Beruflich Dokumente
Kultur Dokumente
Variants
Lists of variants - on request 79
Further productdocumentation
WinCAPS 80
WebCAPS 81
2
Product data CR, CRI, CRN, CRE, CRIE, CRNE
This data booklet deals with CR, CRI and CRN as well
as CRE, CRIE and CRNE pumps.
3
Product data CR, CRI, CRN, CRE, CRIE, CRNE
H
[m] 60 Hz
400
300
200
100
80
CR 1s CR 3 CR 10 CR 20 CR 45 CR 90
60 CRI 1s CRI 3 CRI 10 CRI CRN 45 CRN 90
CRN 1s CRN 3 CRN 10 20
CR 1 CR 5 CR 15 CRN CR 32 CR 64
40 CRI 1 CRI 5 CRI 15 20 CRN 32 CRN 64
CRN 1 CRN 5 CRN 15
30
20
0.8
1 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 Q [m³/h]
Eta
[%]
80
60
40
20
200
100
80
30
CRE 90
CRNE 90
20
TM02 7357 3605
0.8
1 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 200
Q [m³/h]
4
Product data CR, CRI, CRN, CRE, CRIE, CRNE
Applications
Application CR, CRI CRN CRE, CRNE
Water supply
Filtration and transfer at waterworks z z
Distribution from waterworks z z
Pressure boosting in mains z z
Pressure boosting in high-rise buildings, hotels, etc. z z
Pressure boosting for industrial water supply z z
Industry
Pressure boosting in...
process water systems z z z
washing and cleaning systems z z
vehicle washing tunnels z z
fire fighting systems z
Liquid transfer in...
cooling and air-conditioning systems (refrigerants) z z
boiler feed and condensate systems z z
machine tools (cooling lubricants) z z z
aquafarming z
Transfer of...
oils and alcohols z z
acids and alkalis z z
glycol and coolants z
Water treatment
Ultra-filtration systems z
Reverse osmosis systems z
Softening, ionising, demineralizing systems z
Distillation systems z
Separators z z z
Swimming baths z
Irrigation
Field irrigation (flooding) z
Sprinkler irrigation z z
Drip-feed irrigation z
z Recommended version.
Alternative version.
CRT, CRTE version available. For further information about CRT, CRTE pumps see, "Pumped liquids" page 68 or related CRT, CRTE data booklet.
5
Product data CR, CRI, CRN, CRE, CRIE, CRNE
Product range
CR, CR, CR, CR, CR, CR, CR, CR, CR, CR,
Range CR 1s
CRE 1 CRE 3 CRE 5 CRE 10 CRE 15 CRE 20 CRE 32 CRE 45 CRE 64 CRE 90
Nominal flow rate [m3/h] 1 1.2 3.6 6 12 18 24 38 54 77 108
Temperature range [°C] –20 to +120 –30 to +120
Temperature range [°C] – on request –40 to +180 –40 to +180
Max. pump efficiency [%] 35 49 59 67 70 72 72 76 78 79 80
CR pumps
Flow range [m3/h] 0.4-1.3 0.8-2.9 1.4-5.4 3-10.2 6-16 10-29 13-35 18-48 26-70 36-102 54-146
Max. pressure [bar] 22 24 24 23 26 24 21 27 26 18.2 16.5
High pressure [bar] – on request - 48 42 48 47 47 47 40 40 36 33
2.2-
Motor power [kW] 0.37-1.1 0.37-3.0 0.37-4.0 0.55-7.5 0.75-11 1.5-18.5 2.2-30 5.5-45 7.5-45 11-45
18.5
CRE pumps
Flow range [m3/h] - 0.8-2.9 1.4-5.4 3-10.2 6-16 10-29 13-35 18-48 26-70 36-102 54-146
Max. pressure [bar] - 24 24 23 26 24 21 27 26 18.2 16.5
2.2-
Motor power [kW] - 0.37-3.0 0.37-4.0 0.55-7.5 0.75-11 1.5-18.5 2.2-22 5.5-22 7.5-22 11-22
18.5
Version
CR, CRE:
Cast iron and z z z z z z z z z z z
stainless steel EN 1.4301/AISI 304
CRI, CRIE:
z z z z z z z - - - -
Stainless steel EN 1.4301/AISI 304
CRN, CRNE:
z z z z z z z z z z z
Stainless steel EN 1.4401/AISI 316
CRT, CRTE:
See the CRT, CRTE data booklet
Titanium
CR, CRE pipe connection
Oval flange (BSP) Rp 1 Rp 1 Rp 1 Rp 1¼ Rp 1½ Rp 2 Rp 2 - - - -
Rp 1¼
Oval flange (BSP) – on request Rp 1¼ Rp 1¼ Rp 1¼ Rp 1 Rp 2½ Rp 2½ - - - -
Rp 2
DN 25/ DN 25/ DN 25/ DN 25/
Flange DN 40 DN 50 DN 50 DN 65 DN 80 DN 100 DN 100
DN 32 DN 32 DN 32 DN 32
Flange – on request - - - - DN 50 - - DN 80 DN 100 DN 125 DN 125
CRI, CRIE pipe connection
Oval flange (BSP) Rp 1 Rp 1 Rp 1¼ Rp 1¼ Rp 1½ Rp 2 Rp 2 - - - -
Oval flange (BSP) – on request Rp 1¼ Rp 1¼ Rp 1 Rp 1 Rp 2 - - - - - -
DN 25/ DN 25/ DN 25/ DN 25/
Flange DN 40 DN 50 DN 50 - - - -
DN 32 DN 32 DN 32 DN 32
Flange – on request - - - - DN 50 - - - - - -
R 1¼ R 1¼ R 1¼ R 1¼ R2 R2 R2
PJE coupling (Victaulic) - - - -
DN 32 DN 32 DN 32 DN 32 DN 50 DN 50 DN 50
Clamp coupling (L-coupling) ø48.3 ø48.3 ø48.3 ø48.3 ø60.3 ø60.3 ø60.3 - - - -
Union (+GF+) G2 G2 G2 G2 G 2¾ G 2¾ G 2¾ - - - -
CRN(E) pipe connection
Oval flange (BSP) Rp 1 Rp 1 Rp 1¼ Rp 1¼ Rp 1½ Rp 2 Rp 2 - - - -
Oval flange (BSP) – on request Rp 1¼ Rp 1¼ Rp 1 Rp 1 Rp 2 - - - - - -
DN 25/ DN 25/ DN 25/ DN 25/
Flange DN 40 DN 50 DN 50 DN 65 DN 80 DN 100 DN 100
DN 32 DN 32 DN 32 DN 32
Flange – on request - - - - DN 50 - - DN 80 DN 100 DN 125 DN 125
R 1¼ R 1¼ R 1¼ R 1¼ R2 R2 R2
PJE coupling (Victaulic)
DN 32 DN 32 DN 32 DN 32 DN 50 DN 50 DN 50 R 3 1) R 4 1) R 4 1) R 5 1)
Clamp coupling (L-coupling) ø48.3 ø48.3 ø48.3 ø48.3 ø60.3 ø60.3 ø60.3 - - - -
Union (+GF+) G2 G2 G2 G2 G 2¾ G 2¾ G 2¾ - - - -
1) On request
6
Product data CR, CRI, CRN, CRE, CRIE, CRNE
The CR and CRE pumps are a non-self-priming, verti- CR, CRI, CRN pumps
cal multistage centrifugal pumps. The pumps are avail- MG motor
able with a Grundfos standard motor (CR pumps) or a Mounting designation
Up to 4 kW: V 18
From 5.5 kW: V 1
frequency-controlled motor (CRE pumps).
