Sie sind auf Seite 1von 2

KRUGER VENTILATION INDUSTRIES PTE LTD

To: VINCOM JSC


Attn: MR. CONG TRU
Project Name : EDEN HCM

Given Specification Kruger Fan Model

Centrifugal and
Centrifugal Direction Specification
Itm Description Given Selected Model Axial
Required Mounting
fan type Air Flw SP Air Flw SP Specification

L/S Pa L/S Pa Qty CW 90 270 360 Hanger Floor mount


I/ VENTILATION FAN
1.1 B-SPF-R01 QUẠT HƯỚNG TRỤC ( DÙNG VSD) 9800 650 9800 650 1 TDA900-V-14AA-12-12/24
1.2 B-SPF-R02 QUẠT HƯỚNG TRỤC ( DÙNG VSD) 9800 650 9800 650 1 TDA900-V-14AA-12-12/24
1.3 B-SPF-R03 QUẠT HƯỚNG TRỤC ( DÙNG VSD) 9800 650 9800 650 1 TDA900-V-14AA-12-12/24
1.4 B-SPF-R04 QUẠT HƯỚNG TRỤC ( DÙNG VSD) 9800 650 9800 650 1 TDA900-V-14AA-12-12/24
QUẠT HƯỚNG TRỤC ( DÙNG VSD)
1.5 B-SPF-B6-01&02 CHỊU NHIỆT 250ºC, 2HRS 1800 250 1800 250 2 TDA560-F-12AA-8-8/28
QUẠT HƯỚNG TRỤC ( DÙNG VSD)
1.6 B-SPF-B2-01&02 CHỊU NHIỆT 250ºC, 2HRS 520 250 520 250 2 TDA355-F-12AA-5-5/20
1.7 B-OAF-1-01-06 QUẠT LY TÂM CABINET IN-LINE 1180 200 1180 200 6 CCK-KAT 12/12/CL
1.8 B-OAF-M-01-06 QUẠT LY TÂM CABINET IN-LINE 1100 200 1100 200 6 CCK-KAT 12/9/CL
1.9 B-OAF-2-01-04 QUẠT LY TÂM CABINET IN-LINE 1600 250 1600 250 4 CCK-KAT 12/12/CL
1.10 B-OAF-3-01-04 QUẠT LY TÂM CABINET IN-LINE 1600 250 1600 250 4 CCK-KAT 12/12/CL
1.11 B-OAF-4-01-04 QUẠT LY TÂM CABINET IN-LINE 1600 250 1600 250 4 CCK-KAT 12/12/CL
1.12 B-OAF-KT-01-04 QUẠT LY TÂM CABINET IN-LINE 1600 250 1600 250 4 CCK-KAT 12/12/CL
1.13 B-OAF-5-01-04 QUẠT LY TÂM CABINET IN-LINE 1141 200 1141 200 4 CCK-KAT 12/9/CL
1.14 B-OAF-6-01-04 QUẠT LY TÂM CABINET IN-LINE 1141 200 1141 200 4 CCK-KAT 12/9/CL
1.15 B-OAF-7-01-04 QUẠT LY TÂM CABINET IN-LINE 1141 200 1141 200 4 CCK-KAT 12/9/CL
1.16 B-OAF-8-01-04 QUẠT LY TÂM CABINET IN-LINE 1141 200 1141 200 4 CCK-KAT 12/9/CL
1.17 B-OAF-9-01-04 QUẠT LY TÂM CABINET IN-LINE 1141 200 1141 200 4 CCK-KAT 12/9/CL
1.18 B-OAF-10-01-04 QUẠT LY TÂM CABINET IN-LINE 1141 200 1141 200 4 CCK-KAT 12/9/CL
1.19 B-OAF-11-01-04 QUẠT LY TÂM CABINET IN-LINE 1141 200 1141 200 4 CCK-KAT 12/9/CL
1.20 B-OAF-14-01-04 QUẠT LY TÂM CABINET IN-LINE 1141 200 1141 200 4 CCK-KAT 12/9/CL
1.21 B-OAF-(12-13 & 15-21)QUẠT LY TÂM CABINET IN-LINE 1141 200 1141 200 36 CCK-KAT 12/9/CL

(PLEASE TICK THE CELL BY REGARDING TO FAN INSTALLING SPECIFICATION AT SITE)

Page 1 of 1
Frame
The frame is manufactured with galvanized angular bars.
The frame is sheared, bent and spot welded in a way that
ensures correct dimensions and also maximum rigidity.

Shaft
Shafts are manufactured from C45 carbon steel using an
automatic process for positioning and cutting of the
keyways. All dimensional tolerances of the shaft are fully
checked to ensure a precision fit and then coated with an
anti-corrosion varnish after assembly.

Bearings
All bearings used are deep groove ball type sealed at both
sides. The bearings are self-aligning with an eccentric
locking collar for clamping onto the shaft and is mounted in
a rubber housing.
All the bearings are lubricated for life and maintenance-free
under normal operating conditions.

Outlet Flanges
Outlet flanges are accessories that are available upon
request.

Balancing Quality
All wheels are statically and dynamically balanced to
ISO1940 and AMCA 204 – G2.5 standards.
All fans after assembly are trim-balanced to ISO1940 and
AMCA 204 – G2.5 standard.

Fan Rotation and Discharge


The rotation and discharge of the fan is in accordance with AMCA standard 99-2406-83.
The direction of rotation is determined from the drive side of the fan [refer Fig. 2] :-

CW - clockwise rotation
CCW - counter-clockwise rotation

90° 180° 270° 360°

CW

CCW

Fig. 2 - Fan rotation and discharge