and its association control gear shall be earthed by
two separate and distinct connections to earth connector shall be capable of carrying
3 times the rating of fuse or 1.1/2 time the setting or the circuit breakers but in no
case less than No. 8 S.W.G. or 7064" or equivalent cross section of copper. Where

Signature of Contractor 237


practicable, the earth connections shall be visible for periodical inspection. Gas or
water pipes shall not
be used for earth connections.

2.3.3.5 Socket Outlets and Control Switches 5A and 15A:

All socket outlets shall be of 3 pin type, the third pin being connected to the earth
stud of nearest distribution board by separate earthing wire. The socket shall
conform to IS : 1293/1938, single pole, piano type. Each socket outlets shall
be provided with a control switch of appropriate rating and as specified. The switch
and socket shall be mounted inside the iron clad box provided with 1/8" Perspex
cover as directed by the Engineer-
in-charge or as specified in schedule of quantities. Inside switch box ample space
shall be available around switches for connecting wires to switches. All socket
outlets for power shall be mounted at the skirting level unless otherwise specified
or as directed by the Engineer-in-charge.
The three phase plug receptacles shall have their earth terminals connected by
independent earth wires to ring main earth strips on the building. In buildings
where explosion proof fixtures are installed single phase plug receptacles as well
as light points shall be connected to ring main ground bus installed in the
building by separate; earth wires of approved size.
Socket outlet shall have some provision not to receive the matching plug unless the
grounding pin is in correct position. The grounding pin of the plug shall make the
contract first and break the contract last at the of time of inserting or removing the
plug respectively.
The grounding terminal shall be connected to the enclosed metal body by
providing G. I. stud, nut washers welded to the box.
Each unit shall be suitable for flush mounting as required and indicated in the
applicable drawings.
Combination unit of socket outlet and switch shall be complete with
necessary internal wiring. The switch/socket shall be mounted on M. S. bracket
enclosed in a box.

2.4 Conduit Wiring

2.4.1 Where conduit wiring is adopted the type and size of the conduit shall be as
indicated in the drawing. The minimum of the conduit shall be 19 mm

2.4.2 The contractor shall thoroughly study the structural and architectural
arrangements of the buildings and wherever, necessary shall in consultation with
Department's representatives at site, make suitable adjustments in the cable routings,
earthing arrangements, and location boxes, fittings etc. with a view to avoid
interference with any part of the building, structure, equipment or any other
work in the building or to effect any improvement in the arrangement.

2.4.3 Protection of conduit against rust:

Signature of Contractor 238


Conduit shall be given two coats of oxide paint before they are placed in position. All
exposed conduit shall be painted after installation with the colour as approved
by the Engineer-in- charge. This do not apply to galvanized conduit.

2.4.3 A Protection against insects and damp:


In order to minimize cocensation or sweating inside the conduit, system shall
be properly drained and ventilated in such a manner as to prevent the entry of
insects.

2.4.4. Conduit shall first be installed as a complete system without cables and shall
be continuous from outlet to outlet from fitting to fitting and mechanically and
electrically connected to all boxes and fittings.

2.5 SPECIFICATION FOR POWER CONTROL AND TELEPHONE CABLES:

1. SCOPE:
i. The specifications cover the supply and installation of medium voltage power
and control cables either in ground or trench depending on the conditions
at site including accessories for the same. The work in general, consists of
supplying, laying, jointing terminating and connecting all 11 KV APLSTS PVC
power and control-cables.
ii. The contractor shall supply all accessories including jointing and terminating
materials, compound, tapes supporting materials, cleats cables lugs, concrete
stabs, bricks sand, cable markers etc, as required to make the installation work
including digging and backfilling of the trenches as required.

II. SPECIFICATIONS
i. All power cables to be supplied mentioned as 'APLSTS' in the Schedule should
be mass impregnated, non-draining, paper insulted lead sheathed, double
steel tape armored and must comply with the latest ISI BS specifications.
ii. All cabling materials such as cable compound, cable lugs, tapes, shall be of
approved quality acceptable
to the type recommended by the manufacturer of the cable for which it
is and approved by the
Department
iii. Installation of all equipment shall also conform to the applicable. Codes and
practice as per the IS and shall be executed to comply with the lattes
Indian Electricity rules as regards the safety, earthing of equipments and
other essential provisions specified therein.
iv. Only approved make of cables shall be used. ICC and CCI will be preferred
v. The cables shall generally be laid as per IS code of practice.

III. GENERAL RULES FOR CABLE LAYING:

i. Installation shall be carried out in a neat, workman like manner by skilled


experienced and competent workmen in accordance with the standard .practices.
ii. Cables shall be laid preferably in one piece length to avoid joints. If straight
joints are found necessary, these can be introduced with prior approval of

Signature of Contractor 239


the Engineer-in-charge. The cost of the straight joint however, shall not
be borne by the Department, But in no case joint shall be within the conduit,
G. I. pipe and duct.
iii. Proper care should be exercised in handling the cable to avoid formation
of kind etc. and should it become necessary a cable shall be bent to a radius
not less than 20 times the overall diameter of the cable
iv. Method of installation, routing of cable etc. shall in every case be subject to
the Department's approval and the contractor shall modify and or certify
at no extra cost to the Department any portions of the installation which
do not meet with the Department's approval. All damages to the civil and other
works on this account shall be made good by the contractor at no extra cost to
the Department.
The electrical contractor while notifying the building contractor for such
work shall furnish the proper drawings, fully explaining the work involved or
indicate at site actual work to be carried out as may be required by the
building contractor. The electrical contractor shall also notify the building
contractor in writing, for finishing up as required, of any such work as soon as
the electrical work with respect to the same has been completed.
v. Where cables pass through hume pipes, contractor shall fix hard wood bushed
round the cables at the ends of hume pipes. Where the cables pass through the
floors or chambers and in such other situations as the Engineer shall require, the
contractor shall seal cabbie holes in a manner approved by Engineer-
in- charge. Where cable pass through roads, nallahs, etc. cables must be
protected by Class 'A' Hume pjpe of diameter not less than 6" (15 cms).
vi. The cable route shall be the shortest and these shall be minimum interference
with built up areas, lawns etc
vii. Care shall be exercised for providing suitable props for supporting other service
lines on earth at the time of excavation. Where cutting of a lawn become
inevitable it should be with the approval of the Engineer- in-charge.
viii. Excavation of the trenches shall be executed with vertical sides and the trenches
shall be kept as straight as possible. The exact location of each trench shall
be settled by the Engineer-in-charge. On the site when the contractor is in a
position to commence each portion of the work.

The trench shall be not less than 1/2 meter wide and 90 cms deep. If more, cables are to be
laid, the width should be suitably increased

ix. After the cables are laid, the trench shall be filled in layers, the earth in each layer
being well rammed by spraying water and consolidated and sufficient allowance
made for settlement. The extra earth over the trench should be removed from the
place of trench to a place as decided by the Engineer- in-charge at site.
x. Ends of cables shall be properly sealed to prevent entry of moisture prior to
installation.
xi. Where it is as specified as 1/2 core cables, the 1/2 core shall be a neutral
conductor having reduced section.
xii. For all multicore cables each core and tails shall be brought out, marked and or
coloured in on approved manner.
xiii. Cable termination shall be done with suitable compression brass glands in the
case of PVC cables and cast iron trifurcating boxes in the case of APLSTS

Signature of Contractor 240


cables. The armour should be connected to the right main earth in building with
duplicate earth wires as per the relevant IS/BS specifications.
The core insulation over each conductor shall however be retained through out
the run of the conductor upto the end where lugs shall be fitted thereon for
connections. The -lugs shall be fitted by means of approved solder and flux such
as a leap, and Eyre No. 7 liberally used. The joint shall be mechanically strong
and pressure tested.

2.6 DISTRIBUTION
BOARDS
AND PANELS:
General
Requirements:

2.6.1 All distribution panels shall comply with I.E.E. Rules 60-61. A clear distance of 0.91 b
meter in front of the switch board shall be kept. Where bare connections or attachments are
provided at the back of the switch board the space behind the panel shall be either less
than 0.299 meter or more than 0.762 main width there shall be a passage way from the
furtherest outstanding part of any attachment or conductor. If the space behind the switch
board exceeds 0.70 main width there shall be a passage way from either end of the switch
board clear to height of 1.928 m width 0- 299 m. All wiring connection shall be made neatly and
securely

2.6.2 For crocoites carrying more than 10 Amps, tinned cable sockets shall be used. All
connections shall be so made as to form their own diagram Circuit shall be clearly
numbered to correspond to wiring diagram Names of the distribution boards shall be painted as
directed by the Engineer-in-charge. All the switch fuse units and isolators D.Bs. shall be
complete with earthing studs lugs neutral bar link, H.R.C. fuses and of approved make.
2.6.3 Skeleton type panels shall have a rigid form work adequately braced and supported.
The switch and distribution boards shall be neatly arranged in the frame. The
details of the frame work and the arrangement of switches shall be got approved by
the Engineer-in-charge before the panel is fabricated.

2.6.4 All cubical type panels shall have rigid supporting frames adequately braced
over which sheet metal shall be nearly secured. All switches, distribution boards
etc. shall be neatly arranged on the panels and all connections made from the back of
switches. The panels shall be rendered dust and vermin-proof. The interior of the
panels shall not be accessible to unauthorized persons.
2.6.5 The recess type boards shall be embedded in wall in a cupboard with a
metal hinged door with locking arrangement. In all recessed conduit work all
distribution boards shall be recessed. Where recessing is not possible, free
standing panel may be provided as approved by the Engineer-in-charge.

1.6.6 All individual components i.e. switch fuse units D.Bs. etc. shall be connected by
earth continuity wire of appropriate size with the main earth bus of the panel D.B. etc.
The panel switches or D.Bs. shall be earthed by not less than 2 distinctive paths to
earth. Earthing of metallic parts or exposed metal shall not be effected through any
structural metal work which houses the installation. Where metallic parts are not
required to be earthed and are liable to become alive should the installation of the
Signature of Contractor 241
contractor become defective such metallic parts shall be separated by durable non-
conducting material from any structural work.

(a) Power panels shall be 3 phase, 4 wire, 400/230 volts for the distribution of 3
phase or single phase power loads. Lighting panels shall be 3 phase, 4 wire
400/230 - volts for single phase lighting load distribution
on all 3 phase.

(b) All panels shall be done or protected front type with no mechanical or electrical
defects.

(c) Bus bars shall be of electrolytic copper or aluminium as specified and the
properly tinned sizes as indicated on applicable drawings as required.

(d) All knock outs for branch circuits, conduit entries shall be drilled in and filled
as required. For lighting panels the top and bottom cover plates shall be
removable type.
(e) Main disconnect device for all panel boards shall be of switches of disconnect
type and of the size as indicated shall be mounted directly below the panel or
through a short thread conduit of required size.

(f) The main disconnect for all panel boards shall have an entry suitable for
PVC armoured cable from bottom.

(g) All panel boards shall be provided with an earthing terminal and lug for
connection to the grounding system.

(h) Temperature rise of all electrical parts shall not be more than 300°C with
full load amusers at ro om temperature.

(b) Buses shall be securely supported so that ordinary vibrations will not cause any
of the parts to become loose.
(j) All barriers and supports of current carrying parts shall be of moisture resistant
insulating material and shall not be adversely affected by arcing.

(k) The locations of panels shown in the drawings are only tentative. Panels
may be located at a place approved by the Engineer-in-charge

(I) All civil works connected with fixing such as grouting chasing and making good
shall be the tenderer's responsibility.
(m) Wires of adequate capacity with proper size of lugs shall be used for
interconnections.

(n) Panel should be self supported on angle channel iron frame work. It
should be preferably of bolted construction in case of transportation and
flexibility. The frames shall be of the required size for the mounting of
the equipment on it. It shall be bolted or grouted rigidly after leveling and
alignment.
Signature of Contractor 242
(o) The cupboard and D.B. should be of such size so to be accommodated in the
existing room as per I.S. rules and IS codes of practice for installations of
Medium Voltage switch gear.

(p) Fabrication drawing showing the detailed dimensions and panels and its
components indicating the frame work, earthing positioning of switches, D.Bs.
cable boxes, adopter chambers etc. shall be furnished to the Engineer-in-
charge for his approval. All material to be got approved by the Engineer-
in-charge. Panel should be guaranteed for satisfactory operations for a period
of one year after handing over.

(q) The panel should be painted with anticorrosive paint suitable for humid
and salty atmosphere on two coats of primer

Switch Gears, Powers Panels D.B. and S.F. Us.

2.6.8 The main busbar shall have continuous current rating as specified with neutral bar
having half of full load rating of the phase busbar. The sizes of the bus bars shall be so
selected that the current density in bar does not exceed 150 amps, per sq.m. for copper.
The length of bus-bar chamber should be as suitable length to fix all the switches etc. as per
the prevailing standards, clear spacing of two adjacent buses shall be 11/2" minimum bar
should be itapted all along with colour coated 11 KV grade PVC tape. The maximum internal of
support for each unsupported length shall exceed 600 mm.

The bus bar shall be of copper/alluminium and fabricated to the relevant


standards specification. In case alluminium bus bar is used special with high
conductivity alluminium bus bar alloy E 91 C frame conforming to E.S.S. 2898 shall
be used. The current density shall not exceed 800A per sq. inch. Hylam
barriers will be provided over the joints to prevent any short circuit.

The bus enclosing shall be made out not less than 16 gauge M.S. sheet construct on
with angle iron support. All interconnections between bus bars S.F. Us. and D.
Bs. shall be of adequate size and details of such inter connection shall be
furnished to the Engineer-in-charge for his approval.

The bus bar shall be air insulated extensible type rectangular one. The bus bars
chamber shall be dust tight by providing gaskets secured properly -so as to tender it
vermin proof.
The Combination Fuse-switch unit should comply with IS 4064 BS 861 and BBS 2510
wherever applicable. It should be suitable to accommodate High Rupturing Capacity
Cartridge Fuse links complying with IS 2208 or BS 88 and having a certified rupturing
capacity of not less than 35 MVA at 440 volts (ACS duly). The switch gear (panes.
D.Bs. etc.) shall be installed generally as per IS-Part- I 3072 and as specified and
shown in drawings

All fuse switch units shall be provided with non-deteriorating HRC fuse links complying
with IS 2208-1962 and having rupturing capacity of 35 MVA at 415 volts or as specified.

Signature of Contractor 243


All switches above 60 amps, rating shall be provided with suitable size adapted boxes.
All switches mounted on the top of the busbars shall be provided with detachable
type reverse entry adapter boxes. Suitably engraved lables shall be provided for each
circuit as well as for the board.

A meters sector switches and LMH metre shall be provided where specifically
mentioned. Small wiring for the inter-connecting shall be colour coded and provided with
numbered fuses for easy identification of circuits.
(a) The distribution boards should be totally enclosed metal clad complying with B.S.
214. The M.S. sheet steel enclosures for recessed D.Bs. shall be of not less than 14
gauge.

(b) The D.B. shall be with handed door and the locking arrangements as
approved by the Engineer-in- charge.

(c) All the components shall be enclosed in the enclosure. The mounting of D. B.
shall be got approved by the Engineer-in-charge before carrying out the
installation.

(d) The D.Bs. shall have proper size cut outs for conduits entry or cabbie entry as
required and these shall be made on site.

(e) Adequate spacing shall be provided inside the D. Bs. for easy removal of the
fuses and carry out the interconnection.

(f) A set of insulating barriers have to be provided between incoming breakers


switches and fuses.

Switch fuse Units:

(a) All the D.P.T.P and T.P.N. switch fuse units shall be totally enclosed iron clad
quick make, quick dreak type to best Indian make conforming to the I.S. or
B.S. 3185 specifications. All the switch fuse units shall have mechanical
interlock with a door, so that the door cannot be opened when the switches
are in 'ON' position, The switches should be of double break solution type to
ensure safely.

(b) Each T.P. & T.P.N. switch fuse unit shall be earthed with two distinct earch
connections.

(c) Suitable insulator shall be provided between phase.

(d) There shall be suitable natural link in the fuse box.

(e) All T. P. & T. P. N. switch fuse units shall be rated for 500 volts and D.
P. (required for single phase supply) and S.P.N. switches for 250 volts.

(f) The H.R.C. cartridge fuse shall conform to H.S. 88 (1952).

Signature of Contractor 244


The O.C.Bs., ACB shall be suitable for 400/440 volts 3 phase 50 cycle supply
capable of interrupting a fault MVA of not less than 31. The circuit
breaker shall conform to the BSS-936-1940 BSS 3659 with such tripping
arrangement as may be required under special specifications for the building.
Efficient and fool-proof mechanical interlocking shall be provided for the
safe operation and maintenance The rate shall be inclusive of the first filling
of oil.

2.7 Instrumentation:

The instruments and meters wherever necessary shall be housed in special


sheet steel box located between switch fuses units and bus bar chambers. The
instruments etc. shall be mounted on the hinged cover with heir dial flushed. All
instruments shall have protective H. R. C. fuse links. All interconnections and small
wiring shall be neatly dressed arranged and duly coloured for easy identification or
circuits.
Meters shall be provided as required in the Schedule, meters shall be dead head and be
suitable for 400/440 volt phase 4 wire 50 cycle (in balanced load) supply.

Each selector switch shall be 3 point and of minimum 250 volts grade with
silver tipped contacts suitable for metering circuits, current transformers shall be
of 5VA burden and commercial metering accuracy. Indicating lamps shall be penal
mounting type preferably of 250V grade. Every unit shall be prewired and
interconnected to the system for its required indicating performance. Indicating lamps
shall have independent circuit fuse.

2.8 FIXING OF LIGHTING FIXTURES:

1. Location of fixtures their manner of fixing mounting height etc. are indicated in
relevant drawing. Actual location and levels shall however be arrived at site in
co-ordination with other service etc and prior approval of the Engineer-in-
charge regarding the actual location. Manner of fixing shall be obtained before the
work is taken up in hand.

2. In all cases the contractor shall provide necessary interconnection wiring earthing
painting etc. all necessary for complete installation. The contractor shall also test and
commission the fixtures during
completion of the work.

3. General arrangement of fixtures layout is indicated in drawings. Care shall be taken to


see that all light fixtures are in a row in a room or particular area, are in absolute line
and plump and are symmetrically disposed with respect to finished surfaces of walls
columns beams etc,

4. The inter-connections wiring from the light outlet point upto the fixture shall be carried
out by means of flexible copper wire of section not less than 1.5 mm2.

5. All fixtures suspended by means of conduits shall be done with all and socket joints or
as per approved design.

Signature of Contractor 245


2.9. Telephone System:

1. Empty conducting shall be done, recessed or exposed to surface along with pull
boxes, junction boxes and telephone outlet boxes, in areas and location as indicated in
the relevant drawing as per materials and methods
as described in regard to conducting under section "Wiring in Conduits" except the
G.I. pull wires of gauge not less than 20 SWG shall be kept pulled through conduits in
all sections so that in future telephone wires can be pullet easily.

2. Location shown on the drawing are approximate and final location shall be decided in the
field by the Engineer-in-charge.

SECTION G

SPECIFICATION FOR EARTHING

1. Installation of Earthing Plates :

All installation of earthing shall conform to Indian Electricity Rules IS-3043 latest
edition and I.E.E. The copper earth plates should be tinned before installation. The
earth plates of copper 60 cm x 60 cm x 3.515 mm. thick size as mentioned in the
schedule be in separate pits at least 150 cms to 300 cms. away from the building at a
depth necessary to reach moist earth surface but with a minimum depth of 2.5 mtr
from the finished ground level
up to the top vertical dodge of earth electrode. The earth plate shall be thoroughly
cleaned to remove all dirt from the surface and be tinned property for electrical
contact with the main ground. Each earth pit should be provided with 38 mm. dia G. I.
pipe 2.5 Mts. long or more depending upon the depth of pit, put over the vertical
edge of earth plate (with top end of pipe provided with a closed to couyler).
Alternative layers of salt and coke shall be provided surrounding the plate. The pits
shall be filled when the plates are in position and with the approval of Engineer-in-
charge.