Insulation class F
The pump consists of a base and a pump head. The EFF 1
Efficiency class
chamber stack and the outer sleeve are secured (0.37-0.75 kW and 3 kW are EFF 2)
Enclosure class IP 55
between the pump head and the base by means of
P2: 0.37 - 1.1 kW:
staybolts. The base has suction and discharge ports on 3 x 220-255/380-440 V
Supply voltage
the same level (in-line). (Tolerance: +/–10%)
P2: 1.5-45 kW:
All pumps are equipped with a maintenance-free 3 x 220-277/380-480 V
Motor
CRE, CRIE, CRNE pumps
MGE motor MGE motor
( P2 ≤ 7.5 kW) ( P2 ≥ 11-22 kW)
Up to 4 kW: V 18
Mounting designation
Coupling From 5.5 kW: V 1
Insulation class F
Efficiency class EFF 1 EFF 2
Pump head
Enclosure class IP 54
P2: 0.37 - 1.1 kW:
1 x 200-240 V
Supply voltage P2: 11-22 kW:
(Tolerance: +/–10%) 3 x 380-415 V
Outer sleeve P2: 0.75 -7.5 kW:
Impellers 3 x 380-480 V
Supply frequency 50/60 Hz
Staybolt Single-phase MGE motors are EFF 2.
Base
Optional motors
GR5357 - GR3395
7
Product data CR, CRI, CRN, CRE, CRIE, CRNE
Viscosity
The pumping of liquids with densities or kinematic vis-
Position
Stellung 66 Position
Stellung 9
9 Position
Stellung 1212 Position
Stellung 33
Standard cosities higher than those of water will cause a consid-
erable pressure drop, a drop in the hydraulic
performance and a rise in the power consumption.
Fig. 4 Terminal box positions
In such situations the pump should be equipped with a
larger motor. If in doubt, contact Grundfos.
8
Control of E-pumps CR, CRI, CRN, CRE, CRIE, CRNE
CRE, CRIE and CRNE pumps are the ideal solution in • Steam boiler systems,
a number of applications characterized by a need for • Condensate systems,
variable flow at constant pressure. The pumps are • Sprinkler irrigation systems,
suited for water supply systems and pressure boosting, • Chemical industry, etc.
but also industrial applications.
Example: In a steam boiler, it is important to be able to
Depending on the nature of the application, the pumps monitor and control pump operation to maintain a con-
offer energy-savings, increased comfort and improved stant level of water in the boiler.
processing.
By using an E-pump with level sensor in the boiler, it is
E-pumps in the service of industry possible to maintain a constant water level.
Industry uses a large number of pumps in many differ- A constant water level ensures optimum and cost-effi-
ent applications. Demands on pumps in terms of pump cient operation as a result of a stable steam production.
performance and mode of operation make speed con-
Dosing applications
trol a must in many applications.
• Chemical industry (i.e. control of pH-values),
Below is mentioned some of the applications in which
• Petrochemical industry,
E-pumps are often used.
• Paint industry,
Constant pressure • Degreasing systems,
• Water supply, • Bleaching systems, etc.
• Washing and cleaning systems, Example: In the petrochemical industry, E-pumps with
• Distribution from waterworks, pressure sensor are used as dosing pumps. The E-
• Humidifying systems, pumps helps to ensure that the correct mixture ratio is
achieved when more liquids are combined.
• Water treatment systems,
• Process boosting systems, etc. E-pumps functioning as dosing pumps improves
Example: Within industrial water supply, E-pumps with processing and offer energy-savings.
integrated pressure sensor are used to ensure a con- E-pumps in commercial building services
stant pressure in the piping network. From the sensor,
Commercial building services use E-pumps to maintain
the E-pump receives inputs about changes of pressure
a constant pressure or a constant temperature based
as a result of changes in the consumption. The E-pump
on a variable flow.
responds to the input by adjusting the speed until the
pressure is equalized. The constant pressure is stabi- Constant pressure
lized once more on the basis of a preset setpoint.
• Water supply in high-rise buildings i.e. office build-
Constant temperature ings, hotels, etc.
• Air-conditioning systems at industrial plants, Example: E-pumps with pressure sensor are used for
water supply in high-rise buildings to ensure a constant
• Industrial cooling systems,
pressure even at the highest draw-off point. As the con-
• Industrial freezing systems, sumption pattern and thus the pressure changes during
• Casting and moulding tools, etc. the day, the E-pump continuously adapts its perform-
Example: In industrial freezing systems, E-pumps with ance until the pressure is equalized.
temperature sensor increase comfort and lower operat-
Constant temperature
ing costs compared with pumps without a temperature
sensor. • Air-conditioning systems in hotels, schools,
An E-pump continuously adapts its performance to the • Building cooling systems, etc.
changing demands reflected in the differences in tem- Example: E-pumps are an excellent solution in build-
perature of the liquid circulating in the freezing system. ings where constant temperature is essential. E-pumps
Thus, the lower the demand for cooling, the smaller the keep the temperature constant in air-conditioned high-
quantity of liquid circulated in the system and vice rise glass buildings, irrespective of the seasonal fluctu-
versa. ations of the out-door temperature, and various heat
impacts inside the building.
9
Control of E-pumps CR, CRI, CRN, CRE, CRIE, CRNE
Central
Control panel
management The control panel of the E-pump terminal box makes it
system
possible to change the setpoint settings manually.
Light fields
LON connection
LON
Interface
eg. G10 or G100
Indicator lights
GENIbus connection
TM02 6592 1404
E-pump
10
Control of E-pumps CR, CRI, CRN, CRE, CRIE, CRNE
Max.
Min.
Hset
TM00 9322 4796
11
Construction CR, CRI, CRN, CRE, CRIE, CRNE
1
1
3 3
10
2 10
4 6
7 4
5
5 6
7
9
9
TM02 1194 1403
8 11
12
Construction CR, CRI, CRN, CRE, CRIE, CRNE
2 2
3 3
10 10
4 1 4 1
6 5 6 5
11 9 11 9
7 7
8 8
TM01 1836 1403
13
13
Construction CR, CRI, CRN, CRE, CRIE, CRNE
14
Operating and inlet CR, CRI, CRN, CRE, CRIE, CRNE
pressure
ating pressure, pump type, type of shaft seal and liquid O-ring (cartridge) (balanced
HQQE –40°C to +120°C
seal), SiC/SiC, EPDM
temperature. The following curves apply to clean water O-ring (cartridge) (balanced
HQQV –20°C to +90°C
and water with anti-freeze liquids. For selecting the seal), SiC/SiC, FKM
right shaft seal, see ’List of pumped liquids’ page 68.
In case of extreme temperatures, i.e.
p [bar] • low temperatures down to –40°C or
35
30 • high temperatures up to +180°C,
25
H H see "List of variants - on request" on page 79.
20 Q Q
HQQE
TM03 2107 3705
15 Q Q
E HQQV E
10
5
0
-60 -40 -20 0 20 40 60 80 100 120 140
t [°C]
15
Operating and inlet CR, CRI, CRN, CRE, CRIE, CRNE
pressure
Maximum inlet pressure Examples of operating and inlet pressures
The values for operating and inlet pressures shown in
The following table shows the maximum permissible
the table must not be considered individually but must
inlet pressure. However, the current inlet pressure + the
always be compared, see the following examples:
pressure against a closed valve must always be lower
than the maximum permissible operating pressure. Example 1:
If the maximum permissible operating pressure is The following pump type has been selected:
exceeded, the conical bearing in the motor may be CR 3-10 A-A-A
damaged and the life of the shaft seal reduced. Max. operating pressure: 16 bar
CR, CRI, CRN 1s Max. inlet pressure: 10 bar
1s-2 ➝ 1s-27 10 [bar]
Discharge pressure against a closed valve: 9.6 bar, see
CR(E), CRI(E), CRN(E) 1
page 31.
1-2 ➝ 1-25 10 [bar]
1-27 15 [bar]
This pump is not allowed to start at an inlet pressure of
CR(E), CRI(E), CRN(E) 3
10 bar, but at an inlet pressure of 16.0 – 9.6 = 6.4 bar.
