Sie sind auf Seite 1von 16

One Way Cassette Fan Coil Unit

Bueco Air Conditioning Co., Ltd.


About us

Bueco Co., Ltd. is established by Mr. Wang, Mr. Ouyang and an excellent engineers' team
who is in leading companies of HVAC business for more than a decade in July 2016.

We focus on the air cooled water chiller, air source heat pump, water cooled water chiller,
ground source heat pump, air handling unit, fan coil unit, rooftop packaged unit, cooling
tower and other HVAC accessories. We have two workshops, total 30000 m2 workshop
area, one for chiller of big size, and another for rooftop packaged unit and chiller of small
size, and two laboratories, one is specially for the water chiller, another for the rooftop
packaged unit etc., all the parameter and performance can be tested. All products will be
tested before delivery.

The product quality is controlled with excellent engineer team, production workers and
testing facilities, and the production equipment is also important, our CNC machine, fin
punching machine etc., are imported from Amada, Japan, which give high precision of
process and quick production speed.

We got the national 1st level qualification license on mechanical, electrical equipment
installation, 2nd level qualification license on air purification engineering. The company is
ISO9001, ISO14001, QHSAS18001 certified. Our products have the National Certificate
of Refrigeration Equipment Production, 3C China Compulsory Certificate, CRAA China
Refrigeration Industry Performance Certificate and air handling unit is AHRI certified.

With the conception, customer first and quality first, Bueco is striving for the technology
creation and cost optimization.

Thanks for the trust and supports of our clients, Bueco has been widely delivered to
domestic market and international market such as Algeria, Nigeria, Ethiopia, Angola,
South Africa, Indonesia, Cambodia, Philippines, Thailand, Malaysia, South Korea, Japan,
Pakistan, India, Sri Lanka, Mongolia , France, USA etc..
Certificates (CE, AHRI)
Contents
1

Description

Features

Model

Options

Specification

Dimension

Maintenance
Product Overview

BCF-K1 series cassette fan coil unit is a one way cassette fan coil unit, with remote controller, built in
condensed water pump, which is popular in different buildings.

Product features

1. One Way air flow, which is easy to be installed in the side of ceiling

2. Slim body can be installed in limited space ( Body thickness is 235mm)

Partial ceiling Full ceiling Narrow space

3. Remote controller is standard device, wired controller is optional.

1
4. Auto swing, wide air flowing range, air flowing height up to 3.5m, air delivery angle up to 50o.

5. Horizontal air diffuser can be adjusted by manual.

6. Quiet running
Using double axial extension fan, operation is more stable.

7. High lift water drained pump (750mm), easy to plan the condensed water drain pipe.

8. Water level switch inside to keep away leakage


After the water raising to a certain position, the float switch will act and alarm, then the unit will cut off
the water valve or stop the fan motor.

2
9. Fresh air can be input from outside
Fresh air inlet can intake some fresh air from outside and ensure the indoor air quality. The user can share
the fresh and clean air to lessen illness caused by air conditioner.

10. Easy installation, low installation cost


No air ducting required, comparing with concealed duct fan coil unit.

11. Fan and fan motor is easy to maintain

12. Easily interfaced with most widely used Modbus and BMS.

13. The water inlet/outlet connection direction (left or right) can be customized.

To distinguish the water inlet/water outlet pipe of the fan coil unit, will reduce the working hours of
piping layout and optimize the space.

3
14. Negative ion generator is optional.

15. 4tubes system is optional


There are both cooling and heating water coils inside the unit, so the unit can deal with cooling or heating
at the same time.

16. Water valve can be installed inside of the unit.

4
Nomenclature

VCF 68 K 1

Bueco FCU

Air flow rate


6 8 x 1 0 m 3/ h

Cassette type
One way

Optional Accessories

★ Electrical heater ★ water valve ★ stainless steel hose

★ 4tubes design

Specification (Two pipes series)

Model Unit Unit BCF34K1 BCF51K1 BCF68K1 BCF85K1


Power supply 220V, 1Ph, 50Hz
H 340 510 680 850
Air flow
M m3/h 280 380 515 660
rate
L 180 260 340 430
ESP Pa 0 0 0 0
TH W 1800 2700 3600 4500
H
SH W 1300 1970 2700 3184
Cooling TH W 1500 2460 3000 3715
M
capactiy SH W 1000 1555 1995 2420
TH W 1390 2057 2479 2920
L
SH W 823 1200 1530 1825
H W 2700 4050 5400 6750
Heating
M W 1950 2770 3935 4900
capacity
L W 1290 1774 2800 3505
Noise dB(A) 37 39 41 43
Power High
W 37 52 62 76
input speed
3
water flow m /h 0.31 0.46 0.62 0.77
Presure drop Kpa 10.8 10.8 20 20
Water inlet pipe inch ZG3/4" ZG3/4" ZG3/4" ZG3/4"
Water outlet pipe inch ZG3/4" ZG3/4" ZG3/4" ZG3/4"
Coil type Cu/Al Cu/Al Cu/Al Cu/Al
Max. working pressure Mpa 1.6 1.6 1.6 1.6
Drain pipe dia. mm φ26 φ26 φ26 φ26
L mm 971 971 971 971
Unit
W mm 413 413 413 413
Dimension
H mm 236 236 236 236
L mm 1044 1044 1044 1044
Panel
W mm 468 468 468 468
Dimension
H mm 31 31 31 31
Net weight kg 26 26 27 27