To facilitate watering the pit, a concrete compartment should be made with funnel with
mesh and cover plate as per rules provided in ISI regulation. The masonary endousures
shall be 25 cm x 25 cm x 25 cm (deep) with C. I. lid of 23 cm x 30 cms size. After
installation, the earthing resistance of each earth plate should be measured by resistance
meggar in the presence of Engineer-in- charge, three days after the completion of
earthing work, and the value should conform to regulations.
Signature of contractor/s
Executive Engineer
Division

Signature of Contractor 246


LIST OF MANDATORY TESTS

Signature of Contractor 247


LIST OF MANDATORY TEST

SR. MATERIAL TEST FIELD/ MINIMU FREQUENCY REFERE


NO. LABORATOR M OF TESTING NCE FOR
Y TEST QTY. OF IF QTY. IS TESTING
MATERIA BEYOND THE REQUIREM
L FOR MINIMUM ENTS
CARRYIN QUANTITY
G OUT
THE TEST

1 Sand Bulking of Field 20 Cum Every 20 cum As per CPWD


sand or part there of specification
or more
frequently as
decided by EIC.

Silt content Field 20 Cum Every 20 cum As per CPWD


or part there of specification
or more
frequently as
decided by EIC.

Particle size Field or 40 Cum Every 40 cum of As per CPWD


distribution Laboratory as fine aggregate / specification
decided by sand required in
the EIC. RCC work only.

Organic Field 20 Cum Every 20 cum As per CPWD


Impurities or part there of specification
or more
frequently as
decided by EIC.

2. Stone Percentage General visual As required For all IS : 2386,


Aggregate of soft or inspection, by EIC quantities Pt – II, 1963.
deleterious Field/laborato
materials ry test
wherever
required by
the EIC or as
specified
Particle size Field or 45 Cum For every 45 As per CPWD
distribution Laboratory as Cum or part specification.
required by thereof for RCC
EIC Work only. For
rest of items as
decided by EIC.
Signature of Contractor 248
Organic Field/ 10 Cum For every 40 IS : 2386,
Impurities Laboratory Cum or part Pt – II
thereof
Surface Field/ 10 Cum For every 40 IS : 2386
Moisture Laboratory Cum or part
thereof
Ten percent Field/ 10 Cum For every 40 IS : 2386
fine value. Laboratory Cum or part
thereof

Specific Field/ 10 Cum For every 40 IS : 2386


Gravity Laboratory Cum or part
thereof

Bulk Density Field/ 10 Cum For every 40 IS : 2386


Laboratory Cum or part
thereof

Aggregate Field/ 10 Cum For every 40 IS : 2386


Crushing Laboratory Cum or part
Strength thereof

Aggregate Field/ 10 Cum For every 40 IS : 2386


Impact Value Laboratory Cum or part
thereof

3. Cement (OPC) a)Physical Every 50


requirement Tonnes or part
thereof. Each
-Fineness Laboratory Each lot brand of IS : 4031
cement brought ( Part-II)
-Soundness to site shall be IS : 4031
tested as per ( Part-III)
-Setting Time this frequency. IS : 4031
(Initial & ( Part-V)
Final)

-Compressive IS : 4031
Strength ( Part-VI)

-Consistency
of Standard IS : 4031
Cement ( Part-VI)
paste

4. Steel for I. Tensile Laboratory 20 M.T. For For IS: 1608-


reinforced Strength consig consig 1972
Signature of Contractor 249
concrete II. Bend test Laboratory nment nment IS:1599-
III. Weight Field/Lab below over 1985
100 100
tonnes tonnes

*Unde *Unde
r 10 r 10
mm mm
dia. dia.
One One
sampl sampl
e for e for
each each
25 40
tonnes tonnes
or part or part
thereo thereo
f. f.

*10 *10
mm to mm to
16mm 16mm
dia. dia.
One One
sampl sampl
e for e for
each each
35 45
tonne tonne
or part or part
thereo thereo
f. f.

*Over *Over
16mm 16mm
dia. dia.
One One
sampl sampl
e for e for
each each
45 50
tonne tonne
or part or part
thereo thereo
f. f.

5. a) Water for I. Chemical Laboratory From each Before IS-3025-


construction Properties source commencement 1986 or
purposes of work and latest
i) pH Value -do- thereafter every

Signature of Contractor 250


ii) Limits of -do- three months
Acidity till completion
iii) Limits of -do- of work. Water
Alkality from municipal
source need to
be tested only
II. Physical Laboratory once in six
months.
Properties Number of tests
for each source
iv) shall be 3
Percentage
of Solids like
Chlorides,
Suspended
matter,
Sulphates,
Inorganic
solids,
Organic
solids

b) Water for - do - Laboratory From each As decided by IS:10500-


potability source EIC. 1991

6. Cement I. Slump Test Field 10 Cum 15 Cum of part As per CPWD


concrete thereof or more specification
frequently as
required by EIC

7. Reinforced I. Slump Test Field 5 Cum in Every 5 cum or IS : 516-


cement /Laboratory case of part thereof 1956 &
concrete. columns. CPWD
a) Nominal mix specification.
20 Cum for Every 20 cum
slabs, or part thereof
beams &
connected
columns
Every 20 cum
20 Cum for or part thereof
other RCC
work for all
other small
items and
where RCC
done in a
day is less
than 5 Cum
test may

Signature of Contractor 251


be carried
out as
required by
E.I.C.

II. Cube Test Laboratory - Do- - Do- - Do-

8. Reinforced
cement
concrete.
b) Design Mix

Coarse 50 Cum or
Aggregates part
thereof &
also on
each
change of
source

Fine 50 Cum or
Aggregates part
thereof &
also on
each
change of
source

Cement 50 MT or
on each
change of
source

Fresh Concrete I. Slump Test Field 10 Cum 50 Cum for IS : 456 –


R.C.C. work 2000 &
including in all CPWD
other small specification.
locations.
R.C.C. done in a
day is less than
50 Cum test
may be carried
out as required
by E.I.C.

Fresh Concrete II. Cube Test Field 10 Cum or 50 Cum or 10 IS : 456 –


part batches of 5-7 2000 &
thereof. cum each for CPWD
R.C.C. work in specification.
Signature of Contractor 252
all locations
taken together.
R.C.C. done in a
day is less than
50 Cum test
may be carried
out as required
by E.I.C.

III. Hammer Field -do- Once in three As per CPWD


test months or as specification
directed by the
EIC.

9. Reinforced
cement
concrete.
c) Ready mix
concrete

Coarse 50 Cum or
Aggregates part
thereof &
also on
each
change of
source

Fine 50 Cum or
Aggregates part
thereof &
also on
each
change of
source

Cement 50 MT or
on each
change of
source

Fresh Concrete I. Slump Test Field / 10 Cum 50 Cum for IS : 456 –


Laboratory R.C.C. work 2000 &
including in all CPWD
other small specification.
locations.
R.C.C. done in a
day is less than
50 Cum test
Signature of Contractor 253
may be carried
out as required
by E.I.C.

Fresh Concrete II. Cube Test Laboratory 10 Cum or 50 Cum or 10 IS : 456 –


part batches of 5-7 2000 &
thereof. cum each for CPWD
R.C.C. work in specification.
all locations
taken together.
R.C.C. done in a
day is less than
50 Cum test
may be carried
out as required
by E.I.C.

10. Bricks / Bricks Testing of Laboratory 20,000 Nos As peer CPWD IS : 3495-
Tiles / Fly ash Bricks / Brick specifications 1976
bricks Tiles for
dimensions,
compressive
strength,
water
absorption
and
efflorescence

11. Timber I. moisture Field (by 1 Cum Every one Cum IS: 287-1973
content moisture or part thereof. &
II. Bulk meter) or IS:1003 –
Density laboratory 1004
III.Species test as
required by
EIC

12. Flush door I. End Laboratory 26 shutters As per CPWD IS : 2202 –


Immersion specifications 1991
Test (Part I & II)
II..Knife Test
III. Adhesion
Test

13. Aluminium Thickness of Laboratory If the cost Rs. 20,000.00 IS : 5523-


door and anaodic of fittings or part thereof 1969
window fittings coating. exceed Rs. as required by
20,000.00 EIC.
14. Mortice Locks Testing of Laboratory 50 Nos. 100 or part IS : 2209-
spring thereof 1976

Signature of Contractor 254


15. Terrazo Tiles I. Laboratory 5000 nos. One test for IS : 1237-
Transverse (No testing every 10,000 1980
Strength need be nos. Or part
II. Water done if thereof for each
total type and size
Absorption number of from a single
III. Abrasion tiles of all manufacture.
Test types of all ( One test to be
Sizes from done even if the
all M/g. number of
Used in a terrazzo tiles of
work if less any type and
than 5000 size from a
nos. single
manufacturers
is less than
5000Nos.
provided the
total number of
terrazzo tiles of
all types and
sizes from all
manufactures
used in work
exceed 5000
Nos.

16. White Glazed I. Water Laboratory 3000 nos. 3000 nos. Or IS : 777-
Tiles / Ceramic Absorption part thereof 1988
Tiles (for floor II. Crazing Laboratory IS. 13630
and wall). test Laboratory
III. Impact
Strength Laboratory
IV. Chemical
Test
V.
Dimension
s&
surface
quality

17. Aluminium Thickness of Laboratory 250 Kgs. 250 Kgs or part IS : 5523-
Sections for powder thereof 1969
Doors and coating or
Windows thickness of
anodising.

Signature of Contractor 255


18. Marble I. Moisture Laboratory 50 Sqm. 100 Sqm. or IS: 1124-
Absorption part thereof 1974

II. Hardness Laboratory


Test Mho‟s scale

III. Specific Laboratory IS: 1122


Gravity.

19. Granite I. Moisture Laboratory IS: 1124

II. Specific Laboratory IS : 1122


Gravity

20. Commercial I. Thickness Field 100 Sq.m 100 Sqm or IS : 1659-


Board/Block test Laboratory part thereof 1590
board II.Dimension
al Laboratory
Test
III.Resistanc Laboratory
e
to Water.
IV. Adhesion
of Piles.

21. Plywood I. Thickness Field 100 Sqm 100 Sqm or IS : 303 –


test Laboratory part thereof 1989
II.Glue
strength Laboratory
(in dry
state)
III. Glue
sheer Laboratory
Strength
(in
water

resistance
state)
IV. Moisture
Content.

22. Particle Board I. Thickness Field 100 sqm -do- IS: 3087-
test 1985
(plain)

II.Physical IS: 3097-


and 1980
(Veneered
Mechanical
Signature of Contractor 256
Properties
23. Gypsum Board I. Thickness Field / 100 Sqm. 100 sqm. Or IS:2095-
test Laboratory part thereof 1976
II.Transverse
Strength

24. Steel Tubular a. Tensil Laboratory Every 8 Every 8 Tonne IS: 1608
Pipes e test Tonne or or part thereof. IS: 2329
b. Bend part IS :2328
test thereof.
c. Flattening
test

Signature of Contractor 257


LIST OF APPROVED MAKES

SCHEDULE

OF

APPROVED MAKES / MANUFACTURER'S OF MATERIALS

The following guidelines are to be noted with regard to use of materials in the work :

1.00 As far as possible, materials bearing "Standard Mark (ISI)" from Bureau of Indian
Standard(BIS) shall be used in the work.

2.00 Wherever, materials bearing Standard Mark (ISI) are used in the work, the following
shall be ensured :

2.1 The supplier has a valid license form BIS during the period the material is being
used in the work.

2.2 The Contractor should maintain furnish necessary documents and proof of
payments made for the procurement of materials bearing Standard Mark (ISI).

3.00 Due to non-availability of materials, bearing ISI Mark as detailed in Para-2 above the
materials as per the list of approved makes of materials shall be used in the work and
the Contractor shall be free to use any of makes given in the attached Annexure.

Signature of Contractor 258


4.00 In case, it is established that standard material (bearing ISI Mark) as well as the
materials indicated in the list (as mentioned in the above para) are not available in the
market then approved equivalent materials may be used in the work subject to approval
from the consultant and Engineer-in-Charge.

5.00 Mandatory Tests shall be conducted at the specified frequency specified in the Contract.
In case, frequency of testing is not stipulated in the contract then standard specification
(R&B,CPWD,ISI etc.) may be considered for frequency at which materials are to be
tested.

6.00 Before bulk purchase of quantities of materials, it is the responsibility of the Contractor
to get the samples of materials approved from consultant and EIC.

7.00 All cost towards the testing shall be borne by the contractor.

LIST OF MAKES FOR


CERTAIN MATERIALS ACCORDING TO WHICH THE MATERIALS TO BE PROVIDED

1. Ordinary Portland Cement Ambuja, Ultratech, Sanghi, ACC, JK, Vikram, Birla Cement,
Binani

2. White Cement J.K. White, Birla White, Nihon White

3. Reinforcement Bar TATA, SAIL,Thermax, Vizag, Sanghi, Jindal or equivalent

4. Structural Steel SAIL,TISCO, ISCO, Vizag

5. Teak Wood Bulsar/ C.P Teak (Second Class specified)

6. Kota Stone / Marble / As per approved sample


Granite / Jaisalmer Stone /
Red Agra stone/ Dholpur
stone

7. Ceramic Tilles Bell Ceramics, Somani, Kajaria, Nitco, Cera, Johnson, Asian,
( White, Colored, Anti Euro, Restiles
Skid)
Signature of Contractor 259
8. Vitrified Tilles Bell Ceramics, Somani, Kajaria, Nitco, Cera, Johnson, Asian,
( White, Colored, Anti Euro, Restiles, Granamite
Skid)

9. Chequered Cement Tiles / Nitco, NTC, Kajaria, Vyara


Decorative Tiles

10. White Glazed Tiles „H & R Johnson‟, „Somani Pilkington‟, Nitco, Cera, Bell,
Kajaria, Asian, Euro

11. Interlocking paver blocks Regency, Gurjari, Vyara, PEEDEE, Jagruti – Surat
or as approved by EIC/consultant

12. Plywood Products Greenply, Novopan ,/Sitapur Plywood/ Kitply /Century,


Commercial Block Board Anchor, Duro, National wood craft, Alpro, Neolux Laminated,
Commercial Ply Teak Ply Formica, Decoboard, Sunmica Board/Bhutan, Green Ply,
Western India plywood (WIP). M.P., Mysore marine.

13. Laminates / Decorative Decolam, Greenlam Merinolam Formica, National laminate,


laminates Neoluxe, Decolite, Delta.

14. Pre laminated board Bhutan, Novapan, Eco board, Bakelite Hylem Nepal board,
Green board.

15. Impregnated Fibre Board Shalitex by Shalimar Tar Product.

16. Teak Veneer Anchor, Kitply or equivalent

17. Flush Doors „Sitapur plywood‟, „Mysoboard‟, Sudarshan W & P Industries,


Bajwa, Baroda, Goyal, industrial corp, Wood craft, Jain wood
industries, Alpro, Genda- Northen Doors, Greenply, Kitply,
Bhutan.

18. Aluminium Section Indal, Hindal, Jindal, Ajit, Banco, Gujarat Extrusion, Hindalco,
Mon, Domal

19. All Aluminium Hardware, Everite, Garnish, Arches, Kausal, Nulite Alif, Shalimar
Fittings (Bombay) Singla, Opel, Bolt, Arhish

20. Aluminium Doors, As approved by EIC/Consultant


Windows, Partitions
Fabricators

21. Stainless Steel Hardwares Kitch, Dorma or other approved makes


Fittings

22. Glass/Float/Sheet Saint Gobain, Modi, Hindustan Pilkington , Hindustan , Tata ,


Asahi, Triveni, Shree Vallabh
Signature of Contractor 260
23. Door Closer / Floor Godrej / Everite, Opel, Doorking/ Hardwin, Nulite, Hyper,
Spring Ezec,

24. Locks Godrej, Harrison, Plaza, Golden, Doorset

25. Friction Hinges Imax, EBCO

26. Polysulphide Sealant For Chokesy Chemical, Structure Proofing Co Pidilite, GESilicon,
Expansion Joints All Tuffseal
Windows

27. Synthetic Enamel Paints / Shalimar‟, ICI‟, „Goodlass Nerolac‟, , Berger, Johnson &
Oil bound distemper Nicholson, Asian Paint, Dulux

28. Water Proof Acrylic Paints / „Super Snowcem‟, Supercem, Asian, Nerolac, Berger, Dulux
Weather proof Acrylic
Paints

29. Plastic Emulsion paint J & N, ICI, Asian, Berger, Dulux

30. Dry Distemper / Oil Bound Shalimar‟, ICI‟, „Goodlass Nerolac‟, , Berger, Johnson &
Distemper Nicholson, Asian Paint, Dulux

31. Duco Spray Paint ICI or equivalent

32. Polyurethane Paint MRF or equivalent

33. Melamine spray polish Asian paints , Nerolac or equivalent

34. Wood polish Asian paints , Nerolac , Nebula chemicals (Acrypoll) or


equivalent

35. Water Proofing Compound „ CICO‟ , Fosroc, GE ilicon Pidilite, MC-Bauchmie, Sika

36. Weather Sealent / Silicon Fosroc, Pidilite, MC-Bauchmie, Wecker 789, Dow corning 789
sealent / Poly isobutylene or equivalent
sealent

37. Hardeners „Ironite‟, „Ferrok‟, „Hardonate‟.

38. Wire Mesh Sterling Enterprises, Trimurti, Welded Mesh.

39. Anti-Termite Treatment Thyodin by Hoechest, Lyntric by Bayer India, Durmet by


Cynamid India, Nocil Pyramid

40. M.S. Tubes TATA, SAIL, Vizag, Jindal or equivalent

41. Welding Rod Advani, Philips, Sunarc, Eshab

Signature of Contractor 261


42. Fly ash Bricks As approved by EIC / Consultant

43. Construction Chemicals Fosroc, MC-Bauchmie, Sika, Pidilite

44 Lift Otis, Kone, Thyssen Krupp

45 Cast Iron Pipes and TISCO / ISCO/ KESHO SPUN Co. - Calcutta E.L.C. Standard
Fittings approved manufacturers of any other brand of fittings having
(LA Class) ISI marking.)

46 R.C.C. Pipes Indian Hume Pipe Co., Alcock Cement Products,Patel Spun
(Surat)

47 G.I. Pipes Jindal, Prakash, Surya, Gujarat Steel Tube, Tata, Bharat Steel
Tube, Bombay, Zenith, G.S.T.Unik.
48 G.I. Fittings " R " Mark, Unik.

49 Gun Metal Valves Leader Engineering Works, Jallandhar, Crown / prince - Surat
Bombay Metal Co Annapurna Metal Work, Calcutta'Sant'
brand, Jallandhar, L&K, Bombay metal & Alloy man. co.
Bomaby, Premier,Aatco,Atlas,BR,BS,NN.

50 Brass fittings Leader Engineering Works, Calcutta L & K Mathura, Crown /


Prince -Surat Annapurna Metal Works, Calcutta, Perko,
Kingstone Ark, Enclss Willians, Chilly, Aquva
Plus,Nova,Kingstone,Driple, Ranutrol Hansa.

