Sie sind auf Seite 1von 102

Limit Switches

2.0 Introduction
E47 Precision Switch
Technical Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-2
2
Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-3
2
2.1 E47 Precision Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-6
2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-7
2
2.2 Compact Prewired Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-15
2
Compact Prewired Switch
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-16
2
2.3 LS-Titan Miniature DIN Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-21
2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-23
2
2.4 E49 Mini Metal Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-43
2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-44
2
2.5 E49 Compact Metal Switches
2
LS-Titan Miniature DIN Switch
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-49
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-50
2
2.6 E50 Heavy-Duty Plug-In Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-54 2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-55
2
2.7 E50 Heavy-Duty Factory Sealed 6P+ Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-68 2
E49 Compact Metal Switch
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-69
2
2.8 Operators
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-80 2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-81
2
2.9 Non Plug-In Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-89 2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-90
2
2.10 Hazardous Location Limit Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-92 2
Heavy-Duty Factory Sealed
6P+ Switch
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-93
2
2.11 Special Purpose Limit Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-96 2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-97
2
Unless otherwise noted, the products contained in this section should not
be used for functional safety applications. These products were not designed 2
or tested to IEC 60947-5-3 or recommended for functional safety.
2
Learn
Online
2
2
For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
2
For Application Assistance in the U.S. and Canada
call 1-800-426-9184. 2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-1


2.0 Limit Switches
Introduction

Technical Reference
2
Limit Switches
2
2
2
2
2
2
2
2
2
2 Mechanical Limit Switches
are contact sensors widely
Limit Switches offer high
precision in terms of accuracy
Limit switches contain the
following major components.
used for detecting the and repeatability. This is These may be modular or part
2 presence or position of primarily due to the fact that of a single-piece switch.
objects in industrial they make direct contact
2 applications. with the target. When an Limit Switch Components
object contacts the limit
2 switch lever (or plunger)
the lever moves a pre-travel
Actuator/
Operating Switch
Head Body
2
distance to the operating Actuator/
point where the contacts are Operating
tripped. Movement of the Head
2 lever beyond this point is
called the over-travel.
2 Lever Type Actuator
Pre-travel
2 Initial Position Operating
Point Over-travel
2
2 Receptacle/
Reset Point
2 Switch
Terminals

Body
2 Differential

2 Actuator Terminals
This is the part of the switch The terminals are the point of
2 that contacts the target.
Typical actuators are levers
connection for the wiring.
These terminals may be on
Initial Position

2 Pre-travel
Reset Point
and plungers. Several styles
are available, see Sensor
the body itself, or housed in a
removable receptacle. The
Differential Learning Course, Page limit switch may also come
2 Over-travel
Operating Point
Final Position
V8-T12-4, for more equipped with a factory
information. installed cable or pin-
2 Switch Body
connector.

2 This part contains the


electrical contact mechanism.
Refer to Sensor Learning Course, Page V8-T12-4, for a
For complete information on
2 complete description of limit switch terminology.
electrical outputs, see Sensor
Learning Course, Page
2 V8-T12-4.

V8-T2-2 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Introduction
2.0
Product Selection Guide
2
E47 Precision Switches
Compact Prewired
Switches
LS-Titan Miniature
DIN Switches E49 Mini Metal Switches 2
2
2
2
2
Page V8-T2-6 Page V8-T2-15 Page V8-T2-21 Page V8-T2-43
2
Overview Overview Overview Overview 2
Specified when accurate repeatability,
choice of operating forces and travel
Designed to be a versatile, slim device for
hard to fit applications where sealing
Safety position switches with
insulated plastic or rugged metal
Suitable for OEMs who require a small,
cost-effective solution but cannot sacrifice 2
characteristics and tightly controlled integrity is required. enclosures. Approved for worldwide durability and mechanical life as they would
action of cam or target in space restricted
areas are of prime importance. Cost
safety application. if they chose a plastic IEC style switch. 2
effective and compact.

Applications Applications Applications Applications


2
Overhead, folding and elevator doors, Machine tool, food processing and Automatic vending machines, electronic Automatic vending machines, electronic 2
sliding gates, automated guided vehicles packaging assembly machines, elevators and lifts, assembly machines, elevators and lifts,
and commercial instrumentation injection molding, packaging and safety
applications
injection molding, packaging
2
Product Features Product Features Product Features Product Features
2
Self-contained switches or with an enclosed Rugged aluminum alloy die cast housing Modular plug-in head and body components Pre-wired units with custom cable lengths
cast housing for increased durability and
conduit connection
Sealed construction with enclosure ratings Positive opening NC contacts for safety available for high volume customers 2
of NEMA 4, 6 and 13 applications “Fingerproof” terminals protect against
(1/2 in NPT)
High current capacity for power load
Prewired with 3m of 18 AWG, AWM 2517,
300V cable
Operating heads can be rotated 90 degrees
to suit specific direction of operation
accidental shock
Double-spring mechanism for contact
2
switching and motor handling capability reliability
Screw and solder terminations
Stackable ridge for ganged operation
Grounding terminal included 2
Booted enclosed version shields actuators
2
Captive screws on enclosure cover make
from debris wiring hassle-free
Mounting centers—1.0 in (25.4 mm), SPDT double break
#8 screw size
2
Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications

Mechanical life: 3,000,000 operations min. Mechanical life: 10,000,000 operations Mechanical life: 8,000,000 operations Contact ratings— 2
min. 5A at 250 Vac
2
Electrical life: 500,000 operations min. Contact ratings—
Electrical life: 200,000 operations AC-15, 6A at 24V, 6A at 230/240V, 5A at 30 Vdc
Contact ratings—
NEMA A600, R300, AC-15, DC-13 30 operations min. 4A at 400/415V; Enclosure ratings—
15A/20A, 125 or 250 Vac Contact ratings—
NEMA B300
DC-13, 3A at 24V, 800 mA at 110V,
300 mA at 220V
IP65
Construction—
2
Enclosure ratings—
Enclosure ratings— Zinc alloy
Enclosed: NEMA 1
Construction—
Enclosure ratings—
NEMA 4, 6 and 13; IP67, IP69K IP66, IP67 (by model) 2
Construction—
2
Basic: Phenolic Construction—
Enclosed: Aluminum die cast Aluminum alloy die cast Plastic or metal (by model)

Approvals Approvals Approvals Approvals 2


UL® Recognized cULus Safety function, IEC/EN 60947-5-1 UL Recognized
CSA® Certified
CE
TÜV-Rheinland certified (LSE models)
CSA certified
CE 2
2
UL listed
CE
CCC
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-3


2.0 Limit Switches
Introduction

E49 Compact Metal E50 Heavy-Duty Plug-In E50 Heavy-Duty Factory


2 Switches Switches Sealed 6P+ Switches Operators

2
2
2
2
2 Page V8-T2-49 Page V8-T2-54 Page V8-T2-68 Page V8-T2-80

2 Overview Overview Overview Overview

2 Designed with high mechanical strength for


robust environments. The rugged Aluminum
Versatile in design. High reliability. Low
maintenance costs with installation ease.
Designed specifically to withstand the
penetrating properties of new cutting fluids
Wide variety of operator types for rotary and
wobble style limit switches.
die cast construction provides reliable, oil- BEST CHOICE for Heavy-Duty Limit Switch (coolants), acid or caustic washes, salt
2 tight, waterproof and dustproof sealing for
a variety of applications. Snap action 1NO-
applications. Withstands physical and
chemical abuse of harsh industrial
spray, severe vibration, shock and
temperature fluctuations, grit and debris.
1NC contacts provide flexibility in design. environments.
2 Applications Applications Applications Applications

2 Packaging, material handling conveyors,


end-of-travel and guarding operations,
Punch presses, waste water treatment,
machine tool, automotive, retrieval
Automotive, pulp and paper, food
processing, waste management, primary
Used with E50, E50 6P+ and 10316
limit switches

2
baler/compactor, industrial door lifts systems, industrial truck, car wash lines metals, machine tool (cutting, forming,
bending)

2 Product Features Product Features Product Features Product Features

Rigid die cast switch housing Modular operating heads, switch bodies Tamperproof, one-piece switch body Rollers and rods available in metal
2 Set position indicator plate for easy
maintenance
and receptacles are interchangeable
without field adjustment
assembly, epoxy filled
Factory sealed. 6P submersible. Pre-wired
and nonmetal contact surfaces

2 High mechanical strength Order as complete assemblies or with cable, pigtail or pin connector options.
components for stocking and All with ground connection
Oiltight, waterproof and dustproof manufacturing flexibility Utilizes E50 modular operating heads
2 construction
90 degree total travel, 5 degree pre-travel
characteristics are standard features
Special V-seal on switch body/head
connection provides hermetic barrier
2 Viton® gasket, boot, and seal material
offers exceptional chemical resistance
against fluid ingress
LED indicating light, 24V–120 Vac/dc

2 Rotary head operating mode from CW,


CCW or CW and CCW is easily changed
neon version too
Peel off see-through painting mask over
without tools nameplate
2
Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications
2 Mechanical life: 15,000,000 operations Mechanical life: 13,000,000 operations Mechanical life: 35,000,000 operations min. Varies by model
min. min.
2
Electrical life: 1,000,000 operations
Electrical life: 500,000 operations Electrical life: 1,000,000 operations min. at full load
min. at full load min. at full load (single-pole) Contact ratings—
2 Contact ratings—
NEMA A600, R300; AC-15, DC-13
Contact ratings—
NEMA A600, R300
NEMA A600, R300
Lighted versions A150, R150

2 Enclosure ratings— Lighted versions A150, R150 6A, 120 Vac; 10A continuous
NEMA 4, 4X, 6, 6P, 12, 13; IP65, IP67 6A, 120 Vac; 10A continuous Enclosure ratings—
Enclosure ratings— NEMA 1, 2, 3, 3S, 4, 4X, 6, 6P, 13; IP67,
2
Construction—
Aluminum die cast NEMA 1, 3, 3S, 4, 4X, 6, 6P, 13; IP67 IP69K
Construction—Zinc die cast Construction—Zinc die cast
2 Approvals Approvals Approvals Approvals

2 cULus
IP67
UL Listed
CSA Certified
UL Listed
CSA Certified
Varies by model

2
IEC 947-5-1 IEC 947-5-1
TUV TUV
CE (some models) CE (some models)
2
2
2

V8-T2-4 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Introduction
2.0
Hazardous Location
Non Plug-In Switches Switches Special Purpose Switches 2
2
2
2
2
Page V8-T2-89 Page V8-T2-92 Page V8-T2-96
2
Overview Overview Overview 2
The Industrial standard for Non Plug-In
Heavy-Duty Limit Switches. Sold as
Designed for severe environmental service
in locations where there exists a danger of
Variety of special function limit switch
products. 2
complete assembled units only. an internal or external explosion of
flammable gases, vapors, metal alloy or
grain dust.
2
Applications Applications Applications
2
Serving MRO and USER replacement
requirements with broad
Mining, metal cutting, grain storage, forest
products, petrochemical, waste and sewage
Serving MRO and USER replacement
requirements with broad market coverage
2
2
d market coverage management, pharmaceutical

Product Features Product Features Product Features


2
Side and top rotary, side and top push or Sealed and unsealed versions available Special function switch lines include:
wobble operation
CW, CCW or CW and CCW operating modes
One-way gasket on sealed version keeps
liquids out, yet allows a harmless release of
Cabinet door interlocks — when plunger
is pulled out, red band indicator visually
2
2
are field convertible gases in the event of an internal explosion shows that interlock is defeated
Double break-make snap action contacts, Silicon bronze housing provides excellent Precision switches—1NO-1NC,
same polarity each pole corrosion resistant properties in extreme 2NO-2NC, or operator only. Variety of
Captive saddle clamp terminals accept up NEMA 4X applications mounting brackets available 2
to #12 wire Temperature build-up on limit switch Pneumatic time delay—ON delay and OFF
Head can be mounted in any of four discrete
positions, intervals of 90 degrees
surface is dissipated by housing design and
materials used
delay. Timing range—0.05 to 60 seconds
Rotating cam shaft switches
2
2
Utilizes the operating heads and internal
switch mechanisms of the 10316
Non Plug-In line
2
Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications

Mechanical life: 10,000,000 operations NEMA 7, Div. 1, Class I, BCD See Page V8-T2-99 for more information 2
min. NEMA 9, Div. 1, Class II, EFG Enclosure ratings—
Electrical life: 500,000 operations at Contact ratings—NEMA B600 NEMA 1 or NEMA 4 versions 2
full load 3A, 120 Vac; 5A continuous Construction—
Contact ratings—NEMA A600, R300
6A, 120 Vac; 10A continuous
Enclosure ratings—LX: NEMA 7, 9 Zinc die cast
PS: Phenolic
2
CX: NEMA 1, 4, 7, 9
Enclosure ratings—NEMA 1, 4, 13
Construction—
CB: NEMA 1, 4, 4X, 13
CBX: NEMA 1, 4, 4X, 7, 9, 13 2
2
Zinc die cast Construction—LX, CX: Aluminum die cast
CB, CBX: Silicon bronze

Approvals Approvals Approvals


2
UL Listed
CSA Certified
cUL® Listed UL Listed
CSA Certified (PS and J only)
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-5


2.1 Limit Switches
E47 Precision Switches

Contents
2 E47 Precision Switches
Description Page
2 E47 Precision Switches
Product Selection
2 Basic Switches . . . . . . . . . . . . . . . . . . . . . . V8-T2-7
Enclosed Switches. . . . . . . . . . . . . . . . . . . . V8-T2-9
2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-10
Technical Data and Specifications . . . . . . . . . . V8-T2-10
2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-12

2 Drawings
Online

2
2
2
2
2 E47 Precision Switches
2 Product Description Features Operating Characteristics Standards and Certifications
E47 Precision Switches from ● Compact housings are ● UL Recognized
2
Definitions
Eaton’s electrical sector ideal for use where space ● CSA Certified
provide high accuracy is restricted ● CE
2 switching at an affordable
price. A variety of standard
● Precision, snap-action ● RoHS
operators provide accurate
2 features, such as current
capacity, operating force,
repeatability of electrical
and mechanical operating
travel characteristics and characteristics
2 actuators, lets you custom ● High current capacity
fit the switch to your (up to 20A) allows power
2 application. load switching and motor
The switches are available handling capability DANGER
2 in their compact basic form, ● Enclosed booted versions THIS SENSOR IS NOT A
or enclosed in a rugged, shield actuators from OF—Operating Force SAFETY DEVICE AND IS NOT
2

metal housing. debris INTENDED TO BE USED AS A
● RF—Return Force
SAFETY DEVICE. This sensor
2 PT—Pre-Travel

is designed only to detect
● OT—Over-Travel and read certain data in an
2 ● MD—Movement
Differential
electronic manner and
perform no use apart from
2
● FP—Free Position that, specifically no safety-
● OP—Operating Position related use. This sensor
product does not include
2 self-checking redundant
circuitry, and the failure of
2 this sensor product could
cause either an energized
2 or de-energized output
condition, which could result
in death, serious bodily
2 injury, or property damage.

2
2
2 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
For the most current information
2 on this product, visit our Web site:
www.eaton.com
For Application Assistance in the U.S. and Canada
call 1-800-426-9184.

V8-T2-6 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E47 Precision Switches
2.1
Product Selection
2
Basic Switches
2
E47 Precision Switches—Basic
15A 20A 2
Type Specifications 1 Catalog Number Catalog Number
Pin Plunger Pin Plunger 2
2
Screw terminal OF max.—12.3 oz (350g) E47BMS01 E47CMS01
RF max.—4.02 oz (114g)
PT max.—0.016 in (0.4 mm)
Solder terminal OT max.—0.005 in (0.13 mm)
MD max.—0.002 in (0.05 mm)
E47BML01 E47CML01 2 2
OP—0.626 in (15.9 mm)
Extended Plunger Extended Plunger 2
2
Screw terminal OF max.—12.3 oz (350g) E47BMS03 —
RF max.—4.02 oz (114g)
PT max.—0.016 in (0.4 mm)
Solder terminal
OT max.—0.063 in (1.6 mm)
MD max.—0.002 in (0.05 mm)
E47BML03 — 2
OP—1.11 in (28.2 mm)

Straight Plunger Straight Plunger


2
Screw terminal OF max.—12.3 oz (350g)
RF max.—4.02 oz (114g)
E47BMS02 E47CMS02
2
PT max.—0.016 in (0.4 mm)
Solder terminal
OT max.—0.063 in (1.6 mm)
MD max.—0.002 in (0.05 mm)
E47BML02 E47CML02 2
2
OP—0.846 in (21.5 mm)

Reversed Lever Reversed Lever


Screw terminal OF max.—5.29 oz (150g)
RF max.—0.49 oz (14g)
E47BMS21 — 2
2
PT max.—0.16 in (4 mm)
Solder terminal OT max.—0.063 in (1.6 mm) E47BML21 —
MD max.—0.051 in (1.3 mm)
Spade terminal
FP max.—0.81 in (20.6 mm)
OP—0.685 in (17.4 mm) E47BMT21 — 2
Straight Lever Straight Lever 2
2
Screw terminal OF max.—2.47 oz (70g) E47BMS22 E47CMS22
RF min.—0.49 oz (14g)
PT max.—0.394 in (10 mm)

Solder terminal
OT max.—0.220 in (5.6 mm)
MD max.—0.051 in (1.3 mm) E47BML22 — 2
FP max.—1.11 in (28.2 mm)
OP—0.748 in (19 mm) 2
Standard Lever Standard Lever
Screw terminal OF max.—3.53 oz (100g) E47BMS20 — 2
RF min.—0.99 oz (28g)
PT max.—0.197 in (5.0 mm)
OT max.—0.079 in (2.0 mm)
2
Solder terminal MD max.—0.039 in (1.0 mm) E47BML20 —
FP max.—0.976 in (24.8 mm) 2
OP—0.748 in (19 mm)

Extended Straight Extended Straight Plunger 2


Plunger
Screw terminal OF max.—12.3 oz (350g) E47BMS04 E47CMS04
RF max.—4.02 oz (114g) 2
PT max.—0.016 in (0.4 mm)
Screw terminal (with space lugs) OT max.—0.217 in (5.5 mm)
MD max.—0.002 in (0.05 mm)
E47BMT04 —
2
OP—0.858 in (21.8 mm)
Solder terminal E47BML04 E47CML04 2
Notes
2
2
1 OF = Operating Force; RF = Return Force; PT = Pre-Travel; OT = Over-Travel; MD = Movement Differential;

FP = Free Position; OP = Operating Position.


2 Contact Eaton’s Sensor Applications Department at 1-800-426-9184 for approval status.

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-7


2.1 Limit Switches
E47 Precision Switches

E47 Precision Switches—Basic, continued


2 15A 20A
Type Specifications 1 Catalog Number Catalog Number
2 Roller Plunger Roller Plunger

2 Screw terminal OF max.—12.3 oz (350g)


RF max.—4.02 oz (114g)
E47BMS10 E47CMS10

PT max.—0.016 in (0.4 mm)


2 OT max.—0.14 in (3.6 mm)
MD max.—0.002 in (0.05 mm)
Solder terminal E47BML10 —
2
OP—1.315 in (33.4 mm)

2
Cross Roller Plunger Cross Roller Plunger

2 Screw terminal OF max.—12.3 oz (350g)


RF max.—4.02 oz (114g)
E47BMS11 E47CMS11

2
PT max.—0.016 in (0.4 mm)
OT max.—0.14 in (3.6 mm)
MD max.—0.002 in (0.05 mm)
2 Solder terminal OP—1.315 in (33.4 mm) E47BML11 —

2
Reversed Roller Lever Reversed Roller Lever
2 Screw terminal OF max.—5.29 oz (150g) E47BMS41 —
RF max.—0.49 oz (14g)
2 PT max.—0.16 in (4 mm)
OT max.—0.063 in (1.6 mm)
Solder terminal MD max.—0.051 in (1.3 mm) E47BML41 —
2 FP max.—1.252 in (31.8 mm)
OP—1.126 in (28.6 mm)

2 Extended Roller Lever Extended Roller Lever


Screw terminal OF max.—5.64 oz (160g) E47BMS42 E47CMS42
2 RF min.—0.78 oz (22g)
PT max.—0.28 in (7.1 mm)
OT max.—0.16 in (4 mm)
2 Solder terminal MD max.—0.04 in (1.02 mm)
FP max.—1.437 in (36.5 mm)
E47BML42 —

2
OP—1.189 in (30.2 mm)
Roller Lever Roller Lever

2 Screw terminal OF max.—5.64 oz (160g)


RF min.—1.48 oz (42g)
E47BMS30 E47CMS30

PT max.—0.106 in (2.7 mm)


2 Solder terminal
OT max.—0.094 in (2.4 mm)
MD max.—0.02 in (0.5 mm)
E47BML30 —

2 Spade terminal FP max.—1.28 in (32.5 mm) E47BMT30 E47CMT30


OP—1.189 in (30.2 mm)

2
One-Way Roller One-Way Roller
Screw terminal OF max.—5.64 oz (160g) E47BMS31 —
RF min.—1.48 oz (42g)
2 PT max.—0.106 in (2.7 mm)
OT max.—0.094 in (2.4 mm)

2 Solder terminal
MD max.—0.02 in (0.5 mm)
FP—1.717 in (43.6 mm) E47BML31 —
OP—1.697 in (43.1 mm)
2
2 Integral Leaf Integral Leaf
Screw terminal OF max.—0.35 oz (10g) E47BMS23 E47CMS23
2 RF min.—0.106 oz (3.0g)
PT max.—0.787 in (20.0 mm)
Solder terminal OT max.—0.22 in (5.6 mm) E47BML23 —
2 MD max.—0.118 in (3.0 mm)
OP—0.748 in (19.0 mm)

2 Note
1 OF = Operating Force; RF = Return Force; PT = Pre-Travel; OT = Over-Travel; MD = Movement Differential;

2 FP = Free Position; OP = Operating Position.

V8-T2-8 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E47 Precision Switches
2.1
E47 Precision Switches—Basic, continued
15A 20A
2
Type Specifications 1 Catalog Number Catalog Number
Adjustable Roller Adjustable Roller
2
Screw terminal OF max.—17.64 oz (500g)
RF min.—6.0 oz (170g)
E47BMS40 —
2
PT max.—0.197 in (5.0 mm)
OT max.—0.5 in (12.7 mm)
MD max.—0.087 in (2.2 mm)
2
Solder terminal E47BML40 —
2
FP max.—1.752 in (44.5 mm)
OP—1.591 in (40.4 mm)

Extended
Adjustable Roller
Extended Adjustable Roller 2
Screw terminal OF max.—21.16 oz (600g) E47BMS43 —
RF min.—10.58 oz (300g)
PT max.—0.118 in (3.0 mm)
2
Solder terminal
OT max.—0.236 in (6.0 mm)
MD max.—0.079 in (2.0 mm)
E47BML43 —
2
FP max.—1.614 in (41 mm)
OP—1.591 in (40.4 mm)
2
2
Enclosed Switches 2
E47 Precision Switches—Enclosed 2
Specifications 1 Catalog Number Specifications 1 Catalog Number

Plunger Actuator Plunger Actuator Booted Roller Lever Booted Roller Lever 2
2
OF max.—8.82–12.3 oz (250–350g) E47BLS05 OF max.—22.57 oz (640g) E47BLS33
RF min.—4.02 oz (114g) RF min.—8.11 oz (230g)
PT max.—0.016 in (0.4 mm) PT max.—0.197 in (5.0 mm)
OT max.—0.217 in (5.5 mm)
MD max.—0.002 in (0.05 mm) E47CLS05 23
OT max.—0.236 in (6.0 mm)
MD max.—0.016 in (0.4 mm) 2
OP—1.504 in (38.2 mm)
2
Booted Plunger Booted Plunger
Roller Plunger Roller Plunger
2
OF max.—28.22 oz (800g) E47BLS06
RF min.—8.46 oz (240g)
PT max.—0.079 in (2.0 mm)
OF max.—8.82–12.3 oz (250–350g)
RF min.—4.02 oz (114g)
E47BLS07
2
OT max.—0.197 in (5.0 mm) PT max.—0.02 in (0.5 mm)
MD max.—0.004 in (0.1 mm)
OP—1.803 in (45.8 mm)
E47CLS06 23 OT max.—0.142 in (3.6 mm)
MD max.—0.002 in (0.05 mm)
2
E47BLS11 4
2
OP—1.957 in (49.7 mm)

Roller Lever Roller Lever


OF max.—20.1 oz (570g) E47BLS32 Booted Roller Plunger Booted Roller Plunger 2
RF min.—6.0 oz (170g)
PT max.—0.157 in (4.0 mm)
OT max.—0.236 in (6.0 mm)
OF max.—17.64 oz (500g)
RF min.—3.53 oz (100g)
E47BLS08
2
MD max.—0.016 in (0.4 mm) PT max.—0.039 in (1.0 mm)
E47CLS32 23 OT max.—0.138 in (3.5 mm)
MD max.—0.005 in (0.12 mm)
2
E47BLS12 4
OP—1.957 in (49.7 mm)
2
2
Notes
1 OF = Operating Force; RF = Return Force; PT = Pre-Travel; OT = Over-Travel; MD = Movement Differential;

FP = Free Position; OP = Operating Position.


2
2
2 Contact Eaton’s Sensor Applications Department at 1-800-426-9184 for approval status.
3 20 ampere version.
4 Cross roller unit.

