INDUSTRIAL SPECIFICATION GRADE


LOCKING DEVICES
Overview___________________________J1
15 Amp Devices __________________J2–J4

Devices 15 Amp Cord Sets ___________________J2


20 Amp Devices __________________J4–J9
30 Amp Devices _________________J9–J13
Wetguard™ Devices
Industrial Specification Grade 15 Amp _________________________J14
15 Amp Locking Cord Sets _________J14
Leviton’s Industrial Specification Grade Locking Devices 20 Amp _____________________J14–J15
are built to provide unparalleled quality and superior 30 Amp _________________________J16
Non-NEMA Devices
performance in the most severe industrial settings. The 15 & 20 Amp _____________________J17
Leviton line includes a comprehensive selection of 30 & 50 Amp _____________________J18
rugged plugs and connectors, Wetguard plugs and 50 Amp Non-NEMA “California Style” CS
connectors for water and moisture resistance, flanged Devices ___________________________J19
inlets and outlets, California-style devices, midget locking Weather-Resistant Boots ____________J20
Power-Interrupting Devices __________J21
devices, power-interrupting devices and non-NEMA
Midget Devices_____________________J22
devices. Our V-0-MAX™ Locking Flush Receptacles are Combination Locking and
designed for maximum performance and feature a UL 94 Straight Blade Devices ______________J23
V-0 Flammability Rating, the best flammability rating for a Integrated Inlets and Outlets
locking flush receptacle available today. with Weather-Resistant Covers _______J23

S E C T I O N J
Locking Devices
Leviton’s Industrial Specification
Grade Locking Devices are built to
provide unparalleled quality and
superior performance in the most
severe industrial settings. The
Locking Devices line represents a
broad selection of plugs and con-
nectors, locking receptacles,
flanged inlets and outlets, California-
style devices, midget locking
devices, power interrupting devices,
and non-NEMA devices. Leviton
combines the best materials avail-
able with superior production stan-
dards to produce a broad selection
of Locking Devices of unmatched
flexibility and dependability.
Features and Benefits
■ Uncompromising industrial-grade
quality for superior performance
and long service life
■ All industrial locking devices
feature heavy-duty, impact-resistant
construction
■ Plugs and connectors accept wide
range of conductors
■ Terminals clearly identified on all
devices to speed and simplify wiring
■ Backed by a Limited 10-Year
Warranty

Locking Devices for the Entire Spectrum of Industrial Applications

Locking Plugs and V-0-MAX™ Locking Flush Flanged Inlets and Outlets
Connectors Receptacles
Heavy-duty construction Engineered for Built to endure hard use
for top performance in maximum perfor- with rugged nylon flanges
the environmental mance with a UL 94 that assure a smooth,
extremes of grueling V-0 Flammability flush fit and outstanding
industrial settings. Rating. resistance to cracking and
breaking.

Cat. No. 4720-C Cat. No. 2610 Cat. No. 2336


and 4579-C

Non-NEMA Locking Wetguard™ Midget Locking Devices Weather Resistant


Devices Specifically developed Boots
Provided in selected for wet or damp ML1, ML2 and ML3 Feature triple seal
20A and 30A versions locations. EPTR ther- Locking devices cover- action to protect
and a very broad moplastic rubber body ing the entire spectrum locking plugs and
range of 50A devices. and rugged design of industrial applica- connectors from the
resists water, acids, tions where restrained harmful effects of dirt
alkalies, grease, oils space considerations and moisture in
and solvents. are a factor. harsh operations.
Cat. No. 7411-C Cat. No. 24W47 Cat. No. ML1-C Cat. No. 6034

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World
J1
Locking Devices

15 AMP Locking Devices


15 AMP 125V 2-Pole 3-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Dustguard™ Locking Plug, 2447 .240–.655 12–18
High Visibility Yellow EPTR Body
Dustguard™ Locking Connector, 2547 .240–.655 12–18
High Visibility Yellow EPTR Body
Duplex Flush Receptacle, 4700
Self Grounding, Back and Side Wired
Duplex Flush Receptacle w/2 Hot 4702-IIR
Feeds and 1 Neutral Return, Self
4720-C
Grounding, Back and Side Wired
Duplex Flush Receptacle w/Split Feed — 4703-IIR
2 Hot Feeds and 2 Neutral Returns,
Self Grounding, Back and Side Wired
Duplex Flush Receptacle, 4700-IG
Islolated Ground, Back and Side Wired
W

Single Flush Receptacle 4710** L5-15R


Single Flush Receptacle, w/Short Strap 4710-SS G

Single Flush Receptacle, 4710-IG** W

Isolated Ground L5-15P


G

Single Flush Receptacle, 4710-SIG


Isolated Ground, w/Short Strap
Locking Flanged Outlet 4715-C
Locking Flanged Inlet 4716-C
Locking Plug, Black Nylon Body 4720-C .245–.700 10–18 2547
Angle Locking Plug, Black Nylon Body 4720-CA .245–.700 10–18
Locking Plug, All Black Nylon for 4720-CB .245–.700 10–18
Stage and Studio
SPECIFICATIONS & FEATURES
Locking Plug, Yellow Nylon Body 4720-CY .245–.700 10–18
• Locking Receptacles feature a complete
Locking Connector, Black Nylon Body 4729-C .245–.700 10–18 range of ratings and NEMA configurations,
including isolated ground
Locking Connector, All Black Nylon 4729-CB .245–.700 10–18
for Stage and Studio • Locking Plugs and Connectors feature heavy-
duty construction for top performance in the
Locking Connector, Yellow Nylon Body 4729-CY .245–.700 10–18 environmental extremes of grueling industrial
settings.
• Flanged Inlets and Outlets are built to endure
Factory-Assembled Cord Sets hard use with rugged nylon flanges that
15 AMP 125V 2-Pole 3-Wire Grounding assure a smooth, flush fit and outstanding
resistance to cracking and breaking
DESCRIPTION LENGTH CAT. NO. CAT. NO. NEMA Dustguard
14/3 SOOW 12/3 SOOW CONFIG. • IEC IP44 Rated
Yellow Cord, B & W Devices 25' IL515-43A IL515-23A W • Developed to withstand dusty and dirty envi-
L5-15R ronments, cracking and fading, temperature
G extremes
Yellow Cord, B & W Devices 50' IL515-43B IL515-23B
• Rugged wiring modules have high perfor-
W
mance single-piece brass triple-wipe con-
Yellow Cord, B & W Devices 100' IL515-43C IL515-23C L5-15P tacts, solid brass plug blades
G

• Self centering cord clamp accepts wide range


of conductors, 18-3 SVT to 10-3SO
**Uses stainless steel wallplate, Cat. No. 84004-40. For additional wallplate selections, please see Section G
For Corrosion Resistant Locking Devices, please check pages K2–K5. TESTING & CODE COMPLIANCE
Weather-Resistant Boots for 15A Locking Plugs and Connectors are listed on page J20
• All receptacles, plugs, connectors, inlets and
All devices are UL Listed and CSA certified. outlets are designed to meet NEMA WD-6,
and ANSI C-73, and to meet/exceed UL 498
standards
• UL Fed. Spec. Listed WC-596 (File #13393 –
Cat. Nos. 2447, 2547, 4716, 4720, 4729; File
Ø 1.39 (35.3 mm)

#13399 – Cat. Nos. 4700, 4710, 4715)


• CSA Certified (File #LR-406)
• NOM Certified (#057)
• Backed by a Lifetime Warranty

MATERIAL CHARACTERISTICS
Environmental: Flammability per UL94 or CSA
C22/06 Requirements
Ø 1.53 (38.9 mm) 1.98 (50.4 mm) Operating Temperature: -40°C to 60°C

LOCKING PLUG
Cat. No. 4720-C

For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World
J2
Locking Devices

15 AMP Locking Devices


15 AMP 250V 2-Pole 3-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Duplex Flush Receptacle, Self 4550
Grounding, Back and Side Wired
Duplex Flush Receptacle, Isolated 4550-IG
Ground, Back and Side Wired
Single Flush Receptacle 4560**
Single Flush Receptacle, w/Short Strap 4560-SS
Single Flush Receptacle, 4560-IG** X

Isolated Ground L6-15R G


4570-CA Y

Single Flush Receptacle, Isolated 4560-SIG


Ground, w/Short Strap X

L6-15P G

Locking Plug, Black Nylon Body 4570-C .245–.700 10–18 Y

Angle Locking Plug, Black Nylon Body 4570-CA .245–.700 10–18


Locking Plug, Yellow Nylon Body 4570-CY .245–.700 10–18
Locking Connector, Black Nylon Body 4579-C .245–.700 10–18
Locking Connector, Yellow Nylon Body 4579-CY .245–.700 10–18
Locking Flanged Outlet 4585-C
Locking Flanged Inlet 4586-C

15 AMP 277V 2-Pole 3-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
4579-C Duplex Flush Receptacle, Self 4750
Grounding, Back and Side Wired
Duplex Flush Receptacle, Islolated 4570-IG
Ground, Back and Side Wired
SPECIFICATIONS & FEATURES Single Flush Receptacle 4760**
• Locking Receptacles feature a complete Single Flush Receptacle, w/Short Strap 4760-SS
range of ratings and NEMA configurations,
including isolated ground and non-grounding Single Flush Receptacle, 4760-IG** W
G
• Locking Plugs and Connectors feature heavy- Isolated Ground L7-15R
duty construction for top performance in the
environmental extremes of grueling industrial Single Flush Receptacle, Isolated 4760-SIG
settings Ground, w/Short Strap W
G

• Flanged Inlets and Outlets are built to endure L7-15P


hard use with rugged nylon flanges that Locking Plug, Black Nylon Body 4770-C .245–.700 10–18
assure a smooth, flush fit and outstanding Angle Locking Plug, Black Nylon Body 4770-CA .245–.700 10–18
resistance to cracking and breaking
Locking Plug, Yellow Nylon Body 4770-CY .245–.700 10–18
TESTING & CODE COMPLIANCE Locking Connector, Black Nylon Body 4779-C .245–.700 10–18
• All receptacles, plugs, connectors, inlets and
outlets are designed to meet NEMA WD-6, Locking Connector, Yellow Nylon Body 4779-CY .245–.700 10–18
and ANSI C-73, and to meet/exceed UL 498
standards Locking Flanged Outlet 4785-C
• UL Fed Spec. Listed WC-596 (File #E-13399 Locking Flanged Inlet 4786-C
— Cat. Nos. 4550, 4560,4585-C, 4750,4760,
4785-C; File #E-13393 — Cat. Nos. 4570, **Uses stainless steel wallplate, Cat. No. 84004-40. For additional wallplate selections, please see Section G.
4579, 4586-C, 4770, 4779, 4786-C) For Corrosion Resistant Locking Devices, please check pages K2–K5
• CSA Certified (File #LR-406) Weather-Resistant Boots for 15A Locking Plugs and Connectors are listed on page J20
• NOM Certified (#057) All devices are UL Listed and CSA certified.
• Backed by a Lifetime Warranty

MATERIAL CHARACTERISTICS
Environmental: Flammability per UL94 or CSA
C22/06 Requirements
Operating Temperature: -40°C to 60°C Ø 1.53 (38.9 mm) 1.30 (32.9 mm)
2.76 (70.1 mm)
2.11 (53.57 mm)
Ø 1.53 (38.9 mm)
Ø 1.39 (35.3 mm)
2.11 (53.6 mm)

SUGGESTED PANEL
OPENING FOR 15A,
20A STRAIGHT BLADE
AND 15A LOCKING
FLANGED INLETS
AND OUTLETS
ANGLE LOCKING PLUG LOCKING CONNECTOR
Cat. No. 4570-CA Cat. No. 4579-C
Ø 1.75 (44.45mm) max.
Ø1.72 (43.66mm) min.