51 C.P. Fittings Ego Metal Works, Ballabhgarh,; GEM, New Delhi; Soma
Calcutta; Bilmet, Bombay 'ESSCO', Delhi. Rajka Metal Works,
Delhi Eng. Co. Metal Works, Calcutta Everite, NU-Lite
Navbhart Shalimar Crown, Prince

52 W.C. Pan / Wash basin / CERA, E.I.D. Parry, Hindware , Neycer, Johnson
Urinals / flushing cistern

53 Flushing Cistern -Cast iron Overhead - 'Nomos' 'ELCO' 'A-1'AUTOMATIC-EID Hindustan


Sanitaryware, Calcutta, Nelson flush valve, SRIF(Agara),
Parrys -Madras

54 E.W.C. Seats (solid) E.I.D. Parry, Hindware, CERA, Neycer, Hindustan

55 Stainless Steel Sinks Nirali, Diamond, Nilkanth, Cobra, AMC, Jayna

56 Mirrors Atul Glass Works , Haryana Sheet Glass Vallabh Glass Works,
Modi Float glass, Asahi, Saint Gobin

57 Plumbing / Sanitary Jaquar continental , CERA, Hindustan Sanitaryware /


Fixtures / Accessories Parryco India.
Hindware, Lauvet, Kohlar, Rak, Jaquar
Signature of Contractor 262
58 C.I. Manhole cover with ISI approved make
frame

59 P.V.C. Pipes & Fittings Supreme, Prince, Finolex, Laxmi, Prakash, Jain

60 P.V.C. / H.D.P.E Water Sintex, Purvee, Renu or equivalent


Tanks

61 Ball Cock GPA Brand by Govardhan Das Jullunder, L & K Brand by L. K.


Industries Mathura, Sant Brand by Sant Press Metal Works
Jullundhar

62 Fire Hydrant Valve & Air ISI approved make


Valve, Scour Valve

63 Fire fighting equipments ISI approved make, Safe time services-Surat

64 Rolling Shutters 'Standard', 'Swastik', 'Diana', 'Hercules', As per approved


fabricator.

65 Gypsum Board False Indian Gysum or equi.


Ceiling

66 Pre coated Sheets Tata Blue scope, Multicolor steels, Interarch, Kirby, Tiger
steel

67 Thermal Insulation Twiga, Multicolor steels

68 Polyester Fibre Recron 3S or equi.

* Notes :

a) The contractor shall produce samples of the materials for approval of the EIC.
The materials of the makes out of the above as approved by the EIC shall be
used on the work.

b) In respect of materials for which approved makes are not specified above, these
will be of makes to be decided by the EIC.

Signature of Contractor 263


-- List of Approved Products for Electrical Works--

WIRING Anchor Elect. P.Ltd.


Marathon lnnova C Wing.
1.1 SHOCKPROOF ACCESSORIES Opp.G.K.Marg, Lower Parel [ W ]
Mumbai
(A) Concealed / Surface Type
Any I.S.I. marked switches and 2.POINTER
accessories approved by the H.O.B-15,Atlanta
Engineer-in-charge of work. Evershine,Evershine
Nager,Malad [ W ].Mumbai-
(B) Mini Modular Type (Approved ) 400064

1. ANCHOR (C) Modular Type

Signature of Contractor 264


2. ANCHOR-ROMA / WOODS
A. CATEGORY-I M/s Anchor Electrical
P.L.Marathon lnnova, C-
1. PRECISION Wing,Opp,Peninsula Corporate
M/s Precision Electrical Shiv Park, Of.G.K.Marg,Lower
Sager estate, Parel (W) MUMBAI-400013
A-Block (Basement) Dr.A.B.Road
Worli, 3. POINTER-SPECTRA
Mumbai -400018 M/s PRISM INDUSTRIES, H.O. B-
2. ANCHOR - RIDER 15,
Anchor Elect.P.Ltd Atlanta Evaershine Nager,Malad
Marathon lnnova C Wing, (W)
Opp.Penivisula Corporate Park, Mumbai-400064
Opp.G.K.Marg,Lower Parel [W]
MUMBAI 4. ELLYS
3. POINTER-ITALIA M/s ELLE Electrical P.L.,Cama industrial
M/s PRISM INDUSTRIES H.O.B- Area,Walbhat Road,NEXT to Rajaram
15,Atlanta Tarphe, Goregaon (E), Mumbai -400063
Evershine Nager Malad (W)
Mumbai-400064 5. HI-FI
4. ALEX M/s Aerolite industries.5 Sall industrial
M/s Alex lndustires, 3,Neminath Eastate
industrial l.B.Road,Goregaon (E), Mumbai-4000
Estate no.3 Navghar road,Vasai
[E] Dist. 6. WONDER
Thane -401210 [EVER/PLAYBOY/COLLICY/DASH
5. ORPAT GOLD/FORTNUNE]
M/s. Ajanta industrial M/s Wonder industries, G-14,O.I.D.C.
Estate,Rajkot Udhyog
Highway Post Box No.115, Nager industrial Estate,GIDC,
Morbi Ringanwada, DAMAN
6. SAFECON‟S (U.T )
M/s KALA ELECTRICAL
INDUSTRIES, 7. ALLWYN
12/A,Eagal Market,90 Feet M/s ALLWYN ELECTRICAL
Road,Saki INDUSTRIES,78,
Naka,Mumbai-400072 Kakad industrial Eastate,Lady
7. S.G. Jamshedji road,
Mahim,Mumbai-400016

B. CATEGORY-II 8. INDOASIAN
M/s indo Asain Fusegear Limited, 203-
1. SALZER 204,
M/s SALZER EKECTRONICS Shreedhar Avenue, 11, Sardar Patel
LTD, Colony, Nr.
Samichettipalayam,Coimbatore- Sardar Patel Statue, Naranpura,
641047 Ahmedabad.
9. GELCO

Signature of Contractor 265


13. C&S GEWISS
M/S. GELCO ELECTRONICS P.L., 6,7,8 &16, M/s. Control & Switchgears Contractors
Amarnath Estate, Nr. Krishna Gopal Estate, Ltd.,
Naroda Road, Ahmedabad. 9th Floor, HERITAGE, Nr. Gujarat
Vidyapith, Ashram
10. ABB Road, Ahmedabad-380 009.

M/S ABB Limited, 2nd Floor, Est Wing, 14. MK


Khanija Bhavan, 49, Race, Course Road, 15. LK
Banglore – 560001. L.K. Switchges, 165, GIDC, Makarpura,
Baroda-
11. VINAY 390001.

M/s. Vinay Electricals, 18-A, Singh


Industrial Estate, Bldg. No. 1, Rammandir 16. NORTHWEST
Road, Gorengaon (W), Mumbai- North West Switchgear Ltd., 14/3, Mathura
40014. Road, Faridabad, Haryana – 121003.

12. LEADER C. CATEGORY – III

M/s. Leader Electrical P.L., Leader House, 9- 1. HAVELL‟S-CRABTREE


B, Mahal Industrial Estate, P.B.No. 9483, M/s. Havell‟s India Ltd., 202-205, SHIVALIK
Mahakali Caves Road, Andheri (E), II, Nr. Shivranjani Cross Road, Satelite 132
Mumbai-400 093. Ft. Ring Road, Ahmedabad-380015.

1.2 RIGID PVC PIPES/OVAL PIPES & M/s. VRAJ PLASTIC INDUSTRIES,
FITTINGS 41, 42 & 43, Amarnath Estate, Nr.
Gokulesh Petroleum, Narol Cross
FIA Approved & ISI marked Road, Ahmedabad – 382405.
(Emossed) 5. VINAY
M/s. Vinay Electricals, 18-A, Singh
1. PRECISION Industrial Estate, Bldg. No. 1,
M/s Precision Electrical Shiv Sager Rammandir Road, Gorengaon (W),
estate, Mumbai-40014.
A-Block (Basement) Dr.A.B.Road
Worli, 6. POLYCAB
Mumbai -400018 M/s. Polycab Wires Pvt. Ltd., HICO
2. NIHIR House, 1st Floor, 771, Pandit
M/s. NIHIR POLYMERS INDUSTRIES, Satwalekar Marg, Mahim (W),
62, Umed Part Society, Sola Road, Mumbai-400016.
Ghatlodia, Ahmedababd – 380061. 7. SHRINATH
3. AMIT 8. BPL
M/s. Amit Electro Plast, 105, 1st M/s. Bhaglaxmi Plastic Industries,
Floor, Sarvoday Comm. Centre, 32, Asharva Ind. Estate, Opp.
Salapose Road, Nr. G.P.O. Khodiyar Estate, Narol, Ahmedabad.
Ahmedabad – 380001.
4. VRAJ

Signature of Contractor 266


1.3 OVAL /CASING & CAPING & PVC
TRUNKING LAMPS & FITTINGS

1. PRECISION 2.1 FIAMENT LAMPS/ FLOURESCENT


M/s Precision Electrical Shiv Sager TUBES
estate,
A-Block (Basement) Dr.A.B.Road (A) CAT-I
Worli,
Mumbai -400018 ANY ISI MARKED
2. NIHIR
M/s. NIHIR POLYMERS INDUSTRIES, (B) CATEGORY-II
62, Umed Part Society, Sola Road,
Ghatlodia, Ahmedababd – 380061. 1. ARYA
3. AMIT M/s. Arya Filaments P.L., 344,
M/s. Amit Electro Plast, 105, 1st Vishnupuri Annex, A.B.Road, Indore-
Floor, Sarvoday Comm. Centre, 452001.
Salapose Road, Nr. G.P.O. 2. GE
Ahmedabad – 380001. M/s. GE India Industrial Pvt. Ltd.,
4. VINAY 405, “Kirtiman”, Kinariwala House,
M/s. Vinay Electricals, 18-A, Singh B/H Citibank, Off. C.G.Road,
Industrial Estate, Bldg. No. 1, Ahmedabad-380009.
Rammandir Road, Gorengaon (W), 3. BAJAJ
Mumbai-40014. M/s. Bajaj Electricals Limited, 106,
5. POLYCAB 1st Floor, Sakar-III, Nr. Ashram
M/s. Polycab Wires Pvt. Ltd., HICO Road, Navrangpura, Ahmedabad-
House, 1st Floor, 771, Pandit 380014.
Satwalekar Marg, Mahim (W), 4. OSRAM
Mumbai-400016. M/s. Osram India P. L., Delhi Road,
6. SHRINATH Sonipat, Haryana-131001.
7. M.K.
(C) Category–II
DOUBLE WALL CORRUGATED PIPE NON
THREADABLE COMMUNICATION & 1. SURYA
ELECT.INST. CONDUIT PIPES [NON M/s. Surya Roshni Ltd. (Lighting
SOR] Division)
308, Shetali Centre, Nr. Paldi Char
Rasta, Ahmedabad-380006.
2. PHILIPS
1. REX M/s. Philips Electronics India Ltd., 7,
M/s. REX POLYEXTRUSION LTD., Justice Chandra Madhab Road,
Kumar Plaza, 1st Floor, 1077, North Kolkata-700020.
Shivajinagar, Opp. K.W.C. College, 3. CROMPTON
Sangli-416416. M/s. Crompton Greeves, C.Q. Hube,
2. DURA-GUARD 6th Floor, Dr. Annie Besant Road,
M/s. DURA LINE INDIA PVT. LTD., Worli, Mumbai – 400030.
Plot No. 24-25, Verna Electronics
City, Phase-IIA, Verna Salcete, GOA- 2.2 MERCURY VAPOUR LAMPS
403722 (North Goa).

Signature of Contractor 267


(A) CAT-I M/s. Crompton Greeves, C.Q. Hube,
6th Floor, Dr. Annie Besant Road,
ANY ISI MARKED Worli, Mumbai – 400030.
3. SURYA
(B) CATEGORY-II M/s. Surya Roshni Ltd. (Lighting
Division)
1. ARYA 308, Shetali Centre, Nr. Paldi Char
M/s. Arya Filaments P.L., 344, Rasta, Ahmedabad-380006.
Vishnupuri Annex, A.B.Road, Indore-
452001. 2.3 SODIUM WAPOUR LAMPS
2. SHAKTI
M/s. Shakti Fixture Industries, (A) CATEGORY-I
212/B, Bombay Talkies Compound ANY ISI MARKED
Malad (W), Mumbai-400064. (B) CATEGORY-II
3. ANCHOR
Anchor Elect. P.Ltd. 1. ARYA
Marathon lnnova C Wing. M/s. Arya Filaments P.L., 344,
Opp.G.K.Marg, Lower Parel [ W ] Vishnupuri Annex, A.B.Road, Indore-
Mumbai. 452001.
4. C&S GEWISS 2. SHAKTI
M/s. Control & Switchgears M/s. Shakti Fixture Industries,
Contractors Ltd., 212/B, Bombay Talkies Compound
9th Floor, HERITAGE, Nr. Gujarat Malad (W), Mumbai-400064.
Vidyapith, Ashram Road, 3. ANCHOR
Ahmedabad-380 009. Anchor Elect. P.Ltd.
5. GE Marathon lnnova C Wing.
M/s. GE India Industrial Pvt. Ltd., Opp.G.K.Marg, Lower Parel [ W ]
405, “Kirtiman”, Kinariwala House, Mumbai.
B/H Citibank, Off. C.G.Road, 4. C&S GEWISS
Ahmedabad-380009. M/s. Control & Switchgears
6. BAJAJ Contractors Ltd.,
M/s. Bajaj Electricals Limited, 106, 9th Floor, HERITAGE, Nr. Gujarat
1st Floor, Sakar-III, Nr. Ashram Vidyapith, Ashram Road,
Road, Navrangpura, Ahmedabad- Ahmedabad-380 009.
380014 5. GE
7. OSRAM M/s. GE India Industrial Pvt. Ltd.,
M/s. Osram India P. L., Delhi Road, 405, “Kirtiman”, Kinariwala House,
Sonipat, Haryana-131001. B/H Citibank, Off. C.G.Road,
Ahmedabad-380009.
(C ) CATEGORY – III 6. BAJAJ
M/s. Bajaj Electricals Limited, 106,
1. PHILIPS 1st Floor, Sakar-III, Nr. Ashram
M/s. Philips Electronics India Ltd., 7, Road, Navrangpura, Ahmedabad-
Justice Chandra Madhab Road, 380014
Kolkata-700020. 7. OSRAM
2. CROMPTON M/s. Osram India P. L., Delhi Road,
Sonipat, Haryana-131001.

Signature of Contractor 268


M/s Havell‟s india Ltd,
202-205,SHIVALIK II, Nr.
(C ) CATEGORY – III Shiveranjani
1. SURYA Cross Road, Satelite 132 Ft.Ring
M/s. Surya Roshni Ltd. (Lighting Road,
Division) Ahmedabed – 380015.
308, Shetali Centre, Nr. Paldi Char
Rasta, Ahmedabad-380006. 2 . SURYA
2. GE M/s Surya Roshni Ltd,(Lighting
M/s. GE India Industrial Pvt. Ltd., Division)
405, “Kirtiman”, Kinariwala House, 308,Shefali Centre, Nr. Paldi Char
B/H Citibank, Off. C.G.Road, Rasta
Ahmedabad-380009. Ahmedabad - 380006
3. PHILIPS
M/s. Philips Electronics India Ltd., 7, 3 . PHILIPS
Justice Chandra Madhab Road, M/s. Philips Electronics india Ltd, 7,
Kolkata-700020. Justice Chandra Madhab Road,
4. CROMPTON Kolkata-
M/s. Crompton Greeves, C.Q. Hube, 700020
6th Floor, Dr. Annie Besant Road,
Worli, Mumbai – 400030. 4 . CROMPTON
M/s. Crompton Greeves,
2.4 COMPACT FLOURESCENT LAMPS C.Q.Hube,6th
(A) CATEGORY-I Floor. Dr.Annie Besant Road, Worli,
1. ANCHOR Mumbai – 400030
Anchor Elect. P.Ltd.
Marathon lnnova C Wing. 2.5 METAL HALIDELAMPS
Opp.G.K.Marg, Lower Parel [ W
], Mumbai. (A) CATEGORY – I
(B) CATEGORY-II ANY ISI MARKED
1. SPANCO (B) CATEGORY – II
M/S Spance Semiconductors, 1. ARYA
10/11, Bhagat industrial Estate M/s.Arya Filaments P.L.344,
Nr.18No.ESI Hospital, Jay Bharat Vishnupuri
Rangshala Compound, Saraspur,, Annex. A.B.Road, indore – 452001
Ahmedabad – 380018
2. SHAKTI
2. GRE M/s Shakti Fixture industries 212/B,
M/s. GRE Electronics, Bombay Talkies Compound Malad
Plot No.423, G.I.D.C.-11,Dediyasan (W)
Mehsan – 384002 Mumbai – 400064

3. OSRAM 3. ANCHOR
M/s Osram india P.L.Delhi M/s Anchor Electrical P.L.Marathon
Road,Sonipat- Haryana – 131001 lnnova,C- Wing, Opp. Peninsula
Corporate Park, Of.G.K.Marg,Lower
(C) CATEGORY - III Parel (W), Mumbai-400013
1. HAVELL‟S

Signature of Contractor 269


4. C&S GEWISS
M/s.Control & Switchgers Contactors 1. GLOMORE-APPROVED
Ltd M/s Devraj Enterprises (P)
9th Floor, HERITAGE,Nr.Gujarat Ltd,401, Sobhna Appartment,
Vidyapith,Ashram Road,Ahmedabad- 4th Floor,Above Mandavi Bank,
380009 Chandravarkar Road,
Borivali [W]
5. BAJAJ Mumbai – 400092
M/s Bajaj Electricals Limited.106, 1st
Fl. 2. SHAH
Sakar – III, Nr.Ashram Road M/s Shah Electronics,
Navrangpura, Ahmedabad -380014 A-3,Manoharvila, New Naroad,
Nicol Road,Nr.Naroda Canal,
6. OSRAM Nicol,Ahmedabad – 382330
M/s Osram india P.L. Delhi Road,
Sonipat- Haryana – 131001
3. PULSE
(C) CATEGORY – III M/s Pulse Electronics &
1. SURYA Control,B/1,
M/s Surya Roshni Ltd, (Lighting Maruti Tenament,Opp.Shriji Bapa
Division)308, Shefali Centre, Complex , Nr.Rabari Colony,
Nr.Paldi Vastral to Odhav Canal Road,
Char Rasta, Ahmedabad-380006 Ahmedabad

2. GE 4. INAVA
M/s GE india industrial Pvt. Ltd., M/s lnava instruments
405, “Kirtiman”,Kinariwala House, international
B/H Citibank, Off. C.G.Road, 94,Ratnajyot ind. Estate lrla Lane,
Ahmedabad – 09 Vile Parle Weste,Mumbai-400056

3. PHILIPS [B] CATEGORY-ll


M/s. Philips Electronics india Ltd, [ENERGY SAVING T-5 TUBE
7, FITTING/CFL INDOOR TYPE]
Justice Chandra Madhad Road,
Kolkata-700020 1. SPANCO
M/s Spance Semiconductors,
4. CROMPTON 10/11, Bhagat industrial Estate,
M/s. Crompton Nr.18 No. ESI Hospital,Jay Bharat
Greeves,C.Q.Hube, Rangshala Compound,Saraspur,
6th Floor, Dr.Annie Besant Road, Ahmedabad-18
Worli, Mumbai-400030
2. WIPRO
2.6 ENERGY SAVING FLOURESCENT M/s Wipro Ltd,A/210,Fairdal
TUBE & CFL FITTINGS (Box Type/ House,
Industrial Type / Mirror Optic / Opp St Xaviers Ladies Hostel,
Mirror Navrangpura, Ahmedabad
Light / Street Light )
(A) CATEGORY – I 3. PRESTOLITE

