Beruflich Dokumente
Kultur Dokumente
Summary This is the error description for the Variodyn VF080DC/VF130DC/VF210DC drive given in
SMLCD or CADI TX.
1 * General Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 * Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.1 700 Memory Fail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2 * 701 SW Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.3 * 702 Comm Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.4 704 Encoder Fail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.5 705 Speed Diff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.6 * 706 SpeedRefMiss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.7 * 707 SGRW Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.8 * 708 SGR/SH Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.9 709 Safty Cric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.10 * 712 PowerEIFail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.11 * 714 Current Not Zero (SA PCB SW >2.01) . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.12 717 OVERT HS Lim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.13 * 718 DCL OvervTrig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.14 * 719 DCL Overvolt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.15 720 DCL Undervolt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.16 * 724 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.17 725 Overt KTHBR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 2/16
1 * General Notes
Summary This document is available in two forms: As printed paper for the field people using the
SMLCD and as help on the CADI.
Handling
SMLCD Display Action Descrption
Select and confirm Show
function in ErrorLog menu
Handling
Each error massage consists of:
• Error number,
• Error name,
• Date/Time and
• Extra Info.
One error name can include several errors depending on motor - or mains inverter. They
differ from the Extra Info.
Note!
If the red LED on SA PCB (A7) is ON, an error has stopped or blocked the frequency
converter. In this case the error must be remedy:
1) Switch F1 OFF and
2) switch F1 ON
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 3/16
Default Error Fail
Filter Error No. Description Error Limit Error Window
700 Memory Fail 2 5
701 SW Warning 0 0
702 Comm Failure 0 0
703 Not used 0 0
704 Encoder Fail 2 4
705 Speed Diff 0 4
706 SpeedRefMiss 5 10
707 SGRW Failure 2 5
708 SGR/SH Fail 4 10
709 Safety Circ 0 0
710 Not used 0 0
711 Not used 0 0
712 PowerEIFail 2 4
713 Not used 0 0
714 CurrentNotZero 0 0
715 Not used 0 0
716 Not used 0 0
717 OVERT HS Lim 5 10
718 DCLOvervTrig 2 10
719 DCL Overvolt 2 4
720 DCLUndervolt 2 4
721 DCLUnsym. Volt 2 0
722 Not used 0 0
723 Not used 0 0
724 Power Supply 3 10
725 Overt KTHBR 2 4
Default Error Fail Filter
Note!
Warning limit and warning window are not used. To obtain the default error fail filter, follow
the below-mentioned procedure:
1) Set the drive to "Not commissioned" using CADI or SMLCD
2) Switch F1 OFF and ON
3) Press "Reset" on GCIO 360 PCB once. Wait until the elevator control has booted.
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 4/16
2 * Error
Incorrect Internal
Data Extra Info Inverter Possible Cause Fault Rectificaton
Communication
00 25 Mains Incorrect internal data Check wiring between
00 26 communication between SK A5.X121 and A3.X121
PCB (A5) and SR PCB (A3)
Download actual datafile of
SR PCB (A3
Replace SK PCB (A5)
Replace SR PCB (A3)
26 00 Motor Incorrect internal data Check wiring between
communication between SA A7.X121 and A4.X121
PCB (A7) and SR PCB (A4)
Download actual datafile of
SR PCB (A4) SA PCB (A7)
Replace SA PCB (A7)
Replace SR PCB (A4)
44 00 Motor Incorrect internal data Check wiring between
45 00 communication between SK A6.X121 and A4.X123
PCB (A6) and SR PCB (A4)
Download actual datafile of
SR PCB (A4)
Replace SK PCB (A6)
Replace SR PCB (A4)
Memory Fail
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 5/16
2.2 * 701 SW Warning
Detection of
Abnormal Extra Info Inverter Possible Cause Fault Rectificaton
Behaviour of
11 00 Motor No EEPROM identification Download actual basic
Software and
Hardware software