2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-9


2.1 Limit Switches
E47 Precision Switches

E47 Precision Switches— E47 Precision Switches—


2 Enclosed, continued Enclosed, continued
Specifications 1 Specifications 1
2
Catalog Number Catalog Number
One-Way Roller One-Way Roller Booted Wobble Booted Wobble

2 OF max.—20.1 oz (570g)
RF min.—6.0 oz (170g)
E47BLS34 OF max.—2.11 oz (60g)
RF min.—0.88 oz (25g)
E47BLS14

PT max.—0.157 in (4.0 mm) PT max.—0.520 in (13.2 mm)


2 OT max.—0.236 in (6.0 mm)
MD max.—0.016 in (0.4 mm)
OT max.—0.315 in (8.0 mm)
MD max.—0.039 in (1.0 mm)

2
2 Booted One-Way Booted One-Way Roller

2
Roller
OF max.—22.57 oz (640g) E47BLS35
RF min.—8.11 oz (230g)

2
PT max.—0.197 in (5.0 mm)
OT max.—0.236 in (6.0 mm)
MD max.—0.016 in (0.4 mm)
2
2
2
2 Accessories
2 Terminal Wire Covers for Basic Switches
2 Description Catalog Number Description Catalog Number
45° Terminal wire cover with E47PA1 90° Terminal wire cover with E47PA2
2 45° conduit interface 90° conduit interface

2
2
2
Technical Data and Specifications
2
E47 Precision Switches
2 Description Specification

2 Operating speed
Operating Frequency
0.01m/second to 1m/second

2 Mechanical 120 operations/minute


Electrical 20 operations/minute
2 Mechanical life 3,000,000 operations minimum
Electrical life 500,000 operations minimum
2 Contact resistance 15M ohms maximum, initial

2 Insulation resistance
Dielectric Strength
100M ohms minimum at 500 Vdc

2 Between non-current carrying parts 1000 Vac, 50/60 Hz for 1 minute


Between current carrying parts and ground 2000 Vac, 50/60 Hz for 1 minute

2 Notes
1 OF = Operating Force; RF = Return Force; PT = Pre-Travel; OT = Over-Travel;

2 MD = Movement Differential; FP = Free Position; OP = Operating Position.


2 Cross roller unit.

2
2

V8-T2-10 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E47 Precision Switches
2.1
E47 Precision Switches, continued
Description Specification
2
Ambient Operating Temperature
Basic –13° to 176°F (–25° to 80°C)
2
Enclosed 5° to 176°F (–15° to 80°C) 2
Environmental rating enclosed, booted NEMA 1
Mounting centers 1.0 in (25.4 mm), #8 screw size 2
2
Terminal screws Bottom facing M4 x 0.7 (8–32)
Screws with cup washers will accept 22–12 AWG (2.5 sq. mm maximum)
Maximum torque: 10 in-lbs.
Threaded bushing 15/32 in 2
Material of construction Mineral filled phenolic
Enclosure rating Aluminum die casting (ADC-3/A380); Seal boot: nitrile, butyl rubber (NBR) 2
2
Conduit fitting on enclosed type 1/2 in NPT

Maximum Ampere Ratings 1 2 2


Non-Inductive Load (A)
Resistive Load Lamp Load
Inductive Load (A)
Inductive Load Motor Load Inrush Current (A)
2
Rated
Model Voltage NC and NO NC NO NC and NO NC NO NC NO
2
15A 125 Vac 15 3 1.5 15 5 2.5 30 max. 15 max.
250 Vac 15 2.5 1.25 15 3 1.5 2
500 Vac 3 1.5 0.75 2.5 1.5 0.75
8 Vdc 15 3 1.5 15 5 2.5 2
2
14 Vdc 15 3 1.5 10 5 2.5
30 Vdc 6 (2) 3 1.5 5 5 2.5
125 Vdc 0.4 0.4 0.4 0.05 0.05 0.05
2
250 Vdc 0.2 0.2 0.2 0.03 0.03 0.03
20A 125 Vac 20 7.5 7.5 20 12.5 12.5 60 max. 30 max. 2
250 Vac 20 7.5 7.5 20 8.3 8.3
500 Vac 6 4 4 5 2 2 2
8 Vdc
14 Vdc
20
20
3
3
1.5
1.5
20
15
12.5
12.5
12.5
12.5
2
30 Vdc 6 3 1.5 5 5 5 2
125 Vdc 0.5 0.5 0.5 0.05 0.05 0.05
250 Vdc 0.25 0.25 0.25 0.03 0.03 0.03 2
Terminal Configurations
2
Screw Type Solder Type 2
2
2
2
Contact Configuration—
Form C Precision Snap Action
2
(Spade type not shown, available on some models) 2
Notes
1 Inductive load has a power factor of 0.04 minimum (AC) and a time constant of 7 m/second (DC).
2
2
2 Lamp load has an inrush current of six times steady-state current.

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-11


2.1 Limit Switches
E47 Precision Switches

Dimensions
2 Approximate Dimensions in Inches [mm]

2 Basic Switches

2 Pin Plunger Standard Lever

2
2
2
2
2
Extended Plunger Extended Straight Plunger
2
2
2
2
2
Straight Plunger Roller Plunger
2
2
2
2
2
2 Reversed Lever Cross Roller Plunger

2
2
2
2
2 Straight Lever Reversed Roller Lever

2
2
2
2
2
2

V8-T2-12 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E47 Precision Switches
2.1
Approximate Dimensions in Inches [mm]
2
Extended Roller Lever Integral Leaf
2
2
2
2
Roller Lever Adjustable Roller 2
2
2
2
2
2
One-Way Roller Extended Adjustable Roller
2
2
2
2
2
2
Enclosed Switches
Plunger Actuator Roller Lever 2
2
2
2
2
2
2
Booted Plunger Booted Roller Lever
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-13


2.1 Limit Switches
E47 Precision Switches

Approximate Dimensions in Inches [mm]


2
Roller Plunger Booted One-Way Roller
2
2
2
2
2
2
2 Booted Roller Plunger Booted Wobble

2 0.25 [6.5]
Dia.
PT
5.91
[150]

2
0.37 3.37
[9.5] [85.5]
0.67
[17] 0.08

2
2-M4.0 x 45 [2.1]

0.91 1.00

2 [23] [25.5]
1.00 [25.4] 1.00 [25.4] 0.96 [24.5]

2 One-Way Roller
2
2
2
2
2
2
Accessories
2 Approximate Dimensions in mm

2 Terminal Wire Cover with 45° Conduit Interface Terminal Wire Cover with 90° Conduit Interface

2 21 53 53
2-ø4.2 21 2-ø4.2
25.4 25.4

2
14

14

7
7

21
21

2
39
46

2
18

A A
25

12 B B
2 14
12
14
12
2
2
2
2

V8-T2-14 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Compact Prewired Switches
2.2
Contents
Compact Prewired Switches
Description Page
2
Compact Prewired Switches 2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V8-T2-16
Technical Data and Specifications . . . . . . . . . . V8-T2-18 2
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-18
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-19 2
Drawings
Online 2
2
2
2
2
2
Compact Prewired Switches 2
Product Description Features Standards and Certifications
DANGER
2
The E47 Compact Prewired ● Rugged aluminum alloy die ● cULus (cable versions only)
Limit Switch by Eaton’s cast housing ● UL (cable versions only) THIS SENSOR IS NOT A
SAFETY DEVICE AND IS NOT
2
electrical sector is designed ● Sealed construction with ● NEMA 4, 6 and 13
to be a versatile, slim device
for hard to fit applications
enclosure ratings of NEMA ● IEC IP67, IP69K
INTENDED TO BE USED AS A
SAFETY DEVICE. This sensor 2
4, 6 and 13
● RoHS is designed only to detect
where sealing integrity is
required. The rugged die
● Prewired with 3m of
18 AWG, AWM 2517,
and read certain data in an 2
cast aluminum alloy housing, electronic manner and
cable connection and switch
300V cable, or micro
connector version also
perform no use apart from 2
mechanism are encapsulated that, specifically no safety-
available
for protection against extreme
temperature (–10° to 70°C
● Stackable ridge for ganged
related use. This sensor
product does not include
2
operation
[14° to 158°F]), contaminants,
moisture, shock and
self-checking redundant
circuitry, and the failure of 2
vibration. This factory wired this sensor product could
(3m) device has NEMA® cause either an energized 2
enclosure ratings of 4, 6 or de-energized output
and 13, making it suitable condition, which could result 2
for applications such as in death, serious bodily
machine tool, food
processing and packaging.
injury, or property damage.
2
2
2
2
2
2
2
2
For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
2
For the most current information
on this product, visit our Web site:
www.eaton.com
For Application Assistance in the U.S. and Canada
call 1-800-426-9184. 2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-15


2.2 Limit Switches
Compact Prewired Switches

Product Selection
2
2
Compact Prewired Switches
Movement

2
Operating Force Reset Force Over-Travel Differential Operating Standard Version Connector Version
Actuator Type (Maximum) (Minimum) (Maximum) Pre-Travel (Maximum) Position Catalog Number Catalog Number
Pin Plunger Pin Plunger
2 42.3 oz 15.9 oz 0.118 in 0.07 in 0.008 in 0.62 ± 0.04 in E47BCC05 E47BCC05P4
(1.2 kg) (450g) (3 mm) (1.8 mm) (0.2 mm) (15.7 ± 1 mm)
2
2
2 Sealed Plunger Sealed Plunger
63.5 oz 15.9 oz 0.118 in 0.07 in 0.008 in 0.99 ± 0.04 in E47BCC06 E47BCC06P4
2 (1.8 kg) (450g) (3 mm) (1.8 mm) (0.2 mm) (24.9 ± 1 mm)

2
2 Roller Plunger Roller Plunger

2 42.3 oz
(1.2 kg)
15.9 oz
(450g)
0.118 in
(3 mm)
0.07 in
(1.8 mm)
0.008 in
(0.2 mm)
1.12 ± 0.04 in
(28.5 ± 1 mm)
E47BCC07 E47BCC07P4

2
2
2 Sealed Roller Plunger Sealed Roller Plunger
63.5 oz 15.9 oz 0.118 in 0.07 in 0.008 in 1.35 ± 0.04 in E47BCC08 E47BCC08P4
2 (1.8 kg) (450g) (3 mm) (1.8 mm) (0.2 mm) (34.3 ± 1 mm)

2
2 Cross Roller Plunger Cross Roller Plunger

2 42.3 oz
(1.2 kg)
15.9 oz
(450g)
0.118 in
(3 mm)
0.07 in
(1.8 mm)
0.008 in
(0.2 mm)
1.12 ± 0.04 in
(28.5 ± 1 mm)
E47BCC11 E47BCC11P4

2
2
2 Sealed Cross Roller
Plunger
Sealed Cross Roller Plunger
63.5 oz 15.9 oz 0.118 in 0.07 in 0.008 in 1.35 ± 0.04 in E47BCC12 E47BCC12P4
2 (1.8 kg) (450g) (3 mm) (1.8 mm) (0.2 mm) (34.3 ± 1 mm)

2
2
2
Bevel Plunger Bevel Plunger
42.3 oz 15.9 oz 0.118 in 0.07 in 0.008 in 1.12 ± 0.04 in E47BCC13 E47BCC13P4

2
(1.2 kg) (450g) (3 mm) (1.8 mm) (0.2 mm) (28.5 ± 1 mm)

2
2
2
2

V8-T2-16 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Compact Prewired Switches
2.2
Compact Prewired Switches, continued
Movement
2
Operating Force Reset Force Over-Travel Differential Operating Standard Version Connector Version
Actuator Type (Maximum) (Minimum) (Maximum) Pre-Travel (Maximum) Position Catalog Number Catalog Number 2
Roller Lever Roller Lever
20.5 oz 5.3 oz 40° 25° max. 3° — E47BCC15 E47BCC15P4 2
(580g) (150g)
2
2
2
Wobble Stick Wobble Stick
5.3 oz — — 15° max. — — E47BCC20 E47BCC20P4 2
(150g)
2
2
2
2
Rod Lever Rod Lever
20.5 oz 5.3 oz 40° 25° max. 3° — — E47BCC21P4 2
(580g) (150g)

2
2
2
Adjustable Level Arm Adjustable Level Arm
20.5 oz 5.3 oz 40° 25° max. 3° — E47BCC22 E47BCC22P4 2
(580g) (150g)
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-17


2.2 Limit Switches
Compact Prewired Switches

Technical Data and Specifications


2
Compact Prewired Switches
2 Description Specification

2 Contacts
Mechanical life
1-SPDT (Form C)
10,000,000 operations

2 Electrical life 200,000 operations, 30 operation/min. at rated load


Operating speed 30 operations per minute maximum
2 Operating temperature range –10° to 70°C (14° to 158°F)

2
Storage temperature range –10° to 70°C (14° to 158°F)
Humidity 95% maximum non-condensing

2 Vibration Malfunction durability, 10 to 55 Hz 1.5 mm double amplitude


Shock Malfunction durability, approximately 50G
2 Enclosure ratings NEMA 4, 6 and 13; IEC IP67

2
Maximum Ampere Ratings 1
2 Non-Inductive Load (A) Inductive Load (A)
Resistive Load Inductive Load Motor Load Inrush Current (A)
2
Rated
Voltage NC NO NC NO NC NO NC NO

2
125 Vac 5 5 3 3 2.5 1.3 20 max. 10 max.
250 Vac 5 5 2 2 1.5 0.8

2 8 Vdc 5 5 5 4 1.5 1.5


14 Vdc 5 5 4 4 1.5 1.5
2 30 Vdc 4 4 3 3 1.5 1.5
125 Vdc 0.4 0.4 0.4 0.4 0.05 0.05
2 250 Vdc 0.2 0.2 0.2 0.2 0.03 0.03

2
Wiring Diagram
2
Compact Prewired Switches Micro Connector Switches
2 NC (Red) Contacts Rated

2
1.0A at 124 Vac
1.0A at 30 Vdc 2 1
2 NC
2 NO (Blue) COM 1 4 NO
Ground
2
Common 3 3 4
(Black) (Green)
Face View of Male Connector

2
Note
2 1 Inductive load ratings are tested at a power factor 0.4 min. for AC power and a time constant of 7 ms max. for DC power. Inrush current for

motor load is six times the steady state current.

2
2
2
2
2
2
2

V8-T2-18 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Compact Prewired Switches
2.2
Dimensions
Approximate Dimensions in mm [in] 2
E47BCC05 E47BCC11 2
2 x Ø10.2 2 x Ø5.1 [Ø0.201] 40.0 [1.575] 16.0
2
25.0 2 x Ø5.1 [Ø0.201]
[0.402] Ø10 [0.397] [0.984] Max [0.630]
Depth: 6 40.0 [1.575] Max
25.0 Stainless 2 x Ø10.2 [0.402]
[0.236] Steel Plunger Depth: 6 [0.236]
[0.984]
PT
4.5 [0.177]
16.0
[0.630]
Max OP
PT
7.0
[0.276]
Ø12.7 [0.500]
x 3.8 [0.150]
Stainless 2.8
2
OP Steel Roller
2
7.5 [0.295] [0.110]
2.8 7.5 [0.295] Correct
8.0 [0.315] [0.110] Setting
54.2 Correct 67.0 8.0 [0.315]
[2.638] Position
[2.134] Setting
Max 49.0
[1.929]
2.0 23.0
[0.079] [0.906]
Postion Max
51.5
[2.028]
23.0
2.0 [0.906]
[0.079]
2
2.0 [0.079]
1.4 1.5
2.0 [0.079] 1.4
1.5
[0.059] 2
34.0 [1.339] [0.055] [0.059] 34.0 [1.339] [0.055]

2
E47BCC06 E47BCC12 2
25.0 40.0 [1.575] 25.0 40.0 [1.575]
2
2 x Ø5.1 [Ø0.201] 2 x Ø5.1 [Ø0.201] 16.0
[0.984] [0.984] [0.630]
2 x Ø10.2 [0.402] 2 x Ø10.2 [0.402] Max
Depth: 6 [0.236] 16.0 Depth: 6 [0.236]
[0.630]
PT
OP
4.0
[0.157]
Ø10 [0.397]
Stainless
Steel Plunger
Max PT
OP
4.0
[0.157]
Ø12.7 [0.500] x
3.8 [0.150]
Stainless Steel
2
Roller Rubber
Rubber
2
7.5 [0.295] Cap
63.5 Cap 73.0 7.5 [0.295]
8.0 [0.315] [2.874]
[2.5] 49.0 8.0 [0.315]
Max. [1.929] Max.
23.0
2.0 [0.906]
[0.079]
49.0
[1.929]
23.0
2.0 [0.906]
[0.079]
2
2.0
[0.079] 1.4 1.5 2.0 1.4
1.5
[0.059]
2
34.0 [1.339] [0.055] [0.059] [0.079] 34.0 [1.339] [0.055]

2
E47BCC07 E47BCC13
2
25.0 40.0 [1.575] 16.0 40.0 [1.575] 16.0

2
Max 2 x Ø5.1 [Ø0.201] 25.0 2 x Ø5.1 [Ø0.201] [0.630]
[0.984] [0.630] [0.984]
2 x Ø10.2 [0.402] Max 2 x Ø10.2 [0.402]
Depth: 6 [0.236] Depth: 6 [0.236]

2
7.0 Ø12.7 [0.500] x 7.0
PT [0.276] 3.8 [0.150] Ø10 [0.397]
2.8 PT [0.276] Stainless
OP Stainless Steel [0.110] OP Steel PLU
Roller Correct 2.8

2
7.5 [0.295] Setting 7.5 [0.295] [0.110]
Position Correct
67.0 8.0 [0.315] 67.0 8.0 [0.315] Setting
[2.638] [2.638] Position
Max
2
51.5 23.0 Max 23.0
[2.028] 2.0 [0.906] 51.5 2.0 [0.906]
[0.079] [2.028] [0.079]

2.0 [0.079] 1.4 1.5 2.0 [0.079] 1.4


1.5
[0.059] 2
34.0 [1.339] [0.055] [0.059] 34.0 [1.339] [0.055]

2
E47BCC08 E47BCC15
2
40.0 [1.575] 50.0 [1.969]

2
25.0 Max 2 x Ø5.1 [Ø0.201] Ø17.0 [0.669] Max.
44.0
[0.984] 2 x Ø10.2 [0.402] x 7.0 [0.276] 25.0 [1.732]
Depth: 6 [0.236] 16.0 Stainless [0.984]
[0.630] Sintered Roller
2
4.0 Ø12.7 [0.500] x 31.5
PT Max R38 [1.240]
[0.157] 3.8 [0.150] 2 x Ø5.1 [1.496]
OP Stainless Steel [Ø0.201] 16.0 [0.630]
Roller 7.0 [0.276]
2
7.5 [0.295] Rubber Max
Cap 11.4 [0.45]
73.0 8.0 [0.315]
2x 7.5 [0.30]
[2.874]

2
Max. 49.0 Ø10.2 [0.402]
2.0 23.0 Depth: 6 [0.236] 65.0
102.7
[1.929] [0.079] [0.906] [4.043] [2.559]
23.0 [0.906] Max Max
2.0 8.0

2.0 1.4 1.5


[0.079] [0.31]
2
[0.079] 34.0 [1.339] [0.055] [0.059]
2.0 [0.079]
2
1.4 [0.055] 1.5 [0.059]
34.0 [1.339]
40.0 [1.575]

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-19


2.2 Limit Switches
Compact Prewired Switches

Approximate Dimensions in mm [in]


2
E47BCC20 E47BCC22
2 Ø1.2
16.0 Ø17.5 51.2 [2.017]
[0.69] 7.0 [0.280]
[0.630]
2 50.7
5.7
Max R 25.0–89.0
[0.984–3.600]

2 103.7
[2.5]
2 x Ø5.1 [Ø0.201] 16.0
[0.630]
2 x Ø10.2 [0.402]

2
Depth: 6 [0.236]
4.0
[0.157] 8.0

2
25.0 [0.315]
7.5 [0.295] Rubber [0.984]
Cap
8.0 [0.315]

2 49.0
[1.929] 25.0 23.0 23.0 2.0
[0.984] 2.0 [0.906] [0.906] [0.079]

2
[0.079]

2.0 [0.079] 1.3 1.5


2.0 34.0 [1.339] [0.051] [0.059]
2 [0.079]
34.0 [1.339]
1.4
[0.055]
1.5
[0.059] 40.0 [1.575]

2
40.0 [1.575] 18 AWG/4 18 AWG/4
UL, SJT (0) UL, SJT (0)
Ø 8.5 [0.335] Ø 8.5 [0.335]

2
E47BCC21
2
Ø3.0

2
[0.117]

159.0

2 [6.257]

2 16.0
[0.630]

2 25.9 25.0 8.0


[1.020] [0.984] [0.315]
2
2 23.0
[0.906]
2.0
[0.079]

2 2.0 [0.079]
34.0 [1.339]
1.3
[0.051]
1.5
[0.059]

2
40.0 [1.575]
18 AWG/4 18 AWG/4
UL, SJT (0) UL, SJT (0)

2 Ø8.5 [0.335] Ø8.5 [0.335]

2
2
2
2
2
2
2
2
2

V8-T2-20 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
LS-Titan Miniature DIN Switches
2.3
Contents
LS-Titan Miniature DIN Switches
Description Page
2
LS-Titan Miniature DIN Switches 2
Product Identification . . . . . . . . . . . . . . . . . . . . V8-T2-22
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V8-T2-23 2
LS-Titan Plastic Safety Switches . . . . . . . . . V8-T2-23
LS-Titan Plastic Electronic 2
Safety Position Switches . . . . . . . . . . . . . V8-T2-26
LS-Titan Metal Safety Switches . . . . . . . . . V8-T2-30 2
Understanding LS-Titan Electronic
Safety Position Switches . . . . . . . . . . . . . V8-T2-32 2
Operating Point Adjustment . . . . . . . . . . . . V8-T2-32
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-33 2
Technical Data and Specifications . . . . . . . . . . V8-T2-34
Contact Travel Diagrams . . . . . . . . . . . . . . . . . . V8-T2-37 2
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-40
2
2
LS-Titan Miniature DIN Switches 2
Product Description Features Standards and Certifications 2
Eaton’s LS-Titan™ limit ● Modular, plug-in ● Can be ordered as ● Safety function by positive
switch line is a complete system (head and separate components opening contacts per 2
offering of safety position body components) (head and body) or as IEC/EN 60947-5-1 up to
switches designed for
worldwide application.
● Positive opening NC completely assembled
switches
Category 4 per EN 954-1
2
contacts for safety ● TÜV-Rheinland Certified
Economical insulated
plastic or rugged metal ●
applications
Wide variety of economical
● Screw and Cage Clamp®
(standard on LSE models
for Functional-Safety
(LSE models)
2
enclosures and modular, and optionally available
plastic and rugged metal CSA certified
2

plug-in operating heads versions available on mechanical models)
and bodies make LS-Titan a
● UL listed
connections provide larger
Operating heads can
2

flexible switching solution. wiring areas for easier
● CE
be rotated 90 degrees ● CCC
A highlight of the LS-Titan to suit specific direction installation
switch line is the world’s of operation ● Approved for worldwide 2
first electronic position ● Unique electronic safety application
switch (LSE models). These position switches (LSE 2
switches feature freely models) provide analog
programmable operating
points that can be set
(0–10 Vdc or 4–20 mA) Note: Cage Clamp is a 2
outputs proportional to the registered trademark of
individually at any time.
Additional LSE models
actuator position and allow
for easy configuration of
Wago Kontakttechnik,
32423 Minden, Germany.
2
provide analog outputs a custom trip point
proportional to the 2
actuator position.
LS-Titan switches are suitable 2
for use in safety applications
designed to protect persons 2
or processes.
2
2
2
2
For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
2
For the most current information
on this product, visit our Web site:
www.eaton.com
For Application Assistance in the U.S. and Canada
call 1-800-426-9184. 2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-21


2.3 Limit Switches
LS-Titan Miniature DIN Switches

Product Identification
2
2 1

2
2
2

2
2
2
2
3

2 4
5
6

2
7

2 8
9
j

2
2
2
2 k

2 Notes
1 Basic device 2 Fixing adapter (see Page V8-T2-33) 5 Rotary lever (see Pages V8-T2-23, 8 Actuating rod (see Pages V8-T2-25,

2
(see Pages V8-T2-23 to V8-T2-31) Allows mounting of M22 pushbuttons V8-T2-27 and V8-T2-30) V8-T2-29 and V8-T2-31)
According to EN 50047 3 Roller lever For actuation from the side, for On conveyor belts for lightweight goods
With screw-on cover (see Pages V8-T2-23 and V8-T2-26) pendulum movements 9 Spring-rod (see Pages V8-T2-25,

2 Contacts: 1NO-1NC, 2NO, 2NC


Cage Clamp, screw terminal
For one-sided operation with higher
operating speed
6 Roller plunger (see Pages V8-T2-23,
V8-T2-26 and V8-T2-30)
V8-T2-29 and V8-T2-31)
For flexible actuation from all sides
As snap-action or standard-action switch 4 Angled roller lever For actuation from the side with low j Actuating rod (see Pages V8-T2-25,
2 As electronic snap-action switch
(individually adjustable)
(see Pages V8-T2-23, V8-T2-26 and
7
actuating force V8-T2-29 and V8-T2-31)
V8-T2-30) Adjustable roller lever Withdrawable mechanism from front

2
As 4–20 mA analog signal encoder For actuation along the unit axis (see Pages V8-T2-24, V8-T2-27, k Pushbuttons from the M22 family; see
As 0–10 Vdc analog signal encoder V8-T2-28 and V8-T2-30) M22 catalog (CA04716001E) or
For length adjustment as required www.eaton.com/m22
2 Operating heads can be rotated

2
by 90 degrees.

2
2
2
2
2
2
2
2

V8-T2-22 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
LS-Titan Miniature DIN Switches
2.3
Product Selection
2
LS-Titan Plastic Safety Switches
2
Plastic Safety Plastic Safety Switches
Switch Body Switch Body Catalog Number LS-S02 LS-S20A LS-S11S 2
Output Function 2NC with positive 2NO with slow 1NO and 1NC with
opening contacts make/break positive opening contact 2
Terminal Connection Screw terminal 1 Screw terminal 1 Screw terminal 1
Contact Sequence 11 21 13 23 13 21 2
12 22 14 24 14 22 2
2
Contact Travel Snap-action contact
Assembled Switch = contact closed 0 3.0 6.1 0 2.1 6.1 0 3.0 6.1
11–12 NC 13–14 NO 21–22

2
= contact open 13–14
21–22 NC 23–24 NO
3.0 2.1 21–22
Zw = 4.5 mm ZW = 4.5 mm 13–14
1.6
Zw = 5.5 mm 2
Operating Head Type 2
Head Only Assembled Switch
2
Top Push Roller
Catalog Number
LS-XP
Catalog Number
LS-S02-P LS-S20A-P LS-S11S-P
2
Plunger
2
2
Long Roller Lever LS-XL LS-S02-L LS-S20A-L LS-S11S-L 2
2
2
Short Roller Lever LS-XLS LS-S02-LS LS-S20A-LS LS-S11S-LS
2
2
Large Roller Lever LS-XLB LS-S02-LB LS-S20A-LB LS-S11S-LB
2
2
2
2
Angled Roller
2
LS-XLA LS-S02-LA LS-S20A-LA LS-S11S-LA

2
2
2
Rotary Lever LS-XRL LS-S02-RL LS-S20A-RL LS-S11S-RL

2
2
Notes
1 Cage Clamp versions available. Contact Application Engineering.
2
2
2 For operating head dimensions, see Page V8-T2-40.

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-23


2.3 Limit Switches
LS-Titan Miniature DIN Switches

Plastic Safety Switches, continued


2 Plastic Safety
Switch Body Switch Body Catalog Number LS-S02 LS-S20A LS-S11S

2 Output Function 2NC with positive


opening contacts
2NO with slow
make/break
1NO and 1NC with
positive opening contact

2
Terminal Connection Screw terminal 1 Screw terminal 1 Screw terminal 1
Contact Sequence 11 21 13 23 13 21

2 12 22 14 24 14 22

2 Assembled Switch
Contact Travel
= contact closed 0 3.0 6.1 0 2.1 6.1
Snap-action contact
0 3.0 6.1
11–12 NC 13–14 NO 21–22
2 = contact open
21–22 NC 23–24 NO 13–14
21–22
3.0 2.1
13–14
2
Zw = 4.5 mm ZW = 4.5 mm
1.6
Zw = 5.5 mm

2 Operating Head Type 2


Head Only Assembled Switch
2 Catalog Number Catalog Number
Adjustable LS-XRLA LS-S02-RLA LS-S20A-RLA LS-S11S-RLA
2 Roller Lever
(with 18 mm Roller)

2
2
2
2 Adjustable
Roller Lever
LS-XRLA30 LS-S02-RLA30 LS-S20A-RLA30 LS-S11S-RLA30

(with 30 mm Roller)

2
2
2
2
Adjustable LS-XRLA40 LS-S02-RLA40 LS-S20A-RLA40 LS-S11S-RLA40
2 Roller Lever
(with 40 mm Roller)

2
2
2
2 Adjustable Roller
Lever (with 40 mm
LS-XRLA40R LS-S02-RLA40R LS-S20A-RLA40R LS-S11S-RLA40R
Rubber Roller)
2
2
2
2
Notes
2 1 Cage Clamp versions available. Contact Application Engineering.
2 For operating head dimensions, see Page V8-T2-40.