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World
J3
Locking Devices

15 AMP Locking Devices


15 AMP 3Ø 250V 3-Pole 3-Wire Non-Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle ★ 4870** Y

Single Flush Receptacle, 4870-SS L11-15R X


Z

w/Short Strap★
Locking Plug, Black Nylon Body★ 4880-C .245–.700 10–18 Y

L11-15P X

Locking Connector, 4889-C .245–.700 10–18 Z

Black Nylon Body★

20 AMP Locking Devices 2310

20 AMP 125V 2-Pole 3-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
V-0-MAX™ Single Flush Receptacle 2310†
V-0-MAX™ Single Flush Receptacle, 2310-IG†
Isolated Ground
Locking Plug, Black Nylon Body 2311 .385–.780 10–18
Locking Plug, all Black 2311-B .385–.780 10–18 W

for Stage and Studio L5-20R G

Locking Plug, Yellow Nylon Body 2311-CY .385–.780 10–18


Locking Connector, Black Nylon Body 2313 .385–.780 10–18 L5-20P
W

Locking Connector, all Black 2313-B .385–.780 10–18


for Stage and Studio
2313
Locking Connector, Yellow Nylon Body 2313-CY .385–.780 10–18
Locking Flanged Inlet 2315
Locking Flanged Outlet 2316
SPECIFICATIONS & FEATURES
**Uses stainless steel wallplate, Cat. No. 84004-40. †Uses stainless steel wallplate, Cat. No. 84020-40. • V-0-MAX™ Locking Receptacles carry a UL
For additional wallplate selections, please see Section G. 94 V-0 Flammability Rating, the best rating of
For Corrosion Resistant Locking Devices, please check pages K2–K5 any material used in Industrial Locking Flush
Receptacle available today
Weather-Resistant Boots for 20A Locking Plugs and Connectors are listed on page J20
• Locking Plugs and Connectors feature
All devices are UL Listed. Also CSA certified except where indicated by★ heavy-duty construction for top performance
in the environmental extremes of grueling
industrial settings
1.06 (26.8 mm) 1.69 (42.8 mm) • Flanged Inlets and Outlets are built to endure
hard use with rugged nylon flanges that
assure a smooth, flush fit and outstanding
resistance to cracking and breaking

TESTING & CODE COMPLIANCE


2.38 (60.3 mm)

3.28 (83.3 mm)


3.63 (92.1 mm)
2.67 (67.8mm)

(39.7 mm)

• All receptacles, plugs, connectors, inlets and


Ø 1.56

outlets are designed to meet NEMA WD-6,


and ANSI C-73, and to meet/exceed UL 498
standards
• UL Fed Spec. Listed WC-596 (File #E-13399
— Cat. Nos. 4870, 2310, 2316; File
#E-13393 — Cat. Nos. 4880-C, 4889-C,
2311, 2313, 2315)
• CSA Certified (File #LR-406)
1.31 (33.2 mm) 0.75 (19.1 mm) • NOM Certified (#057)
• Backed by a Lifetime Warranty
SINGLE LOCKING RECEPTACLE
Cat. No. 2310 MATERIAL CHARACTERISTICS
Environmental: Flammability per UL94 or CSA
C22/06 Requirements
2.47 (63.0 mm) Operating Temperature: -40°C to 60°C

Ø 2.13 ± 0.01
Ø 2.08 (53.0 mm)

(54.0 mm ± 0.3)
Ø 1.84 (47.0 mm)

PANEL OPENING
FOR ALL 20A / 30A
120

°
120

3 WIRE INLETS &


°

OUTLETS

TAP FOR #8-32 UNC SCREW


(3) PLACES
LOCKING PLUG Ø 2.50 ± 0.01
Cat. No. 2311 (63.5 mm ± 0.3)

For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World
J4
Locking Devices

20 AMP Locking Devices


20 AMP 250V 2-Pole 3-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
V-0-MAX™ Single Flush Receptacle 2320†
V-0-MAX™ Single Flush Receptacle, 2320-IG†
Isolated Ground X

Locking Plug, Black Nylon Body 2321 .385–.780 10–18 L6-20R G

Locking Plug, Yellow Nylon Body 2321-CY .385–.780 10–18


Locking Connector, Black Nylon Body 2323 .385–.780 10–18 L6-20P
X

Locking Connector, Yellow Nylon Body 2323-CY .385–.780 10–18 Y

2340
Locking Flanged Inlet 2325
Locking Flanged Outlet 2326

20 AMP 277V 2-Pole 3-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
V-0-MAX™ Single Flush Receptacle 2330†
V-0-MAX™ Single Flush Receptacle, 2330-IG† G
W

L7-20R
Isolated Ground
Locking Plug, Black Nylon Body 2331 .385–.780 10–18
W
Locking Connector, Black Nylon Body 2333 .385–.780 10–18 L7-20P
G

Locking Flanged Inlet 2335


Locking Flanged Outlet 2336
2341
20 AMP 347V 2-Pole 3-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
SPECIFICATIONS & FEATURES V-0-MAX™ Single Flush Receptacle* 3720†
• V-0-MAX™ Locking Receptacles carry a UL
94 V-0 Flammability Rating, the best rating of Locking Plug, Black Nylon Body* 3721 .385–.780 10–18 L24-20R
any material used in Industrial Locking Flush
Receptacle available today Locking Connector, Black 3723 .385–.780 10–18
• Locking Plugs and Connectors feature Nylon Body*
heavy-duty construction for top performance Locking Flanged Inlet* 3755 L24-20P
in the environmental extremes of grueling
industrial settings Locking Flanged Outlet* 3756
• Flanged Inlets and Outlets are built to endure
hard use with rugged nylon flanges that
assure a smooth, flush fit and outstanding 20 AMP 480V 2-Pole 3-Wire Grounding
resistance to cracking and breaking
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
TESTING & CODE COMPLIANCE (inches) (stranded) CONFIG.
• All receptacles, plugs, connectors, inlets and Single Flush Receptacle 2340†
outlets are designed to meet NEMA WD-6,
and ANSI C-73, and to meet/exceed UL 498 Single Flush Receptacle, 2340-IG† X

standards Isolated Ground L8-20R G

• UL Fed Spec. Listed WC-596 (File #E-13399 Y

— Cat. Nos. 2320, 2326, 2330, 2336, 3720, Locking Plug, Black Nylon Body 2341 .385–.780 10–18
3756, 2335, 2340, 2346; File #E-13393 —
Locking Connector, Black Nylon Body 2343 .385–.780 10–18
X

Cat. Nos. 2321, 2323, 2325, 2331, 2333, L8-20P G

2335, 3721, 3723, 3755, 2341,2343, 2345) Locking Flanged Inlet 2345 Y

• CSA Certified (File #LR-406)


• NOM Certified (#057) Locking Flanged Outlet 2346
• Backed by a Lifetime Warranty †Uses stainless steel wallplate, Cat. No. 84020-40. For additional wallplate selections, please see Section G.
MATERIAL CHARACTERISTICS For Corrosion Resistant Locking Devices, please check pages K2–K5
Environmental: Flammability per UL94 or CSA Weather-Resistant Boots for 20A Locking Plugs and Connectors are listed on page J20
C22/06 Requirements All devices are UL Listed except where indicated by*. Also CSA certified.
Operating Temperature: -40°C to 60°C 1.13 (28.6 mm) 0.75 (19.1 mm)

Ø 2.13 ± 0.01
(54.0 mm ± 0.3)
2.47 (63.0 mm)
2.38 (60.3 mm)

3.28 (83.3 mm)


3.65 (92.6 mm)
2.39 (60.7mm)

(39.7 mm)
Ø 1.56

Ø 2.08 (53.0 mm)

Ø 1.84 (47.0 mm)

PANEL OPENING
FOR ALL 20A / 30A
120

°
120

3 WIRE INLETS &


°

OUTLETS

TAP FOR #8-32 UNC SCREW 1.43 (36.2 mm) 1.70 (43.3 mm)
(3) PLACES
Ø 2.50 ± 0.01 SINGLE RECEPTACLE, ISOLATED GROUND LOCKING PLUG
(63.5 mm ± 0.3)
Cat. No. 2340-IG Cat. No. 2341

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World
J5
Locking Devices

20 AMP Locking Devices


20 AMP 600V 2-Pole 3-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle 2350†
Single Flush Receptacle, 2350-IG† X

Isolated Ground L9-20R G

Locking Plug, Black Nylon Body 2351 .385–.780 10–18


Locking Connector, Black Nylon Body 2353 .385–.780 10–18
X

L9-20P G

Locking Flanged Inlet 2355 Y

Locking Flanged Outlet 2356


2371

20 AMP 125/250V 3-Pole 3-Wire Non-Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 2360† X

Locking Plug, Black Nylon Body★ 2361 .385–.780 10–18 L10-20R W

Locking Connector, Black Nylon Body★ 2363 .385–.780 10–18


X

Locking Flanged Inlet★ 2365 L10-20P W

Locking Flanged Outlet★ 2366

20 AMP 3Ø 250V 3-Pole 3-Wire Non-Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 2370† Y 2376
Locking Plug, Black Nylon Body★ 2371 .385–.780 10–18 L11-20R X

Locking Connector, Black Nylon Body★ 2373 .385–.780 10–18


Y

Locking Flanged Inlet★ 2375 L11-20P X SPECIFICATIONS & FEATURES


Locking Flanged Outlet★ • Locking Receptacles feature a complete
Z
2376
range of ratings and NEMA configurations,
including isolated ground and non-grounding
20 AMP 3Ø 480V 3-Pole 3-Wire Non-Grounding • Locking Plugs and Connectors feature
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA heavy-duty construction for top performance
in the environmental extremes of grueling
(inches) (stranded) CONFIG. industrial settings
Single Flush Receptacle★ 2380† Y • Flanged Inlets and Outlets are built to endure
hard use with rugged nylon flanges that
Locking Plug, Black Nylon Body★ L12-20R X
2381 .385–.780 10–18 Z assure a smooth, flush fit and outstanding
Locking Connector, Black Nylon Body★ 2383 .385–.780 10–18 resistance to cracking and breaking
Y