Signature of Contractor 270


M/s PRESTOLITE
CORPORATION,57/5, Khalil Seth 11. C&S GEWISS
Compound, Off. M.G.Road, M/s Control & Switchgears
Goregaon (W) Mumbai-400062 Contactors Ltd .9th
Floor,HERITAGE, Nr.Gujarat
4. GRE Vidyapith, Ashram Road
M/s GRE Electronics, Plot ,Ahmedabad-380009
No.423,
G.I.D.C-II, Dediyasan, Mehsan- 12. CILVER
384002 M/s United Himalyan
ind,PL.No.16,17,Sector No.5,
5. TEKNOLITE Parwanoo, Dist-Solan,
M/s Teknovision Allied Product HIMACHALPRADESH
P.L.
16, Waman Patil industrial Estate, 13. INDOASIAN
Nr. Dukes Factory, Nr.Chembur, M/s lndo Asian Fusegeear
Mumbai-71 Limited,
6. ARYA 203-204 Shreedhar Avenue,11,
M/s Arya Filaments P.L.344 Sardar patel Colony, Nr.Sarder
Vishnupuri Patel Statue,
Annex.A.B.Road,indore-452001 Naranpura,Ahmedabad-380014

7. SHAKTI (B) CATEGORY-II


M/s Shakti Fixture industries [ENERGY SAVING T-5 TUBE
212/B FITTING/CFL OUTOOR TYPE]
Bombay Talkies Compound Malad 1. WIPRO
(W), Mumbai-400064 M/s Wipro Ltd,A/210, Fairdeal
house,Opp St.Xavier‟s Ladies
8. JILCO Hostel, Navangpura, Ahmedabad
M/S JAIN INDUSTRIAL LIGHTING
CORP.B-70/22, DSIDC Complex, 2. GRE
Lawrence Road New Delhi-35 M/s GRE Electronics, Plot No.423
G.I.D.C.-II Dediyasan, Mehsan-
9. ANCHOR 384002
M/s Anchor Electrical
P.L.Marathon lnnova, C-Wing, 3. SHAKTI
Opp.Peninsula Corporate M/s Shakti Fixture industries
Park,Of.G.K.Marg, Lower Parel 212/B
(W), MUMBAI-13 Bombay Talkies Compound Malad
(W),Mumbai-400064
10. GLOMORE
M/s Devraj Enterprises (P) 4. JILCO
Ltd,401, M/S JAIN INDUSTRIALLIGHTING
Sobhna Appartment,4th CORP.B-70/22 DSIDC COMPLEX
Floor,Above LAWRENCE ROAD,NEW DELHI-35
Mandavi Bank, Chandravarkar
Road, 5. CILVER
Borivali [W] Mumbai – 400092

Signature of Contractor 271


M/s United Himalyan ind
.PL.NO.16,17, Sector No.5, 8. CROMPTON
Parwanoo.Dist –Solan, Himachal M/s. Crompton
Pradesh Greeves,C.Q.Hube,6th
Floor,Dr.Annie Besant
(C) CATEGORY-III Road,Worli,Mumbai-400030
(D) CATEGORY-III
[ENERGY SAVING T-5 TUBE [ENERGY SAVING T-5 TUBE
FITTING/CFL INDOOR TYPE] FITTING/CFL OUTOOR TYPE]
1. BAJAJ
M/S Bajaj Electricals Limited,106, 1. HAVELL‟S
1st Fl. Sakar-III, Nr.Ashram M/s Havell‟s India Ltd,202-
Road, Navrangpura, Ahmedabad- 205,SHIVALIK II,Nr. Shivranjani
380014 Cross Road, Satelite 132 Ft. Ring
2. HAVELL‟S Road,Ahmedabad-380015
M/s Havell‟s India Ltd,202-
205,SHIVALIK II, Nr Shivranjani 2. SURYA
Cross Road, Satelite 132 Ft.Ring M/S Surya Roshni Ltd.( Lighting
Road,Ahmedabad-380015 Division)308 Shefali Centre, Nr.
Paldi Char Rasta, Ahmedabad-
3. SURYA 380006
M/S Surya Roshni Ltd, (Lighting
Division) 308, Shefali Centre, Nr. 3. PIERLITE
Paldi Char Rasta. Ahmedabad- M/S PIERLITE INDIA PVT.LTD
380006 RAKHIL ROAD,AHMEDABAD

4. ASIAN 4. PHILIPS
M/s ASIAN ELECTRONICS LTD M/s Philips Electronics India
11-14, Tej Complex, Nr.Lions Ltd,7, Justice Chandra Madhad
Hall,Opp Ashoka Road,Kolkata-700020
Chambers,Mithakhali,Ellisbridge,
Ahmedabad-380006-india 5. CROMPTON
M/s Crompton Greeves,C.Q.
5. PIERLITE Hube,6th Floor,Dr.Annie Besant
M/S PIERLITE INDIA PVT.LTD Road,Worli,Mumbai-400030
RAKHIL ROAD,AHMEDABAD
2.7 FLOURESCENT TUBE FITTINGS
6. GE [ELECTRONICS BALLAST]
M/s GE India industrial Pvt.Ltd, (Box Type/ industrial Type/Mirror
405,”Kirtiman”, Kinariwala Optic/Mirror Light/Street Light)
House,B/H (A) CATEGORY-I
Citibank,Off.C.G.Road,Ahmedaba ANY ISI MARKED
d-09 (B) CATEGORY-II
1. SPANCO
7. PHILIPS M/S Spance Semiconuctors,
M/s. Philips Electronics India 10/11,Bhagat industrial
Ltd,7,Justice Chandra Madhad Estate,
Raod, Kolkata-700020

Signature of Contractor 272


Nr.18No.ESI Hospital,Jay Mumbai-400071
Bharat
Rangshala 8. ARYA
Compound,Saraspur, M/s Arya Filaments P.L.344,
Ahmedabad-380018 Vishnupuri Annex
A.B.Road,indore-
2. WIPRO 452001
M/s WIPRO LTD,611-615,
Commodity Exchange 9. PIERLITE
Building,Sector No.19, Vashi, M/S PIERLITE INDIA PVT.LTD
Navi Mumbai,400705(India) RAKHIL ROAD,AHMEDABAD

3. PRESTOLITE 10. INDOASIAN


M/s PRESTOLITE M/s lndo Asian Fusegeear
, Limited,
CORPORATION,57/5,Khalil 203-204,Shreedhar Avenue,11,
Seth Sarder Patel Colony,Nr.Sarder
Compound,Off. M.G.Road, Patel
Goregaon (W) Mumbai- Statue,Naranpura,Ahmedabad-
400062 380014

4. C&S GEWISS 11. GRE


M/s.Control & Switchgears M/s GRE Electronics,Plot No.423
Contactors Ltd.9th G.I.D.C.-II,Dediyasan Mehsana-
Floor,HERITAGE 384002
Nr.Gujarat Vidyapith, Ashram
Road, 12. JILCO
Ahmedabad-380009 M/S JAIN INDUSTRIAL LIGHTING
CORP.B-70/22 DSIDS COMPLEX,
5.
GLOMORE LAWRENCE ROAD,NEW DELHI-35
M/S DEVRAJ ENTERPRIES (P)
LTD,GALA NO.3-4,GEETAIND. 13. SHAKTI
ESTATE NO.6 M/s Shakti Fixture industries
VIL.GOKHIWARE 212/B,
VASAI (E),THANE Bombay Talkies Compound Malad
(W) Mumbai-64
6. SHAH
M/S SHAH ELECTRONICS, 14. CILVER
A-3,MANOHARVILA,NEW NA M/S UNITED HIMALYAN
ROAD,NICOL ROAD,NR.NARODA INDUSTRIES
CANAL,NICOL,AHMEDABAD- PL.NO.16,17,SECTOR NO.5,
PARWANOO,DIST.SOLAN,
7. TEKNOLITE HIMACHALPRADESH
M/s Teknovision Allied Product
P.L. 15. ANCHOR
16,Waman Patil industrial M/s Anchor Electrical
Estate, P.L.Marathon lnnova,C-Wing,
Nr. Dukes Factory, Nr.Chembur, Opp. Peninsula Corporate Park,

Signature of Contractor 273


Of.G.K.Marg.Lower Parel (W) M/s Bajaj Electricals
,MUMBAI-13 Limited.106,
1st Fl. Sakar – III, Nr.Ashram
16. G.E. Road
M/s GE India industrial Pvt.Ltd Navrangpura, Ahmedabad -
405,”Kirtiman”,Kinariwala 380014
House,B/H
Citibank,Off.C.G.Road,Ahmedaba 2.8 MERCURY VAPOUR LAMP FITTINGS
d-09 (POST TOP LANTERN/STREET
LIGHTS)
(A) CATEGORY-I
17. FIXOLITE 1. GLOMORE
M/s FIXOLITE INDUSTRES M/s Devraj Enterprises (P)
305,Abdul Rehman Ltd,401, Sobhna
Street,Mumbai-400003 Appartment,4th
(C) CATEGORY-III Floor,Above Mandavi Bank,
1. PHILIPS Chandravarkar Road, Borivali
M/s Philips Electronics India [W]
Ltd,7, Mumbai – 400092
Justice Chandra Madhab
Road, 2. WIPRO
Kolkata-700020 M/s Wipro Ltd,A/210, Fairdeal
house,Opp St.Xavier‟s Ladies
2.
CROMPTON Hostel, Navangpura,
M/s Crompton Ahmedabad
Greeves,C.Q.Hube
6th Floor, Dr.Annie Besant 3. C&S GEWISS
Road, M/s.Control & Switchgears
Worli,Mumbai-400030 Contactors Ltd.9th
Floor,HERITAGE
3. SURYA Nr.Gujarat Vidyapith, Ashram
M/S Surya Roshni Road,
Ltd,(Lighting Ahmedabad-380009
Division) 308,Shefali Centre,
Nr. 4. GRE
Paldi Char M/s GRE Electronics,Plot No.423
Rasta,Ahmedabad- G.I.D.C.-II,Dediyasan Mehsana.
380006 5. ARYA
M/s Arya Filaments P.L.344,
4. HAVELL‟S Vishnupuri Annex
M/s Havell‟s India Ltd,202- A.B.Road,indore-
205,SHIVALIK II,Nr. 452001
Shivranjani
Cross Road, Satelite 132 Ft. 6. JILCO
Ring M/S JAIN INDUSTRIAL LIGHTING
Road,Ahmedabad-380015 CORP.B-70/22 DSIDS COMPLEX,
LAWRENCE ROAD,NEW DELHI-35
5. BAJAJ

Signature of Contractor 274


7. SHAKTI 2. PRESTOLITE
M/s Shakti Fixture industries M/s PRESTOLITE
212/B, ,
Bombay Talkies Compound Malad CORPORATION,57/5,Khalil
(W) Mumbai-64 Seth
Compound,Off. M.G.Road,
8. CILVER Goregaon (W) Mumbai-
M/S UNITED HIMALYAN 400062
INDUSTRIES
PL.NO.16,17,SECTOR NO.5, 3. SURYA
PARWANOO,DIST.SOLAN, M/S Surya Roshni
HIMACHALPRADESH Ltd,(Lighting
Division) 308,Shefali Centre,
9. PIERLITE Nr.
M/S PIERLITE INDIA PVT.LTD Paldi Char Rasta,Ahmedabad
RAKHIL ROAD,AHMEDABAD 4. PHILIPS
M/s Philips Electronics India
10. ANCHOR Ltd,7,
M/s Anchor Electrical Justice Chandra Madhab
P.L.Marathon lnnova,C-Wing, Road,
Opp. Peninsula Corporate Park, Kolkata-700020
Of.G.K.Marg.Lower Parel (W)
,MUMBAI-13 5. CROMPTON
M/s Crompton
11. BAJAJ Greeves,C.Q.Hube
M/s Bajaj Electricals 6th Floor, Dr.Annie Besant
Limited.106, Road,
1st Fl. Sakar – III, Nr.Ashram Worli,Mumbai-400030
Road
Navrangpura, Ahmedabad - 2.9 SODIUM VAPOUR LAMP FITTING
380014 (POST TOP LANTERN/STREET
LIGHTS)
12. FIXOLITE (A) CATEGORY-I
M/s FIXOLITE INDUSTRES 1. GLOMORE
305,Abdul Rehman M/s Devraj Enterprises (P)
Street,Mumbai- Ltd,401, Sobhna
400003 Appartment,4th
Floor,Above Mandavi Bank,
(C) CATEGORY-III Chandravarkar Road, Borivali
[W]
1. HAVELL‟S Mumbai – 400092
M/s Havell‟s India Ltd,202-
205,SHIVALIK II,Nr. (B) CATEGORY-II
Shivranjani 1. SPANCO
Cross Road, Satelite 132 Ft. M/S Spance Semiconuctors,
Ring 10/11,Bhagat industrial
Road,Ahmedabad-380015 Estate,

Signature of Contractor 275


Nr.18No.ESI Hospital,Jay Bombay Talkies Compound Malad
Bharat (W) Mumbai-64
Rangshala
Compound,Saraspur, 9. CILVER
Ahmedabad-380018 M/S UNITED HIMALYAN
INDUSTRIES
2. WIPRO PL.NO.16,17,SECTOR NO.5,
M/s WIPRO LTD,611-615, PARWANOO,DIST.SOLAN,
Commodity Exchange HIMACHALPRADESH
Building,Sector No.19, Vashi,
Navi Mumbai,400705(India) 10. ANCHOR
M/s Anchor Electrical
3. PRESTOLITE P.L.Marathon lnnova,C-Wing,
M/s PRESTOLITE Opp. Peninsula Corporate Park,
, Of.G.K.Marg.Lower Parel (W)
CORPORATION,57/5,Khalil ,MUMBAI-13
Seth
Compound,Off. M.G.Road, 11. G.E.
Goregaon (W) Mumbai- M/s GE India industrial Pvt.Ltd
400062 405,”Kirtiman”,Kinariwala
House,B/H
4. C&S GEWISS
M/s.Control & Switchgears Citibank,Off.C.G.Road,Ahmedabad-
Contactors Ltd.9th 09
Floor,HERITAGE
Nr.Gujarat Vidyapith, Ashram 12. BAJAJ
Road, M/s Bajaj Electricals
Ahmedabad-380009 Limited.106,
1st Fl. Sakar – III, Nr.Ashram
5. GRE Road
M/s GRE Electronics,Plot No.423 Navrangpura, Ahmedabad -
G.I.D.C.-II,Dediyasan Mehsana- 380014
384002
13. FIXOLITE
6. ARYA M/s FIXOLITE INDUSTRES
M/s Arya Filaments P.L.344, 305,Abdul Rehman
Vishnupuri Annex Street,Mumbai-
A.B.Road,indore- 400003
452001 (C) CATEGORY-III

7. JILCO 1. HAVELL‟S
M/S JAIN INDUSTRIAL LIGHTING M/s Havell‟s India Ltd,202-
CORP.B-70/22 DSIDS COMPLEX, 205,SHIVALIK II,Nr.
LAWRENCE ROAD,NEW DELHI-35 Shivranjani
Cross Road, Satelite 132
8. SHAKTI Ft. Ring
M/s Shakti Fixture industries Road,Ahmedabad-380015
212/B,

Signature of Contractor 276


2.
PIERLITE Nr.18No.ESI Hospital,Jay
M/S PIERLITE INDIA Bharat Rangshala
PVT.LTD Compound,Saraspur,
RAKHIL ROAD,AHMEDABAD Ahmedabad-380018

3. SURYA 2. WIPRO
M/S Surya Roshni M/s Wipro Ltd,A/210,
Ltd,(Lighting Fairdeal
Division) 308,Shefali house,Opp St.Xavier‟s
Centre, Nr. Ladies
Paldi Char Hostel, Navangpura,
Rasta,Ahmedabad- Ahmedabad
380006
3. PRESTOLITE
4. G.E.SR/SPPT/OPTYLANE M/s PRESTOLITE
M/s GE India industrial ,
Pvt.Ltd CORPORATION,57/5,Khalil
405,”Kirtiman”,Kinariwala Seth
House,B/H Nr.Gujarat Compound,Off. M.G.Road,
Vidyapith, Ashram Road, Goregaon (W) Mumbai-400062
Ahmedabad-380009
4. C&S GEWISS
5. PHILIPS M/s.Control & Switchgears
M/s Philips Electronics Contactors Ltd.9th
India Floor,HERITAGE
Ltd,7, Justice Chandra Nr.Gujarat Vidyapith, Ashram
Madhab Road,
Road, Kolkata-700020 Ahmedabad-380009

6. CROMPTON 5. GLOMORE
M/s Crompton M/s Devraj Enterprises (P)
Greeves,C.Q.Hube 6th Ltd,401, Sobhna
Floor, Appartment,4th
Dr.Annie Besant Road, Floor,Above Mandavi Bank,
Worli,Mumbai-400030 Chandravarkar Road, Borivali
[W]
2.10 FLOOD LIGHTS WITH Mumbai – 400092
BC/ES/MV/SV/MH/LAMPS
(POST TOP LANTERN/STREET 6. GRE
LIGHTS) M/s GRE Electronics,Plot No.423
(A) CATEGORY-I G.I.D.C.-II,Dediyasan Mehsana-
ANY ISI MARKED 384002
(B) CATEGORY-II
1 . SPANCO 7. ARYA
M/S Spance M/s Arya Filaments P.L.344,
Semiconuctors, Vishnupuri Annex
10/11,Bhagat industrial A.B.Road,indore-
Estate, 452001

Signature of Contractor 277


Satelite 132 Ft. Ring
8. JILCO Road,Ahmedabad-380015
M/S JAIN INDUSTRIAL LIGHTING
CORP.B-70/22 DSIDS COMPLEX, 2. PIERLITE
LAWRENCE ROAD,NEW DELHI-35 M/S PIERLITE INDIA
PVT.LTD RAKHIL
9. SHAKTI ROAD,AHMEDABAD
M/s Shakti Fixture industries
212/B, 3. SURYA
Bombay Talkies Compound Malad M/S Surya Roshni
(W) Mumbai-64 Ltd,(Lighting Division)
308,Shefali Centre, Nr.
10. ANCHOR Paldi Char
M/s Anchor Electrical Rasta,Ahmedabad-
P.L.Marathon lnnova,C-Wing, 380006
Opp. Peninsula Corporate Park,
Of.G.K.Marg.Lower Parel (W) 4. G.E.SF/GEMF/BLAZE
,MUMBAI-13 M/s GE India industrial
Pvt.Ltd
11. G.E. 405,”Kirtiman”,Kinariwala
M/s GE India industrial Pvt.Ltd House,B/H Nr.Gujarat
405,”Kirtiman”,Kinariwala Vidyapith, Ashram Road,
House,B/H Ahmedabad-380009

Citibank,Off.C.G.Road,Ahmedabad- 5. PHILIPS
09 M/s Philips Electronics
India
12. BAJAJ Ltd,7, Justice Chandra
M/s Bajaj Electricals Madhab
Limited.106, Road, Kolkata-700020
1st Fl. Sakar – III, Nr.Ashram
Road 6. CROMPTON
Navrangpura, Ahmedabad M/s Crompton
- Greeves,C.Q.Hube 6th
380014 Floor,
Dr.Annie Besant Road,
13. FIXOLITE Worli,Mumbai-400030
M/s FIXOLITE INDUSTRES
305,Abdul Rehman 2.11 Halogen Tube Fitting
Street,Mumbai- (A) Cat.II
400003 1. ARYA
M/s Arya Filaments
(C) CATEGORY-III P.L.344,
1. HAVELL‟S Vishnupuri Annex
M/s Havell‟s India A.B.Road,indore- 452001
Ltd,202-
205,SHIVALIK II,Nr. 2.12 ELETRONIC BALLAST
Shivranjani Cross Road, (A) CATEGORY-I