2
2

V8-T2-24 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
LS-Titan Miniature DIN Switches
2.3
Plastic Safety Switches, continued
Plastic Safety
Switch Body Switch Body Catalog Number LS-S02 LS-S20A LS-S11S
2
Output Function 2NC with positive
opening contacts
2NO with slow
make/break
1NO and 1NC with
positive opening contact 2
1 1 1

2
Terminal Connection Screw terminal Screw terminal Screw terminal
Contact Sequence 11 21 13 23 13 21

12 22 14 24 14 22 2
Assembled Switch
Contact Travel
= contact closed 0 3.0 6.1 0 2.1 6.1
Snap-action contact
0 3.0 6.1
2
11–12 NC 13–14 NO 21–22
= contact open
21–22
3.0
NC 23–24
2.1
NO 13–14
21–22
2
13–14
2
Zw = 4.5 mm ZW = 4.5 mm
1.6
Zw = 5.5 mm

Operating Head Type 2 2


Head Only Assembled Switch
Catalog Number Catalog Number
2
Plastic Rod Lever LS-XRR LS-S02-RR LS-S20A-RR LS-S11S-RR
2
2
2
2
Metal Rod LS-XRRM LS-S02-RRM LS-S20A-RRM LS-S11S-RRM
2
2
2
2
2
Spring Rod (Wobble) 3 LS-XS LS-S02-S LS-S20A-S LS-S11S-S 2
2
2
2
Actuating Rod LS-XOR LS-S02-OR LS-S20A-OR LS-S11S-OR
2
2
2
2
Notes
1 Cage Clamp versions available. Contact Application Engineering. 2
2 For operating head dimensions, see Page V8-T2-40.
3 Not to be used as a safety position switch. Use only in conjunction with snap-action contact.
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-25


2.3 Limit Switches
LS-Titan Miniature DIN Switches

LS-Titan Plastic Electronic Safety Position Switches


2
Plastic Electronic Safety Position Switches
2 Plastic Electronic
Safety Position Switch Body
Switch Body
Catalog Number LSE-11 LSE-02 LSE-AI LSE-AU
2 Output Function 1NO and 1 NC 2NC Analog 4–20 mA Analog 0–10V
Terminal Connections Cage Clamp 1 Cage Clamp 1 Cage Clamp 1 Cage Clamp 1
2 Safety Functions These models may be used in safety-oriented circuits. Visual status Additional diagnostic output that registers a 0V signal in the event
and Approvals LED indication is comparable to positive opening contacts. Certified of a fault. Self-test function continuously tests both outputs for
2 by TÜV as a “Functional-Safety” device. Suitable for protection of
people or processes.
overloads, short circuits to 0V and short circuits to +Ue. Certified by
TÜV to EN 954-1, Category 3 or 4. Suitable for protection of people

2
or processes.

2 Assembled Switch

2
Contact Sequence +Ue +Ue Analog 4–20 mA Analog 0–10V

electron. electron.

2 0V
Q1 Q2
0V
Q1 Q2

2 Contact Travel
= contact closed Q1
0 0.5 5.5 6.1
Q1
0 0.5 5.5 6.1
20
I [mA]
10
U [V]

2 = contact open Q2
default=3.0
Q2
default=3.0 4 S [%]
S [%]
0 100
2
0 100

Operating Head Type 2

2 Head Only
Catalog Number
Assembled Switch
Catalog Number

2 Top Push Roller


Plunger
LS-XP LSE-11-P LSE-02-P LSE-AI-P LSE-AU-P

2
2
2
Long Roller Lever LS-XL LSE-11-L LSE-02-L LSE-AI-L LSE-AU-L

2
2 Short Roller Lever LS-XLS LSE-11-LS LSE-02-LS LSE-AI-LS LSE-AU-LS

2
2
2 Large Roller Lever LS-XLB LSE-11-LB LSE-02-LB LSE-AI-LB LSE-AU-LB

2
2
2
Angled Roller LS-XLA LSE-11-LA LSE-02-LA LSE-AI-LA LSE-AU-LA
2
2
2 Notes
1 A compatible Cage Clamp tool is available as an accessory on Page V8-T2-33.

2 2 For operating head dimensions, see Page V8-T2-40.

V8-T2-26 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
LS-Titan Miniature DIN Switches
2.3
Plastic Electronic Safety Position Switches, continued
Plastic Electronic
Safety Position Switch Body
2
Switch Body
Catalog Number LSE-11 LSE-02 LSE-AI LSE-AU
Output Function 1NO and 1NC 2NC Analog 4–20 mA Analog 0–10V 2
1 1 1 1

2
Terminal Connections Cage Clamp Cage Clamp Cage Clamp Cage Clamp
Safety Functions These models may be used in safety-oriented circuits. Visual status Additional diagnostic output that registers a 0V signal in the event
and Approvals LED indication is comparable to positive opening contacts. Certified of a fault. Self-test function continuously tests both outputs for
by TÜV as a “Functional-Safety” device. Suitable for protection of
people or processes.
overloads, short circuits to 0V and short circuits to +Ue. Certified by
TÜV to EN 954-1, Category 3 or 4. Suitable for protection of people
2
or processes.
2
Assembled Switch 2
2
Contact Sequence +Ue +Ue Analog 4–20 mA Analog 0–10V

electron. electron.

0V
Q1 Q2
0V
Q1 Q2 2
Contact Travel
= contact closed Q1
0 0.5 5.5 6.1
Q1
0 0.5 5.5 6.1
20
I [mA]
10
U [V]
2
= contact open Q2
default=3.0
Q2
default=3.0 4 S [%]
S [%]
2
0 100
0 100
2
Operating Head Type 2
Head Only
Catalog Number
Assembled Switch
Catalog Number
2
Rotary Lever LS-XRL LSE-11-RL LSE-02-RL LSE-AI-RL LSE-AU-RL
2
2
2

Adjustable
2
LS-XRLA LSE-11-RLA LSE-02-RLA LSE-AI-RLA LSE-AU-RLA

2
Roller Lever
(with 18 mm Roller)

2
2
2
2
Adjustable LS-XRLA30 LSE-11-RLA30 LSE-02-RLA30 LSE-AI-RLA30 LSE-AU-RLA30 2
Roller Lever
(With 30 mm Roller)
2
2
2
2
2
Notes 2
1 A compatible Cage Clamp tool is available as an accessory on Page V8-T2-33.
2 For operating head dimensions, see Page V8-T2-40.
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-27


2.3 Limit Switches
LS-Titan Miniature DIN Switches

Plastic Electronic Safety Position Switches, continued


2 Plastic Electronic
Safety Position Switch Body
Switch Body
Catalog Number LSE-11 LSE-02 LSE-AI LSE-AU
2 Output Function 1NO and 1NC 2NC Analog 4–20 mA Analog 0–10V

2
Terminal Connections Cage Clamp 1 Cage Clamp 1 Cage Clamp 1 Cage Clamp 1
Safety Functions These models may be used in safety-oriented circuits. Visual status Additional diagnostic output that registers a 0V signal in the event
and Approvals LED indication is comparable to positive opening contacts. Certified of a fault. Self-test function continuously tests both outputs for
2 by TÜV as a “Functional-Safety” device. Suitable for protection of overloads, short circuits to 0V and short circuits to +Ue. Certified by
people or processes. TÜV to EN 954-1, Category 3 or 4. Suitable for protection of people

2 or processes.

2 Assembled Switch

2 Contact Sequence +Ue +Ue Analog 4–20 mA Analog 0–10V

electron. electron.

2 0V
Q1 Q2
0V
Q1 Q2

2 Contact Travel
= contact closed Q1
0 0.5 5.5 6.1
Q1
0 0.5 5.5 6.1
20
I [mA]
10
U [V]

2 = contact open Q2
default=3.0
Q2
default=3.0 4 S [%]
S [%]
0 100
2 0 100

Operating Head Type 2


2 Head Only
Catalog Number
Assembled Switch
Catalog Number

2 Adjustable
Roller Lever
LS-XRLA40 LSE-11-RLA40 LSE-02-RLA40 LSE-AI-RLA40 LSE-AU-RLA40
(With 40 mm Roller)
2
2
2
2
2 Adjustable
Roller Lever
LS-XRLA40R LSE-11-RLA40R LSE-02-RLA40R LSE-AI-RLA40R LSE-AU-RLA40R
(With 40 mm Roller)
2
2
2
2
Plastic Rod Lever
2
LS-XRR LSE-11-RR LSE-02-RR LSE-AI-RR LSE-AU-RR

2
2
2
2
2
2 Notes
1 A compatible Cage Clamp tool is available as an accessory on Page V8-T2-33.

2 2 For operating head dimensions, see Page V8-T2-40.

V8-T2-28 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
LS-Titan Miniature DIN Switches
2.3
Plastic Electronic Safety Position Switches, continued
Plastic Electronic
Safety Position Switch Body
2
Switch Body
Catalog Number LSE-11 LSE-02 LSE-AI LSE-AU
Output Function 1NO and 1NC 2NC Analog 4–20 mA Analog 0–10V 2
1 1 1 1

2
Terminal Connections Cage Clamp Cage Clamp Cage Clamp Cage Clamp
Safety Functions These models may be used in safety-oriented circuits. Visual status Additional diagnostic output that registers a 0V signal in the event
and Approvals LED indication is comparable to positive opening contacts. Certified of a fault. Self-test function continuously tests both outputs for
by TÜV as a “Functional-Safety” device. Suitable for protection of
people or processes.
overloads, short circuits to 0V and short circuits to +Ue. Certified
by TÜV to EN 954-1, Category 3 or 4. Suitable for protection of people
2
or processes.
2
Assembled Switch
2
Contact Sequence +Ue +Ue Analog 4–20 mA Analog 0–10V

electron. electron.
2
2
Q1 Q2 Q1 Q2
0V 0V

Contact Travel 0 0.5 5.5 6.1 0 0.5 5.5 6.1 I [mA] U [V]
= contact closed Q1 Q1 20 10
2
Q2 Q2
= contact open
2
default=3.0 default=3.0 4 S [%]
S [%]
0 100
0 100

Operating Head Type 2 2


Head Only Assembled Switch
Catalog Number Catalog Number
2
Metal Rod LS-XRRM LSE-11-RRM LSE-02-RRM LSE-AI-RRM LSE-AU-RRM
2
2
2
2
2
Spring Rod (Wobble) 3 LS-XS LSE-11-S LSE-02-S LSE-AI-S LSE-AU-S 2
2
2
2
2
2
Actuating Rod LS-XOR LSE-11-OR LSE-02-OR LSE-AI-OR LSE-AU-OR
2
2
2
2
2
Notes
1 A compatible Cage Clamp tool is available as an accessory on Page V8-T2-33. 2
2 For operating head dimensions, see Page V8-T2-40.
3 Not to be used as a safety position switch. Use only in conjunction with snap-action contact.
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-29


2.3 Limit Switches
LS-Titan Miniature DIN Switches

LS-Titan Metal Safety Switches


2
Metal Safety Switches
2 Metal Safety
Switch Body Switch Body Catalog Number LSM-02 LSM-20A LSM-11S

2
Output Function 2NC with positive 2NO with slow 1NO and 1NC with
opening contacts make/break positive opening contact
Terminal Connection Cage Clamp Cage Clamp Cage Clamp
2 Contact Sequence 11 21 13 23 13 21

2 12 22 14 24 14 22

2 Contact Travel
= contact closed 0 3.0 6.1 0 2.1 6.1
Snap-action contact
0 3.0 6.1
11–12 NC 13–14 NO 21–22
2 Assembled Switch = contact open
21–22
3.0
NC 23–24
2.1
NO 13–14
21–22
Zw = 4.5 mm 13–14
2
ZW = 4.5 mm
1.6
Zw = 5.5 mm

2 Operating Head Type 1


Head Only Assembled Switch
2 Catalog Number Catalog Number
Top Push Roller LSM-XP LSM-02-P LSM-20A-P LSM-11S-P
2 Plunger

2
2
Long Roller Lever LSM-XL LSM-02-L LSM-20A-L LSM-11S-L
2
2
2
2 Angled Roller LSM-XLA LSM-02-LA LSM-20A-LA LSM-11S-LA

2
2
2 Rotary Lever LSM-XRL LSM-02-RL LSM-20A-RL LSM-11S-RL

2
2
2 Adjustable Roller Lever LSM-XRLA LSM-02-RLA LSM-20A-RLA LSM-11S-RLA

2
2
2
2
2
Note
2 1 For operating head dimensions, see Page V8-T2-40.

V8-T2-30 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
LS-Titan Miniature DIN Switches
2.3
Metal Safety Switches, continued
Metal Safety
Switch Body Switch Body Catalog Number LSM-02 LSM-20A LSM-11S
2
Output Function 2NC with positive
opening contacts
2NO with slow
make/break
1NO and 1NC with
positive opening contact 2
2
Terminal Connection Cage Clamp Cage Clamp Cage Clamp
Contact Sequence 11 21 13 23 13 21

12 22 14 24 14 22 2
Contact Travel
= contact closed 0 3.0 6.1 0 2.1 6.1
Snap-action contact
0 3.0 6.1
2
11–12 NC 13–14 NO 21–22
Assembled Switch = contact open
21–22
3.0
NC 23–24
2.1
NO 13–14
21–22
2
13–14
2
Zw = 4.5 mm ZW = 4.5 mm
1.6
Zw = 5.5 mm

Operating Head Type 1 2


Head Only Assembled Switch
Catalog Number Catalog Number
2
Plastic Rod Lever LSM-XRR LSM-02-RR LSM-20A-RR LSM-11S-RR
2
2
2
2
2
2
Metal Rod Lever LSM-XRRM LSM-02-RRM LSM-20A-RRM LSM-11S-RRM
2
2
2
2
2
Spring Rod (Wobble) LSM-XS LSM-02-S LSM-20A-S LSM-11S-S
2
2
2
2
2
2
Note
1 For operating head dimensions, see Page V8-T2-40. 2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-31


2.3 Limit Switches
LS-Titan Miniature DIN Switches

Understanding LS-Titan Electronic Safety Position Switches


2 All four LS-Titan LSE switch The LSE-AI (4–20 mA) and This ensures that a safe Like the electromechanical
2 bodies are safety-rated
products. The LSE-11 and
LSE-AU (0–10V) analog
position switches take
operating state can be
monitored and evaluated at
position switches, LS-Titan
electronic position switches
LSE-02 switch bodies both position data and convert to any time. A self-test function meet Category 3 or 4 of
2 have a freely programmable an analog current or voltage is also present on these the EN 954-1 standard for
operating point and can be value that can then be models. Outputs Q1 and Q2 machine safety when
2 individually adjusted to suit continuously fed into an are continuously tested for configured as a redundant
the application, and can be automation system. These overloads, short circuits to 0V system. All devices are
2 changed as often as required.
These devices feature an
two switches also feature
a diagnostic output for
and short circuits to +Ue. thus suitable for safety
applications that are used
2 LED on the body, providing
simple indication during
additional data processing. for the protection of persons
or processes.
programming and operation.
2
2 Operating Point Adjustment

2 LSE-11 LSE-02

2 fix
adjust

2
2
2 LED 1s
Set
2 Set
fmax ≤ 2 N

2
2
Example of LS-Titan LSE Models in a Safety-Oriented Circuit
2 +24V

2 LSE-11 LSE-11 LSE-11


LS-_
+Ue +Ue +Ue
2 S1 S2 S3 S4

2 Q1 Q1 Q1

2
Q2 Q2 Q2
0V 0V 0V

2 R1 R2 K1

2
2 0V

2 Notes
LSE-11 and LSE-02—individual operating point adjustment.

2 LSE-11 and LSE-02 can be used in safety circuits.


S1 is connected to 24 Vdc
S2, S3 each switch with a delay of 0.7s
2 R1, R2, for example, series element M22-XLED60 (2820 ohms/0.5W)

2
2
2

V8-T2-32 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
LS-Titan Miniature DIN Switches
2.3
Accessories
2
LS-Titan Safety Switches
For Use With Description Notes Catalog Number
2
V1-2-M20 Any M20 screw terminal in 1/2 in. For use with
American pipe thread, metal.
The screw connection must be earthed.
Not total insulation.
V1-2-M20-NA 2
M20
Any M20 screw terminal in 1/2 in. For use with
American pipe thread, molded material.
— V1-2-M20
2
1/2 in
2
EMS20 Any M20 diaphragm bolt. With internal push-through — EMS20
membrane. Will fit cable with an external diameter
of up to 13 mm. Rated IP65 with cable inserted.
2
2
LS-XTW Any Cage Clamp tool. — LS-XTW 2
2
M12A LS-Titan plastic bodies (LS-_) Plug connector, 12 mm, 4-pin male connector M12A
2
1 1 1 4
M12x1 (M12x1). Rated IP65. Molded material.
Color coded to IEC/EN 60947-5-2. 2 2 2
1 3
2
3 3 3

4 4 4 2
2
..-11-.. ..-20-.. ..-02-..
2
M12A5
2
LS-Titan metal bodies (LSM-_) Plug connector, 12 mm, 5-pin male connector 1 1 1 4 M12A5
(M12x1). Rated IP65. Molded material.
Color coded to IEC/EN 60947-5-2. 2 2 2
3
2
1
3 3 3

4 4 4 2
..-11-.. ..-20-.. ..-02-.. 2
M22-LS Any Allows mounting of M22 pushbuttons.
(See the M22 catalog, CA04716001E, for
— M22-LS 2
2
a full selection of pushbuttons.)

2
2
2
2
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-33


2.3 Limit Switches
LS-Titan Miniature DIN Switches

Technical Data and Specifications


2
LS-Titan Miniature DIN Switches—IP66, IP67 Complete Units
2 Units LS, LSM LSE-11/LSE-02 LSE-AI 1 LSE-AU 1

2 General
Standards IEC/EN 60947 IEC/EN 60947 IEC/EN 60947 IEC/EN 60947

2 Climatic proofing Damp heat, constant, to IEC


EN 61000-4
Damp heat, constant, to IEC
EN 61000-4
Damp heat, constant, to IEC
EN 61000-4
Damp heat, constant, to IEC

2
60068-2-78; damp heat, 60068-2-78; damp heat, 60068-2-78; damp heat, 60068-2-78; damp heat,
cyclical, to IEC 60068-2-30 cyclical, to IEC 60068-2-30 cyclical, to IEC 60068-2-30 cyclical, to IEC 60068-2-30
Ambient temperature °F (°C) –13° to 158°F (–25° to 70°C) –13° to 158°F (–25° to 70°C) –13° to 158°F (–25° to 70°C) –13° to 158°F (–25° to 70°C)
2 Mounting position As required As required As required As required

2 Protection type
Terminal capacity of screw
IP66, IP67 IP66, IP67 IP66, IP67 IP66, IP67

2 terminal and Cage Clamp


Solid mm2 1 x (0.5–2.5) 1 x (0.5–2.5) 1 x (0.5–2.5) 1 x (0.5–2.5)

2 Flexible with ferrules to DIN 46228 mm2 1 x (0.5–1.5) 1 x (0.5–1.5) 1 x (0.5–1.5) 1 x (0.5–1.5)
Power Supply
2 Rated voltage Ue Vdc N/A 12–30 24 (–15%/+20%) 24 (–15%/+20%)
Burden current
2 12V Ie mA N/A 15 N/A N/A

2 24V
30V
Ie
I
mA
mA
N/A
N/A
18
19
28–45
N/A
24
N/A

2 Contacts/Switching Capacity
Rated impulse withstand voltage Uimp Vac 4000 N/A N/A N/A
2 Rated insulation voltage Ui V 400 N/A N/A N/A

2
Overvoltage category/ III/3 III/3 N/A N/A
pollution degree
Rated Operational Current
2 AC–15

2 24V
230V/240V
Ie
Ie
A
A
6
6
N/A
N/A
N/A
N/A
N/A
N/A

2 400V/415V Ie A 4 N/A N/A N/A


DC-13
2 24V Ie A 3 0.2 N/A N/A

2
110V Ie A 0.8 N/A N/A N/A
220V Ie A 0.3 N/A N/A N/A

2 Note
1 The following applies for LSE-11 and LSE-02: ensure that the power supply operates correctly when setting the operating point.

2
2
2
2
2
2
2
2
2

V8-T2-34 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
LS-Titan Miniature DIN Switches
2.3
LS-Titan Miniature DIN Switches—IP66, IP67 Complete Units. continued
Units LS, LSM LSE-11/LSE-02 LSE-AI 1 LSE-AU 1
2
Burden Current
2
Analog output Q1
Output voltage (max. 10 mA) Vdc N/A N/A 0–10 2
Output current mA N/A N/A 4–20
Fault scenario V N/A N/A 0 0 2
Resolution
Step tolerance
Steps
Steps
N/A
N/A
N/A
N/A
100
1
100
1
2
Shunt resistor, resistive load ohms N/A N/A <400 >1000 2
Digital diagnostics output Q2
(switching to + pole PNP)
2
Response threshold V N/A N/A Approx. Ue Approx. Ue
mA N/A N/A <200 <200 2
Control circuit reliability
At 24 Vdc/5 mA HF Fault probability <10–7, N/A N/A N/A 2
<1 fault in 107 operations
At 5 Vdc/1 mA HF Fault probability <10–6, N/A N/A N/A 2
<1 failure at 5 x 106 operations
Supply frequency Hz Max. 400 N/A N/A N/A 2
Short-circuit rating to
IEC/EN 60947-5-1 2
Maximum fuse A gG/gL 6 N/A N/A N/A
Repetition accuracy mm ±0.02 ±0.02 ±0.02 ±0.02 2
Note
1 The following applies for LSE-11 and LSE-02: ensure that the power supply operates correctly when setting the operating point.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-35


2.3 Limit Switches
LS-Titan Miniature DIN Switches

LS-Titan Miniature DIN Switches—IP66, IP67 Complete Units


2 Units LS, LSM LSE-11/LSE-02 LSE-AI/LSE-AU LSE-AI/LSE-AU

2 Mechanical Variables
Lifespan
2 Standard-action contact Operations X 106 8 N/A N/A N/A
Snap-action contact Operations X 106 8 3 (electronic) N/A N/A
2 Contact temperature of roller head °C ≤100 ≤100 ≤100 ≤100

2 Mechanical shock resistance


(half-sinusoidal shock, 20 ms)

2
Standard-action contact g 25 N/A N/A N/A
Snap-action contact 9 N/A N/A N/A N/A

2 Basic unit g N/A 30 30 30


Operating frequency Operations/h ≤6000 ≤3000 ≤3000 ≤3000
2 Switching point N/A 0.5–5.5 mm freely adjustable N/A N/A
Hysteresis mm N/A 0.4 0.4 0.4
2 Contact sequence (contact closed mm N/A 0.04 0.06 0.06
open Zw = positive opening clearance)
2 Actuation

2
Mechanical
Actuating force at beginning/

2
end of stroke
Basic units N 1.0/8.0 3.5/8.0 3.5/8.0 3.5/8.0

2 LS(M)-XP N 1.0/8.0 1.0/8.0 1.0/8.0 1.0/8.0


LS(M)-XL N 1.0/8.0 1.0/8.0 1.0/8.0 1.0/8.0
2 LS(M)-XLA N 1.0/8.0 1.0/8.0 1.0/8.0 1.0/8.0
Actuating torque of rotary drives Nm 0.2 0.2 0.2 0.2
2 Maximum operating speed
with DIN cam
2 Basic units for angle of actuation = 0°/30° m/s 1/0.5 1/0.5 1/0.5 1/0.5

2
LS(M)-XRL for angle of actuation = 0° m/s 1.5 1.5 1.5 1.5
LS(M)-XRLA for angle of actuation = 30°, L = 125 mm m/s 1.5 1.5 1.5 1.5

2 LS(M)-XRR for angle of actuation L = 130 mm m/s 1.5 1.5 1.5 1.5
LS(M)-XL for angle of actuation = 30°/45° m/s 1 1 1 1
2 LS(M)-XLA for angle of actuation = 30°/45° m/s 1 1 1 1
LS(M)-XP for angle of actuation = 0°/30° m/s 1/1 1/1 1/1 1/1
2 Electromagnetic Compatibility (EMC)

2
Electrostatic discharge (IEC/EN 61000-4-2, Level 3 ESD)
Air discharge kV 8 8 8

2 Contact discharge kV 4 4 4
Electromagnetic fields V/m 10 10 10
2 (IEC/EN 61000-403, RFI)
Burst pulses (IEC/EN 61000-4-4, Level 3)
2 Supply cables kV 2 2 2
Signal lines kV 2 2 2
2 High-energy pulses (surge) kV 0.5 0.5 0.5
(IEC/EN 61000-4-5)
2 Immunity to line-conducted V 10 10 10
interference to (IEC/EN 610000-4-6)
2
2
2
2

V8-T2-36 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
LS-Titan Miniature DIN Switches
2.3
Contact Travel Diagrams
2
LSE
Contact Travel LSE-11 LSE-02 2
= contact closed Q1 Q2
Q1 Q2 2
Description = contact open

Basic Units 2
2
0 0.5 5.5 6.1 0 0.5 5.5 6.1
Q1
Q1
Q2
default=3.0
Q2
default=3.0
2
Operating Heads 2
2
Roller plunger
LS-XP 0 0.5 5.5 6.1 0 0.5 5.5 6.1
LSM-XP Q1

Q2
Q1
2
Q2
default=3.0
default=3.0 2
Roller lever
LS-XL 0 0.5 9.0 9.6 0 0.5 9.0 9.6
2
2
LSM-XL
Q1 Q1
LS-XL
LS-XLB Q2 Q2
default=4.4 default=4.4 2
Angled roller lever
2
LS-XLA 0 0.5 10 10.8 0 0.5 10 10.8
LSM-XLA
Q1 Q1 2
Q2 Q2
default=5.0 default=5.0 2
Rotary lever
2
LS-XRL 0° 5° 60° 65° 0° 5° 60° 65°
LSM-XRL
Q1 Q1 2
Q2 Q2
default=30° default=30° 2
Adjustable roller lever 2
LS-XRLA 0° 5° 60° 65° 0° 5° 60° 65°
LSM-XRLA
LS-XRLA30
Q1 Q1 2
LS-XRLA40
2
Q2 Q2
LS-XRLA40R
default=30° default=30°

Actuating rod 2
LS-XRR 0° 5° 60° 65° 0° 5° 60° 65°
LSM-XRR
LS-XRRM
Q1 Q1 2
2
LSM-XRRM Q2 Q2
default=30° default=30°

Spring rod 2
2
LS-XS 0° 3° 23° 26° 0° 3° 23° 26°
LSM-XS
Q1 Q1

Q2
default=13°
Q2
default=13°
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-37