Locking Flanged Inlet★ 2385 L12-20P X


TESTING & CODE COMPLIANCE
Locking Flanged Outlet★
Z

2386 • All receptacles, plugs, connectors, inlets and


outlets are designed to meet NEMA WD-6,
†Uses stainless steel wallplate, Cat. No. 84020-40. For additional wallplate selections, please see Section G. and ANSI C-73, and to meet/exceed UL 498
For Corrosion Resistant Locking Devices, please check pages K2–K5 standards
Weather-Resistant Boots for 20A Locking Plugs and Connectors are listed on page J20 • UL Fed Spec. Listed WC-596 (File #E-13399
— Cat. Nos. 2350, 2356, 2360, 2366, 2370,
All devices are UL Listed. Also CSA certified except where indicated by★ 2376, 2380, 2386; File #E-13393 — Cat. Nos.
2351, 2353, 2355, 2361, 2363, 2365, 2371,
2373, 2375, 2381, 2383, 2385)
• CSA Certified (File #LR-406)
• NOM Certified (#057)
120° 120° 2.29 (58.3 mm) • Backed by a Lifetime Warranty
2.06 (52.4 mm) 2.11 (53.6 mm)
MATERIAL CHARACTERISTICS
Environmental: Flammability per UL94 or CSA
C22/06 Requirements
Ø 2.05 (52.0 mm)

1.84 (46.8 mm)

Ø 0.20 Ø 0.20
(5.2 mm) (5.2 mm) Operating Temperature: -40°C to 60°C

Ø 2.13 ± 0.01
(54.0 mm ± 0.3)

Ø 2.50 (63.5 mm) Ø 2.50 (63.5 mm) PANEL OPENING


Ø 2.87 (72.9 mm) Ø 2.87 (72.9 mm) FOR ALL 20A / 30A
120

°
120

3 WIRE INLETS &


°

LOCKING FLANGED INLET LOCKING FLANGED OUTLET OUTLETS


Cat. No. 2375 Cat. No. 2376
TAP FOR #8-32 UNC SCREW
(3) PLACES
Ø 2.50 ± 0.01
(63.5 mm ± 0.3)

For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World
J6
Locking Devices

20 AMP Locking Devices


20 AMP 125/250V 3-Pole 4-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
V-0-MAX™ Single Flush Receptacle 2410†
V-0-MAX™ Single Flush Receptacle, 2410-IG† X

Isolated Ground L14-20R G


W

Y
Locking Plug, Black Nylon Body 2411 .595–.895 10–18 X

Locking Connector, Black Nylon Body 2413 .595–.895 10–18 L14-20P W G

Locking Flanged Inlet 2415 Y

Locking Flanged Outlet 2416


2411

20 AMP 3Ø 250V 3-Pole 4-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
V-0-MAX™ Single Flush Receptacle 2420†
X
V-0-MAX™ Single Flush Receptacle, 2420-IG†
Isolated Ground L15-20R G Y

Locking Plug, Black Nylon Body 2421 .595–.895 10–18


X

Locking Connector, Black Nylon Body 2423 .595–.895 10–18 L15-20P Y G

Locking Flanged Inlet 2425 Z

Locking Flanged Outlet 2426

20 AMP 3Ø 480V 3-Pole 4-Wire Grounding


2413 DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
V-0-MAX™ Single Flush Receptacle 2430†
V-0-MAX™ Single Flush Receptacle, 2430-IG† X

SPECIFICATIONS & FEATURES Isolated Ground L16-20R G Y

• V-0-MAX™ Locking Receptacles carry a UL Z

94 V-0 Flammability Rating, the best rating of Locking Plug, Black Nylon Body 2431 .595–.895 10–18 X
any material used in Industrial Locking Flush Locking Connector, Black Nylon Body 2433 .595–.895 10–18
Receptacle available today L16-20P Y G

• Locking Plugs and Connectors feature Locking Flanged Inlet 2435 Z

heavy-duty construction for top performance


in the environmental extremes of grueling Locking Flanged Outlet 2436
industrial settings
• Flanged Inlets and Outlets are built to endure
hard use with rugged nylon flanges that 20 AMP 3ØY 120/208V 4-Pole 4-Wire Non-Grounding
assure a smooth, flush fit and outstanding
resistance to cracking and breaking DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
TESTING & CODE COMPLIANCE Single Flush Receptacle★ 2440† X

• All receptacles, plugs, connectors, inlets and


Locking Plug, Black Nylon Body★
W Y
L18-20R
outlets are designed to meet NEMA WD-6, 2441 .595–.895 10–18
Z
and ANSI C-73, and to meet/exceed UL 498 Locking Connector, Black Nylon Body★ 2443 .595–.895 10–18
standards X

• UL Fed Spec. Listed WC-596 (File #E-13399 Locking Flanged Inlet★ 2445 L18-20P Y
W

— Cat. Nos. 2410, 2416, 2420, 2426, 2430,


2436, 2440, 2446; File #E-13393 — Cat. Locking Flanged Outlet★ 2446 Z

Nos. 2411, 2413, 2415, 2421, 2423, 2425,


2431, 2433, 2435, 2441, 2443, 2445) †Uses stainless steel wallplate, Cat. No. 84020-40. For additional wallplate selections, please see Section G.
• CSA Certified (File #LR-406) For Corrosion Resistant Locking Devices, please check pages K2–K5
• NOM Certified (#057) Weather-Resistant Boots for 20A Locking Plugs and Connectors are listed on page J20
• Backed by a Lifetime Warranty All devices are UL Listed. Also CSA certified except where indicated by★
MATERIAL CHARACTERISTICS
Environmental: Flammability per UL94 or CSA
C22/06 Requirements 2.70 (69.0 mm)
Operating Temperature: -40°C to 60°C 3.78 (96 mm)
Ø 1.97 (50.0 mm)

Ø 2.22 (56.0 mm)


Ø 2.22 (56.0 mm)

Ø 1.97 (50.0 mm)

Ø 2.28 (57.94mm)
Ø 2.25 (57.15mm)

PANEL OPENING
FOR ALL
20A / 30A
4 AND 5 WIRE
INLETS &
120

°
120

LOCKING PLUG LOCKING CONNECTOR


OUTLETS
°

Cat. No. 2411 Cat. No. 2413


TAP FOR #8-32 UNC SCREW
(3) PLACES
Ø 2.687 ± 0.01
(68.25mm ± 0.3)

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World
J7
Locking Devices

20 AMP Locking Devices


20 AMP 3ØY 277/480V 4-Pole 4-Wire Non-Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 2450† X

Locking Plug, Black Nylon Body★


Y
2451 .595–.895 10–18 L19-20R W

Locking Connector, Black Nylon Body★ 2453 .595–.895 10–18 X

Locking Flanged Inlet★ 2455 L19-20P Y W

Locking Flanged Outlet★ 2456 Z

20 AMP 3ØY 347/600V 4-Pole 4-Wire Non-Grounding


2523
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 2460† X

Locking Plug, Black Nylon Body★ L20-20R W Y

2461 .595–.895 10–18


Z

Locking Connector, Black Nylon Body★ 2463 .595–.895 10–18 X

Locking Flanged Inlet★ 2465 L20-20P Y W

Locking Flanged Outlet★ 2466 Z

20 AMP 3ØY 120/208V 4-Pole 5-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle 2510†
Single Flush Receptacle, 2510-IG† X

Y
Isolated Ground L21-20R W
G

Z
2525
Locking Plug, Black Nylon Body 2511 .595–.895 10–18 X

Locking Connector, Black Nylon Body 2513 .595–.895 10–18 L21-20P Y


G
W

Locking Flanged Inlet 2515 Z

SPECIFICATIONS & FEATURES


Locking Flanged Outlet 2516 • Locking Receptacles feature a complete
range of ratings and NEMA configurations,
including isolated ground and non-grounding
20 AMP 3ØY 277/480V 4-Pole 5-Wire Grounding • Locking Plugs and Connectors feature
heavy-duty construction for top performance
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA in the environmental extremes of grueling
(inches) (stranded) CONFIG. industrial settings
Single Flush Receptacle 2520† • Flanged Inlets and Outlets are built to endure
hard use with rugged nylon flanges that
Single Flush Receptacle, 2520-IG† X

assure a smooth, flush fit and outstanding


Isolated Ground L22-20R W
G
Y
resistance to cracking and breaking
Z
Locking Plug, Black Nylon Body 2521 .595–.895 10–18
X
TESTING & CODE COMPLIANCE
Locking Connector, Black Nylon Body 2523 .595–.895 10–18 L22-20P Y W
• All receptacles, plugs, connectors, inlets and
G

Locking Flanged Inlet 2525 Z


outlets are designed to meet NEMA WD-6,
and ANSI C-73, and to meet/exceed UL 498
Locking Flanged Outlet 2526 standards
• UL Fed. Spec. Listed WC-596 (File #13399 –
†Uses stainless steel wallplate, Cat. No. 84020-40. For additional wallplate selections, please see Section G. Cat. Nos. 2450, 2456, 2460, 2466, 2510,
For Corrosion Resistant Locking Devices, please check pages K2–K5 2516, 2520, 2526; File #13393 – Cat. Nos.
2451, 2453, 2455, 2461, 2463, 2465, 2511,
Weather-Resistant Boots for 20A Locking Plugs and Connectors are listed on page J20 2513, 2515, 2521, 2523, 2525)
All devices are UL Listed. Also CSA certified except where indicated by★ • CSA Certified (File #LR-406)
• NOM Certified (#057)
• Backed by a Lifetime Warranty

MATERIAL CHARACTERISTICS
Environmental: Flammability per UL94 or CSA
3.78 (96 mm) C22/06 Requirements
Operating Temperature: -40°C to 60°C
Ø 2.22 (56.0 mm)

Ø 2.28 (57.94mm)
Ø 1.97 (50.0 mm)

Ø 2.25 (57.15mm)

PANEL OPENING
FOR ALL
20A / 30A
4 AND 5 WIRE
INLETS &
120

°
120

OUTLETS
°

LOCKING CONNECTOR
TAP FOR #8-32 UNC SCREW
Cat. No. 2523 (3) PLACES
Ø 2.687 ± 0.01
(68.25mm ± 0.3)

For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World
J8
Locking Devices

20 AMP Locking Devices


20 AMP 3ØY 347/600V 4-Pole 5-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle 2530†
X

Single Flush Receptacle, 2530-IG†


L23-20R Y

Isolated Ground W
G

Locking Plug, Black Nylon Body 2531 .595–.895 10–18 X

Locking Connector, Black Nylon Body 2533 .595–.895 10–18 L23-20P Y


G
W

Locking Flanged Inlet 2545 Z

Locking Flanged Outlet 2546


2610

30 AMP Locking Devices


30 AMP 125V 2-Pole 3-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
V-0-MAX™ Single Flush Receptacle 2610†
V-0-MAX™ Single Flush Receptaclee, 2610-IG†
Isolated Ground
Locking Plug, Black Nylon Body 2611 .385–.860 10–18
Locking Plug, All Black for W

Stage and Studio 2611-B .385–.860 10–18 L5-30R G

Locking Plug, Yellow Nylon Body 2611-CY .385–.860 10–18 W

Locking Connector, Black Nylon Body 2613 .385–.860 10–18 L5-30P G

2611 Locking Connector, All Black for 2613-B .385–.860 10–18


Stage and Studio
Locking Connector, Yellow Nylon Body 2613-CY .385–.860 10–18
Locking Flanged Inlet 2615
SPECIFICATIONS & FEATURES
Locking Flanged Outlet 2616
• V-0-MAX™ Locking Receptacles carry a UL
94 V-0 Flammability Rating, the best rating of
any material used in Industrial Locking Flush 30 AMP 250V 2-Pole 3-Wire Grounding
Receptacle available today
• Locking Plugs and Connectors feature DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
heavy-duty construction for top performance (inches) (stranded) CONFIG.
in the environmental extremes of grueling
industrial settings V-0-MAX™ Single Flush Receptacle 2620†
• Flanged Inlets and Outlets are built to endure V-0-MAX™ Single Flush Receptacle,
hard use with rugged nylon flanges that Isolated Ground 2620-IG†
assure a smooth, flush fit and outstanding
resistance to cracking and breaking Locking Plug, Black Nylon Body 2621 .385–.860 10–18
Locking Plug, All Black for 2621-B .385–.860 10–18 X

