Beruflich Dokumente
Kultur Dokumente
G.Fernández
1 12/05/06 Para Diseño F. Anacona M.Pap
C. López
APROBADO POR FIRMA FECHA
DOC: REV.
GIC-0000-0
ET-0000-0-000-04-751 1
::ODMA\PCDOCS\TEC_GIC\596\1
CELULOSA ARAUCO Y CONSTITUCIÓN S.A. PROYECTOS GIC 2006-2007
ÍNDICE
1. ALCANCE...........................................................................................................................1
1.1. INTRODUCCIÓN........................................................................................................1
1.2. DESCRIPCIÓN...........................................................................................................1
1.3. RECOMENDACIONES ..............................................................................................1
1. ALCANCE
1.1. Introducción
Esta especificación es parte de los Proyectos GIC 2006-2007 de Celulosa Arauco. Esté documento
contiene Tabla de Selección de Válvulas y sus hojas de datos.
1.2. Descripción
La tabla de selección (Anexo 1), muestra las válvulas que pueden ser empleadas según el código del
fluido en la cañería. La válvulas se encuentran diferenciadas según fluido, tamaño, tipo y forma de
conexión.
Ejemplo: Si se requiere conocer qué válvulas de globo de 100 mm de diámetro pueden ser
empleadas en una línea de condensado de baja presión (C01) de acero inoxidable, entonces:
• Según el diámetro de la válvula, entrar a la Tabla de Selección (Anexo 1), con el
tipo de válvula. Diámetro 100 mm corresponde a tabla “DN 65 and UP”.
• Localizar el fluido que circula por la cañería donde se va a emplear la válvula.
• Ubicar la clase correcta de la tubería para dicho fluido.
• Localizar el número de válvula (Anexo 2) para el fluido que se seleccionó. Para
éste ejemplo, V-2236 y V-2267.
• Ver las hojas de datos de las válvulas seleccionadas y comprobar su existencia
según el diámetro buscado y tipo de conexión.
1.3. Recomendaciones
- Para vapor se prefiere utilizar válvulas butt weld o socket weld, en vez de con flanges o
roscadas.
ANEXO 1
12-05-2006
TEC_GIC-#599-v1-ET-0000-0-000-04-751__ANEXO_1 PAGINA 1 DE 4 Tabla_Selección
CELULOSA ARAUCO Y CONSTITUCIÓN S.A. TABLA DE SELECCIÓN
PROYECTOS GIC 2005 - 2006
V-9242A B FL V-4451A SW
Gas, Non-condensable Concentrated CNCG G50 150H2A
V-9242 B FL V-4451 SW
Gas, Non-condensable DNCG G51 0H2A
V-9231 B FL V-3135 B FL V-1131 FL V-4451 SW V-3222 THRE
Mill Air G75 150H1A
V-4121 THRE V-3451 SW
V-9231 B FL V-3135 B FL V-1131 FL V-4451 SW V-3222 THRE
Instrument Air G76 150H1A
V-9232 B FL V-3138 B FL V-4121 THRE V-3451 SW
V-4451 SW V-3222 THRE
Aluminium Sulphate Al2 (SO4)3 K02 150H2A
V-4121 THRE V-3451 SW
V-4233 FL V-3249 FL V-5140 FL
Chlorine Dioxide Solution ClO2 (6) K32 16S2A
V-6231 FL V-3250 FL
V-4242 FL V-3232 FL V-4451 SW V-3451 SW
Methanol K40 150H2A
V-6241 FL V-3230 B FL V-4121 THRE V-3222A SW
Caustic Soda ( 32 % ) K44 150H1A
V-4451 SW
V-6241 FL V-3230 B FL V-4121 THRE V-3222A SW
Caustic Soda ( 20 % ) K45 150H1A
V-4451 SW
