Sie sind auf Seite 1von 7

VOYAGER™ 1202G BARCODE READER

HYPERION 1300G BARCODE READER


Installation and configuration

July 2012

Edition 1

510166 AA

lectra.com 1/7
VOYAGER™ 1202G BARCODE READER
HYPERION 1300G BARCODE READER
Installation and configuration

PREFACE

Copyright
© LECTRA 2010-2012. All Rights Reserved. Any copying, reproduction or translation of all or part of the
contents of this document without the express written permission of LECTRA is strictly forbidden by the
provisions of copyright laws.

Guarantees
LECTRA reserves the right to modify, without prior notice, information relating to its products in order to
improve their reliability or operating capacity.
Publication does not imply that the contents are free of industrial patent rights and does not grant
permission in any other respect to those rights. LECTRA assumes no liability for the consequences of
using this information in any way whatsoever.
Performances and other data appearing in this documentation are approximate and have no contractual
value.

Registered trademarks
Voyager™ is a registered trademark of Honeywell International Inc, USA.

Update monitoring

Edition Purpose of the update Pages modified

Edition 1
Creation of the document
July-2012

July 2012 – 510166 AA lectra.com 2/7


VOYAGER™ 1202G BARCODE READER
HYPERION 1300G BARCODE READER
Installation and configuration

Purpose of the document

This document describes how to configure the Voyager™1202G reader and Hyperion 1300G reader
for barcode reading in Lectra applications. This reader has been validated with the following software:

• LeatherScan

• LeatherSupervisor

• LeatherManager

• GPDirectScan
This document is intended for Lectra training staff and technical personnel.

How to use this manual

This document gives the detailed procedure to configure the barcode reader before first use.

Please consider the environment before printing this document.

This scanner CANNOT read barcodes from an LCD monitor so you must print pages containing configuration barcodes.

July 2012 – 510166 AA lectra.com 3/7


VOYAGER™ 1202G BARCODE READER
HYPERION 1300G BARCODE READER
Installation and configuration

Contents
1. Installation and initialization ................................................................................................................... 5
2. RS-232 interface selection....................................................................................................................... 6
3. GPDirectScan Configuration ................................................................................................................... 6
4. Operating test ........................................................................................................................................... 7
4.1 Test with LeatherSupervisor (or LeatherScan) ................................................................................ 7
4.2 Test with GPDirectScan ................................................................................................................... 7

July 2012 – 510166 AA lectra.com 4/7


VOYAGER™ 1202G BARCODE READER
HYPERION 1300G BARCODE READER
Installation and configuration

1. INSTALLATION AND INITIALIZATION

To correctly install the barcode reader, follow these two steps in order.

1. Install the driver by launching the following script file :


a. For LeatherSupervisor installation :
[LeatherSupervisor installation folder]\Driver\Honeywell\_Install.bat
b. For LeatherScan installation :
[LeatherScan installation folder]\Driver\Honeywell\_Install.bat
c. For GPDirectScan installation:
[GPDirectScan installation folder]\Drivers\Honeywell\_Install.bat
2. Connect the Voyager™ cradle or the Hyperion reader to the host through the USB connector, using
the corresponding cable:

Voyager 1202G

Hyperion 1300G

July 2012 – 510166 AA lectra.com 5/7


VOYAGER™ 1202G BARCODE READER
HYPERION 1300G BARCODE READER
Installation and configuration

To reduce the barcode reader beep volume, scan the following barcode:

To increase the barcode reader beep volume, scan the following barcode:

2. RS-232 INTERFACE SELECTION


Scan the following barcode in order to emulate a RS232-based COM port and to be able to use Lectra
applications:

3. GPDIRECTSCAN CONFIGURATION
For GPDirectScan which requires the CR terminator, read the following barcode:

July 2012 – 510166 AA lectra.com 6/7


VOYAGER™ 1202G BARCODE READER
HYPERION 1300G BARCODE READER
Installation and configuration

4. OPERATING TEST

4.1 Test with LeatherSupervisor (or LeatherScan)

1. Launch LeatherSupervisor (or LeatherScan).

2. Click on the toolbar to open the Configuration dialog box.


3. Select the Barcodes tab.
4. Select the right COM port.
5. Read the test codes below in the Sample field.

4.2 Test with GPDirectScan

1 Launch GPDirectScan.
2 Open the Configuration dialog box.
3 Select the right COM port.
4 Read the test codes below in the Sample field.

The corresponding text should be displayed.

July 2012 – 510166 AA lectra.com 7/7