3-2 ➝ 3-15 10 [bar]
3-17 ➝ 3-25 15 [bar]
Example 2:
CR(E), CRI(E), CRN(E) 5
5-2 ➝ 5-9 10 [bar]
The following pump type has been selected:
5-10 ➝ 5-24 15 [bar] CR 10-2 A-A-A
CR(E), CRI(E), CRN(E) 10
Max. operating pressure: 16 bar
10-1 ➝ 10-5 8 [bar]
10-6 ➝ 10-17 10 [bar] Max. inlet pressure: 8.0 bar
CR(E), CRI(E), CRN(E) 15
Discharge pressure against a closed valve: 2.9 bar, see
15-1 ➝ 15-2 8 [bar]
15-3 ➝ 15-12 10 [bar] page 39.
CR(E), CRI(E), CRN(E) 20
This pump is allowed to start at an inlet pressure of 8.0
20-1 8 [bar]
20-2 ➝ 20-10 10 [bar] bar, as the discharge pressure against a closed valve is
CR(E), CRN(E) 32 only 2.9 bar, which results in an operating pressure of
32-1-1 ➝ 32-2 4 [bar] 8.0 + 2.9 = 10.9 bar. On the contrary, the max. operat-
32-3-2 ➝ 32-6 10 [bar] ing pressure of this pump is limited to 16 bar, as a
32-7-2 ➝ 32-10-2 15 [bar]
CR(E), CRN(E) 45
higher operating pressure will require an inlet pressure
45-1-1 ➝ 45-1 4 [bar] of more than 8.0 bar.
45-2-2 ➝ 45-3 10 [bar]
45-4-2 ➝ 45-7 15 [bar] In case the inlet or operating pressure exceeds the
CR(E), CRN(E) 64 pressure permitted, see "Lists of variants - on request"
64-1-1 4 [bar] page 79.
64-1 ➝ 64-2-1 10 [bar]
64-2 ➝ 64-5-2 15 [bar]
CR(E), CRN(E) 90
90-1-1 ➝ 90-2-2 10 [bar]
90-2-1 ➝ 90-4-2 15 [bar]
16
Selection and sizing CR, CRI, CRN, CRE, CRIE, CRNE
p H -3
0.8 80
[MPa] [m] -3-2
280
CRN, CRNE 32
-10-2 60
60 Hz -2 (E)
-2-1 (E)
260 ISO 9906 Annex A -2-2
-9 0.4 40
2.4
240
-9-2
-1 (E)
-1-1 (E)
Best
20
220
-8
-8-2
efficiency
0.0 0
2.0 0 4 8 12 16 20 24 28 32 36 40 44
200 -7 (E) Q [m³/h]
-7-2
180
0 2 4 6 8 10 12 Q [l/s]
-6 (E) P2 Eta
1.6 160 -6-2 [kW] [%]
3.2 P2 1/1 80
140 -5
2.4 Eta 60
-5-2 (E) P2 2/3
1.2 120 1.6 40
-4
-4-2 (E) 0.8 20
100
-3 0.0 0
0.8 80
-3-2 0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h]
H NPSH
60 -2 (E) [m] [m]
-2-1 (E)
0.0 0 8 4
0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h] 0 0
0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h]
0 2 4 6 8 10 12 Q [l/s]
P2 Eta
[kW] [%]
3.2 P2 1/1 80
2.4 Eta 60
P2 2/3
1.6 40
H
[m]
0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h]
NPSH
[m]
As the pump is sized on the basis of the highest possi-
TM02 7323 3103
32
24
QH 3500 rpm 1/1 16
12
ble flow, it is important always to have the duty point to
QH 3500 rpm 2/3 NPSH
16
8
8
4
the right on the efficiency curve (eta) in order to keep
0
0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h]
0
efficiency high when the flow drops.
Eta
Fig. 15 Example of a curve chart
TM00 9190 1303
2. Dimensional data
When sizing a pump the following must be taken into
account:
• Required flow and pressure at the draw-off point.
Q [ m3 /h ]
• Pressure loss as a result of height differences Fig. 17 Best efficiency
(Hgeo).
• Friction loss in the pipework (Hf).
It may be necessary to account for pressure loss in
connection with long pipes, bends or valves, etc.
Hf
• Best efficiency at the estimated duty point. Required flow,
required pressure
• NPSH value.
For calculation of the NPSH value, see "Minimum
inlet pressure - NPSH", page 20.
Hgeo
TM02 6711 1403
NPSH
17
Selection and sizing CR, CRI, CRN, CRE, CRIE, CRNE
H
[m] Q
P Qx Qn
Max. curve
Pn
nn Pn ⎛ n n⎞ 3
------ = ⎜ ------⎟
Px ⎝ n x⎠
Px nx
0
0 Q [m³/h] Fig. 20 Affinity equations
Legend
Fig. 19 Min. and max. performance curves
Hn Rated head in metres
In situations where it is not possible to select a duty
Hx Current head in metres
point close to the 100% curve the below affinity equa-
Qn Rated flow in m3/h
tions can be used. The head (H), the flow (Q) and the
input power (P) are all the appropriate variables for the Qx Current flow in m3/h
motor speed (n). nn Rated motor speed in min-1 (nn = 3500 min-1)
nx Current motor speed in min-1
Note:
ηn Rated efficiency in %
The approximated formulas apply on condition that the system
characteristic remains unchanged for nn and nx and that it is ηx Current efficiency in %
based on the formula H = k x Q2, where k is a constant.
WinCAPS and WebCAPS
The power equation implies that the pump efficiency is
unchanged at the two speeds. In practice this is not quite cor-
WinCAPS and WebCAPS are both selection pro-
rect. grammes offered by Grundfos.
Finally, it is worth noting that the efficiencies of the frequency The two programmes make it possible to calculate an
converter and the motor must be taken into account if a pre- E-pump’s specific duty point and energy consumption.
cise calculation of the power saving resulting from a reduction
of the pump speed is wanted. By entering the dimensional data of the pump, Win-
CAPS and WebCAPS can calculate the exact duty point
and energy comsumption.
For further information see page 80 and page 81.
18
Selection and sizing CR, CRI, CRN, CRE, CRIE, CRNE
3. Pump material
The material variant (CR(E), CRI(E), CRN(E)) should
be selected based of the liquid to be pumped. The prod-
uct range covers the following three basic types.
• The CR(E), CRI(E) pump types are suitable for
clean, non-aggressive liquids such as potable water,
oils, etc.
19
Selection and sizing CR, CRI, CRN, CRE, CRIE, CRNE
160 62
• water is drawn from depths,
150 45
• water is drawn through long pipes, 40
140 35
• inlet conditions are poor. H 30
Pb NPSH 130
25
To avoid cavitation, make sure that there is a minimum 120 20
pressure on the suction side of the pump. The maxi- 15
110
mum suction lift "H" in metres head can be calculated Hv 12
100 10
as follows: 8,0
90
6,0
H = pb x 10.2 – NPSH – Hf – Hv – Hs 80 5,0
4,0
pb = Barometric pressure in bar. 70 3,0
20
Selection and sizing CR, CRI, CRN, CRE, CRIE, CRNE
-3
0.8 80
-3-2
60 -2 (E)
-2-1 (E)
The power curves indicate -2-2
0.4 40 The eta curve shows the efficiency
pump input power per stage. -1 (E) of the pump. The eta curve is an
Curves are shown for com- 20 -1-1 (E)
average curve of all the pump
plete (1/1) and for reduced-di-
0.0 0 types shown in the chart.
ameter (2/3) impellers. 0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h] The efficiency of pumps with re-
duced-diameter impellers is ap-
0 2 4 6 8 10 12
P2
Q [l/s]
Eta prox. 2% lower than the eta curve
[kW] [%] shown in the chart.
3.2 P2 1/1 80
2.4 Eta 60
P2 2/3
1.6 40
0.8 20
0.0 0
0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h]
H NPSH
[m] [m] The NPSH curve is an average
32 QH 3500 rpm 1/1 16 curve for all the variants shown.
24 12 When sizing the pumps, add a
16
QH 3500 rpm 2/3 NPSH
8
safety margin of at least 0.5 m.