V-3242 FL V-1245 FL V-4121 THRE V-3222 THRE
Sodium Bisulphite K48 150H2A
V-4451 SW V-3451 SW
V-2241 FL V-3242 FL V-1245 FL V-2221 THRE V-4121 THRE V-3222 THRE
Sodium Chlorate K62 150H2A
V-4451 SW V-3451 SW
V-2241 FL V-3242 FL V-1245 FL V-2221 THRE V-4121 THRE V-3222 THRE
Sodium Sulphate Solution, Alcaline K73 150H2A
V-4451 SW V-3451 SW
V-6241 FL V-3244 FL V-6241 FL V-3244 FL
Sulphur Dioxide (SO2); 100% liquid K86 150H2A
V-4121 THRE
V-2241 FL V-3242 FL V-1245 FL V-2221 THRE V-4121 THRE V-3222 THRE
SO2 Water to bleach plant ( 10 g/lt ) K87 150H2A
V-4451 SW V-3451 SW
V-4233A FL V-3141 FL V-5140 FL
Sulphuric Acid ( 98 % ) K90 150C1B
V-3142 FL
12-05-2006
TEC_GIC-#599-v1-ET-0000-0-000-04-751__ANEXO_1 PAGINA 2 DE 4 Tabla_Selección
CELULOSA ARAUCO Y CONSTITUCIÓN S.A. TABLA DE SELECCIÓN
PROYECTOS GIC 2005 - 2006
Black Liquor, Thick 69 % from evaporators to R.B. mix V-6418 FL V-1441 FL V-3421 THRE V-1421 THRE
L61 300H1A
tank V-3451 SW V-1451 SW
12-05-2006
TEC_GIC-#599-v1-ET-0000-0-000-04-751__ANEXO_1 PAGINA 3 DE 4 Tabla_Selección
CELULOSA ARAUCO Y CONSTITUCIÓN S.A. TABLA DE SELECCIÓN
PROYECTOS GIC 2005 - 2006
V-9232 B FL V-2132 FL V-3135 B FL V-1131 FL V-2221 THRE V-4121 THRE V-3222 THRE
Potable Water W10 150H1A
V-9232 B FL V-2132 FL V-3135 B FL V-1131 FL V-2221 THRE V-4121 THRE V-3222 THRE
Water, Sealing, Low Pressure W20 150H1A
V-4451 SW
V-2221 THRE V-4121 THRE V-3222 THRE
Seal Water HP W21 150H1A
V-4451 SW
V-3143 B FL V-1232 FL V-4215 THRE V-1219 THRE
Fire Water W23 150FW1
Fire Water - Hot dip Galvanized (Cooling Towers, internal V-3143 FL V-1232 FL V-4215 THRE V-1219 THRE
W23 150FW2
pipes)
V-9232 B FL V-2132 FL V-3135 B FL V-1131 FL V-2221 THRE V-4121 THRE V-3222 THRE
Cooling Water, return to cooling towers W24 150H1A
V-4451 SW
V-9232 B FL V-2132 FL V-3135 B FL V-1131 FL V-2221 THRE V-4121 THRE V-3222 THRE
Warm Water W30 150H1A
V-4451 SW
V-9232 B FL V-2132 FL V-3135 B FL V-1131 FL V-2221 THRE V-4121 THRE V-3222 THRE
Hot Water W35 150H1A
V-4451 SW
V-9232 B FL V-2241 FL V-3242 FL V-1245 FL V-2221 THRE V-4121 THRE V-3222 THRE
Demineralized Water W48 150H1A
V-4451 SW
V-9231 B FL V-3242 FL V-1132 FL V-4212 THRE V-3411 THRE V-1211 THRE
Demineralized & Deaerated Water W49 150C1B
V-9232 B FL V-3139 B FL
V-2766 BW V-3766 BW V-1766 BW V-2756 SW V-3756 SW V-1756 SW
Water Boiler Feed, High Pressure W53 1500C1B
V-2537 BW V-3536 FL V-1536 FL V-2556 SW V-3557 SW V-1556 SW
Attemperator Water, Medium Pressure W54 600C1B
V-2566 BW V-3567 BW V-1566 BW
V-3236 FL V-1236 FL V-4121 THRE
Water, Deionized W55 150H1A
V-4451 SW
NOTES:
Connections: SW: Socket Weld; BW: Buttweld; F: Flanged; TH: Threaded; B FL: Between Flanges
12-05-2006
TEC_GIC-#599-v1-ET-0000-0-000-04-751__ANEXO_1 PAGINA 4 DE 4 Tabla_Selección
CELULOSA ARAUCO Y CONSTITUCIÓN S.A. PROYECTOS GIC 2006-2007
ANEXO 2
Number Title
V-1131 Gate - Solid Wedge - Cast Iron - Bronze Trim
V-1132 Gate - Solid Wedge - Cast Iron - Bronze Trim
V-1142 Gate - Wafer, Knife - Cast or Fabricated 304SS, Metal to Metal Seat