Signature of Contractor 278


Estate,B/h Lubi
1 . SHAH Elect.,Memco, Naroda
M/S SHAH ELECTRONICS, Road, Ahmedabad
A-3,MANOHARVILA,NEW
NA 8. PLUSE
ROAD, NICOL ROAD, NR. M/s Pulse Electronics &
NARODACANAL, NICOL, Control, B/1, Maruti
AHMEDABAD- 382330 Tenament, Opp.Shriji Bapa
Complex, Nr. Rabari
2. AMIT Colony,Vastral To Odhav
M/s. Amit Electro Plast, Canal Road, Ahmedabad
105, 1st
Floor, Sarvoday Comm. (B) CATEGORY-II
Centre, Salapose Road, Nr. 1. SPANCO
G.P.O. Ahmedabad – M/S Spance
380001. Semiconuctors,
10/11,Bhagat industrial
3. INAVA Estate,
M/s lnava instruments Nr.18No.ESI Hospital,Jay
international Bharat Rangshala
94,Ratnajyot ind. Estate Compound,Saraspur,
lrla Lane, Vile Parle Weste, Ahmedabad-380018
Mumbai-400056
2. WIPRO
4. GELCO-APPROVED M/s Wipro Ltd,A/210,
M/S. GELCO Fairdeal
ELECTRONICS P.L., 6,7,8 house,Opp St.Xavier‟s
&16, Amarnath Estate, Nr. Ladies
Krishna Gopal Estate, Hostel, Navangpura,
Naroda Road, Ahmedabad. Ahmedabad

5. ANCHOR-APPROVED 3. C&S GEWISS


M/s Anchor Electrical P. L. M/s.Control & Switchgears
Marathon lnnova,C-Wing, Contactors Ltd. 9th Floor,
Opp. Peninsula Corporate HERITAGE Nr.Gujarat
Park, Of.G.K.Marg.Lower Vidyapith, Ashram Road,
Parel (W) MUMBAI-13 Ahmedabad-380009

6. CILVER 4. GLOMORE
M/S UNITED HIMALYAN M/s Devraj Enterprises (P)
INDUSTRIES P. L. Ltd,401, Sobhna
NO.16,17,SECTOR Appartment,4th
NO. 5, PARWANOO, Floor,Above
DIST.SOLAN, Mandavi Bank,
HIMACHALPRADESH Chandravarkar Road,
7. OCLEG Borivali
M/s.OCLEG [W] Mumbai – 400092
CONTROLS,93- 94, Amar

Signature of Contractor 279


5. TEKNOLITE
M/s Teknovision Allied 12. ANCHOR
Product P.L. 16, Waman M/s Anchor Electrical P.L.
Patil Marathon lnnova,C-Wing,
industrial Estate, Nr. Dukes Opp. Peninsula Corporate
Factory, Nr.Chembur, Park, Of.G.K.Marg.Lower
Mumbai-71 Parel (W), MUMBAI-13

6. GELCO 13. SHAH


M/S. GELCO ELECTRONICS M/s Shah Electronics,
P.L., 6,7,8 &16, Amarnath A-3,Manoharvila, New
Estate, Nr. Krishna Gopal Naroad,
Estate, Naroda Road, Nicol Road,Nr.Naroda
Ahmedabad. Canal,
Nicol,Ahmedabad –
7. INDOASIAN 382330
M/s indo Asain Fusegear
Limited, 203-204, 14. ASIAN
Shreedhar M/s ASIAN ELECTRONICS
Avenue, 11, Sardar Patel LTD
Colony, Nr. Sardar Patel 11-14, Tej Complex,
Statue, Naranpura, Nr.Lions Hall, Opp Ashoka
Ahmedabad. Chambers, Mithakhali,
Ellisbridge,
8. GRE Ahmedabad-380006-india
M/s GRE Electronics,Plot
No.423 G.I.D.C.- 15. OSRAM
II,Dediyasan M/s. Osram India P. L., Delhi
Mehsana- 384002 Road,
Sonipat, Haryana-131001.
9. ARYA
M/s Arya Filaments (C) CATEGORY-III
P.L.344,
Vishnupuri Annex 1. HAVELL‟S
A.B.Road,indore-452001 M/s Havell‟s India Ltd,202-
205,SHIVALIK II,Nr.
10 JILCO Shivranjani
M/S JAIN INDUSTRIAL Cross Road, Satelite 132 Ft.
LIGHTING CORP. B-70/22 Ring
DSIDS COMPLEX, Road,Ahmedabad-380015
LAWRENCE ROAD,NEW
DELHI-35 2. PIERLITE
M/S PIERLITE INDIA PVT.LTD
11. SHAKTI RAKHIL ROAD,AHMEDABAD
M/s Shakti Fixture
industries 212/B, Bombay 3. PHILIPS
Talkies Compound Malad M/s. Philips Electronics India
(W) Mumbai-64 Ltd., 7,

Signature of Contractor 280


Justice Chandra Madhab Road, Smruti Mandir,Ghodasar
Kolkata-700020. Ahmedabad

4. CROMPTON 5. SUPER
M/s. Crompton Greeves, C.Q. M/SSUPER SWITCHGEARS
Hube, SHED-C,5/6,GIDC
6th Floor, Dr. Annie Besant VITTHAL UDHYOG
Road, NAGAR,V.V.NAGER-
Worli, Mumbai – 400030. 388121

CHAPTER-III (C) CATEGORY-III


SWITCHGEARS&DISTRIBUTION 1. KEW
BOARDS M/s KEW FUSEGEAR
PVT.LTD C1 B/336/38,
CAST IRON CLAD SWITCHES G.I.D.C.Estate,Makarpura
WITH REWIREBLEFUSE ,
(A) CATEGORY-I Vadodara-390010
ANY OTHER THEN
FOLLOWING MAKE 2. STENLY
(B) CATEGORY-II
1. TRISUL 3.2 METAL CLAD SWITCHES
M/s Aum Electrical WITH
Industries, REWIREBLE FUSE (63A-100A)
1014,GIDC,Waghodia- (A) CATEGORY-I
391760 Gujarat
1. REIKO
2. MODI M/S R.L.Electrical industries, 8, Sri
M/S MODI INDUSTRIES, Ram Marg,Opp Central Bank,
61,Mahaveer Moujpur Road,Shahdara,Delhi-
Estate,Nr.Anupam Cinema, 110053 (INDIA)
Khokhara,Ahmedabad- (B) CATEGORY-II
380008 1. KEW
M/s KEW FUSEGEAR PVT.LTD
3. NEW/NILANG C1
M/s Nilang Engineerign B/336/38,
Works,Plot No.156/2,A-31 G.I.D.C.Estate,Makarpura,
Kailshnagar Estate,Opp Vadodara-390010
New
Tele.Exchange,F 2. SIGMA
Road,G.I.D.C.Vatva, M/s MCB Electro Controles,C-
Ahmedabad-382445 176
Mayapuri industrial Area,Phase
4. PEW –ii,
M/s Patel Engineering New Delhi-110064
Works,
23, 3. TRISHUL
Vrundavandham,Society,O M/s Aum Electrical
pp.P.d.Pandya Collage,Nr industries,1014,

Signature of Contractor 281


GIDC,Wagnodia-391760 Satelite 132 Ft. Ring
Gujarat Road
Ahmedabad-380015
4. MODI 4. L&T
M/S MODI INDUSTRIES, M/s L&T House,Ballord
61,Mahaveer Estate,Nr.Anupam Estate,P.O.Box No.278
Cinema, Khokhara,Ahmedabad- Mumbai-400001
380008
5. CROMPTON
5. PEW M/s. Crompton
M/s Patel Engineering Works,23, Greeves,
Vrundavandham,Socity, Opp P.d C.Q. Hube, 6th Floor,
Pandya Collage,Nr. Smruti Dr.
Mandir, Annie Besant Road,
Ghodasar,Ahmedabad Worli,
Mumbai – 400030.
6. SUPER
M/SSUPER SWITCHGEARS 6. C&S GEWISS
SHED-C,5/6,GIDC VITTHAL M/s. Control &
UDHYOG NAGAR,V.V.NAGER- Switchgears
388121 Contractors Ltd., 9th
Floor,
7. HPL HERITAGE, Nr. Gujarat
Vidyapith, Ashram
(C) CATEGORY-III Road,
1. HAVELL‟S Ahmedabad-380 009.
M/s Havell‟s India Ltd,202-
205,SHIVALIK II,Nr. METAL CLAD SWITCHES
Shivranjani WITH HRC FUSE
Cross Road, Satelite 132 Ft.
Ring (A) CATEGORY-II
Road,Ahmedabad-380015 1. KEW
M/s KEW FUSEGEAR
2. INDOASIAN PVT.LTD C1 B/336/38,
M/s indo Asain Fusegear G.I.D.C.Estate,Makarpura
Limited, ,
203-204, Shreedhar Avenue, 11, Vadodara-390010
Sardar Patel Colony, Nr. Sardar
Patel Statue, Naranpura, 2. PIERLITE
Ahmedabad. M/S PIERLITE INDIA
PVT.LTD RAKHIL
3. STANDARD ROAD,AHMEDABAD
M/s.Standard
Electrical Ltd 3. PEW
202,205 Shivalik-II M/s Patel Engineering
N.R. Works,
Shivranjani Cross 23,
Road, Vrundavandham,Society,O

Signature of Contractor 282


pp.P.d.Pandya Collage,Nr Contractors Ltd., 9th Floor,
Smruti Mandir,Ghodasar HERITAGE, Nr. Gujarat
Ahmedabad Vidyapith, Ashram Road,
Ahmedabad-380 009.
4. SUPER
M/SSUPER SWITCHGEARS 5. L&T
SHED-C,5/6,GIDC M/s L&T House,Ballord
VITTHAL UDHYOG Estate,P.O.Box No.278
NAGAR,V.V.NAGER- Mumbai-400001
388121
6. Siemens
M/s Siemens Ltd L.V.Control &
5. CROMPTON Distribution Products Thane
Belapur Road,Thane-400601

M/s. Crompton Greeves, C.Q. 7. GE


Hube, 6th Floor, Dr. Annie M/s GE india industrial Pvt. Ltd.,
Besant 405, “Kirtiman”,Kinariwala House,
Road, Worli, Mumbai – 400030. B/H Citibank, Off. C.G.Road,
Ahmedabad – 09
6. HPL
3.4 MOULDED CASE CIRCUIT BREAKERS
(B) CATEGORY-III (A) CATEGORY-I
1. HAVELL‟S 1. GUTS
M/s Havell‟s India Ltd,202- M/s GUTS ELECTROMECH LTD
205,SHIVALIK II,Nr. 119, Trinity Co.Op.Hsg.Soc.1st
Shivranjani Floor, C.H.Street
Cross Road, Satelite 132 Ft. Bhobitalo,
Ring Mumbai-400002
Road,Ahmedabad-380015
1.BENTEC
2. INDOASIAN M/s. Bentec Electrical &
M/s indo Asain Fusegear Electronics P.L.No-7,
Limited, Maharaja Estate,B/h
203-204, Shreedhar Avenue, 11, Bhagyodaya
Sardar Patel Colony, Nr. Sardar Hotel,Sarkhej
Patel Statue, Naranpura, Sanad Highway
Ahmedabad.-380014 Sarkhej,
Ahmedabad-382210
3. STANDARD
M/s.Standard Electrical Ltd 2. CROMPTON
202,205 Shivalik-II N.R. M/s. Crompton Greeves,
Shivranjani Cross Road, C.Q. Hube, 6th Floor,
Satelite 132 Ft. Ring Road Dr.
Ahmedabad-380015 Annie Besant Road,
Worli,
4. C&S GEWISS Mumbai – 400030.
M/s. Control & Switchgears

Signature of Contractor 283


(C) CATEGORY-III Estate,P.O.Box No.278
1. HAVELL‟S Mumbai-400001
M/s Havell‟s India
Ltd,202- 7. Siemens
205,SHIVALIK II,Nr. M/s Siemens Ltd L.V.Control &
Shivranjani Cross Road, Distribution Products Thane
Satelite 132 Ft. Ring Belapur Road,Thane-400601
Road,Ahmedabad-380015
8. GE
2. STANDARD M/s GE india industrial Pvt. Ltd.,
M/s.Standard Electrical 405, “Kirtiman”,Kinariwala
Ltd House, B/H Citibank, Off.
202,205 Shivalik-II N.R. C.G.Road, Ahmedabad – 09
Shivranjani Cross Road,
Satelite 132 Ft. Ring 3.5 AIR CIRCUIT BREAKERS
Road (A) APPROVED
Ahmedabad-380015 1. HAVELL‟S
M/s Havell‟s India Ltd,202-
3. BCH 205,SHIVALIK II,Nr.
M/s BCH Electric Limited Shivranjani Cross Road,
93, Satelite 132 Ft. Ring
City Centre,Nr.Swastik Road,Ahmedabad-380015
Char
(B) CATEGORY-III
Rasta,C.G.Road,Ahmedabad 1. C&S GEWISS
380009 M/s. Control & Switchgears
Contractors Ltd., 9th Floor,
4. C&S GEWISS HERITAGE, Nr. Gujarat
M/s. Control & Vidyapith, Ashram Road,
Switchgears Ahmedabad-380 009.
Contractors Ltd., 9th
Floor, 2. INDOASIAN
HERITAGE, Nr. Gujarat M/s indo Asain Fusegear
Vidyapith, Ashram Road, Limited, 203-204, Shreedhar
Ahmedabad-380 009. Avenue, 11, Sardar Patel
Colony, Nr. Sardar Patel
5. INDOASIAN Statue, Naranpura,
M/s indo Asain Fusegear Ahmedabad.-380014
Limited, 203-204,
Shreedhar 3. GE
Avenue, 11, Sardar M/s GE india industrial Pvt. Ltd.,
Patel 405, “Kirtiman”,Kinariwala
Colony, Nr. Sardar Patel House,
Statue, Naranpura, B/H Citibank, Off. C.G.Road,
Ahmedabad.-380014 Ahmedabad – 09

6. L&T 4. CROMPTON
M/s L&T House,Ballord M/s. Crompton Greeves,

Signature of Contractor 284


C.Q. Hube, 6th Floor, Dr. Vrundavandham,Socity,
Annie Besant Road, Worli, Opp
Mumbai – 400030. P.d Pandya Collage,Nr.
Smruti Mandir,
5. L&T Ghodasar,Ahmedabad
M/s L&T House,Ballord
Estate,P.O.Box No.278 2. KEW
Mumbai-400001 M/s KEW FUSEGEAR
PVT.LTD C1 B/336/38,
6. Siemens
M/s Siemens Ltd G.I.D.C.Estate,Makarpura,
L.V.Control & Vadodara-390010
Distribution Products
Thane 3. SIGMA
Belapur Road,Thane- M/s MCB Electro
400601 Controles,C-
176 Mayapuri industrial
CHANGE OVER SWITCHES Area,Phase –ii, New
(A) CATEGORY-I Delhi-
1 . GUTS 110064
M/s GUTS ELECTROMECH
LTD 119, Trinity 4. BENTEC
Co.Op.Hsg.Soc.1st M/s. Bentec Electrical &
Floor, C.H.Street Electronics P.L.No-7,
Bhobitalo, Maharaja Estate,B/h
Mumbai-400002 Bhagyodaya
Hotel,Sarkhej
2. MODI Sanad Highway Sarkhej,
M/S MODI INDUSTRIES, Ahmedabad-382210
61,Mahaveer
Estate,Nr.Anupam
Cinema,
Khokhara,Ahmedabad- 5. PIERLITE
380008 M/S PIERLITE INDIA
PVT.LTD RAKHIL
3. REIKO ROAD,AHMEDABAD
M/S R.L.Electrical industries,
8, 6. NEW/NILANG
Sri Ram Marg,Opp Central M/s Nilang Engineerign
Bank, Moujpur Works,Plot
Road,Shahdara,Delhi- No.156/2,A-31 Kailshnagar
110053 Estate,Opp New
(INDIA) Tele.Exchange,F
Road,G.I.D.C.Vatva,
(B) CATEGORY-II Ahmedabad-382445
1. PEW
M/s Patel Engineering 7. SUPER
Works,23, M/SSUPER SWITCHGEARS

Signature of Contractor 285


SHED-C,5/6,GIDC VITTHAL Belapur Road,Thane-400601
UDHYOG NAGAR,V.V.NAGER-
388121 7. CROMPTON
M/s. Crompton Greeves,
8. HPL C.Q. Hube, 6th Floor, Dr.
M/s B/707 Premium House, Nr. Annie Besant Road, Worli,
Gandhi Gram Rly.Station,B/H Mumbai – 400030.
Natraj Cinema,Ashram Road,
Ahmedabad-380009 8. GE
M/s GE india industrial Pvt.
(C) CATEGORY-III Ltd., 405, “Kirtiman”,Kinariwala
1. HAVELL‟S House, B/H Citibank, Off.
M/s Havell‟s India Ltd,202- C.G.Road, Ahmedabad – 09
205,SHIVALIK II,Nr.
Shivranjani Cross Road, MCB & MCB DISTRIBUTION BOX
Satelite 132 Ft. Ring (A) CATEGORY-I
Road,Ahmedabad-380015 1. GUTS
M/s GUTS
2. STANDARD ELECTROMECH
M/s.Standard Electrical Ltd LTD 119, Trinity
202,205 Shivalik-II N.R. Co.Op.Hsg.Soc.1st
Shivranjani Cross Road, Floor, C.H.Street Bhobitalo,
Satelite 132 Ft. Ring Road Mumbai-400002
Ahmedabad-380015
2. BALKAM
3. C&S GEWISS M/s Balkam India Ltd
M/s. Control & Switchgears B-33,Old Vishnu Garden,
Contractors Ltd., 9th Floor, New Delhi-110018
HERITAGE, Nr. Gujarat
Vidyapith, Ashram Road, 3. ESCO
Ahmedabad-380 009. M/S ELECTRO SPARES
&CO.1894/A/1 Inside
4. INDOASIAN Pade Pole Gandhi Road
M/s indo Asain Fusegear Ahmedabad-380001
Limited, 203-204, Shreedhar
Avenue, 11, Sardar Patel 4. GRE
Colony, Nr. Sardar Patel M/s GRE
Statue, Naranpura, Electronics,Plot
Ahmedabad.-380014 No.423 G.I.D.C.-
II,Dediyasan Mehsana-
5. L&T 384002
M/s L&T House,Ballord
Estate,P.O.Box No.278 5. S.G.
Mumbai-400001
(B) CATEGORY-II
6. Siemens 1. KEW
M/s Siemens Ltd L.V.Control & M/s KEW
Distribution Products Thane FUSEGEAR

Signature of Contractor 286


PVT.LTD C1 8. C&S GEWISS
B/336/38, M/s. Control & Switchgears
G.I.D.C.Estate,Makarpura, Contractors
Vadodara-390010 Ltd., 9th Floor, HERITAGE, Nr.
Gujarat
2. SIGMA Vidyapith, Ashram Road,
M/s MCB Electro Controles,C- Ahmedabad-380
176 009.
Mayapuri industrial Area,Phase
–ii, 9. HPL
New Delhi-110064 M/s B/707 Premium House, Nr.
Gandhi Gram Rly.Station,B/H
3. PIERLITE Natraj Cinema,Ashram Road,
M/S PIERLITE INDIA PVT.LTD Ahmedabad-380009
RAKHIL ROAD,AHMEDABAD
10. SUPER
4. AECO-MEFA M/SSUPER SWITCHGEARS
M/s Panjab Switchgears P.L.B-30 SHED-C,5/6,GIDC VITTHAL
Phase-V Focal Point,Dhandari UDHYOG NAGAR,V.V.NAGER-
Kalan 388121
Ludhiana-141010
11. ANCHOR
5. NEW/NILANG M/s Anchor Electrical
M/s Nilang Engineerign P.L.Marathon
Works,Plot lnnova,C-Wing, Opp. Peninsula
No.156/2,A-31 Kailshnagar Corporate Park,
Estate,Opp New Of.G.K.Marg.Lower
Tele.Exchange,F Parel (W)
Road,G.I.D.C.Vatva, ,MUMBAI-13
Ahmedabad-382445
12. ELECON-CLIPSAL
6. VINAY (C) CATEGORY-III
M/s. Vinay Electricals, 18-A, 1. HAVELL‟S
Singh M/s Havell‟s India
Industrial Estate, Bldg. No. 1, Ltd,202-
Rammandir 205,SHIVALIK II,Nr.
Road, Gorengaon (W), Shivranjani Cross Road,
Mumbai-40014 Satelite 132 Ft. Ring
Road,Ahmedabad-380015
7. LEADER 2. STANDARD
M/s. Leader Electrical P.L., M/s.Standard Electrical
Leader House, Ltd
9-B, Mahal Industrial Estate, 202,205 Shivalik-II N.R.
P.B.No. Shivranjani Cross Road,
9483, Mahakali Caves Road, Satelite 132 Ft. Ring
Andheri (E), Road
Mumbai-400 093. Ahmedabad-380015

