feature vertical turbine pumps

Resonant vibrations in
vertical pumps
Variable speed driven motors for vertical pumps are known to exhibit operating
zones that are subject to excessive vibration. In part one of this paper, Bill Beekman
of Weir Floway Pumps discusses the influence of excessive resonance and how it
can be managed. In part two, he discusses the caution required when starting and
stopping VFDs or Soft Start/Stop Driven vertical turbine pumps.

V
ertical pump and motor The most appropriate procedure in operational range. As this could
structures are particularly this situation is to select a fabricated become costly, it is recommended that
susceptible to a resonance discharge head that can be easily the specifying engineer consults with
condition created by the coincidence changed dimensionally rather than a the pump manufacturer prior to
of the operating rpm with the Natural cast discharge head that is usually specifying motor synchronous speeds
Reed Frequency (NRF) of the pump difficult to structurally modify. and speed ranges when the vertical
structure. Excessive resonant induced Reliable motor Reed Critical pump is driven by a variable speed
vibration occurs in a vertical pump Frequency (RCF) data is required driver.
when the natural frequency of the when computing the pump and
pump discharge head and vertical motor’s combined structural RCF.
driver are the same as the speed of the This is normally available from most Mounting
pump and drive. manufacturers of vertical motors. It is foundations
worth noting that the motor’s RCF
For custom engineered vertical pumps will vary between different motor The foundations on which the
driven by a variable speed or constant manufacturers and their style of motor vertical pump is mounted do require
speed driver, it is recommended that construction. Often the pump consideration. As a rule, it is
the pump discharge head and driver manufacturer will select a specific advisable to provide a foundation that
structure are evaluated for resonance motor manufacturer that can provide represents less than 5% of the total
conditions across the intended the optimum RCF required for the deflection of the structural elements
operating speed range. However, a NRF of the head and motor. of the pump/drive. Typically a
pre-engineered standard constant reinforced concrete foundation will
speed vertical pump generally does Events can dictate that the pump’s comply with these criteria.
not require individual job evaluation. maximum synchronous speed must be
increased or reduced; i.e. from 6 pole If the natural frequency is close to
to 4 pole or 6 pole to 8 pole, in order the maximum rpm operating range
Industry design to achieve the desired non-resonance (Figure 1), the unit can be stiffened
practice
Most vertical pump manufacturers
Maximum operating rpm
have in-house technology to de-
termine the NRF of their pumps.
Within the vertical pump industry it
is normal practice to design the drive Natural frequency
support (discharge head) so that the
Head

NRF of the head and motor have a


separation margin of either 20%
System curve
above the maximum operating rpm or
20% below the minimum operating Minimum operating rpm Vibration band
rpm.

When the desired rpm operating


range is within the structure’s NRF, it Capacity

is necessary to alter the pump’s


discharge head and motor stiffness. Figure 1. Natural frequency is close to the maximum range of operating rpm.

18 0262 1762/04 © 2004 Elsevier Ltd. All rights reserved WORLD PUMPS November 2004
feature vertical turbine pumps

to make it more robust. However,


there is a limit to the pump
manufacturer’s ability to add rigidity
to the unit’s structure and obtaining a Maximum operating rpm

vertical motor that has a high level


Natural frequency
of rigidity may not be feasible.
Therefore, by providing a more robust

Head
motor support in the form of a
fabricated discharge head, it may be System curve
possible to raise the pump’s structural
Minimum operating rpm
natural frequency above maximum Vibration band
operating speed.

If the natural frequency is close to the


minimum rpm operating range Capacity
(Figure 2), the unit can be made more
flexible. This has the effect of Figure 2. Natural frequency is close to the minimum range of operating rpm.
lowering the natural frequency below
the operating range. During start-up useful range of operation. Therefore, turbine pumps, consideration has to
and shutdown, the unit will pass it is usually desirable to change the be given to those features that can be
through its natural frequency and rigidity of the pump/motor structure influenced when Soft Start/Soft Stop
vibration may occur. However, this in order to move the resonance band (SS/SS) or Variable Frequency Drives
vibration should not inflict any away from the desired operating zone (VFD) are employed. Mix Flow and
damage as it occurs for only a very (Figure 3). Axial flow pumps are particularly
short time. sensitive to starting and stopping
where either VFDs or SS/SS driven
Excessive pump/motor vibration does Part two: Stopping motors are employed. This is because
occur when the variable speed driven and starting VFDs the horsepower curve rises towards
pump and motor are run in the non- or vertical turbine shut-off head.
continuous operation zone. Locking pumps
out the speed zone of operation on a The water works industry provides
motor controlled by a variable When it comes to the start and stop good examples of the issues that need
frequency drive may limit the pump’s phases of operating vertical drive to be addressed.

Figure 3. Typical vibration


signature of discharge
X head/motor structure.

Y Y
Y –Y
X–X
X

Motor
Displacement

Discharge
head

Non continuous
Foundation
operation zone

900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900
Frequency (CPM)

20 www.worldpumps.com WORLD PUMPS November 2004


feature vertical turbine pumps

Downstream valves adjustment of all components prior to


first start-up. Serious pump and motor
Having a detailed knowledge of the failure have been recorded simply
types of valve technology lying because synchronizing electrical
downstream of the pump is important controls with valves was not
as all valves must be synchronised with accomplished.
the VFD & SS/SS motor controllers
when starting and stopping a pump.

