Service Mode
SMCS - 4490; 7451

Illustration 1 g00398567

GSC+ Display Area With The Service Mode Descriptions Of The Keypad

(1) Dedicated shutdown indicators

(2) Spare fault indicators

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 31/08/2010
Pesquisa de Mídia - RENR1200 - Electronic Modular Control Panel II+ (EMCP II+... Página 2 de 4

(3) Fault shutdown indicator

(4) Fault alarm indicator

(5) Upper display

(6) Lower display

(7) Keypad

Service mode is used for the following purposes.

 Assist with troubleshooting of diagnostic faults.

 Satisfy special applications.

 Satisfy customer needs.

 Verify generator set functions.

 Calibrate or adjust generator set functions.

Service Mode has ten options that can be selected. Service personnel use the options to obtain
information about the generator set, and the operator can program functions of the generator set.

Table 1

Service Mode Options


OP1 Fault log viewing
OP2-0 Engine/Generator setpoint viewing
OP2-1 Protective relaying setpoint viewing
OP2-2 AC factory calibration setpoint viewing
OP3 Password entry
OP4 Fault log clearing
OP5-0 Engine/Generator programming
OP5-1 Protective relaying programming
OP6 Spare Input/Output programming
OP7 Hourmeter programming (1)
OP8 Voltmeter/Ammeter programming
OP9 Engine setpoint verification
OP10 AC offset adjustment
(1) OP7 is not available for EUI engines.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 31/08/2010
Pesquisa de Mídia - RENR1200 - Electronic Modular Control Panel II+ (EMCP II+... Página 3 de 4

The keypad and the display of the GSC+ are used for activating service mode and selecting the
desired option. In service mode, the keys on the keypad have different functions, and the keys on the
keypad have different names. The preceding illustration shows the name of each key in service
mode. Also, there is a film (label) on the control panel door that identifies each key. The service
functions of the keys are listed below.

Scroll Right Key - This key is used in viewing information. This key scrolls right through the
information. When you are entering the password, this key represents the number 1.

Scroll Up Key - This key is used to scroll up information or this key is used to increase the value of
information. When you are entering the password this key represents the number 2.

Scroll Down Key - This key is used to scroll down through information or this key is used to
decrease the value of information. When you are entering the password, this key represents the
number 3.

ote: Scrolling rapidly through information requires holding down the scroll key.

Select Key - To view an option, use the Select key. To change an option, use the "Select" key. To
start the scrolling of information, use the "Select" key.

Enter Key - This key is used to enter information that has been changed into the GSC+ memory.

Exit Key - This key is used to exit service mode. The display now returns to normal mode. The
"SERV" indicator on the upper display is NOT SHOWING when the GSC+ is NOT in service mode.

Service Mode Key - This key is used to enter service mode. The "SERV" indicator on the upper
display FLASHES when the GSC+ is in service mode. The "SERV" indicator on the upper display
FLASHES when the keypad performs service mode functions.

Procedure To Enter Service Mode


ote: Any active shutdown fault must be made inactive in order to access service mode. A
FLASHING shutdown indicator means that a shutdown fault exists. To temporarily change a
shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the
OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an
inactive shutdown fault, the fault must not be occurring. Also, the ECS must be turned to the
OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, then
the GSC+ will not power up in OFF/RESET and any active shutdown fault must be corrected before
entering service mode.

ote: Service mode cannot be entered when the engine control switch (ECS) is in the AUTO
position.

1. Press the "SERVICE MODE" key on the keypad of the GSC+. The "SERV" indicator on the
upper display FLASHES whenever the GSC+ is in service mode.

2. The desired option (OP1 through OP10) can now be selected. Each option is described in the
topics that follow.

3. To return to normal mode, press the "EXIT" key a few times until the "SERV" indicator is not
showing.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 31/08/2010
Pesquisa de Mídia - RENR1200 - Electronic Modular Control Panel II+ (EMCP II+... Página 4 de 4

ote: To enter service mode options OP4 through OP8, the engine must be shut down. Turn the ECS
to the STOP position.

Service mode options OP4 through OP10 are password protected. Password protection reduces the
possibility of changing information by mistake. The password entry option (OP3) must be entered
correctly before access is gained to OP4 through OP10. See System Operation, "Password Entry
OP3". Options OP1 and OP2 are not password protected.