Signature of Contractor 287


3. C&S GEWISS Co.Op.Hsg.Soc.1st
M/s. Control & Floor, C.H.Street
Switchgears Bhobitalo,
Contractors Ltd., 9th Mumbai-400002
Floor,
HERITAGE, Nr. Gujarat 2. S.G.
Vidyapith, Ashram Road, 3. OCLEG
Ahmedabad-380 009. M/s.OCLEG
CONTROLS,93-
4. INDOASIAN 94,Amar Estate,B/h Lubi
M/s indo Asain Fusegear Elect.,Memco,Naroda
Limited, 203-204, Road,Ahmedabad
Shreedhar Avenue, 11,
Sardar Patel
Colony, Nr. Sardar Patel 4. PULSE CONTROL
Statue, Naranpura, M/s Pulse Electronics &
Ahmedabad.-380014 Control,B/1, Maruti
Tenament,Opp.Shriji Bapa
5. ABB Complex , Nr.Rabari
M/S ABB Limited, 2nd Colony,
Floor, Vastral to Odhav Canal
Est Wing, Khanija Bhavan, Road,
49, Ahmedabad
Race, Course Road,
Banglore
- 560001. (B) CATEGORY-II
1. GELCO
6. L&T M/S. GELCO
M/s L&T House,Ballord ELECTRONICS
Estate,P.O.Box No.278 P.L., 6,7,8 &16,
Mumbai-400001 Amarnath Estate,
Nr. Krishna Gopal
7. MDS Estate,
Naroda Road,
8. GE Ahmedabad.
M/s GE india industrial Pvt.
Ltd., 405, 2. SIGMA
“Kirtiman”,Kinariwala M/s MCB Electro
House, B/H Citibank, Off. Controles,C-
C.G.Road, Ahmedabad – 176 Mayapuri industrial
09 Area,Phase –ii,
New Delhi-110064
3.8 ELCB & RCCB
(A) CATEGORY-I 3. BENTEC
1. GUTS M/s. Bentec Electrical &
M/s GUTS Electronics P.L.No-7,
ELECTROMECH Maharaja Estate,B/h
LTD 119, Trinity Bhagyodaya Hotel,Sarkhej

Signature of Contractor 288


Sanad Highway Sarkhej,
Ahmedabad-382210 5. AECO-MEFA
M/s Panjab Switchgears
4. PIERLITE P.L.B-
M/S PIERLITE INDIA 30 Phase-V Focal
PVT.LTD Point,Dhandari Kalan
RAKHIL Ludhiana-141010
ROAD,AHMEDABAD
6. C &S GEWISS M/s B/707 Premium
M/s. Control & House,
Switchgears Nr. Gandhi Gram
Contractors Ltd., Rly.Station,B/H
9th Floor, Natraj Cinema,Ashram
HERITAGE, Nr. Road,
Gujarat Ahmedabad-380009
Vidyapith, Ashram
Road, 11. ELECON-CLIPSAL
Ahmedabad-380009 (C) CATEGORY-III
1. STANDARD
7. GRE M/s.Standard
M/s GRE Electrical Ltd
Electronics,Plot 202,205 Shivalik-II
No.423 G.I.D.C.- N.R.
II,Dediyasan Mehsana- Shivranjani Cross
384002 Road,
Satelite 132 Ft. Ring
8. ANCHOR Road
M/s Anchor Electrical Ahmedabad-380015
P.L.Marathon
lnnova,C- 2. C &S
Wing, Opp. M/s. Control &
Peninsula Switchgears
Corporate Park, Contractors Ltd.,
th
Of.G.K.Marg.Lower 9 Floor,
Parel (W) ,MUMBAI- HERITAGE, Nr.
13 Gujarat
Vidyapith, Ashram
9. SUPER Road,
M/SSUPER Ahmedabad-380009
SWITCHGEARS
SHED-C,5/6,GIDC 3. INDOASIAN
VITTHAL M/s indo Asain
UDHYOG Fusegear
NAGAR,V.V.NAGER- Limited, 203-204,
388121 Shreedhar
Avenue, 11, Sardar Patel
10. HPL Colony, Nr. Sardar Patel
Statue, Naranpura,

Signature of Contractor 289


Ahmedabad.-380014 Road,Ahmedabad

4. ABB 4. MDS
M/S ABB Limited, 2nd
Floor, 3.10 ENERGY METER
Est Wing, Khanija Bhavan, 1. BENTEC
49, M/s. Bentec Electrical &
Race, Course Road, Electronics P.L.No-7,
Banglore Maharaja Estate,B/h
– 560001. Bhagyodaya
Hotel,Sarkhej
5. HAVELL’S Sanad Highway Sarkhej,
M/s Havell‟s India Ahmedabad-382210
Ltd,202-
205,SHIVALIK II,Nr. 2. NIPPEN
Shivranjani Cross Road, M/s NIPPEN ELECTRICAL
Satelite 132 Ft. Ring INSTRUMENTS CO,12-A,
Road,Ahmedabad- Joy
380015 Engg.Compound,Marol
Maroshi Road, Andheri
6. L&T (E)
M/s L&T House,Ballord Mumbai-59
Estate,P.O.Box No.278
Mumbai-400001 3. HPL
M/s B/707 Premium
7. MDS House,
Nr. Gandhi Gram
3.9 TIME SWITCHES Rly.Station,B/H
1. GELCO Natraj Cinema,Ashram
M/S. GELCO Road,
ELECTRONICS Ahmedabad-380009
P.L., 6,7,8 &16, Amarnath
Estate, 4. L&T
Nr. Krishna Gopal M/s L&T
Estate, House,Ballord
Naroda Road, Estate,P.O.Box
Ahmedabad. No.278
Mumbai-400001
2. L&T
M/s L&T House,Ballord 5. GE
Estate,P.O.Box No.278 M/s GE india industrial
Mumbai-400001 Pvt.
Ltd., 405,
3. OCLEG “Kirtiman”,Kinariwala
M/s.OCLEG House, B/H Citibank,
CONTROLS,93- Off.
94,Amar Estate,B/h Lubi C.G.Road, Ahmedabad
Elect.,Memco,Naroda –

Signature of Contractor 290


09 Hootaglli industrial
Area,DIC
3.11 BUSBAR CHAMBER Layout,Mysore-570018
1. PEW-APPROVED
M/s Patel Engineering 2. BHARAT
Works,23, M/s Vardhman Cables &
Vrundavandham,Socity, Controls Belgaum
Opp
P.d Pandya 3. MITUSHI
Collage,Nr. M/s SIGHT SOUND
Smruti Mandir, ELECTRONICS (I)P.L.A-
Ghodasar,Ahmedabad 128
WAZIRPUR
2. REIKO-APPROVED INDUSTRIAL
M/S R.L.Electrical AREA,DELHI-110052
industries,
8, Sri Ram Marg,Opp 4. EKTA
Central Bank, Moujpur M/s Scot innovation
Road,Shahdara,Delhi- Wires &
110053 (INDIA) Cables
P.L.195/1/197/1,
3. NEW/NILANG Jharmajri Baddi,Dist
M/s Nilang Engineerign Solan
Works,Plot No.156/2,A-31 (M.P.)
Kailshnagar Estate,Opp
New 5.
RALLISION
Tele.Exchange,F M/s RALLISON
Road,G.I.D.C.Vatva, ELECTRICAL
Ahmedabad-382445 P.L.205, Shreyas
Complex,
CHAPTER-IV Opp.Jain Derasar
CABLES& WIRES
ALLUMINIUM & COPPER XLPE Navrangpura,Ahmedabad-
CABLES (ALL TYPE) 380009
1.UP TO 35SQ.MM ANY ISI
MARKED 6. LOOKMAN
M/s ODIAN INDUSTRIES,
Opp.Ravi Vidhyalaya,Nr.
ALLUMINIUM&COPPER XLPE Gandhi Society,Jamnagar
CABLES(ALL TYPE) Road,Madhapar,Rajkot-
ABOVE 35 SQ.MM&UP 360006
TO185
SQ.MM 7. NIKI
M/s NIKi Cables
1. VARSHA Industries,E/
M/s VARSHA CABLES 9 B Panchratna
PVT Appt.Opp.
LTD. Plot No.65,A-2,

Signature of Contractor 291


Sunview M/S DIMOND POWER
Tower,Memnagar INFRA.LTD.PHASE II,
Ahmedabad-52 VILLAGE
VADALA,TA.SAVLI
8. KEI VADODARA
M/s KEI INDUSTRIES
LIMITED ALLUMINIUM & COPPER
803, Siddharth Compiex, XLPE CABLES (ALL Type)
Nr. ABOVE 185 SQ.MM
Hotel Express, R.C.Dutt 1. HAVELL’S
Road, M/s Havell‟s India
Baroda-390007 Ltd,202-
205,SHIVALIK II,Nr.
9. FINOLEX Shivranjani Cross
M/s Finolex Cables India Road,
108, Satelite 132 Ft. Ring
Mahakant Building, Road,Ahmedabad-
Opp.V.S. 380015
Hospital,Ashram Road,
Ahmedabad-380006 2. ALLCAB
M/s.ALLWIN
10. CABCOM INDUSTIRES,
M/s Cabcom Serve No.251,Plot
rd
India,304,3 No.7,B/h
Floor,Aggarwal citi Mall Devsaon
(Opp Ceramic,Shapar-
M2K Pitam Pura Veraval Dist-Rajkot
Multiplex)
Road No.44, Pitampura, 3. TEREXEL
Delhi-110034 M/s Teracom Limited,
“Teracom House,B-84,
11. KAMALEX Sector No.60,Nodia-
M/s Bhumi Cbles & Wires 201301
Pvt U.P.(INDIA)
Ltd.Plot No.D-
101/102,Road- 4. TERACAB INDIA
C,Lodhika M/S TERA CABLES &
G.I.D.C.(Metoda) IND.P.L.VILLAGE-
Kalawad Road,Rajkot
KALANA,PO.CHHARODI
12. MECAB FARM,SANAND,
M/s MECAB Cables AHMEDABAD
P.L.635/ 5. AVOCAB
A,Phase M/s Chandresh Cables
IV,GIDC,VATVA, Ltd.G-6
Ahmedabad-382445 New Madhavpura
Market,Nr.
13. DICAB. Police Commi.Office,

Signature of Contractor 292


Shaibaug (M.P.)
Road,Ahmedabad
380004 4. TERACAB INDIA
M/S TERA CABLES &
6. GEMSCAB IND.P.L.VILLAGE-
M/S GEMSCAB IND.LTD. KALANA,PO.CHHARODI
PREM SADAN-11, FARM,SANAND,
RAJENDRA PLACE AHMEDABAD
NEW DELHI-110008
5. EcoTEKZHFR
7. PRIMECAB M/s SHAKUN POLYMERS
M/s Ravin Cables LIMITED, 501/502,
Limited,302, IVORY TERRACE, R.C. DUTT
Akruti Trade Centre 3rd ROAD,
Floor, ALKAPURI, VADODARA -
Road No,7,MIDC,Marol 390007
Andheri (E) Mumbai-
400093 6. KONARK
M/S SEVRVO CABLE
8. PELEC IND.
43,Sudama Estate, 90/5, MANDIR MARG
B/h,Swastik IND.
Bansidhar Mills, Narol COMPLEX,
Cross HAIDERPUR, NEW
Road,Ahmedabad-382405 DELHI
110052.
FLEXIBLE WIRES &
CABLES/INDUSTIRES WIRES/PVC 7. PRIMECAB
WIRES/CO-AXIAL CABLE, M/s Ravin Cables
SUBMERSIBLE CABLE/ZHFR CABLE Limited,302,
ETC Akruti Trade Centre 3rd
1. BHARAT Floor,
M/s Vardhman Cables & Road No,7,MIDC,Marol
Controls Belgaum Andheri (E) Mumbai-
400093
2. VINAY
M/s. Vinay Electricals, 8. NIKI
18-A, Singh M/s NIKi Cables
Industrial Estate, Bldg. Industries,E/
No. 1, 9 B Panchratna
Rammandir Road, Appt.Opp.
Gorengaon (W), Sunview
Mumbai-40014. Tower,Memnagar
Ahmedabad-52
3. EKTA
M/s Scot innovation Wires &
Cables P.L.195/1/197/1, 9. JAINFLEX
Jharmajri Baddi,Dist Solan

Signature of Contractor 293


M/S Jainflex Cables P.L., 093.
A-
2/1, Sabarmati industrial 15. GEMSCAB
Society, Sabarmati, M/S GEMSCAB IND.LTD.
AHMEDABAD PREM SADAN-11,
RAJENDRA PLACE
10. SIGMA NEW DELHI-110008
M/s MCB Electro
Controles,C- CHAPTER-V FANS
176, 5.1 CEILING FANS & TABLE
Mayapuri industrial FANS
Area, 1. ORPAT
Phase –ii, M/s. Ajanta industrial
New Delhi-110064 Estate,Rajkot
Highway Post Box
11. BENTEX No.115,
M/S Jay Insustires, Bintex Morbi
House, Bhavnagar Road,
Nr. Rajmoti Ind. Rajkot. 2. USHA
M/S USHA
12. DARSHANPLUS INTERNATIONAL LTD
M/S DARSHAN CABLE 1st Floor, Super Market,
INDUSTIRES C/1 135/A Nr.Natraj
PHASE-1, VATVA GIDC Cinema,Ashmram
ESTATE Road,Ahmedbad-
NR PUSHPAK ESTATE, 380009
AHMEDABAD.
3. JILCO
13. INDOASIAN M/S JAIN INDUSTRIAL
M/s indo Asain LIGHTING CORP.B-70/22,
Fusegear DSIDC Complex,
Limited, 203-204, Lawrence Road New Delhi-
Shreedhar 35
Avenue, 11, Sardar
Patel 4. ANCHOR
Colony, Nr. Sardar Patel Anchor Elect. P.Ltd.
Statue, Naranpura, Marathon lnnova C Wing.
Ahmedabad. Opp.G.K.Marg, Lower
Parel [ W ]
14. LEADER Mumbai-400013
M/s. Leader Electrical
P.L., Leader 5. CROMPTON
House, 9-B, Mahal M/s. Crompton Greeves,
Industrial Estate, C.Q. Hube,
P.B.No. 9483, Mahakali 6th Floor, Dr. Annie Besant
Caves Road,
Road, Andheri (E), Worli, Mumbai – 400030.
Mumbai-400

Signature of Contractor 294


6. BAJAJ 2. NOVA
M/s. Bajaj Electricals Limited,
106, 1st 3. EPC
Floor, Sakar-III, Nr. Ashram
Road, 4. REMI
Navrangpura, Ahmedabad-
380014. 5. KHAITAN

7. PHILIPS 6. ORIENT
M/s. Philips Electronics India
Ltd., 7, (B) CATEGORY-II
Justice Chandra Madhab 1. USHA
Road, M/S USHA
Kolkata-700020. INTERNATIONAL
LTD 1st Floor, Super
8. KHAITAN Market,
M/s Khailtan Nr.Natraj
Electrical,101/102, Cinema,Ashmram
Mahakant Complex,Opp.V.S. Road,Ahmedbad-
Hospital,Ashram 380009
Road,Ahmedabad-
380006 2.
CROMPTON
M/s. Crompton
9. DECON Greeves, C.Q.
M/s Decon Lighting,Y- Hube, 6th Floor, Dr.
43,Okhak Phase-II New Annie
Delhi- Besant Road, Worli,
110023 Mumbai –
400030.
10. ORIENT
3. G.E.C.
11. ALMONDARD
4. BAJAJ
12. CINNI M/s. Bajaj Electricals
Limited,
13. REMI 106, 1st Floor, Sakar-
III, Nr.
14. KEDIA Ashram Road,
Navrangpura,
15. NOVA Ahmedabad-380014

16. GEC 5. ALMONARD


.
5.2 EXHAUST FANS,BRACKET CHAPTER-VI
FANS & PEDESTAL FANS
(A) CATEGORY-II 6.4 SMC PRESS MOULDED BOX FOR
1. ANSU STREET
LIGHTS

Signature of Contractor 295


5. KELTRON
1. SINTEX-APPROVED
M/S SINTEX INDUSTRIES 6. RIDER
LTD
KALOL (NORTH GUJARAT) 7. OCLEG
PIN-382721
8.1.1 CAPACITOR
2. EVEREST-APPROVED 1. HAVELL’S
M/S EVEREST ELECTRICALS M/s Havell‟s India
133,PRINCESS Ltd,202-
STREET,GOPAL 205,SHIVALIK II,Nr.
NIWAS,1ST FLOOR,ROOM NO Shivranjani Cross
9/10/11,MUMBAI-400002 Road,
Satelite 132 Ft. Ring
3. ESCO-APPROVED Road,Ahmedabad-
M/S ELECTRO SPARES & CO. 380015
1894/A/1 inside Pade Pole
Gandhi 2. MATRIX
Road Ahmedabad-380001 M/s Matrix Control &
Engineering P.L..E-
AIRCONDITIONERS,WATER 725,DSIDC
COOLERS& WATER HEATERS Industrial
SERVO CONTROLLED VOLTAGE Complex,Narela,Delhi-
STABILIZER & ELECTRONICS 110040
POWER CONDITIONERS
1. GRE 8.2 ON LINE UPS
M/s GRE Electronics,Plot 1. GRE
No.423 G.I.D.C.- M/s GRE Electronics,Plot
II,Dediyasan Mehsana- No.423 G.I.D.C.-
384002 II,Dediyasan Mehsana-
384002
2. GELCO
M/S. GELCO ELECTRONICS 2. SUVIK
P.L., 6,7,8 &16, Amarnath M/S SUVIK ELECTRONICS
Estate, P.L. SECTOR
Nr. Krishna Gopal Estate, NO.28,INDUSTRIAL
Naroda Road, Ahmedabad. ESTATE GANDHINAGAR

3. SUVIK 3. KEPREJ
M/S SUVIK ELECTRONICS P.L. M/S KEPREJ ELECTRONICS
SECTOR NO.28,INDUSTRIAL SECTOR
ESTATE GANDHINAGAR NO.28,INDUSTRIAL
ESTATE GANDHINAGAR
4. KEPREJ
M/S KEPREJ ELECTRONICS 4. KELTRON
SECTOR NO.28,INDUSTRIAL
ESTATE GANDHINAGAR 5. OCLEG