TESTING & CODE COMPLIANCE Stage and Studio L6-30R G

Y
• All receptacles, plugs, connectors, inlets and
outlets are designed to meet NEMA WD-6, Locking Plug, Yellow Nylon Body 2621-CY .385–.860 10–18 X

and ANSI C-73, and to meet/exceed UL 498 Locking Connector, Black Nylon Body C2623 .385–.860 10–18
standards L6-30P G

Locking Connector, All Black for C2623-B .385–.860 10–18


Y
• UL Fed Spec. Listed WC-596 (File #E-13399
— Cat. Nos. 2530, 2546, 2610, 2616, 2620, Stage and Studio
2626F; File #E-13393 — Cat. Nos. 2531,
2533, 2545, 2611, 2613, 2615, 2621, 2623, Locking Connector, Yellow Nylon Body C2623-CY .385–.860 10–18
2625F)
• CSA Certified (File #LR-406) Locking Flanged Inlet 2625F
• NOM Certified (#057) Locking Flanged Outlet 2626F
• Backed by a Lifetime Warranty
†Uses stainless steel wallplate, Cat. No. 84020-40. For additional wallplate selections, please see Section G.
MATERIAL CHARACTERISTICS For Corrosion Resistant Locking Devices, please check pages K2–K5
Environmental: Flammability per UL94 or CSA Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page J20
C22/06 Requirements All devices are UL Listed and CSA certified.
Operating Temperature: -40°C to 60°C 120°
1.06 (26.8 mm) 1.69 (42.8 mm) 2.06 (52.4 mm)
Ø 2.13 ± 0.01
(54.0 mm ± 0.3)
Ø 2.05 (52.0 mm)

Ø 0.20
3.28 (83.3 mm)
2.38 (60.3 mm)
2.67 (67.8 mm)

3.63 (92.1 mm)

(5.2 mm)
(39.7 mm)

PANEL OPENING
Ø 1.56

FOR ALL 20A / 30A


120

°
120

3 WIRE INLETS &


°

OUTLETS

TAP FOR #8-32 UNC SCREW


Ø 2.50 (63.5 mm)
(3) PLACES 1.31 (33.2 mm) 0.75 (19.1 mm) Ø 2.87 (72.9 mm)
Ø 2.50 ± 0.01
(63.5 mm ± 0.3) SINGLE LOCKING RECEPTACLE LOCKING FLANGED INLET
Cat. No. 2610 Cat. No. 2615

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World
J9
Locking Devices

30 AMP Locking Devices


30 AMP 277V 2-Pole 3-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle 2630†
Single Flush Receptacle, 2630-IG† W

Isolated Ground L7-30R G

Locking Plug, Black Nylon Body 2631 .385–.860 10–18


W

Locking Connector, Black Nylon Body 2633 .385–.860 10–18 L7-30P G

Locking Flanged Inlet 2635


Locking Flanged Outlet 2636
2661
30 AMP 480V 2-Pole 3-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle 2640†
Single Flush Receptacle, 2640-IG† X

Isolated Ground L8-30R G

Locking Plug, Black Nylon Body 2641 .385–.860 10–18


X

Locking Connector, Black Nylon Body 2643 .385–.860 10–18 L8-30P G

Locking Flanged Inlet 2645 Y

Locking Flanged Outlet 2646

30 AMP 600V 2-Pole 3-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG. 2663
Single Flush Receptacle 2650†
Single Flush Receptacle, 2650-IG† X

Isolated Ground L9-30R G

Y SPECIFICATIONS & FEATURES


Locking Plug, Black Nylon Body C2651 .385–.860 10–18 • Locking Receptacles feature a complete
X

Locking Connector, Black Nylon Body C2653 .385–.860 10–18 range of ratings and NEMA configurations,
L9-30P
Y
G
including isolated ground and non-grounding
Locking Flanged Inlet 2655 • Locking Plugs and Connectors feature
Locking Flanged Outlet 2656 heavy-duty construction for top performance
in the environmental extremes of grueling
industrial settings
30 AMP 125/250V 3-Pole 3-Wire Non-Grounding • Flanged Inlets and Outlets are built to endure
hard use with rugged nylon flanges that
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA assure a smooth, flush fit and outstanding
(inches) (stranded) CONFIG. resistance to cracking and breaking
Single Flush Receptacle★ 2660-A† X

TESTING & CODE COMPLIANCE


Locking Plug, Black Nylon Body★ 2661 .385–.860 10–18 L10-30R W

Y
• All receptacles, plugs, connectors, inlets and
Locking Connector, Black Nylon Body★ 2663 .385–.860 10–18 outlets are designed to meet NEMA WD-6,
X and ANSI C-73, and to meet/exceed UL 498
Locking Flanged Inlet★ 2665 L10-30P W
standards
• UL Fed. Spec. Listed WC-596 (File #E-
Locking Flanged Outlet★
Y

2666 13399 – Cat. Nos., 2630, 2636, 2640, 2646,


2650, 2656, 2660, 2666; File #E-13393 –
†Uses stainless steel wallplate, Cat. No. 84020-40. For additional wallplate selections, please see Section G. Cat. Nos. 2631, 2633, 2635, 2641, 2643,
For Corrosion Resistant Locking Devices, please check pages K2–K5 2645 C2651, C2653, 2655, 2661, 2663,
2665)
Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page J20 • CSA Certified (File #LR-406)
All devices are UL Listed. Also CSA certified except where indicated by★ • NOM Certified (#057)
• Backed by a Lifetime Warranty

MATERIAL CHARACTERISTICS
Environmental: Flammability per UL94 or CSA
C22/06 Requirements
Operating Temperature: -40°C to 60°C
Ø 1.84 (46.8 mm)

Ø 1.84 (46.8 mm)

Ø 2.13 ± 0.01
(54.0 mm ± 0.3)

PANEL OPENING
FOR ALL 20A / 30A
Ø 2.08 (52.8 mm) 2.48 (62.9 mm) 2.08 (52.8 mm) 3.53 (89.7 mm)
120

°
120

3 WIRE INLETS &


°

OUTLETS
LOCKING PLUG LOCKING CONNECTOR
Cat. No. 2661 Cat. No. 2663 TAP FOR #8-32 UNC SCREW
(3) PLACES
Ø 2.50 ± 0.01
(63.5 mm ± 0.3)

For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World
J 10
Locking Devices

30 AMP Locking Devices


30 AMP 3Ø 250V 3-Pole 3-Wire Non-Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 2670† Y

Locking Plug, Black Nylon Body★ 2671 .385–.860 10–18 L11-30R X


Z

Locking Connector, Black Nylon Body★ 2673 .385–.860 10–18 Y

Locking Flanged Inlet★ 2675 L11-30P X


Z

Locking Flanged Outlet★ 2676

2710
30 AMP 3Ø 480V 3-Pole 3-Wire Non-Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 2680† Y

Locking Plug, Black Nylon Body★ L12-30R X


2681 .385–.860 10–18
Z

Locking Connector, Black Nylon Body★ 2683 .385–.860 10–18 Y

Locking Flanged Inlet★ 2685 L12-30P X

Locking Flanged Outlet★


Z
2686

30 AMP 3Ø 600V 3-Pole 3-Wire Non-Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 2690† Y

Locking Plug, Black Nylon Body★ L13-30R X


2691 .385–.860 10–18 Z

2716 Locking Connector, Black Nylon Body★ 2693 .385–.860 10–18 Y

Locking Flanged Inlet★ 2695 L13-30P X

Locking Flanged Outlet★ 2696


SPECIFICATIONS & FEATURES
• V-0-MAX™ Locking Receptacles carry a UL 30 AMP 125/250V 3-Pole 4-Wire Grounding
94 V-0 Flammability Rating, the best rating of
any material used in Industrial Locking Flush DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
Receptacle available today (inches) (stranded) CONFIG.
• Locking Plugs and Connectors feature V-0-MAX™ Single Flush Receptacle 2710†
heavy-duty construction for top performance
in the environmental extremes of grueling V-0-MAX™ Single Flush Receptacle, 2710-IG†
industrial settings Isolated Ground X

• Flanged Inlets and Outlets are built to endure Locking Plug, Black Nylon Body 2711 .595–1.150 10–18 L14-30R G
W

hard use with rugged nylon flanges that Y

assure a smooth, flush fit and outstanding Locking Plug, Yellow Nylon Body 2711-CY .595–1.150 10–18
resistance to cracking and breaking X

Locking Connector, Black Nylon Body 2713 .595–1.150 10–18 L14-30P W G

TESTING & CODE COMPLIANCE Locking Connector, Yellow Nylon Body 2713-CY .595–1.150 10–18 Y

• All receptacles, plugs, connectors, inlets and Locking Flanged Inlet 2715
outlets are designed to meet NEMA WD-6,
and ANSI C-73, and to meet/exceed UL 498 Locking Flanged Outlet 2716
standards
†Uses stainless steel wallplate, Cat. No. 84020-40. For additional wallplate selections, please see Section G.
• UL Fed. Spec. Listed WC-596 (File #13399 –
Cat. Nos. 2670, 2676, 2680, 2686, 2690, For Corrosion Resistant Locking Devices, please check pages K2–K5
2696 2710, 2716; File #E-13393 – Cat. Nos., Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page J20
2671, 2673, 2675, 2681, 2683, 2685, 2691, All devices are UL Listed. Also CSA certified except where indicated by★
2693, 2695, 2711, 2713, 2715)
• CSA Certified (File #LR-406)
• NOM Certified (File #057)
• Backed by a Lifetime Warranty

MATERIAL CHARACTERISTICS 1.06 (26.8 mm) 1.69 (42.8 mm) 12
Environmental: Flammability per UL94 or CSA
C22/06 Requirements
Ø 2.22 (56.3 mm)

Operating Temperature: -40°C to 60°C


2.67 (67.8 mm)

2.38 (60.3 mm)

3.28 (83.3 mm)


3.63 (92.1 mm)
(39.7 mm)

Ø 2.28 (57.94mm)
Ø 1.56

Ø 2.25 (57.15mm) Ø 0.20 (5.2 mm)


PANEL OPENING
FOR ALL
20A / 30A 2.37 (60.3 mm)
4 AND 5 WIRE Ø 2.69 (68.2 mm)
INLETS & Ø 3.03 (77.0 mm)
120

1.31 (33.2 mm)


°

0.75 (19.1 mm)


120

OUTLETS
°

SINGLE RECEPTACLE LOCKING FLANGED OUTLET


TAP FOR #8-32 UNC SCREW Cat. No. 2710 Cat. No. 2716
(3) PLACES
Ø 2.687 ± 0.01
(68.25mm ± 0.3)