8 4
QH curve for each individual impeller. Curves for complete (1/1) and reduced-diameter (2/3) impellers are shown.
10
5. Due to the risk of overheating, the pumps should
not be used at a flow below the minimum flow rate. 0
40 60 80 100 120 140 160 180 t [°C]
6. The QH curves apply to a rated motor speed of
3500 min-1. All curves are based on current motor
speeds. Fig. 27 Minimum flow rate
21
Performance curves CR 1s
Technical data
CR 1s
p H
[kPa] [m]
CR 1s
240
-27 60 Hz
ISO 9906 Annex A
220
-25
2000
200 -23
180
-21
1600 -19
160
140 -17
-15
1200 120
-13
-12
100
-11
-10
800 80
-9
-8
60 -7
-6
400 40 -5
-4
-3
20 -2
0 0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Q [m³/h]
60 6 6
40 4 4
NPSH
20 2 2
TM02 7422 3605
0 0 0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Q [m³/h]
22
Technical data CR 1s
Dimensional sketch
D2
D1
B2
G 1/2 G 1/2
FGJ (DIN-ANSI-JIS)
A (Oval)
B1
PN 25 / DN 25/32
G 1/2 19 x 24.5
G 1/2 Rp 1
22 M10 x 40
ø100
ø140
ø89
75
50
CRI, CRN 1s
23
Performance curves CRI, CRN 1s
p H
[kPa] [m]
CRI, CRN 1s
240
-27 60 Hz
ISO 9906 Annex A
220
-25
2000
200 -23
180
-21
1600 -19
160
140 -17
-15
1200 120
-13
-12
100
-11
-10
800 80
-9
-8
60 -7
-6
400 40 -5
-4
-3
20 -2
0 0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Q [m³/h]
60 6 6
40 4 4
NPSH
TM02 7423 3605
20 2 2
0 0 0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Q [m³/h]
24
Technical data CRI, CRN 1s
Dimensional sketch
D2
D1
B2
G 1/2
G 1/2
FGJ (DIN-ANSI-JIS)
B1
ø14 19 x 27
G 1/2 4 x ø13
ø105
ø140
ø89
50
ø42.2
250
22
22
34
CR, CRE 1
25
Performance curves CR, CRE 1
p H
[kPa] [m]
-27 (E)
CR, CRE 1
240
60 Hz
-25 (E) ISO 9906 Annex A
220
2000 -23
200
-21
180
-19
1600
160
-17 (E)
140
-15
1200 120
-13 (E)
-12
100 -11
-10
800 80 -9 (E)
-8
60 -7
-6 (E)
-5
400 40
-4 (E)
-3
20 -2
0 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Q [m³/h]
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Q [l/s]
P2 Eta
[kW] [%]
0.10 50
Eta
0.08 P2 40
0.06 30
0.04 20
0.02 10
0.00 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Q [m³/h]
H NPSH
[m] [m]
10 5
QH 3500 rpm
8 4
6 3
4 2
NPSH
TM02 7310 3605
2 1
0 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Q [m³/h]
26
Technical data CR, CRE 1
Dimensional sketch
D2
D1
B2
G 1/2 G 1/2
FGJ (DIN-ANSI-JIS)
A (Oval)
B1
PN 25 / DN 25/32
G 1/2 19 x 24.5
G 1/2 Rp 1
22 M10 x 40
ø100
ø140
ø89
75
50
27
Performance curves CRI, CRN, CRIE, CRNE 1
p H
[kPa] [m]
-27 (E)
CRI, CRN 1
240
CRIE, CRNE 1
220 -25 (E)
60 Hz
ISO 9906 Annex A
2000 -23
200
-21
180
-19
1600
160
-17 (E)
140
-15
1200 120
-13 (E)
-12
100 -11
-10
800 80 -9 (E)
-8
60 -7
-6 (E)
-5
400 40
-4 (E)
-3
20 -2
0 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Q [m³/h]
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Q [l/s]
P2 Eta
[kW] [%]
0.10 50
Eta
0.08 P2 40
0.06 30
0.04 20
0.02 10
0.00 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Q [m³/h]
H NPSH
[m] [m]
10 5
QH 3500 rpm
8 4
6 3
4 2
NPSH
TM02 7311 3605
2 1
0 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Q [m³/h]
28
Technical data CRI, CRN, CRIE, CRNE 1
Dimensional sketch
D2
D1
B2
G 1/2
G 1/2
FGJ (DIN-ANSI-JIS)
B1
ø14 19 x 27
G 1/2 4 x ø13
ø105
ø140
ø89
50
ø42.2
250
22
22
34
100 180 ø32 162 ø32
150 210 ø85
210
29
Performance curves CR, CRE 3
CR, CRE 3
p H
[kPa] [m]
CR, CRE 3
240 -25 (E)
60 Hz
ISO 9906 Annex A
220 -23 (E)
2000 -21
200
180 -19
140 -15
1200 -13
120
-12
-11 (E)
100
-10
-9
800 80
-8 (E)
-7
60
-6
-5 (E)
400 40 -4 (E)
-3
20 -2 (E)
0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h]
0.08 Eta 40
0.04 20
0.00 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h]
H NPSH
[m] [m]
QH 3500 rpm
9 6
6 4
3 NPSH 2
TM02 7312 3605
0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h]
30
Technical data CR, CRE 3
Dimensional sketch
D2
D1
B2
G 1/2 G 1/2
FGJ (DIN-ANSI-JIS)
A (Oval)
B1
PN 25 / DN 25/32
G 1/2 19 x 24.5
G 1/2 Rp 1
22 M10 x 40
ø100
ø140
ø89
75
50
31
Performance curves CRI, CRN, CRIE, CRNE 3
p H
[kPa] [m]
CRI, CRN 3
240 -25 (E)
CRIE, CRNE 3
220 -23 (E) 60 Hz
ISO 9906 Annex A
2000 -21
200
180 -19
140 -15
1200 -13
120
-12
-11 (E)
100
-10
-9
800 80
-8 (E)
-7
60
-6
-5 (E)
400 40 -4 (E)
-3
20 -2 (E)
0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h]
0.08 Eta 40
0.04 20
0.00 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h]
H NPSH
[m] [m]
QH 3500 rpm
9 6
6 4
3 NPSH 2
TM02 7313 3605
0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Q [m³/h]
32
Technical data CRI, CRN, CRIE, CRNE 3
Dimensional sketch
D2
D1
B2
G 1/2
G 1/2
FGJ (DIN-ANSI-JIS)
B1
ø14 19 x 27
G 1/2 4 x ø13
ø105
ø140
ø89
50
ø42.2
250
22
22
34
100 180 ø32 162 ø32
150 210 ø85
210
33
Performance curves CR, CRE 5
CR, CRE 5
p H
[kPa] [m]
CR, CRE 5
240 -24 (E)
60 Hz
ISO 9906 Annex A
220
-22 (E)
2000
200 -20
180
-18
1600
160 -16 (E)
-15
140 -14
-13