Signature of Contractor 296


M/s.OCLEG M/S. GELCO
CONTROLS,93- ELECTRONICS
94,Amar Estate,B/h Lubi P.L., 6,7,8 &16, Amarnath
Elect.,Memco,Naroda Estate,
Road,Ahmedabad Nr. Krishna Gopal Estate,
Naroda Road, Ahmedabad.
8.3 WATER HEATERS
A. CATEGORY-I
2. CROMPTON
1. BAJAJ M/s. Crompton Greeves,
M/s. Bajaj Electricals C.Q.
Limited, Hube, 6th Floor, Dr. Annie
106, 1st Floor, Sakar- Besant Road, Worli,
III, Nr. Mumbai –
Ashram Road, 400030.
Navrangpura,
Ahmedabad- 3. JYOTI
380014.
B. CATEGORY-III
2. USHA
M/S USHA 1. HAVELL’S
INTERNATIONAL M/s Havell‟s India
LTD 1st Floor, Super Ltd,202-
Market, 205,SHIVALIK II,Nr.
Nr.Natraj Shivranjani Cross Road,
Cinema,Ashmram Satelite 132 Ft. Ring
Road,Ahmedbad- Road,Ahmedabad-
380009 380015

B. CATEGORY-II 2. C &S
1. JILCO M/s. Control &
M/S JAIL INDUSTRIAL Switchgears
LIGHTING Contractors Ltd., 9th
CORP. Floor,
HERITAGE, Nr. Gujarat
2. SPHEREHOT Vidyapith, Ashram Road,
Ahmedabad-380009
3. RECOLD
3. BCH
4. VENUS M/s BCH Electric Limited
93,
CHAPTER-IX City Centre,Nr.Swastik
MOTOR PUMPS Char
9.1 MOTOR PUMP STARTERS&
STARTER Rasta,C.G.Road,Ahmedabad
ACCESSORIES 380009
A. CATEGORY-II
1. GELCO 4. C&S GEWISS

Signature of Contractor 297


M/s. Control &
Switchgears MAKARPURA,VADODARA
Contractors Ltd., 9th
Floor, 4. NIPPEN
HERITAGE, Nr. Gujarat M/s NIPPEN ELECTRICAL
Vidyapith, Ashram Road, INSTRUMENTS CO,12-A,
Ahmedabad-380 009. Joy
Engg.Compound,Marol
5. L&T Maroshi Road, Andheri
M/s L&T House,Ballord (E)
Estate,P.O.Box No.278 Mumbai-59
Mumbai-400001
5. STANDARD
6. Siemens M/s.Standard Electrical
M/s Siemens Ltd Ltd
L.V.Control & 202,205 Shivalik-II N.R.
Distribution Products Shivranjani Cross Road,
Thane Satelite 132 Ft. Ring
Belapur Road,Thane- Road
400601 Ahmedabad-380015

7. ALSTHOM 6. L&T
M/s L&T House,Ballord
9.2 PANNEL ACCESSORIES Estate,P.O.Box No.278
1. C&S GEWISS Mumbai-400001
M/s. Control &
Switchgears 7. OCLEG
Contractors Ltd., 9th M/s.OCLEG CONTROLS,93-
Floor, 94,Amar Estate,B/h Lubi
HERITAGE, Nr. Gujarat Elect.,Memco,Naroda
Vidyapith, Ashram Road, Road,Ahmedabad
Ahmedabad-380 009.
9.3 SINGLE PHASE MONO BLOCK
2. GELCO PUMPS
M/S. GELCO (A) CATEGORY-II
ELECTRONICS 1. AMIT
P.L., 6,7,8 &16, Amarnath M/s. Amit Electro Plast,
Estate, 105, 1st Floor,
Nr. Krishna Gopal Sarvoday Comm. Centre,
Estate, Salapose
Naroda Road, Ahmedabad. Road, Nr. G.P.O.
Ahmedabad – 380001.
3. TRINITY
M/S TRINITY 2. LUBI
ENGG.SYSTEM
3. PRIME
P.L.366/A/12,G.I.D.C.ESTATE
(B) CATEGORY-III

Signature of Contractor 298


1. CROMPTON Road, Nr. G.P.O.
M/s. Crompton Greeves, Ahmedabad –
C.Q. 380001.
Hube, 6th Floor, Dr.
Annie 4. LUBI
Besant Road, Worli,
Mumbai – 5. KIRLOSKAR
400030.
6 CROMPTON
2. KIRLOSKAR M/s. Crompton Greeves,
C.Q.
3. Siemens Hube, 6th Floor, Dr.
M/s Siemens Ltd Annie
L.V.Control & Besant Road, Worli,
Distribution Products Mumbai –
Thane 400030.
Belapur Road,Thane-
400601 9.5 STARTER PANELS
1. GELCO
9.4 OPEN WELL TYPE HORIZONTAL M/S. GELCO
MONO BLOCK PUMPS ELECTRONICS
(A) CATEGORY-I P.L., 6,7,8 &16,
1. PRIME Amarnath Estate,
(B) CATEGORY-II Nr. Krishna Gopal
1. UNEEL Estate,
M/s UNNATI Naroda Road,
INDUSTIRAL Ahmedabad.
COPORATION,D-
61,Diamond 2. SAHIL
Park,G.I.D.C.Nr.Nana M/s SAHIL ELECTRO
Ahmedabad-382330 SYSTEM 163,Vikas
2. AMRUT industrial
M/s Amrit Engineering Estate,Opp Anil Starch
P.L.P.O. Mills,
No.4141,2nd Nr.Vimayojna
Floor,Motilal Hospital,Natan
Centre, Mills Road,Ahmedabad-
Nr.Dinesh Hall,Ashram 380025
Road,
Ahmedabad-3800009 3. HAVELL’S
M/s Havell‟s India
3. AMIT Ltd,202-
M/s. Amit Electro Plast, 205,SHIVALIK II,Nr.
105, 1st Shivranjani Cross
Floor, Road,
Sarvoday Comm. Satelite 132 Ft. Ring
Centre, Road,Ahmedabad-
Salapose 380015

Signature of Contractor 299


M/s Amrit Engineering
4. OCLEG P.L.P.O.
M/s.OCLEG No.4141,2nd Floor,Motilal
CONTROLS,93- Centre,
94,Amar Estate,B/h Lubi Nr.Dinesh Hall,Ashram
Elect.,Memco,Naroda Road,
Road,Ahmedabad Ahmedabad-3800009

5. L&T 3. KSB
M/s L&T House,Ballord 4. KIRLOSKAR
Estate,P.O.Box No.278
Mumbai-400001 5. LUBI.

6. SAMUDRA CHAPTER-X SUBSTATION


M/s Samudra Power EQUIPMENTS
Products, 10.1 (A) APPROVED
Plot No.32 Road No.5/A 1. BIECCO
G.I.D.C M/s BIECOO LAWARIE
Kathawada,Ahmedabad- LIMITED,95,Maker Tower
380415 “F” 9th Floor,Cuffee Parade,
Mumbai-400005
9.6 SUBMERSIBLE PUMPS
(B) CATEGORY-II
(A) CATEGORY-I 1. UNIVERSAL
1. AROMA
M/s ARIHANT PUMPS
PVT. (C ) CATEGORY-III
LTD,Near Ladbi
Nata,Deesa 1. CROMPTON
Highway,Palanpur- M/s. Crompton Greeves,
385001 C.Q.
Hube, 6th Floor, Dr.
2. PLUGA-APPROVED Annie
M/S Shroffs Engineering Besant Road, Worli,
Limited Mumbai –
850/2G.I.D.C.Estate 400030.
Makarpura,
Vadodara-390010 2. L&T
M/s L&T House,Ballord
(B) CATEGORY-III Estate,P.O.Box No.278
1. UNEEL Mumbai-400001
M/s UNNATI INDUSTIRAL
COPORATION,D- 3. KIRLOSKAR
61,Diamond
Park,G.I.D.C.Nr.Nana 4. ALSTOM
Ahmedabad-382330
5. VOLTAMP
2. AMRUT M/s Universal Power xmer Ltd.

Signature of Contractor 300


26/a, 2nd Phase,Peenya Area, Bangalore-560058
industrial. 2. SKP

LIST OF IS CODES

IS CODES

IS Code No. Subject

GENERAL
IS 4082 Stacking & storage of construction materials and components at site –
Recommendations

IS 1200 Method of measurement of building and civil engineering work.(All Parts)


IS 1141 Seasoning of Timber – Code of practice

EARTH WORK
IS 3674 Safety code for excavation work

IS 1498 Classification and identification of soils for general engineering purposes.

IS 1200 (Pt-1) Method of measurement of earth work

IS 1200 (Pt-27) Method of measurement of earth work (by Mechanical Appliances)

Signature of Contractor 301


IS 4081 Safety code for Blasting and related drilling operation

IS 4988 (Part-IV) Excavators

IS 6313 (Pt-II) Anti Termite measures in buildings (pre-constructional)

IS 6313 (Pt-III) Anti Termite measures in buildings for existing buildings

IS 6940 Methods of test for pesticides and their formulations

IS 8944 Chlorpyrifos emulsifiable concentrates

IS 8963 Chlorpyrifos – Technical specifications

IS 12138 Earth moving equipments

MORTARS
IS 269 Specification for 33 grade ordinary Portland cement

IS 455 Specification for Portland slag cement

IS 650 Specification for standard sand for testing of cement

IS 1269 Specification for 53 grade ordinary Portland cement

IS 1542 Specification for sand for plaster

IS 2116 Specification for sand for masonry mortar

IS 2250 Code of practice for preparation and use of masonry Mortar

IS 3025 Method of sampling and test for water

IS 3406 Specification for masonry cement

IS 3812 (Part-I) Specification for flyash for use as pozzolana in cement mortar and
concrete

IS 3812 (Part-II) Specification for flyash for use as admixture in cement mortar and
concrete

IS 8041 Rapid hardening Portland cement

IS 8042 Specification for white cement

IS 8112 Specification for 43 grade ordinary Portland cement

Signature of Contractor 302


IS 1298 Methods of test for determination of free lime in portland cement

IS 6452 High alumina cement for structural use

IS 1489 Portland Pazzolana Cement

CONCRETE WORK
IS 383 Specification for coarse and fine aggregate from natural source for
concrete

IS 303 Coarse and fine aggregates from natural sources for concrete

IS 2430 Methods for sampling of aggregates for concrete

IS 2386 Method of test for aggregates for concrete

(a) Part-I : Particle size and shape


(b) Part-II : Estimation of deleterious materials and organic impurities
(c) Part-III : Specific gravity, density, voids absorption and bulking
(d) Part-IV : Mechanical properties
(e) Part-V : Soundness

IS 2505 General requirements for concrete vibrators – immersion type

IS 2506 General requirements for concrete vibrators – screed board concrete


vibrators

IS 2645 Specification for integral water proofing compounds for cement mortar
and concrete

IS 761 (Part-I) Code of practice for extreme weather concreting (Part-I) recommended
practice for hot weather concreting

IS 7861 (Part-II) Code of practice for extreme weather concreting (Part-II) recommended

IS 9103 Specification for concrete admixtures

IS 460 Test sieves

IS 1607 Methods for dry sieving

IS 1834 Hot applied sealing compounds for jointing concrete

REINFORCED CEMENT CONCRETE WORK

IS 1904 Structural safety of buildings, shallow foundation

IS 1893 Criteria for earthquake resistant design of structures

Signature of Contractor 303


IS 432 (Part-I) Specification for mild steel and medium tensile steel bars and hard drawn
steel wire for concrete reinforcement part-I mild steel and medium tensile
steel bars

IS 432 (part-II) Specification for mild steel and medium tensile steel bars and hard drawn
steel wire for concrete reinforcement part-II hard drawn steel wire

IS 456 Code of practice for plain and reinforced concrete

IS 516 Method of test for strength of concrete

IS 1199 Method of sampling and analysis of concrete

IS 1200 (Part-II) Method of measurement of building and civil engineering work – concrete
work

IS 1200 (Part-V) Method of measurement of building and civil engineering work – concrete
work (Part 5 – Form work)

IS 1566 Specification for hard drawn steel wire fabric for concrete requirement

IS 1599 Method of bend test

IS 1343 Code of practice for Prestressed Concrete

IS 1786 Specification for high strength deformed steel and wires for concrete
reinforcement

IS 1791 Specification for batch type concrete mixes

IS 2502 Code of practice for bending and fixing of bars for concrete reinforcement

IS 2751 Recommended practice for welding of mild steel plain and deformed bars
for reinforced construction

IS 4925 Batch plants specification for concrete batching and mixing plant

IS 4926 Ready – Mixed Concrete

IS 6523 Specification for precast reinforced concrete door, window frames

IS 10262 Recommended guidelines for concrete mix design

IS 13311 (Part-I) Indian standard for non-destructive testing of concrete. Method of test for
ultrasonic pulse velocity
IS 13311 (Part-II) Indian standard for non-destructive testing of concrete. Method of testing
by rebound hammer.

Signature of Contractor 304


IS 3370 Concrete structures for storage of liquids

IS 1568 Wire gauge for general purposes

IS 1139 Hot rolled mild steel and medium tensile steel deformed bars for concrete
reinforcements

IS 2502 Code of practice for bending and fixing of bars for concrete reinforcement

IS 2751 Code of practice for welding of mild steel bars used for reinforced
concrete work

STEEL WORK

IS 226 Structural steel

IS 2062 Steel for general structural purpose

IS 800 Code of practice for use of structural steel in general in steel construction

IS 806 Code of practice for use of steel Tubes in general building construction

IS 816 Code of practice for use of metal arc welding for general construction in
mild steel

IS 818 Code of practice for safety and healthy requirements in electric and gas
welding and cutting operations

IS 822 Code of procedure for inspection of welds

IS 1038 Steel doors, windows and ventilators

IS 1081 Code of practice for fixing and glazing of metal (Steel and aluminium)
doors, windows and ventilators

IS 1161 Steel tubes for structural purposes

IS 1200 (Pt. VIII) Method of measurements of steel work and iron works

IS 1367 Technical supply conditions for threaded steel fasteners

IS 1821 Dimensions for clearances holes for bolts and screws

IS 2074 Ready mixed paint, air drying redoxide zinc chrome priming

IS 4736 Hot – dip zinc coating on mild steel tubes

Signature of Contractor 305


IS 4923 Hollow steel sections for structural use – specification

IS 6248 Metal rolling shutters and rolling grills

IS 7452 Specification for hot rolled steel sections for doors, windows and
ventilators

BRICK WORK

IS 712 Specification for building limes

IS 1077 Common burnt clay building bricks

IS 1200 (Part 3) Method of measurements of brick works

IS 2212 Code of practice for brick work (1st Revision)

IS 3495 Method of test for burnt clay building bricks

IS 5454 Methods of sampling of clay building bricks

IS 13757 Specification of burnt clay fly ash bricks

IS 2691 Burnt clay facing bricks


MARBLE WORK

IS 1122 Method of test for determination of true specific gravity of natural building
stones

IS 1124 Method of test for determination of water absorption, apparent specific


gravity and porosity of natural building stones

IS 1130 Marble (blocks, slabs and tiles)

IS 4101 (Part-I) Code of practice for external facing and veneers: Stone facing

IS 14223 (Part-I) Polished Building Stones ( Part-I) Granite

WOOD WORK AND P.V.C. WORK

IS 204 (Part-I) Specification for tower bolts (ferrous bolt)

IS 208 Specification for door handles

IS 287 Recommendations for maximum permissible moisture contents of timber


used for different purpose

IS 303 Specification for plywood for general purposes

Signature of Contractor 306


IS 401 Code of practice for preservation of timber

IS 453 Specification for double acting spring hinge

IS 710 Specifications for Marine Plywood

IS 1003 (Part-I) Specification for timber paneled and glazed shutter Part-I (Door shutters)

IS 1003 (Part-II) Specification for timber paneled and glazed shutter Part-II (Window and
ventilator shutters)

IS 1200 Part-XIV Method of measurement of building and civil engg. Work glazing

IS 1200 Part-XII Wood work and joinery

IS 1328 Specification for veneered decorative plywood

IS 1341 Specification for steel butt hinges

IS 1659 Specification for block boards

IS 1823 Specification for floor door stopper

IS 1868 Specification for anodic coating on aluminium and its alloy

IS 2046 -do- Decorative thermosetting synthetic resin bonded laminated sheet

IS 2095 Specification for gypsum plaster board

IS 2202 (Pt I) Specification for wooden flush door shutter, solid core type (plywood face
panels)

IS 2209 Specification for mortice lock (Vertical Type)

IS 2547 Specification for gypsum plaster

IS 3097 Specification for veneered particle board

IS 3564 Specification for door closer (hydraulically regulated)

IS 3847 Specification for mortice night latch

IS 5930 Specification for mortice latch

IS 7196 Specification for hold fast

IS 8756 Specification for mortice ball catch for use in wooden almirah

Signature of Contractor 307


IS 9308 (Part-II) Specification for mechanically extracted coir fibres (Mattress coir fibres)

IS 12817 Specification for stainless steel butt hinges

IS 12823 Specification for wood products – Prelaminated particle Boards

IS 14900 Specifications for transparent float glass

IS 4021 Timber door, windows and ventilator frames.

IS 2191 Wooden flush door shutters (cellular and hollow core type)
FLOORING

IS 1200 (Part-XI) Method of measurement of Building and Civil Engineering work (Part 11)
paving, floor finishes, dado and skirting

IS 1237-Edition 2.3 Specification for cement concrete flooring tiles

IS 1443 Code of practice for laying and finishing of cement concrete flooring tiles

IS 2114 Code of practice for laying in-situ terrazzo floor finish

IS 3622 Specification for sand stone (Slab & Tiles)

IS 4457 Acid and / or alkali Resistant tiles

IS 5318 Code of practice for laying of hard wood parquet and wood block floors

IS 5766 Code of practice for laying of burnt clay brick floor

IS 13630 (Part-1 to Methods of Testing for ceramic tiles


15)

IS 13712 Specification for ceramic tiles, definition, classification characteristic and


marking

IS 15622 Specification for pressed ceramic tile.


ROOFING

IS 277 Galvanised steel sheets (Plain and corrugated)

IS 651 Glazed stoneware pipes and fittings

IS 1200 (Pt IX) Method of measurements of building and civil engineering work : Part-9
Roof covering (including cladding)

IS 1200 (Pt X) Method of measurements of building and civil engineering work : Part-10

Signature of Contractor 308


ceiling and lining

IS 2095 (Pt-1) Gypsum plaster boards (Pt. 1) plain Gypsum plaster boards

IS 2935 Specification for flat transparent sheet glass

IS 459 Corrugated and semi corrugated asbestos cement sheet

FINISHING WORKS

IS 1542 Sand for plaster

IS 1661 Code of practice for cement and cement-lime plaster finishes on walls and
Ceilings

IS 1625 Code of practice for preparation and use of lime mortar in buildings

IS 2250 Code of practice for preparation and use of masonry mortars

IS 712 Building limes

IS 1635 Code of practice for field slacking of lime and preparation of putty.

IS 427 Distemper, dry colour as required

IS 428 Distemper, oil emulsion, colour as required

IS 6278 Code of practice for white washing and colour washing

IS 106 Ready mixed paint, brushing, priming for enamels for use on wood.