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World
J 11
Locking Devices

30 AMP Locking Devices


30 AMP 3Ø 250V 3-Pole 4-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
V-0-MAX™ Single Flush Receptacle 2720†
X

V-0-MAX™ Single Flush Receptacle, 2720-IG†


L15-30R G
Isolated Ground Y

Locking Plug, Black Nylon Body 2721 .595–1.150 10–18 X

Locking Connector, Black Nylon Body 2723 .595–1.150 10–18 L15-30P Y G

Locking Flanged Inlet 2725 Z

Locking Flanged Outlet 2726


2730
30 AMP 3Ø 480V 3-Pole 4-Wire Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
V-0-MAX™ Single Flush Receptacle 2730†
X

V-0-MAX™ Single Flush Receptacle, 2730-IG†


L16-30R G
Isolated Ground Y

Locking Plug, Black Nylon Body 2731 .595–1.150 10–18 X

Locking Connector, Black Nylon Body 2733 .595–1.150 10–18 L16-30P Y G

Locking Flanged Inlet 2735 Z

Locking Flanged Outlet★ 2736

30 AMP 3Ø 600V 3-Pole 4-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
2731
Single Flush Receptacle★ 2740†
X
Single Flush Receptacle, 2740-IG†
Isolated Ground★ L17-30R G Y

Locking Plug, Black Nylon Body 2741 .595–1.150 10–18 SPECIFICATIONS & FEATURES
X

Locking Connector, Black Nylon Body 2743 .595–1.150 10–18 • V-0-MAX™ Locking Receptacles carry a UL
L17-30P Y G
94 V-0 Flammability Rating, the best rating of
Locking Flanged Inlet 2745 Z any material used in Industrial Locking Flush
Receptacle available today
Locking Flanged Outlet 2746
• Locking Plugs and Connectors feature
heavy-duty construction for top performance
30 AMP 3ØY 120/208V 4-Pole 4-Wire Non-Grounding in the environmental extremes of grueling
industrial settings
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG. • Flanged Inlets and Outlets are built to endure
hard use with rugged nylon flanges that
Single Flush Receptacle★ 2750† X
assure a smooth, flush fit and outstanding
resistance to cracking and breaking
Locking Plug, Black Nylon Body★ L18-30R Y
2751 .595–1.150 10–18 W

Locking Connector, Black Nylon Body★


Z

2753 .595–1.150 10–18 X TESTING & CODE COMPLIANCE


Locking Flanged Inlet★ 2755 L18-30P Y
W
• All receptacles, plugs, connectors, inlets and
outlets are designed to meet NEMA WD-6,
Locking Flanged Outlet★ 2756 Z
and ANSI C-73, and to meet/exceed UL 498
standards
†Uses stainless steel wallplate, Cat. No. 84020-40. For additional wallplate selections, please see Section G • UL Fed. Spec. Listed WC-596 (File #E-
For Corrosion Resistant Locking Devices, please check pages K2–K5 13399 – Cat. Nos., 2720, 2726, 2730, 2736,
2740, 2746, 2750, 2756; File # E-13393 –
Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page J20 Cat. Nos., 2721, 2723, 2725, 2731, 2733,
All devices are UL Listed. Also CSA certified except where indicated by★ 2735, 2741, 2743, 2745, 2751, 2753, 2755)
• CSA Certified (File #LR-406)
• NOM Certified (#057)
• Backed by a Lifetime Warranty

MATERIAL CHARACTERISTICS
2.70 (68.7 mm) 3.78 (96.0 mm) Environmental: Flammability per UL94 or CSA
C22/06 Requirements
Operating Temperature: -40°C to 60°C
Ø 2.22 (56.4 mm)
Ø 2.22 (56.4 mm)

Ø 1.97 (50.0 mm)


Ø 1.97 (50.0 mm)

Ø 2.28 (57.94mm)
Ø 2.25 (57.15mm)

PANEL OPENING
FOR ALL
20A / 30A
4 AND 5 WIRE
INLETS &
120

LOCKING PLUG
120

LOCKING CONNECTOR
OUTLETS
°

Cat. No. 2731 Cat. No. 2733

TAP FOR #8-32 UNC SCREW


(3) PLACES
Ø 2.687 ± 0.01
(68.25mm ± 0.3)

For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World
J 12
Locking Devices

30 AMP Locking Devices


30 AMP 3ØY 277/480V 4-Pole 4-Wire Non-Grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 2760† X

Locking Plug, Black Nylon Body★


W Y

2761 .595–1.150 10–18 L19-30R


Z

Locking Connector, Black Nylon Body★ 2763 .595–1.150 10–18 X

Locking Flanged Inlet★ 2765 L19-30P W Y

Locking Flanged Outlet★ 2766 Z

30 AMP 3ØY 347/600V 4-Pole 4-Wire Non-Grounding


2761 DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 2770† X

Locking Plug, Black Nylon Body★


W Y

2771 .595–1.150 10–18 L20-30R


Z

Locking Connector, Black Nylon Body★ 2773 .595–1.150 10–18 X

Locking Flanged Inlet★ 2775 L20-30P Y W

Locking Flanged Outlet★ 2776 Z

30 AMP 3ØY 120/208V 4-Pole 5-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle 2810†
X

Single Flush Receptacle, Isolated Ground 2810-IG† W


Y
L21-30R G

Locking Plug, Black Nylon Body 2811 .595–1.150 10–18 Z

2763
Locking Connector, Black Nylon Body 2813 .595–1.150 10–18 X

W Y

Locking Flanged Inlet 2815 L21-30P G

Locking Flanged Outlet 2816


SPECIFICATIONS & FEATURES
• Locking Receptacles feature a complete 30 AMP 3ØY 277/480V 4-Pole 5-Wire Grounding
range of ratings and NEMA configurations,
including isolated ground and non-grounding DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
• Locking Plugs and Connectors feature (inches) (stranded) CONFIG.
heavy-duty construction for top performance
in the environmental extremes of grueling Single Flush Receptacle 2820† X

industrial settings Single Flush Receptacle, Isolated Ground 2820-IG† W Y


L22-30R G
• Flanged Inlets and Outlets are built to endure
hard use with rugged nylon flanges that Locking Plug, Black Nylon Body 2821 .595–1.150 10–18 Z

assure a smooth, flush fit and outstanding Locking Connector, Black Nylon Body 2823 .595–1.150 10–18 X

resistance to cracking and breaking Y


Locking Flanged Inlet 2825 L22-30P G
W

TESTING & CODE COMPLIANCE Locking Flanged Outlet 2826


• All receptacles, plugs, connectors, inlets and
outlets are designed to meet NEMA WD-6,
and ANSI C-73, and to meet/exceed UL 498 30 AMP 3ØY 347/600V 4-Pole 5-Wire Grounding
standards
• UL Fed Spec. Listed WC-596 (File #E-13399
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
— Cat. Nos. 2760, 2766, 2770, 2776, 2810, (inches) (stranded) CONFIG.
2816, 2820, 2826, 2830, 2836; File Single Flush Receptacle 2830†
#E-13393 — Cat. Nos. 2761, 2763, 2765, X

2771, 2773, 2775, 2811, 2813, 2815, 2821, Single Flush Receptacle, Isolated Ground 2830-IG W
Y

2823, 2825, 2831, 2833, 2835) L23-30R G

• CSA Certified (File #LR-406) Locking Plug, Black Nylon Body 2831 .595–1.150 10–18 Z

• NOM Certified (#057) Locking Connector, Black Nylon Body 2833 .595–1.150 10–18 X

• Backed by a Lifetime Warranty L23-30P Y W


Locking Flanged Inlet 2835 G

MATERIAL CHARACTERISTICS Locking Flanged Outlet 2836


Environmental: Flammability per UL94 or CSA
C22/06 Requirements †Uses stainless steel wallplate, Cat. No. 84020-40. For additional wallplate selections, please see Section G.
Operating Temperature: -40°C to 60°C For Corrosion Resistant Locking Devices, please check pages K2–K5
Ø 2.28 (57.94mm)
Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page J20
Ø 2.25 (57.15mm) All devices are UL Listed. Also CSA certified except where indicated by★
PANEL OPENING
Ø 1.97 (50.0 mm)

Ø 1.97 (50.0 mm)

FOR ALL
20A / 30A
4 AND 5 WIRE
INLETS &
120

°
120

OUTLETS
°

TAP FOR #8-32 UNC SCREW Ø 2.22 (56.4 mm) 2.70 (68.7 mm) Ø 2.22 (56.4 mm) 3.78 (96 mm)
(3) PLACES
Ø 2.687 ± 0.01
(68.25mm ± 0.3) LOCKING PLUG LOCKING CONNECTOR
Cat. No. 2761 Cat. No. 2763
To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World
J13
Wetguard™™
Locking Devices

Wetguard™ Devices Engineered to IP66 & IP67 Watertight Standards


Wetguard™ Locking Plugs and Connectors
DESCRIPTION CAT. NO. PLUG CAT. NO. CONNECTOR
High-Visibility Yellow, 15A-125V 2-Pole, 3-Wire 24W47 W 25W47 W

L5-15P L5-15R
G G

High-Visibility Yellow, 15A-250V 2-Pole, 3-Wire 24W49 X 25W49 X

L6-15P G L6-15R G

Y Y

High-Visibility Yellow, 15A-277V 2-Pole, 3-Wire 24W34 W


G 25W34 G
W

L7-15P L7-15R

24W47
High-Visibility Yellow, 20A-125V 2-Pole, 3-Wire 26W47 W 27W47 W

G
L5-20P L5-20R G

Black, 20A-125V 2-Pole, 3-Wire 26W47-B W 27W47-B W

G
L5-20P L5-20R G

High-Visibility Yellow, 20A-250V 2-Pole, 3-Wire 26W48 X 27W48 X

L6-20P G
L6-20R G

Y Y

High-Visibility Yellow, 20A-277V 2-Pole, 3-Wire 26W49 W 27W49 G


W

G
L7-20P L7-20R

Locking Cord Sets 15 AMP 125V 2-Pole 3-Wire Grounding


DESCRIPTION LENGTH CAT. NO. CAT. NO. NEMA
14/3 SOOW 12/3 SOOW CONFIG.
Yellow Cord, Yellow Devices 25' WL515-43A WL515-23A W
25W47
L5-15R
G
Yellow Cord, Yellow Devices 50' WL515-43B WL515-23B
W
SPECIFICATIONS & FEATURES
Yellow Cord, Yellow Devices 100' WL515-43C WL515-23C L5-15P
G
Wetguard
• IEC IP66 and IP 67 Rated, in accor-
dance with IEC 529 as evaluated by
Repacement Closure Cap UL and CSA
• NEMA Type 4, 4X, 6 and 6P Ratings in
DESCRIPTION CAT. NO. accordance with UL 50 and CSA 94
• Outstanding resistance to wet and
Replacement Connector Closure Cap for 15A devices 50W50 damp environments, extreme tempera-
ture variations, acids, alkalis, grease,
Replacement Connector Closure Cap for 20A devices 50W52 oils and solvents
All locking devices are UL Listed and CSA certified. • Effective “tongue and groove” construc-
tion seals out water, moisture, dirt
4.20 (106.7 mm) when plugs are mated with connectors
• Innovative strain-relief grips cables
2.71 (68.8 mm)
securely, keeps out water and moisture
• Cord clamp range for 15A devices:
18/3–10/3 SO (.375"–.655"). For 20A
2.30 (58.3 mm)
Ø 1.28 (32.5 mm)