1200 120 -12 (E)
-11
100 -10
-9 (E)
800 80 -8
-7
60 -6
-5 (E)
400 40 -4 (E)
-3
20 -2 (E)
0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
0.08 20
0.00 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
H NPSH
[m] QH 3500 rpm [m]
9 6
6 4
3 2
TM02 7314 3605
NPSH
0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
34
Technical data CR, CRE 5
Dimensional sketch
D2
D1
B2
G 1/2 G 1/2
D3
FGJ (DIN-ANSI-JIS)
A (Oval)
B1
PN 25 / DN 25/32
G 1/2 19 x 24.5
G 1/2 Rp 1
22 M10 x 40
ø100
ø140
ø89
75
20
20
35
Performance curves CRI, CRN, CRIE, CRNE 5
p H
[kPa] [m]
CRI, CRN 5
240 -24 (E)
CRIE, CRNE 5
220 60 Hz
-22 (E)
ISO 9906 Annex A
2000
200 -20
180
-18
1600
160 -16 (E)
-15
140 -14
-13
1200 120 -12 (E)
-11
100 -10
-9 (E)
800 80 -8
-7
60 -6
-5 (E)
400 40 -4 (E)
-3
20 -2 (E)
0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
0.08 20
0.00 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
H NPSH
[m] QH 3500 rpm [m]
9 6
6 4
3 2
TM02 7315 3605
NPSH
0 0
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
36
Technical data CRI, CRN, CRIE, CRNE 5
Dimensional sketch
D2
D1
B2
G 1/2
G 1/2
D3
FGJ (DIN-ANSI-JIS)
B1
ø14 19 x 27
G 1/2 4 x ø13
ø105
ø140
ø89
50
ø42.2
250
22
22
34
100 180 ø32 162 ø32
150 210 ø85
210
37
Performance curves CR, CRE 10
CR, CRE 10
p H
[kPa] [m]
280
CR, CRE 10
60 Hz
260 -17 ISO 9906 Annex A
2400 -16
240
220
-14
2000
200
1600 160
-10
140 -9 (E)
1200 -8
120
-7
100
-6 (E)
800 80 -5 (E)
-4
60
-3 (E)
400 40
-2 (E)
20 -1 (E)
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q [m³/h]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]
P2 Eta
[kW] [%]
0.8 80
0.6 Eta 60
P2
0.4 40
0.2 20
0.0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q [m³/h]
H NPSH
[m] [m]
16 3500 rpm 8
12 6
8 4
4 2
TM02 7316 3605
NPSH
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q [m³/h]
38
Technical data CR, CRE 10
Dimensional sketch
D2
D1
B2
G 1/2 G 1/2 D3
FJ (DIN-JIS) A (oval)
PN 16-25 / DN 40
B1
Rp 1 1/2"
G 1/2 18 x 20.2 G 1/2
M12 x 45
ø39
27
ø114
ø150
4 x ø13.5
20
20
80
80
39
Performance curves CRI, CRN, CRIE, CRNE 10
p H
[kPa] [m]
260
CRI, CRE 10
-17 (E)
2400
CRIE, CRNE 10
240 -16
60 Hz
ISO 9906 Annex A
220
-14
2000
200
1600 160
-10
140 -9 (E)
1200 -8
120
-7
100
-6 (E)
800 80 -5 (E)
-4
60
-3 (E)
400 40
-2 (E)
20 -1 (E)
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q [m³/h]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]
P2 Eta
[kW] [%]
0.8 80
0.6 Eta 60
P2
0.4 40
0.2 20
0.0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q [m³/h]
H NPSH
[m] [m]
16 3500 rpm 8
12 6
8 4
4 2
TM02 7317 3605
NPSH
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q [m³/h]
40
Technical data CRI, CRN, CRIE, CRNE 10
Dimensional sketch
D2
D1
B2
G 1/2
G 1/2 D3
FGJ (DIN-ANSI-JIS)
P (PJE) PN 16-25 / DN 40 CA (Flexiclamp)
B1
18.5 x 23.5
G 1/2 G 1/2 202
4 x ø13
ø115
ø150
ø87
4 x ø13
26
26
80
80
80
41
Performance curves CR, CRE 15
CR, CRE 15
p H
[kPa] [m] -12 (E)
CR, CRE 15
240
60 Hz
ISO 9906 Annex A
220
-10 (E)
2000
200
-9
180
-8 (E)
1600
160
-7
140
-6
1200 120
-5 (E)
100
-4 (E)
800 80
-3 (E)
60
-2 (E)
400 40
-1 (E)
20
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
P2 Eta
[kW] [%]
1.6 Eta 80
1.2 60
P2
0.8 40
0.4 20
0.0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
H NPSH
[m] [m]
20 3500 rpm 8
15 6
10 4
TM02 7318 3605
5 2
NPSH
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
42
Technical data CR, CRE 15
Dimensional sketch
D2
D1
B2
G 1/2
G 1/2 D3
F (DIN) GJ (ANSI-JIS)
PN 16-25 / DN 50 A (oval)
B1
ø65
ø125
ø165
ø165
ø127
90
90
130
20
43
Performance curves CRI, CRN, CRIE, CRNE 15
p H
[kPa] [m] -12 (E)
CRI, CRN 15
240
CRIE, CRNE 15
220 60 Hz
-10 (E) ISO 9906 Annex A
2000
200
-9
180
-8 (E)
1600
160
-7
140
-6
1200 120
-5 (E)
100
-4 (E)
800 80
-3 (E)
60
-2 (E)
400 40
-1 (E)
20
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
P2 Eta
[kW] [%]
1.6 Eta 80
1.2 60
P2
0.8 40
0.4 20
0.0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
H NPSH
[m] [m]
20 3500 rpm 8
15 6
10 4
5 2
TM02 7319 3605
NPSH
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
44
Technical data CRI, CRN, CRIE, CRNE 15
Dimensional sketch
D2
D1
B2
G 1/2
G 1/2 D3
FGJ (DIN-ANSI-JIS)
P (PJE) PN 16-25 / DN50 CA (Flexiclamp)
B1
ø165
ø127
ø87
26
26
90
90
90
26
45
Performance curves CR, CRE 20
CR, CRE 20
p H
[kPa] [m]
CR, CRE 20
220 -10 (E) 60 Hz
2000 ISO 9906 Annex A
200
180
-8 (E)
1600
160
-7
140
-6 (E)
1200 120
-5
100
-4 (E)
800 80
-3 (E)
60
-2 (E)
400 40
-1 (E)
20
0 0
0 4 8 12 16 20 24 28 32 Q [m³/h]
0 2 4 6 8 10 Q [l/s]
P2 Eta
[kW] [%]
1.6 P2 80
1.2 Eta 60
0.8 40
0.4 20
0.0 0
0 4 8 12 16 20 24 28 32 Q [m³/h]
H NPSH
[m] 3500 rpm [m]
20 8
15 6
10 4
5 2
TM02 7320 3605
NPSH
0 0
0 4 8 12 16 20 24 28 32 Q [m³/h]
46
Technical data CR, CRE 20
Dimensional sketch
D2
D1
B2
G 1/2
G 1/2 D3
F (DIN) GJ (ANSI-JIS)