2.3 Limit Switches
LS-Titan Miniature DIN Switches

LS and LSM
2 Contact Travel LS-02, LS-S02, LSM-02 LS-11S, LS-S11S, LSM-11S LS-20A, LS-S20A, LSM-20A

2 = contact closed
NC NC NO NC NO NO
Description = contact open 12 11 22 21 14 13 22 21 14 13 24 23
2 Basic Units

2 11–12
0 3.0 6.1
NC 21–22
0 3.0 6.1
13–14
0 2.1 6.1
NO

2 21–22 NC 13–14 23–24 NO


21–22 2.1
Zw = 4.5 mm 3.0 ZW = 4.5 mm

2
13–14
1.6 Zw = 4.5 mm

2 Operating Heads
Roller plunger
2 LS-XP, LSM-XP 0 3.0 6.1 0 3.0 6.1 0 2.1 6.1
11–12 NC 21–22 13–14 NO
2 21–22 NC 13–14 23–24 NO
21–22
2 3.0 2.1 ZW = 4.5 mm
Zw = 4.5 mm
13–14
1.6
2
Zw = 4.5 mm

Roller lever

2 LS-XL, LSM-XL 0 4.4 9.6


21–22
0 4.4 9.6 0 3.3 9.6
11–12 NC 13–14 NO

2 21–22 NC 13–14
21–22
23–24 NO

Zw = 6.9 mm 4.4 3.3


2 13–14
2.3 Zw = 8.7 mm

2 Roller lever, short


LS-XLS
2
0 3.3 6.9 0 3.3 6.9 0 2.2 6.9
11–12 NC 21–22 13–14 NO

2 21–22
3.3
NC 13–14
21–22
23–24
2.2
NO

Zw = 5.0 mm

2 13–14
1.7 Zw = 6.2 mm

2 Roller lever, large

2
LS-XLB 0 6.3 13.4 0 6.3 13.4 0 4.3 13.4
11–12 NC 21–22 13–14 NO

2 21–22
6.3
NC 13–14
21–22
23–24
4.3
NO

Zw = 9.6 mm

2 13–14
3.2 Zw = 12.0 mm

2
2
2
2
2
2
2
2

V8-T2-38 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
LS-Titan Miniature DIN Switches
2.3
LS and LSM, continued
Contact Travel LS-02, LS-S02, LSM-02 LS-11S, LS-S11S, LSM-11S LS-20A, LS-S20A, LSM-20A
2
= contact closed
NC NC NO NC NO NO 2
Description = contact open 12 11 22 21 14 13 22 21 14 13 24 23

Operating Heads 2
2
Angled roller lever
LS-XLA, LSM-XLA 0 5.0 10.8 0 5.0 10.8 0 3.6 10.6
11–12 NC 21–22
13–14
13–14 NO
2
21–22 NC 23–24 NO

Zw = 7.6 mm 5.0 21–22


13–14
3.6 2
2.4 Zw = 9.7 mm
2
Rotary lever
LS-XRL, LSM-XRL 0 65°
2
0 30° 65° 30° 0 22° 65°
Adjustable roller lever 11–12 NC 21–22
13–14
13–14 NO 2
LS-XRLA, LSM-XRLA 21–22 NC 23–24 NO
LS-XRLA30, LS-XRLA40
LS-XRLA40R Zw = 47° 30°
21–22
13–14
22° 2
Actuating rod 15° Zw = 60°
2
LS-XRR, LSM-XRR
LS-XRRM, LSM-XRRM
Spring rod
2
LS-XS, LSM-XS 0 13° 26° 0 13° 26° 0 9° 26° 2
11–12 NC 21–22 13–14 NO

21–22 NC 13–14 23–24 NO 2


13° 21–22 9°
13–14 2

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-39


2.3 Limit Switches
LS-Titan Miniature DIN Switches

Dimensions
2 Approximate Dimensions in Inches (mm)

2 Position Switches

2 LS-_, LSM-_, LSE-_


0.50
2 (12.7)
0.87
(22.0)
2 0.32
(8.2)
0.46
(11.7)
0.98
(25.0)
0.79
(20.0)

2
0.08 0.29 0.17
0.83 (1.95) (7.3)
(21.0) (4.3)

2 0.21
3
2.99 1.97
2.17 (5.3) 1
(76.0) (50.0)
2 (55.0) 2
0.17
(4.3)
2 M20
0.55
(14.0) ø 0.16
Thread 1.32 (4.0)
2 1.22
(31.0)
(33.5)

2
LS-_, LSM-_, LSE-_ LS(M)-_/S
2
0.50
ø0.23
2
≥0.79 (20.0) (12.7)
(5.8)
0.50
30° 0.32 30° (12.7)
2 0.83
(8.2)
0.46 (11.7)
(21.0)
2 26° 26°

≥0.59 (15.0)

2 4.96
(126.0)

2
LS(M)-_/P
2
≥0.79 (20.0)
2
0.50
(12.7)
30° 0.35 30° 0.10
2
(9.0) (2.5)
1.04
(26.5) ≥1.00 (25.4)
2
2
2
Notes
2 1 Tightening torque of cover screws: 0.8 Nm ±0.2 Nm.
2 Only with LS (insulated version).

2
3 Fixing screws 2 x M4 ≥30

MA = 1.5 Nm

2
2
2
2
2

V8-T2-40 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
LS-Titan Miniature DIN Switches
2.3
Approximate Dimensions in Inches (mm)
2
Rotary Lever Roller Lever, Short
LS(M)-_/RL LS(M)-_/LS 2
1.82
(46.2) ≥0.79 30° ø0.51
0.50
(12.7) 0.20
2
(20.0) (13.0) (5.0)
2
1.59
(40.5) 0.20
(5.0)
0.94 1.44 1.18
≥0.79 30°
65
°
65
° 30°
(23.9) ≥1.17
(29.7)
(36.5) (30.0) 2
(20.0)
1.06
(27.0) ø0.55
2
1.57 (14.0)
(40.0) 0.83
(21.0) 2
2
2
Roller Lever Adjustable Roller Lever
LS(M)-_/L LS(M)-_/RLA 2
0.13
(3.4) 0.50
≥0.79
(20.0)
2.14
(54.5)
2
(12.7)
2
≥0.79 0.20 1.83
30° (5.0)
(20.0) 0.51 (13.0) 30° 30° (46.4)
5° ø0.71–1.57
2
1.35 6 65
1.22 ° (18.0–40.0)
(31.0) (34.4)
Adjustable
1.27
2 0.75 (19.0)
to 3.00 (76.0) (32.2) 0.39 2
(10.0)

≥1.75 2
(44.5)
Roller Lever, Large
2
LS(M)-_/LB 1
0.50 2
0.80 (12.7)

30°
(20.4)
ø0.87
0.22
(5.6) Angled Roller Lever
2
≥0.79 (22.0)
(20.0)
LS(M)-_/XLA 2
1.31 0.50
≥1.54
2.06
(52.3) 1.63 0.51
(33.2) (12.7) 0.20 2
(41.3) (13.0) (5.0)
(39.0)
2
1.43

2
(36.3)

30°

≥0.79
2
2
(20.0) ≥0.31
(8.0)

2
Notes
1 Tightening torque of cover screws: 0.8 Nm ±0.2 Nm.
2 Setting range of 54.5 to 97.
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-41


2.3 Limit Switches
LS-Titan Miniature DIN Switches

Approximate Dimensions in Inches (mm)


2
Actuating Rod
2 LS(M)-_/RR LS(M)-_/OR

2 ø0.24
(6.0)
2

0.50
2 3 (12.7)
4

2 ø 0.26
≥0.24
(6.1)

2
(6.5)
1
ø 0.16
(4.0)
65° 65
2 °
4.33
(110.0)
2
2
2
1.22
1.69 (31.0)
(43.0)

2 1.81
(46.0)

2
2
2
2 Notes

2
1 LS_/RR ≤150

LS_/RRM ≤210
2 Approach direction, vertical.

2 3 Guide is done by customer, not included.


4 Maximum push-through.

2
2
2
2
2
2
2
2
2
2
2
2
2

V8-T2-42 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E49 Mini Metal Switches
2.4
Contents
E49 Mini Metal Switches
Description Page
2
E49 Mini Metal Switches 2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V8-T2-44
Technical Data and Specifications . . . . . . . . . . V8-T2-46 2
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-47
Drawings
2
Online
2
2
2
2
2
2
E49 Mini Metal Switches 2
Product Description Features Standards and Certifications
DANGER
2
E49 Mini Metal Limit ● Long life—rated for ● UL Recognized
Switches from Eaton’s 10 million operations ● CE THIS SENSOR IS NOT A
SAFETY DEVICE AND IS NOT
2
electrical sector are designed ● Pre-wired units with ● RoHS
small and tough, with
machinery OEMs in mind.
custom cable lengths INTENDED TO BE USED AS A
SAFETY DEVICE. This sensor 2
available for high volume
is designed only to detect
The small size, metal body
and mechanical life make this ●
customers
“Fingerproof” terminals
and read certain data in an 2
product perfect for switching electronic manner and
applications in packaging,
protect against accidental
shock
perform no use apart from 2
material handling, elevators that, specifically no safety-
Double-spring mechanism
2

and lifts, electronic assembly related use. This sensor
equipment, injection molding for contact reliability product does not include
Grounding terminal self-checking redundant
2

machinery, and auto-vending
machines. The E49 Mini included circuitry, and the failure of
Metal is the ideal switch for Captive screws on this sensor product could
2

those who need a cost- enclosure cover make cause either an energized
effective, compact solution, wiring hassle-free or de-energized output
but don’t want to sacrifice ● SPDT double break condition, which could result 2
durability in the process. in death, serious bodily
injury, or property damage.
2
2
2
2
2
2
2
2
For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
2
For the most current information
on this product, visit our Web site:
www.eaton.com
For Application Assistance in the U.S. and Canada
call 1-800-426-9184. 2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-43


2.4 Limit Switches
E49 Mini Metal Switches

Product Selection
2
2
E49 Mini Metal Switches
Assembled Unit

2
(Switch Body and Head)
Travel to Travel to Force to Minimum 1NO-1NC Contacts
Operating Head Type Operate Contacts Reset Contacts Total Travel Operate Contacts Return Force Catalog Number
2 Side Rotary Lever Side Rotary Lever

2 20° 12° 70° 750g 100g E49G31AP3

2
2
2 Adjustable Side
Rotary Lever
Adjustable Side Rotary Lever
20° 12° 70° 750g 100g E49G31UP3
2
2
2
2 Top Pushbutton Top Pushbutton
0.06 in 0.04 in 0.22 in 900g 150g E49G31BP3
2 (1.5 mm) (1 mm) (5.5 mm)

2
2 Top Push Roller Top Push Roller

2 0.06 in
(1.5 mm)
0.04 in
(1 mm)
0.22 in
(5.5 mm)
900g 150g E49G31CP3

2
2
2 Top Push Roller
(90° Roller)
Top Push Roller (90° Roller)
0.06 in 0.04 in 0.22 in 900g 150g E49G31C1P3
2 (1.5 mm) (1 mm) (5.5 mm)

2
2
2 Adjustable Rod Lever Adjustable Rod Lever
20° 12° 70° 750g 100g E49G31DP3
2
2
2
2
2
2
2

V8-T2-44 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E49 Mini Metal Switches
2.4
E49 Mini Metal Switches, continued
Assembled Unit
2
(Switch Body and Head)
Travel to Travel to Force to 1NO-1NC Contacts 2
Operating Head Type Operate Contacts Reset Contacts Total Travel Operate Contacts Catalog Number
Wobble Stick Wobble Stick (Nylon Coil) 2
(Nylon Coil)
2
1.18 in — — 150g E49G31NP3
(30 mm)

2
2
2
Wobble Stick Wobble Stick (Metal Coil)
2
(Metal Coil)
1.18 in
(30 mm)
— — 150g E49G31VP3
2
2
2
2
2
Wobble Stick Wobble Stick (Metal Rod)
(Metal Rod)
1.18 in — — 150g E49G31MP3 2
(30 mm)
2
2
2
2
Wobble Stick
(Whisker)
Wobble Stick (Whisker) 2
1.18 in — — 150g E49G31XM3
(30 mm) 2
2
2
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-45


2.4 Limit Switches
E49 Mini Metal Switches

Technical Data and Specifications


2
E49 Mini Metal Switches
2 Description Specification

2 Operating speed
Operating frequency
0.19 in (5 mm) to 19.7 in/s (50 cm/s)
120 operations/min

2 Contact resistance 25M ohms (initial)


Insulation resistance 100M ohms min (at 500 Vdc)
2 Dielectric strength 1000 Vac, 50/60 Hz for one minute between non-continuous terminals

2
1500 Vac, 50/60 Hz for one minute between current-carrying and
non-current-carrying parts and between each terminal and ground
Vibration 10 to 55 Hz, 1.5 mm double amplitude
2 Shock Approx. 300 m/s2 (approx. 30Gs)

2 Ambient operating temperature


Humidity
23° to 149°F (–5° to 65°C)
95% RH max.

2 Service life Mechanical: 10,000,000 operations min.


Electrical: 500,000 operations min.
2 Weight Approx. 130 to 190g

2
Degree of protection IEC: IP65
Material of construction Shaft: stainless SUS303
Arm: stainless SUS304
2 Head and body: zinc alloy
Terminal cover: PC/ABS plastic

2 Rubber grommet: NBR rubber

2 Maximum Ampere Ratings

2 Non-Inductive Load (A)


Resistive Load Lamp Load 2
Inductive Load (A) 1
Inductive Load Motor Load
Rated
2 Voltage NC NO NC NO NC NO NC NO
125 Vac 5 5 1.5 0.7 3 3 2 1
2 250 Vac 5 5 1 0.5 3 3 1.5 0.8
8 Vdc 5 5 3 3 5 4 3 3
2 14 Vdc 5 5 3 3 4 4 3 3

2 30 Vdc
125 Vdc
5
0.4
5
0.4
3

3

4

4

3

3

2 250 Vdc 0.2 0.2 — — — — — —

2 Terminal Configuration

2 NO (4) NO (3)

2 NC (1) NC (2)

2
Notes
1 Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 msec. max. (DC).
2 Lamp load has an inrush current of ten times the steady-state current, while motor load has

2 an inrush current of six times the steady-state current.

2
2
2
2
2

V8-T2-46 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E49 Mini Metal Switches
2.4
Dimensions
Approximate Dimensions in Inches (mm) 2
E49G31AP3 E49G31CP3 2
1.62 (41) 0.59 (15)
2
0.70 x 0.28
(18 x 7) Dia. 1.43 (28) 0.50 x 0.15 0.39
(13 x 4) (10)
PT 20° Dia.
2
Max. 1.18 (30) 0.8
(20) 1.5
R M3 x 6 (38)
M3 x 6 0.73
2
0.16 (4.1)
M4 (18) Dia.
0.16 (4.1) 0.49 (12)
Dia.
2.2
(56)
2.52
(64)
2
2.2 2.52
M3 x 23
2
(56) (64)
M3 x 23
M5
M5 (P=0.8)
(P=0.8)
0.55 (14)
0.55 (14)
2
0.83 0.30
0.83
(21)
0.30
(7) 0.6 (15)
(21)
1.1
(7)
0.98
0.6 (15)
2
1.1 0.98 (28) (25)
(28) (25)
2
E49G31BP3 E49G31DP3
2
0.12 (3) 1.77 (45)
0.39
(10) 0.22 (6) 1.41
(36)
2
M3 x 6 0.10 (3)
2
1.06 (27) Dia.
0.16 (4.1) 1.18~4.65 0.8
Dia. M4 (30~118) (20)

2.2 2.52
M3 x 6
0.16 (4.1) 0.49 (12)
M6 0.73
(18) 2
(56) (64) Dia.
M3 x 23
2
M5
2.2 2.52
2
(P=0.8)
0.55 (14) (56) (64)
M3 x 23
0.83 0.30
(21)
1.1
(7)
0.98
0.6 (15)
M5
(P=0.8) 2
(28) 0.55 (14)
(25)
0.83 0.30 2
(21) (7) 0.6 (15)
1.1
(28)
0.98
(25) 2
E49G31C1P3 E49G31MP3 2
0.50 x 0.15
(13 x 4)
0.59 (15)
0.39 0.11 (3)
0.40
(10) 2
Dia. (10) Dia.

M3 x 6
1.5
(38)
1.65
(42)
2
0.16 (4.1)
Dia. 3.94 0.23 (6)
Dia.
2
(100)

2.2 2.52 2
(56) (64) M3 x 6
M3 x 23
M5
0.16 (4.1)
Dia.
2
(P=0.8)
0.55 (14)
2.2 2.52
2
0.83 0.30 (56) (64)
(21)
1.1
(7)
0.98
0.6 (15) M3 x 23 2
(28) (25) M5
(P=0.8)
0.55 (14) 2
0.83
(21)
0.30
(7) 0.6 (15) 2
1.1 0.98
(28) (25)
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-47


2.4 Limit Switches
E49 Mini Metal Switches

Approximate Dimensions in Inches (mm)


2
E49G31NP3 E49G31VP3
2 0.40 0.40
0.11 (3) (10) (10)
2 1.65
Dia.

2
(42)
3.94
3.94 0.23 (6) (100)
Dia.
2 (100)

M3 x 6
2 M3 x 6
0.16 (4.1)
0.16 (4.1)
Dia.
Dia.
2 2.2 2.52
2.2 2.52 (56) (64)
2 M3 x 23
(56) (64) M3 x 23
M5
2 M5
(P=0.8)
(P=0.8)
0.55 (14)
0.55 (14)
2 0.83 0.30
0.83 0.30 (21) (7) 0.6 (15)
(21) (7) 0.6 (15) 1.1 0.98
2 1.1
(28)
0.98
(25)
(28) (25)

2 E49G31UP3 E49G31XM3
2 1.89 (48) 0.40
1.69 (43) (10)

2 0.70 x 0.28
L=
1.18~2.75
1.30 (33)
1.10 (28)
2.05 0.04 (1)
(18 x 7) (30~70)
(52)
2 Dia. Dia.
0.8 3.94
(20) (100)
2 M4
M3 x 6 M6 0.73 M3 x 6
2 0.16 (4.1)
Dia.
0.49 (12) (18)
0.16 (4.1)
Dia.

2 2.2 0.08 2.52 2.2 2.52


(56) (2) (64) (56) (64)
2 M3 x 23
M5
M3 x 23
M5
2
(P=0.8) (P=0.8)
0.55 (14) 0.55 (14)
0.83 0.30
2 (21)
1.1
(7)
0.98
0.6 (15)
0.83
(21)
0.30
(7) 0.6 (15)
1.1 0.98
(28) (25)
2 (28) (25)

2
2
2
2
2
2
2
2

V8-T2-48 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E49 Compact Metal Switches
2.5
Contents
E49 Compact Metal Switches
Description Page
2
E49 Compact Metal Switches 2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V8-T2-50
Technical Data and Specifications . . . . . . . . . . V8-T2-52 2
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-53
Drawings
2
Online
2
2
2
2
2
2
E49 Compact Metal Switches 2
Product Description Features Standards and Certifications
DANGER
2
E49 Compact Metal Switches ● Rigid die cast switch ● cULus
by Eaton’s electrical sector housing ● NEMA A600 (AC-15) THIS SENSOR IS NOT A
SAFETY DEVICE AND IS NOT
2
are designed with high ● High mechanical strength ● NEMA R300 (DC-13)
mechanical strength for
robust environments. The
● Oil-tight, waterproof and ● IP67
INTENDED TO BE USED AS A
SAFETY DEVICE. This sensor 2
dustproof construction ● RoHS is designed only to detect
rugged aluminum die cast
construction provides and read certain data in an 2
reliable, oil-tight, waterproof electronic manner and
and dustproof sealing for a perform no use apart from 2
variety of applications. Snap that, specifically no safety-
action 1NO-1NC contacts
provide flexibility in design.
related use. This sensor
product does not include
2
self-checking redundant
circuitry, and the failure of 2
this sensor product could
cause either an energized 2
or de-energized output
condition, which could result 2
in death, serious bodily
injury, or property damage.
2
2
2
2
2
2
2
2
For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
2
For the most current information
on this product, visit our Web site:
www.eaton.com
For Application Assistance in the U.S. and Canada
call 1-800-426-9184. 2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-49


2.5 Limit Switches
E49 Compact Metal Switches

Product Selection
2
2
E49 Compact Metal Switches
Assembled Unit

2
(Switch Body and Head)
Travel to Travel to Force to Operate Minimum 1NO-1NC Contacts
Operating Head Type Operate Contacts Reset Contacts Total Travel Contacts (Maximum) Return Force Catalog Number
2 Roller Lever Roller Lever

2 20° 12° 50° 2.99 lbs 0.50 lb E49M11AP1

2
2
2
Top Push Top Push
2 0.067 in 0.04 in — 6.02 lbs 2.01 lbs E49M11BP1
(1.7 mm) (1.0 mm)
2
2
2
2 Top Push Roller Top Push Roller
0.067 in 0.04 in 0.25 in 6.02 lbs 2.01 lbs E49M11CP1
2 (1.7 mm) (1.0 mm) (6.5 mm) (as pictured)

2
E49M11CP2
2 90° Cross Roller

2
2 Rod Lever Rod Lever
20° 12° 50° 0.31 lb 0.06 lb E49M11DP1

2
2
2
2
2
2
2
2
2
2
2
2

V8-T2-50 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E49 Compact Metal Switches
2.5
E49 Compact Metal Switches, continued
Assembled Unit
2
(Switch Body and Head)
Travel to Travel to Force to Operate Minimum 1NO-1NC Contacts 2
Operating Head Type Operate Contacts Reset Contacts Total Travel Contacts (Maximum) Return Force Catalog Number
Adjustable Roller
Lever
Adjustable Roller Lever 2
2
20° 12° 50° 2.99 lbs 0.50 lb E49M11UP1

2
2
2
2
Wobble Wobble
1.10 in N/A N/A 0.33 lb N/A E49M11VP1

2
(28 mm)

2
2
2
2
Cat Whisker Cat Whisker
1.10 in N/A N/A 0.064 lb N/A E49M11XM1 2
(28 mm)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-51


2.5 Limit Switches
E49 Compact Metal Switches

Technical Data and Specifications


2
E49 Compact Metal Switches
2 Description Specification

2 Operating speed
Operating frequency
1 mm to 2m/sec
Mechanically: 120 operations/min.; Electronically: 30 operations/min.

2 Contact resistance 15M ohms max. (initial)


Insulation resistance 100M ohms min. (at 500 Vdc)
2 Dielectric strength 1000 Vac, 50/60 Hz for 1 minute between non-continuous terminals;
2200 Vac, 50/60 Hz for 1 minute between each terminal and non-current carrying
2 metal part and between each terminal and ground
Vibration Malfunction durability: approx. 1000 m/sec2 (approx. 100 Gs);
2 Ambient operating temperature
Malfunction durability: approx. 300/sec2 (30 Gs)
14° to 176°F (–10° to 80°C)

2 Humidity 95% RH max.


Service life Mechanically: 15,000,000 operations/minute;
2 Electronically: 500,000 operations/minute

2
Maximum Ampere Ratings—Isolated Contacts, No Polarity Restriction
2 NEMA A600 (AC-15) 50 or 60 Hz NEMA R300 (DC-13)
Rated Current Voltamperes Rated
2 Voltage Continuous Make Break Make Break Voltage Current
24 Vac 10A 60A 6.0A 7200 VA 720 VA 24 Vdc 1.5A
2 120 Vac 10A 60A 6.0A 7200 VA 720 VA 120 Vdc 0.22A

2 250 Vac
480 Vac
10A
10A
30A
15A
3.0A
1.5A
7200 VA
7200 VA
720 VA
720 VA
250 Vdc 0.11A

2 600 Vac 10A 12A 1.2A 7200 VA 720 VA

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

V8-T2-52 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E49 Compact Metal Switches
2.5
Dimensions
Approximate Dimensions in Inches (mm) 2
Switch Body with E49M11BP1 E49M11UP1 2
0.35 (9.0) 2.64 (67.0)
Dia. 0.50 (12.7)
0.69 (17.5)
Dia. 2.36 (60.0) 2
0.28 (7.0)
0.78
(19.9) 2
0.98 (25.0)

2.31
4-M6
Thread 2.71
to
3.51 (89.0)
1.00
2
(58.7) (68.7) (25.4)
0.58 (14.7)
2
0.20
0.59 (15.1)
0.19 (4.9)
0.85 (21.6)
1.15 (29.2)
2
(5.0)
1.58
(40.0)
1.19 (30.2)
1.63
(41.5)
1.38 (35.0)
2
2
E49M11CP1/E49M11CP2 E49M11VP1
0.50 (12.7) 0.26 (6.5) 0.52 2
0.67 (17.0) 0.20 (5.0) Dia. (13.1)
Dia.
2
1.10 (28.0)
5.51 2
(140.0)

2
2
2
E49M11DP1 E49M11XM1
0.35 (9.0)
2.17 (55.0)
2
2.03
0.12 (3.0)
Dia.
1.81
(46.0)
(51.5)
2
5.51
0.98 (25.0)
to
(140.0) 2
5.51 (140.0)
1.00 2
(25.4)
0.58 (14.7)
2
2
E49M11AP1 2
2
2.32 (59.0)
0.69 (17.5) 2.09
Dia. (53.0)
0.28
(7.0) 2
1.84
(46.6)
1.00
2
(25.4)
0.58 (14.7)
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-53


2.6 Limit Switches
E50 Heavy-Duty Plug-In Switches

Contents
2 E50 Heavy-Duty Plug-In Switches
Description Page
2 E50 Heavy-Duty Plug-In Switches
Product Selection
2 Assembled Switches—Standard . . . . . . . . . V8-T2-55
Assembled Switches—Special Purpose . . . V8-T2-58
2 Operating Heads . . . . . . . . . . . . . . . . . . . . . V8-T2-59
Switch Bodies . . . . . . . . . . . . . . . . . . . . . . . V8-T2-60
2 Receptacles . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-61

2
Compatible Connector Cables . . . . . . . . . . V8-T2-62
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-62

2 Technical Data and Specifications . . . . . . . . . .


Circuit Diagrams . . . . . . . . . . . . . . . . . . . . . . . .
V8-T2-64
V8-T2-65
2 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . V8-T2-65
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-66
2 Drawings
Online
2
2 E50 Heavy-Duty Plug-In Switches
2 Product Description Features Standards and Certifications
E50 Modular Plug-In Limit ● Modular, plug-in ● E50 devices can be ● UL Listed
2 Switch Components from components (head, body ordered in separate
components or as
● CSA Certified
Eaton’s electrical sector are and receptacle) provide ● IEC.947.5.1
2 the industry standard with
versatility of design and
application flexibility,
reduced inventory and less
complete assembled
switches ● TUV—E9271605E02
● CE (where shown)
2 high reliability for low downtime 600V rating, ridge-topped

maintenance, installation and ● Manufactured to take the contacts and wiping action
inventory costs. Standard physical and assure continuity even to
2 Viton gaskets, seals and environmental abuse logic level circuits
boots and a zinc die cast (including cutting fluids ● Keyed, four direction head
2 enclosure provide exceptional
chemical resistance to the
and chemicals) of harsh positioning
industrial environments ● Standard 5° pre-travel and
2 common coolants, cleansing
agents, and hydraulic fluids
● Chemical resistant Viton 90° total travel DANGER
gaskets, seals and boots ● 24–120 Vac/dc LED and
found in machine tool,
2 automotive, waste water
are standard, and so are
captive, posi-drive screws
120 Vac neon indicating
THIS SENSOR IS NOT A
SAFETY DEVICE AND IS NOT
treatment and other heavy- lights available INTENDED TO BE USED AS A
2 duty industrial applications.
● The switches have
terminal identification on
● Rotary heads are field SAFETY DEVICE. This sensor
Mounting dimensions convertible CW, CCW, or is designed only to detect
2 accommodate both U.S. and the nameplate for a visual both, without special tools and read certain data in an
DIN standards for easy wiring checkout without ● Epoxy filled, pin connector electronic manner and
guesswork. Heads and
2 retrofit installations. Super
bright 24–120 Vac/dc LED switch bodies can be
or pigtail pin connector
receptacles available
perform no use apart from
that, specifically no safety-
indicating light versions replaced without rewiring
related use. This sensor
2 simplify setup and product does not include
troubleshooting operations. self-checking redundant
2 circuitry, and the failure of
this sensor product could
2 cause either an energized
or de-energized output
2 condition, which could result
in death, serious bodily
injury, or property damage.
2
2
2 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
For the most current information
2 on this product, visit our Web site:
www.eaton.com
For Application Assistance in the U.S. and Canada
call 1-800-426-9184.