Ø 1.50 (38.1 mm)

(32.5 mm)dia.

devices: 18/3–10/5 SO, ST, SJ


(.375"–.870")
1.28

• Non-magnetic stainless steel fast-


threading assembly screws won’t
interfere with sensitive equipment
• Connector “hood” closure cap seals
device when not in use
WETGUARD™ 15A LOCKING PLUG
TESTING & CODE COMPLIANCE
• Meet NEMA WD 1 & 6, ANSI
requirements
WETGUARD™ 15A LOCKING CONNECTOR • UL Listed & meets Fed. Spec. require-
ments: (File #13393)
• CSA Certified (File #LR-406)
• NOM Certified (#057)
• Backed by a Lifetime Warranty

MATERIAL CHARACTERISTICS
2.50 (63.3 mm)
2.31 (58.7 mm)

Environmental: Flammability, Rated V2


Operating Temperature: -40°C to 60°C

3.58 (91.0 mm)


5.52 (140.2 mm)
WETGUARD™ 20A LOCKING PLUG
WETGUARD™ 20A LOCKING CONNECTOR

For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World
J14
Wetguard™™
Locking Devices

Wetguard™ Devices Engineered to IP66 & IP67 Watertight Standards


Wetguard™ Locking Plugs and Connectors
DESCRIPTION CAT. NO. PLUG CAT. NO. CONNECTOR
High-Visibility Yellow, 20A-125/250V 3-Pole, 4-Wire 26W74 X
27W74 X

L14-20P W G L14-20R G
W

Y Y

High-Visibility Yellow, 20A-3Ø 250V 3-Pole, 4-Wire 26W75 X


27W75 X

L15-20P Y G
L15-20R G Y

Z Z

High-Visibility Yellow, 20A-3Ø 480V 3-Pole, 4-Wire 26W76 X


27W76 X

L16-20P Y G L16-20R G Y

Z Z

26W74
High-Visibility Yellow, 20A-3ØY 120/208V 4-Pole, 5-Wire 26W81 X
27W81 X

Y Y
L21-20P G
W
L21-20R W
G

Z Z

Black, 20A-3ØY 120/208V 4-Pole, 5-Wire 26W81-B X


27W81-B X

Y Y
L21-20P G
W
L21-20R W
G

Z Z

High-Visibility Yellow, 20A-3ØY 277/480V 4-Pole, 5-Wire 26W82 X


27W82 X

Y
L22-20P G
W
L22-20R W
G
Y

Z Z

High-Visibility Yellow, 20A-3ØY 347/600V 4-Pole, 5-Wire 26W83 X


27W83 X

Y
L23-20P Y
G
W
L23-20R W
G

Z Z

Wetguard™ Non-NEMA, Non-Grounding Devices


(For Replacement Use Only)
27W74 DESCRIPTION CAT. NO. PLUG CAT. NO. CONNECTOR
High-Visibility Yellow, 20A-125/250V 3-Pole, 3-Wire★ 26W08 27W08
NON- NON-
NEMA NEMA
SPECIFICATIONS & FEATURES
Wetguard High-Visibility Yellow, 20A-3ØY 120/208V 4-Pole, 4-Wire★ 26W09 27W09
• IEC IP66 and IP 67 Rated, in accor- NON- NON-
NEMA NEMA
dance with IEC 529 as evaluated by
UL and CSA
• NEMA Type 4, 4X, 6 and 6P Ratings in
accordance with UL 50 and CSA 94 Repacement Closure Cap
• Outstanding resistance to wet and
damp environments, extreme tempera-
ture variations, acids, alkalis, grease, DESCRIPTION CAT. NO.
oils and solvents
• Effective “tongue and groove” construc- Replacement Connector Closure Cap for 20A devices 50W52
tion seals out water, moisture, dirt All locking devices are UL Listed. Also CSA certified except where indicated by★
when plugs are mated with connectors
• Innovative strain-relief grips cables
securely, keeps out water and moisture
• Cord clamp range for 20A devices:
18/3–10/5 SO, ST, SJ (.375"–.870")
• Non-magnetic stainless steel fast-
threading assembly screws won’t
interfere with sensitive equipment
• Connector “hood” closure cap seals
device when not in use

TESTING & CODE COMPLIANCE


• Meet NEMA WD 1 & 6, ANSI
requirements
2.31 (58.7 mm)

2.50 (63.3 mm)

• UL Listed & meets Fed. Spec. require-


ments: (File #13393)
• CSA Certified (File #LR-406)
• NOM Certified (#057)
• Backed by a Lifetime Warranty

MATERIAL CHARACTERISTICS
Environmental: Flammability, Rated V2
Operating Temperature: -40°C to 60°C 3.58 (91.0 mm)
5.52 (140.2 mm)
WETGUARD™ 20A LOCKING PLUG
WETGUARD™ 20A LOCKING CONNECTOR

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World
J15
Wetguard™™
Locking Devices

Wetguard™ Devices Engineered to IP66 & IP67 Watertight Standards


Wetguard™ Locking Plugs and Connectors
DESCRIPTION CAT. NO. PLUG CAT. NO. CONNECTOR
High-Visibility Yellow, 30A-125V 2-Pole, 3-Wire 28W47 W
29W47 W

L5-30P G L5-30R G

Black, 30A-125V 2-Pole, 3-Wire 28W47-B W


29W47-B W

L5-30P G L5-30R G

High-Visibility Yellow, 30A-250V 2-Pole, 3-Wire 28W48 X


29W48 X

L6-30P G
L6-30R G

Y
Y

28W74
High-Visibility Yellow, 30A-277V 2-Pole, 3-Wire 28W49 W 29W49 W

L7-30P G
L7-30R G

High-Visibility Yellow, 30A-125/250V 3-Pole, 4-Wire 28W74 X


29W74 X

W W
L14-30P G L14-30R G

Y Y

High-Visibility Yellow, 30A-3Ø 250V 3-Pole, 4-Wire 28W75 X


29W75 X

L15-30P Y G L15-30R G Y

Z Z

High-Visibility Yellow, 30A-3Ø 480V 3-Pole, 4-Wire 28W76 X


29W76 X

L16-30P Y G
L16-30R G Y

Z Z

High-Visibility Yellow, 30A-3Ø 600V 3-Pole, 4-Wire 28W77 X


29W77 X

L17-30P Y G L17-30R G Y

Z Z

High-Visibility Yellow, 30A-3ØY 120/208V 4-Pole, 5-Wire 28W81 X


29W81 X

W Y
W
Y 29W74
L21-30P G L21-30R G

Z Z

High-Visibility Yellow, 30A-3ØY 277/480V 4-Pole, 5-Wire 28W82 X


29W82 X

Y Y
L22-30P W W
G L22-30R G
SPECIFICATIONS & FEATURES
Z Z

Wetguard
High-Visibility Yellow, 30A-3ØY 347/600V 4-Pole, 5-Wire 28W83 X
29W83 X
• IEC IP66 and IP 67 Rated, in accor-
L23-30P Y
G
W
L23-30R
W
G
Y
dance with IEC 529 as evaluated by
Z Z
UL and CSA
• NEMA Type 4, 4X, 6 and 6P Ratings in
accordance with UL 50 and CSA 94
Wetguard™ Non-NEMA, Non-Grounding Devices • Outstanding resistance to wet and
(For Replacement Use Only) damp environments, extreme tempera-
ture variations, acids, alkalis, grease,
DESCRIPTION CAT. NO. PLUG CAT. NO. CONNECTOR oils and solvents
• Effective “tongue and groove” construc-
tion seals out water, moisture, dirt
High-Visibility Yellow, 30A-125/250V 3-Pole, 3-Wire★ 28W08 29W08 when plugs are mated with connectors
NON-NEMA NON-NEMA • Innovative strain-relief grips cables
securely, keeps out water and moisture
• Cord clamp range for 30A devices:
High-Visibility Yellow, 30A-3ØY 120/208V 4-Pole, 4-Wire★ 28W09 29W09 12/3–8/5 SO, ST, SJ (.625"–1.125")
NON-NEMA NON-NEMA • Non-magnetic stainless steel fast-
threading assembly screws won’t
interfere with sensitive equipment
• Connector “hood” closure cap seals
Replacement Closure Cap device when not in use
DESCRIPTION CAT. NO. TESTING & CODE COMPLIANCE
• Meet NEMA WD 1 & 6, ANSI
Replacement Connector Closure Cap for 30A devices 50W54 requirements
All locking devices are UL Listed. Also CSA certified except where indicated by★ • UL Listed & meets Fed. Spec. require-
ments: (File #13393)
• CSA Certified (File #LR-406)
• NOM Certified (#057)
• Backed by a Lifetime Warranty
2.75 (69.9 mm)

MATERIAL CHARACTERISTICS
2.53 (64.3 mm)

Environmental: Flammability, Rated V2


Operating Temperature: -40°C to 60°C

3.62 (92.0 mm)


5.52 (140.2 mm)
WETGUARD™ 30A LOCKING PLUG
WETGUARD™ 30A LOCKING CONNECTOR

For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World
J16
Non-NEMA Locking Devices

15 AMP Non-NEMA Locking Devices


15 AMP 125V/10A-250 3-Pole 3-Wire Non-Grounding Non-NEMA†
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 7582**
NON-
Locking Plug★ 7567-C* .245–.700 10–18 NEMA

Locking Connector†★ 7565-C* .245–.700 10–18


Locking Flanged Inlet★ 7556 NON-
NEMA
Locking Flanged Outlet★ 7557
†These devices are no longer UL Listed and are for replacement use only. Add (-G) for grounding version.
*Grounding (-G) version not available. For grounding connector, use Cat. No. 7555-G
7410-B **Uses stainless steel wallplate, Cat. No. 84004-40.

