Planning Manual Beauty Angel CVT 42

Beauty Angel CVT 42 offers an innovative light treatment for


photo-bio stimulation of the skin.
The application of red light promotes the formation of collagen
and elastin. The short-term effect shows itself as a firmer and
closer skin feeling and a more vital facial colouration. The skin
complexion improves over the middle and long term and natu-
ral signs of aging are alleviated.
Three treatment programmes are available which are specially

Beauty Angel CVT 42


designed for the needs of young, adult and mature skin.
The 3D sound system with subwoofer, MP3 dock and SD card
slot promises a first-class sound experience.
The unit is also equipped with Vibra Shape. Four vibration pro-
grammes with different vibration frequencies provide, for
example, improved fat oxidation or muscle development.

Contents

Device description . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Equipment cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Body cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Area cooling – Auxiliary exhaust air box . . . . . . . . . 4
Vibration plate (Vibra Shape). . . . . . . . . . . . . . . . . . . 5
Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . 5
Sound system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Air conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
IR-interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Accent lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Beauty Angel CVT 42 – 1


Beauty Angel CVT 42 Planning Manual

Device description
1. Adjustable feet
2. Base plate
3. Foot mat (silicone) and vibration plate
(Vibra Shape)
4. Beauty Light lamps
Beauty Angel CVT 42

5. Operating panel, headphone connection


6. Handles
7. Loudspeaker (optional)
8. Fans (body cooling)
9. Interior lighting (LED)
10. Door handle
11. Accent lighting
12. Exhaust air (body cooling)
13. Exhaust air (equipment cooling)
14. Cable duct and ambient light 
(accent lighting)

Technical data

Electrical data Noise emission


Nominal power consumption: 8700 W Acoustic pressure level: approx. 71.6 db (A)
Nominal voltage: 400 – 415 V 3N~ Inlet and exhaust air
Nominal frequency: 50 Hz Temperature difference, supply/
12 °C
Rated fusing: 3 x 20 A (time delay) exhaust air:

Mains supply line (for example): Max. air requirement: 2400 m3/h
H05VV-F 5G 4 mm2
or Opt. ambient temperature: 25-30 °C

Nominal voltage: 230 – 240 V ~3 Max. ambient temperature: 15-40 °C

Nominal frequency: 50 Hz Max. inlet air temperature: 40 °C

Rated fusing: 3 x 25 A (time delay) Exhaust cross section w/o exhaust



system:
Mains supply line (for example): H05VV-F 5G 4 mm 2
Cabin inlet air cross section: 4600 cm2
Weight: 315 kg
Exhaust cross section with exhaust
Performance: –
system:
Door: Warm air return: not possible
Beauty Light lamps 14 x 180 W
Side part:
Beauty Light lamps 28 x 180 W

2 – Beauty Angel CVT 42


Planning Manual Beauty Angel CVT 42

Dimensions

B 1392 mm
B1 864 mm
B2 866 mm
B3 166 mm

Beauty Angel CVT 42


B4 1367 mm
T 1279 mm
T1 1380 mm
T2 1837 mm
T3 865 mm
H 2341 mm
H1 69 mm
H2 2600 mm
H3 2020 mm
BK 1935 mm
BK1 500 mm
BK2 500 mm
TK 2400 mm
TK1 880 mm
TK2 300 mm

Beauty Angel CVT 42 – 3


Beauty Angel CVT 42 Planning Manual

Equipment cooling
One fan (2) is installed in the walls and the door (respectively) to cool the device.
The 3 fans draw in air above (1) the panel and at the bottom of the door and the side
walls (3). The air which is drawn in is fed past the heated Beauty Light lamps and routed
to the outside.
Beauty Angel CVT 42

Body cooling
Body cooling is provided by 3 fans (4). The cabin air is drawn in below and through the
slits between the side walls and the door and fed past the person standing underneath.
The fans can be continuously adjusted.

Area cooling – Auxiliary exhaust air box

If required the auxiliary exhaust box (5) can route the warm expelled exhaust air of the
equipment cooling to a ventilation system or outside the cabin area.

4 – Beauty Angel CVT 42


Planning Manual Beauty Angel CVT 42

Vibration plate (Vibra Shape)


A vibration plate is integrated into the standing surface. Four programmes utilizing different vibration frequencies can be set up. The
vibration programmes all run for 10 minutes but can also be customized on an individual basis depending on the intensity of the pro-
gramme or switched off completely.
As a rule users can combine the light application and the vibration programme with each other as desired or utilize them completely
separately as individual applications.

Beauty Angel CVT 42


Electrical connections

Mains supply line 4.4 m with plug


Electr. control line none
Line for external music and channel selection none

Sound system

Description: Article No. Notes


Stereo sound 100001819 optional
3D sound unit (MP3-Dock-in) 100001841 optional

Controls

Control Article No. Notes


MCS III plus hand-held remote control 500000456 with chip card terminal
MCS IV plus 34010400 with electronic coin tester
MCS VI 34009700 with electronic coin tester + chip card terminal

Air conditioner
No air conditioner can be supplied with this device model.

IR-interface
There is no ir interface supplied with this device model. Access to the device data with hand-held unit (Palm) is not possible.