V-1144 Gate - Wafer, Knife - Cast or Fabricated 316SS, Metal to Metal Seat
V-1211 Gate – Wedge - U-Bolt Clamp Type - All Iron
V-1219 Gate – Wedge - All Bronze, Underwriters Approved
V-1221 Gate – Wedge - All 316SS
V-1232 Gate – Wedge - Cast Iron/Bronze Trim, Underwriters Approved
V-1236 Gate – Wedge - Cast Carbon Steel, Half Stellite Trim
V-1245 Gate – Wedge - All 316 SS
V-1251 Gate – Wedge - All 316 SS
V-1266 Gate – Wedge - Cast Carbon Steel, Half Stellite Trim
V-1291 Gate - Wafer, Knife, Resilient Seat - Cast and Fabricated 316 SS
V-1421 Gate – Wedge - All 316 SS
V-1435 Gate – Wedge - Cast Carbon Steel, Full Stellite Trim
V-1436 Gate – Wedge - Cast Carbon Steel, Half Stellite Trim
V-1438 Gate – Wedge - Chrome Moly Steel Full Stellite Trim
V-1441 Gate – Wedge - All 316 SS
V-1451 Gate – Wedge - All 316 SS
V-1465 Gate – Wedge - Cast Carbon Steel, Full Stellite Trim
V-1466 Gate – Wedge - Cast Carbon Steel, Half Stellite Trim
V-1469 Gate – Wedge - Chrome Moly Steel, Full Stellite Trim
V-1516 Gate – Wedge - Forged Carbon Steel, Alloy Steel Trim
V-1536 Gate – Wedge - Cast Carbon Steel Half Stellite Trim
V-1538 Gate – Wedge - Chrome Moly Steel, Full Stellite Trim
V-1556 Gate – Wedge - Forged carbon Steel, Half Stellite Trim
V-1557 Gate – Wedge - Forged Carbon Steel, Full Stellite Trim
V-1558 Gate – Wedge - Chrome Moly Steel, Full Stellite Trim
V-1559 Gate – Wedge - All 316 SS
V-1566 Gate – Wedge - Cast Carbon Steel, Half Stellite Trim
PROJ. DATE OF
APPR. P.Healy ISSUE
PROJ. DATE OF
APPR. P.Healy ISSUE
PROJ. DATE OF
APPR. P.Healy ISSUE
PROJ. DATE OF
APPR. P.Healy ISSUE
SIZE 2 21 / 2 3 4 5 6 8 10 12 14 16 18 20 24 30 36
A 7 71 / 2 8 9 10 101/2 111/2 13 14 15 16 17 18 20 24 28
B 1615/16 177/8 21 253/8 293/8 321/2 411/8 525/16 60 1/4 689/16 751/2 841/4 945/8 114 142 163
C
7 8 9 10 12 12 16 18 18 21 22 24 26 32 36 42
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
All staff members are responsible for ensuring that they are using the correct revision of this document.
OWNER APPROVAL: DATE: DOC. NO.:
30Aug96 D3620004
F0163001 Rev.00/v1131 rev-0
VALVE STANDARD (Imperial)
TYPE: Gate - Solid Wedge VALVE. NO.: V-1132
Cast Iron - Bronze Trim
SERVICE: REV. NO.:
B 1615/1 177/8 21 253/8 293/8 321/2 411/8 525/16 601/4 689/16 751/2 841/4 945/8 114 142 163
C 7 8 9 10 12 12 16 18 18 21 22 24 26 32 36 42
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
All staff members are responsible for ensuring that they are using the correct revision of this document.
OWNER APPROVAL: DATE: DOC. NO.:
Sept. 04 D3620005
F0163001 Rev.00/v1132 rev-0
VALVE STANDARD (Imperial)
TYPE: Gate - Wafer, Knife VALVE. NO.: V-1142
Cast or Fabricated 304 SS, Metal to Metal Seat
SERVICE: REV. NO.:
o o
To 24” 150 psig at Ambient F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
B 163/8 181/8 203/4 283/4 331/2 41 453/4 531/8 591/2 671/2 723/8 841/2
C 10 10 10 14 14 18 18 20 20 24 24 30
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
.
