Sie sind auf Seite 1von 1

ULTIMATE ALLOWABLE

LIVE LOAD DUE TO


PARAPET KICKER
SUPPORT=64 kN/m TYP. ROOF STL POST
SDL= 20kN
LL= 20kN
WIND= 124kN
M= 70 kNm
* 77 Kn/m MA
MAX X*
n/m
80 K

MECHANICAL *

MECHANICAL STORAGE
72 K

BASEMENT
n/m
MAX
*

81 K
n/m
MAX
*
*
MAX
n/m
80 K
83 Kn/m MAX*
1500 MAX

*ULTIMATE ALLOWABLE LINE


LOAD DUE TO PARAPET
SUPPORT ALONG THIS SLAB
LOAD MAP SDL (kN/m2) Live (kN/m2)
EDGE
Parking- Basement 4 0.31 1.92
Parking- Typ 0.50 1.92
Parking- Loading Dock 0.50 12.0
Lobby/Corridor Residential 3.41 4.79
Lobby- Office 3.02 4.79 A-107
Lobby- Basement 2.66 4.79
Lobby- Ground Floor 8.73 4.79
Lobby / Corridor / Bridge 10.12 4.79
Ground Level Plaza (Planter) 16.7(UNO) 12.0 (UNO)
Ground Level Plaza no tree 7.40 12.0
Retail 3.50 4.79
Residential* 3.66 1.92
Bathroom 6.10 1.92
Exterior Residential Balcony 2.50 2.87
Mechanical / Heavy 1.59 10.0
Mechanical Space / Storage-Basement 0.72 5.99
Terrace 2.50 4.79 † SDL in model includes additional concrete curb weight of 3.54 kN/m2.
Green Roof 8.20 4.79
Roof 1.44 0.96 * An average SDL equal to 4.026 kN/m2 was used in ETABS as an average for Parcel 209 Job No. 025263
Egress 2.87 4.79 residential & bathroom SDL.
Office 4.12 3.83
Loading Diagrams August 2009
*Mecahnical Floor in model includes 1.44 kN/m2 to account for additional loads
Cladding - Typ (kN/m) 11.6 - from mechanical roof screen. LEVEL 7
3-30

Das könnte Ihnen auch gefallen