PN 16-25 / DN 50 A (oval)
B1
ø65
ø125
ø165
ø165
ø127
90
90
130
20
47
Performance curves CRI, CRN, CRIE, CRNE 20
p H
[kPa] [m]
CRI, CRN 20
220 -10 (E)
CRIE, CRNE 20
2000 60 Hz
200
ISO 9906 Annex A
180
-8 (E)
1600
160
-7
140
-6 (E)
1200 120
-5
100
-4 (E)
800 80
-3 (E)
60
-2 (E)
400 40
-1 (E)
20
0 0
0 4 8 12 16 20 24 28 32 Q [m³/h]
0 2 4 6 8 10 Q [l/s]
P2 Eta
[kW] [%]
1.6 P2 80
1.2 Eta 60
0.8 40
0.4 20
0.0 0
0 4 8 12 16 20 24 28 32 Q [m³/h]
H NPSH
[m] 3500 rpm [m]
20 8
15 6
10 4
5 2
TM02 7321 3605
NPSH
0 0
0 4 8 12 16 20 24 28 32 Q [m³/h]
48
Technical data CRI, CRN, CRIE, CRNE 20
Dimensional sketch
D2
D1
B2
G 1/2
G 1/2 D3
FGJ (DIN-ANSI-JIS)
P (PJE) PN 16-25 / DN50 CA (Flexiclamp)
B1
ø165
ø127
ø87
26
26
90
90
90
26
49
Performance curves CR, CRE 32
CR, CRE 32
p H
[MPa] [m]
280
CR, CRE 32
-10-2
60 Hz
260 ISO 9906 Annex A
-9
2.4 -9-2
240
-8
220 -8-2
2.0
200 -7 (E)
-7-2
180
-6 (E)
1.6 160 -6-2
140 -5
-5-2 (E)
1.2 120
-4
-4-2 (E)
100
-3
0.8 80
-3-2
60 -2 (E)
-2-1 (E)
-2-2
0.4 40
-1 (E)
20 -1-1 (E)
0.0 0
0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h]
0 2 4 6 8 10 12 Q [l/s]
P2 Eta
[kW] [%]
3.2 P2 1/1 80
2.4 Eta 60
P2 2/3
1.6 40
0.8 20
0.0 0
0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h]
H NPSH
[m] [m]
32 QH 3500 rpm 1/1 16
24 12
QH 3500 rpm 2/3 NPSH
16 8
TM02 7322 3605
8 4
0 0
0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h]
50
Technical data CR, CRE 32
Dimensional sketch
D2
D1
B2
D3
G 1/2
PN16-25-40/DN65
B1
G 1/2 8 x ø18
G 1/2
ø107
ø145
ø185
105
170 ø74
223 240
320 298
51
Performance curves CRN, CRNE 32
CRN, CRNE 32
p H
[MPa] [m]
280
CRN, CRNE 32
-10-2
60 Hz
260 ISO 9906 Annex A
-9
2.4 -9-2
240
-8
220 -8-2
2.0
200 -7 (E)
-7-2
180
-6 (E)
1.6 160 -6-2
140 -5
-5-2 (E)
1.2 120
-4
-4-2 (E)
100
-3
0.8 80
-3-2
60 -2 (E)
-2-1 (E)
-2-2
0.4 40
-1 (E)
20 -1-1 (E)
0.0 0
0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h]
0 2 4 6 8 10 12 Q [l/s]
P2 Eta
[kW] [%]
3.2 P2 1/1 80
2.4 Eta 60
P2 2/3
1.6 40
0.8 20
0.0 0
0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h]
H NPSH
[m] [m]
32 QH 3500 rpm 1/1 16
24 12
QH 3500 rpm 2/3 NPSH
16 8
8 4
TM02 7323 3605
0 0
0 4 8 12 16 20 24 28 32 36 40 44 Q [m³/h]
52
Technical data CRN, CRNE 32
Dimensional sketch
D2
D1
B2
D3
G 1/2
PN16-25-40/DN65
B1
G 1/2 8 x ø18
G 1/2
ø107
ø145
ø185
105
170 ø74
226 240
320 298
53
Performance curves CR, CRE 45
CR, CRE 45
p H
[MPa] [m]
260 -7
CR, CRE 45
-7-1
-7-2 60 Hz
2.4
240 ISO 9906 Annex A
220 -6
-6-1
-6-2
2.0
200
-5
180 -5-1
-5-2
1.6 160
-4
140 -4-1
-4-2 (E)
1.2 120
-3 (E)
-3-1
100 -3-2
0.8 80
-2 (E)
-2-1 (E)
60 -2-2
0.4 40 -1 (E)
-1-1 (E)
20
0.0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
0 2 4 6 8 10 12 14 16 18 Q [l/s]
P2 P2 Eta
[hp] [kW] [%]
8 80
10
Eta
8 6 P2 1/1 60
6 P2 2/3
4 40
4
2 20
2
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
p H NPSH
[kPa] [m] [m]
400 40 QH 3500 rpm 1/1 8
200 20 4
TM02 7324 3103
100 10 2
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
54
Technical data CR, CRE 45
Dimensional sketch
D2
D1
B2
D3
G 1/2
PN16-25-40/DN80
B1
G 1/2 8 x ø18
G 1/2
ø200
ø120
ø160
140
248 266
365 331
55
Performance curves CRN, CRNE 45
CRN, CRNE 45
p H
[MPa] [m]
260 -7
CRN, CRNE 45
-7-1
-7-2 60 Hz
2.4
240 ISO 9906 Annex A
220 -6
-6-1
-6-2
2.0
200
-5
180 -5-1
-5-2
1.6 160
-4
140 -4-1
-4-2 (E)
1.2 120
-3 (E)
-3-1
100 -3-2
0.8 80
-2 (E)
-2-1 (E)
60 -2-2
0.4 40 -1 (E)
-1-1 (E)
20
0.0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
0 2 4 6 8 10 12 14 16 18 Q [l/s]
P2 P2 Eta
[hp] [kW] [%]
8 80
10
Eta
8 6 P2 1/1 60
6 P2 2/3
4 40
4
2 20
2
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
p H NPSH
[kPa] [m] [m]
400 40 QH 3500 rpm 1/1 8
200 20 4
TM02 7325 3605
100 10 2
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
56
Technical data CRN, CRNE 45
Dimensional sketch
D2
D1
B2
G 1/2 G 1/2 D3
FJ (DIN-JIS) A (oval)
PN 16-25 / DN 40
B1
Rp 1 1/2"
G 1/2 18 x 20.2 G 1/2
M12 x 45
ø39
27
ø114
ø150
4 x ø13.5
20
20
80
80
57
Performance curves CR, CRE 64
CR, CRE 64
p H
[MPa] [m]
CR, CRE 64
1.8
180 -5-2 60 Hz
-4 ISO 9906 Annex A
1.6
160 -4-1
1.4 -4-2
140
-3
1.2 120
-3-1
-2
0.8 80
-2-1 (E)
-1 (E)
0.4 40
-1-1 (E)
0.2 20
0.0 0
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
0 5 10 15 20 25 Q [l/s]
P2 P2 Eta
[hp] [kW] [%]
16 80
20 Eta
16 12 60
12 P2 1/1
8 40
8 P2 2/3
4 20
4
0 0 0
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
p H NPSH
[kPa] [m] NPSH
[m]
QH 3500 rpm 1/1
400 40 8
200 20 4
TM02 7326 3605
100 10 2
0 0 0
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
58
Technical data CR, CRE 64
Dimensional sketch
D2
D1
F (DIN)
PN25-40/DN100
B2 8 x ø22
G 1/2
ø235
ø150
ø190
ø100 4 x ø14
45
D3
266
G 1/2 331
F (DIN)
PN16/DN100
B1
G 1/2 8 x ø18
G 1/2
ø150
ø180
ø220
248 266
365 331
59
Performance curves CRN, CRNE 64
CRN, CRNE 64
p H
[MPa] [m]