OWNER APPROVAL: DATE: DOC. NO.:
Sept. 04 D3620008
F0163001 Rev.00/v1142 rev-0
VALVE STANDARD (Imperial)
TYPE: Gate - Wafer, Knife VALVE. NO.: V-1144
Cast or Fabricated 316 SS, Metal to Metal Seat
SERVICE: REV. NO.:
A 1⅞ 2 2 2¼ 2¾ 2¾ 3 3 3½ 3½ 4½ 4½
B 16⅜ 18⅛ 20¾ 28¾ 33½ 41 45¾ 53⅛ 59½ 67½ 72⅜ 84½
C 10 10 10 14 14 18 18 20 20 24 24 30
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
400 max psig at -20 to 150 F kPa(g) C
o o
325 psig at 300 F kPa(g) C
o o
250 psig at 450 F kPa(g) C
o o
200 psig at 550 max F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
C 3 3 31/2 4 41/2 5 6 7
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
175 max psig at Cold Water F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 71/2 8 10 12 12 14 16 18 20
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
B 161/4 171/8 20 231/4 40 48 56 67 751/2 831/4 863/4 945/8 1101/2 135 1501/4
C 8 8 10 10 14 18 20 20 24 26 27 30 30 36 42
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
B 8 81/4 87/8 11 17 171/2 181/2 223/4 301/4 373/4 481/4 573/4 65 75 845/16 93 107
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
275 psig at -20 to 100 F kPa(g) C
o o
240 psig at 200 F kPa(g) C
o o
215 psig at 300 F kPa(g) C
o o
195 psig at 400 F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
C 8 8 10 10 14 18 20 20 24 26 27 30 30 36 42
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
150 max psig at Ambient F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
B 163/8 181/8 203/4 283/4 331/2 41 453/4 531/8 591/2 671/2 723/8 841/2
C 10 10 10 14 14 18 18 20 20 24 24 30
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 4 4 5 5 7 8
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
All staff members are responsible for ensuring that they are using the correct revision of this document.
OWNER APPROVAL: DATE: DOC. NO.:
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
C 8 10 10 10 14 18 20 22 26 30 30 30 36 36
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 8 10 10 10 14 18 20 22 26 30 30 30 36 36
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 8 10 10 10 14 18 20 22 26 30 30 30 36 36
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particles inspection
(MP1) of exterior and accessible interior surfaces to ANSI B16.34
Annex C (C/W documentation)
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
C 5 5 6 10 10 10 10 12 16 18 22 22 24 30 30 30 36
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
A 3 31 / 2 4 41/2 5 53/4
C 4 4 5 5 7 8
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
C 7 81/2 10 10 10 14 18 20 22 26 30 30 30 36 36
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 7 81/2 10 10 10 14 18 20 22 26 30 30 30 36 36
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
Cast bodies and bonnets require magnetic particles inspection
(MP1) or exterior and accessible interior surfaces to ANSI B16.34
Annex C (C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 7 81/2 10 10 10 14 18 20 22 26 30 30 30 36 36
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
1. Cast bodies and bonnets require magnetic particles inspection
(MP1) or exterior and accessible interior surfaces to ANSI B16.34
Annex C (C/W documentation)
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
B 65/8 65/8 65/8 651/8 85/16 101/16 101/16 111/4 141/16 173/4 201/2
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 111/2 13 14 17 22 26 31 33 35 39 43 47 55 65 82
C 10 10 10 14 20 24 24 30 30 36 36 36 42 -- --
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle inspection (MPI)
of exterior and all accessible interior surfaces to ANSI B16.34
Annex C (C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
A 111/2 13 14 17 22 26 31 33 35 39 43 47 55
C 10 10 10 14 20 24 24 30 30 36 36 36 42
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle inspection (MPI)
of exterior and all accessible interior surfaces to ANSI B16.34
Annex C (C/W documentation).
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
C 4 4 4 4 43/4 6 6 7
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 111/2 13 14 17 22 26 31 33 35 39 43 47 55 65 82
C 10 10 12 14 22 24 26 30 36 36 36 36 42 34 34
Dimensions are composite and for approximate clearance only. For construction, use manufacture’s catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle inspection (MPI) of
exterior and al accessible interior surface to ANSI B16.34 Annex C
(C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
A 91/2 111/2 13 14 17 22 26 31 33 35 39 43 47 55
C 8 10 10 10 14 20 20 24 30 30 36 36 36 42
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle inspection (MPI) of
exterior and all accessible interior surface to ANSI B16.34 Annex C
(C/W documentation).