00 11 Mains No EEPROM identification Download actual basic
software
19 00 Motor Wrong parameter Download actual datafile of
29 00 WS (A2) and SR PCB (A4)
41 00
00 19 Mains Wrong parameter Download actual datafile of
00 29 WS (A1) and SR PCB (A4)
00 41
30 00 Motor SR PCB (A4) and basic Download actual basic
software inconsistent software
Download actual datafile of
SR PCB (A4)
00 30 Mains SR PCB (A3) and basic Download actual basic
software inconsistent software
Download actual datafile of
SR PCB (A3)
38 00 Motor Bad configuration mode Download actual basic
software
Download actual datafile of
SR PCB (A4)
00 38 Mains Bad configuration mode Download actual basic
software
Download actual datafile of
SR PCB (A3)
42 00 Motor SR PCB (A4) in boot mode Reset to normal mode:
• Switch F1 OFF and ON
• Wait until LED H1 (green)
is on
00 42 Mains SR PCB (A3) in boot mode Reset to normal mode:
• Switch F1 OFF and ON
• Wait until LED H1 (green)
is on
SW Warning
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 6/16
2.3 * 702 Comm Failure
Communication
Error Extra Info Inverter Possible Cause Fault Rectificaton
16 00 Motor Incorrect communication Replace SR PCB (A4)
00 16 Mains Incorrect communication Replace SR PCB (A3)
20 00 Motor Incorrect communication Switch F1 OFF and ON
If the error still exists, replace
SR PCB (A4)
00 20 Mains Incorrect communication Switch F1 OFF and ON
if the error still exists, replace
SR PCB (A3)
21 00 Motor Incorrect communication Check wiring A2.X122 and
between WS PCB (A2) and A4.122
SR PCB (A4)
Replace WS PCB (A2)
Replace SR PCB (A4)
00 21 Mains Incorrect communiation Check wiring A1.X122 and
between WS PCB (A1) and A3.122
SR PCB (A3)
Replace WS PCB (A1)
Replace SR PCB (A3)
25 00 Motor Incorrect communiation Check wiring A7.X121 and
between SA PCB (A7) and A4.121
SR PCB (A4)
Check Motor Control
parameter using CADI:
• Control
• Inverter
• Supervisor
• Motor
• Reserve
Replace SA PCB (A7)
Replace SR PCB (A4)
Comm Failure
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 7/16
2.4 704 Encoder Fail
Missing Encoder
Feedback Extra Info Inverter Possible Cause Fault Rectificaton
23 00 Motor Encoder cable defective or bad Check encoder wiring and
contact shielding
Encoder not fitted properly Fit the encoder correctly
Encoder suppy incorrect Check jumper S5 on SR PCB
(A4)
Standard power supply:
+5 = +5 VDC
Encoder defective Replace encoder
Encoder Fail
Overspeed of
Rotation Extra Info Inverter Possible Cause Fault Rectificaton
(max. +8 %)
17 00 Motor Speed limit of rotation Check Reserve 4 (N nom)
exceeded (N nom + 8 %)
Check encoder wiring and
encoder
Speed Diff
Speed Difference
between Extra Info Inverter Possible Cause Fault Rectificaton
Reference and
Actual Value is 52 00 Motor Wrong parameter Check Inertia
>8% Check Reserve 4 (N om)
Check Reserve 5 (l max)
LMS not working properly Check load measuring
system
Encoder not fitted properly Fit the encoder correctly
Encoder defective Replace encoder
SpeedRefMiss
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 8/16
2.7 * 707 SGRW Failure
Charging Faulty
Extra Info Inverter Possible Cause Fault Rectificaton
00 10 Mains Wiring mistake Check wiring
Contactor SGRW faulty Replace SGRW
Dirty auxiliary contacts Clean
Charging resistors defective Check the charging resistors
Bad formation of capacitor Execute Capacitor Forming
Test
Mains undervoltage Check the mains
WS PCB (A1) faulty Replace WS PCB (A1)
10 00 Motor DC Link measurement faulty Check wiring A2.XB144 pin 1
and 5
SGRW Failure
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 9/16
2.8 * 708 SGR/SH Failure
FE PCB/SH
Faulty Extra Info Inverter Possible Cause Fault Rectificaton
00 01 Mains Mains undervoltage Check the mains voltage
DC Link measurement faulty Check wiring A1.XB144 pin 1
and 5
Replace WS PCB (A1)
NE PCB (A9) defective or Check wiring to SR PCB (A3)
wrong wiring
Replace NE PCB (A9)
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 10/16
2.9 709 Safty Cric
Power Module
Error Extra Info Inverter Possible Cause Fault Rectificaton
13 00 Motor General error of the power See additional massages
module.
00 13 Mains General error of the power See additional massages
module.