CRN, CRNE 64
1.8
180 -5-2 60 Hz
-4 ISO 9906 Annex A
1.6
160 -4-1
1.4 -4-2
140
-3
1.2 120
-3-1
-2
0.8 80
-2-1 (E)
-1 (E)
0.4 40
-1-1 (E)
0.2 20
0.0 0
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
0 5 10 15 20 25 Q [l/s]
P2 P2 Eta
[hp] [kW] [%]
16 80
20 Eta
16 12 60
12 P2 1/1
8 40
8 P2 2/3
4 20
4
0 0 0
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
p H NPSH
[kPa] [m] NPSH
[m]
QH 3500 rpm 1/1
400 40 8
200 20 4
TM02 7327 3605
100 10 2
0 0 0
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
60
Technical data CRN, CRNE 64
Dimensional sketch
D2
D1
F (DIN)
PN25-40/DN100
8 x ø22
B2
G 1/2
ø235
ø150
ø190
ø100 4 x ø14
45
D3
266
G 1/2 331
F (DIN)
PN16/DN100
B1
G 1/2 8 x ø18
G 1/2
ø220
ø150
ø180
140
251 266
365 331
61
Performance curves CR, CRE 90
CR, CRE 90
p H
[MPa] [m]
170 CR, CRE 90
-4-2
1.6 60 Hz
160
ISO 9906 Annex A
150 -3
1.4
140
-3-1
130
1.2
120
-3-2
110
1.0 100 -2
90
-2-1 (E)
0.8 80
70 -2-2 (E)
0.6 60
50 -1 (E)
0.4 40
-1-1 (E)
30
0.2 20
10
0.0 0
0 20 40 60 80 100 120 140 Q [m³/h]
0 10 20 30 40 Q [l/s]
P2 Eta
[kW] Eta [%]
16 80
12 P2 1/1 60
P2 2/3
8 40
4 20
0 0
0 20 40 60 80 100 120 140 Q [m³/h]
H NPSH
[m] QH 3500 rpm 1/1 [m]
40 16
QH 3500 rpm 2/3
30 12
NPSH
20 8
10 4
TM02 7328 3605
0 0
0 20 40 60 80 100 120 140 Q [m³/h]
62
Technical data CR, CRE 90
Dimensional sketch
D2
D1
F (DIN)
PN25-40/DN100
8 x ø22
B2
G 1/2
ø235
ø156
ø190
4 x ø14
45
D3 ø100
280
G 1/2 348
F (DIN)
PN16/DN100
B1
8 x ø18
G 1/2
G 1/2
ø220
ø156
ø180
140
261 280
380 348
63
Performance curves CRN, CRNE 90
CRN, CRNE 90
p H
[MPa] [m]
170 CRN, CRNE 90
-4-2
1.6 60 Hz
160
ISO 9906 Annex A
150 -3
1.4
140
-3-1
130
1.2
120
-3-2
110
1.0 100 -2
90
-2-1 (E)
0.8 80
70 -2-2 (E)
0.6 60
50 -1 (E)
0.4 40
-1-1 (E)
30
0.2 20
10
0.0 0
0 20 40 60 80 100 120 140 Q [m³/h]
0 10 20 30 40 Q [l/s]
P2 Eta
[kW] Eta [%]
16 80
12 P2 1/1 60
P2 2/3
8 40
4 20
0 0
0 20 40 60 80 100 120 140 Q [m³/h]
H NPSH
[m] QH 3500 rpm 1/1 [m]
40 16
QH 3500 rpm 2/3
30 12
NPSH
20 8
10 4
TM02 7329 3605
0 0
0 20 40 60 80 100 120 140 Q [m³/h]
64
Technical data CRN, CRNE 90
Dimensional sketch
D2
D1
F (DIN)
PN25-40/DN100
B2 8 x ø22
G 1/2
ø235
ø156
ø190
ø100 4 x ø14
45
D3
280
G 1/2 348
F (DIN)
PN16/DN100
B1
G 1/2 8 x ø18
G 1/2
ø235
ø156
ø180
140
261 280
380 348
65
Motor data CR, CRI, CRN, CRE, CRIE, CRNE
Siemens
15 160 380-480∆/660-690Y 27.5-22/15.8-15.8 0.92-0.9 89.5-91 165-200.2/94.8-94.8
18.5 160 380-480∆/660-690Y 34-26.5/19.6-19.6 0.93-0.92 89-91 197.2-233.2/113.7-113.7
22 180 380-480∆/660-690Y 39.5-32.5/23-21.5 0.9-0.86 93.5-94.5 260.7-273/151.8-180.6
380-480∆/660-690Y
66
Motor data CR, CRI, CRN, CRE, CRIE, CRNE
MMGE
11 160 3 380-415 21.4 0.93 84
15 160 3 380-415 28 0.94 85.5
18.5 160 3 380-415 34 0.95 85.5
67
Pumped liquids CR, CRI, CRN, CRE, CRIE, CRNE
1s, 1, 3, 5
10, 15, 20
10, 15, 20
68
Pumped liquids CR, CRI, CRN, CRE, CRIE, CRNE
1s, 1, 3, 5
1s, 1, 3, 5
10, 15, 20
10, 15, 20
Pumped liquid Note
temperature
69
Accessories CR, CRI, CRN, CRE, CRIE, CRNE
Pipework connection
For pipework connection, various sets of counter
flanges and couplings are available.
ø19
Threaded 16 bar, EN 1092-2 Rp 1¼ 419901
TM03 0400 3705
CR 1s
CR(E) 1
CR(E) 3
ø78 CR(E) 5
ø100 For welding 25 bar, EN 1092-2 32 mm, nominal 419902
ø140
ø19
Threaded 16 bar, EN 1092-2 Rp 2 339903
TM03 0402 3705
ø102
ø125 Threaded 16 bar, special flange RP 2½ 339904
ø165
19.5
TM02 7203 2803
ø127
CR(E) 15 RP 2½
Threaded 16 bar, special flange 96509578
18.5
CR(E) 20
ø102
ø125
ø165
ø19
For welding 25 bar, EN 1092-2 50 mm, nominal 339901
TM03 0402 3705
ø102
ø125
For welding 40 bar, special flange 65 mm, nominal 339902
ø165
Rp 2½ / 16 bar Rp 3 / 16 bar 40 bar For welding 16 bar, special flange 80 mm, nominal 349903
70
Accessories CR, CRI, CRN, CRE, CRIE, CRNE
ø132
ø160 For welding 40 bar 80 mm, nominal 350542
ø200
ø19 ø22
Threaded 16 bar, EN 1092-2 Rp 4 369901
71
Accessories CR, CRI, CRN, CRE, CRIE, CRNE
ø19
CRI(E),
CRN(E)
1s, 1, 3 and
ø78 5
ø100 For welding 25 bar, EN 1092-2 32 mm, nominal 415305
ø140
ø19
TM03 0401 3705
21
TM02 7202 2803
ø115
ø89
ø110
ø150
CRI(E) 10
ø19
CRN(E) 10
TM03 0401 3705
21
TM02 7202 2803
ø115
ø89
ø110
ø150
72
Accessories CR, CRI, CRN, CRE, CRIE, CRNE
19.5
Rp 2½
ø102 Threaded 16 bar, special flange 96509579
ø125 CRI(E) 15,
ø165
20
CRN(E) 15,
ø19
20
TM03 0402 3705
19.5
TM00 7203 2803
ø127
ø102
ø125
ø165
ø132
ø160 For welding 40 bar 80 mm, nominal 350545
ø200
ø19 ø22
Threaded 16 bar Rp 4 369904
TM03 2118 3705
CRN(E) 64
For welding 16 bar 100 mm, nominal 369903
CRN(E) 90
ø158 ø162
ø180 ø190
ø220 ø235
For welding 40 bar 100 mm, nominal 369906
16 bar 40 bar
Flange with 20 mm higher collar. With this collar, the installation dimensions of a CR 20 will be identical to those of a CR 32.
If a CR 32 is replaced with a CR 20, the base must be raised by 15 mm.