2. Cast bodies require radiographic testing (RT) of all critical areas to ANSI
B16.34 Annex B (C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
B 13 133/4 171/4 181/2 241/8 25 273/4 443/8 535/8 621/4 681/4 741/2 98 108 1231/4 98
C 5 5 8 8 14 14 14 26 30 36 36 48 48 48 60 60
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle inspection
(MPI) of exterior and all accessible interior surface to ANSI
B16.34 Annex C (C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
B 13 133/4 171/4 181/2 241/8 25 273/4 443/8 535/8 621/4 681/4 741/2 98 108 1231/4 98
C 5 5 8 8 14 14 14 26 30 36 36 48 48 48 60 60
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle inspection
(MPI) of exterior and all accessible interior surface to ANSI
B16.34 Annex C (C/W documentation).
C 8 8 9 11 14 16 21 23 26
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 3 1 /8 3 1 /8 3 5 /8 4 3 /8 5 6 6 3 /4 8 1 /4
C 3 3 4 4 4 5 1 /2 5 1 /2 6 3 /8
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 8 10 10 10 14 18 20 24 24 24 24
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 41/4 45/8 5 51/2 61/2 8 81/2 91/2 111/2 16 191/2 241/2 271/2
C 4 4 41/2 41/2 8 8 10 10 10 14 18 18 22
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
275 psig at -20 to 100 F kPa(g) C
o o
240 psig at 200 F kPa(g) C
o o
215 psig at 300 F kPa(g) C
o o
195 psig at 400 F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
C 8 10 10 10 14 18 20 24 24 24 24
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
C 8 -- 10 14 14 18 18
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 3 31 / 2 4 41/2 5 8 8 10 12 16 20 263/4
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
C 8 9 10 10 14 20 24 27 30 42
Dimensions are composite and for approximate clearance only. For construction, use manufacture’s catalogue or drawing.
NOTE:
Cast bodies and bonnets require magnetic particle inspection (MPI) of
exterior and accessible interior surfaces to ANSI B16.34 Annex C
(C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 8 9 10 10 14 20 24 27 30 42
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
Cast bodies and bonnets require magnetic particle inspection (MPI) of exterior
and accessible interior surfaces to ANSI B16.34 Annex C (C/W documentation).
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
C 8 8 -- 10 14 18 18
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
NOTE:
Cast bodies and bonnets require magnetic particle
inspection (MPI) of exterior and all accessible interior
surfaces to ANSI B16.34 Annex C (C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 8 9 10 10 14 20 24 27 30 42
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
1. Cast bodies and bonnets require magnetic particle inspection (MPI)
of exterior and accessible interior surfaces to ANSI B16.34 Annex C
(C/W documentation).
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 111/2 -- 14 17
B 201/2 -- 25 29
C 10 -- 14 18
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
NOTES:
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 4 4 4 4 6 8 8 8
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 91/2 111/2 13 14 17 22 26 31 33
C 8 10 12 14 18 24 24 275/8 34
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle inspection (MPI) of
exterior and all accessible interior surfaces to ANSI B16.34 Annex C
(C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
5
B 10 175/8 191/2 211/4 231/4 231/8 38 /8 47 49 53
C 6 8 10 12 14 18 24 24 30 34
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle inspection (MPI)
of exterior and accessible interiors surfaces to ANSI B16.34 Annex C
(C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
C 6 5 93/4 12 12 12
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle inspection (MPI)
of exterior and all accessible interior surfaces to ANSI B16.34
Annex C (C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle inspection (MPI)
of exterior and all accessible interior surfaces to ANSI B16.34
Annex C (C/W documentation).