20 AMP Non-NEMA Locking Devices


20 AMP 250V AC/DC / 10 AMP 600V AC
4-Pole 5-Wire Grounding Non-NEMA
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 3520∆
Locking Plug, Black Nylon Body★ 3521-C .595–.895 10–18 NON-
NEMA
Locking Connector, Black 3523-C .595–.895 10–18
Nylon Body★
NON-
Locking Flanged Inlet★ 3524-C NEMA

Locking Flanged Outlet★ 3525-C

7411-C 20 AMP, 125V/250V 3-Pole 3-Wire Non-Grounding Non-NEMA††


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 7310-B∆
SPECIFICATIONS & FEATURES NON-
• Locking Receptacles feature a complete Locking Plug★ 9965-C .385–.780 10–18 NEMA
range of ratings and Non-NEMA configura- Locking Connector★ 7314-C .385–.780 10–18
tions, non-grounding
• Locking Plugs and Connectors feature Locking Flanged Inlet★ 3325-C NON-
heavy-duty construction for top performance NEMA
in the environmental extremes of grueling Locking Flanged Outlet★ 3326-C
industrial settings
• Flanged Inlets and Outlets are built to endure 20 AMP 3ØY 120V/208V 4-Pole 4-Wire Non-Grounding Non-NEMA††
hard use with rugged nylon flanges that
assure a smooth, flush fit and outstanding DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
resistance to cracking and breaking (inches) (stranded) CONFIG.
TESTING & CODE COMPLIANCE Single Flush Receptacle★ 7410-B∆
NON-
• All receptacles, plugs, connectors, inlets and Locking Plug★ 7411-C .595–.895 10–18 NEMA
outlets are designed to meet NEMA WD-6,
and ANSI C-73, and to meet/exceed UL 498 Locking Connector★ 7413-C .595–.895 10–18
standards Locking Flanged Inlet★ 7408-C NON-
• UL Fed Spec. Listed WC-596 (File #E-13399 NEMA
— Cat. Nos. 7582, 7557, 3520, 2525-C, Locking Flanged Outlet★ 7409-C
7310-B, 3326-C, 7410-B, 7409-C; File ††Effective July 1, 1981, rating for non-grounding versions was changed from 20A-250V AC/DC, 10A-600V AC to comply
#E-13393 — Cat. Nos. 7567-C, 7565-C,
7556, 3521-C, 3523-C, 3524-C, 9965-C, with UL requirements. Add (-G) for grounding devices: (-G) devices are rated 20A-250V AC/DC, 10A-600V AC and are
7314-C, 3325-C, 7411-C, 7413-C, 7408-C) no longer UL Listed — for replacement use only.
• CSA Certified (File #LR-406) For Corrosion Resistant Locking Devices, please check pages K2–K5
• NOM Certified (#057) ∆Uses stainless steel wallplate, Cat. No. 84020-40. For additional wallplate selections, please see Section G.
• Backed by a Lifetime Warranty Weather-Resistant Boots for 15A & 20A Locking Plugs and Connectors are listed on page J20
All devices are UL Listed. Also CSA certified except where indicated by★
MATERIAL CHARACTERISTICS
Environmental: Flammability per UL94 or CSA 1.13 (28.6 mm) 0.75 (19.0 mm)
C22/06 Requirements
Operating Temperature: -40°C to 60°C
2.70 (69.0 mm)
Ø 2.28 (57.94mm)
2.39 (60.7 mm)

2.38 (60.3 mm)

3.28 (83.3 mm)


3.62 (92.1 mm)

Ø 2.25 (57.15mm)
Ø 2.22 (56.0 mm)
(39.7 mm)

Ø 1.95 (50.0 mm)


Ø 1.56

PANEL OPENING
FOR ALL
20A / 30A
4 AND 5 WIRE
INLETS &
120

°
120

OUTLETS
°

1.43 (36.2 mm) 1.70 (43.3 mm)


TAP FOR #8-32 UNC SCREW
(3) PLACES
Ø 2.687 ± 0.01 SINGLE RECEPTACLE LOCKING PLUG
(68.25mm ± 0.3) Cat. No. 7410-B Cat. No. 7411-C

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World
J17
Non-NEMA Locking Devices

30 AMP Non-NEMA Locking Devices


30 AMP 125V/250 3-Pole 3-Wire Non-Grounding Non-NEMA†
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 3330**
Locking Plug★ 3331-C .385–.860 10–18
Locking Connector★ 3333-C .385–.860 10–18
Locking Flanged Inlet★ 3334-C NON-NEMA
Locking Flanged Outlet★ 3335-C
†EffectiveJuly 1, 1981, rating for non-grounding versions was changed from 30A-250V to comply with UL requirements.
Add (-G) for grounding devices: (-G) devices are rated 30A-250V and are no longer UL Listed — for replacement use only.
30 AMP 3ØY 120V/208V 4-Pole 4-Wire Non-Grounding Non-NEMA†† 3331-C
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle★ 3430**
Locking Plug★ 3431-C .595–.1.150 10–18
Locking Connector★ 3433-C .595–.1.150 10–18
Locking Flanged Inlet★ 3434-C NON-NEMA
Locking Flanged Outlet★ 3435-C
††Effective July 1, 1981, rating for non-grounding versions was changed from 30A-250V AC/DC, 30A-600V AC to comply
with UL requirements. Add (-G) for grounding devices: (-G) devices are rated 30A-250V AC/DC, 30A-600V AC and are no
longer UL Listed — for replacement use only.

50 AMP Non-NEMA Locking Devices


50 AMP 250V DC/600V AC 2-Pole 3-Wire Grounding Non-NEMA
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
3333-C
Single Locking Receptacle★ 3771*
Locking Plug★ 3763-C .680–.1.125 10–4 W
GR GR
W

Locking Connector★ 3762-C .680–.1.125 10–4 G G

NON-NEMA SPECIFICATIONS & FEATURES


Locking Flanged Inlet★ 3777
• Locking Receptacles feature a complete
range of ratings and Non-NEMA configura-
50 AMP 250V DC/600V AC 3-Pole 4-Wire Grounding Non-NEMA tions, including isolated ground and non-
grounding
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG. • Locking Plugs and Connectors feature
heavy-duty construction for top performance
Single Locking Receptacle★ 7379* X X
in the environmental extremes of grueling
GR GR
industrial settings
Locking Plug★ 7765-C .680–.1.125 10–4 Z Z

Y Y
• Flanged Inlets and Outlets are built to endure
Locking Connector★ 7764-C .680–.1.125 10–4 NON-NEMA hard use with rugged nylon flanges that
assure a smooth, flush fit and outstanding
50 AMP 250V DC/600V AC 3-Pole 4-Wire Grounding Non-NEMA resistance to cracking and breaking

DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA TESTING & CODE COMPLIANCE
(inches) (stranded) CONFIG. • All receptacles, plugs, connectors, inlets and
Single Locking Receptacle★ 3769* outlets are designed to meet NEMA WD-6,
and ANSI C-73, and to meet/exceed UL 498
Locking Plug★
Y Y
3765-C .680–.1.125 10–4 X X
standards
Locking Connector★ 3764-C .680–.1.125 10–4 W
GR GR
W • UL Fed Spec. Listed WC-596 (File #E-13399
— Cat. Nos. 3330, 3335-C, 3530, 3535-C,
Locking Flanged Inlet★ 3775 NON-NEMA
3771, 7379, 3769; File #E-13393 — Cat.
Nos. 3331-C, 3333-C, 3334-C, 3431-C,
3433-C, 3434-C, 3763-C, 3762-C, 3777,
Receptacle Cover 7765-C, 7764-C, 3765-C, 3764-C, 3775)
• CSA Certified (LR-406)
DESCRIPTION CAT. NO. • NOM Certified (#057)
Weather-protective die-cast aluminum receptacle cover 7770 • Backed by a Lifetime Warranty
with lift lid for Cat. Nos. 3769, 3771 and 7379★
MATERIAL CHARACTERISTICS
*Uses Weatherproof Cover, Cat. No. 7788-CR or 7770.
Environmental: Flammability per UL94 or CSA
For Corrosion Resistant Locking Devices, please check pages K2–K5. C22/06 Requirements
Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page J20. Operating Temperature: -40°C to 60°C
**Uses stainless steel wallplate, Cat. No. 84020-40. For additional wallplate selections, please see Section G.
All devices are UL Listed. Also CSA certified except where indicated by★ Ø 2.28 (57.94mm)
Ø 2.25 (57.15mm)
2.48 (63.0 mm) 3.53 (90.0 mm) PANEL OPENING
FOR ALL
Ø 2.08 (52.8 mm)

20A / 30A
Ø 1.83 (46.0 mm)
Ø 1.84 (47.0 mm)

2.08 (52.8 mm)

4 AND 5 WIRE
INLETS &
120

°
120

OUTLETS
°

TAP FOR #8-32 UNC SCREW


(3) PLACES
LOCKING PLUG LOCKING CONNECTOR Ø 2.687 ± 0.01
Cat. No. 3331-C Cat. No. 3333-C (68.25mm ± 0.3)

For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World
J18
Non-NEMA Locking Devices

50 AMP “California Style” CS Non-NEMA Locking Devices


50 AMP 125V 2-Pole 3-Wire Grounding Non-NEMA
DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
Single Locking Receptacle★ CS63-70*
Locking Plug★ CS63-61C .680–1.125 10–4 W W

Locking Connector★ CS63-60C .680–1.125 10–4 G G

Locking Flanged Inlet★ CS63-77 NON-NEMA

50 AMP 250V 2-Pole 3-Wire Grounding Non-NEMA


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
CS63-70 (inches) (stranded) CONFIG.
Single Locking Receptacle★ CS82-69*
Locking Plug★
W
CS82-65C .680–1.125 10–4 Y W

Locking Connector★ CS82-64C .680–1.125 10–4 GR G

Locking Flanged Inlet★ CS82-75 NON-NEMA

50 AMP 125/250V 3-Pole 4-Wire Grounding Non-NEMA


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
Single Locking Receptacle★ CS63-69*
Y Y
Locking Plug★ CS63-65C .680–1.125 10–4 X
EQ GR EQ GR
X

Locking Connector★ CS63-64C .680–1.125 10–4 W W

Locking Flanged Inlet★ CS63-75 NON-NEMA

CS63-60C 50 AMP 3Ø 250V AC 3-Pole 4-Wire Grounding Non-NEMA


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
Single Locking Receptacle★ CS83-69*
SPECIFICATIONS & FEATURES
Locking Plug★ X X
CS83-65C .680–1.125 10–4 Y
EQ GR EQ GR
Y

• All-nylon construction that takes punishment


and continues to perform Locking Connector★ CS83-64C .680–1.125 10–4 Z Z

• Patented strain relief that provides maximum Locking Flanged Inlet★ CS83-75 NON-NEMA
holding power
• Tight-fitting gaskets to seal out dust
• Easy identification of ratings
50 AMP 480V 2-Pole 3-Wire Grounding Non-NEMA
• Color-Coded large wire pockets and terminal DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
screws (inches) (stranded) CONFIG.
• Corrosion-resistant devices feature added Single Locking Receptacle★ CS84-69*
plating Y Y

Locking Plug★ CS84-65C .680–1.125 10–4 X X

Locking Connector★
G G
TESTING & CODE COMPLIANCE CS84-64C .680–1.125 10–4
• Non-NEMA devices meet/exceed UL 498 NON-NEMA
Locking Flanged Inlet★ CS84-75
standards
• UL Fed Spec. Listed WC-596 (File #E-13399
— Cat. Nos. CS63-70, CS82-69, CS63-69, 50 AMP 3Ø 480V AC 3-Pole 4-Wire Grounding Non-NEMA
CS83-69, CS84-69, CS81-69; File #E-13393
— Cat. Nos. CS63-61C, CS63-60C, DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
CS63-77, CS82-65C, CS82-64C, CS82-75, (inches) (stranded) CONFIG.
CS63-65C, CS63-64C, CS63-75, CS83-65C,
CS83-64C, CS83-75, CS84-65C, CS84-64C, Single Locking Receptacle★ CS81-69* Y Y

CS84-75, CS81-65C, CS81-64C, CS81-75) Locking Plug★ CS81-65C .680–1.125 10–4 EQ GR


X X
EQ GR
• NOM Certified (#057)
Locking Connector★ CS81-64C .680–1.125 10–4 Z Z

• Backed by a Lifetime Warranty NON-NEMA


Locking Flanged Inlet★ CS81-75
MATERIAL CHARACTERISTICS *Uses Weatherproof Cover, Cat. No. 7788-CR or 7770.
Environmental: Flammability per UL94 or CSA For Corrosion Resistant Locking Devices, please check pages K2–K5
C22/06 Requirements
All devices are UL Listed. Also CSA certified except where indicated by★
Operating Temperature: -40°C to 60°C

