Beruflich Dokumente
Kultur Dokumente
Technical features
Medium: Flow: Life expectancy: Materials:
Air, oxygen, neutral gases 5 … 32 l/min at 2 bar (29 psi) ≥100 Mio. cycles for 1 W valves Body: PPS
(10 % ... 95 % humidity, non at +20 °C (+68°F) Weight: Seat seals: FPM, NBR, EPDM
condensing), 40 μm filtered Mounting: 10,5 g (0.023 lbs) Internal parts: Stainless steel, PAA
Operation: Manifold Ambient/media temperature:
Direct acting 2-way and 3-way Orifice: -10 ... +50 °C (+14 ... +122°F)
valves, normally closed and 0,6 .... 2 mm Air supply must be dry enough
normally opened Response time: to avoid ice formation at
Operating pressure: 10 ... 15 ms temperatures below +2 °C (+35°F).
0 ... 10 bar (0 ... 145 psi) Response time measured
Details on page 2 according to ISO 12238
Our policy is one of continued research and development. We therefore reserve the right to amend, without 4/15
notice, the specifications given in this document. (2006 - 5017d) © 2015 Fluid Automation Systems s.a. en 5.2.030.01
FAS 10 mm PICOSOL
Direct acting solenoid valve
122 32 100 0,6 0 ... 10 0 ... 145 0,12 1 24 With FPM 2 11-221PI060H1+1111+AYV
2/2 NO
(3/2 mounting 1,1 0 ... 4 0 ... 58 0,3 1 24 With FPM 2 11-221PI011H1+1111+AYR
21 pattern)
*1) Cv = 0,07 kv
*2) Power consumption: “boosting power during ca. 50 ms”/ “holding power”
*3) Push only
Our policy is one of continued research and development. We therefore reserve the right to amend, without
en 5.2.030.02 notice, the specifications given in this document. (2006 - 5017d) © 2015 Fluid Automation Systems s.a. 4/15
FAS 10 mm PICOSOL
Direct acting solenoid valve
6,4
2,54 2
18,5
32
23
A
7
3
12,4 6,2
4
2,6
A
10
3,5 22,7 1
1,9
M2
3,9
8,5
2
4,5
2
2
6,4
2,54 2
18,5
32
23
A
6,2
3
12,4 6,8
4
A
10
M1,6
0,2
3,5 22,7
3
2,7 2,7
2
1
1,6
0,8
2,4
2 4
Our policy is one of continued research and development. We therefore reserve the right to amend, without
4/15 notice, the specifications given in this document. (2006 - 5017d) © 2015 Fluid Automation Systems s.a. en 5.2.030.03
FAS 10 mm PICOSOL
Direct acting solenoid valve
Mounting plate with barbed fittings for Mounting manifold Dimensions shown in mm
Projection/First angle
3 mm ØID tubing (up to 2 bar) Model: S110.1277
Model: S111.1772
14,5 1
A
6,5 2
3
15
10,5
2
2,6
2 9
7
R
3 1
6,5
M5 10,5 5
3
5,5
10
A
M5
20
12
5,5
5 M5
ø1,8
ø3,6
13
Mounting manifold
Model: on request
M5 M5
20
14
4,5
5 6 10,5 ±0,1
8 (N-1) x 10,5
5
3
15
3
X
Y
M5
10,5
Valve station X Y
2 16,5 22,5
3 27 33
4 37,5 43,5
5 48 54
6 58,5 64,5
7 69 75
8 79,5 85,5
Our policy is one of continued research and development. We therefore reserve the right to amend, without
en 5.2.030.04 notice, the specifications given in this document. (2006 - 5017d) © 2015 Fluid Automation Systems s.a. 4/15
FAS 10 mm PICOSOL
Direct acting solenoid valve
2,54 15
5
Warning
These products are intended for use in air, oxygen and neutral gas The system designer is warned to consider the failure modes of all
systems only. Do not use these products where pressures and component parts used in fluid power systems and to provide adequate
temperatures can exceed those listed under »Technical features«. safeguards to prevent personal injury or damage to equipment in the
event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in the system
for non-industrial applications, life-support systems, or other instructional manual if protection against a failure mode cannot be
applications not within published specifications, consult IMI FAS. adequately provided.
Our policy is one of continued research and development. We therefore reserve the right to amend, without
4/15 notice, the specifications given in this document. (2006 - 5017d) © 2015 Fluid Automation Systems s.a. en 5.2.030.05