END CONNECTION: For 125# Flanges - Flat Face SEALS: Buna ‘N’ - O-Ring
BONNET: -- PLUG: --
OPERATOR: -- BALL: --
STEM: -- DISC: Aluminum Bronze
BODY: Cast Iron ASTM A126 CL.B PACKING: --
SEAT: -- SPRING: 316 SS
SIZE 2 2 1/2 3 4 6 8 10 12 14 16 18 20 24 30 32 42 48 to 72
A 21/8 23/8 25/8 25/8 33/4 5 51/2 71/8 71/4 71/2 8 8 3/8 83/4 12 141/2 17 205/8
B 41/8 47/8 53/8 67/8 83/4 11 133/8 161/8 173/4 201/4 215/8 237/8 281/4 343/4 411/4 48 541/2
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
NOTE:
Size 2 - 12” 200 max PSIG at 150°F, 175 PSIG at 250 max °F
Size 14 - 24” 150 max PSIG at 150°F, 125 PSIG at 250 max °F
Size 30 - 48” 150 max PSIG at 150°F, 75 PSIG at 250 max °F
o o
See Note psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
END CONNECTION: For 125# Flanges - Flat Face SEALS: Buna ‘N’ O-ring
BONNET: -- PLUG: --
OPERATOR: -- BALL: --
STEM: -- DISC: 316 SS
BODY: Cast Iron ASTM A126 CL.B PACKING: --
SEAT: -- SPRING: 316 SS
SIZE 2 21/2 3 4 6 8 10 12 14 16 18 20 24 30 32 42 48 to 72
A 21/8 23/8 25/8 25/8 33/4 5 51/2 71/8 71/4 71/2 8 83/8 83/4 12 141/2 17 205/8
B 41/8 47/8 53/8 67/8 83/4 11 133/8 161/8 173/4 201/4 215/8 237/8 281/4 343/4 411/4 48 541/2
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
o o
Size 2 - 12” 200 max PSIG at 150 F Size 30 - 48” 150 max PSIG at 150 F
o o
175 PSIG at 250 max F 75 PSIG at 250 max F
o
Size14 - 24” 150 max PSIG at 150 F
o
125 PSIG at 250 max F
o o
See Note psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
END CONNECTION: For 125# Flanges - Flat Face SEALS: Buna ‘N’ O-ring
BONNET: -- PLUG: --
OPERATOR: -- BALL: --
STEM: -- DISC: Carbon Steel ASTM A216 WCB
BODY: Cast Iron ASTM A126 CL.B PACKING: --
SEAT: -- SPRING: 316 SS
SIZE 2 21/2 3 4 6 8 10 12 14 16 18 20 24 30 32 42 48 to 72
A 21/8 23/8 25/8 25/8 33/4 5 51/2 71/8 71/4 71/2 8 83/8 83/4 12 141/2 17 205/8
B 41/8 47/8 53/8 67/8 83/4 11 133/8 161/8 173/4 201/4 215/8 237/8 281/4 343/4 411/4 48 541/2
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
o o
Size 2 - 12” 200 max PSIG at 150 F Size 30 - 48” 150 max PSIG at 150 F
o o
175 PSIG at 250 max F 75 PSIG at 250 max F
o
Size 14 - 24” 150 max PSIG at 150 F
o
125 PSIG at 250 max F
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
NOTE:
Available with kynar or Teflon lining.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
NOTE:
Available with Kynar or teflon lining.
o o
See Note psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
END CONNECTION: For 125# Flanges - Flat Face SEALS: Buna ‘N’ O-ring
BONNET: -- PLUG: --
OPERATOR: -- BALL: --
STEM: -- DISC: Aluminum Bronze
BODY: Cast Iron ASTM A126 CL.B PACKING: --
SEAT: -- SPRING: 316 SS
SIZE 2 21/2 3 4 6 8 10 12 14 16 18 20 24 30 32 42 48 to 72
A 21/8 23/8 25/8 25/8 33/4 5 51/2 71/8 71/4 71/2 8 83/8 83/4 12 141/2 17 205/8
B 41/8 47/8 53/8 67/8 83/4 11 133/8 161/8 173/4 201/4 215/8 237/8 281/4 343/4 411/4 48 541/2
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
o o
Size 2 - 12” 200 max PSIG at 150 F Size 30 - 48” 150 max PSIG at 150 F
o o
175 PSIG at 250 max F 75 PSIG at 250 max F
o
Size 14 - 24” 150 max PSIG at 150 F
o
125 PSIG at 250 max F
UL & FM approved.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 3¼ 3¼ 3¾ 4⅜ 5 5½ 6¾ 8¼
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 3¼ 3¼ 3½ 3½ 5 5¼ 5¼ 6
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
A 23/8 25/8 27/8 27/8 37/8 5 53/4 71/8 71/4 71/2 8 85/8 83/4 13 151/4 17 205/8
B 41/8 47/8 53/8 67/8 83/5 11 133/8 161/8 173/4 201/4 215/8 237/8 281/4 343/4 411/4 48 541/2
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
275 max psig at -20 to 100 F kPa(g) C