V8-T2-54 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Plug-In Switches
2.6
Product Selection
2
Assembled Switches—Standard
2
Assembled Switch E50 Heavy-Duty Plug-In Switches, Assembled—Standard
2
2
2
Single-Pole (5 Terminal Receptacle) Two-Pole (9 Terminal Receptacle) 2
LED Neon LED Neon LED Neon
Indicating Light: None (24–120 Vac/dc) (120 Vac) None (24–120 Vac/dc) (120 Vac) (24–120 Vac/dc) (120 Vac) 2
E50SA E50SAL E50SAN E50SB E50SBL E50SBN E50SCL
Switch Body:
Receptacle: 1
1NO-1NC
E50RA
1NO-1NC
E50RA
1NO-1NC
E50RA
2NO-2NC
E50RB
2NO-2NC
E50RB
2NO-2NC
E50RB
1NO-2NC
E50RB

E50RB
2
Operating Head Type 2 Description
Assembled Switch (Head + Receptacle + Body)
Catalog Number
Assembled Switch (Head + Receptacle + Body)
Catalog Number 2
Side Rotary Side Rotary (requires an operating lever, see Page V8-T2-80)
2
Standard spring E50AR1 E50ALR1 E50ANR1 E50BR1 E50BLR1 E50BNR1 — —
return—E50DR1 3
2
Low force spring E50AL1 E50ALL1 E50ANL1 E50BL1 E50BLL1 E50BNL1 — —
return—E50DL1 3 2
Maintained two-
position—E50DM1
E50AM1 E50ALM1 E50ANM1 E50BM1 E50BLM1 E50BNM1 — —
2
Side Pushbutton 2
Spring Return Spring return— E50AS1 E50ALS1 E50ANS1 E50BS1 E50BLS1 E50BNS1 E50CLS1 —
E50DS1 2
2
Adjustable Spring Adjustable spring E50AS2 E50ALS2 E50ANS2 E50BS2 E50BLS2 E50BNS2 E50BLS2 E50CNS2 2
Return return—E50DS2
2
2
Circuit Diagrams, see Page V8-T2-65.
2
Notes
1 Connection options (add the code suffix from the table below to the end of the catalog number): 2
Mating Cordset
Option Catalog Number Code Suffix 2
Mini-connector 4 (with epoxy filled receptacle) Single-pole (5-pin mini-connector) CSMS5D5CY1602 P5 5
Two-pole (9-pin mini-connector) CSMS9D9CY1602 P9 5 2
2
Micro-connector 4 (with epoxy filled receptacle) Single-pole (5-pin micro-connector) CSDS5A5CY2202 A5 5

Cable connection (with epoxy filled receptacle) 8 ft cable length — S


12 ft cable length — S12 2
20 ft cable length — S20
Manifold mount (rear wiring entrance) — M 2
20 mm conduit entrance — 20

2
2
For operating head specifications, see Page V8-T2-59.

2
3 CW (clockwise) and CCW (counterclockwise) operation, easily convertible to CW only or CCW only operation.
4 For a full selection of cable connectors, see Tab 10, section 10.1.
5 Refer to Page V8-T2-65 for wiring diagrams.
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-55


2.6 Limit Switches
E50 Heavy-Duty Plug-In Switches

E50 Heavy-Duty Plug-In Switches, Assembled—Standard, continued


2 Assembled Switch

2
2
2 Single-Pole (5 Terminal Receptacle) Two-Pole (9 Terminal Receptacle)

2 Indicating Light: None


LED
(24–120 Vac/dc)
Neon
(120 Vac) None
LED
(24–120 Vac/dc)
Neon
(120 Vac)
LED
(24–120 Vac/dc)
Neon
(120 Vac)
E50SA E50SAL E50SAN E50SB E50SBL E50SBN E50SCL
2 Switch Body: 1NO-1NC 1NO-1NC 1NO-1NC 2NO-2NC 2NO-2NC 2NO-2NC 1NO-2NC —
Receptacle: 1 E50RA E50RA E50RA E50RB E50RB E50RB E50RB E50RB
2 Operating Head Type 2 Description
Assembled Switch (Head + Receptacle + Body)
Catalog Number
Assembled Switch (Head + Receptacle + Body)
Catalog Number

2 Side Push Roller Side Push Roller


Spring return— E50AS3 E50ALS3 E50ANS3 E50BS3 E50BLS3 E50BNS3 E50BLS3 —
2 E50DS3 3

2
2 Side Pushbutton Side Pushbutton
Maintained— E50AH1 E50ALH1 E50ANH1 E50BH1 E50BLH1 E50BNH1 E50BLH1 —

2 E50DH1

2
Top Pushbutton
2 Spring Return Spring return— E50AT1 E50ALT1 E50ANT1 E50BT1 E50BLT1 E50BNT1 E50CLT1 E50BNT1
E50DT1
2
2
2 Adjustable Spring
Return
Adjustable spring
return—E50DT2
E50AT2 E50ALT2 E50ANT2 E50BT2 E50BLT2 E50BNT2 — —

2
2
2 Circuit Diagrams, see Page V8-T2-65.

2 Notes
1 Connection options (add the code suffix from the table below to the end of the catalog number):

2 Mating Cordset
Option Catalog Number Code Suffix
2 Mini-connector 4 (with epoxy filled receptacle) Single-pole (5-pin mini-connector) CSMS5D5CY1602 P5 5
Two-pole (9-pin mini-connector) CSMS9D9CY1602 P9 5
2 Micro-connector 4 (with epoxy filled receptacle) Single-pole (5-pin micro-connector) CSDS5A5CY2202 A5 5

2 Cable connection (with epoxy filled receptacle) 8 ft cable length


12 ft cable length


S
S12

2 20 ft cable length — S20


Manifold mount (rear wiring entrance) — M
2 20 mm conduit entrance — 20

2 2
3
For operating head specifications, see Page V8-T2-59.
Roller can be converted in the field between horizontal and vertical.
4 For a full selection of cable connectors, see Tab 10, section 10.1.
2 5 Refer to Page V8-T2-65 for wiring diagrams.

V8-T2-56 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Plug-In Switches
2.6
E50 Heavy-Duty Plug-In Switches, Assembled—Standard, continued
Assembled Switch
2
2
2
Single-Pole (5 Terminal Receptacle) Two-Pole (9 Terminal Receptacle) 2
Indicating Light: None
LED
(24–120 Vac/dc)
Neon
(120 Vac) None
LED
(24–120 Vac/dc)
Neon
(120 Vac)
LED
(24–120 Vac/dc)
Neon
(120 Vac) 2
E50SA E50SAL E50SAN E50SB E50SBL E50SBN E50SCL
Switch Body: 1NO-1NC 1NO-1NC 1NO-1NC 2NO-2NC 2NO-2NC 2NO-2NC 1NO-2NC — 2
Receptacle: 1 E50RA E50RA E50RA E50RB E50RB E50RB E50RB E50RB

Operating Head Type 2 Description


Assembled Switch (Head + Receptacle + Body)
Catalog Number
Assembled Switch (Head + Receptacle + Body)
Catalog Number
2
Top Push Roller Top Push Roller 2
Spring return E50AT3 E50ALT3 E50ANT3 E50BT3 E50BLT3 E50BNT3 — —
E50DT3 3 2
2
Wobble Head, Wobble Head, Spring Return
2
Spring Return (requires a wobble operator, see Page V8-T2-80)
Standard duty— E50AW1 E50ALW1 E50ANW1 E50BW1 E50BLW1 E50BNW1 EB50BLW1 — 2
E50DW1
2
Heavy-duty high E50AW2 E50ALW2 E50ANW2 E50BW2 E50BLW2 E50BNW2 E50CLW2 E50BNW2
strength steel—
E50DW2
2
Circuit Diagrams, see Page V8-T2-65. 2
Notes
1 Connection options (add the code suffix from the table below to the end of the catalog number): 2
Option
Mating Cordset
Catalog Number Code Suffix 2
Mini-connector 4 (with epoxy filled receptacle) Single-pole (5-pin mini-connector)
Two-pole (9-pin mini-connector)
CSMS5D5CY1602
CSMS9D9CY1602
P5 5
P9 5
2
Micro-connector 4 (with epoxy filled receptacle) Single-pole (5-pin micro-connector) CSDS5A5CY2202 A5 5 2
Cable connection (with epoxy filled receptacle) 8 ft cable length — S
12 ft cable length — S12 2
20 ft cable length — S20
Manifold mount (rear wiring entrance) — M
2
20 mm Conduit Entrance — 20
2
2 For operating head specifications, see Page V8-T2-59.
3
4
Roller can be converted in the field between horizontal and vertical.
For a full selection of cable connectors, see Tab 10, section 10.1.
2
2
5 Refer to Page V8-T2-65 for wiring diagrams.

2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-57


2.6 Limit Switches
E50 Heavy-Duty Plug-In Switches

Assembled Switches—Special Purpose


2
E50 Heavy-Duty Plug-In Switches, Assembled—Special Purpose
2 Operating Data— Assembled Switch Switch Body Only Receptacle Only Operating Head Only
Nominal Switches Catalog Number Catalog Number Catalog Number Catalog Number
2 Neutral Position Neutral Position (requires an operating lever, see Page V8-T2-80)

2 5° Travel
5° Travel; stainless steel shaft
E50NN1 1
E50NN1SPL 2
E50SN

E50RB

E50DN1 1

2 15° Travel E50NN2 E50SN E50RB E50DN2 1


Travel to operate contacts: 5° or 15° 3 5° or 15° 3 5° or 15° 3 5° or 15° 3
2 Travel to reset contacts:
Total travel:

90°

90°

90°

90°
Force to operate contacts: 1.8 in-lbs 1.8 in-lbs 1.8 in-lbs 1.8 in-lbs
2 Minimum return force:
Operating temperature:
2.5 in-oz
14° to 200°F (–10° to 94°C)
2.5 in-oz
14° to 200°F (–10° to 94°C)
2.5 in-oz
14° to 200°F (–10° to 94°C)
2.5 in-oz
14° to 200°F (–10° to 94°C)

2 Two-Step Two-Step CW, CCW, or both, Convertible (requires an operating lever, see Page V8-T2-80)
— E50TD1 E50ST E50RB E50DD1
2 Travel to operate contacts: 1st step 10°; 1st step 10°; 1st step 10°; 1st step 10°;
2nd step 20° 2nd step 20° 2nd step 20° 2nd step 20°
2 Travel to reset contacts:
Total travel:
4° each
90°
4° each
90°
4° each
90°
4° each
90°
Force to operate contacts: 3 in-lbs 3 in-lbs 3 in-lbs 3 in-lbs
2 Minimum return force:
Operating temperature:
4.5 in-oz
CW or CCW:
4.5 in-oz
CW or CCW:
4.5 in-oz
CW or CCW:
4.5 in-oz
CW or CCW:

2
14° to 250°F (–10° to 121°C) 14° to 250°F (–10° to 121°C) 14° to 250°F (–10° to 121°C) 14° to 250°F (–10° to 121°C)
CW and CCW: CW and CCW: CW and CCW: CW and CCW:
14° to 200°F (–10° to 94°C) 14° to 200°F (–10° to 94°C) 14° to 200°F (–10° to 94°C) 14° to 200°F (–10° to 94°C)
2 Gravity Return Gravity Return (requires E50KL220, E50KL226 or equivalent operating lever, see Page V8-T2-80)
Without indicating light E50GG1 E50SG E50RA E50DG1
2 With LED indicating light E50GLG1 E50SGL E50RA E50DG1
(24–120 Vac/dc)
2 With neon indicating light E50GNG1 E50SGN E50RA E50DG1
(120 Vac)
2 Travel to operate contacts: 10° to 170° 10° to 170° 10° to 170° 10° to 170°
Travel to reset contacts: 8° 8° 8° 8°
2 Total travel:
Force to operate contacts:
360°
3.0 in-oz
360°
3.0 in-oz
360°
3.0 in-oz
360°
3.0 in-oz
Minimum return force: Gravity Gravity Gravity Gravity
2 Operating temperature: 14° to 200°F (–10° to 94°C) 14° to 200°F (–10° to 94°C) 14° to 200°F (–10° to 94°C) 14° to 200°F (–10° to 94°C)
Circuit Diagrams, see Page V8-T2-65.
2 Notes
1 Add 9 suffix to the model number for low temperature –40° to 174°F (–40 to 79°C) versions.

2 2 Low temperature rating –40° to 174°F (–40° to 79°C)


3 Depending upon model selected.

2
2
2
2
2
2
2
2
2
2

V8-T2-58 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Plug-In Switches
2.6
Operating Heads
2
E50 Heavy-Duty Plug-In Switches, Operating Heads
Operating Temperature 1 2
Travel to Travel to Force to Minimum

Description
Operate
Contacts
Reset
Contacts
Total
Travel
Operate
Contacts
Return
Force Without Cable
With
Pre-Wired Cable
Catalog
Number 2
Side Rotary Side Rotary (requires an operating lever, see Page V8-T2-80)
2
Standard spring return 2 5° 2° 90° 3 in-lbs 4.5 in-oz 10° to 200°F 10° to 200°F E50DR1

Low temperature 5° 2° 90° 3 in-lbs 4.5 in-oz


(–12° to 94°C) 3 (–12° to 94°C) 3
–40° to 175°F –31° to 175°F E50DR19
2
2
spring return 2 (–40° to 79°C) (–34° to 79°C)
Low force spring return 2 15° 6° 90° 1.5 in-lbs 2.5 in-oz 10° to 200°F 10° to 200°F E50DL1
(–12° to 94°C) 3 (–12° to 94°C) 3
Maintained two-position 50° 50° 90° 3 in-lbs — 14° to 200°F 14° to 200°F E50DM1
2
(–10° to 94°C) (–10° to 94°C)
Side Pushbutton 2
Spring Return Spring return 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14° to 200°F
(–10° to 94°C)
14° to 200°F
(–10° to 94°C)
E50DS1
2
2
2
Adjustable Spring Adjustable spring return 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14° to 200°F 14° to 200°F E50DS2
Return (–10° to 94°C) (–10° to 94°C)
2
2
2
Side Push Roller Side Push Roller
Spring return 4 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14° to 200°F 14° to 200°F E50DS3 5 2
(–10° to 94°C) (–10° to 94°C)

0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14° to 200°F 14° to 200°F E50DS4 5


2
(–10° to 94°C) (–10° to 94°C)
2
Side Pushbutton Side Pushbutton
Maintained 0.200 in 0.130 in 0.320 in 5 lbs 5 lbs 14° to 200°F
(–10° to 94°C)
14° to 200°F
(–10° to 94°C)
E50DH1 2
2
Top Pushbutton 2
Spring Return
2
Spring return 0.040 in 0.020 in 0.280 in 4 lbs 8 oz 14° to 250°F 14° to 221°F E50DT1
(–10° to 121°C) (–10° to 105°C)

2
2
Adjustable Spring
2
Adjustable spring return 0.040 in 0.020 in 0.280 in 4 lbs 8 oz 14° to 250°F 14° to 221°F E50DT2
Return (–10° to 121°C) (–10° to 105°C)

2
2
Notes
1 Temperature ranges below 32°F (0°C) are based on absence of freezing moisture or water.
2
2 CW (clockwise) and CCW (counterclockwise) operation, easily convertible to CW only or CCW only operation.
3 For CW and CCW operation. For CW only or CCW only operation, high temperature limit increases to 250°F (121°C) without cable,
2
and 221°F (105°C) with pre-wired cable.
4 Roller can be converted in the field between horizontal and vertical. 2
5 Roller shaft is 0.38 in (9.5 mm) longer on E50DS4, see Dimensions on Page V8-T2-66.

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-59


2.6 Limit Switches
E50 Heavy-Duty Plug-In Switches

E50 Heavy-Duty Plug-In Switches, Operating Heads, continued


2 Operating Temperature 1
Travel to Travel to Force to Minimum
2 Description
Operate
Contacts
Reset
Contacts
Total
Travel
Operate
Contacts
Return
Force Without Cable
With
Pre-wired Cable
Catalog
Number

2 Top Push Roller Top Push Roller


Spring return 0.040 in 0.020 in 0.280 in 4 lbs 8 oz 14° to 250°F 14° to 221°F E50DT3
2 (–10° to 121°C) (–10° to 105°C)

2
2 Wobble Head, Wobble Head, Spring Return (requires a wobble operator, see Page V8-T2-80)
Spring Return
2 Standard duty 10° 6° 15° 2 in-lbs 2.4 in-oz 14° to 250°F
(–10° to 121°C)
14° to 221°F
(–10° to 105°C)
E50DW1

2 Heavy-duty high strength steel 10° 6° 15° 2 in-lbs 2.4 in-oz 14° to 250°F 14° to 221°F E50DW2
(–10° to 121°C) (–10° to 105°C)
2
2
2 Switch Bodies

2 E50 Heavy-Duty Plug-In Switches, Switch Bodies

2
2
2
Two-Pole 2NO-2NC Two-Pole 2NC-1NO
2 Single-Pole 1NO-1NC Parallel Wired Indicator Light Series Wired Indicator Light
Switch Body Construction 1 Catalog Number Catalog Number Catalog Number

2 Without indicating light E50SA E50SB —

2 With LED indicating light 24–120 Vac/dc E50SAL E50SBL E50SCL

2 With neon indicating light 120 Vac E50SAN E50SBN —


Circuit Diagrams, see Page V8-T2-65.

2 Note
1 Indicating lights are supplied from the factory wired as shown in Circuit Diagrams on Page V8-T2-65.

2 However, they can be easily re-connected to terminals 1 and 2 if necessary (SPDT).

2
2
2
2
2
2
2
2
2

V8-T2-60 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Plug-In Switches
2.6
Receptacles
2
E50 Heavy-Duty Plug-In Switches, Receptacles
Conduit Cable 2
Description Poles Entrance Length Catalog Number
Surface Mount Surface Mount 2
Conduit entrance, front or rear mounting Single-pole (5 terminal) 1/2 NPT
20 mm


E50RA
E50RA20
2
Two-pole (9 terminal) 1/2 NPT — E50RB 2
3/4 NPT — E50RB34
20 mm — E50RB20 2
Manifold Mount Manifold Mount
Rear wiring entrance instead of conduit hole, Single-pole (5 terminal) — — E50RAM
2
gasket on back for oil tightness
2
Two-pole (9 terminal) — — E50RBM
2
Mini-Connector Mini-Connector 2
Epoxy filled receptacle with pre-wired mini-connector. Single-pole (5 terminal) 5-pin mini-connector — E50RAP5
(The -W version is a wiring scheme typically used
in automotive applications.)
2
— E50RAP5-W

Two-pole (9 terminal) 9-pin mini-connector — E50RBP9


2
Micro Connector Micro-Connector, Straight Female 2
Straight Female
Epoxy filled receptacle with M12 DC micro connector Single-pole (5 terminal) — — E50RAA5
2
2
2
Pre-Wired Cable Pre-Wired Cable 2
Epoxy filled receptacle with pre-wired 16 gauge, Single-pole (5 terminal) 1/2 NPT 8 ft E50RAS
yellow jacketed, type SOOW-A cable. Cable enters
through hole threaded for conduit.
12 ft E50RAS12 2
20 mm
20 ft
8 ft
E50RAS20
E50RA20S
2
12 ft E50RA20S12 2
20 ft E50RA20S20
Two-pole (9 terminal) 1/2 NPT 8 ft E50RBS 2
12 ft E50RBS12
20 ft E50RBS20
2
20 mm 8 ft E50RB20S
2
12 ft E50RB20S12
20 ft E50RB20S20 2
Wiring Diagrams, see Page V8-T2-65.

Note
2
See listing of compatible connector cables on Page V8-T2-62.
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-61


2.6 Limit Switches
E50 Heavy-Duty Plug-In Switches

Compatible Connector Cables


2
Standard Cables 1
2 Current Voltage Number Pin Configuration/Wire Colors
Rating at 600V Style of Pins Gauge Length (Face View Female Shown) Catalog Number
2 Mini-style Mini-Style, Straight Female
Straight Female
2 8A — 5-pin 16 AWG 6 ft (2m) 1-White
2-Red
CSMS5D5CY1602

3-Green
2 4-Orange
5-Black

2 7A — 9-pin 16 AWG 12 ft (4m) 1-Orange


2-Blue
CSMS9D9CY1602

3-Red/Black
2 4-Green/Black
5-White
6-Red
2 7-Green
8-White/Black
9-Black
2
Micro-Style Micro-Style

2 4A — 5-pin,
5-wire
22 AWG 6.0 ft (2m)
1 2
1-Brown
2-White
CSDS5A5CY2202

2
5 3-Blue
3 4 4-Black
5-Green/Yellow

2
2 Accessories

2 E50 Heavy-Duty Plug-In Switch Accessories

2
Description Catalog Number
E50KH1M Adapter Plate

2 Allows E50 to replace Eaton’s 10316 Type LP Surface Mounting Plug-In Limit Switch E50KH1M

2
2
2 E50KH7 Allows E50 to replace Square D Type AW Surface Mounting Non Plug-In Standard Box
Limit Switch
E50KH7

2
2
2
2 Dimensions, see Page V8-T2-67.

2 Note
1 For a full selection of connector cables, see Tab 10, section 10.1.

2
2
2
2
2
2

V8-T2-62 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Plug-In Switches
2.6
E50 Heavy-Duty Plug-In Switch Accessories, continued
Description Catalog Number
2
Adapter Plate, continued
2
E50KH4 Allows E50 to replace National Acme, Type D-1200M, Style 2 Mounting. Denison E50KH4 1
LoxSwitch, Model L-100W, Style 2 Mounting. Square D 9007 Type T, Style B Mounting.
(Adapter plate is 1/8 in thick, with 1/4 in mounting holes.) Namco® long mount. 2
2
2
2
E50KH5 Allows E50 to replace National Acme, Type D-1200M, Style 1 Mounting. Denison E50KH5 1
LoxSwitch, Model L-100W, Style 1 Mounting. Square D 9007 Type T, Style C Mounting.
(Adapter plate is 1/8 in thick, with 1/4 in mounting holes.)
2
2
2
2
E50KH2 Allows E50 to replace Eaton’s 10316 Type LT Non Plug-In Two-Pole Limit Switch E50KH2
2
2
2
2
E50KH10
2
Allows E50 to replace Allen-Bradley 802M Sealed Limit Switch E50KH10

2
2
Adjustable Mounting Plate 2
E50KH3 This is a mounting plate only 5/16 in thick and includes the proper mounting bolts and E50KH3 1
nuts. The slots in the plate allow a maximum horizontal adjustment of 1 in and vertical
adjustment of 1-1/4 in
2
2
2
Conduit Sealing Nut 2
E50KH6 1/2 in oiltight E50KH6
2
2
2
Dimensions, see Page V8-T2-67.

Note
1 Limit switch not included.
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-63


2.6 Limit Switches
E50 Heavy-Duty Plug-In Switches

Technical Data and Specifications


2
E50 Heavy-Duty Plug-In Switches
2 Description Specification

2 Environmental ratings
Material of construction
NEMA 1, 3, 3S, 4, 4X, 6, 6P, 13, IP67
Zinc die cast

2 Switch gasket material Viton


Universal U.S./DIN mounting dimensions 1.16 in (30 mm) x 2.34 in (60 mm)
2 Conduit entrance 1/2 in NPT or 20 mm threading
Contact ratings See below
2 Contact operation Snap action over center mechanism
Contact material Fine silver
2 Maximum frequency of operation 8000 operations per hour

2 Mechanical life
Side rotary 13,000,000 operations minimum

2 Side or top push


Electrical life
10,000,000 operations minimum

2 Single-pole
Two-pole
1,000,000 operations typical at full load
100,000 operations typical at full load

2 Ambient temperature range—standard


Standard without cable 14° to 250°F (–10° to 121°C)

2 Standard with cable 14° to 221°F (–10° to 105°C)


Low temperature without cable –40° to 250°F (–40° to 121°C)
2 Low temperature with cable –40° to 221°F (–40° to 105°C)
Repeat accuracy—standard
2 Side operated Within 0.0012 in
Top operated Within 0.0003 in
2 Side rotary Within 0.0014 in

2
Torque requirements:
Switch body screws 25–30 lb-in

2 Operating head screws


Wire size
14–18 lb-in
Will accept AWG #22–#12, single or stranded wire

2
2 Electrical Data—Maximum Contact Ratings (Same polarity each pole)
Current, Amperes Voltamperes Current, Amperes

2 AC Volts Make Break Cont. 1 Make Break DC Volts


Max. Make
or Break Cont. 1

2 All Switches Except Gravity Return and Indicating Light Versions


NEMA A600 Rating NEMA R300
2 120 60 6 10 7200 720 125 0.22 1.0
240 30 3 10 7200 720 250 0.11 1.0
2 480 15 1.5 10 7200 720 250 0.11 1.0

2 600 12 1.2
Switches with Indicating Lights (LED or Neon)
10 7200 720 250 0.11 1.0

2 NEMA A150 Rating NEMA R150


120 60 6 10 7200 720 125 0.22 1.0
2 Gravity Return Switches—Maximum Contact Ratings
NEMA 6600 Rating—Contacts on same polarity
2 120 30 3 5 3600 360 — — —

2 240
480
15
7.5
1.5
0.75
5
5
3600
3600
360
360





2 600 6 0.60 5 3600 360 — — —

Note
2 1 Thermal rating. Valid only if switch does not have to make or break.

V8-T2-64 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Plug-In Switches
2.6
Circuit Diagrams
2
Standard Assembled Switches and Switch Bodies
Single-Pole 1NO-1NC Two-Pole 2NO-2NC Two-Pole 1NO-2NC 2
2
2
2
Must be same polarity. Parallel wired indicator light.
Same polarity each pole.
Series wired indicator light.
Same polarity each pole.
2
Special Purpose Assembled Switches 2
2
Neutral Position Two-Step (CW, CCW, or Both) Gravity Return

2
2
2
Same polarity, each pole. Same polarity, each pole. Must be same polarity.