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World
J19
Weather-Resistant Boots

Boots for 15 AMP Industrial Locking Plugs and Connectors


DESCRIPTION CAT. NO.
Locking Plug Boot, Black Thermoplastic Elastomer 6017-L
Locking Plug Boot, High-Visibility Yellow Thermoplastic Elastomer 6017-LY
Locking Connector Boot, Black Thermoplastic Elastomer 6018-L
Locking Connector Boot, High Visibility Yellow Thermoplastic Elastomer 6018-LY

Boots for 3-Wire 20 AMP & 30 AMP


Industrial Locking Plugs and Connectors
DESCRIPTION CAT. NO.
3-wire Locking Thermoplastic Elastomer Plug Boot, Black 6031
6017-LY
3-wire Locking Thermoplastic Elastomer Plug Boot, High Visibility Yellow 6031-Y
3-wire Locking Thermoplastic Elastomer Connector Boot, Black 6032
3-wire Locking Thermoplastic Elastomer Connector Boot, High Visibility Yellow 6032-Y

Boots for 4 and 5-Wire 20 AMP & 30 AMP


Industrial Locking Plugs and Connectors
DESCRIPTION CAT. NO.
4 & 5-wire Locking Thermoplastic Elastomer Plug Boot, black 6033
4 & 5-wire Locking Thermoplastic Elastomer Plug Boot, High Visibility Yellow 6033-Y
4 & 5-wire Locking Thermoplastic Elastomer Connector Boot, black 6034
4 & 5-wire Locking Thermoplastic Elastomer Connector Boot, 6034-Y
High Visibility Yellow

6032

SPECIFICATIONS & FEATURES


• Feature a triple seal action to protect straight
blade and locking plugs and connectors
against dirt and moisture in harsh applications
• Plug and connector boots available in black
and high-visibility yellow
• Fluted surface and grip-ring design provide a
non-slip grip even in wet conditions

WARRANTY
• Backed by a Lifetime Warranty

MATERIAL CHARACTERISTICS
Environmental: Flammability, Rated HB
Ø 2.00 (50.8 mm) 2.73 (69.4 mm) Operating Temperature: -40°C to 90°C
LOCKING PLUG BOOT
Cat. No. 6017-L

Ø 2.81 (71.4 mm) 4.92 (125.0 mm) Ø 2.96 (75.1 mm) 5.16 (131.0 mm)

3-WIRE LOCKING CONNECTOR BOOT 4 & 5-WIRE LOCKING CONNECTOR BOOT


Cat. No. 6032 Cat. No. 6034

For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World
J20
Locking Power
Interrupting Devices

20 AMP 125V 2-Pole 3-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
Single Flush Receptacle *23000-HG W Y
with a Thermoset body GR GR

Locking Connector *23001-HG .250–.656 B X

RECEPTACLE
Locking Plug *23004-HG

20 AMP 125V 2-Pole 3-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
23000-HG Single Flush Receptacle 23030 W Y

GR GR

Locking Connector 23031-A .256–.656


B X

Locking Plug 23034-A RECEPTACLE

30A-600VAC / 20AMP – 250V DC 3-Pole 4-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
X
Single Flush Receptacle 20403 X

GR GR

Locking Connector 21414-B .360–.484 Y Y

Locking Plug 21415-B RECEPTACLE

30A-600VAC / 20AMP – 250V DC 4-Pole 5-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NON-NEMA
(inches) (stranded) CONFIG.
Single Receptacle
with Fiberglass Reinforced 25403
Nylon Interior with Cast Iron Z Z

and Steel Shell. Y


W W
Y

Fits FS or FD boxes GR X X
EQ GR

RECEPTACLE
Locking Connector 25414-B .625–1.0
Locking Plug 25415-B
*UL listed for “HOSPITAL USE ONLY” applications in non-hazardous locations
For appropriate wallplates for listed receptacles, please see Section G.
All devices are UL Listed and CSA certified.

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World
J21
Midget Locking Devices

15 AMP 125V 2-Pole 2-Wire Non-Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Midget Locking Plug ML1-P .218–.43 18–14
Angle Plug ML1-AP .218–.43 18–14
Midget Locking Connector ML1-C .218–.43 18–14
Angle Connector ML1-AC .218–.43 18–14 W W

Plastic Midget Locking ML1-PB


Flanged Inlet
Plastic Midget Locking ML1-PER NEMA ML1

Flanged Outlet
Metal Inlet ML1-MB
ML1-P
Metal Outlet ML1-MER

15 AMP 125V 2-Pole 3-Wire Grounding


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA
(inches) (stranded) CONFIG.
Midget Locking Plug ML2-P .218–.43 18–14
Angle Plug ML2-AP .218–.43 18–14
Midget Locking Connector ML2-C .218–.43 18–14
Angle Connector ML2-AC .218–.43 18–14 W
W

Plastic Midget Locking ML2-PB G G

Flanged Inlet
Plastic Midget Locking ML2-PER NEMA ML2
Flanged Outlet
Metal Inlet ML2-MB
Metal Outlet ML2-MER ML1-C

15 AMP 125/250V 3-Pole 3-Wire Non-Grounding★


DESCRIPTION CAT. NO. CORD DIA. WIRE GAUGE NEMA SPECIFICATIONS & FEATURES
(inches) (stranded) CONFIG. • Offer a smaller form factor for limited-space
Midget Locking Plug ML3-P .218–.43 18–14 applications
• Locking Plugs and Connectors feature
Angle Plug ML3-AP .218–.43 18–14 heavy-duty construction for top performance
Midget Locking Connector ML3-C .218–.43 18–14 in the environmental extremes of grueling
industrial settings
Angle Connector ML3-AC .218–.43 18–14 • Flanged Inlets and Outlets are built to endure
X
Plastic Midget Locking ML3-PB X
hard use with rugged nylon flanges that
Flanged Inlet W W assure a smooth, flush fit and outstanding
Y Y resistance to cracking and breaking
Plastic Midget Locking ML3-PER
NEMA ML3
Flanged Outlet TESTING & CODE COMPLIANCE
Metal Inlet ML3-MB • All receptacles, plugs, connectors, inlets and
outlets are designed to meet NEMA WD-6,
Metal Outlet ML3-MER and ANSI C-73, and to meet/exceed UL 498
standards
15 AMP 125V 2-Pole 2-Wire Non-Grounding • UL Fed. Spec. Listed WC-596 (File No.
E-13393)
DESCRIPTION CAT. NO. PLUG CAT. NO. ANGLE PLUG NEMA • CSA Certified (File No. LR-406)
CONFIG. • NOM Certified (#057)
Midget Straight Blade Plug MS2-P MS2-AP • Backed by a Lifetime Warranty
Black & White Nylon NEMA MS2-P W
MATERIAL CHARACTERISTICS
Environmental: Flammability per UL94 or CSA
All devices are UL Listed. Also CSA certified except where indicated by★ C22/06 Requirements
Operating Temperature: -40°C to 60°C

2.34 (59.5 mm) 1.88 (47.7 mm)


Ø 1.26 (32.0 mm)
Ø 1.26 (32.0 mm)

1.13 (28.6 mm)

1.13 (28.6 mm)

MIDGET LOCKING CONNECTOR MIDGET LOCKING PLUG


Cat. No. ML2-C Cat. No. ML2-P

For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World
J22
Combination Locking & Straight
Blade/Integrated Inlets & Outlets

Combination Locking and Straight Blade Duplex Receptacle


15 AMP 125V 2-Pole 3-Wire Grounding Back and Side Wired
DESCRIPTION CAT. NO. NEMA CONFIG.
Duplex Combination Locking & Straight Blade 4792 W
Receptacle with Common Feed
L5-15R
Duplex Combination Locking & Straight Blade 4794-1R G

Receptacle with 2 Hot Feeds, 1 Neutral Return


Duplex Combination Locking & Straight Blade 4795-2R 5-15R
G
W
Receptacle with Split Feed — 2 Hot Feeds,
2 Neutral Returns

4792
Integrated Power Inlets and Outlets with
Weather-Resistant Covers
■ Engineered to IP 64 and NEMA 3R Protection Ratings
■ Suitable for Industrial Indoor and Outdoor Use

Integrated Power Inlets and Outlets with Weather-Resistant Covers


Gray, Glass-Filled Thermoplastic Cover and White, Nylon Device
DESCRIPTION CAT. NO. FLANGED INLET CAT. NO. FLANGED OUTLET
Standard Wire Wells, 4716-CWP 4715-CWP
15A-125V 2-Pole, 3-Wire W
W

NEMA L5-15P NEMA L5-15R


G G

4716-CWP
Slots for Fork Terminals, 4716-FWP 4715-FWP
15A-125V 2-Pole, 3-Wire W
W

NEMA L5-15P NEMA L5-15R


G G

Standard Wire Wells, 4586-CWP 4585-CWP


SPECIFICATIONS & FEATURES 15A-250V 2-Pole, 3-Wire X X

NEMA L6-15P G NEMA L6-15R G


Combination Devices Y Y

• Impact-resistant black thermoplastic nylon


face and body All devices are UL Listed and CSA Certified.
• Smooth face does not collect dirt Note: For straight blade configurations, please see Section H.
• Large, triple-wipe brass “T” contacts for
superior contact and conductivity
• Triple-combination terminal screws
• Back and side wire options accept #10–#14
AWG stranded or solid wire 1.88
Integrated Devices (46.6 mm)
0.13
• Glass-filled thermoplastic cover and plate 1.18 1.44 (3.2 mm)
provide outstanding impact resistance and (30.0 mm) (36.4 mm)
durability
• Dual gaskets, one under plate and one under
lid, for weather-resistant fit
• Stainless steel external hardware resists
4.06 (103.2 mm)

corrosive effects of moisture


3.28 (83.3 mm)
2.77 (70.4 mm)

(42.8 mm)

(52.96 mm)

(115.9 mm)
(82.6 mm)

• Large thumb-tab makes it easy to open cover


2.085
1.69

3.25

4.56

with gloved hand


• Mounts to panels or FS/FD boxes
• UL Listed and CSA Certified for wet locations
with cover closed

TESTING & CODE COMPLIANCE


Combination Devices
• UL Listed (File #E-13393)
• CSA Certified (File #LR-406) COMBINATION LOCKING AND STRAIGHT 1.49 1.33
• NOM Certified (#057) BLADE DUPLEX RECEPTACLE (37.8 mm) (33.8 mm) 2.84
• Backed by a Limited 10-Year Warranty (72.2 mm)
Integrated Devices
INTEGRATED LOCKING POWER INLETS AND OUTLETS
• UL Listed (File #E-13397) MATERIAL CHARACTERISTICS WITH WEATHER-RESISTANT COVERS
• CSA Certified (File #LR-16347) Combination Devices
• NOM Certified (#057) Environmental: Flammability, Rated V2
• IP 64 Suitability Rating (protected against Operating Temperature: -40°C (without impact)
dust and splashing water) to 60°C maximum continuous
• NEMA Type 3R Enclosure Rating when prop- Integrated Devices
erly installed (protected against rain, sleet Environmental: VO Flammability Rating
and damage from external ice formations) per UL 94
• Backed by a Limited 2-Year Warranty Operating Temperature: -40°C to 60°C

To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World