o o
255 psig at 155 F kPa(g) C
o o
240 psig at 200 F kPa(g) C
o o
225 psig at 250 max F kPa(g) C
A 23/8 25/8 27/8 27/8 37/8 5 53/4 71/8 71/4 71/2 8 85/8 83/4 13 151/4 17 205/8
B 41/8 47/8 53/8 67/8 83/4 11 133/8 161/8 173/4 201/4 215/8 237/8 281/4 343/4 411/4 48 541/2
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
B 61/4 63/4 71/2 81/2 103/4 123/4 151/2 161/2 187/8 211/2 231/2 257/8 283/4
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 41/4 45/8 5 51/2 61/2 8 81/2 91/2 111/2 14 191/2 241/2 271/2 31 34 381/2 381/2 51
B 31/4 37/16 315/16 315/16 45/8 53 / 8 6 63/16 73/4 95/8 113/8 141/16 141/2 161/8 183/8 203/8 221/2 243/8
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
Saran 275 psig at 175 F kPa(g) C
o o
Polypropy. 275 psig at 225 F kPa(g) C
o o
Kynar 275 psig at 275 F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
Available linings:
Saran
Polypropylene }
All sizes
Kynar - all sizes except 22“ & 8”
Specify which
o o
Saran 275 psig at 175 F kPa(g) C
o o
Polypropy. 275 psig at 225 F kPa(g) C
o o
Kynar 275 psig at 275 F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
Available linings:
Saran
Polypropylene }
All sizes
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 8 81/2 91/2 111/2 14 191/2 241/2 271/2 31 34/36 36/381/2 381/2/40 48/51 55/60 68
B 61/4 63/4 71/2 85/8 103/4 123/4 151/2 161/2 187/8 211/2 231/2 257/8 283/4 38 42
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
B 31/2 37/8 41/2 5 65/16 611/16 75/16 71/8 811/16 105/8 125/8 143/8 161/8 18 197/8
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
1 11/2 2 21/2 3 4 6 8 10 12 14 16 18 20 24
A
3
C 311/16 63/8 71/4 81/4 83/4 91 / 4 12 135/8 161/2 18 203/4 231/8 245/8 277/8 31 /4
:
D
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
Cast bodies and bonnets require magnetic particle inspection (MPI)
of exterior and all accessible interior surfaces to ANSI B16.34
Annex C (C/W documentation).
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
B 311/16 63/8 71/4 81/4 83/4 93/4 12 135/8 161/2 18 203/4 231/8 245/8 277/8 313/4
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
NOTE:
Cast bodies and bonnets require magnetic particle inspection (MPI)
of exterior and all accessible interior surface to ANSI B16.34
Annex C (C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
B 311/16 63/8 71/4 81/4 83/4 93 / 4 12 135/8 161/2 18 203/4 231/8 245/8 277/8 313/4
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle inspection
(MPI) of exterior and all accessible interior surfaces to ANSI
B16.34 Annex C (C/W documentation).
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
B 311/16 63/8 71/4 81/4 83/4 93/4 12 135/8 161/2 18 203/4 237/8 245/8 277/8 313/4
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
NOTE:
Cast bodies and bonnets require magnetic particle inspection
(MPI) of exterior and all accessible interior surfaces to ANSI
B16.34 Annex C (C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
B 311/16 63/8 71/4 81/4 83/4 93 / 4 12 135/8 161/2 18 203/4 231/8 245/8 277/8 313/4
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
Cast bodies and bonnets require magnetic particle inspection
(MPI) of exterior and all accessible interior surfaces to ANSI
B16.34 Annex C (C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
B 311/16 63/8 71/4 81/4 83/4 93 / 4 12 135/8 161/2 18 203/4 231/8 245/8 277/8 313/4
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTE:
1. Cast bodies and bonnets require magnetic particle inspection
(MPI) of exterior and all accessible interior surfaces to ANSI
B16.34 Annex C (C/W documentation).