Wiring Diagrams 2
Receptacles 1 2
E50RAP5 E50RAP5-W E50RBP9
2
2
2
2
2
2
E50RAA5 E50RAS_ E50RBS_ 2
2
Blue 1 2 Black
3 4
White Brown

2
Green/Yellow
2
GND

Note
2
2
1 The wire colors referenced on these diagrams are those internal to the switch itself.

2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-65


2.6 Limit Switches
E50 Heavy-Duty Plug-In Switches

Dimensions
2 Approximate Dimensions in Inches (mm)

2 Standard E50SB34
Dia. 0.27 (7)
2 Shaft Dia. 0.28 (7) 0.70 (18) 2.46 (63) 2.68 (68)
0.75 (Over Knurl)
0.38 (10) (19) 0.38 (10)

2 0.63 (16) 0.63


(16)
2 0.75
(19)
Dia. 0.20 (5) 4.22
(107)
4.70
(119) 3.61
Front Mtg. Hole 0.24 (92)
4.22
2
1 (6)
0.24 [10-32] Tap 1.06 3.13 3.13 (107) 3.40
(6) 0.38 (10) Deep (27) (79) (79) (86)
Rear Mt. Holes (2)
2 Dia. 0.63 (16)
Conduit Entrance
0.20 3/4-14 NPT
0.50 (13)
2 0.20 (5) Hole for 0.65 Pipe Threads 0.65 (16)
1 Manifold Mtg. Pipe Tap (16) (5) 1
[10-32] Tap 1.31 (33)
1.54 (39) 1.78 (45) 1.54 (39) 0.38 (10) Deep 2.05 (52)

2
Rear Mt. Holes (2)

2 Side Push Operators


Approximate Dimensions in mm [in]
2 Pushbutton Adjustable Pushbutton Roller

2 3
2

2
2
2
2 Maintained Pushbutton

2
2
2
2
2 Top Push Operators
Pushbutton Adjustable Pushbutton Roller
2
2
2
2
2
2
2 Wobble Operators
Notes
1 Can accommodate both U.S., 1.16 (29.4) x 2.34 (59.5) and DIN, 1.18 (30) x 3.26 (60),
See Operators on Page V8-T2-80.
2 mounting dimensions.
2 For E50DS4.
3 For E50DS3.

V8-T2-66 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Plug-In Switches
2.6
Accessories
Approximate Dimensions in mm [in]
2
Adapter Plates 2
E50KH1M E50KH7 E50KH4
2
2
2
2
2
2
E50KH5 E50KH2 E50KH10
2
39

2
[1.54]
29.5
[1.160]

59.5
4.8
[0.19]
5.2 [0.204] THICK
2
[2.340] DIA.

2
(2 HOLES)
13.5
76 [0.531]
[3.00]

2
#10-32 UNC-2B HOLE

2
2
Adjustable Mounting Plate
E50KH3 2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-67


2.7 Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches

Contents
2 E50 Heavy-Duty Factory Sealed 6P+ Switches
Description Page
2 E50 Heavy-Duty Factory Sealed 6P+ Switches
Product Selection
2 Assembled Switches—Standard . . . . . . . . . V8-T2-69
Operating Heads . . . . . . . . . . . . . . . . . . . . . V8-T2-72
2 Switch Bodies . . . . . . . . . . . . . . . . . . . . . . . V8-T2-73
Compatible Connector Cables . . . . . . . . . . V8-T2-74
2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-74

2
Technical Data and Specifications . . . . . . . . . . V8-T2-76
Circuit Diagrams . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-77

2 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
V8-T2-77
V8-T2-78
2 Drawings
Online

2
2
2 E50 Heavy-Duty Factory Sealed 6P+ Switches
2 Product Description Features Standards and Certifications
E50 6P+ Limit Switches by ● Manufactured to take the ● 600V rating, ridge-topped ● UL Listed
2 Eaton’s electrical sector were physical and environmental contacts and wiping action
assure continuity even to
● CSA Certified
specifically designed to abuse (including cutting ● IEC.947.5.1
2 withstand the penetrating
properties of cutting fluids
fluids and chemicals) of
harsh industrial ●
logic level circuits
Factory wired cable
● TUV—E9271605E02
● CE (where shown)
2 and coolants, such as those
used in the automotive ●
environments
Modular, plug-in
features a 350 pound
pullout capacity
industry, as well as extreme components (head and
2 Keyed, four direction head

shock, vibration and switch body) provide positioning. Standard 5°


temperature fluctuations. The application flexibility, pre-travel and 90° total
2 one-piece, epoxy filled switch
body is prewired at the
reduced inventory and less travel
downtime ● 24–120 Vac/dc LED and
2 factory to ensure leak-proof,
submersible performance.
● Chemical resistant Viton 120 Vac neon indicating DANGER
gaskets, seals and boots lights available
This unique construction
2 positively stops fluid from
are standard, and so are
captive, posi-drive screws
● Rotary heads are field
THIS SENSOR IS NOT A
SAFETY DEVICE AND IS NOT
finding its way to any and all convertible CW, CCW, or INTENDED TO BE USED AS A
2 critical connections.
● A special tertiary seal on
the switch body prevents
both, without special tools SAFETY DEVICE. This sensor
is designed only to detect
2 Our 6P+ switches can be fluid from entering even
and read certain data in an
ordered in separate when the operating head is
electronic manner and
components or as complete not attached
2 assembled devices. They are
perform no use apart from
that, specifically no safety-
available with prewired 16
related use. This sensor
2 AWG cables or mini-
connectors. Standard and
product does not include
self-checking redundant
2 custom cable lengths are
available. As part of the E50
circuitry, and the failure of
this sensor product could
line, the 6P+ switches use
2 the same operating heads as
cause either an energized
or de-energized output
the standard E50 plug-in
2 models to reduce the
condition, which could result
in death, serious bodily
components you need to
injury, or property damage.
2 inventory.

2
2 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
For the most current information
2 on this product, visit our Web site:
www.eaton.com
For Application Assistance in the U.S. and Canada
call 1-800-426-9184.

V8-T2-68 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches
2.7
Product Selection
2
Assembled Switches—Standard
Connection is by 8 ft cable 1. 2

Assembled Switch E50 Heavy-Duty Factory Sealed 6P+ Switches, Assembled—Standard 2


2
2
2
Single-Pole
LED Neon
Two-Pole
LED Neon
2
2
Lever sold separately Indicating Light: None (24–120 Vac/dc) (120 Vac) None (24–120 Vac/dc) (120 Vac)
E50SA6P E50SAL6P E50SAN6P E50SB6P E50SBL6P E50SBN6P

2
Switch Body: 1NO-1NC 1NO-1NC 1NO-1NC 2NO-2NC 2NO-2NC 2NO-2NC
Assembled Switch Assembled Switch
2

2
Operating Head Type Description Catalog Number Catalog Number
Side Rotary Side Rotary (requires an operating lever, see Page V8-T2-80)
Standard spring
return—E50DR1 3
E50AR16P E50ALR16P E50ANR16P E50BR16P E50BLR16P E50BNR16P 2
Low force spring E50AL16P E50ALL16P E50ANL16P E50BL16P E50BLL16P E50BNL16P 2
return—E50DL1 3
2
Maintained two- E50AM16P E50ALM16P E50ANM16P E50BM16P E50BLM16P E50BNM16P
position—E50DM1
2
Side Pushbutton
Spring Return Spring return— E50AS16P E50ALS16P E50ANS16P E50BS16P E50BLS16P E50BNS16P
2
E50DS1
2
2
Adjustable Spring
Return
Adjustable spring
return—E50DS2
E50AS26P E50ALS26P E50ANS26P E50BS26P E50BLS26P E50BNS26P 2
2
2
Circuit Diagrams, see Page V8-T2-77.
2
Notes
1 Connection options (add the code suffix from the table below to the end of the catalog number): 2
Option Catalog Number Code Suffix
Mini-connector 4 Single-pole (5-pin mini-connector) CSMS5D5CY1602 C
2
Two-pole (9-pin mini-connector) CSMS9D9CY1602 C
2
Cable connection 12 ft cable length (standard) — 12
20 ft cable length (standard) — 20 2
Other lengths (special order) — Length in ft

2 For operating head specifications, see Page V8-T2-72.


2
2
3 CW (clockwise) and CCW (counterclockwise) operation, easily convertible to CW only or CCW only operation.
4 For a full selection of connector cables, see Tab 10, section 10.1.

2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-69


2.7 Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches

Connection is by 8 ft cable 1.
2
E50 Heavy-Duty Factory Sealed 6P+ Switches, Assembled—Standard, continued
2 Assembled Switch

2
2
2 Single-Pole Two-Pole

2 Lever sold separately Indicating Light: None


LED
(24–120 Vac/dc)
Neon
(120 Vac) None
LED
(24–120 Vac/dc)
Neon
(120 Vac)

2 Switch Body:
E50SA6P
1NO-1NC
E50SAL6P
1NO-1NC
E50SAN6P
1NO-1NC
E50SB6P
2NO-2NC
E50SBL6P
2NO-2NC
E50SBN6P
2NO-2NC

2 Operating Head Type 2 Description


Assembled Switch
Catalog Number
Assembled Switch
Catalog Number

2 Side Push Roller Side Push Roller


Spring return— E50AS36P E50ALS36P E50ANS36P E50BS36P E50BLS36P E50BNS36P

2
E50DS3 3

2
2
Side Pushbutton Side Pushbutton
Maintained— E50AH16P E50ALH16P E50ANH16P E50BH16P E50BLH16P E50BNH16P
E50DH1
2
2
2
Top Pushbutton
Spring Return Spring return— E50AT16P E50ALT16P E50ANT16P E50BT16P E50BLT16P E50BNT16P
E50DT1
2
2
2 Adjustable Spring Adjustable spring E50AT26P E50ALT26P E50ANT26P E50BT26P E50BLT26P E50BNT26P
Return return—E50DT2
2
2
2
Circuit Diagrams, see Page V8-T2-77.
2 Notes
1 Connection options (add the code suffix from the table below to the end of the catalog number):

2 Option Catalog Number Code Suffix

2 Mini-connector 4 Single-pole (5-pin mini-connector) CSMS5D5CY1602 C


Two-pole (9-pin mini-connector) CSMS9D9CY1602 C
2 Cable connection 12 ft cable length (standard) — 12
20 ft cable length (standard) — 20
2 Other lengths (special order) — Length in ft

2 2
3
For operating head specifications, see Page V8-T2-72.
Roller can be converted in the field between horizontal and vertical.

2
4 For a full selection of connector cables, see Tab 10, section 10.1.

2
2

V8-T2-70 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches
2.7
Connection is by 8 ft cable 1.
2
E50 Heavy-Duty Factory Sealed 6P+ Switches, Assembled—Standard, continued
Assembled Switch
2
2
2
Single-Pole Two-Pole 2
Lever sold separately Indicating Light: None
LED
(24–120 Vac/dc)
Neon
(120 Vac) None
LED
(24–120 Vac/dc)
Neon
(120 Vac) 2
Switch Body:
E50SA6P
1NO-1NC
E50SAL6P
1NO-1NC
E50SAN6P
1NO-1NC
E50SB6P
2NO-2NC
E50SBL6P
2NO-2NC
E50SBN6P
2NO-2NC 2
Operating Head Type 2 Description
Assembled Switch
Catalog Number
Assembled Switch
Catalog Number 2
2
Top Push Roller Top Push Roller
Spring return— E50AT36P E50ALT36P E50ANT36P E50BT36P E50BLT36P E50BNT36P

2
E50DT3

2
Wobble Head, Wobble Head, Spring Return (requires a wobble operator, see Page V8-T2-80) 2
Spring Return
2
Standard duty— E50AW16P E50ALW16P E50ANW16P E50BW16P E50BLW16P E50BNW16P
E50DW1

Heavy-duty E50AW26P E50ALW26P E50ANW26P E50BW26P E50BLW26P E50BNW26P 2


high strength
steel— E50DW2 2
Circuit Diagrams, see Page V8-T2-77.

Notes
2
1 Connection options (add the code suffix from the table below to the end of the catalog number):
2
Option Catalog Number Code Suffix
Mini-connector 3 Single-pole (5-pin mini-connector) CSMS5D5CY1602 C 2
Double-pole (9-pin mini-connector) CSMS9D9CY1602 C
Cable connection 12 ft cable length (standard) — 12 2
20 ft cable length (standard)
Other lengths (special order)


20
Length in ft
2
2 For operating head specifications, see Page V8-T2-72. 2
3 For a full selection of connector cables, see Tab 10, section 10.1.
2
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-71


2.7 Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches

Operating Heads
2
E50 Heavy-Duty Factory Sealed 6P+ Switches, Operating Heads
2 Operating Temperature 1
Travel to Travel to Force to Minimum
2 Description
Operate
Contacts
Reset
Contacts
Total
Travel
Operate
Contacts
Return
Force Without Cable
With
Pre-wired Cable
Catalog
Number

2 Side Rotary Side Rotary (requires an operating lever, see Page V8-T2-80)
Standard spring return 2 5° 2° 90° 3 in-lbs 4.5 in-oz 10° to 200°F 10° to 200°F E50DR1
2 Low temperature 5° 2° 90° 3 in-lbs 4.5 in-oz
(–12° to 94°C) 3 (–12° to 94°C) 3
–40° to 175°F –31° to 175°F E50DR19

2
spring return 2 (–40° to 79°C) (–34° to 79°C)
Low force spring return 2 15° 6° 90° 1.5 in-lbs 2.5 in-oz 10° to 200°F 10° to 200°F E50DL1
(–12° to 94°C) 3 (–12° to 94°C) 3
2 Maintained two-position 50° 50° 90° 3 in-lbs — 14° to 200°F 14° to 200°F E50DM1
(–10° to 94°C) (–10° to 94°C)
2 Side Pushbutton

2 Spring Return Spring return 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14° to 200°F
(–10° to 94°C)
14° to 200°F
(–10° to 94°C)
E50DS1

2
2
Adjustable Spring Adjustable spring return 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14° to 200°F 14° to 200°F E50DS2
2 Return (–10° to 94°C) (–10° to 94°C)

2
2
Side Push Roller Side Push Roller
2 Spring return 4 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14° to 200°F 14° to 200°F E50DS3 5
(–10° to 94°C) (–10° to 94°C)

2 0.065 in 0.030 in 0.250 in 4 lbs 8 oz 14° to 200°F 14° to 200°F E50DS4 5


(–10° to 94°C) (–10° to 94°C)
2 Side Pushbutton Side Pushbutton

2 Maintained 0.200 in 0.130 in 0.320 in 5 lbs 5 lbs 14° to 200°F


(–10° to 94°C)
14° to 200°F
(–10° to 94°C)
E50DH1

2
2 Top Pushbutton
Spring Return Spring return 0.040 in 0.020 in 0.280 in 4 lbs 8 oz 14° to 250°F 14° to 221°F E50DT1
2 (–10° to 121°C) (–10° to 105°C)

2
2
Adjustable Spring Adjustable spring return 0.040 in 0.020 in 0.280 in 4 lbs 8 oz 14° to 250°F 14° to 221°F E50DT2
2 Return (–10° to 121°C) (–10° to 105°C)

2
2
2
Notes
1 Temperature ranges below 32°F (0°C) are based on absence of freezing moisture or water.
2 CW (clockwise) and CCW (counterclockwise) operation, easily convertible to CW only or CCW only operation.

2 3 For CW and CCW operation. For CW only or CCW only operation, high temperature limit increases to 250°F (121°C) without cable, and 221°F (105°C)

with pre-wired cable.

2
4 Roller can be converted in the field between horizontal and vertical.
5 Roller shaft is 0.38 in (9.5 mm) longer on E50DS4, see Dimensions on Page V8-T2-78.

V8-T2-72 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches
2.7
E50 Heavy-Duty Factory Sealed 6P+ Switches, Operating Heads, continued
Operating Temperature 1
2
Travel to Travel to Force to Minimum

Description
Operate
Contacts
Reset
Contacts
Total
Travel
Operate
Contacts
Return
Force Without Cable
With
Pre-Wired Cable
Catalog
Number
2
Top Push Roller Top Push Roller
2
Spring return 0.040 in 0.020 in 0.280 in 4 lbs 8 oz 14° to 250°F 14° to 221°F E50DT3
(–10° to 121°C) (–10° to 105°C)
2
2
Wobble Head, Wobble Head, Spring Return (requires a wobble operator, see Page V8-T2-80)
2
Spring Return
Standard duty 10° 6° 15° 2 in-lbs 2.4 in-oz 14° to 250°F
(–10° to 121°C)
14° to 221°F
(–10° to 105°C)
E50DW1
2
Heavy-duty high strength steel 10° 6° 15° 2 in-lbs 2.4 in-oz 14° to 250°F 14° to 221°F E50DW2 2
(–10° to 121°C) (–10° to 105°C)
2
Circuit Diagrams, see Page V8-T2-77.
2
Switch Bodies
2
E50 Heavy-Duty Factory Sealed 6P+, Switch Bodies
Cable 2
Circuit Switch Body Construction Length Catalog Number

Pre-Wired Cable Pre-Wired Cable 2


2
Single-pole 1NO-1NC Without indicating light 8 ft E50SA6P
12 ft E50SA6P12
20 ft E50SA6P20
2
With LED indicating light 24 –120 Vac/dc 8 ft E50SAL6P
12 ft E50SAL6P12 2
20 ft E50SAL6P20
With neon indicating light 120 Vac 8 ft E50SAN6P 2
12 ft
20 ft
E50SAN6P12
E50SAN6P20
2
Two-pole 2NO-2NC Without indicating light 8 ft E50SB6P 2
12 ft E50SB6P12
20 ft E50SB6P20 2
2
With LED indicating light 24–120 Vac/dc 8 ft E50SBL6P
12 ft E50SBL6P12
With neon indicating light 120 Vac 8 ft E50SBN6P
2
12 ft E50SBN6P12
20 ft E50SBN6P20 2
Mini-Connector Mini-Connector
Single-pole 1NO-1NC Without indicating light normal wiring — E50SA6PC 2
2
Without indicating light alternate wiring — E50SA6PC-W
With LED indicating light 24–120 Vac/dc — E50SAL6PC
With neon indicating light 120 Vac — E50SAN6PC
2
Two-pole 2NO-2NC Without indicating light — E50SB6PC
With LED indicating light 24–120 Vac/dc — E50SBL6PC 2
With neon indicating light 120 Vac — E50SBN6PC

Notes
2
1
See listing of compatible connector cables on Page V8-T2-74.
Temperature ranges below 32°F (0°C) are based on absence of freezing moisture or water.
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-73


2.7 Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches

Compatible Connector Cables


2
Standard Cables 1
2 Current Voltage Number Pin Configuration/Wire Colors
Rating at 600V Style of Pins Gauge Length (Face View Female Shown) Catalog Number
2 Mini-Style, Mini-Style, Straight Female
Straight Female
2 8A — 5-pin 16 AWG 6 ft (2m) 1-White
2-Red
CSMS5D5CY1602

3-Green
2 4-Orange
5-Black

2 7A — 9-pin 16 AWG 12 ft (4m) 1-Orange


2-Blue
CSMS9D9CY1602

3-Red/Black
2 4-Green/Black
5-White
6-Red
2 7-Green
8-White/Black
9-Black
2
2 Accessories
2 E50 Heavy-Duty Factory Sealed 6P+ Switch Accessories
2 Catalog Number
E50KH1M Adapter Plate
2 Allows E50 to replace Eaton’s 10316 Type LP Manifold Mounting Plug-In Limit Switch E50KH1M

2
2
2 E50KH7 Allows E50 to replace Square D Type AW Surface Mounting Non Plug-In Standard Box E50KH7
Limit Switch
2
2
2
2
Dimensions, see Page V8-T2-78.
2 Note

2
1 For a full selection of connector cables, see Tab 10, section 10.1.

2
2
2
2
2
2
2
2

V8-T2-74 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches
2.7
E50 Heavy-Duty Factory Sealed 6P+ Switch Accessories, continued
Catalog Number
2
Adapter Plate, continued
2
E50KH4 Allows E50 to replace National Acme, Type D-1200M, Style 2 Mounting. Denison E50KH4 1
LoxSwitch, Model L-100W, Style 2 Mounting. Square D 9007 Type T, Style B Mounting.
(Adapter plate is 1/8 in thick, with 1/4 in mounting holes.) Namco® long mount. 2
2
2
2
E50KH5 Allows E50 to replace National Acme, Type D-1200M, Style 1 Mounting. Denison E50KH5 1
LoxSwitch, Model L-100W, Style 1 Mounting. Square D 9007 Type T, Style C Mounting.
(Adapter plate is 1/8 in thick, with 1/4 in mounting holes.)
2
2
2
2
E50KH2 Allows E50 to replace Eaton’s 10316 Type LT Non Plug-In Two-Pole Limit Switch E50KH2
2
2
2
2
E50KH10
2
Allows E50 to replace Allen-Bradley 802M Sealed Limit Switch E50KH10

2
2
Adjustable Mounting Plate 2
E50KH3 This is a mounting plate only 5/16 in thick and includes the proper mounting bolts and E50KH3 1
nuts. The slots in the plate allow a maximum horizontal adjustment of 1 in and vertical
adjustment of 1-1/4 in
2
2
2
Conduit Sealing Nut 2
E50KH6 1/2 in oiltight E50KH6
2
2
2
Dimensions, see Page V8-T2-78.

Note
1 Limit switch not included.
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-75


2.7 Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches

Technical Data and Specifications


2
E50 Heavy-Duty Factory Sealed 6P+ Switches
2 Description Specification

2 Environmental ratings
Material of construction
NEMA 1, 3, 3S, 4, 4X, 6, 6P, 13, IP67, IP69K
Zinc die cast

2 Switch gasket material Viton


Universal U.S./DIN mounting dimensions 1.16 in (30 mm) x 2.34 in (60 mm)
2 Conduit entrance 1/2 in NPT or 20 mm threading
Contact ratings See below
2 Contact operation Snap action over center mechanism
Contact material Fine silver
2 Maximum frequency of operation 8000 operations per hour

2 Mechanical life
Side rotary 13,000,000 operations minimum

2 Side or top push


Electrical life
10,000,000 operations minimum

2 Single-pole
Double-pole
1,000,000 operations typical at full load
100,000 operations typical at full load

2 Ambient temperature range—standard


Standard without cable 14° to 250°F (–10° to 121°C)

2 Standard with cable 14° to 221°F (–10° to 105°C)


Low temperature without cable –40° to 250°F (–40° to 121°C)
2 Low temperature with cable –40° to 221°F (–40° to 105°C)
Repeat accuracy—standard
2 Side operated Within 0.0012 in
Top operated Within 0.0003 in
2 Side rotary Within 0.0014 in

2
Torque requirements
Operating head screws 14–18 lb-in

2
2 Electrical Data—Maximum Contact Ratings (Same polarity each pole)
Current, Amperes Voltamperes Current, Amperes

2 AC Volts Make Break Cont. 1 Make Break DC Volts


Max. Make
or Break Cont. 1

2 All Switches Except Gravity Return and Indicating Light Versions


NEMA A600 Rating NEMA R300

2 120 60 6 10 7200 720 125 0.22 1.0


240 30 3 10 7200 720 250 0.11 1.0
2 480 15 1.5 10 7200 720 250 0.11 1.0

2
600 12 1.2 10 7200 720 250 0.11 1.0
Switches with Indicating Lights (LED or Neon)

2 NEMA A150 Rating NEMA R150


120 60 6 10 7200 720 125 0.22 1.0
2 Note
1 Thermal rating. Valid only if switch does not have to make or break.

2
2
2
2
2

V8-T2-76 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches
2.7
Circuit Diagrams 1
2
Standard Assembled Switches
Single-Pole 1NO-1NC Two-Pole 2NO-2NC 2
2
2
2
2
2
Must be same polarity. Same polarity, each pole.

Switch Bodies
Pre-Wired Cable— Pre-Wired Cable— 2
Single-Pole 1NO-1NC Two-Pole 2NO-2NC
E50SA6P_ E50SAL6P_ E50SB6P_ E50SBL6P_
2
2
2
2
2
2
Wiring Diagrams 1
Mini-Connector—Single-Pole 1NO-1NC 2
E50SA6PC E50SA6PC-W E50SAL6PC/E50SAN6PC
2
2
2
2
2
2
Mini-Connector—Two-Pole 2NO-2NC
E50SB6PC E50SBL6PC/E50SBN6PC
2
2
2
2
2
2
2
Note 2
1 The wire colors referenced on these diagrams are those internal to the switch itself.
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-77


2.7 Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches

Dimensions
2 Approximate Dimensions in Inches (mm)

2 Standard

2 6P+ Limit Switch with Rotary Operating Head


2.25 (57.0)
0.81

2 1.44
(37.0)
(21.0)

0.75

2
0.75
(19.0) (19.0)
0.31 0.37 (9.4)
(8.0)

2 Dia. 0.20 (5.0)


Front Mtg. Hole 4.22
(107.0)
3.13

2
1 2.74
(79.0)
(69.5)

0.45

2 0.24
(6.2)
(11.4)

Conduit Entrance

2 1.13 0.50 Pipe Tap 0.20


(28.7) (5.2)
1.58 (40.1) 1 [10-32] Tap
0.99 (25.0) 1.54 0.38 (10.0) Deep

2 (39.0) Rear Mtg. Holes (2)

2 Side Push Operators


Approximate Dimensions in mm [in]
2 Pushbutton Adjustable Pushbutton Roller

2
2

2
2
2
2 Maintained Pushbutton

2
2
2
2 Top Push Operators
2 Pushbutton Adjustable Pushbutton Roller

2
2
2
2
2
2 Notes
Wobble Operators
2
1 Can accommodate both U.S., 1.16 (29.4) x 2.34 (59.5) and DIN, 1.18 (30.0) x 3.26 (60.0),
See Operators on Page V8-T2-80. mounting dimensions.
2 For E50DS4.

2 3 For E50DS3.

V8-T2-78 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
E50 Heavy-Duty Factory Sealed 6P+ Switches
2.7
Accessories
Approximate Dimensions in mm [in]
2
Adapter Plates 2
E50KH1M E50KH7 E50KH4
2
2
2
2
2
2
E50KH5 E50KH2 E50KH10
2
39

2
[1.54]
29.5
[1.160]

59.5
4.8
[0.19]
5.2 [0.204] THICK
2
[2.340] DIA.