5
Specification (Four pipes series)

Model Unit Unit VCF34K1 VCF51K1 VCF68K1 VCF85K1


Power supply 220V, 1Ph, 50Hz
H 340 510 680 850
Air flow rate M m3/h 280 380 515 660
L 180 260 340 430
ESP Pa 0 0 0 0
TH W 1350 2030 2700 3380
H
SH W 1000 1520 2080 2450
Cooling TH W 1130 1850 2250 2790
M
capactiy SH W 770 1200 1540 1860
TH W 1040 1540 1860 2190
L
SH W 630 920 1180 1410
H W 1080 1620 2160 2700
Heating
M W 780 1108 1574 1960
capacity
L W 516 710 1120 1402
Noise dB(A) 37 39 41 43
High speed
Power input W 37 52 62 76
Water Flow Rate (cooling coil)
m3/h 0.23 0.35 0.46 0.58
(H)
Water Flow Rate (cooling coil)
m3/h 0.09 0.14 0.19 0.23
(H)
Pressure drop (cooling /heating
Kpa 7/4.2 7.3/4.4 13/7.5 14.6/8.7
coil)
Water inlet pipe inch ZG3/4" ZG3/4" ZG3/4" ZG3/4"
Water outlet pipe inch ZG3/4" ZG3/4" ZG3/4" ZG3/4"
Coil type Cu/Al Cu/Al Cu/Al Cu/Al
Max. working pressure Mpa 1.6 1.6 1.6 1.6
Drain pipe dia. mm φ26 φ26 φ26 φ26
L mm 971 971 971 971
Unit
W mm 413 413 413 413
Dimension
H mm 236 236 236 236
L mm 1044 1044 1044 1044
Panel
W mm 468 468 468 468
Dimension
H mm 31 31 31 31
Net weight kg 26 26 27 27

Note:

Nominal condition:(Return air):


■Standard cooling condition: Entering air DB 27℃,WB 19.5℃;
■Entering chilled water temp. 7℃, Leaving chilled water temp. 12℃;
■Standard heating condition: Entering air DB 21℃;
■ Entering hot water temp. 60℃.

6
Unit Dimension

Left Pipe Connection

Ceiling

BCF34K1
BCF51K1
Description Mark Unit
BCF68K1
BCF85K1
Distance from hook to ceiling A1 mm 205-210
Distance from hook to top of unit A2 mm 31
Hooks distance 1 A3 mm 891
Hooks distance 2 A4 mm 341
Unit Length B1 mm 971
Unit Width B2 mm 413
Unit Body Thickness B3 mm 236
Ceiling Opening Length C1 mm 990
Ceiling Opening Width C2 mm 426
Panel Length C3 mm 1044
Panel Width C4 mm 468
Panel Thickness C5 mm 31
Pipe Position 1 D1 mm 94
Pipe Position 2 D2 mm 74
Pipe Position 3 D3 mm 57
Pipe Position 4 D4 mm 34
Condensed water pipe position 1 E1 mm 122
Condensed water pipe position 2 E2 mm 41

7
Unit Dimension

Right Pipe Connection

Ceiling

BCF34K1
BCF51K1
Description Mark Unit
BCF68K1
BCF85K1
Distance from hook to ceiling A1 mm 205-210
Distance from hook to top of unit A2 mm 31
Hooks distance 1 A3 mm 891
Hooks distance 2 A4 mm 341
Unit Length B1 mm 974
Unit Width B2 mm 413
Unit Body Thickness B3 mm 236
Ceiling Opening Length C1 mm 990
Ceiling Opening Width C2 mm 426
Panel Length C3 mm 1044
Panel Width C4 mm 468
Panel Thickness C5 mm 31
Pipe Position 1 D1 mm 80
Pipe Position 2 D2 mm 116
Pipe Position 3 D3 mm 26
Pipe Position 4 D4 mm 61
Condensed water pipe position 1 E1 mm 122
Condensed water pipe position 2 E2 mm 41

8
Installation and maintenance

Installation
Take out the unit’s manual and packaging list before the installation. Check the product’s model and
the components as well as the shell. Open the access door and turn the fans with hand, if there is any collision
sound, tackle the problem in time.

Heat exchanger adopts up-in & down-out style (water inlet at down side and water outlet at the up
side). The pipeline needs exclusive supporter, and not to allow it bear the weight of unit. Stop valve should be
equipped on water inlet pipe and outlet pipe to adjust water flow or turn off it in maintenance. Equip filter at
inlet pipe to discharge sundries, equip air discharge valve at the highest point of system and water discharge
valve at the lowest point. The lowest pipe is the drain pipe for condensed water, which should be connected
with U type pipe before the sewer, because of the negative pressure factor. (Refer the water sealing diagram)

There should be flexible connection between pipes and the unit, and exclusive supporter should be
provided to the pipe, not to allow it bear the weight of unit.

Maintenance

Drain out the water completely, and blow all the water in coil with compressed air to avoid damage
caused by freezing when no running the machine in winter.
Fill the coil with water when in season not in use, to reduce rusting, and it must be completely drained out
to avoid damage caused by freezing in winter.
Water within the system should be clean, and it’s better to be dematerialized water.

9
Remarks

10
BUECO AIR CONDITIONING CO., LTD.
Office: Room No. 521, Huaxin Road No. 2, Licheng District, Jinan, Shandong, China
Factory: Tianqu Industrial Park, Dezhou, Shandong, China
Tel: 0086 531 86955489
Mob: 0086 13708931818
Email: export@bueco.com.cn
www.bueco.com.cn

Das könnte Ihnen auch gefallen