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 91/2 111/2 13 14 17 22 26 31 33 35 39 43 47 55
B 71/4 8 83/4 93/4 117/8 143/16 171/4 201/2 211/4 253/4 291/2 311/2 305/16 343/8
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
NOTES:
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
A 91/2 11/2 13 14 17 22 26 31 33 35 39 43 47 55
B 71/4 8 83/4 91/2 113/8 143/16 183/8 195/8 211/16 253/4 291/2 311/2 311/2 343/8
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
NOTES:
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
A 91/2 111/2 13 14 17 22 26 31 33 35 39 43 47 55
B 71/4 8 83/4 91/2 113/8 143/16 163/8 195/8 211/16 253/4 291/2 311/2 311/2 343/4
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle
inspection (MPI) of exterior and all accessible interior
surfaces to ANSI B16.34 Annex C (C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
A 4 4 4 5 6 73 / 4 73/4 9
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
A 4 4 4 5 6 73 / 4 73/4 9
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle
inspection (MPI) of exterior an all accessible interior
surfaces to ANSI B16.34 Annex C (C/W documentation).
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1. Cast bodies and bonnets require magnetic particle
inspection (MPI) of exterior an all accessible interior
surfaces to ANSI B16.34 Annex C (C/W documentation).
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
500 max psig at 100 F kPa(g) C
o o
300 psig at 250 F kPa(g) C
o o
100 psig at 350 F kPa(g) C
o o
0 psig at 380 max F kPa(g) C
27/16 2 /16
7
A 25/8 215/16 33/8 315/16 41/8 43/4 63/4
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
psig at 100 F kPa(g) C
o o
psig at 250 F kPa(g) C
o o
psig at 350 F kPa(g) C
o o
0 psig at 380 max F kPa(g) C
27/16 2 /16
7
A 25/8 215/16 33/8 315/16 41/8 43/4 63/4
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
0 psig at °F kPa(g) °C
psig at °F kPa(g) °C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
0 psig at °F kPa(g) °C
psig at °F kPa(g) °C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
B 31/2 39/16 43/8 45/8 47/8 43/4 71/4 715/16 113/16 121/2 - 181/2
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
15
B 39/16 33/4 43/8 43/4 415/16 75/16 715/16 113/16 131/2 15 /1 183/8
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
47/16 4 /16
7
C 5 5 531/4 6 7 8
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
47/16 4 /16
7
C 5 5 531/4 6 7 8
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at See Note Below F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
NOTES:
1 o o
/2 - 1” = 200 max psig at 120 F 4” = 150 max psig at 120 F
o o
148 psig at 225 max F 108 psig at 225 max F
o o
11/4 - 2” = 175 max psig at 120 F 6” = 126 max psig at 120 F
o o
132 psig at 225 max F 92 psig at 225 max F
o o
21/2 - 3” = 150 max psig at 120 F 8” = 100 max psig at 120 F
o o
114 psig at 225max F 78 psig at 225 max F
B 413/16 413/16 413/16 55/8 65/16 71/2 71/2 9 189/16 207/8 247/8 2815/16 3315/16
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
B 413/16 413/16 413/16 55/8 65/16 71/2 71/2 9 189/16 207/8 247/8 2815/16 3315/16 259/16
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
psig at °F kPa(g) °C
B 413/16 413/16 413/16 55/8 65/16 71/2 71/2 9 189/16 207/8 247/8 2815/16 3315/16 259/16
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
o o
psig at F kPa(g) C
A Available Sizes & Dimensions Vary With Manufacturer - Check Specific Catalogue
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
A Available Sizes & Dimensions Vary With Manufacturer - Check Specific Catalogue
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
A Available Sizes & Dimensions Vary With Manufacturer - Check Specific Catalogue
Dimensions are composite and for approximate clearance only. For construction, use manufacturer’s catalogue or drawing.
o o
275 max psig at 100 F kPa(g) C
o o
240 psig at 200 F kPa(g) C
o o
215 psig at 300 F kPa(g) C
o o
195 psig at 400 max F kPa(g) C
A Available Sizes & Dimensions Vary With Manufacturer - Check Specific Catalogue
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.
o o
275 max psig at 100 F kPa(g) C
o o
240 psig at 200 F kPa(g) C
o o
215 psig at 300 F kPa(g) C
o o
195 psig at 400 max F kPa(g) C
A Available Sizes & Dimensions Vary With Manufacturer - Check Specific Catalogue
Dimensions are composite and for approximate clearance only. For construction, use manufacturer's catalogue or drawing.