73
Accessories CR, CRI, CRN, CRE, CRIE, CRNE
Number of
Pipework Rubber coupling Product
Coupling Pump type Pipe stub PN
connection parts sets number
needed
EPDM 2 419911
Threaded 80 bar R 1¼
CRI(E), FKM 2 419905
CRN(E)
1, 3 and 5 EPDM 2 419912
For welding 80 bar DN 32
FKM 2 419904
EPDM 2 339911
Threaded 70 bar R2
TM00 3808 1094
Rp 1 Klingersil 1 96449748
Oval
TM02 7368 3303
(cast iron)
RP 1¼ Klingersil 1 96449749
50 210
RP 1 Klingersil 2 96449746
A Oval
B (stainless steel)
RP 1¼ Klingersil 2 96449747
EPDM 2 96449743
TM02 7369 3303
Union G2 50 228
A
B FKM 2 96449744
EPDM 2 96449745
TM02 7370 3303
CRI(E),
CRN(E) DIN DN 25
75 250
1, 3 and 5 (stainless steel) DN 32
A FKM 2 96449900
B
EPDM 2 405280
Rp 1
FKM 2 405281
EPDM 2 415296
RP 1¼
Clamp, FKM 2 415297
208
threaded pipe stub EPDM 2 405291
NPT 1
FKM 2 405292
50
EPDM 2 415311
A NPT 1¼
TM02 7371 3303
B FKM 2 415312
EPDM 2 405282
28.5 -
Clamp, pipe stub FKM 2 405283
for welding EPDM 2 415300
37.2 -
FKM 2 415301
74
Accessories CR, CRI, CRN, CRE, CRIE, CRNE
Number of
Pipework Rubber Product
Base connection Pump type Connection A B coupling
connection parts number
sets needed
RP 1¼ Klingersil 2 96498775
Oval
Rp 1½ Klingersil 2 96498727
(cast iron)
Rp 2 Klingersil 2 96498836
80 260
EPDM 2 96500275
TM02 7374 3303
Union G 2¾ 80 288
A FKM 2 96500276
B
EPDM 2 96498840
FGJ
(Cast iron)
FKM 2 96500119
DN 40
EPDM 2 96500263
FGJ
(Stainless steel)
CRI(E), FKM 2 96500264
CRN(E) 10 80 316
EPDM 2 96500265
A FGJ
TM02 7373 3303
B (Cast iron)
FKM 2 96500266
DN 50
EPDM 2 96500257
FGJ
(Stainless steel)
FKM 2 96500269
EPDM 2 425238
Rp 1½
FKM 2 425239
259
Clamp, EPDM 2 335241
threaded pipe Rp 2
stub FKM 2 335242
EPDM 2 96508600
Rp 2½ 80 346
FKM 2 96508601
A
B
EPDM 2 425242
48.3 (DN 40) -
TM02 7375 3303
FKM 2 425243
Clamp, pipe stub
for welding
EPDM 2 335251
60.3 (DN 50) -
FKM 2 335252
75
Accessories CR, CRI, CRN, CRE, CRIE, CRNE
Number of
Pipework Rubber Product
Base connection Pump type Connection A B coupling
connection parts number
sets needed
RP 1¼ Klingersil 2 96498775
Oval
Rp 1½ Klingersil 2 96498727
(cast iron)
Rp 2 Klingersil 2 96498836
90 260
EPDM 2 96500275
TM02 7374 3303
Union G 2¾ 90 288
A FKM 2 96500276
B
EPDM 2 96498840
FGJ
(Cast iron)
FKM 2 96500119
DN 40
EPDM 2 96500263
FGJ
CRI(E), (Stainless steel)
FKM 2 96500264
CRN(E) 90 334
15, 20 EPDM 2 96500265
A FGJ
TM02 7373 3303
B (Cast iron)
FKM 2 96500266
DN 50
EPDM 2 96500267
FGJ
(Stainless steel)
FKM 2 96500269
EPDM 2 425238
Rp 1½
FKM 2 425239
259
Clamp, EPDM 2 335241
threaded pipe Rp 2
stub FKM 2 335242
EPDM 2 96508600
Rp 2½ 90 346
FKM 2 96508601
A
B
EPDM 2 425242
48.3 (DN 40) -
TM02 7375 3303
FKM 2 425243
Clamp, pipe stub
for welding
EPDM 2 335251
60.3 (DN 50) -
FKM 2 335252
76
Accessories CR, CRI, CRN, CRE, CRIE, CRNE
G10-LON interface for CRE, CRIE, EMC-filter for CRE, CRIE, CRNE
CRNE EMC-filter required for installation of 11-22 kW E-
The G10-LON interface is used in connection with data pumps in residential areas.
transmission between a Locally Operating Network Product Product number
(LON) and electronically controlled Grundfos pumps EMC-filter (11 kW)
applying the Grundfos bus-protocol GENIbus. EMC-filter (15 kW)
96478309
Product Product number EMC-filter (18.5 kW)
Extension
Voltage Cable Product
Dry-running protection Pump type LiqTec Sensor ½" cable
[V] 5m number
15 m
200-240 z z z - 96556429
116 mm
CR(E)
CRI(E) 80-130 z z z - 96556430
CRN(E)
TM03 2108 3705
- - - - z 96443676
90 mm
77
Accessories CR, CRI, CRN, CRE, CRIE, CRNE
Flowmeter
SITRANS F M MAGFLO
Siemens 3 - 10 m3 ID8286
MAG 5100 W (DN 40)
SITRANS F M MAGFLO 3
Flowmeter Siemens 6 - 30 m ID8287
MAG 5100 W (DN 65)
Flowmeter
SITRANS F M MAGFLO
Siemens 20 - 75 m3 ID8288
MAG 5100 W (DN 100)
Temperature sensor TTA (0) 25 Carlo Gavazzi 0°C to +25°C 96432591
Temperature sensor TTA (-25) 25 Carlo Gavazzi –25°C to +25°C 96430194
Temperature sensor TTA (50) 100 Carlo Gavazzi +50°C to +100°C 96432592
Temperature sensor TTA (0) 150 Carlo Gavazzi 0°C to +150°C 96430195
Protecting tube
Carlo Gavazzi 96430201
ø9 x 50 mm
Accessory for temperature sensor.
Protecting tube
All with ½ RG connection Carlo Gavazzi 96430202
ø9 x 100 mm
Cutting ring bush Carlo Gavazzi 96430203
Temperature sensor, tmg
WR 52 –50°C to +50°C ID8295
ambient temperature (DK: Plesner)
Differential temperature sensor ETSD Honsberg 0°C to +20°C 96409362
Differential temperature sensor ETSD Honsberg 0°C to +50°C 96409363
Note: All sensors have 4-20 mA signal out-put.
Danfoss pressure sensor kits for CRE, CRIE, CRNE 1, 3, 5, 10, 15, 20, 32, 45, 64 and 90
Kit consisting of.. Pressure range Temperature range Product number
• Danfoss pressure transmitter, type MBS 3000, 0 - 4 bar 96428014
with 2 m screened cable 0 - 6 bar 96428015
Connection: G ½ A (DIN 16288 - B6kt)
0 - 10 bar –40°C to +85°C 96428016
• 5 cable clips (black)
0 - 16 bar 96428017
• Instruction manual PT (00 40 02 12)
0 - 25 bar 96428018
78
Variants CR, CRI, CRN, CRE, CRIE, CRNE
79
Further product CR, CRI, CRN, CRE, CRIE, CRNE
documentation
WinCAPS
WinCAPS is a Windows-based Computer Aided Prod-
uct Selection program containing information on more
than 90,000 Grundfos products.
Available on CD-ROM in more than 15 languages, Win-
cd-wincaps
CAPS offers
• detailed technical information
• selection of the optimum pump solution
Fig. 28 WinCAPS CD-ROM
• dimensional drawings of each pump
• detailed service documentation
• installation and operating instructions
• wiring diagrams of each pump.
WinCAPS
Fig. 29 WinCAPS
80
Further product CR, CRI, CRN, CRE, CRIE, CRNE
documentation
WebCAPS
WebCAPS is a Web-based Compute Aided Product
Selection program and a web-version of WinCAPS.
WebCAPS is accessible on Grundfos’ homepage,
www.grundfos.com, and offers
• detailed technical information
• dimensional drawings of each pump
• wiring diagrams of each pump.
Click Literature to se- Click Service to Click Replacement Being a registered user
lect and download find information on and select the right click Log in to:
Grundfos documenta- service kits and replacement pump – save your settings
tion by browsing the spare parts. based on the current – define and save your
product ranges or per- installation. own units
forming a specific – save personalised in-
search. Click CAD drawings to formation.
Literature includes: Click Search and select and download
Click Catalogue and – data booklets select a product Click Sizing and CAD drawings in:
select a product from – installation and ope- from the exten- select the most –.stp Click Settings and
the extensive prod- rating instructions sive product cat- suitable pump for –.dxf select your preferred
uct catalogue. – service etc. alogue. your application. –.dwg options.
WebCAPS_English
Fig. 30 WebCAPS
81
Further product CR, CRI, CRN, CRE, CRIE, CRNE
documentation
82
Further product CR, CRI, CRN, CRE, CRIE, CRNE
documentation
83
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence
96488672 1105
Repl. 96488672 0405
GB
Subject to alterations.
www.grundfos.com