Check valves
In a typical scenario, there may be
combinations of the following valves When a check valve is used in the
beyond the pump’s discharge point: piping system the opportunity for back
flow from the piping system
• Check Valve interrupting pump start-up or shut-
• Flow Control Valve (FCV), Motor- down is removed. When shutting
ized Butterfly, Gate, Ball, etc. all down longer, deeper setting, pumps
with time adjustable opening and the water column in the pump rushes
closure and no check valve. down through the pumping bowl
assembly to the standing water level
Other types of valves may be used to and the reverse flow creating backspin
control pump and system operations, torque on the pumpshaft. If the motor
but for the purpose of this article these is programmed to decelerate it is still
types of valves are the focus of trying to drive the pump forward.
attention. When this adverse condition occurs,
the pump’s drive shaft and motor are
subjected to a significant torque
overload. To prevent this occurrence
Drives and motors
at shut down, a device that electrically
Awareness of the ability of VFDs and disconnects the motor is required. The
SS/SS to control pump start-up and types of valves located downstream of
shut-down time is very important. the pump have very little effect on the
VFDs are used to vary the motor speed severity of this occurrence.
in order to enable the pump to provide
variable rates of flow to meet the With the presence of only a check
system requirements. They have time valve in the piping system down-
adjustable ramp-up and ramp-down stream of the pump, there is little
features for controlling motor chance of motor overload occurring
acceleration and deceleration times. during starting ramp-up of Turbine,
The controller can also be pro- Mix Flow and Axial Flow pumps.
grammed to electrically disconnect the However, it advisable to have an
motor on signal to shut down. electrical disconnect to the motor on
pump shut down.
SS/SS controllers are generally
selected as motor drives for the purpose
of reducing electrical in rush power
Start up without check
during start-up and cushioning valves
valves
from system hydraulic transients
(water hammer) during shut down. Where flow control valves do not
They feature programmable ramp-up incorporate a check valve, pump start-
and ramp-down times and may also be up time must be carefully synchro-
programmed to electrically disconnect nized with the valve opening to
the motor on signal to shut down. prevent system backflow into the
pump prior to the pump attaining full
speed. Thus a very short ramp-up
time, ideally less than five seconds, is
Synchronizing start-up
desired. It is essential that the flow
and shut-down times
control valve should not begin to
It is essential to recognize that there is open prior to the pump attaining full
a need to ensure the correct timing speed as the pumpshaft and motor will

WORLD PUMPS November 2004 www.worldpumps.com 21


feature vertical turbine pumps

Figure 4. Floway 2500 depth below the surface, deeper


HP - 900 RPM High
setting pumps are pre-lubricated prior
Service Pump - Rigid
Structure with 1st RCF to start-up.
above 1150 CPM.
Generally vertical pumps must pass
through their structural critical speed
on ramp-up to full speed. The start-up
time for full voltage, across line start
induction motors to full speed is
approximately one second. The pass
through the structural critical speed
is so fast that there is no notice-
able vibration increase. However, a
VFD or SS/SS driven motor/pump
can build up significant vibration
when ramping excessively slowly
through its structural critical speed
range.

On occasions VFD’s and SS/SS


controllers are used to reduce
electrical in-rush surges to motors
during start-up by extending the
ramp-up time to full speed. Five
second acceleration to full speed
is usually long enough to
accomplish the reduced in-rush
with common squirrel cage induction
motors.

be subjected to considerable torque Pump shut-down can occur only Vertical pumps of the wet pit type
overload if this synchronization is not when the motorized valve is fully (figure 4) will backspin on shut down
followed. closed. The signal to shut down will when the water rushes downwards in
activate the motorized valve and the pump’s vertical column pipe. If it is
When starting high specific speed start it closing and once fully closed, not feasible to use a non-reverse
pumps, such as Mix Flow or Axial the motor must be electrically ratchet in this motor, a time delay to
Flow types, with high shut-off disconnected. Under no circum- prevent pump restart during a
horsepower, synchronization of the stances should the VFD or Soft Stop backspin is recommended. On long
valve opening time with the pump controller be allowed to run down the length deep setting pumps, backspin
ramp-up time is particularly important motor with out the valve being fully duration can range between four and
must and be carefully planned with closed. five minutes. However, on the normal
qualified personnel. wet pit pumps, with less than 50 ft to
the standing water level, the backspin
time rarely exceeds two minutes. ■
Summary
Pump shut-down
Usually pump ramp-up time to full CONTACT
Timing of the flow control valve speed should be as short as possible. Bill Beekman
Weir Floway inc
closure must also be carefully A five second ramp-up time is 2494 S Railraod
synchronized with pump shut down in recommended for the following Fresno CA 93706
order to prevent system backflow into reasons. On wet pit type VTP, MF USA
Email: billb@floway.com
the pump prior to the motor being and AF pumps that have product www.weirclearliquid.com
electrically disconnected. lubricated line shaft bearings that are
not pre-lubricated, it is advisable to
If the flow control valve is used to wet the bearings from pumped fluid as Bill Beekman. P.E. is Technical
Director at Weir Floway Inc. and
dampen pipeline surge on shutdown, soon as possible. Pump acceleration
has worked in the field of vertical
it must close prior to the pump being time must not, however, be delayed.
pump and corrosion resistance
shut down. This means the pump science and technology for
operates at shut-off head before It is also recommended that where 44 years.
electrical disconnection. liquid levels are in excess of 50ft.

22 www.worldpumps.com WORLD PUMPS November 2004