CONTROL CABINET (240v)

Ø50 PRESSURE PIPE


Ø32 CONDUIT

TUNDISH
NON-EMULSIFYING
PUMP
BUNDED BUNDED INDUSTRIAL WASTE
WASHBAY AREA ACCESS GRATING SEPARATOR AREA SAMPLING POINT
WASTE OIL OIL SEPARATOR
20L
LIFT OUT
SILT BASKET
Ø50 PRESSURE PIPE BUND DRAIN
VENT Ø100 DWV
Ø80 MINIMUM Ø50 DWV
DISCHARGE TO SEWER
HIGH FLOAT ON
FLOAT SWITCHES
PUMP ON
PUMP OFF
OIL SEPARATOR DETAILS
REFER TO NOTES FOR MORE INFORMATION
FOOT STRAINER
COLLECTION PIT
APPLICABLE MODELS FLOW RATE
TS1000 PE 1000 L/hr
TS1500 PE 1500 L/hr
TS2000 PE 2000 L/hr
TS2500 PE 2500 L/hr
DESIGN: RD DATE: 17-08-2015
NOTES: Office Branch
Sydney TITLE:
Adelaide DRAWN: DN SCALE: NA @ A4
1. THIS IS A SCHEMATIC REPRESENTATION ONLY, SITE SPECIFIC INSTALLATION MAY DIFFER 6. WASH LINE TO HAVE AN APPROVED RPZ DEVICE INSTALLED IN ACCORDANCE WITH Perth
2. LOCAL PLUMBING REGULATIONS SHOULD BE CHECKED PRIOR TO INSTALLATION LOCAL PLUMBING REGULATIONS Brisbane ROOFED WASHBAY LAYOUT CHECKED: RD SHEET 1 OF 1
3. PRESSURE PIPE DIAMETER MUST BE CHECKED AGAINST PUMP MANUAL FOR CORRECT PIPE 7. QUICK BREAK DETERGENTS MUST BE USED AT ALL TIMES, USE OF SOLVENT
DIAMETER TO ENSURE PUMP WARRANTY IS NOT VOID BASED DETERGENTS MAY EFFECT EFFICIENCY OF THE UNIT SINGLE PIT GRAVITY DISCHARGE PROJECT NO: DRAWING NO: REVISION:
Melbourne Head Office
4. PIPE MATERIAL SHOULD BE IN ACCORDANCE WITH LOCAL PLUMBING REGULATION 8. ALL ELECTRICAL CONNECTIONS ARE TO COMPLY WITH LOCAL REGULATIONS
9. ALL GRAVITY CONNECTIONS TO BE 1:60 OR TO SUIT LOCAL PLUMBING
40 Latitude Blvd P: 1800 353 788 (POLYETHYLENE SEPARATOR) AA902-12PE A
5. COLLECTION PIT MINIMUM CAPACITY MAY APPLY DEPENDING ON INSTALLATION LOCATION Thomastown F: 03 9466 1006
REGULATIONS Vic: 3074 Email:melbourne@cleanawater.com.au