Concrete C30/37:
fck 30MPa Characteristic compressive strength.
kN
ρ c 25 Unity self-weight of prestressed concrete.
3
m
fp01k
fpd 1387.909 MPa Design value of steel strength.
γs
5 Young's modulus.
Ep 1.9 10 MPa
2
Anominal 150mm Nominal area of the strand.
2
Ap ns Anominal 1650 mm Cross sectional area of a tendon.
ϕduct 50mm
Diameter of the ducts.
D-2
D - Fatigue Limit State design for the prestressed concrete tower
20 4 290
40 4.75 360
h 60 m ϕouter 5.25 m t 420 mm
80 6 460
100 6.5 500
ϕouter
router Outer radius of the cylinder.
2
ϕinner
rinner Inner radius of the cylinder.
2
t
rtower router Radius of the cylinder medium section.
2
Ag π router rinner
2 2
Total area of the cross section.
2
As Ap np 92400 mm Steel area of the cross section.
Loads
Ff 0.1 1000kN 100000 N Horitzontal fatigue load coming from the wind.
2 106
4 106
Mz Ff h 6 106 N m Bending moment produced by the fatigue load.
8 106
6
10 10
D-3
D - Fatigue Limit State design for the prestressed concrete tower
Mz
σ c Compressive stress in the concrete section
0.5 x b z exposed to cyclic loading. [31]
2
x d α ρ 1 1 Distance to the neutral layer. [31]
α ρ
d is the distance between bottom and top reinforcement. Since the tower has a circular section,
d has not a constant value. For this reason an average distance has been considered:
ϕouter
xg 2
3 π
The average value adopted for parameter d corresponds to the distance between the tendons which
are situated in the centroid of the semicircle.
3359.289
3975.007
4 r
d 2 sin acos tower 4373.414 mm
3 π 5016.296
5432.812
Ep
α 5.938 Ratio between stiffness of the reinforcement
Ecm and the concrete.
As
ρ Reinforcement ratio.
Ac
5356.16
6854.17
2
x d α ρ 1 1 7999.545 mm
α ρ Distance to the neutral layer. [31]
9182.659
10117.565
D-4
D - Fatigue Limit State design for the prestressed concrete tower
x
z d Inner lever.
3
0.076
0.142
Mz Maximum compressive stress at a fibre.
σ c.max 0.211 MPa
0.5 x b z EN 1992-1-1 6.8.7 (2)
0.246
0.291
0
0 Minimum compressive stress at the same
fibre where σc.max occurs. If σc.min<0,
σ c.min 0 MPa then σc.min = 0.
0 EN 1992-1-1 6.8.7 (2)
0
1
1
σ c.max σ c.min
Verification1 0.5 0.45 1 EN 1992-1-1 6.8.7 (6.77)
fcd.fat fcd.fat
1
1
1
1
σ c.min
Verification2 0.5 0.45 0.9 1 EN 1992-1-1 6.8.7 (6.77)
fcd.fat
1
1
D-5
D - Fatigue Limit State design for the prestressed concrete tower
6
Ncycles 10
k1 5
k2 10
Δσ Rsk 150MPa
6
ncycles 800 10
Number of cycles of wind tower service life.
Δσs at ncycles is found by interpolation of the graph showed in EN-1-1 6.8.4 Figure 6.30
m atan
1 0.1
k2
n log ncycles Ncycles 8.903
p n tan ( m ) 0.89
13.752
25.611
Mz
σ s 38.043 MPa Half of the steel stress considereing one
As z
44.277 direction of the cyclic load.
52.529
27.505
51.222
Δσ s.r 2 σ s 76.085 MPa Maximum steel stress under cyclic load.
88.554
105.058
1
1
Verification3 Δσ s Δσ s.r 1 EN 1992-1-1 6.8.5 (6.7.1)
1
1
D-6