14 00 Motor Error in phase L+
Wiring mistake Check wiring
Short circuit in L+ against earth Check ouput L+
Wrong parameter Download actual datafile of
WS PCB (A2)
Power module V4 faulty Replace power module V4
(VF210DC: V4 - V5) (VF210DC: V4 - V5)
00 14 Mains Error in phase V3
Wiring mistake Check wiring
Short circuit in V3 against Check ouput V3
earth or mains
Wrong parameter Download actual datafile of
WS PCB (A1)
Power module V3 faulty Replace power module V3
50 00 Motor Error in phase L-
Wiring mistake Check wiring
Short circuit in L- against earth Check ouput L-
Wrong parameter Download actual datafile of
WS PCB (A2)
Power module V5 faulty Replace power module V5
(VF210DC: V7 - V8) (VF210DC: V7 - V8)
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 11/16
Extra Info Inverter Possible Cause Fault Rectificaton
00 50 Mains Error in phase V2
Wiring mistake Check wiring
Short circuit in V2 against Check ouput V2
earth or mains
Wrong parameter Download actual datafile of
WS PCB (A1)
Power module V2 faulty Replace power module V2
00 51 Mains Error in phase V1
Wiring mistake Check wiring
Short circuit in V1 against Check ouput V1
earth or mains
Wrong parameter Download actual datafile of
WS PCB (A1)
Power module V1 faulty Replace power module V1
68 00 Motor Current not symmetrical See additional massages
PowerEIFail
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 12/16
2.12 717 OVERT HS Lim
Temperature
Limit of the Heat- Extra Info Inverter Possible Cause Fault Rectificaton
sink Exceeded
07 00 Motor Defective fan Check fan V4 - V6
(max. 80° C)
(VF210DC: V4 - V8)
Ambient Fan wiring mistake Check wiring V4 - V6
Temperature (VF210DC: V4 - V8)
Limit 40° C
Blocked heatsink Check heatsink
NTC wiring mistake Check NTC wiring
NTC sensor defective Replace module V6
00 07 Mains Defective fan Check fan V1 - V3
Fan wiring mistake Check wiring of fan V1 - V3
Blocked heatsink Check heatsink
22 00 Motor NTC wiring mistake Check NTC wiring
NTC sensor defective Replace module V6
48 00 Motor Defective fan Check fan V4 – V6
(VF210DC: V4 - V8)
Blocked heatsink Check heatsink
Fan wiring mistake Check wiring of fan V4 - V8
(VF210DC: V4 - V8)
00 48 Mains Defective fan Check fan V1 - V3
If necessary clean the
heatsink or replace the fan
Blocked heatsink Check heatsink
Fan wiring mistake Check wiring of fan V1 - V3
OVERT HS Lim
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 13/16
2.14 * 719 DCL Overvolt
DC Link
Overvoltage Extra Info Inverter Possible Cause Fault Rectificaton
03 00 Motor Wrong DC link measurement Check the DC-link
VF080DC:
Uzkmax = 455 V measurement
VF130/210DC: DC link capacitor faulty Replace power module
Uzkmax = 780 V
00 03 Mains Wrong DC link measurement Check the DC-link
VF080DC: measurement
Uzkmax = 455 V
VF130/230DC DC link capacitor faulty Replace power module
Uzkmax = 770 V
NE PCB (A9) defective or Check wiring
wrong wiring
Replace NE PCB (A9)
Wrong parameter Download actual software of
SR PCB (A3)
DCL OvervTrig
DC Link
Overvoltage Extra Info Inverter Possible Cause Fault Rectificaton
04 00 Motor Mains supply unstable or Check the mains supply
power failure voltage using an oscilloscope
SH contactor faulty Replace SH contactor
Mains power module or Replace power module
capacitor faulty
00 04 Mains Mains supply unstable or Check the mains supply
power failure voltage using an oscilloscope
SH contactor faulty Replace SH contactor
Mains power module or Replace power module
capacitor faulty
DCL Undervolt
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 14/16
2.16 * 724 Power Supply
Power Supply
Failure Extra Info Inverter Possible Cause Fault Rectificaton
Limit:
15 00 Motor 24 VDC power supply (N1) or Check 24 VDC power supply
+15 V = +13.5 V WS PCB (A1) defective and wiring to A1
-15 V = -13.5 V Too high load due to defective Disconnect each fan V4 - V8
fan and check supply voltage on
WS PCB (A2)
Disconnected A2. XB146 and
check supply voltage on SR
PCB (A4)
Limit: 00 15 Mains 24 VDC power supply (N1) or Check 24 VDC power supply
+15 V = +13.5 V WS PCB (A1) defective and wiring to A1 V4 - V8
-15 V = -13.5 V Too high load due to defective Disconnect each fan V1 - V3
fan and check supply voltage on
WS PCB (A1)
Disconnected A1. XB146 and
check supply voltage on SR
PCB (A3)
18 00 Motor Ground fault at the inverter Check motor cable
output terminal L+, L- or
excessively capacitance with Measure the ohmic resistor of
respect to ground due to long motor power modules respect
motor cable to ground
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 15/16
2.17 725 Overt KTHBR
Error Description
K 604409 02
Diagnostics
Copyright © 2005 INVENTIO AG 16/16