2
(2 HOLES)
13.5
76 [0.531]
[3.00]

2
#10-32 UNC-2B HOLE

2
2
Adjustable Mounting Plate
E50KH3 2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-79


2.8 Limit Switches
Operators

Contents
2 Operators
Description Page
2 Operators
Product Selection
2 Roller Type Operators . . . . . . . . . . . . . . . . . V8-T2-81
Rod Type Operators . . . . . . . . . . . . . . . . . . V8-T2-83
2 Wobble Type Operators . . . . . . . . . . . . . . . V8-T2-84
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-84
2 Drawings

2
Online

2
2
2
2
2 Operators
2 Product Description Features
DANGER
The Operators presented ● Wide variety of operator
2 here are used with Eaton’s types for rotary and THIS SENSOR IS NOT A
SAFETY DEVICE AND IS NOT
E50 Plug-In and 6P+ limit wobble style limit switches
2 switches, as well as our
10316 rotary type limit
● Rollers and rods available INTENDED TO BE USED AS A
SAFETY DEVICE. This sensor
in metal and nonmetal
is designed only to detect
2 switches. A wide variety of
styles and sizes are available
contact surfaces
and read certain data in an
to provide optimum electronic manner and
2 performance for nearly any perform no use apart from
application. that, specifically no safety-
2 related use. This sensor
product does not include
2 self-checking redundant
circuitry, and the failure of
this sensor product could
2 cause either an energized
or de-energized output
2 condition, which could result
in death, serious bodily
2 injury, or property damage.

2
2
2
2
2
2
2
2 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
For the most current information
2 on this product, visit our Web site:
www.eaton.com
For Application Assistance in the U.S. and Canada
call 1-800-426-9184.

V8-T2-80 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Operators
2.8
Product Selection
2
Roller Type Operators
For rotary head switches: E50 Plug-In, E50 6P+, and 10316. 2
Note: Only operators with Nylatron rods or rollers should be used with explosion-proof limit switches.
2
Operators—Roller Type
Approximate Dimensions in Inches (mm)
2
Minimum

Roller Type
Required
Return Torque 1
A
Lever Length 2
B
Roller Diameter
C
Roller Width D E F
Catalog
Number 2
E50KL200 Standard Roller (Stainless Steel)
2
Metal 0.62 in-oz 0.88 (22.2) 0.75 (19.0) 0.32 (8.1) 0.31 (7.9) 0.20 (5.1) 0.24 (6.1) E50KL39
Metal 0.95 in-oz 1.38 (34.9) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL40 2
Ball bearing 0.77 in-oz 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8) E50KL531
Nylatron 0.53 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL200 2
E50KL355
2
Metal 1.10 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL355
Nylatron 0.96 in-oz 1.50 (38.1) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) E50KL377
Without roller 0.32 in-oz 1.50 (38.1) — — 0.34 (8.6) — — E50KL32
2
Ball bearing 1.10 in-oz 2.00 (50.8) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8) E50KL552
Nylatron 0.71 in-oz 2.00 (50.8) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL546 2
E50KL377
Metal 1.50 in-oz 2.00 (50.8) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL549
Nylatron 1.45 in-oz 2.00 (50.8) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) E50KL572 2
Ball bearing
Nylatron
1.50 in-oz
1.00 in-oz
2.50 (63.5)
2.50 (63.5)
0.69 (17.5)
0.75 (19.0)
0.25 (6.4)
0.32 (8.1)
0.34 (8.6)
0.34 (8.6)
0.05 (1.3)
0.13 (3.3)
0.11 (2.8)
0.17 (4.3)
E50KL553
E50KL547
2
Metal 2.00 in-oz 2.50 (63.5) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL550 2
Nylatron 1.80 in-oz 2.50 (63.5) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) E50KL573
2
E50KL554
Nylatron 1.40 in-oz 2.50 (63.5) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.11 (2.8) 0.17 (4.3) E50KL575
Ball bearing 1.80 in-oz 3.00 (76.2) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8) E50KL554
Nylatron 1.30 in-oz 3.00 (76.2) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL548
2
Metal 2.50 in-oz 3.00 (76.2) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3) E50KL551
2
Nylatron 2.30 in-oz 3.00 (76.2) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1) E50KL574
Nylatron 1.80 in-oz 3.00 (76.2) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.11 (2.8) 0.17 (4.3) E50KL576 2
E50KL580 Dimensions, see Page V8-T2-84.
Roller On Reverse Side (Stainless Steel) 2
Ball bearing
Nylatron
0.77 in-oz
0.53 in-oz
1.50 (38.1)
1.50 (38.1)
0.69 (17.5)
0.75 (19.0)
0.25 (6.4)
0.32 (8.1)
0.34 (8.6)
0.34 (8.6)
0.18 (4.6)
0.27 (6.9)
0.24 (6.1)
0.31 (7.9)
E50KL580
E50KL310
2
Metal 1.10 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.27 (6.9) 0.31 (7.9) E50KL579 2
E50KL24 Nylatron 0.96 in-oz 1.50 (38.1) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.23 (5.8) 0.31 (7.9) E50KL536
Offset Inboard Roller (Stainless Steel) 2
Nylatron 0.65 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.03 (0.8) — — E50KL24
2
Metal 1.20 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.03 (0.8) — — E50KL25

Ball bearing 0.90 in-oz 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.04 (1.0) — — E50KL26
2
E50KL27
Offset Outboard Roller (Stainless Steel) 2
2
Nylatron 0.65 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.03 (0.8) — — E50KL27
Metal 1.20 in-oz 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.03 (0.8) — — E50KL28
Ball bearing 0.90 in-oz 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.04 (1.0) — — E50KL29 2
Nylatron 1.10 in-oz 1.50 (38.1) 0.75 (19.0) 1.00 (25.4) — — — E50KL30
Dimensions, see Page V8-T2-85. 2
Notes
1 Caution: When selecting lever, the minimum required return torque of lever should not exceed minimum
2
return force available in operating head as given in operating head specifications.
2 Length from the operating shaft axis to the roller axis (or to the tip for non-roller operators). 2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-81


2.8 Limit Switches
Operators

Note: Only operators with Nylatron rods or rollers should be used with explosion-proof limit switches.
2
Operators—Roller Type, continued
2 Minimum Approximate Dimensions in Inches (mm)
Required A B C Catalog
2 Roller Type Return Torque 1 Lever Length 2 Roller Diameter Roller Width D E F Number
E50KL532 Bantam Lever
2 Metal 0.45 in-oz 0.69 (17.5) 0.85 (22.0) 0.18 (4.6) — — — E50KL532

2
2 E50KL340 Precision Adjustment

2 Nylatron 0.65 in-oz 0.69 (17.5)


Roller length:
0.75 (19.0) 0.32 (8.1) 0.48 (12.2) 0.24 (6.1) 0.28 (7.1) E50KL340

Metal 1.20 in-oz 1.50 (38.1) 3 0.75 (19.0) 0.32 (8.1) 0.48 (12.2) 0.24 (6.1) 0.28 (7.1) E50KL465
2 Ball bearing 0.90 in-oz 0.69 (17.5) 0.25 (6.4) 0.48 (12.2) 0.16 (4.1) 0.22 (5.6) E50KL535

2 E50KL201 Dimensions, see Page V8-T2-85.


Adjustable Roller (Stainless Steel)
2 Ball bearing 2.50 in-oz 4 1.0 (25.4) to 0.69 (17.5) 0.25 (6.4) 0.23 (5.8) 0.30 (7.6) — E50KL539
3.75 (95.2) 5
2
Nylatron 1.90 in-oz 4 0.75 (19.0) 0.32 (8.1) 0.29 (7.4) 0.33 (8.4) — E50KL201
0.75 (19.0) 0.32 (8.1) 0.29 (7.4) 0.33 (8.4) — E50KL201SPL 6
E50KL537
2 Metal 3.40 in-oz 4
4
0.75 (19.0) 0.32 (8.1) 0.29 (7.4) 0.33 (8.4) — E50KL538
Nylatron 1.90 in-oz 0.75 (19.0) 0.50 (12.7) 0.46 (11.6) 0.48 (12.2) — E50KL599
2 Nylatron 3.10 in-oz 4 0.75 (19.0) 1.00 (25.4) 0.90 (22.9) 0.95 (24.1) — E50KL537
Large Nylatron 4.50 in-oz 4 0.5 (12.7) to 4.00 (102.0) 0.11 (2.8) 0.11 (2.8) 0.19 (4.8) — E50KL598
2 3.25 (82.6)
Without roller 1.20 in-oz 4 0.5 (12.7) to — — — — — E50KL31
2 3.75 (95.2)
Nylatron 2.50 in-oz 4 1.63 (41.3) to 1.50 (38.1) 0.29 (7.4) 0.26 (6.6) 0.32 (8.1) — E50KL443
2 3.75 (95.2) 5
Dimensions, see Page V8-T2-86.
2
Operators—Roller Type, continued
2 Minimum Approximate Dimensions in Inches (mm)
Required
2 Return A B C Catalog
Roller Type Torque 1 Lever Length 2 Roller Diameter Roller Width D E F G Number

2 E50KL545 Fork Lever—Both Rollers on One Side


Ball bearing — 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.08 (2.0) 0.14 (3.6) — — E50KL545
2 Nylatron — 0.75 (19.0) 0.32 (8.1) 0.16 (4.1) 0,20 (5.1) — — E50KL204

2 Metal — 0.75 (19.0) 0.32 (8.1) 0.16 (4.1) 0,20 (5.1) — — E50KL544
Nylatron — 0.75 (19.0) 1.00 (25.4) 0.84 (21.3) 0.88 (22.4) — — E50KL543
2 E50KL542 Fork Lever—One Roller Outside, One Inside
Ball bearing — 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.08 (2.0) 0.14 (3.6) 0.64 (16.3) 0.70 (17.8) E50KL542
2 Nylatron — 0.75 (19.0) 0.32 (8.1) 0.16 (4.1) 0.20 (5.1) 0.73 (18,5) 0.77 (19.6) E50KL203

2 Metal — 0.75 (19.0) 0.32 (8.1) 0.16 (4.1) 0.20 (5.1) 0.73 (18,5) 0.77 (19.6) E50KL541

2 Dimensions, see Page V8-T2-86.

Notes
2 1 Caution: When selecting lever, the minimum required return torque of lever should not exceed minimum

return force available in operating head as given in operating head specifications.

2
2 Length from the operating shaft axis to the roller axis (or to the tip for non-roller operators).
3 Maximum length dimension between operating shaft axis to roller axis for comparison.

Precision adjustable to lesser dimensions.


2 4 Applies when lever is extended to the maximum dimension.
5 By reassembling lever, minimum length can be reduced another 0.5 in (12.7 mm).

2
6 High-grade stainless steel.

V8-T2-82 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Operators
2.8
Rod Type Operators
For rotary head switches: E50 Plug-In, E50 6P+, and 10316. 2
Note: Only operators with Nylatron rods or rollers should be used with explosion-proof limit switches. 2
Operators—Rod Type 2
Approximate Dimensions in Inches (mm)
Minimum
Required
A
Rod Length B Catalog
2
Rod Type Return Torque 1 (Maximum) 2 Rod Diameter Number
Nylon/Metal Adjustable Rod
2
Nylon 0.40 in-oz 3 5.50 (140.0) 0.19 (4.8) E50KL399
2
Metal 0.92 in-oz 3 0.12 (3.2) E50KL202
Metal 2.20 in-oz 3 8.75 (222.0) Rod size (square):
0.12 (3.2) x 0.12 (3.2)
E50KL581 2
Metal/Steel Stainless steel 7.00 in-oz 3 9.00 (229.0) 0.19 (4.8) E50KL220
2
Bendable steel 5.00 in-oz 3 12.00 (305.0) 0.12 (3.2) E50KL226
Clamps for Adjustable Rods (Rod not included) 2
Clamp for …
0.19 (4.8) diameter rods E50KL35 2
2
0.12 (3.2) diameter rods E50KL36
0.25 (6.4) diameter rods E50KL41
Dimensions, see Page V8-T2-87.
2
Operators—Rod Type, continued 2
Minimum Approximate Dimensions in Inches (mm)

Rod Type
Required
Return Torque 1
A
Rod Length 2
B
Rod Diameter C D
Catalog
Number
2
Nylon/Steel Spring Rod 2
Nylon 3.50 in-oz — — — — E50KL556

Stainless steel 2.80 in-oz — — — — E50KL421


2
Nylon Covered Wire Adjustable Wire 2
Nylon covered wire 1.50 in-oz 3 — — — — E50KL533
2
2
Nylatron Adjustable Wide Roller Lever
Nylatron 4.50 in-oz 3 — — — — E50KL37 2
2
Nylatron Nylatron Loop 2
Nylatron 0.40 in-oz 6.00 (152.0) 0.158 (4.0) — — E50KL142
2
2
Zinc-Plated Steel Eye Bolt
Zinc-plated steel 0.53 in-oz 150.00 (38.1) 0.1875 (4.8) 0.52 (13.1) 0.24 (8.6) E50KL33 2
Loop ID: 0.375 (9.5)
2
2
Dimensions, see Page V8-T2-87.
2
Notes
1 Caution: When selecting lever, the minimum required return torque of lever should not exceed minimum

return force available in operating head as given in operating head specifications.


2
2
2 Length from the operating shaft axis to tip.
3 Applies when lever is extended to the maximum dimension.

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-83


2.8 Limit Switches
Operators

Wobble Type Operators


2 For E50DW1 and E50DWZ Operator Heads on E50 Plug-In and E50 6P+ Switches.

2 Note: Only operators with Nylatron rods or rollers should be used with explosion-proof limit switches.

2 Operators—Wobble Type
Wobble Type Catalog Number
2 E50KW2 Nylon Rod
E50KW2
2
2
E50KW3 Stainless Steel Rod
2 E50KW3

2
E50KW4 Coil Spring
2 E50KW4

2
Dimensions, see Page V8-T2-88.
2
2 Dimensions
2 Roller Type Operators

2 C B Standard Roller
Approximate Dimensions in Inches (mm)
2 A B C
F Catalog Number Lever Length 1 Roller Diameter Roller Width D E F
2 E A
E50KL39 0.88 (22.2) 0.75 (19.0) 0.32 (8.1) 0.31 (7.9) 0.20 (5.1) 0.24 (6.1)

2
E50KL40 1.38 (34.9) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3)
D E50KL531 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8)

2 0.44
(11)
0.67
(17)
E50KL200 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3)
E50KL355 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3)
2 E50KL377 1.50 (38.1) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1)
E50KL32 1.50 (38.1) — — 0.34 (8.6) — —
2 E50KL552 2.00 (50.8) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8)

2 E50KL546
E50KL549
2.00 (50.8)
2.00 (50.8)
0.75 (19.0)
0.75 (19.0)
0.32 (8.1)
0.32 (8.1)
0.34 (8.6)
0.34 (8.6)
0.13 (3.3)
0.13 (3.3)
0.17 (4.3)
0.17 (4.3)

2 E50KL572 2.00 (50.8) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1)
E50KL553 2.50 (63.5) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8)
2 E50KL547 2.50 (63.5) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3)

2
E50KL550 2.50 (63.5) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3)
E50KL573 2.50 (63.5) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1)

2 E50KL575 2.50 (63.5) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.11 (2.8) 0.17 (4.3)
E50KL554 3.00 (76.2) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.05 (1.3) 0.11 (2.8)

2 E50KL548 3.00 (76.2) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3)
E50KL551 3.00 (76.2) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.13 (3.3) 0.17 (4.3)
2 E50KL574 3.00 (76.2) 0.75 (19.0) 1.00 (25.4) 0.34 (8.6) 0.83 (21.1) 0.83 (21.1)

2
E50KL576 3.00 (76.2) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.11 (2.8) 0.17 (4.3)

Note
2 1 Length from the operating shaft axis to the roller axis (or to the tip for non-roller operators).

V8-T2-84 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Operators
2.8
Roller on Reverse Side
2
C B
Approximate Dimensions in Inches (mm)

F Catalog Number
A
Lever Length 1
B
Roller Diameter
C
Roller Width D E F
2
E A
E50KL580 1.50 (38.1) 0.69 (17.5) 0.25 (6.4) 0.34 (8.6) 0.18 (4.6) 0.24 (6.1)
2
E50KL310 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.27 (6.9) 0.31 (7.9)
D E50KL579 1.50 (38.1) 0.75 (19.0) 0.32 (8.1) 0.34 (8.6) 0.27 (6.9) 0.31 (7.9) 2
0.44 0.67 E50KL536 1.50 (38.1) 1.50 (38.1) 0.28 (7.1) 0.34 (8.6) 0.23 (5.8) 0.31 (7.9)
(11) (17)
2
B
Dia
C Inboard
Roller
Offset Roller
2
Approximate Dimensions in mm [in]
D
38
A B C 2
24 Catalog Number Lever Length 1 Roller Diameter Roller Width D
2
[1.50]
26 [0.94] Inboard
[1.02] 20
[0.80] E50KL24 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 0.8 [0.03]
8.4
[0.33] 16 7.6 E50KL25 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 0.8 [0.03] 2
[0.64] [0.30] E50KL26
Outboard
38.1 [1.50] 17.5 [0.69] 6.4 [0.25] 1.0 [0.04]
2
E50KL27 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 0.8 [0.03] 2
E50KL28 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 0.8 [0.03]
E50KL29 38.1 [1.50] 17.5 [0.69] 6.4 [0.25] 1.0 [0.04] 2
2
E50KL30 38.1 [1.50] 19.0 [0.75] 25.4 [1.00] —

Bantam Lever 2
Approximate Dimensions
in mm [in] 2
4.1
22
[0.16] 4.6 2
[0.85] [0.18]

18 2
[0.69]
12
[0.48] 2
16 12.7
[0.62] [0.50] 2
B Dia. Precision Adjustment
2
Max Max C
60º 60º Approximate Dimensions in mm [in]
2
A B C
E
Catalog Number Lever Length 1 Roller Diameter Roller Width D E F
2
A E50KL340 17.5 [0.69] 19.0 [0.75] 8.1 [0.32] 12.2 [0.48] 6.1 [0.24] 7.1 [0.28]
20R
[0.80]
D
F
E50KL465
Roller length:
38.1 [1.50] 2
19.0 [0.75] 8.1 [0.32] 12.2 [0.48] 6.1 [0.24] 7.1 [0.28] 2
E50KL535 17.5 [0.69] 6.4 [0.25] 12.2 [0.48] 4.1 [0.16] 5.6 [0.22]
2
16 Precision
[0.63] Adjustment 12.7
Screw [0.50]
2
Notes
1 Length from the operating shaft axis to the roller axis (or to the tip for non-roller operators). 2
2 Maximum length dimension between operating shaft axis to the roller axis for comparison. Precision adjustable to lesser dimensions.

2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-85


2.8 Limit Switches
Operators

Adjustable Roller
2
B Dia. C
Approximate Dimensions in mm [in]

2 12.7
E
D 95R Catalog Number
A
Lever Length 1
B
Roller Diameter
C
Roller Width D E
[3.75]
[0.50]
2
108
[4.24] E50KL539 25.4 [1.0] to 17.5 [0.69] 6.4 [0.25] 5.8 [0.23] 7.6 [0.30]
95.2 [3.75] 2
25.4R E50KL201 19.0 [0.75] 8.1 [0.32] 7.4 [0.29] 8.4 [0.33]
2 [1.0]
E50KL201SPL 3 19.0 [0.75] 8.1 [0.32] 7.4 [0.29] 8.4 [0.33]
E50KL538 19.0 [0.75] 8.1 [0.32] 7.4 [0.29] 8.4 [0.33]
2 27
[1.08]
11
[0.42] 79
E50KL599 19.0 [0.75] 12.7 [0.50] 11.6 [0.46] 12.2 [0.48]

2
[3.12] E50KL537 19.0 [0.75] 25.4 [1.00] 22.9 [0.90] 24.1 [0.95]
E50KL598 12.7 [0.50] to 102.0 [4.00] 2.8 [0.11] 4.8 [0.19] 24.1 [0.95]

2
82.6 [3.25]
E50KL31 12.7 [0.50] to — — — —

2
95.2 [3.75]
E50KL443 41.3 [1.63] to 38.1 [1.50] 7.4 [0.29] 6.6 [0.26] 8.1 [0.32]
95.2 [3.75] 2
2
2 54 C Fork Lever—Both Rollers on One Side
[2.12]
Approximate Dimensions in mm [in]
2 38
[1.50]
27 A B C
B [1.06]
2 10 Catalog Number Lever Length 1 Roller Diameter Roller Width D E
Dia.
[0.38]
16 12 E50KL545 38.1 [1.50] 17.5 [0.69] 6.4 [0.25] 2.0 [0.08] 3.6 [0.14]
E 1.0
2 [0.62] [0.48]
D [0.04] E50KL204 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 4.1 [0.16] 5.1 [0.20]
E50KL544 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 4.1 [0.16] 5.1 [0.20]
2 E50KL543 38.1 [1.50] 19.0 [0.75] 25.4 [1.00] 21.3 [0.84] 22.4 [0.88]

2
54 Fork Lever—One Roller Outside, One Inside
2 [2.12]
38
C
Approximate Dimensions in mm [in]
[1.50)]
2 B
Dia.
27
[1.06] Catalog Number
A
Lever Length 1
B
Roller Diameter
C
Roller Width D E F G

2 16
[0.62]
12
[0.48] E
10
F [0.38]
E50KL542 38.1 [1.50] 17.5 [0.69] 6.4 [0.25] 2.0 [0.08] 3.6 [0.14] 16.3 [0.64] 17.8 [0.70]
D G E50KL203 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 4.1 [0.16] 5.1 [0.20] 18.5 [0.73] 19.6 [0.77]

2 E50KL541 38.1 [1.50] 19.0 [0.75] 8.1 [0.32] 4.1 [0.16] 5.1 [0.20] 18.5 [0.73] 19.6 [0.77]

2 Notes
1 Length from the operating shaft axis to the roller axis (or to the tip for non-roller operators).

2 2 By reassembling lever, minimum length can be reduced another 12.7 mm [0.5 in].
3 High-grade stainless steel.

2
2
2
2
2
2
2
2
2

V8-T2-86 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Operators
2.8
Approximate Dimensions in Inches or mm [in]
2
Rod Type Operators
2
Adjustable Rod
A B 2
A Catalog Number Rod Length 1 Rod Diameter
Max.
Ext. E50KL399 140.0 [5.50] 4.8 [0.19] 2
2
B Dia. E50KL202 3.2 [0.12]
E50KL581 222.0 [8.75] Rod size (square):
3.2 [0.12] x 3.2 [0.12]
E50KL220 229.0 [9.00] 4.8 [0.19]
2
16.26
[.64]
E50KL226 305.0 [12.00] 3.2 [0.12]
2
12.7
6.35
[.25]
[.50] 9.65
28.45 [.38] 2
[1.12]
Spring Rod—E50KL556 Spring Rod—E50KL421 Adjustable Wire
2

6.35 Dia.
2.29 Dia.
[0.9]
12.7
[.50]
2
228.6
2
[.25] Steel
247.90 Nylon [9.0] Spring Rod
[9.76]
307.85 6.6
[12.12]
Max.
[.26]
2
Ext. 3.05
[.12] Dia.
307.85
[12.12]
295.15
[11.62] 307.85 Nylon 2
[12.12] 1.52

16.26
[.06] Dia.
Steelcore
2
16.26 [.64]
6.35 12.7
[.64]
6.35
[.25]
12.7
16.26
[.64] 2
[.50] 9.65
[.25] [.50] 9.65 12.7
2
28.45 [.38] 6.35
28.45 [.38] [.50] 9.65
[1.12] [.25] [.38]
[1.12] 28.45
[1.12]
2
Adjustable Wide
Roller Lever Nylatron Loop—E50KL142 Eye Bolt 2
19.1 Dia.
[.75] 48.3
[1.90]
4.0 Dia.
[.158]
Max.
C
2
63.5
[2.50] 2
2
106.4 152.4 139.7
[6.00] [5.50] B A
[4.19] 31.8
Max. 16.3 [1.125]
[.64] Max.
2
12.7
[.50]
8.1 D
[.32]
2
4.2 0.44 0.67
9.7 +.05 Dia. 5.1 9.7
[.164] 6.4 22.9R 7.16 – .00 [.20] [11] [17]
12.7 [.38] [.38]
[.50] [.25] [.90] +.002 22.9

2
.282 – .000 [.90]
28.4 Catalog A B C
[1.12] Number Rod Length 2 Rod Diameter Rod Width D
E50KL33 38.1 [1.50] 4.8 [0.1875]
Loop ID: 9.5 [0.375]
13.1 [0.52] 8.6 [0.34] 2
2
Notes
1 Applies when lever is extended to the maximum dimension.
2 Length from the operating shaft axis to tip.
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-87


2.8 Limit Switches
Operators

Wobble Type Operators


2 Nylon Rod Stainless Steel Rod Coil Spring
2 1.60
6.35 [.063] Dia.
2
8.74 Dia.
[.250] Dia. [.344]
20.60
2 [.81] 346.45
[13.64]
146.30
[5.76]

2 124.45
[4.90]
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

V8-T2-88 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Non Plug-In Switches
2.9
Contents
Non Plug-In Switches
Description Page
2
Non Plug-In Switches 2
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V8-T2-90
Technical Data and Specifications . . . . . . . . . . V8-T2-91 2
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-91
2
2
2
2
2
2
2
Non Plug-In Switches 2
Product Description Features Standards and Certifications
DANGER
2
10316 Type L non plug-in ● Side and top rotary, side ● UL Listed
limit switches by Eaton’s and top push or wobble ● CSA Certified THIS SENSOR IS NOT A
SAFETY DEVICE AND IS NOT
2
electrical sector are sold operation
as complete assembled
devices only with a wide
● CW, CCW or CW and CCW INTENDED TO BE USED AS A
SAFETY DEVICE. This sensor 2
operating modes are field
is designed only to detect
array of operating head
configurations. All switches ●
convertible
Double break-make snap
and read certain data in an 2
are single-pole 1NO-1NC. electronic manner and
action contacts, same
polarity each pole
perform no use apart from 2
that, specifically no safety-
Captive saddle clamp
2

related use. This sensor
terminals accept up to product does not include
#12 wire
● Head can be mounted
self-checking redundant
circuitry, and the failure of 2
in any of four discrete this sensor product could
positions, intervals of 90° cause either an energized 2
or de-energized output
condition, which could result 2
in death, serious bodily
injury, or property damage.
2
2
2
2
2
2
2
2
For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
2
For the most current information
on this product, visit our Web site:
www.eaton.com
For Application Assistance in the U.S. and Canada
call 1-800-426-9184. 2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-89


2.9 Limit Switches
Non Plug-In Switches

Product Selection
2
2
Complete Assembled Switches Single-Pole 1NO-1NC
Operating Data—Nominal

2 Operating Characteristics
Travel to Operate
Contacts
Travel to Reset
Contacts Total Travel
Force to Operate
Contacts
Minimum
Return Force Catalog Number

2 Side Rotary Operated Side Rotary Operated 1

Standard 10° 4° 50° 3 in-lbs 4.5 in-oz 10316H187

2
2
2 Top Rotary Operated Top Rotary Operated 1
Clockwise 20° 12° 140° 1.1 in-lbs 3 in-oz 10316H700
2
2 Counterclockwise 20° 12° 140° 1.1 in-lbs 3 in-oz 10316H701

2
2 Side Push Operated Side Push Operated
Adjustable pushbutton 0.07 in (1.8 mm) 0.03 in (0.8 mm) 0.29 in (7.4 mm) 4 lbs 8 oz 10316H621
2
Vertical roller— 0.07 in (1.8 mm) 0.03 in (0.8 mm) 0.29 in (7.4 mm) 4 lbs 8 oz 10316H284
2 0.44 in (11.2 mm) dia.
Horizontal roller— 0.07 in (1.8 mm) 0.03 in (0.8 mm) 0.29 in (7.4 mm) 4 lbs 8 oz 10316H285
2 0.44 in (11.2 mm) dia.
Top Push Operated Top Push Operated
2 Pushbutton 0.04 in (1.0 mm) 0.02 in (0.5 mm) 0.28 in (7.1 mm) 4 lbs 8 oz 10316H281

2 Roller—0.44 in (11.2 mm) dia. 0.04 in (1.0 mm) 0.02 in (0.5 mm) 0.28 in (7.1 mm) 4 lbs 8 oz 10316H283

2 Roller—0.75 in (19.1 mm) dia. 0.04 in (1.0 mm) 0.02 in (0.5 mm) 0.28 in (7.1 mm) 4 lbs 8 oz 10316H577

2 Wobble Operated Wobble Operated 2


Spring 10° 6° 15° 1 in-lb 2.4 in-oz 10316H299
2 Nylon rod 10° 6° 15° 2 in-lbs 2.4 in-oz 10316H296

2 Wire 10° 6° 15° 2 in-lbs 2.4 in-oz 10316H484

Cat whisker 15° 5° 30° 0.63 in-lb 1.7 in-oz 10316H341


2
Notes
2 1 For operating levers, see Page V8-T2-80.
2 For wobble operators, see Page V8-T2-80.

2
2
2
2
2
2
2
2

V8-T2-90 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Non Plug-In Switches
2.9
Technical Data and Specifications
2
Non Plug-In Switches
Description Specification 2
Contact rating
Electrical life
NEMA A600, R300 double break-make snap action contacts
500,000 operations minimum
2
Mechanical life 5,000,000 operations minimum at full load 2
Conduit entrance 0.5 in (12.7 mm) NPT
Material of construction Zinc die cast 2
Enclosure rating NEMA 1, 4, 13
Ambient operating temperature –20° to 200°F (–29° to 93°C) 1
2
Approximate shipping weight 2 lbs
2
Electrical Data—Maximum Contact Ratings per Pole 2 2
Current, Amperes Volts, Amperes

AC Volts Make Break


Cont. Thermal
Ratings Make Break DC Volts
DC Current,
Ampere
2
NEMA A600, R300 Rating 2
120 60 6 10 7200 720 125 0.22
240 30 3 10 7200 720 250 0.11 2
480 15 1.5 10 7200 720 250 0.11
600 12 1.2 10 7200 720 250 0.11
2
2
Dimensions
Approximate Dimensions in Inches or Inches (mm) 2
Side Rotary Operated
Head with Switch
Side Pushbutton,
Adjustable Top Pushbutton Side Push, Vertical Roller
2
0.50 0.50
0.28
1.75 1.44
0.09
0.31 Sq. 3
0.31 Sq.
3 A 3
2
2
0.25 1.0 1.0
0.5 1.59 0.5
0.1 0.50
1.16

2
2.84 3.875 0.31 Max.
1.56 Adjustment
2.34 0.50 Dimension “A”
Pipe Tap

1.16 1.78
With 0.44 (11.2) dia. roller 1.78 (45.2)
2
1.55 With 0.75 (19.1) dia. roller 2.09 (53.1)
(2) 0.203 Dia. Holes for Front Mtg.
(2) 10-32 Tapped Holes 0.375 Deep
2
for Rear Mtg.

