Beruflich Dokumente
Kultur Dokumente
1. Tank design input summary
Internal shell diameter D= 13.000,00
mm Shell height H= 16.000,00 mm
Number of courses: 7
Roof type: Sloped, conical, with rafters
Roof diameter: 13016,00 mm Slope angle: θ= 10,00 degrees
Roof radius R= 6608,40 mm Radius of roof curvature: R1= 37,48 m
Fluid name:
Max capacity: 8.494,87 m3 (Volume between tank bottom and the top)
Trmperature:
Max operating temperature: 40,00 °C
LODMAT: ‐ 21,00 °C
Min design metal temp.: ‐ 28,00 °C
Max design temp.: 60,00 °C
Corrosion allowance:
Shell: 3,00 mm Bottom: 3,00 mm
Roof: 1,00 mm (Steel plates internal and external painting is mandatory)
Nominal plates widths:
First lowest shell course 1 2000,00 mm
2 2000,00 mm
3 2000,00 mm
4 2000,00 mm
5 2000,00 mm
6 2000,00 mm
7 2000,00 mm
8 2000,00 mm
9 0,00 mm
10 0,00 mm
Max liquid level:
HHLL: 15000,00 mm
Failure case: ‐ mm
Load data:
Wind load: 0,58 kN/m2 580,00 N/m2
Zone wind velocity: 30,00 m/s 108,00 km/h
3 sec. Wind gust velocity (SR EN 14015): 45,00 m/s 162,00 km/h
Snow load: 2,00 kPa 2.000,00 N/m2
Live load (roof): 2,50 kPa 2.500,00 N/m2
Seismic load:
Period of contrac. Tc= 1,60 s
Acceleration 0,25 *g
Lateral force coeff. G1= 0,25
Site coeff. j= 1,50 (Table G.1)
Insulation: no ‐ mm
Material and mechanical properties of steel plates:
Max
Minimum allowable
tensile Minimum yield design Max allowable
strength strength stress hydrotest
Material [N/mm2] [N/mm2] [N/mm2] [N/mm2]
Ft Fy S St
Roof S235J0 430,00 235,00 156,67 176,25
Shell S235J0 430,00 235,00 156,67 176,25
Bottom S235J0 430,00 235,00 156,67 176,25
2. Shell design
Minimum shell thickness as per 9.1.5 (Table 16):
tmin= 5 mm
Shell thickness calculation (acc to 9.2.2):
3. Bottom plate design
Minimum thickness as per 8.2.3 (Table 13): 6,00 mm
Adding corrosion allowance, required thickness is: 9,00 mm
Therefore, use thickness of: eb= 9,00 mm is satisfactory
Minimum width of plates overlaping as per 8.1 (Figure 3): 45,00 mm
4. Annular plate design
As per 8.3.1, min thickness of the plate is: 6,00 mm
Adding corrosion allowance, required thickness is: 9,00 mm
Therefore, use thickness of: ea= 9,00 mm is satisfactory
Thr minimum width la as per 8.3.3 is: 540,00 mm
Therefore, use width of: la= 540,00 mm is satisfactory.
The distance ld ‐ outside projection of annular plates shall be in the interval 50 to 100 mm (as per 8.3.3):
Therefore, use width of: ld= 50,00 mm is satisfactory.
Minimum width of bottom and annular plates overlaping, as per 8.4.1, is: 60,00 mm
Therefore, use width of: lw= 60,00 mm is satisfactory.
Total width of annular plate is: 658,00 mm
5. Intermediate wind girders
As per 9.3.3.1, minimum dimensions of angle (shown on detail c) is: L 100x65x8
Shell
thickness Unit weight of
corroded Actual plate Transposed wind girder
Course [mm] width [m] widht [m] [kg/m]
1 5,00 2,00 1,14 9,86 kg/m
2 5,00 2,00 1,14
3 4,00 2,00 2,00
4 4,00 2,00 2,00
5 4,00 2,00 2,00
6 4,00 2,00 2,00
7 4,00 2,00 2,00
8 4,00 2,00 2,00
9 ‐ ‐ ‐
10 ‐ ‐ ‐
Factor K: K= 9,39
Maximum permitted spacing of secondary stiffening rings:
Hp= 6,41 m
Minimum number of intermediate wind girders required is 2
Location of intermedaite wind girders from top of the tank: Weight [kg]
1 4,76 m 402,69
2 9,53 m 402,69
3 ‐ m ‐
4 ‐ m ‐
5 ‐ m ‐
6. Roof plate design
Minimum thickness as per 10.3.3: 5,00 mm
Adding corrosion allowance, required thickness is: 6,00 mm
Therefore, use thickness of: er= 7,00 mm is satisfactory
7. Roof‐to‐shell joint design
8. Weight summary
Shell courses: 37210,36 kg
Bottom plates: 9545,64 kg
Compresion ring:
Unit weight of actual compression ring is: 5,369 kg/m
Total weight of compression ring is: 219,51 kg
Weight of intermediate wind girders: 805,38 kg
Roof plates: 7538,93 kg
Miscellaneous:
Assuming 10,00 % of total weight: 5531,98 kg
Operating liquid weight: 1543012,87 kg
Hydrostatic liquid weight: 2123716,63 kg
ERECTION WEIGHT: 60.852 kg
OPERATING WEIGHT: 1.603.865 kg
HYDROSTATIC TEST WEIGHT: 2.184.568 kg