IS 102 Ready mixed paint, brushing, red lead, non- setting, priming

IS 123 Ready mixed paint, brushing, finishing, semi-gloss, for general purposes

IS 1477 Code of practice for painting of ferrous metals in buildings

IS 2074 Ready mixed paint, red oxide-zinc chrome priming

IS 2339 Aluminium paint for general purposes in dual container

IS 2932 Enamel, synthetic, exterior, type 1

(a) under coating,

(b) finishing, colour as required

IS 137 Specification for ready mixed paint, brushing, matt or eggshell flat

Signature of Contractor 309


finishing interior to Indian Standard colour as required

IS 1131 Specification for enamel, interior

(a) under coating


(b) finishing.
IS 129 Specification for ready mixed paint, brushing, grey filler for enamel for use
over primers

IS 533 Specification for gum spirit of turpentine (oil of turpentine)

IS 101 Methods of tests for ready, mixed paint, & enamels

IS 124 Specification for ready mixed paint, brushing finishing semi glossy for

(Part I) general purposes

IS 2933 Enamel, Exterior

(a) Under Coating


(b) Finishing
IS 5410 Cement Paint

IS 5411 Plastic emulsion, Paint Part- I for interior use

IS 419 Specifications for putty for use in window frames

VARNISHING & POLISHING

IS 337 Varnish, finishing, interior

IS 338 Varnish, undercoating, exterior natural resin

IS 339 Varnish, undercoating, exterior synthetic resin

IS 340 Varnish, mixing

IS 345 Wood filler, transparent liquid

IS 346 Varnish, spirit, clear, hard

IS 347 Varnish, shellac, for general purposes

IS 348 French polish

IS 349 Lacquer, cellulose clear


ROAD WORK

Signature of Contractor 310


IS 164 Ready mixed paint for road marking

IS 278 Specification for galvanized steel barbed wire for fencing

IS 1838 (Pt.1) Specification for performed filters for expansion joint in concrete
pavements and structures (non extruding and resilient type / bitumen
impregnated fibre)

IS 73 Paving bitumen with bitumen felts

IS 73-1992 Specification for paving bitumen

IS 1203 Method of testing tar and bituminous material Determination of


penetration

WATER SUPPLY, SANITORY INSTALLATIONS & DRAINAGE

IS 771 (Pt.1) Specification for glazed fire clay sanitary appliances : part 1: General
requirements

IS 1703 Water fittings – copper alloy float valves (horizontal plunger type) –
Specification

IS 1729 Cast iron / Ductile iron Drainage Pipes and pipe fittings for Over ground
non-pressure pipe line Socket and Spigot Series

IS 1795 Specification for pillar taps for water supply purposes

IS 2326 Specification for Automatic Flushing Cisterns for Urinals (Other than plastic
cisterns)

IS 2548 (Part-1) Plastic seats and covers for water closets Part 1 : Thermo set seats and
covers – Specifications

IS 2548 (Part-2) Plastic seats and covers for water closets Part 2 : Thermoplastic seats and
covers – Specifications

IS 2556 Vitreous sanitary appliances (vitreous chine) – Specifications

IS 2556 (Part-1) Part-1: General requirements

IS 2556 (Part-2) Paart-2 : Specific requirements of wash-down water closets

IS 2556 (Part-4) Part-4 : Specific requirements of wash basins

IS 2556 (Part-6) Part-6 : Specific requirements of Urinals & Partitions plates

Signature of Contractor 311


IS 2556 (Part-7) Part-7 : Specific requirements of accessories for sanitary appliances

IS 2963 Specification for copper alloy waste fittings for wash basins and sinks

IS 3076 Specification for low density polyethylene pipes for potable water supplies

IS 4827 Specification for electroplated coating of nickel and chromium on copper


and copper alloys

IS 4984 Specification for high density polyethylene pipes for potable water supplies

IS 4985 Unplasticised PVC pipes for potable water supply – Specifications

IS 7231 Plastic flushing cisterns for water closets and urinals – Specifications

IS 13983 Stainless steel sinks for domestic purposes – Specifications

IS 774 Specification for flushing cistern for water closets and urinals

IS 775 Specification for cast iron brackets and supports for wash basins and sink.

IS 778 Specification for cast copper alloy gate and check valves for water works.

IS 651 Specification for salt glazed stoneware pipes and fittings.

IS 3597 Method of test for concrete pipes

IS 1239 Mild steel tubes and tubular

IS 1711 Self closing taps

IS 1726 Cast iron manhole covers and frames intended for use in drainage works

IS 1742 Code of practice for building drainage

IS 2065 Code of practice for water supply in buildings

IS 2470 Code of practice for design and construction of septic tank

IS 2693 Non-ferrous waste fittings for wash basins and sink

IS 4127 Code of practice for laying of glazed stoneware pipes

IS 4346 Washers for water taps for cold water services

IS 778 Gun metal gate, globe and check valves for water services

Signature of Contractor 312


IS 7634 Laying and jointing for polythene pipes and PVC pipes (Part I to III)

IS 8008 Part I Specification for injection Moulded HDPE fittings for potable to IV)
water supplies

IS 3844 Code of practice for installation of internal fire hydrants in multi storey
buildings

IS 780 Specification for sluice valves for water works purposes (50 to 300 mm
size)

IS 781 Specification for cast copper alloy screw down bib taps and stop valves for
water services

IS 782 Specification for caulking lead

IS 909 Underground fire hydrant, sluice valve type – Specification

IS 2692 Ferrules for water services – Specification

IS 15450 PE-AL-PE Pipes for hot and cold water supplies – Specifications

IS 15778 Chlorinated Polyvinyl Chloride (CPVC) pipes for potable hot and cold water
distribution supplies – Specifications

IS 1230 Cast iron rain water pipes and fittings

IS 1626 Asbestos cement building pipes, gutters and fittings (Spigot and
socket type)

IS 2527 Code of practice for fixing rainwater gutters and downpipes for roof
drainage

IS 458 Pre-cast concrete pipes (with and without reinforcement)

IS 783 Code of practice for laying concrete pipes

IS 1728 Specification for Cast Iron Manhole Covers and Frames

IS 4127 Code of practice for Laying of Glazed Stone Ware Pipes

IS 12592 Pre-cast Concrete Manhole Covers and Frames-Specifications

IS 5382 Specification for rubber sealing rings for gas mains, water mains and
sewers

IS 13592 Unplasticised polyvinyl chloride (UPVC) pipes for soil and Waste discharge
system for inside and outside building

Signature of Contractor 313


PILE WORK

IS 1200 (Part 23) Method of measurement of building and Civil Engineering works – Piling

IS 2911 (Part 3) Code of practice for design and Construction of pile foundation under
reamed piles

IS 5112 Safety Code for piling and other deep foundations

IS 14362 Pile boring equipments. General requirements

ALUMINIUM WORK

IS 733 Wrought Aluminium Alloys, Bars, Rods and Sections (For General
Engineering Purposes) – Specification

IS 737 Wrought Aluminium and aluminium alloy sheet and strip for general
engineering purposes – Specification

IS 1285 Wrought Aluminium and Aluminum Alloy, Extruded Round Tube and
Hollow sections (for General Engineering Purposes) – Specification

IS 1868 Anodic coating on Aluminium and its alloy – Specification

IS 1948 Specification for Aluminium Doors, Windows and Ventilators

IS 5523 Method of testing anodic coating on aluminum and its alloys

IS 6012 Measurement of coating thickness by Eddy Current Method

IS 6315 Floor springs (Hydraulic regulated) for heavy doors – Specifications

IS 6477 Dimensions of extruded hollow section and tolerances

IS 14900 Transparent Float Glass – Specifications

WATR PROOFING TREATMENT

IS 3370 (Part 1) Code of practice for concrete structures for the storage of liquid : Part-1
General Requirements

Signature of Contractor 314


QUALITY ASSURANCE PLAN
Quality Assurance Plan :

I The contractors shall state and submit the quality policy statement of his organization. The
contractor shall submit Quality Assurance Plan, so that the properties and characteristics of the
structures planned are in harmony and consistent with the requirements and assumptions made during
planning and designing. The quality plan should aim at achieving and fulfilling desired strength,
serviceability, and long term durability so as to lower the over all life cycle cost.

II The Quality Assurance Plan should broadly consists of the following:

1) Technical Matters.
2) Organizational Matters.

III The Technical Matters shall help in achieving :

a) Use of adequate and specified materials, their evaluation and selection procedures.
b) Proper workmanship for execution of works.

IV The technical aspects shall take care of some basic documentation like:

1) Test reports and manufacturer‟s certificates for materials, concrete mix designs etc.
2) Pour cards for site organization and clearance for concrete placement (For concrete)
3) Record of site inspection of workmanship and field tests etc.
4) Non confirmation reports, change orders etc.
5) Quality control charts.

V The organization measures should broadly include.

Signature of Contractor 315


1) Quality control engineer with adequate team to monitor the quality aspects.
2) The quality assurance plan shall be decentralised to individuals plan, which will fit into general
assurance Plan.
3) Defining the task and responsibility of each member of the team.
4) Adequate documentation of the construction process.

VI Quality Audit:

This would be for the following and shall take care of :

a) For inputs :
Materials,workmanship,curing, measurements, use of proper technology ,
construction equipments etc.

b) For outputs :
Generation of documentation necessary to provide objective evidence of achievement of quality
objectives.
1 Documentation of evaluations and findings.
2 Regular periodical review of the quality assurance programme.
3 Requirements for corrective action and response.
VII SITE ORGANIZATION :

Maintaining the Quality of works during the execution will be the main aim of the contractors and
hence, Quality Assurance/Quality control Team shall be on their toes to look after the quality aspect.
The Contractor shall maintain a full fledged laboratory with following equipments for exercising the
quality control in works at the site.

1. Concrete Cube Testing Machine.


2. Sets of Concrete Cube Moulds.
3. Sets of Cement Mortar Cube Moulds.
4. Slump Cone with Scale.
5. Rapid Moisture Master.
6. Weighing Balance (Scientific).
7. Weighing Balance (Conventional).
8. Set of IS Sieves for Course Aggregates.
9. Set of IS Sieves for fine Aggregates.
10. Vernier Calipers.
11. Sets of leveling instrument, level staff & tripod.
12. Theodolite with tripod.
13. Set of Calibrated glass jars.
14. Gauge Measuring Disc.
QUALITY CONTROL MANAGEMENT PLAN & DETAILS OF TESTING EQUIPMENT

(I) QUALITY CONTROL IN CONCRETING :


(a) Slump Test
(b) Cubes for Compressive test

Signature of Contractor 316


(c) Modification of mixer blocks at site to ensure better mixing
(d) Tests for sand - Bulkage, moisture & silt content etc.
(e) Test for Cement- Initial & Final setting time, specific gravity, compressive
strength.
(f) Test for Aggregate - Moisture content etc.
(g) Controlling water cement ration.

(II) LIST OF EQUIPMENTS (IN ONE LABORATORY)


(1) Cube Testing Machine - 1 No.
(2) Rapid Moisture Meter - 1 No.
(3) Weight Balance - 1 No.
(4) Weights from 5 gm to 5 kg. - 1 Set
(5) Sieve Set ( 40 mm, 20, 10,
(4.75, 2 No., 150, 90, 75, 63) - 1 Set
(6) "VICAT" apparatus with needles
(10 mm, 2 mm & Fancy Setting Neelde) - 1 Set
(7) Calipers (measuring) - 1 No.
(8) Sp. Gvty. Bottle - 2 No.
(9) Hand Gloves - 1 Set
(10) Cube Moulds - 20 Nos.
(11) Slump Cone. - 2 No.
(12) Cement mortar comp. - 4 No.

Signature of Contractor 317


SIEVE ANALYSIS OF SAND
Source : Sampled By :
Date and Time of Test Conducted
Sampling : ______________________ By : _______________________
Sr. Sample Cumulative % Retained on each in Sieve No. Passing F.M.
No. No. 150 Actua
l
4.75 2.36 118 600 300 150 MICRONS
MH MH MH MICRONS MICRONS MICRONS

Grading :
Sr. Sample Percentage Passing Each Sieve Size
No. No. Remar
ks
10.00 4.75 2.36 118 600 300 150
MH MH MH MH MICRONS MICRON MICRON
S S

SAMPLED BY TESTED BY
Silt Content = (Wt. of Material Passing 75 micron Sieve /Original wt. x 100%)
IN % = _________ % (OK IF (3.0%))

Signature of Contractor 318


ROUTINE TESTING OF CEMENT
( COMPRESSIVE STRENGTH NORMAL CONSISTENCY ETC.)

Sampl Locatio Stac Typ Date of Date Ambe Nominal


e No. n k e Samplin of nt Consiste Compressive Strength Remar
No. g Temp ncy Kg/cm ks
.
Casi Durin Percent 1 2 3 7 28
ng g Da Das Das Day Da
Castin y y y s ys
g
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Note : All tests are conducted at Temperature 27 C + 2 C

SAMPLED AT TESTED BY :

CONTRACTOR P.M.C.

ACCEPTANCE OF CONCRETE QUALITY

1. Grider No.
2. Av. Cube Strength : XA =_________ ( Mean of the Group of 4 non-overlapping
consecutive test results)
3. No. of Cube : n =
4. FCK : =
5. Standard Deviation : SD

Signature of Contractor 319


6. (FCK-0.825 x SD) : A=
7. FCK +4 : B=
8. Greater of 6 & 7 above : C=
9. Minimum Cube Strength : D = FCK – 4
10. No. of cube having Cube : E=
Strength out of 4
as described above= D

10. Whether E =< 1 Yes/No


11. Whether XA >= C Yes/No
12. Concrete quality :

Accepted If reply to 10 & 11 is Yes


Rejected If reply to 10 or 11 is no.

CONTRACTOR PMC

CONCRETE LABORATORY
LABORATORY MIX DESIGN

1. OBJECT MIX REFERENCE NO.


2. LOCATION OF CONCRETE BE POURED
3. BASIC REQUIREMENT OF CONCRETE

CONSISTEN WATER DESIGEND WATER CEMENT EXPECTED REMARKS


CY (SLUM) CONTENT STRENGTH CEMENT CONTENT SAND
MM FOR AT 28 DAYS RATIO FOR COL.2 CONTENT
REQUIRED KG/SQ. DESIGNED /COL. 4 FOR
SLUMP CU.M. STRENGTH (KG/CU.M) WORKABILIT
KG/CU.M. Y (PERVENT)
1 2 3 4 5 6 7

Signature of Contractor 320


4. MIX CALCUATION DENSITY KG/CU.M.
ASSUME ONE CU.M. OF CONCRETE CEMENT =
(A) VOLUME OF EXPECTED AIR CU.M.
(B) VOLUME OF SOLID CONCRETE (1-4) CU.M

WT. OF CEMENT
(C) VOLUME OF CEMENT = ------------------------ CU.M.
DENSITY OF CEMENT

WT. OF CEMENT
(D) VOLUME OF WATER = ------------------------ CU.M.
DENSITY OF CEMENT

(E) VOLUME OF ALL IN AGG. CU.M.


(B-(C+D))
(F) VOLUME OF SAND = E x % SAND CU.M.
(G) VOLUME OF AGG. = E -F CU.M.
(I) WT. OF AGG. = G x DENSITY OF AGG. CU.M.
W : C : S : AGG.

MIX RATION BY WT.

Signature of Contractor 321


NAME OF AGENCY :
NAME OF WORK : NAME OF P.M.C. :
TEST RESULT OF FINE AGGREGATE
Sam Descri Date Passi Deleterious Materials Total Specif Absorp Soundness loss Orga Mortar Rema
p. p-tion of Locati Type ng (Present) of ic tion after 5 cycle nic Strength rk
No. of Sampli on & 75 Delet Gravit Presen Impu
ng a- y t -
Test Sour micr Shal Coal Clay Other rious (SSD) Sodiu Magnes rities Un Was
ce on e & Lu Deletari Mater m ium wash hed
Ligni mp ous ial Sulph Sulphat ed Sam
te Material ate e Sam ple
ple

SAMPLED BY TESTED BY
CONTRACTOR P.M.C

NAME OF AGENCY :

NAME OF WORK :
NAME OF P.M.C. :
Signature of Contractor 322
Test Form No. 2
TESTING OF CEMENT CONCRETE CUBES
Sr. Date of Gradation Location Total Age Weight Observed Comp. Strength Lab. Action Signature
No. casting of where Qyt. of of Dimension Ref. taken
Concrete Concrete Concrete Cube of Cube
Date of is used laid 1st Average Final Averag Engg./ Contracto
testing during test kg/cm2 Test e P.M.C. r
the day result result kg/cm2

Note : The cubes must be tested on 7th and 28th days of casting and results entered in column No. 8 and 10 as per 1st or
final test.
Contractor P.M.C.

Signature of Contractor 323


NAME
OF AGENCY :
NAME OF WORK : NAME
OF P.M.C. :
Test Form No. 3
CONCRETE SLUMP TEST
Sr. Date of Gradation Location Ht. of cone Ht. of Conc. Slump Shape of Water Action Signature Remarks
No. testing of where with Cone. sample after observed in Conc. after Cement taken
Concrete Concrete sample removal of mm (5-6) removal of ratio
is used cone cone
1) Engg. Contr
2) / actor
3) P.M.C
.

Contractor P.M.C.

Signature of Contractor 324


NAME OF AGENCY :
NAME OF WORK : NAME OF P.M.C. :

Test Form No. 4


TESTING OF SAND-SILT CONTENTS
Sr. Date of Source of Ht. silt layer Ht. of Sand % Silt Action Signature Remarks
No. test Sand in Jar 'X' Layer in jar content taken
mm 'Y' mm X/Y x 100
Engg./ Contractor
P.M.C.

Contractor P.M.C.

Signature of Contractor 325


NAME
OF AGENCY :
NAME OF WORK : NAME
OF P.M.C. :
Test Form No. 6
SIEVE ANALYSIS OF METAL (COARSE AGGREGATES)
Sr. Date Total Wt. Cum. wt. retained on sieve Fineness Moisture Specific Water Lab. Action Signature Remarks
No. of of in mm modulus content gravity absorption ref taken
test Sample
80 40 20 10 4.75 Engg./ Contractor
P.M.C.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Contractor P.M.C.

Signature of Contractor 326


NAME OF AGENCY :
NAME OF WORK : NAME OF P.M.C. :
Test Form No. 7
SIEVE ANALYSIS OF SAND (FINE AGGREGATES)
Sr. Date Total Wt. Cum. wt. retained on sieve Finenes Moistur Specifi Water Lab. Action Signature Remark
No. of of in mm s e c absorpt ref Taken s
test Sample modulu content gravity ion
s
10 4.7 2.3 1.1 0.6 0.3 0.1 Engg./ Contractor
5 6 8 0 0 5 P.M.C.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Contractor P.M.C.

Signature of Contractor 327


NAME OF
AGENCY :
NAME OF WORK : NAME OF
P.M.C. :
Test Form No. 8
TEST OF CEMENT

Sr. Sample Date Fineness Soundness Setting time Compressive Lab. Action Signature Remarks
No. identification No. of strength ref. taken
include. casting in kg/cm2
name of factory Initial Final 3 7 28 Engg./ Contractor
lot No. etc. in in days days days P.M.C.
min. min.

Contractor P.M.C.

Signature of Contractor 328


NAME OF AGENCY :
NAME OF WORK : NAME OF P.M.C. :

Test Form No. 9


TESTING OF STEEL
Sr. Test No. Qty. Date Dia & type Ultimate Yield % Cold Lab. Action Signature Remarks
No. & details received of of Bar tensile strees Elongation Bend ref. taken
of sample till date test mild/ Tor strees in in Test
of test mm. kg/Sq.mm kg/Sq.mm
.
Engg./ Contractor
P.M.C.

Contractor P.M.C.

Signature of Contractor 329


POUR CARD
NAME OF STRUCTURE / ACTIVITY : ____________________________________________
LOCATION OF WORK : ____________________________________________
DATE OF WORK : _____________ QUANITY OF CONCRETE : ____________________
CEMENT BAGS REQUIRED :__________________
MIX TO BE USED : __________________________
Sr. Item Contractor Checked by Remarks
No. Consultants
WHETHER THE FOLLOWING CHECKED
1. Aggregates
2. Centering
3. Shuttering
a. Oiling
b. Leveling
c. Filing gaps
4. Reinforcement Checking
a. Spacing & alignment
b. Size & spacing of stirrups
c. Cover Block& Chairs
d. Clearing
e. Binding/ Wire/ Laps/ Dowels/ Expansion
joints

5. Electrical Conduits etc.


6. Cat walk
7. Slump cone & Cube Moulds
8. Vibrator & Tamping Tools & Mixer Machine
9. Man power arrangements
10. Water arrangements including for curing
11. Final O.K.