2
Side Push Maintained
Contact Top Push Roller Wobble Operators
Notes
2
2
0.31 0.16 3 1 Ranges below 32°F (0°C) are based on
2.97 Sq.
1.31 1.66 3 absence of freezing moisture or water.
0.25 B 2 Contacts must be same polarity when

1.0 A A
C 4
both circuits are used.
3 Dimension from centerline of head to
2
0.38 0.50
2
Dia.
0.5 mounting surface is 0.78 in (20 mm).
4 Center to mounting surface.

2
Dimension “A” A B C
With 0.44 (11.2) dia. roller 2.03 (51.6) Wobble Spring 2
With 0.75 (19.1) dia. roller 2.34 (59.4) 5.44 (138.2) 0.31 (7.9) 0.81 (20.6)
Wire Wobble Stick
2
12.5 (317.5) 0.08 (2.0) 0.81 (20.6)
2
Nylon Wobble Stick
4.5 (114.3) 0.25 (6.4) 0.81 (20.6) 2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-91


2.10 Limit Switches
Hazardous Location Limit Switches

Contents
2 Hazardous Location Limit Switches
Description Page
2 Hazardous Location Limit Switches
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V8-T2-93
2 Technical Data and Specifications . . . . . . . . . . V8-T2-94
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-91
2
2
2
2
2
2
2
2 Hazardous Location Limit Switches
2 Product Description Features Standards and Certifications
DANGER
Type LX, CX and CBX limit ● Sealed and unsealed ● cUL
2 switches by Eaton’s electrical versions available THIS SENSOR IS NOT A
SAFETY DEVICE AND IS NOT
sector are designed for ● One-way gasket on sealed
2 extreme environmental
service in NEMA 7–9
version keeps liquids out, INTENDED TO BE USED AS A
SAFETY DEVICE. This sensor
yet allows a harmless
is designed only to detect
2 locations where the danger
of an internal or external
release of gases in the
event of an internal and read certain data in an
explosion of flammable explosion electronic manner and
2 gases, vapors, metal alloy ● Silicon bronze housing
NEMA Ratings Comparison
Switch Type
perform no use apart from
or grain dust exists. Type CB that, specifically no safety-
provides excellent
2 provides excellent corrosion
resistant properties in
corrosion resistant
LX CX CBX CB 1 related use. This sensor
product does not include
properties in extreme NEMA 1, 4, 13
2 NEMA 4X applications.
Markets served include
NEMA 4X applications — ✔ ✔ ✔
self-checking redundant
circuitry, and the failure of
mining, grain storage, forest
● Temperature buildup on NEMA 4X this sensor product could
2 products, petrochemical, limit switch surface is
— — ✔ ✔ cause either an energized
pharmaceutical and waste dissipated by housing or de-energized output
2 and sewage management. design and materials used NEMA 7 Division I, Class I, BCD
✔ ✔ ✔
condition, which could result
● Utilizes the operating — in death, serious bodily
2 heads and internal
switch mechanisms of the
NEMA 9 Division I, Class II, EFG injury, or property damage.
✔ ✔ ✔ —
10316 L non plug-in line
2 Note
1 Not rated for explosive locations.

2
2
2
2
2
2
2 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
For the most current information
2 on this product, visit our Web site:
www.eaton.com
For Application Assistance in the U.S. and Canada
call 1-800-426-9184.

V8-T2-92 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Hazardous Location Limit Switches
2.10
Product Selection
2
Complete Assembled Switches with Spring Return Heads 1

Operating Data—Nominal
2
Travel to Operate Travel to Reset
Force to
Operate Minimum Body 2
Head Type Contacts Contacts Total Travel Contacts Return Force Type Contacts Catalog Number
Side Rotary Standard, 10° Pre-Travel 3 2
Operated 2
2
10° 4° 50° 3.0 in-lbs 4.5 in-oz Type LX 1NO-1NC 4 10316H1002
2NO 10316H1039
1NO and 1NC 4 10316H1049
2
2NC 10316H1059
Type CX 1NO-1NC 4 10316H2200 2
1NO and 1NC 4 10316H2176
2NC 10316H2178 2
2
Type CB 1NO-1NC 4 10316H2149
2NC 10316H2140
Type CBX 1NO-1NC 4 10316H2168 2
2NC 10316H2159
Narrow Differential 5° Pre-Travel 3 2
5° 2° 50° 6.0 in-lbs 4.5 in-oz Type LX 1NO-1NC 4 10316H1146
Type CX 1NO-1NC 4 10316H2197
2
Neutral Position, 18° Pre-Travel 5
2
18° 6° 50° 1.8 in-lbs 2.5 in-oz Type LX 2NO 10316H1071
2NC 10316H1072 2
Type CX 2NO 10316H2179
Type CBX 2NC 10316H2160 2
2
Side Push Operated Pushbutton
0.07 in (1.8 mm) 0.03 in (0.76 mm) 0.29 in (7.4 mm) 4 lbs 8 oz Type LX 1NO and 1NC 4 10316H1213
Adjustable Pushbutton
2
0.07 in (1.8 mm) 0.03 in (0.76 mm) 0.29 in (7.4 mm) 4 lbs 8 oz Type LX 1NO-1NC 4 10316H1192
Vertical Roller, 0.44 in (11.2 mm) Diameter 2
0.07 in (1.8 mm) 0.03 in (0.76 mm) 0.29 in (7.4 mm) 4 lbs 8 oz Type LX 1NO-1NC 4 10316H1007
Vertical Roller, 0.75 in (19.1 mm) Diameter 2
0.07 in (1.8 mm) 0.03 in (0.76 mm) 0.29 in (7.4 mm) 4 lbs 8 oz Type LX 1NO-1NC 4 10316H1194
2
Notes 2
1 Contact Eaton’s Sensor Applications Engineering at 1-800-426-9184 for replacement contact blocks.
2 For operating levers, see Page V8-T2-80. Only levers with Nylatron rods or rollers should be used with explosion-proof limit switches. 2
3 Field convertible to clockwise only or counterclockwise only operation.
4 1NO-1NC contacts must be same polarity when both circuits are used—1NO and 1NC contacts have isolated poles and may be used on opposite polarity.
5 Neutral position switches operate one circuit in each direction.
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-93


2.10 Limit Switches
Hazardous Location Limit Switches

Complete Assembled Switches with Spring Return Heads, continued 1


2 Operating Data—Nominal

2 Travel to Operate Travel to Reset


Force to
Operate Minimum Body
Head Type Contacts Contacts Total Travel Contacts Return Force Type Contacts Catalog Number
2 Top Push Operated Pushbutton

2
0.04 in (1 mm) 0.02 in (0.5 mm) 0.28 in (7.1 mm) 4 lbs 8 oz Type LX 1NO-1NC 2 10316H1004
Type CX 1NO and 1NC 2 10316H2188

2 Adjustable Pushbutton
0.04 in (1 mm) 0.02 in (0.5 mm) 0.28 in (7.1 mm) 4 lbs 8 oz Type LX 1NO-1NC 2 10316H1191
2 1NO and 1NC 2 10316H1212
Roller, 0.44 in (11.2 mm) Diameter
2 0.04 in (1 mm) 0.02 in (0.5 mm) 0.28 in (7.1 mm) 4 lbs 8 oz Type LX 1NO-1NC 2 10316H1006

2 Roller, 0.75 in (19.1 mm) Diameter


Type CBX 1NO-1NC 2 10316H2170

2 0.04 in (1 mm) 0.02 in (0.5 mm) 0.28 in (7.1 mm) 4 lbs 8 oz Type LX 1NO-1NC 2 10316H1193
Wobble Operated Spring
2 10° 3 6° 15° 1 in-lb 2.4 in-oz Type LX 1NO-1NC 2 10316H1237

2 Nylon Rod

2 10° 3 6° 15° 2 in-lbs 5.6 in-oz Type LX 1NO-1NC 2 10316H1009

2
2 Technical Data and Specifications
2 Hazardous Location Limit Switches

2 Description Specification
Material of construction
2 LX, CX Cast aluminum die cast
CB, CBX Silicon bronze
2 Conduit entrance
LX 1/2 in pipe tap
2 CB, CBX, CX 3/4 in pipe tap

2
Mounting Surface mount
Enclosure rating

2 LX, CX, CBX


CB, CBX
NEMA 7 Div. 1, Class I BCD; NEMA 9 Div. 1, Class II, EFG 4
NEMA 1, 4, 4X, 13 4

2 CX NEMA 1, 4, 13 4
Ambient operating temperature –20° to 200°F (–29° to 93°C) 5
2 Approximate shipping weight
LX 2 lbs
2 CX 2.5 lbs

2
CB, CBX 6 lbs

Notes
2 1 Contact Eaton’s Sensor Applications Engineering at 1-800-426-9184 for replacement contact blocks.
2 1NO-1NC contacts must be same polarity when both circuits are used—1NO and 1NC contacts have isolated poles and may be used on opposite polarity.

2
3 Travel with force applied at one-in (25.4 mm) radius. Applied at end of operator, travel is approximately 14.
4 A conduit seal-off kit is required for these switches
5 Ranges below 32°F (0°C) are based on absence of freezing moisture or water.

2
2
2

V8-T2-94 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Hazardous Location Limit Switches
2.10
Electrical Data—Maximum Contact Ratings, per Pole
Current, Amperes Volt Amperes DC Current,
2
2
AC Volts Make Break Cont. 1 Make Break DC Volts Ampere
1NO-1NC Switches
NEMA A600, R300 rating 2
120 60 6 10 7200 720 125 0.2
240 30 3 10 7200 720 250 0.1 2
2
480 15 1.5 10 7200 720 250 0.1
600 12 1.2 10 7200 720 250 0.1
All Other Switches, B600
2
120 30 3 5 3600 360 120 0.1
240 15 1.5 5 3600 360 240 0.05 2
480 7.5 0.75 5 3600 360 240 0.05
600 6 0.60 5 3600 360 240 0.05 2
2
Dimensions
Approximate Dimensions in Inches or Inches (mm) 2
Type LX Switch with
Side Rotary Head Side Pushbutton Head Top Pushbutton Head
Side Push, Vertical
Roller Head 2
0.50
2.81
1/4-20
Pipe Tap
0.28 Deep
1.44
0.31 Sq. 5 0.31 Sq.
5 A 5
2
Both

2
0.69
1.0 1.0
0.31 Sides 0.5
1/4-20
0.5 1.59
0.27 Dia.
5.22 Pipe 0.875 2 Holes
0.50
Tap

2
5/16-18
4 3.38 0.31 Pipe Tap
Deep
Both 0.56 Dimension “A”
Sides Deep
Both

2
Sides
0.50
With 0.44 (11.2) dia. roller 1.78 (45.2)
0.27 Dia. 1.44 1.19 0.25
2 Holes Pipe
2.25 Tap 2.25 With 0.75 (19.1) dia. roller 2.09 (53.1)

2
Type CX, CB and CBX
2
Switches with Adjustable Top
Side Rotary Head Pushbutton Head Wobble Operators 2
.277
.50
3.08 0.31 Sq.
0.10 0.31 Max.
Notes
1 1NO-1NC contacts must be same 2
.685 Adjustment B polarity when both circuits are used—
0.257 Dia. .325
2
A
3
1NO and 1NC contacts have isolated
poles and may be used on opposite
2
4 Mtg. Holes C
3.50 1.69
2
polarities.
5.35 3/4-14 Taper 4.165 0.50 2 Dimension from centerline of head to
Pipe Tap .945
mounting surface is 0.78 in (20 mm).

2.36 2.54
Type CX
Type CBX
0.25
3 Center to mounting surface.
2
3.00
2.60 Type CB A B C
Wobble Spring 2
Adjustable Side
Pushbutton Head Top Push Roller Head
5.44 (138.2)
Nylon Red
0.31 (7.9) 0.94 (23.9)
2
1.44
0.09
0.31 Sq.
2 0.16 5 4.5 (114.3) 0.25 (6.4) 0.94 (23.9) 2
2
1.0
0.5
0.1 A
0.31 Max.
2
1.56 0.50
Adjustment

Dimension “A”
2
With 0.44 (11.2) dia. roller 2.03 (51.6) 2
With 0.75 (19.1) dia. roller 2.34 (59.4)
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-95


2.11 Limit Switches
Special Purpose Limit Switches

Contents
2 Special Purpose Limit Switches
Description Page
2 Special Purpose Limit Switches
Product Selection
2 Roller Lever Switches . . . . . . . . . . . . . . . . . V8-T2-97
Rotating Shaft Switches . . . . . . . . . . . . . . . V8-T2-97
2 Pneumatic Time Delay Switches . . . . . . . . V8-T2-98
Precision Switches . . . . . . . . . . . . . . . . . . . V8-T2-98
2 Technical Data and Specifications . . . . . . . . . . V8-T2-99

2
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T2-101

2
2
2
2
2 Special Purpose Limit Switches
2 Product Description Features Standards and Certifications
DANGER
Special Purpose (Type F), ● UL Listed Type F
2 Rotating Shaft (Type J), ● CSA Certified ● UL Listed THIS SENSOR IS NOT A
SAFETY DEVICE AND IS NOT
Pneumatic Time Delay (Type (PS and J only)
2 LP) and Precision and Cabinet
Door Interlock (Type PS) Limit
Type J INTENDED TO BE USED AS A
SAFETY DEVICE. This sensor
● UL Listed is designed only to detect
2 Switches from Eaton’s
electrical sector serve a
● CSA Certified and read certain data in an
variety of special purpose electronic manner and
2 industrial applications for Type LP perform no use apart from
MRO and User Replacement ● UL Listed that, specifically no safety-
2 requirements.
Type PS
related use. This sensor
product does not include
2 UL Recognized self-checking redundant

● CSA Certified circuitry, and the failure of


this sensor product could
2 cause either an energized
or de-energized output
2 condition, which could result
in death, serious bodily
2 injury, or property damage.

2
2
2
2
2
2
2
2 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
For the most current information
2 on this product, visit our Web site:
www.eaton.com
For Application Assistance in the U.S. and Canada
call 1-800-426-9184.

V8-T2-96 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Special Purpose Limit Switches
2.11
Product Selection
2
Roller Lever Switches
2
Roller Lever Type F Switches 1
Travel to Operate Travel to Reset 2
Operator Circuit Contacts Contacts Total Travel Over-Travel Catalog Number
Roller lever (CW and CCW operation, 1NO-1NC 40° 35° 65° 25° 10316H18 2
spring return)
2
2NO-2NC 17° 6° 60° 43° 10316H320
2
2
2

Rotating Shaft Switches


2
Type J 2
Rotating Shaft Limit Switches contacts will trip when
allow the shaft to be rotated a reaching a preset limit in the 2
preset number of revolutions opposite direction. These
(adjustable from 1/2 to 100
with an accuracy of 1/20 of a
switches are typically used in
crane and hoist applications
2
turn) before the contacts will
switch. A second set of
to provide end of travel stops
for the hook assembly. 2

Rotating Shaft Type J Switches 2


Shaft to Max. Turns to Min. Turns to Over-Travel Before
Reversal After
Tripping to Enclosure 2
Cam Ratio Trip Contacts Trip Contacts Resetting Contacts Reset Contacts Circuit 2 Rating Catalog Number
103:1 100 input 1/2 input 103 input 1/8 input 2NC NEMA 1 10316H50 2
shaft turns shaft turns shaft turns max. shaft turns min.
2
3 3

2
2NO-2NC NEMA 4 10316H54

Notes
2
2
1 Replacement operator head is available with part number 86-862-22.

Replacement roller lever is available with part number 24-1712.


Replacement key pin and washer for roller is available with part number 16-906.
2 For replacement NO contacts, order 17-1403; NC contacts, order 17-702.
3 10316H54 has factory set circuits, but is easily convertible to any of three circuits (2NO-2NC, 4NO or 4NC).
2
2
Full instructions enclosed with every switch.

2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-97


2.11 Limit Switches
Special Purpose Limit Switches

Pneumatic Time Delay Switches


2
Type LP Switches
2 Pneumatic Time Delay
Timed Direction of
Operator Total Travel Pre-Travel Circuit Contacts Rotation 2 Catalog Number
2 Side rotary 50° 10° 1NO-1NC ON delay CW 10316H1580
(Spring return to center) 1
2 CW and CCW 10316H1600

2 OFF delay CW 10316H1610

2 CW and CCW 10316H1630

2
2 Precision Switches
2 Type PS Switches
Cabinet Door Interlock
2 Circuits—
SPDT 1NO-1NC
Circuits—
DPDT 2NO-2NC Operator Only
Operator Catalog Number Catalog Number Catalog Number
2 Precision Switch Devices

2 Precision switch only 10316H89 10316H2000 —


Pushbutton with oiltight plunger — 10316H2006 —

2 Roller with oiltight plunger perpendicular to mounting holes — 10316H2012 —


Roller with oiltight plunger in line with mounting holes 10316H110 — —
2 6 in lever with top and right-hand mounting bracket 10316H113 — 10316H143

2
6 in lever with top and left-hand mounting bracket — — 10316H144
Roller lever with top and right-hand mounting bracket 10316H119 — 10316H145

2 Roller lever with top and left-hand mounting bracket 10316H122 — 10316H146
One way roller lever with top and right-hand mounting bracket — — 10316H147
2 One way roller lever with top and left-hand mounting bracket — — 10316H148
Cabinet Door Interlocks
2 Precision switch only 10316H828 10316H829A —

2 Cabinet door interlock operator with one precision switch and


with red (defeated 3) indicator
10316H1028 10316H2042 10316H150

2
Cabinet door interlock operator with two each of listed precision 10316H1029 — —
switches and with red (defeated 3) indicator

2 Notes
1 Requires an operating lever, see Page V8-T2-80.
2 Field convertible.

2 3 The plunger exposes a red band when pulled out to indicate that interlock is defeated.

2
2
2
2
2
2
2
2

V8-T2-98 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Special Purpose Limit Switches
2.11
Technical Data and Specifications
2
Special Purpose Limit Switches
Description Specification 2
Roller Lever Switches—Type F
Enclosure rating NEMA 4
2
Operating temperature 0° to 180°F (–18° to 82°C) 2
Conduit entrance 0.5 in NPT
Shipping weight 4.0 lbs 2
Rotating Shaft Switches—Type J
Shipping weight
2
NEMA 1 models
NEMA 4 models
5.5 lbs
13 lbs
2
Pneumatic Time Delay Switches—Type LP
2
Timing range 0.05 to 60 seconds
ON delay function Timing begins when lever is actuated and held 2
OFF delay function Timing begins when lever is released
Repeat accuracy 1 With 15 second or higher interval between timing periods: ±10% of setting maximum 2
With less than 15 second interval between timing periods: ±25% of setting maximum
Operating frequency 250 operations per minute maximum 2
Enclosure rating
Ambient operating temperature
NEMA 4, 13
32° to 150°F (0° to 65°C)
2
Conduit entrance 0.5 in NPT
2
Shipping weight 2 lbs

Note 2
1 To maintain operating accuracy during the timing cycle, the switch lever must be faster than the timed setting.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-99


2.11 Limit Switches
Special Purpose Limit Switches

Type F—Maximum Ampere Ratings


2 AC Volts DC Volts

2 Circuit
1NO-1NC
State
Make
120
60
240
30
480
20
600
15
120

240

600

2 Break 6 3 1.5 1.2 2.2 1.1 0.40


2NO-2NC Make 40 20 10 8 — — —
2 Break 15 10 6 5 0.5 0.2 0.02

2
Type J—Maximum Ampere Ratings
2 AC Volts DC Volts

2
State 120 240 480 600 120 240 600
Make 60 30 15 12 2.2 1.1 —

2 Break 6 3 1.5 1.2 2.2 1.1 —


Continuous 1 10 10 10 10 10 10 —
2
2 Type LP— Electrical Data, Maximum Contact Ratings/Pole
Current, Amperes Volt Amperes DC Current
2 AC Volts Make Break Cont. 1 Make Break DC Volts Amperes
All Switches 1NO-1NC
2 NEMA A600, R300 Rating

2 120 60 6 10 7200 720 120 0.2


240 30 3 10 7200 720 240 0.1

2 480 15 1.5 10 7200 720 240 0.1


600 12 1.2 10 7200 720 240 0.1
2
2 Type PS—Maximum Ampere Ratings
DC Volts
2 AC Volts Double Throw
Type State 120 240 480 600 120 240 600
2 Heavy-Duty 1/2 hp, 250 Vac Maximum

2 Single-pole Make 40 20 10 8 2.0 0.5 0.1


Break 15 10 6 5 0.5 0.2 0.02

2 Double-pole Make 30 15 8 6 0.5 0.2 0.2


Break 3 1.5 1 0.8 0.2 0.1 —
2 Note

2
1 Thermal rating. Valid only if switch does not have to make or break.

2
2
2
2
2
2
2
2

V8-T2-100 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com


Limit Switches
Special Purpose Limit Switches
2.11
Dimensions
Approximate Dimensions in Inches (mm) 2
Roller Lever Switches 2
Type F 2
3.00 (76.2)
1- & 2-Pole 2
3.31 (84.1) 3-Pole

6.88 (174.8) 1- & 2-Pole 2.69 (68.3) 2


7.69 (195.3) 3-Pole 1- & 2-Pole

1.31 (33.3)
3.00 (76.2)
3-Pole
2
1- & 2-Pole
1.13 (28.7)
3.66 (93.0)
1- & 2-Pole 2
3-Pole 3.75 (95.3)
3-Pole
2
2
Approximate Dimensions in Inches only
2
Rotating Shaft Switches 2
Type J—NEMA 1 Models Type J—NEMA 4 Models
2
2
2
2
2
2
2
Pneumatic Time Delay Switches
2
Type LP
2
2
2
2
2
2
2
2
2
2
2

Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com V8-T2-101


2.11 Limit Switches
Special Purpose Limit Switches

Approximate Dimensions in Inches [mm]


2
Precision Switches
2 Type PS
2 0.156 [4] Dia.
2 Mtg.
0.81 [21] 0.157 [4] 15/32-32 1.05 [26.6]
Thread 0.97 [25]
0.31 3.84 [98]
Holes 0.137 [3.5] [8] 2.69 [68]
2
Stroke 0.78
2.125 [54] 0.199 [5] 2.69
2.47 [63] [20] [68]
0.25 [6.4]
1.05 1.2 2.31

2 [26.5] [26] [59]


0.345 [8.7] 0.81
1.89 2.47 [63] [21] 0.16 [4.3] 0.25
[48] Dia. 4 Holes 0.56 [14] [6.4]
2 Contact Block Mechanism Pushbutton Type
#10-32 Tap
2 Holes
0.88 [22]
1.03
[26]
2 Cabinet Door Type
Two Contact Blocks
6.0 0.16 [4.3]
1.22 [31]
2
1.54 [11.1] [152] Dia.
Dia. 4 Holes
0.78 [13.8]
[20] 1.45
[11.5] 0.69

2 1.20 [17.5]
[30.5] 2.59 [66]
0.5 [13] 2.31 [59]
2.47 [63] 0.81 [21] 2.81 [71] 0.97 [24.6] 2.69
2 Push Roller Type 6 in Lever Type 2.31[68]
[59]

2
0.56 0.25
[14] 0.16 [4.3] [6.4]
0.38 [9.5] 0.38 [9.5] Dia. 2 Holes
1.84 0.16 [4.3] 1.84 0.16 [4.3] #10-32 Tap

2 [47] Dia. [47] Dia. 0.88 2 Holes


1.38 [35] 4 Holes 1.0 [25] 4 Holes [22] 1.03 [26]
0.69 0.69
2 [17.5] Cabinet Door Type
[17.5] One Contact Block
0.5 [13] 2.31 [59] 2.31 [59]
2.81 [71] 0.5 [13]
0.97 [24.6] 0.97 [24.6]
2
2.81 [71]
One Way Roller Type Roller Lever Type

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

V8-T2-102 Volume 8—Sensing Solutions CA08100010E—August 2012 www.eaton.com

Das könnte Ihnen auch gefallen